Maintenance Of Electronic Installation & Fans, Street Light / Compound Light / Security Light, Air-Conditioning, Pump Set, Dg Set At Fire Station Connaught Place, Fire Station Rakaab Ganj & Chanakya Puri, New Delhi ( Sh:- Miscellaneous Electrica, New Delhi-Delhi

Public Works Department-PWD has published Maintenance Of Electronic Installation & Fans, Street Light / Compound Light / Security Light, Air-Conditioning, Pump Set, Dg Set At Fire Station Connaught Place, Fire Station Rakaab Ganj & Chanakya Puri, New Delhi ( Sh:- Miscellaneous Electrica. Submission Date for this Tender is 30-07-2022. Electrical Maintenance Tenders in New Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

33230880
Maintenance Of Electronic Installation & Fans, Street Light / Compound Light / Security Light, Air-Conditioning, Pump Set, Dg Set At Fire Station Connaught Place, Fire Station Rakaab Ganj & Chanakya Puri, New Delhi ( Sh:- Miscellaneous Electrica
Open Tender
Indian
Delhi
New Delhi
30-07-2022

Tender Details

Maintenance Of Electronic Installation & Fans, Street Light / Compound Light / Security Light, Air-Conditioning, Pump Set, Dg Set At Fire Station Connaught Place, Fire Station Rakaab Ganj & Chanakya Puri, New Delhi ( Sh:- Miscellaneous Electrical Works As And When Required ) .Uri Fire Station, New Delhi

Key Value

Document Fees
Refer document
EMD
INR 3629.0 /-
Tender Value
INR 1.81 Lakhs /-

BOQ Items

Name of Work: MOEI & Fans, Street Light/ Compound Light/ Security Light, Air-Conditioning, Pump Set, DG Set at Fire Station Connaught Place, Fire Station Rakaab Ganj & Chanakya Puri, New Delhi (SH:- Miscellaneous Electrical Works as and when required).
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (a) Group B
2(a) Group C
3Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
4(b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
5(c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
6Rewiring for light point/fan point/exhaust fan point/call bell point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 Sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel conduit including dismantling as required. (a) Group B
7(a) Group C
8Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 3 x 1.5 sq. mm
9(b) 3 x 4 sq. mm
10(c) 6 x 4 sq. mm
11Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
12Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
13Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (a) 5/6 A switch
14(b) 3 pin 5/6 A socket outlet
15(c) 15/16 A switch
16(d) 6 pin 15/16 A socket outlet
17Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 8 way, Double door
18Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) (a) 8 way (4 + 24), Double door
19Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole
20(b) Single pole and neutral
21Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 Amps
22Supplying, installation, testing & commissioning of 20 - 22 watt of 1200 mm long, 6500K energy efficient LED wall mounted light luminaries, extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver, suitable to work 230 volt AC supply complete with connection etc. with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. The luminaries shall be submitted with LM-80 report with a life of 50000 hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram, Edison.
23Supplying, installation, testing & commissioning of 15 watt recess mounted glarefree round LED downlight, system lumen efficancy 90Lm/W, cool day light (5700K to 6500K), power factor>0.90, CRI>80, LED lamp complete with all accessories, testing & commissioning etc. as required.
24Supplying, installation, testing & commissioning of energy efficient recessed mounted type 34W to 36W full window glare free opal diffuser LED panel luminaries of size 595mm x 595mm (nominal size)suitable for both Armstrong/POP/Geypsum Board or grid false ceiling fabricated with MS powder coated white CRCA housing including mounting with thehelp of chain/other suitable method, hanging from the ceiling including connections with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. The total system wattage not more than of 34W to 36W, LED lumen should be = 3600 system efficacy of = 110 lumen /watt colour temperature 5500K to 6500K, power factor>0.95, CRI (Ra)>80, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram, Edison.
25Supplying, installation, testing & commissioning of energy efficient LED flood light luminaries of system wattages 100 watt complete with mounting brackets and accessories on the street light pole with help of tower wagon including connections complete as required. The LED luminaries should confirm the following technical specifications:- a) Type of LED: High power LEDs Nichia / Osram / Cree / Philips b) driver efficiency >85% c) System Efficacy >110lm/w d) color Index(CRI) Ra>70 e) Color Temperature (CCT) Cool white: 4000°K f) Input Voltage. 140-270V AC g) Frequency Range 50-60Hz h) Power Factor(PF) > 0.95 i) Surge protection = 10KV j) Total Harmonic Distortion(THD)< 10% k) Working Environment 0°C to 50°C;10%-90%RH l) Working lifetime: >50000 hrs. m) IP Rating :- IP66 n) Housing and finish:-epoxy powder coated die cast aluminum housing with elegantly designed heat sink for efficient thermal management and to excellent corrosion resistant, cable gland P49 is provided at cable entry cover & high quality toughned glass.
26Supplying, installation, testing & commissioning of energy efficient following size ceiling fan, including wiring the down rod of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including providing and fixing phenolic laminated sheet cover on fan box etc. as required. (a) 1200 mm sweep size
27Supply and fixing of 400 mm sweep size wall mounted fan complete with inbuilt electronic regulator, blade, wire lead with moulded plug top etc. as required.
28Supplying and installation of heavy duty exhaust fan of following size, 900 rpm speed with shutter & louvers in the existing opening alongwith connection, testing & commissioning etc. as required. (a) 300 mm sweep size
29Supplying and fixing, fresh air fan of 250 mm sweep size suitable for 220 volts, 50 hz, A.C. supply, in the exisitng opening including, making the hole to suit the size of the above fan, making good the damages, connection, testing, commissioning etc as required.
30Supplying, laying and fixing of following size PVC insulated and PVC sheathed/ XLPE aluminum conductor armoured power cable of 1.1 KV grade in following manner etc. as reqd. (a) 4 x 25 sq.mm on wall surface
31(b) 3 x 16 sq.mm on wall surface
32(c) 3 x 6 sq.mm on wall surface
33Less credit of following electrical accessories etc. complete as required. (a) Light Fittings (assorted)
34(b) Ceiling Fans assorted size (assorted size)
35(c) Wall Fan (assorted size)
36(d) Exhaust Fan (assorted size)
37(e) Fresh Air Fan (assorted size)
38(f) Assorted material such as switch, socket, plate, wire, cable scrap iron, conduit, box etc.