Housing Urban and Rular Development Government Departments Closing in 0 days TDR #33190959

General-Replacement Of Damaged Cable And Starter For Submersible Motor At Munsiff Court, Adoor-Repairs Of Submersible Motor-General Electrical Work General-Replacement Of Damaged Cable And Starter For Submersible Motor At Munsiff Court, Adoor-Repairs Of

Issued by Government Departments · adoor, Kerala
Tender Value
56452
Estimated cost
Bid Submission
29 Jul 2022
0 days left
EMD
1411
Bank guarantee accepted
Document Fee
555
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
adoor → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

General-Replacement Of Damaged Cable And Starter For Submersible Motor At Munsiff Court, Adoor-Repairs Of Submersible Motor-General Electrical Work General-Replacement Of Damaged Cable And Starter For Submersible Motor At Munsiff Court, Adoor-Repairs Of Submersible Motor-General Electrical Work

BOQ

Work Name:GENERAL-Replacement of damaged cable and starter for submersible motor at Munsiff court, Adoor-Repairs of Submersible motor-General Electrical Work
Sl. No. Item Description
1Repaires
2OD73682/2022-2023:Supply, conveyance, installation, testing and commissioning of 1x20W box type LED light fittings with all accessories and lamp in place of defective fittings and giving connections as required
390.3.20.3:Supply & installation of light fittings on TW round block <br> Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thicknesscomplete with all accessories andlamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
4OD68206/2022-2023:Supply and providing 1200mm 2000lm or better LED tube in place of defective one including modifying connections etc as required
51.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
690.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
790.3.18.1:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps
890.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
9OD73607/2022-2023:Supply and instalation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required. 305mm sweep 1400rpm heavy duty exheaust fan
101.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
111.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
121.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
131.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
141.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
151.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
161.24.8:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
171.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
181.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
191.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
201.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
211.27.6:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
221.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
231.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
24OD67959/2022-2023:Charges for dismantling switch boards and other fittings and conveying to store
252.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door
262.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
272.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2890.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
2990.10.1.6:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface
30OD68224/2022-2023:Supply conveyance, installation, testing and commissioning of Electro mechanic Control Panel board of borewell submersible pump (1.5HP ) with Direct Start, single phase 220V AC Power Supply, having Volt meter, Ammeter, Indicating lamp(Motor ON), Run and Start capacitorm, Overload protection, Contactor with thermal overload relay resettable panelfittings directly on wall giving connections with the extended original wiring, making good the damages, colour washing etc. as required (Lubi or equivalent)
3190.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top
3290.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
3390.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size

AI Tender Summary

OUR REF NO 33190959
AUTHORITY Government Departments
TENDER VALUE 56452
LAST DATE 29-07-2022
Authority
Authority Name Public Works Department
Work Description General-Replacement Of Damaged Cable And Starter For Submersible Motor At Munsiff Court, Adoor-Repairs Of Submersible Motor-General Electrical Work General-Replacement Of Damaged Cable And Starter For Submersible Motor At Munsiff Court, Adoor-Repairs Of Submersible Motor-General Electrical Work
Basic Detail
Tender No PWD/BLDG/5366/2022-2023
Bidding Type Tender
Location
City adoor
State Kerala
Key Dates
Publish Date 21 Jul 2022
Submission Date 29 Jul 2022
Open Date 01 Aug 2022
Finance
Tender Value 56452
Tender Fee 555
EMD 1411
Exemption Not Available
Document List
7845705f-ae1d-49d9-b0bf-e6dd58f9de0b.html
BOQ_717209.xls
Make_of_materials.pdf
SBD3.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 21, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 29, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 01, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

7845705f-ae1d-49d9-b0bf-e6dd58f9de0b.html

xls

BOQ_717209.xls

pdf

Make_of_materials.pdf

pdf

SBD3.pdf

pdf

Tendernotice_1.pdf

Disclaimer