Special Repair To Change In Old Cemented Pole With Steel Tubular Pole, Special Repair To Ber E / M Appliances And Provn Of Electric Cable For Ac In Smq Area At Area B Ph-Ii Af Stn Wadsar
Tender Overview
Project Description
Special Repair To Change In Old Cemented Pole With Steel Tubular Pole, Special Repair To Ber E / M Appliances And Provn Of Electric Cable For Ac In Smq Area At Area B Ph-Ii Af Stn Wadsar
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 03-Aug-2022 | Revised BOQ | BOQ | 12-Aug-2022 |
| 2 | 12-Aug-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 19-Aug-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down of existing serviceable street light from RCC Pole and refixing on steel tubular pole bracket after cleaningand connecting PVC wire till looping box complete all as specified and directed.Note:-PVC wire for connection will be measured and paid separately |
| 2 | Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 3 | Dismantling concrete pole/struts any size carefully to avoid any damage to nearby objects complete all as specified and directed. |
| 4 | Supply and errecting steel tubular pole in replacement ofRCC poles with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) duly painted internally complete and externally painted with two coat of aluminium paint complete all as specified and directed.Note: Earth work /excavation / PCC shall be measured and paid separately. |
| 5 | S&F in replacement of mounting bracket forming Cap type having an interior angle of 120 degree made out of GI pipe light grade 50 mm dia as per LED light required for fixing to street light fittings on the poles not less than 1.5 meter long duly painted with aluminium paint two coats complete all as specified and directed. |
| 6 | S&F in repair PVC wire 1.5 sqmm 3 Core PVC insulated cable copper drawnfrom looping box to street light fitting terminal complete all as specified and directed. |
| 7 | M & L for Writing letters or figures (Block.Roman, Italic or Indian) n exc. 30 cm high complete all as specified and directed. |
| 8 | S & F Radium sticker red colour water proof 80 mm wide around the poles complete all as specified and directed. |
| 9 | S&F in repair of looping box (enclosures) of size 280 x 170 x 130 mm made of PVC comprising of 02 Nos aluminium bus bar 100 Amps rating fixed on porcelain insulators, earthing terminal and one MCB SP 6 Amp including MS bracket, nut an bolts complete all as specified and directed. |
| 10 | M&L for excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc. and getting out soft/ loose soil complete all as specified and directed. |
| 11 | Returning, filling in including spreading, levelling, watering and well ramming in layer not exceeding 25cm complete all as specified and directed. |
| 12 | Removing excavated materials not exceeding 50 mtrs away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 13 | Supply and laying clean dry sand for cable cushioning including gently punning down complete all as specified and directed. |
| 14 | M&L for old size , burnt brick, sub class \"B\", laid in trenches, abutting each other with a gap not exceeding 10 mm , vertically over the cable for cable protection complete all as specified and directed. |
| 15 | Supply and laying or fixing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cable (H/D) earthed cable aluminium conductor, 1100 volts grade with standed complete all as specified and directed for 10 sq. mm, 2 core nominal cross section in service connections. |
| 16 | Taking up/down of old unserviceable UG LT cable up to 16 Sqmm, 2 core of any type from trenches etc complete all as specified and directed. |
| 17 | S&F 40 mm bore GI tubing, light grade galvanized with all fitting and laid in trenches complete all as specified and directed. |
| 18 | M & L for boring of holes up to 50 mm dia under road pavement, hard standing, etc by trench- less technology using ultra sound technique complete all as specified and directed by Engineer-in- charge.Note:- Pipe for protection of cable shall be measured and paid separately. |
| 19 | Supply and fixing GI pipe Light grade 50 mm bore (ISI marked) laid in trenches/ path /road crossings/ fixed to poles/ceiling/ along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required, complete all as specifiedand as directed by the Engineer-in-Charge. (Note:- Necessary excavation and earth work shall be measured and paid for separately) |
| 20 | M & L for boring of holes up to 80 mm dia under road pavement, hard standing, etc by trench- less technology using ultra sound technique complete all as specified and directed by Engineer-in- charge.Note:- Pipe for protection of cable shall be measured and paid separately. |
| 21 | Supply and fixingin repair GI tubing Light grade of 80 mm bore for cable protection in wall/trench complete all as specified and as directed by the Engineer-in-Charge. (Note:- Necessary excavation and earth work shall be measured and paid for separately) |
| 22 | M & L PCC 1:3:6 type C2 using 40 mm graded stone aggregate in foundation of pole complete all as specified and directed. |
| 23 | M & L PCC 1:3:6 type C1 using 20 mm graded stone aggregate in copingof pole etc including necessary form work complete all as specified and directed. |
| 24 | S&F in replacement Nature Switch complete pole mounted enclosure consisting of MCBs, Power Contactor and SMC Enclosure conforming to IP 54) for encasing full 1- phase circuit board along with Nature Switch-01,Model No SWADEEP – 02EC 3kW1P (for 3-5kW load equally distributed over 1-phase) complete all as specified and directed by Engr-in-charge. |
| 25 | M&L forearthing complete with galvanized steel earth plate electrode 600x600x6mm thick electrode, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to 4 mm dia galvanized earth wire by means ofbolts, nuts, check-nuts and washers of galvanized iron or steel all as shown in electrical plate No 5 (duly protected with 15 mm dia light grade GI pipe upto 7.5m from the earth plate) and connected to GI steel earth plate including charcoal, dust, common salt, necessary excavation in soft/loose soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m from the starting point, watering pipe 20 mm bore GI tube of light grade treated with 1 No PGI funnel, pit of PCC 1:2:4 type B-1/ RCC1:2:4 type B-1, pit cover 75 mm thick reinforced with 6 mm dia bars @ 75 mm c/c both ways and with MS handle 12 mm diaconnected to earth test point including testing complete all as specified and directed. |
| 26 | Supply, laying & testing cable XLPE insulated, screened ,PVC bendded galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade, of size 25 sq mm. 3.5 core complete all as specified and directed. |
| 27 | Supply, laying & testing cable XLPE insulated, screened ,PVC bendded galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade, of size 185 sq mm. 3.5 core complete all as specified and directed. |
| 28 | S & F MCCB 4 Pole 12 to 63 Amps, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and directed. |
| 29 | S & F MCCB 4 Pole 125 to 160 Amps, 50 Hz, 415 V with rupturing capacity 35 KA complete all as specified and directed. |
| 30 | S & F MCCB 4 Pole 160 to 200 Amps,50 Hz,415 V with rupturing capacity 35 KA complete all as specified and directed. |
| 31 | M&L for concealed sub main wiring of two run with 2.5 Sqmm single core PVC insulated, FRLS,flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit and accessories of suitable size and fixed on concealed surface of wall/ceiling with cutting chases where required including one run of 2.5Sqmm single core PVC insulated, FRLS ,flexible copper cable as earth continuity conductor in green color complete all as specified and directed. |
| 32 | S& F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed. |
| 33 | Supply and fixing SPN 32 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 34 | Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 150 KVA, Variac with Buck Boost transformer type Micro Controller based digital display Input : 3P MCCB with all Electronic tripping facility included first filling oil included upto required level complete all as specified and directed.Note:- (i) Rating 150 KVA, 3 Phase, 4 wire with bypass switch and phase sequence correction system(ii) Input Frequency Ranges : 47 Hz to 63 Hz(iii) Duty cycle :- 24x7 Hrs(iv) Suitability :- suitable for all power factor loads(v) Class of Insulation :- F Class (vi) Efficiency 97-99%(vii) Input/OutputTermination On Copper Bus Bar (viii) Drive Direct AC drive for fastest voltage correction and durability(ix) Controls All the three phases controlled individually for better voltage and load management on micro processor controlled digital display |
| 35 | S& F On load change over switch with sheet metal Enclosure 200 amp , 4 pole ,415 volt including necessary cable connections complete all as specified and directed. |
| 36 | Supplying and layingXLPE insulated, PVC sheathed, armoured, heavy duty, aluminium conductor LT, 1100 Volts grade of size 120 Sqmm 3.5 core cable, fixed on walls and trenches etc complete all as specified and directed. |
| 37 | Supply, install,commissioning and testingInvertor type 5 star rated air cooled split unit air conditioner electric driven single phase of capacity of 1.5 TR,Eco friendly refrigerant, hi wall split units indoor/outdoor unit complete with cordless remote control unit andauto restart facility, 100 % copper and stabilizer free operation, includingexcess copper tubing if required beyond the length supplied with AC unit and PVC conduit of 15mm dia not exceeding 2.5 mtr long for water drain and making good to disturbed surface with cement mortar ratio of 1:3 and testing complete all as specified and directed by Engineer-in-charge. Make : Voltas,Blue star, Hitachi, DaikinNote:- (i) Rate quoted for items includes cost of all civil work like cutting to wall ceiling, floor, filling with PCC,finishing the surfaces with existing to match etc, if required for installation of AC unit as directed. (ii) Required copper pipes for installtion shall be deemed to be included in the quoted rates (iii) Old item retrievedshall be removed deposited to the AGE E/M store , the cost of the dismantling transporting anddepositingshall bedeemed to beincludedin qouted rate |
| 38 | Supply and fix AC 230 volts steel body evaporative type desert cooler electric driven (single phase), having nominal air flow of capacity6000 CuM per hour with stranded 2.5 mtr length of power cable with 3 pin plug complete all as specified and directed.Make : |
| 39 | Supply and fixing ceiling fans complete with blades, down rods, electronicregulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 40 | Supply & fix Air Circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting complete all as specified and directed. |
| 41 | Schedule of Credit |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender