Bids Are Invited For Electrification work at Dr. Shayama Prasad Mukharjee (Civil) Hospital, Hazratganj, Lucknow -1 Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit on surface with , Lucknow-Uttar Pradesh

Uttar Pradesh Housing And Development Board has published Bids Are Invited For Electrification work at Dr. Shayama Prasad Mukharjee (Civil) Hospital, Hazratganj, Lucknow -1 Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit on surface with . Submission Date for this Tender is 01-08-2022. Storage Chests and Cabinets and Trunks Tenders in Lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33212055
Bids Are Invited For Electrification work at Dr. Shayama Prasad Mukharjee (Civil) Hospital, Hazratganj, Lucknow -1 Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit on surface with
Tender
Indian
Uttar Pradesh
Lucknow
01-08-2022

Tender Details

Bids Are Invited For Electrification work at Dr. Shayama Prasad Mukharjee (Civil) Hospital, Hazratganj, Lucknow -1 Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit on surface with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. [UPPWD SOR : 2018, 121 (C) + 187 (A)] 2 Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush type universal modular socket switch on concealed M.S box including supply of all material, labour T&P etc. required for proper completion of work. [UPPWD SOR : 1139 (A)] 3 Wiring Point for plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit on surface with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. [UPPWD SOR : 2018, 124 (C) + 187 (C)] 4 Supply and wiring of submain with two number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20mm dia. heavy duty (2mm thick) PVC conduit on surface with one number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit. [UPPWD SOR : 1301 (C)] 5 Supply and wiring of submain with two number 4 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20mm dia heavy duty (2mm thick) PVC conduit on surface with one number 2.5 sq. mm. multistrand copper conductor cable as earth continuity wire drawn in conduit. [UPPWD SOR : 2018, 211 (C)] 6 Supply and wiring of submain with Four number 10 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 32 mm dia heavy duty (2 mm thick ) PVC conduit on surface with two number 6 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. [UPPWD SOR : 2018, 268 (C)] 7 Supplying and drawing of UTP 4 pair CAT 6 in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable. [DSR : 2018, 1.53.2] 8 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm [DSR : 2018, 1.21.2] 9 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. i 120 sq. mm 3-1/2 core [UPPWD SOR : 2018, 501 (o)] ii 70 sq. mm 3-1/2 core [UPPWD SOR : 2018, 501 (m)] iii 50 sq. mm 3-1/2 core [UPPWD SOR : 2018, 501 (l)] iv 16 sq. mm 4 core [UPPWD SOR : 2018, 501 (i)] 10 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer- Incharge. i 120 sq. mm 3-1/2 core [UPPWD SOR : 2018, 503 (o)] ii 70 sq. mm 3-1/2 core [UPPWD SOR : 2018, 503 (m)] iii 50 sq. mm 3-1/2 core [UPPWD SOR : 2018, 503 (l)] iv 16 sq. mm 4 core [UPPWD SOR : 2018, 503 (i)] 11 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. i 120 sq. mm [UPPWD SOR : 2018, 504 (J)] ii 70 sq. mm [UPPWD SOR : 2018, 504 (h)] iii 50 sq. mm [UPPWD SOR : 2018, 504 (g)] iv 35 sq. mm [UPPWD SOR : 2018, 504 (f)] v 25 sq. mm [UPPWD SOR : 2018, 504 (e)] vi 16 sq. mm [UPPWD SOR : 2018, 504 (d)] 12 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. i 100 mm width x 50 mm depth x 1.6 mm thickness [DSR : 2018, 4.1.2] 13 Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. [UPPWD SOR : 2018, 811(a)] i Incoming 100 Amp. MCCB-1 No Outgoing 63 Amp. MCCB-2 Nos. Cat. B.Pannel Cubicle Type [UPPWD SOR : 2018, 811(a)] ii Incoming 400 Amp. MCCB-1 No Outgoing 100 Amp. MCCB-3 Nos. 63 Amp. MCCB-2 Nos. Cat. B.Pannel Cubicle Type [UPPWD SOR : 2018, 813(e)] 14 Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Starter control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects.The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. Star Delta Starter Suitable upto 10 HP Motor 15 S & F surface/Flush mounting 12ways TPN distribution board with additional metal door with MCB complete in all respect,as directed at site by Engineer in charge. (1 No. 63A 4P MCB as Incomer, 36 Nos. 6-32A SP MCB as Outgoing & 12 Way DB) [UPPWD SOR : 2018, 1029 (A) + 1017 + 1002] 16 Supply, Installation, Testing & Commissioning of 20 KVA Capacity 3 Ph input & 1 Ph Output with 30 Min Backup UPS complete with all accessories. 17 Supply and burring of Safe Earthing Electrode T-39 (Hot-Dip Galvanized), Length up to 3000mm, outer pipe 76mm inner Dia 38mm terminal Dia 12 mm ,outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. framevwith hinged cover & masonary housing. (From electrode terminal to switch board, cost of 25 X 3 GI. Strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. [UPPWD SOR : 2018, 725 (D)] 18 Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. [UPPWD SOR : 2018, 716] 19 Supply, installation, balancing and commissioning of fabricated at site Aluminium sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. i Thickness 0.80 mm sheet (22G) 20 Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class O) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. i 19 mm [DSR : 2018, 16.23.1] 21 Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. [DSR : 2018, 16.13] 22 Supply, Installation, Testing & Commissioning of Flexible Canvass Connection to connect the Air Handling Unit & Supply and Return Air Duct as per specification & complete in all respect. 23 Area Zonal Valve box for required a services as per ISO 7396 standard. Having Isolation valve, pressure gauge, locking arrangement, transparent breakable front to break in case of emergency.Uit must be manufactured as per CE and ISO 13485 certiying facility as per specification and approved make by UP Govt. Health Dept.. i 6 Services (Oxygen, Nitrous, Air-4, Air-7, AGSS/CO2, Vaccum, ) 24 Copper Piping : Copper pipes for medical Gases, Complete with elbows, flanges, Specials, others fittings, ad steel supports, The coper pipe should be of solid drawn seamless deoxidized un-arsenical tempered and of degreased material conforming to BS-EN 13348/ASTM 8819 of copper pipe must be certified and inspected by third party inspection agency like LLoyds/SGS/TUV etc. As per approved make attached. i 15 mm OD ii 22 mm OD iii 28 mm OD 25 Floor/Area Isolation valve-All valves are to e ball valves type and PTFE or teflon seals, They Shall be suitabke for a working pressure of 10.2 kg/cm2 gauge. Valves shall be fitted into the pipeline by means of capillary hard soldered joints containing silver. it should be open/close with help of handle with rotation of 90 degree. as per approved make attached. i 22 mm ii 28 mm Total Quantity : 1

Key Value

Document Fees
Refer document
EMD
INR 60000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail