Providing, Fixing And Installation Of Internal External Electrification Work Of Administrative Laboratory Block At Kvk Shopian Skuast-Kashmir- 1 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulat, shopian-Jammu And Kashmir

Sher-E-Kashmir University Of Agricultural Sciences & Technology-SKUAST has published Providing, Fixing And Installation Of Internal External Electrification Work Of Administrative Laboratory Block At Kvk Shopian Skuast-Kashmir- 1 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulat. Submission Date for this Tender is 06-08-2022. Couplers Tenders in shopian Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

33213851
Providing, Fixing And Installation Of Internal External Electrification Work Of Administrative Laboratory Block At Kvk Shopian Skuast-Kashmir- 1 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulat
Open Tender
Indian
Jammu And Kashmir
shopian
06-08-2022

Tender Details

Providing, Fixing And Installation Of Internal External Electrification Work Of Administrative Laboratory Block At Kvk Shopian Skuast-Kashmir- 1 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( 5 / 6 Amps Switchwith Modular Plate Of Hager Or Legrand2 / 4 / 6 / 8 / 10 Way ) / Equivalent 2 Group C 3 Wiring For Light / Power Plug With 2 X 4 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit Along With 1 No. 4 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 4 Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frlspvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 5 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earth Wire 6 4 X 4 Sq. Mm + 2 X 4 Sq. Mm Earth Wire 7 2 X 10 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 8 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate And Switch Box Including Connections Including Modular Plate Etc. As Required 9 5 / 6 Amps Switch 10 3 Pin 5 / 6 Amp Socket Outlet 11 Supply, Installation, Testing And Commissioning Ing And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5 / 6 A Modular Socket Outlet And 5 / 6 A Modular Switch, Connections Etc. As Required. 12 Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate And Switch Box Excluding Modular Plate As Required 13 Supply, Installation, Testing And Commissioning Ing And Fixing Suitable Size G.I Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 15 / 16Amps Modular Socket Outlet And 15 / 16 Amps Modular Switch, Connection, Painting Etc. As Required. ( Switch 16Ax Insysta And 6 / 16A Glossy White With Modular Plate Of Hageror Legrand 2 / 4 / 6 / 8 / 10 Way And Face Plate ) / Equivalent 14 Supply, Installation, Testing And Commissioning Ing And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 15 Supply, Installation, Testing And Commissioning Ing And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 16 8 Way ( 4 + 24 ) , Double Door 17 Supply, Installation, Testing And Commissioning Ing And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Dpmcb ) , H 18 25 Amps 19 63 Amps 20 Supplying And Fixing 5 Amps. To 32 Amps.Rating240 Volts C Series, Miniature Circuit Breaker Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 21 Single Pole 22 Supply, Installation, Testing And Commissioningand Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete As Required. 23 Supply, Installation, Testing And Commissioning Ing, Installation And Testing Of 50 Mm Cu. Pipe Filled With Crystalline Conductive Mixture With Copper Strip Of Size 25 Mm X 5 Mm Of Length2 Mtr With Ecofriendly Backfill Compound 50 Kg. Earth Pit Chamber ( 300Mm X 300Mm ) With Ci Cover For The Above. Excavation And Refilling Included . 24 Providing And Fixing 25 Mm X 5 Mm Copper Strip In 40 Mm Dia. G.I Pipe Frl Earth Electrode Including Connection With Brass Nut , Bolt, Spring, Washer, Excavation And Refilling Etc. As Required. 25 Supply, Installation, Testing And Commissioningof Ip40 Led Fixture 18 W + / - 1 Wled Recessdownlighter Round Shape With Minimum System Lumen Efficacy Of 100 Lm / W With Pressure Die Cast Aluminium Housing And P.F.>0.95 , Thd<10% , Cct 5700K, Cri 80.The Led With Useful Life Of 50000 Hrs At L70.. The Input Voltage Range Shall Be 150V To 270V .Fixture Have Surge Protection 2Kv .Driver .Wipro Cat. No : Ld90-231-Xxx-65-Xx*** 26 Sitc Of Ceiling Fan, Capacitor Type Suitable For Low Voltage Operation Including Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sq.Mm Fr Pvc Insulated, Copper Conductor, Single Core Cable Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc As Required. 27 1200 Mm Sweep ( 5 Star ) 28 Supply, Installation, Testing And Commissioning Of Ac230 / 250 Volts, 50 Hzexhaust Fan With Louveres Of Following Sizes Including Connection Etc. Complete As Required . 29 300 Mm 30 225 Mm 31 Supply, Installation, Testing And Commissioning Ing, Installation, Testing And Commissioning Of Cubical Type Main Lt Panel Board Suitable For 415 V 3 Phase 4 Wire 50 Hz Ac Supply, Installation, Testing And Commissioningsystem Including Incomers, Out Goings, Bus Bars, Interlocking Etc. As Required As Per The Following Description. ( Ip:42 ) Size 900X900x425mmwith Angle Iron Stand Etc Incomerthermal Magneticbased Mccb 160 Amps Fp Icu=Ics=100% With Breaking Capacity 50 Ka ( 01 Nos ) Indicating Lamps Ryb ( 1 Set ) Current Transformer 100 / 5 A 10 Va Burden, Class-1 ( 1 Sets ) Aluminium Busbar 300 Amps Fp E-91 E Grade Electrolytic Aluminiumoutgoingsthermal Magnetic Based Mcb 125 Amps Fp Icu=Ics=100% With Breaking Capacity 36 Ka ( 01 Nos ) Bye Pass Changeover 100 Amp = 1 Noindicating Lamps On Off Trip Load Bearing Members To Be Made Out Of 2.0 Mm Crca Sheet.Partitions To Be Made Out Of 1.6 Mm Crca Sheetgland Plates To Be 3.0 Mm Thick. 32 Supply, Installation, Testing And Commissioning Ing And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc. In The Existing Trench, Complete As Required. 33 150 Mm Dianominal ) 34 Supply, Installation, Testing And Commissioning Ing And Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Groundin Existing Dwc Pipe Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. 35 3.5 C X 95 Sq.Mm A2xfy 36 Supply, Installation, Testing And Commissioningand Making End Termination With Brass Compression Gland And Aluminium Lugs For The Following Sizes Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required ( Comet ) 37 3½ X 95 Sq. Mm ( 45Mm ) 38 Supply, Installation, Testing And Commissioning , Transportation, Unloading , Installation, Testing & Commissioning Of The Following Rating Of Ups System With Inbuilt Isolation Transformerincluding Unloading, Transportation From Store To Site , Errection Instllation, Testing Of Ups System Including Battery And Battery Rack Errection & Installation Under The Supervision Of Supplier Of Ups. Note:- Contractor Has To Submit The Drawings & Battery Selection Detail Before Procurement.Specification Of Ups System Shall Be Provided With Static By Pass And Maintenance By Pass Facility With Distribution Board . 39 10 Kva Ups , Input 3 Phase 4 Wire And Output 3 Phase 4 Wire With 120 Min. Back Up 40 Supply, Installation, Testing And Commissioning Ing And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required 41 Rj 45 Socket 42 Supply, Installation, Testing And Commissioning Ing And Fixing Of Following Sizes Of Pvc Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 43 25Mm Pvc Conduit 44 Supply, Installation, Testing And Commissioning Ing And Drawing Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 45 1 Run Of Cable 46 Supply, Installation, Testing And Commissioning , Installation, Testing And Commissioningofsemi Managed 16 Port Poe , Complete As Per Specification And As Desired By Eic. 47 Supply, Installation, Testing And Commissioning &Erectionoflockable9 / 12 Urackwith5astripand Twofanfordistribution, Mountingofpatchpanels, Hubs, Switches Etc, , Complete As Per Specification And As Desired By Eic. 48 Supply, Installation, Testing And Commissioning& Erection Of Cat-6, 1Mtr Patch Cordscomplete As Per Specification And As Desired By Eic. 49 S / I Of Geyser 50 Ltr Racold / Havells / Venus 50 Supply / Installation Of Mirror Light Fitting Havelll’S / Philps / Led Slim Type 4 Ft With Tube Etc 51 S / I Of Ip 65 Flood Lightjeta Ne 70 Cat No: Jetaneofl70wled757ltg Or Euivalent In Philips / Cg 52 P / F Of Street Lighting Luminaries With Single Piece Pot Make Philips / Syska / Havells 120 Watt Ledreflector Type & Uv Stabilized Acrylic Cover .Complete Job. 53 P / L Of 4 Mm Multi Stranded 3 Core Cable Make Havells / Gloster / Finolex / Khaitanwith Pvc Conduit 25Mm Dia , 2Mm Thick Prince B Type Pipe Etc With Earth Work And Excavation Job 2 Ft Depth X 9” Wide . With Refilling Job Etc 54 P / L Of 25 Mmaluminium Multi Stranded 1 Core Cable Make Havells / Gloster / Finolex / Khaitanwith Pvc Conduit 50 Mm Dia , 2Mm Thick Prince B Type Pipe Etc With Earth Work And Excavation Job 2 Ft Depth X 9” Wide . With Refilling Job Etc 55 Providing & Fixing Of Hot Dip Galvanized Octagonal Pole 8 Mtr Long With Following Dimensions :Length Of Pole 08 Mtrs.Bottom Dia 150 Mm Top Dia. 76 Mm Sheet Thickness : 3 Mm With Base Plate 240 X 240 X 16Mm Bolt Size = 20 Mm X 600 Mm X 4 No’Smake Philips / Bajaj / Equivalent 56 P / F Of Detachable Type Single / Doublearm Bracket Fabricated Out Of 40 Mm Dia Ms Pipe 1500Mm Long Duly Bended C Curve ( Hot Galvanised ) 57 P / F Of Mcb Box Ssk With Mcb Sp 10 A Legrand With Connector 40 A 4 Way With Clamp Nuts And Bolts & Washers Etc 58 P / F Of Mcb Dp 63 A Legrand With I / O Sockets Etc 15 / 5 A 59 Providing Fixing Of Concrete Block M-15 Mix 20Mm Nominal Aggregate Size 4 Nos. Holding Down Bolts Of Size 20 Mm X 600 Mm X 4 No’S Each Bolt Having 2 Nos.Nuts Below Washers To Be Adjusted With Plate Level For Hosting Of Octagonal Pole Under Sight Of Concrete All Nuts And Bolts Exposed To Be Applied With Grease With Block Dia 1’.X9’’3 Feet Deep For Steel Pole. The Finishing Work Includes Painting With Bitumen As Required 60 P / F Of 1.5 Sq Mm Pvc Multi Strandedcopper Wire From Connection Box To Luminary 61 Note:-The Rates Quoted Are Inclusive Of All Carriages Of Materials ( Mechanical / Manual ) From Source To Site Workand All Extra Charges Including Dewatering If Any During The Execution Of Work Complete In All Respects.

Key Value

Document Fees
INR 1000 /-
EMD
Refer document
Tender Value
INR 17.68 Lakhs /-

BOQ Items

Name of Work:- Providing, Fixing & Installation of Internal/ external electrification work of Administrative/ laboratory block at KVK Shopian SKUAST-Kashmir
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (5/6 amps switchwith modular plate of Hager or Legrand2/4/6/8/10 way)/Equivalent
2Group C
3Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required.
4Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.
52 X 2.5 SQ.MM + 1 X 2.5 SQ.MM Earth Wire
64 X 4 sq. mm + 2 X 4 sq. mm earth wire
72 X 10 sq. mm + 1 X 6 sq. mm earth wire
8Supplying and Fixing following modular switch/socket on the existing modular plate and switch box including connections including modular plate etc. as required
95/6 amps switch
103 Pin 5/6 amp socket outlet
11Supply,Installation,Testing and Commissioning ing and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
12Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
13Supply,Installation,Testing and Commissioning ing and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required.(switch 16AX insysta and 6 / 16A glossy white with modular plate of Hageror Legrand 2/4/6/8/10 way and face plate) / equivalent
14Supply,Installation,Testing and Commissioning ing and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
15Supply,Installation,Testing and Commissioning ing and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
168 way (4 + 24), Double door
17Supply,Installation,Testing and Commissioning ing and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (DPMCB),h
1825 Amps
1963 Amps
20Supplying and fixing 5 amps. to 32 amps.rating240 volts "C" series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
21Single Pole
22Supply,Installation,Testing and Commissioningand Fixing Single Pole Blanking Plate in the Existing MCB DB complete as Required.
23Supply,Installation,Testing and Commissioning ing,Installation and Testing of 50 mm Cu. Pipe Filled with Crystalline conductive Mixture with Copper Strip of Size 25 mm x 5 mm of Length2 mtr with Ecofriendly Backfill Compound 50 Kg. Earth pit chamber (300mm x 300mm) with CI cover for the above. excavation and refilling included .
24Providing and Fixing 25 mm x 5 mm Copper Strip in 40 mm dia. G.I Pipe FRL Earth Electrode including connection with Brass nut ,bolt,spring,washer,excavation and refilling etc. as required.
25Supply,Installation,Testing and Commissioningof IP40 led fixture 18 W +/- 1 WLED RecessDownlighter Round Shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Housing and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .Fixture have Surge Protection 2kV .Driver .Wipro Cat. No : LD90-231-XXX-65-XX***
26SITC of Ceiling Fan,Capacitor type suitable for low voltage operation including wiring the down rods of standard length(Upto 30 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required.
271200 MM SWEEP(5 STAR)
28Supply,Installation,Testing and Commissioning of AC230/250 Volts, 50 Hzexhaust fan with louveres of Following Sizes including connection etc. complete as required .
29300 mm
30225 mm
31Supply,Installation,Testing and Commissioning ing,Installation,Testing and Commissioning of Cubical Type Main LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply,Installation,Testing and CommissioningSystem including Incomers,Out Goings,Bus Bars,Interlocking etc. as required as per the Following Description.(IP:42) Size 900x900x425mmwith angle iron stand etc INCOMER Thermal MagneticBased MCCB 160 Amps FP Icu=Ics=100% with Breaking Capacity 50 KA (01 Nos) Indicating Lamps RYB (1 Set) Current Transformer 100/5 A 10 VA Burden, Class-1(1 sets) Aluminium Busbar 300 Amps FP E-91 E Grade Electrolytic Aluminium OUTGOINGS Thermal Magnetic Based MCB 125 Amps FP Icu=Ics=100% with Breaking Capacity 36 KA (01 Nos) Bye pass changeover 100 Amp = 1 No Indicating Lamps ON OFF TRIP Load Bearing Members to be made out of 2.0 mm CRCA Sheet. Partitions to be made out of 1.6 mm CRCA Sheet Gland Plates to be 3.0 mm Thick.
32Supply,Installation,Testing and Commissioning ing and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
33150 mm dianominal)
34Supply,Installation,Testing and Commissioning ing and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required.
353.5 C X 95 Sq.mm A2XFY
36Supply,Installation,Testing and Commissioningand Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet)
373½ X 95 sq. mm (45mm)
38Supply,Installation,Testing and Commissioning , transportation,Unloading , installation,testing & Commissioning of the following rating of UPS System with inbuilt isolation Transformerincluding unloading,transportation from store to site ,errection instllation,testing of UPS System including Battery and Battery rack errection & Installation under the supervision of supplier of UPS. Note:- Contractor has to submit the drawings & battery selection detail before procurement.Specification of UPS system shall be provided with Static by pass and Maintenance by pass facility with distribution board .
3910 KVA UPS , Input 3 Phase 4 wire and output 3 phase 4 wire with 120 min. Back up
40Supply,Installation,Testing and Commissioning ing and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
41RJ 45 Socket
42Supply,Installation,Testing and Commissioning ing and Fixing of Following sizes of PVC Conduit along with Accessories in surface/Recess including painting in case of surface conduit,cutting the wall and making good the same in case of recessed conduit as required.
4325mm PVC Conduit
44Supply,Installation,Testing and Commissioning ing and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
451 run of cable
46Supply,Installation,Testing and Commissioning , Installation, Testing and CommissioningofSemi managed 16 port POE , complete as per specification and as desired by EIC.
47Supply,Installation,Testing and Commissioning &Erectionoflockable9/12 Urackwith5Astripand twofanfordistribution,mountingofpatchpanels,hubs, switches etc,, complete as per specification and as desired by EIC.
48Supply,Installation,Testing and Commissioning& Erection of Cat-6, 1Mtr Patch Cordscomplete as per specification and as desired by EIC.
49S/ I of geyser 50 Ltr Racold /havells/Venus
50Supply /installation of Mirror light fitting Havelll’s /Philps/ LED Slim type 4 ft with tube etc
51S/I of IP 65 flood lightJeta Ne 70 CAT No: JETANEOFL70WLED757LTG or euivalent in Philips /CG
52P/f of street lighting luminaries with single piece POT Make Philips/Syska/Havells 120 Watt LEDreflector type & UV stabilized acrylic cover .Complete job.
53P/L of 4 MM multi stranded 3 core cable Make Havells/ Gloster/ Finolex/ Khaitanwith PVC conduit 25MM dia , 2mm thick Prince B type pipe etc with earth work and excavation job 2 ft depth x 9” wide . with refilling job etc
54P/L of 25 MMAluminium multi stranded 1 core cable Make Havells/ Gloster/ Finolex/ Khaitanwith PVC conduit 50 MM dia , 2mm thick Prince B type pipe etc with earth work and excavation job 2 ft depth x 9” wide . with refilling job etc
55Providing & fixing of Hot dip galvanized octagonal pole 8 mtr long with following dimensions :Length of pole 08 mtrs.Bottom Dia 150 MM Top dia. 76 MM Sheet thickness : 3 MM With base plate 240 x 240 x 16mm Bolt size = 20 MM x 600 MM x 4 No’sMake Philips/Bajaj/Equivalent
56P/f of detachable type single / doublearm bracket fabricated out of 40 MM dia MS Pipe 1500MM long duly bended C curve(Hot galvanised)
57P/f of MCB Box SSK with MCB SP 10 A Legrand with connector 40 A 4 Way with clamp nuts and bolts & washers etc
58P/ f of MCB DP 63 A Legrand with I/O sockets etc 15/5 A
59Providing fixing of concrete block M-15 mix 20mm nominal aggregate size 4 Nos. holding down bolts of size 20 MM x 600 MM x 4 No’s each bolt having 2 Nos.nuts below washers to be adjusted with plate level for hosting of octagonal pole under sight of concrete all nuts and bolts exposed to be applied with grease with block dia 1’.x9’’3 feet deep for steel pole. The finishing work includes painting with bitumen as required
60P/f of 1.5 Sq MM PVC Multi strandedcopper wire from connection box to luminary
61Note:-The rates quoted are inclusive of all carriages of materials (Mechanical/Manual) from source to site workand all extra charges including dewatering if any during the execution of work complete in all respects.