Military Engineer Services-MES has published Repair Replacement Maint Of Ceiling Fans Exhaust Fans Wall Fans Pedestal Fans And Water Heater Certain Point Wiring And Allied Works At Afs Kumbhirgram. Submission Date for this Tender is 13-08-2022. Electrification Work Tenders in kumbhirgram Assam. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 06-Aug-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-08-2022 |
Sl. No. | Item Description |
1 | Taking down carefully copper/ Aluminum point wiring (light, fan socket or power) complete incl. (fitting such as switches, ceiling roses, pendants, regulators, sockets, boards, DB, MCB, light fittings etc), removing materials from site and making good disturbed surfaces of walls, floors etc, complete all as specified and directed. |
2 | Material and labour for concealed point wiring for one light/ Fanpoint controlled by one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn through and including 20 mm dia (medium grade) non metallic PVC concealed conduit along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and includingpressed steel sunken boxes, having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm(concealed type) with 3mm thick bakelite sheet cover for mounting switches, sockets, fan regulators etc including testing on completion, including cutting chases for concealed conduit , making good the disturbed surfaces using cement mortar 1:3 complete all as specified and directed. |
3 | All as per Item No 2 here-in before but for one three pin switch socket outlet, 5 Amp on independent board complete all as specified and directed. |
4 | All as per item No 2 here-in before but for one 3 pin, 5 Amp socket point on the same board with other switch, complete all as specified and directed. |
5 | All as per item No 2 here-in before but for one 3/5 pin, 15 Amp switch socket combination on independent board with 2.5 sqmm PVC insulated unsheathedmultistranded FRLS copper conductor, complete all as specified and directed. |
6 | All as per Item No 2 here-in-before but for one light point controlled by two 2 way switch all as specified and directed. |
7 | All as per item No 2 here-in-before but for one bell point controled by one bell push on the same board with other switches or independent all as specified and directed. |
8 | Material and labour for point wiring (surface type) for one light/ Fan pointcontrolled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade in and including PVC capping and casing (double lock, ISI Marked) of suitable size with all necessary fittings along with 1.5 sqmm continuous PVC insulated unsheathed stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and including PVC rectangular switch board with plastic laminated sheet coverfor mounting switches, sockets, fan regulators etc including testing on completion complete all as specified and directed. |
9 | All as per Item No 8 here-in-before but for one switch socket outlet, 5 Amp on independent board all as specified and as directed. |
10 | All as per item No 8 here-in before but for one 3 pin, 5 Amp socket point on the same board with other switch, complete all as specified and directed. |
11 | All as per item No 8 here-in before but for one 3/5 pin, 15 Amp switch socket combination on independent board with 2.5 sqmm PVC insulated unsheathedmultistranded FRLS copper conductor, complete all as specified and directed. |
12 | All as per item No 8 here-in-before but for one bell point controled by one bell push on the same board with other switches or independent all as specified and directed. |
13 | All as per Item No 8 here-in-before but for one light point controlled by two 2 way switch all as specified and directed. |
14 | Supply and fix switch flush type, single pole 2 way 5 Amps 230 volts all as specified and directed. |
15 | M&L forsub main wiring with 2 run of single core 2.5 Sqmm FRLSH (ISI Marked) PVC insulated unsheathed multistranded copper conductor cable drawn through and including PVC Conduit/ casing capping of minimum size 32 mm alongwith accessories on roof/walls/ ceiling etc including one run of 2.5 Sqmm FRLSH (ISI Marked) PVC insulated unsheathed multistranded copper conductor as earth wire, including taking down old wiring, complete all as specified and directed. Note :- Two run of 2.5 Sqmm single core cable, one run of 2.5 Sqmm earth wireand one run of PVC conduit/ casing capping shall be measured as one run length. |
16 | M&L forsub main wiring with 2 run of single core 4.0 Sqmm FRLSH (ISI Marked) PVC insulated unsheathed multistranded copper conductor cable drawn through and including PVC Conduit/ casing capping of minimum size 32 mm alongwith accessories on roof/walls/ ceiling etc including one run of 4.0 Sqmm FRLSH (ISI Marked) PVC insulated unsheathed multistranded copper conductor as earth wire, including taking down old wiring, complete all as specified and directed. Note :- Two run of 4.0 Sqmm single core cable, one run of 4.0 Sqmm earth wireand one run of PVC conduit/ casing capping shall be measured as one run length. |
17 | M&L forsub main wiring with 2 run of single core 6.0 Sqmm FRLSH (ISI Marked) PVC insulated unsheathed multistranded copper conductor cable drawn through and including PVC Conduit/ casing capping of minimum size 32 mm alongwith accessories on roof/walls/ ceiling etc including one run of 6.0 Sqmm FRLSH (ISI Marked) PVC insulated unsheathed multistranded copper conductor as earth wire, including taking down old wiring, complete all as specified and directed. Note :- Two run of 6.0 Sqmm single core cable, one run of 6.0 Sqmm earth wireand one run of PVC conduit/ casing capping shall be measured as one run length. |
18 | Supply and fix Switch piano flush button single pole, one way 5 Amp, complete all as specified and directed. |
19 | Supply and fix Switch Socket combination 5-in 1 flush type 5 Amps 5pin, 230 volts complete all as specified and directed. |
20 | Supply and fix Switch socket combination 2 in 1,3 pin, 5 amps and 15 amps (ISI marked) flush type, universal shuttered, complete all as specified and directed. |
21 | Supply and fix call BellAC 230 Volts, single pole, complete all asspecified and directed. |
22 | Supply and fix bell push, flush type, 5 Amps, complete all as specified and directed. |
23 | Supply and fix Ceiling rose, 3 pole, PVC/polycarbonate, insulated body (ISI Marked) complete all as specified and directed. |
24 | Supply and fix Stepped type electronic fan regulator, AC 50 HZ, 230V,100 Watts, minimum 4 steps(ISI Marked), complete all as specified and directed. |
25 | Supply and fix LED tube light fittings 1 x 09/10 Watt two feets long with polycarbonate housing & intigrated electronic driver and necessary electric connection complete all as specified and as directed. |
26 | Supply and fix LED tube light fittings 1 x 18/20 Watt four feets long with polycarbonate housing & intigrated electronic driver and necessary electric connection complete all as specified and as directed. |
27 | Supply and fix wallmountedbulk headLED light fitting 10W, made up of poly carbonate housing with diffuser & intigrated electronic driver and necessary electric connection complet all as per specified and directed. |
28 | Supply and fix in repair Stepped type electronic fan regulator, AC 50 HZ, 230V,100 Watts, minimum 4 steps(ISI Marked) complete all as specified and directed. |
29 | Supply and fix in repair Switch piano flush button single pole, one way 5 Amp,complete all as specified and directed. |
30 | Supply and fix in repair Switch Socket combination 5-in 1 flush type 5 Amps 5pin, 230 volts complete all as specified and directed. |
31 | Supply and fix in repair Switch socket combination 2 in 1,3 pin, 5 amps and 15 amps (ISI marked) flush type, universal shuttered, complete all as specified and directed. |
32 | Supply and fix in repair call bellAC 230 Volts, single pole,complete all asspecified and directed. |
33 | Supply and fix in repair bell push, flush type, 5 Amps, complete all as specified and directed. |
34 | Supply and fix in repair Ceiling rose, 3 pole, PVC/polycarbonate, insulated body (ISI Marked) complete all as specified and directed. |
35 | S&F PVC rectangular/square switch board for mounting, switches, sockets, fan regulator etc. with cover of size 100 mm x 100 mm and 50 mm deep including taking down unserviceable board complete all as specified and directed. |
36 | All as per item No 35 here in before but size 175 x 100 x 50 mm |
37 | All as per item No 35 here in before but size 200 x 150 x 50 mm |
38 | All as per item No 35 here in before but size 250 x 200 x 50 mm |
39 | Supply and fix in repair PVC casing and caping of size 25mm complete all as specified and directed. |
40 | Supply and fix in repair PVC casing and caping of size 20mm complete all as specified and directed. |
41 | Supply and fix sheet metal enclosure MCB DB 8 waySPN double door suitable for 240 V, fixed flushed on walls including necessary wall cutting and making good disturbed surfaces and blanking plate as per requirement and taking down unserviceable DBs complete all as specified and directed. |
42 | Supply and fix sheet metal enclosure MCB DB 4 waySPN double door suitable for 240 V, fixed flushed on walls including necessary wall cuttingand making good disturbed surfaces and blanking plate as per requirement and taking down unserviceable DBs complete all as specified and directed. |
43 | S&F miniature circuit breaker (MCBs) SPN , 240 Volt, 32-40 Amps, "C" series,10 KA breaking capacity, complete all as specified and directed. |
44 | S&F MCB SP 240 Volts, "C" series, breaking capacity 10 KA of rating 6-32 Amps complete all as specified and directed. |
45 | REPAIR TO CEILING FANS WITH FOLLOWING ITEMS OF WORK :- M&L for Rewinding of Ceiling fan 1400 mm sweep after dismenting complete motor assembly, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/turn of super enamelled copper wire, heating, vernishing, replacement of unserviceable bearings / bushings, assemble of motor and statar unit with capacitor, connecting wire, down rod, blades and testing complete. Note: 1. Contractor shall collect fans from the complaint cells of specified area and bring back to complaint cell after repair. Cost of transportation will be inclusive of quoted rate. 2. Spares require for repair such as bearing, bushing, capacitor shall be measured and paid separately as supply only. 3. Cost of Connector bock and capacitor holder shall be inclusive of the quoted rate. |
46 | All as per item No. 45 here-in-above but for Ceiling fan 1200 mm sweep |
47 | All as per item No. 45 here-in-above but for Exhaust fan 450 mm sweep industrial type. |
48 | All as per item No. 45 here-in-above but for Exhaust fan 300 mm sweep industrial type. |
49 | All as per item No. 45 here-in-above but for Wall mounted fan 400 mm sweep domestic type. |
50 | All as per item No. 45 here-in-above but for Padestal fan 450 mm sweep domestic type. |
51 | Supply only ball bearing of No 6201/6202/6203/6204 of Make:SKF/Tata/NBC. |
52 | Supply only G.M. Bushing for ceiling fan as per existing pattern. |
53 | Supply only capacitor AC for 230 volts 50 Hz of capacity 1.8/2.0/2.25/2.5 Mfd. |
54 | Supply only capacitor AC for 230 volts 50 Hz of capacity 3.15/4.0 Mfd. |
55 | REPAIR TO STORAGE WATER HEATER COMPRISING OF THE FOLLOWING ITEMS OF WORKS :- S&FPVC insulated PVC sheathed copper flexiable wire multistrand 4sqmm 3 core, ISI marked |
56 | S&Fin repair thermostat ISI marked suitable for geysers 25 Ltrs to 50 Ltrs Capacity all as specified and directed.. Make- Bajaj/Venus/Recold |
57 | S&Fin repairfusible plug ISI marked suitable for 25 and 50 ltrs capacity Geysers all as specified and directed. |
58 | S&Fin repair heating element ISI Marked round/triangular bar, push type or thread type including rubber washers for 1.5/2.0 KWall as specified and directed. |
59 | S&Fin repair heavy duty PVC connection pipe suitable for storage water heater with brass hexagonal adopter both side, 15mm dia and 450mm long all as specified and directed. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy