Repair To Security Wall, Compound Wall, Security Fencing, Path / Hardstanding And Certain Misc Works In Tech Area At Mil Stn Dappar Under Ge ( P ) Dappar
Tender Overview
Project Description
Repair To Security Wall, Compound Wall, Security Fencing, Path / Hardstanding And Certain Misc Works In Tech Area At Mil Stn Dappar Under Ge ( P ) Dappar
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-Aug-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 20-Aug-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of brick work built in cement mortar incl all quoins, arches, pillars, etc complete all as specified and directed by Engr-in-Charge. |
| 2 | M&L Brick work with sub class \"B\" burnt bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed by Engr-in-Charge. |
| 3 | M&L Brick work with sub class \"B\" burnt bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 but except brick complete all as specified and directed by Engr-in-Charge.(serviceble Old bricks shall be reused after cleaning obtained from demolition). |
| 4 | M&L Cement concrete 1:2:4 type B1 as in coping complete all as specified and directed by Engr-in-Charge. |
| 5 | Taking down cement plaster from brick wall including raking out joints ,hacking for key scrubbing down with water complete all as specified and directed by Engr-in-Charge. |
| 6 | Raking out joints/ pointing to brick work or brick tiles, laid flat, in floorsbuilt in cement mortar, surface channels, roofs, etc complete all as specified and directed. |
| 7 | M&L Keyed pointing to brick wallsin CM 1:4 complete all as specified and directed. |
| 8 | M&L for cement plastering 15mm thick in two layers (10mm and 5mm respectively) in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturer\"s instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and fair complete all as specified and as directed by Engineer-in-Charge. Note : WPC will be measured and paid separately. |
| 9 | Supply only integral liquid water proofing compound complete all as specified & as directed by Engineer-in-Charge. Make : Pidilite/Sika |
| 10 | M & L for preparing new surface of external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc including cornices and applying two coat of cement base paint @ 5 sq.m/kg/1 coat by using following brands of cement based paint by roller complete all as specified & as directed by Engineer-in-Charge.Make of Cement Paint : Snowcem Plus (Snowcem Paints) |
| 11 | Dismantling posts or struts (wood, R.C.C or steel.) any section, including taking out embedded portion and making good disturbed ground to facilitate provison for embedding of new post complete all as specified and as directed. |
| 12 | M&L for ecavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/loose soil |
| 13 | M&L Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters,nosingtosteps includingembedinginconcrete and screwing etc. wind ties for roofincluding securing boltsposts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling,boltingor riveting, etc., and similar work conforming to Fe-290 Gde E-165as directed and fixed |
| 14 | M&L Cement concrete type D2 1:4:8 (using 40mm graded stone aggregate) in foundations, filling and mass concrete andfor embedding posts (including caps and bases) complete all as specified and as directed. |
| 15 | Dismantlingof old barbed wire and making rolls including stacking neatly complete all as specified and directed by Engr-in-Charge. |
| 16 | Fixing only chain link fencing including line wires, any mesh, size and type to any typeof standards, rails, straining bolts, etc. including provission of binding wirecomplete all as specified. |
| 17 | Supply only chain link fencing made out of 3.15mm dia galvanised iron wire of mesh 50mmx50mm size ,made upto into mattress or cages complete all as specified. |
| 18 | S/F mild steel round bar 10 mm diacut to length bend to shape required including cranking binding hooking as requiredfor chain link fencing , for tie bar strenghting and fixing with nut bolt in fencing post allas specified. |
| 19 | S&Fmild steel screw bolt 5 to 10 mm dia (machine made) with hexagonal head at one end and screwed the other, screwed end to be fitted with one waher and hexagonal nut lengthexc 5cm but not exc 10 cm long. |
| 20 | S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at75mm spacings and straining and fixing to any type of standard rails strainingbolts, including, securing or tying at crossings with and provision of galvanised mildsteel wire, staples or steel pins, etc. as directed (eachline wire to be measured) ® |
| 21 | Restraining and re-securing barbed wire fencing including making good staples etc complete all as specified and directed by Engr-in-Charge. |
| 22 | Preparation of newly or previously untreated steel surfaces, of any description, over 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 23 | Demolition of reinfoced cement concrete of any description and in any position not otherwise specifically demolition provided for(reinfocement should be cut as required to facilitate demolition) complete all as specified and directed by Engr-in-Charge. |
| 24 | M&L reinforced cement concrete (nominal mix) type B1 1:2:4 (using 20 mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed by Engr-in-Charge |
| 25 | M&L reinforced cement concrete (nominal mix) type B0 1:2:4 (using 20 mm graded aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and as directed by Engr-in-Charge |
| 26 | M&L Mild steel TMT bar 10mm dia and over, cut to length, bent to shape required including cranking bending spirally for hooping for column, hookingends and binding with and including mild steel wire (annealed ) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge. |
| 27 | M&L Mild steel TMT bar 5 mm dia and over upto and including 10 mm dia in stirrups, spaces and binders, cut to length, bent to shape required including cranking bending spirally hooping for column, hookingends and binding with and including mild steel wire (annealed ) not less than 0.9mm dia or securing with clips quality conforming to, as in stirrups, spaces and binders complete all as specified and directed by Engr-in-Charge. |
| 28 | Formwork to sides and soffits of floor or roof beams, beam haunch- ings, girders, bressummers, lintels, cantilevers, shelves including sup• ports, overhangs, etc. also splays between floors and beams, etc.for fair finishedflat surfacecomplete all as specified and directed by Engr-in-Charge. |
| 29 | Form work to sides of pillars, post, struts, piers, columns and stanchions , complete all as specified and directed by Engr-in-Charge. |
| 30 | Dismantling wrought iron or mild steel work of any description not otherwise provided for angle iron or flat iron as in post and guard bar or grating complete all as specified and directed by Engr-in-Charge. |
| 31 | S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe -290 Gde E-165 complete all as specified and directed by Engr-in-Charge. |
| 32 | Demolition of cement concrete (unrenforcement)in ground floors not exc 15 cm in thickness (below or above ground level), complete all as specified and as directed. (Note : All the demolished material will be disposed off outside the MOD land). |
| 33 | M&L 100 mm thick Cement concrete type D2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing. |
| 34 | M&L Sand filling 25mm thick under floors or in foundations including watering and consolidation complete all as specified & directed. |
| 35 | M & L machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and no pigmentas specified & as directed by Engr-in-Charge. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender