| Sl. No. | Item Description |
| 1 | REPAIR / MAINTENANCES OF DG SETS, AMF PANELS, SERVO STABILIZERS AND CONNECTED WORKS AT NORTH SIDE RUNWAY UNDER GE (NW) VASCO |
| 2 | Service Charges for Carrying out \"C\" Check maintenance for DG sets from authorised rep or trained service engineer from the OEM of DG set of 320 KVA capacityinjector & valve tappet setting, checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacement of filters & oil, checking inlet & Exhaust manifold cap, screws, checking of fan hub & water pump, removing the existing unserviceable engine oil, clean the oil sump and refilling with required quantity of new oil & coolant top up, charging of battery, filling of distilled water, cleaning of radiator fins by using blower /inside tank with solution (caustic soda with water) to the entire satisfaction of Engineer-in-Charge, trial & testing etc.(Note :- (a) New spares required for \"C\" check will be measured and paid separately as supply only. |
| 3 | Supply only Kit fuel filter |
| 4 | Supply only Element for Lubrication oil filter. |
| 5 | Supply only Kit Element of super bypass filter. |
| 6 | Supply only Kit Conversion |
| 7 | supply only fuel Feed pump |
| 8 | Supply only Kit Fuel & coolent hoses |
| 9 | Supply only Belt set |
| 10 | Supply only Air Cleaner element outer and inner complete. |
| 11 | S&F in repairs Low lub oil pressure switch with adaptor |
| 12 | All as per item No 1.00 above butDG set of 200/ 250 KVA capacity Engine. |
| 13 | Supply only Lubrication oil filter |
| 14 | Supply only Air Cleaner element outer and inner complete. |
| 15 | Supply only Kit Conversion |
| 16 | Supply only Fuel Filter |
| 17 | Supply only Kit Fuel & coolent hoses |
| 18 | Supply only Belt set |
| 19 | Supply only bypass filter |
| 20 | supply only fuel Feed pump |
| 21 | All as per item No 1.00above but DG set of 100/125 KVA capacity Engine. |
| 22 | Supply only Filter Fuel element |
| 23 | Supply only Cartridge, Lub oil filter |
| 24 | Supply only Air Cleaner element outer and inner complete. |
| 25 | Supply only Kit Conversion |
| 26 | Supply only Kit Fuel & coolent hoses |
| 27 | Supply only Belt set |
| 28 | Supply only fuel Feed pump |
| 29 | All as per item No 1.00above but DG set of 30/35KVA capacity Engine. |
| 30 | Supply only Lubrication oil filter element |
| 31 | Supply only Fuel Filter element |
| 32 | Supply only Kit Conversion |
| 33 | Supply only Kit Fuel & coolent hoses |
| 34 | Supply only Belt set |
| 35 | Supply only Air Cleaner element outer and inner complete. |
| 36 | supply only fuel Feed pump |
| 37 | All as per item No 1.00 above butDG set of 20 KVA capacity Engine. |
| 38 | Supply only Lubrication oil filter element |
| 39 | Supply only Fuel Filter element |
| 40 | Supply only Kit Conversion |
| 41 | Supply only Air Cleaner element outer and inner complete. |
| 42 | Supply only Kit Fuel & coolent hoses |
| 43 | Supply only Belt set |
| 44 | supply only fuel Feed pump |
| 45 | All as per item No 1.00 above but DG set of 15 KVA capacity Engine. |
| 46 | Supply only Lubrication oil filter element |
| 47 | Supply only Fuel Filter element |
| 48 | Supply only Air Cleaner element outer and inner complete. |
| 49 | Supply only Kit Conversion |
| 50 | Supply only Kit Fuel & coolent hoses |
| 51 | Supply only Belt set |
| 52 | supply only fuel Feed pump |
| 53 | All as per item No 1.00 above but DG set of 62.5to 65 KVA capacity Engine. |
| 54 | Supply only Lubrication oil filter element |
| 55 | Supply only Fuel Filter element |
| 56 | Supply only Air Cleaner element outer and inner complete. |
| 57 | Supply only Kit Conversion |
| 58 | Supply only Kit Fuel & coolent hoses |
| 59 | Supply only Belt set |
| 60 | supply only fuel Feed pump |
| 61 | All as per item No 1.00 above but DG set of 625 KVA capacity Engine. |
| 62 | S & F in repairs Kit, fuel filter |
| 63 | S & F in repairs Element for Lubrication oil filter. |
| 64 | S & F in repairs Kit, Element of super bypass filter. |
| 65 | S & F in repairs Air filter Outer element. |
| 66 | S & F in repairs Air Filter inner element. |
| 67 | Supply only Kit Fuel & coolent hoses |
| 68 | Supply only Belt set |
| 69 | Supply only Kit Conversion |
| 70 | S & F in repairs fuel feed pump assly |
| 71 | All as per item No 1.00 above but DG set of 500 KVA capacity Engine. |
| 72 | S & F in repairs Kit, fuel filter |
| 73 | S & F in repairs Element for Lubrication oil filter. |
| 74 | S & F in repairs Kit, Element of super bypass filter. |
| 75 | S & F in repairs Air filter Outer element. |
| 76 | S & F in repairs Air Filter inner element. |
| 77 | Supply only Kit Conversion |
| 78 | Supply only Kit Fuel & coolent hoses |
| 79 | Supply only Belt set |
| 80 | S&F in repairs fuel feed pump |
| 81 | All as per item No 1.00 above but DG set of 400 KVA capacity Engine. |
| 82 | S & F in repairs Lubrication oil filter, Cartridge. |
| 83 | S & F in repairs Fuel Filter element |
| 84 | Supply only Kit Conversion |
| 85 | S & F in repairs Kit, Element of super bypass filter. |
| 86 | S & F in repairs Air filter Outer and inner element complete. |
| 87 | Supply only Kit Fuel & coolent hoses |
| 88 | Supply only Belt set |
| 89 | S&F in repairs fuel feed pumpNote :- (1) The \"C\" Check Maint spares, engine oil, Coolant, caustic soda solution (restore plus) will be measured and paid separately under relevent item of this schedule. (2) Any other check as per menufacturer\"s instructions / Engr In charge directeion shall be carried out by the contractor and the same may be included in the quoted rate and directed by Engineer-in-Charge. |
| 90 | S & F in repairs Radiator assy with tank of complete set made up of copper/ aluminium fins and tube suitable for 15KVA to 320 KVA DG set of any make all as directed. |
| 91 | Service Charges for Carrying out the \"B\" Check maint from authorised rep or service engineer from the manufacturer of DG set of 320 KVA capacity Enginechecking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacement of filters, checking inlet & Exhaust manifold caps crews, checking of fan hub & water pump, toping up level the existing engine oil, coolant top up and in replacement, supplying & fixingof following spares :-(a) Kit, fuel filter and ring - 2 Kit(b) Element for Lubrication oil filter - 2 Nos.Note :- \"B\" check shall be carried out on running of 500 hrs or three months whichever is earlier.(c) Kit, Element of super bypass filter - 01 Kit |
| 92 | All as per item No. 1.90 above here above but DG Set Capacity 200/250 KVA. |
| 93 | All as per item No. 1.90 above here above but DG Set Capacity 100/125 KVA. |
| 94 | All as per item No. 1.90 above here above but DG Set Capacity 62.5 to 65 KVA. |
| 95 | All as per item No. 1.90 above here above but DG Set Capacity 30/35 KVA. |
| 96 | All as per item No. 1.90above here above but DG Set Capacity 20 KVA. |
| 97 | All as per item No. 1.90 above here above but DG Set Capacity 15 KVA. |
| 98 | All as per item No. 1.90 above above but DG Set Capacity 625 KVA. |
| 99 | All as per item No. 1.90 above above but DG Set Capacity 500 KVA. |
| 100 | All as per item No. 1.90 above above but DG Set Capacity 400 KVA. |
| 101 | Supply & filling Coolant concentrate Superkool xtra as required in the DG oil sump all as directed. |
| 102 | Supply & filling Engine Oil Premium15 W 40 grade API CI 4 PLUS as required in the DG oil sump all as directed. |
| 103 | Supply & chelating cleaner Restore Plus solution Part No. AX1001098Make : Cummins for engines cooling system all as directed. |
| 104 | Dismantling the defective alternator of any capacity from the existing foundation and from Engine after removing all electrical connections, transporting to approved / authorised / directed workshop, opening and taking out burnt winding, cleaning the stator assy rewinding with super enameled copper wire as per existing gauge as per original manufacturer and applying insulating varnishing of ‘F’ class, baking in oven re-assembling the alternator, transporting back tosite re-installing the same position, carrying out alignment of complete DG set connecting up all electrical connections testing and commissioning complete.Note: - (a) Rate quoted shall be deemed to be inclusive of making good the disturbed surfaces.(b) The DG set shall be tested on load as per rated capacity for the satisfaction of Engineer- in- Charge to achieve designed parameters. |
| 105 | Dismantling the defective alternator of any capacity from the existing foundation and from Engine after removing all electrical connections, transporting to approved / authorised / directed workshop, opening and taking out burnt winding, cleaning the main Rotor assy rewinding with super enameled copper wire as per existing gauge as per original manufacturer and applying insulating varnishing of ‘F’ class, baking in oven re-assembling the alternator, transporting back tosite re-installing the same position, carrying out alignment of complete DG set connecting up all electrical connections testing and commissioning complete.Note: - (a) Rate quoted shall be deemed to be inclusive of making good the disturbed surfaces.(b) The DG set shall be tested on load as per rated capacity for the satisfaction of Engineer-in-Charge to achieve designed parameters. |
| 106 | S & F in repair door hinges for canopy of any capacityofDGset doorincluding nut, bolt, drilling of hole, welding as per directed. |
| 107 | Supply and fixing in repair battery terminals brasssuitable for 95 AH to 180 AH battery . |
| 108 | Dismantling & chemical cleaning of radiator assy from the DG set of 125 to 320 KVAcapacitycarefully for necessary repair, soldering the cooling tube if found weak /leakage,cleaning properly, replacement of nuts, bolts, rubber mounting bushes etcand refixing at the same site including testing on completion. |
| 109 | All as per Item No. 2.07 above, but for 15 KVA to 100 KVA DG set |
| 110 | S & F battery charging unit panel mounted automatic operated electronically24 Volts DC out put and 230 volts incoming AC, as per the existing make and size to accommodate in the space provided in the AMF panel board. |
| 111 | S & F battery charging unit panel mounted automatic operated electronically12 Volts DC out put and 230 volts incoming AC, as per the existing make and size to accommodate in the space provided in the AMF panel board. |
| 112 | S & F in repairs connecting and commissioninglead acid battery 12 volts 180 AH. |
| 113 | S & F in repiarsconnecting and commissioning lead acid battery 12 volts 130 AH. |
| 114 | Dismantling the unserviceable Dynamo / Alternators 12/24 volts and rewindingwith ‘F’ class copper wire of 22 /existing gauge incl dismantling the old coil, cleaning thoroughly and winding with super enamelled copper cord of existing size and gauge, varnishing, drying etc and re fixing with dynamo/ alternator properly including testing on completion. |
| 115 | Dismantling the defective Dynamo /Alternators 12/24 volts and necessary repair with replacement of defective spares such as, carbon brushes, carbon spring, bearing, bushes, defective wiring, and soldering after re-fixing at site. |
| 116 | Dismantling the defective self starter assy of 12/24 volts and necessary repair with replacement of defective spares such as, carbon brushes, carbon spring, bearing, bushes, defective wiring and soldering after repair, re-assembling and refixing at site complete as directed including testing on completion. |
| 117 | M&L for providing new AVR unit suitable for 62.5 KVA to 200 KVA DG Set size in repairs ie taking down of old AVR unit, complete all as specified and as directed by Engineer-in-Charge. |
| 118 | All as per Item No 2.16 above, but for 320 to 625 KVADG set |
| 119 | All as per Item No 2.16 above, but for 15to 35 KVA DG set |
| 120 | Dismantling the old and unserviceable DG Set oil pressure pipe of existing sizeand replacing the same with ofexisting size and equal length of15 KVA to 320 KVADG Set includingboth side hose clamp, etc as directed by the Engineer- in- Charge . |
| 121 | Dismantling the defective exciter of DG set of any capacity from the existing foundation and engine after removing all electrical connections, transporting to workshop rewinding the burn out coil complete with super enamelled copper wire rewinding, applyinginsulating varnish of \"F\" class baking in oven reassembling the alternator, transporting back to site, re-installing the same carrying out alignment of complete DG Set connecting up all electrical connections, testing & commissioning complete. |
| 122 | Supply and fixing in repair type digital volt meter square type 96x96 mm up to 3 Phase AC 50 HZ, 500 volts of and connecting complete. |
| 123 | Supply and fixing copper cable multi stranded suitable for 12/24 volts battery replacing the same with ofexisting size and equal length complete fixing with brass clamp at both ends including taking down of old one from the existing battery. |
| 124 | supply and fixing of lamp indicator assy LED lamp type 230 volts AC . |
| 125 | S &F in repair asbestos rope 12 mm dia of superior quality for wrapping with the exhaust pipe of the DG set complete as directed. |
| 126 | Scraping the old paint from the DG set of 320 KVA capacity, applying one coat of synthetic enamel paint of approved make, writing of SM/MES No at easily visible manner complete as directed. |
| 127 | All as per item No. 2.25 above but DG Set 100 KVA to 250KVA DG Set. |
| 128 | All as per item No. 2.25 above but DG Set 15 KVA to 63KVA DG Set. |
| 129 | S & F in repairs Turbo kit for 320KVA DG Set for Cummins / Kirloskar / Greaves DG Set |
| 130 | S & F in repairs Turbo kit for 62.5 to 250 KVA DG Set for Cummins / Kirloskar / Greaves DG Set |
| 131 | S & F in repairs self starter 12V/24V with sononoid switch assy complete set as per existingmake of DG Set 320KVA all as directed. |
| 132 | S & F in repairs self starter 12V/24V with solenoid switch assy complete set as per existing make of DG Set for 100 to 250 KVA all as directed. |
| 133 | S & F in repairs Engine solenoid switch 12 Volt complete set as per existing size and make of DG Set. |
| 134 | S & F in repairs Engine solenoid switch 24 Volt complete set as per existing size and make of DG Set. |
| 135 | S & F in repairs magnetic speed censor assy suitable for Kirloskar make DG sets all as directed. Make : Kirloskar |
| 136 | S & F in repairs Electronic DG controller control unit suitable for 100 to 250 KVA Capacity DG sets incl neccessary connections and testing complete all as directed. |
| 137 | S & F in repairs ElectronicDG controller control unit suitable for 320KVA Capacity DG sets incl neccessary connections and testing complete all as directed. |
| 138 | S & F in repairs ElectronicDG controller control unit suitable for 15 to 63 KVA Capacity Kirloskar make DG sets all as directed. |
| 139 | Dismantling and taking out the defected Electromagnetic speed Governor unit with fuel injector pump assy from the DG set, transport to authorised work shop, cleaning the Fuel injector, Nozzle, calibration in test bench re-assembling into the DG set with necessary new gaskets/ nut, bolt and washer and testing complete all as directed. Note : The cost of spares like new injector/nozzle/gasket/seal/nut, bolt and washers are deemed to be included in the quoted rates. |
| 140 | S & F in repairs Complete Wring harness system incl necessary elect connections for 15 to 125 KVA Capacity Kirloskar Make DG set complete all as directed. |
| 141 | All as per item No. 2.39here in before but of 160 to 320 KVA capacity |
| 142 | S & F in repairs self starter push button / or with Key arrangement for DG starting suitable for Kirloskar / Cummins DG sets all as directed. |
| 143 | S & F in repairs governer controller unit suitable for 320 KVA Capacity Kirloskar make DG sets incl neccessary connections and testing complete all as directed. |
| 144 | S & F of distilled water in the DG battery all as directed. |
| 145 | Supply and fix in repair changeover swithcs on load changeover switches 4 pole 400 Amps in sheet steel enclosure with inclosure as per the directions of Engineer-in-charge |
| 146 | M & L for openingthe cylinder head of the engine and oil sump carefully for replacement of head gasketincluding sump gasketcomplete refixing the headand sump to arrest oil leakage with engine complete with proper alignment and testing the enginefor 1 hrson load to achiveve designed parameters all as directed by Engineer-in-Charge of capacity 15 KVA to 125 KVA. |
| 147 | M & L for openingthe cylinder head of the engine and oil sump carefully for replacement of head gasketincluding sump gasketcomplete refixing the headand sump to arrest oil leakage with engine complete with proper alignment and testing the enginefor 1 hrson load to achiveve designed parameters all as directed by Engineer-in-Charge of capacity160 KVA to 320 KVA. |
| 148 | Charges for attending break down of DG set of320 to 600 KVA capacity by only auth OEM rep /OEM trained engineer/ team for fault finding incl attending repairsas and when required such as No start condition of DG and repairing, starting the DG set till smooth running and setting up the alighnment / required paramenters of all major parts such as fan belt, AVR, RPM, sencors, actuators, Engine safety units, bty chargers, fuel / oli levels, speed governer,Micro processor based control panel, Injector pumps etc as required in ground / as ordered by EIC all as directed. |
| 149 | All as per item No 2.47 here in before but of DG set capacity 15 to 250 KVA |
| 150 | S&F VM Relay |
| 151 | Preventive maintenance of AMF Panel for its smooth functioning and working performance, checking all electrical connection replacing the worn out electrical parts complete all as directed by Engineer-in-Charge. (Note:- Spare parts will be measured and paid seprately under the relevant items. |
| 152 | S&F of Relay card for DG set controller of any capacity |
| 153 | S&F of Conatctor for 500A DG set |
| 154 | S&F of Conatctor for 400A DG set |
| 155 | S&F of Conatctor for 300A DG set |
| 156 | S&F Of Contactor for 250A DG set |
| 157 | S&F of Lockable trip push buttonof any capacity |
| 158 | S&F of Locking of ACB in isolated position |
| 159 | S&F of Locking of ACB in anyposition |
| 160 | S&F of Shunt release (SR)FOR 24 V DC to 220 V DC for ACB |
| 161 | S&F of Shunt release (SR)FOR 110V AC to 4150 V AC for ACB |
| 162 | S&F of Under voltage releaseType MV : 24V DC / 240 V AC / 415 V AC for ACB |
| 163 | Excavation in post holes in soft and loose soil n. exc 0.5 cum each and removing surplus soil to a diastance n exc 50m and making good surfaces etc complete all as specified and directed. |
| 164 | Cement concrete in foundation filling and mass concrete Type D-2 (1:4:8) 40mm graded agrregates etc complete all as specified and directed. |
| 165 | S& F Pre painted galvatume aluminium Zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding fixed with self taping screws as specified. |
| 166 | M&L in replacement of steel work in tubularsection, rolled section as columns, posts including welding to plates, angles forming bases for columns and brackets for sheds etc complete all as specified. |
| 167 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer including preparation of newly or previously untreated surfaces on steel surfaces. |
| 168 | Dismentalling of 320 kVAalternator from DG set, removing of Flywheel & replacement of flywheel ring gear with new one & refixing of all concern accessories properly as directed by engr-in-charge. (Ring gear will be measured extra as only supply item) |
| 169 | Supply of flywheel ring gear complete. |
| 170 | Dismantling and removing the carroded DG Set outer enclouser complete and then supply and fix new enclouser for 200/250 KVA DG Set conforming to CPCB Norms II , noise should not more than 75 dba @ 1 mtr including diesel tank at bottom and aligning of alternator and diesel engine and all other connected works.Note :- The outer enclouser /canopy shall be fabricated as per CPCB norms -II from manufacturers / their authorised OEM |
| 171 | Supply and fix in repair Thermostat for any make and any capacity complete all as specified and directed by Engineer-in-Charge. |
| 172 | Supply and fix in repair watrer pump assy of capacity 63 KVA to 250 KVA of any make complete all as specified and directed by Engineer-in-Charge. |
| 173 | Supply and fix in repair watrer pump assy of capacity 320 KVA to 625 KVA of any make complete all as specified and directed by Engineer-in-Charge. |
| 174 | REPAIR / MAINTENANCE OF EXTERNAL ELECTRIC LT OH LINES / UG CABLES / LT POLES, STREET LIGHT, PERIMETER LIGHT, HIGH MAST LIGHT AND CONNECTED WORKS AT NTS, CAVELLOLISM, NDB AND HANSA VIHAR AT INS HANSA |
| 175 | Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in hard/dense soil getting out and levelling of bottom surface to required level for laying UG cable / errection of poles all as specified. |
| 176 | Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in soft/ disintegrated rock getting out and levelling of bottom surface to required level all as specified. |
| 177 | Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish all as all as directed by Engineer-in-Charge. |
| 178 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick all as specified. |
| 179 | Removing excavated material of soils from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point.all as specified. |
| 180 | Supplying & Laying in trenches Clear Sand/m- Sand for cushioningunder ground cable 8 cm below and 15 cm above complete in level all as specified.Note: Punned thickness only will be measured and paid. |
| 181 | Supplying & Layingprecast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm in trenches for protect to under ground cable complete all as specified. |
| 182 | Taking down old unserviceable LT UG cable from any description (trenches, walls, Poles, ceilings., etc) from various locations, Supply and laying under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 10 Sq mm, 4 core, with aluminium conductor, ISI marked as per IS : 7098 (Part-1) along with suitable size aluminium cable lugs, gland if required and jointed in any description complete all as specified. |
| 183 | All as per item No.3.08 here in before but of size 4 core 16 sqmm |
| 184 | All as per item No.3.08 here in before but of size 4 core 25 sqmm |
| 185 | All as per item No.3.08 here in before but of size 3 1/2 core 35 sqmm |
| 186 | All as per item No.3.08 here in before but of size 3 1/2 core 50 sqmm |
| 187 | All as per item No.3.08 here in before but of size 3 1/2 core 95 sqmm |
| 188 | All as per item No.3.08 here in before but of size 3 1/2 core 240 sqmm |
| 189 | Note for item No 3.08 to 3.14 :- 1. Excavation, Concrete cable protection cover, pipe, PCC work for road crossing / hard standing and Sand for cushioning will be measured and paid separately.2. Cost of glands,aluminium cable lugs (eye lid / barrel / bottle neck type/ring type or any shape), new nut, bolt and washers of required size / description are deemed to include in this rate. |
| 190 | M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work / using any description all as directed. |
| 191 | M & L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate including use and waste of form work / using as coping / any description all as dirceted. |
| 192 | M & L for preparation of old painted surface, cleaning the surface of the RCC pole (LT) above theground level to top of the pole incl coping area (if provides) with one coat of ACC exterior Emulsion paint as per exisitng colour all around the pole all as directed. |
| 193 | Supply and fix or laying in trenches / on wall / poles / structures as in repairs GItubing light grade for road crossing / for cable protection / fixing of pigmi lights etc,of the following sizes including necessary provision for cable entry if reqd in pigmi lights pole, fixing screws complete as required all as directed. |
| 194 | (a)100 mm dia |
| 195 | (b)80 mm dia |
| 196 | (c)50 mm dia |
| 197 | (d)40 mm dia |
| 198 | M & L for Earthing complete with GI earth plate, electrode,600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 32x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 5 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber all as specified and directed by Engr-in-Charge including demolish existing earth pit taking out old materials. |
| 199 | M & L for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamberin cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed . |
| 200 | M & L forEarthing complete with copperearth plate, electrode,600 x 600 x 3.15 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to Copper strip size 20 x 3 mm thick dia by means of nuts, bolts, & washers of GI as shown in electrical plate No. 5 of SSR Part-I Connected to earthing test point all as specified and including necessary earth pit PCC 1:3:6 chanber be 50 mm thick PCC 1:2:4 chamber cover with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover , watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 32 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber all as specified and directed by Engr - in - Charge. |
| 201 | Supply and fix in repairs cable junction boxes IP 66 protected “halogen free and weather proof” suitable for out door type ( with metric knockouts for cable entry) of size 250 x 200 x 100 mm mm incl necessary suitable size new aluminium bus bar 04 Nos mounted on saddles suitable for 3 phase 4 wire system of suitable length and thickness, provn of new aluminium cable lugs for incoming & out going LT cable connections with junction box fixing clamps made up of GI flat 25 x 3 mm, nut and bolt on poles complete all as directed . |
| 202 | Supply and fix in repairs cable junction boxes IP 66 protected “halogen free and weather proof” suitable for out door type(with metric knockouts for cable entry) of size 300 x 200 x 100 mm mm incl necessary suitable size new aluminium bus bar 04 Nos mounted on saddles suitable for 3 phase 4 wire system of suitable length and thickness, provn of new aluminium cable lugs for incoming & out going LT cable connections with junction box fixing clamps made up of GI flat 25 x 3 mm, nut and bolt on poles complete all as directed . |
| 203 | Taking out the existing unserviceable MCCB from any description , Supply and fix MCCB 4 pole 415 volts with adjutable type 100 to160 Amps with breaking capacity 35 KA complete including necessary connection with suitable size aluminum / copper cable lugs all as specified and as directed. |
| 204 | Taking out the existing unserviceable MCCB from any description , Supply and fix MCCB 4 pole 415 volts with adjutable type 200 to 250 Amps with breaking capacity 35 KA complete including necessary connection with suitable size aluminum / copper cable lugs all as specified and as directed. |
| 205 | S & F in repairs HT / LT MS cable route indicator with two Nos of nut, bolt and washers and provision of PCC 1:4:8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base buried under the groundincl necessary earth work complete all as directed. |
| 206 | Supply and fix Street light bracket made out of GI tubing 32/40 mm dia light grade bend to shape suitable for above mentioned Bldg security light/street light/Pigmi light fittings with necessary GI clamps 40mm x 6 mm - 02 Nos including nut, bolt, washers etc all as specified. |
| 207 | Supply and fix in repairs LED post with die cast aluminium body and with white powder coated aluminium reflector and IP-65 protection of 40 watts capacity all as directed. |
| 208 | S & F in repairs Energy efficient LED street LightLuminaire 60/72 watts capacity comprises a die-cast aluminium housing all as directedincluding connections with 2 run of 2.5 Sq mm aluminium unsheathed wire multistranded from LT over head line/ UG Cableto the connector of fitting, connection wires not to be more than 2.5 metre in length duly run through GI bracket complete all as directed . |
| 209 | All as per item No 3.34 here in before but of capacity90 watts . |
| 210 | All as per item No 3.34 here in before but of capacity120 watts . |
| 211 | All as per item No 3.34 here in before but of capacity150 watts. |
| 212 | Supply and fix in repairs Galvanised Iron cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete incl taking down / dismantling the old items complete all as directed. |
| 213 | S & F in repairs Pin type porcelain vitreous,brown of white insulator to suit 1100 Volt working pressure of size 100 mm height, 65mm dia, including one galvanised mild steel spindle, two galvanished iron washer and one GI nut complete all as directed. |
| 214 | S & F in repairs Shackle typePorcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, of height 100 mm and dia 115 mm having working pressure 1100 volts grade complete all as directed. |
| 215 | Dismantling of existing old unserviceable ACSR of any size from any descritpion all as specified and directed by engr-in-charge. |
| 216 | Taking down the GI / PVC cable protection pipe along with UG cable from pole / wall by disconnecting all incoimg and outgoing connections from the unserviceable street / security lightjunction boxes and breaking thepole coping, opening the cable loop kept under the pipe / any description by excavation of earth work, cut the damaged portion of UG cable of any size and making new termination arrangementetc,. cut the GI / PVC pipe of required length, re-filling the exavated soils complete all as directed.(Note:- PCC rate are measured and paid separatly) |
| 217 | Taking down of existing UNSV flood light fitting of any type, supply and fixLED Flood light fittings 180 Watts incl fixing arrangement and necessary connections complete all as directed. |
| 218 | Taking down of existing UNSV flood light fitting of any type, supply and fixLED Flood light fittings 200 Watts incl fixing arrangement and necessary connections complete all as directed. |
| 219 | S & F in repairs LED Aviation light comprising of aluminium housing with polycarbonate enclosure, 302 Nos. LED are provided with necessary fixing arrangements & electrical connections all as directed. |
| 220 | M & L for LT heat shrinkable cable Jointing kit suitable for 3.5/4.0 core 06 to 16 Sqmm aluminium cable all as directed. |
| 221 | M & L for LT heat shrinkable cable Jointing kit suitable for 3.5/4.0 core 25 to 50 Sqmm aluminium cable all as directed. |
| 222 | M & L for LT heat shrinkable cable Jointing kit suitable for 3.5 core 70 to 95 Sqmm aluminium cable all as directed. |
| 223 | M & L for LT heat shrinkable cable Jointing kit suitable for 3.5 core 120 to 185 Sqmm aluminium cable all as directed. |
| 224 | M & L for LT heat shrinkable cable Jointing kit suitable for 3.5 core 240 to 300 Sqmm aluminium cable all as directed. |
| 225 | M & L for removing vegitation, grass, scrubs and bushes or any small tree branches growing in Sub station yard along with fancing, around the pole, under the HT/LT transmission lines, yards or any description by mannually / mechanically and keep the sub station yard neat and clean complete all as specified and as directed. Note :- Unit rate quoted deemed to include to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid. |
| 226 | M & L for Cutting and trimming of tree branches of girth upto 150 mm dia and 3 mtr all around of any size obstructing lumination of street light/ perimeter lights and touching LT / HT Over head line incl removing trimmed tree branches all as directed.Note : Each cut will be measured and paid |
| 227 | M & L for graded coarse aggregate (broken stone or boulders) of size 40 mm in substation yard for layingall as directed and specified. |
| 228 | S & F in repairs LT PVC line spacer suitable for existing 3 phase 4 wire OHT system all as directed |
| 229 | S & F in repairs LT junction box suitable for 1100 Volt gradeoutdoor type, single door, pedestal mounted, overall size not less than 450 x 450 x 450 mm,having aluminium bus bar of400 A capacity - 04 Nos with necessary hole for connection of LT cables mounted on suitable strength epoxy insulator 1100 KV grade -12 Nos in width wise, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheetsuitable for 3 Phase 4 wite system, duly insulated with heat shrinkable type coloured sleeve, supported on suitable size \"C\" Channel in the vertical position - 03 Nos,LT danger notice board fixed on dooron both side, with independent plates at bottom for each out going and in coming cables in cable alley and painted with powder coatingin Siemens grey colour andincl Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legsand made out of ISA 4040, 40 x 40 x 6 mm thick angle iron duly painted - 01 No.all as approved andas directed. |
| 230 | Supply only ofPVC electrical LT insulation tape 18 mm width in 6 mtr roll all as directed. |
| 231 | Supply and fix ofalluminium cable luggs of following size complete all as specified and directed by Engineer-in-Charge |
| 232 | (a) 10-16 sqmm dia |
| 233 | (b)25-35 sqmm dia |
| 234 | (c ) 50-70 sqmm dia |
| 235 | (d)95-120 sqmm dia |
| 236 | (e) 150-195 sqmm dia |
| 237 | (f)240-300 sqmm dia |
| 238 | Supply and fix ofcable gland of following size complete all as specified and directed by Engineer-in-Charge |
| 239 | (a)10-25 sqmm dia |
| 240 | (b) 25-70 sqmm dia |
| 241 | (c )95- 185sqmm dia |
| 242 | (d) 240-300 sqmm dia |
| 243 | S & F perforated cable tray made out of GI Sheet of 14 SWG thickness and 40 to 50 mm depth hot dipped in various width sizes including accessories like couplar plate, nut bolts, washers clamps, wall bracket up/down elbows, bends tees equal distances on wall/floor/through wall crossing and making good the surface, completeall asspecified and as directed. |
| 244 | S&F in repair reflective informatory sign boards with single side writing as per IRC 67 made of high intensity grade sheeting, fixed over aluminium sheet3 mm thick, supported on angle iron / GI pipes fixed in PCC including welding and painting with two coats of synthetic enamel paint over a coat of primer complete all as directed. (MS Angle/Square tube iron work /GI pipe / GI Angle PCC will be measured and paid seperately under relevent item of this schedule) |
| 245 | M & L for Steel work in tubular trusses including special shaped washer etc. completebutt welded tubes conforming to I. S.1161- 1979 grade St.-240 |
| 246 | Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m |
| 247 | Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m |
| 248 | S & F in repair Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15 cm size all as directed. |
| 249 | Dismantling stay assembly complete and all as specified and directed by Engr-in-charge. |
| 250 | M & L as in repairs for stay assembly complete with all sections such as stay plate, stay clamps, Stay brackets with 20 mm dia stay rod complete all as shown in electrical plate No. 1 of SSR Part I complete. (Note :Loop insulator, excavation and concrete work will be measured and paid separately) |
| 251 | Dismantling concrete poles/ struts, any size , removing the old UNSV pole from site all as specified and directed by Engr-in-charge |
| 252 | Supply & transporting and erecting in replacement octagonal hot dipped galvanised mild steel pole with grey powder finish 7 meter long complete with top dia of size 70 mm and bottom dia of sie 130 mm including base plate of size 200 x 200 x 12 mm, foundation nuts bolts including RCC foundation of suitable size to withstand the said pole and GI bracket for mounting on top of the pole for fixing of 01 Nos of street light complete all as specified and directed by Engineer-in-Charge for street lights |
| 253 | S & F in repairs PVC Copper cable 3 core 2.5 sqmm, 1100 volts all as specified and directed by Engineer-in-Charge |
| 254 | Supply and fixing LED Solar street light fitting 36/40 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete. (Excavation & earth work shall be measured separately |
| 255 | S& F in repairs rolled Mild steel plates of FE 410 -10 (Gde-E 250)(Plain) of (Cable duct cover) A grade as required size including cover welded aroud with MS flat iron of required size with locking arrangements including painting with two coats of synthetic enamel paint over a coat red oxide primer. |
| 256 | S & F in repairs CO2 type fire extinguisher with trolley with delivery hose, mounting clamps, and standard accessories of capacity 6 kg capacity all as directed. |
| 257 | M & Lpainting of HT / LT Panel of any sizeby preparation of old surface and applying one coat of red oxide primer and two coat of synthetic enamelled paint of standard colour code as existing surface all as specified and directed by Engineer-in-Charge |
| 258 | Supply and fix in repair changeover swithcs on load changeover switches 4 pole 200/250 Amps in sheet steel enclosure with inclosure, including necessary spreaders/cable lugs/ gland / nut, bolt and washers if required complete all as specified and directed by Engineer-in-Charge. |
| 259 | Supply onlyLED driver with transformer suitable for 25 to 60 watts LEDstreet/ Flood/ high bay light fitting of complete all as specified and directed by Engineer-in-Charge. |
| 260 | All as per item No. 3.85 here in beforebut of capacity 70 to 90 watts LED fittings complete all as specified and directed by Engr-in-charge. |
| 261 | All as per item No. 3.85 here in beforebut of capacity 120 to 150 watts LED fittings complete all as specified and directed by Engineer-in-Charge. |
| 262 | Material and labour for fault finding of LT cables of anysizeany length with fault detective machine by thumbing method and suitablevoltage and all as permanufactures instructions including providing straight through joint and additional cable ofsame existing size suitable to site requirement complete all as specified and directed by Engineer-in-Charge. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail