Repairing, providing and fitting of Automatic Medical gas Manifold panels alongwith allied items in Main Hospital of SKIMS
Tender Value
6 Lakhs
Estimated cost
Bid Submission
30 Jul 2022
0 days left
EMD
12000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
soura → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repairing, providing and fitting of Automatic Medical gas Manifold panels alongwith allied items in Main Hospital of SKIMS
BOQ
| Sl. No. | Item Description |
| 1 | Repairing oxygen manifold of ward block of Main Hospital by way of providing and fitting of New automatic Medical gas manifold panel(Fully Automatic) for twin bank type (15+15) configuration with auto regulation, 02 No by-pass emergency kits/points regulator, lead (high pressure pipes),gauges, interconnecting copper piping, tail pipes with NRV for cylinders, Isolation control valve on the supply line including MS support and allied items. The manifold control panel shall be capable of regulating minimum 1500 LPM Oxygen flow and shall be designed with standing the oxygen cylinder pressure in the range of 0-200kgf/cm2 with safety features related to hazard and continuity of flow of medical grade oxygen. The panel shall operate at a constant pressure throughtwo banks of bottled gas cylinders with following status and indication system.(i)Bank in use:- Green Indication (ii)Bank ready for use :- yellow indication(iii).Empty Bank :- Red indicationThe Control panel shall have built-in LED display to indicate normal, high and low line-pressure. The Control panel shall incorporate safety provision in case of failure of electronic as well aspneumatic system. Control should be able to beused manually through by pass system. The mounting angle iron of 50x50x5mm shall be fixed on the wall with clamps/dash fasteners to hold the 15+15 cylinder system in place. The job includes dismantling, removing of old panel and cleaning of surface. The job includes cleaning of exiting old panel and stacking same at same place as per instruction of site Engineer. All wiring, thimbling, piping, valves etc required for successfully installation testing and commissioning of the battery bank are to be provided by the contractor. The equipment shall conform to the relevant ISO/BIS standard and contractor or firm shall have to submit relevant test certificates. |
| 2 | Repairing Medical gas manifold ( Nitrous oxide) of main hospital by way of providing and fitting of New automatic Medical gas manifold panel(Fully Automatic) suitable for line pressure range 0 to 10kgf/ cm2, twin bank type (10+10) configuration with auto regulation, 02 No by-pass emergency kits/points regulator, lead (high pressure pipes),gauges, interconnecting copper piping, tail pipes with NRV for cylinders, Isolation control valve on the supply line including MS support and allied items. The manifold control panel shall be capable of regulating minimum required Nitrous oxide, flow and shall be designed to bear the cylinder pressure of 0-200kgf/cm2 with safety features related to hazard and continuity of flow of medical grade Nitruous oxide . The panel shall operate at a constant pressure throughtwo banks of bottled gas cylinders with following status monitoring and indication system.(i)Bank in use:- Green Indication (ii)Bank ready for use :- yellow indication(iii).Empty Bank :- Red indicationThe Control panel shall have built-in LED display to indicate normal, high and low line-pressure. The Control panel shall incorporate safety provision in case of failure of electronic as well aspneumatic system. Control should be able to beused manually through by pass system. The mounting angle iron of 50x50x5mm shall be fixed on the wall with clamps/dash fasteners to hold the 15+15 cylinder system in place. The job includes dismantling, removing of old panel and cleaning of surface. The job includes cleaning of exiting old panel and stacking same at same place as per instruction of site Engineer. All wiring, thimbling, piping, valves etc required for successfully installation testing and commissioning of the battery bank are to be provided by the contractor. The equipment shall conform to the relevant ISO/BIS standard and contractor or firm shall have to submit relevant test certificates. |
AI Tender Summary
Tender Timeline
Jul 22, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedJul 30, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 01, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender