Repair / Replacement Of Pump Motors, Starter, Control Panels, Apfc Panels And Connected Items Of Work At Rajouri Under Ge 862 Ews, Rajouri-Jammu And Kashmir

Military Engineer Services-MES has published Repair / Replacement Of Pump Motors, Starter, Control Panels, Apfc Panels And Connected Items Of Work At Rajouri Under Ge 862 Ews. Submission Date for this Tender is 23-08-2022. Starter Tenders in Rajouri Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

33178752
Corrigendum : Repair / Replacement Of Pump Motors, Starter, Control Panels, Apfc Panels And Connected Items Of Work At Rajouri Under Ge 862 Ews
Open Tender
Indian
Jammu And Kashmir
Rajouri
23-08-2022

Tender Details

Repair / Replacement Of Pump Motors, Starter, Control Panels, Apfc Panels And Connected Items Of Work At Rajouri Under Ge 862 Ews

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Aug-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-08-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 84000.0 /-
Tender Value
INR 42 Lakhs /-

BOQ Items

Name of Work: Repair/replacement of pump motors, Starter, control panels, APFC panelsand connected items of works at Rajouri under GE 862 EWS
Sl. No. Item Description
1Disconnecting the 150 HP centrifugal pump (Make : Kirloskar/Jyoti/BE/Crompton greaves/Bhart Bijlee/WPIL and others) from the motor after disconnection of mechanical tyre coupling, suction/discharge pipe line and unbolting from foundation base plate,loading/unloading the pump to vehicle and transportation of the pump from Rajouri E/M installation to workshop as directed by Engineer-in-Chargefor repair/replacement/maintenance and including dismantling & re-assembling the pump impeller with housing, stainless steel shaft,bearing for smooth running, replacement of packing gaskets, shaft sleeve, neck ringetc with necessary oiling and greassing and again transportation of the pump through vehicle from workshopto Rajouri E/M installations after necessary repair/replacement/maintenance including coupling (iron) cutting/drilling/grinding / making the bore and fixing the unique rubber coupling as required thickness in the existing if required andloading/unloading the pump and re-coupling the pump with motor on base frame, after checking of the alignment with motor, testing, commissioning complete all as directed by Engr-in-Charge. ( Note : Spare parts of pump i.e. ball bearing, stainless steel shaft, impeller, bush, cast iron keys will be measured and paid separately as supply only if required).
2Supply only cast iron impeller suitable for 150 HP capacity pump complete all as existing one
3Supply only Bush suitable for 150 HP capacity pump complete all as existing one
4Supply only CI key suitable for 150 HP capacity pump complete all as existing one
5Supply only stainless steel shaft suitable for 150 HP capacity pump complete all as existing one
6All as per srl item No-1 here in before but for pump capacity 40 HP to 50 HP.
7Supply only cast iron impeller suitable for 40 HP to 50 HP capacity pump complete all as existing one
8Supply only Bush suitable for 40 HP to 50 HPcapacity pump complete all as existing one
9Supply only CI key suitable for 40 HP to 50 HPcapacity pump complete all as existing one
10Supply only stainless steel shaft suitable for 40 HP to 50 HPcapacity pump complete all as existing one
11All as per srl item No-1 here in before but for pump capacity 15 to 30 HP .
12Supply only cast iron impeller suitable for 15 HP to 30 HP capacity pump complete all as existing one
13Supply only Bush suitable for 15 HP to 30 HPcapacity pump complete all as existing one
14Supply only CI key suitable for 15 HP to 30 HPcapacity pump complete all as existing one
15Supply only stainless steel shaft suitable for 15 HP to 30 HPcapacity pump complete all as existing one
16All as per srl item No-1 here in before but for pump capacity 5 to 10 HP .
17Supply only cast iron impeller suitable for 5 HP to 10 HP capacity pump complete all as existing one
18Supply only Bush suitable for 5 HP to 10 HP capacity pump complete all as existing one
19Supply only CI key suitable for 5 HP to 10 HP capacity pump complete all as existing one
20Supply only stainless steel shaft suitable for 5 HP to 10 HP capacity pump complete all as existing one
21Dismantling of 150HP motor and starter (Make : Kirloskar/Jyoti/BE/Crompton greaves/Bhart Bijlee/WPIL) from pump after disconnection of mechanical tyre coupling and unbolting from foundation base plate,discconection of electric connection from terminal/LT control panel, 3 phase, 415 volt loading/unloading the motor to vehicle and transportation of the motor from Rajouri E/M installations to workshop for repair / replacement, open the motor and cutting the burnt winding and clean the rotor & stator with CTC or other cleaning agent and re-winding of stator winding with super enamelled copper wire of gauge and turn as per existing,insulating the leads with insulating tubes and varnishing the stator with good quality of insulating varnish and after that,heating the stator in heat chamber for continuous two days for better insulation resistance. Re-assembling the stator & rotor carefully after replacement of worn out bearings as per existing and again transportation of the motor through vehiclefrom workshopto Rajouri E/M intallation including loading/unloading the motor on its base frame, connection of motor with pump with tyre coupling and fixing to the base frame by bolts. After checking up the alignment, testing of motor with megger for checking of insulation resistances, electric connection of motor to the control panel, testing on load for continous running for three hours complete all as specified and directed by Engr-in-Charge. (Note : Re-winding wire of new super enamelled coper wire of existing gauge/size/quality will be measured and paid separately as supply only).
22All as per srl item No-05 here in before but suitable for capacity of motor and starter 40 HP to 50 HP .
23All as per srl item No-05 here in before but suitable for capacity of motor and starter 15 HP to 30 HP.
24All as per srl item No-05 here in before but suitable for capacity of motor and starter 5 HP to 10 HP.
25Supply onlysuper enamelled copper wire of existing gauge/ size / quality to match with the existing as comply including all insulating material such insulating paper, sleeves, varnish etc drying the copper winding after varnish with blower or heater including soldering all internal connection and testing completeall as specified and directed.
26Supply only Ball bearing No 6305
27Supply only Ball bearing No 6308
28Supply only Ball bearing No 6309
29Supply only Ball bearing No 6312
30Supply only Ball bearing No 6316
31Supply only Ball bearing No 7311
32Supply only Roller bearing No NU 307
33Supply only Roller bearing No NU 411
34Supply only Roller bearing No NU 308
35Lifting out and lowering ofsubmersible pump set Capacity 03 HP of any make from bore well for carrying out repair in civil workshop including transportation and dismantling/repair of pumpset by taking out old unserviceable parts (nick ring, bush, steel sleeves, bowl assembly, coupling for pump and motor) cutting and removing old burnt copper winding from submersible motor and rewinding of motor with super enameled copper winding wire of same gauge and size including insulation etc. lowering the same after repair/replacementand testing complete all as directed. (Note : Spare parts of pump/motor i.e. ball bearing, stainless steel shaft,bush, cast iron keys, re-winding wire of new super enamelled coper wire of existing gauge/size/quality will be measured and paid separately as supply only if required).
36Supply only Bush suitable for 3HP capacity pump set complete all as existing one
37Supply only impeller suitable for 3HP capacity pump setcomplete all as existing one
38Supply only stainless steel shaft suitable for 3HP capacity pump set motor complete all as existing one
39Lifting out and lowering ofsubmersible pump set Capacity 25 HP of any make from bore well for carrying out repair in civil workshop including transportation and dismantling/repair of pumpset by taking out old unserviceable parts (nick ring, bush, steel sleeves, coupling for pump and motor) cutting and removing old burnt copper winding from submersible motor and rewinding of motor with super enameled copper winding wire of same gauge and size including insulation etc. lowering the same after repair/replacementand testing complete all as directed. (Note : Spare parts of pump/motor i.e. ball bearing, stainless steel shaft,bush, cast iron keys, re-winding wire of new super enamelled coper wire of existing gauge/size/quality will be measured and paid separately as supply only if required).
40Supply only Bush suitable for 25HP capacity pump set complete all as existing one
41Supply only impeller suitable for 25HP capacity pump setcomplete all as existing one
42Supply only stainless steel shaft suitable for 25HP capacity pump set motor complete all as existing one
43S&F for new super enameled copper wire of existing size/gague/quality after taking outold/ existing burnt/worn out contact point forfixed and moving contactsuitablesize/shape star delta starter for 15to 40 HP capacity motor complete all as specified
44All as per srl item No-21 here-in-before but capacity of motor 50 HP
45All as per srl item No-21 here-in-before but capacity of motor 100 HP to 150 HP.
46M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer with spray gun of existing colour shade on surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and as directed.
47M&L for applyingtwo coats of synthetic enamel paint over a coat of red oxide primer with spray gun of existing colour shade on surfaces of any description, n. exc. 60cm girth including holderbats, distance pieces, etc (length measured over bends, branches etc) complete all as specified and as directed.
48M&L for writing letters or figures (Block, Roman, Italic or Indian) n. exc. 30cm high with white paint complete all as specified and directed.
49M&L for painting stops, commas, short lines, dashes, hyphens, brackets etc with white paint complete all as specified and directed.
50Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 95 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE)
51Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 70 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE)
52Excavation in trenches not exc 1.5m wide and and not exc. 1.5m depth wide in hard/dense soil for laying electric cables/pipes etc including getting out excavated earth and trimming the sides and bottoms of trenches complete all as specified and directed.
53Supply and filling sandfor cushioning of cable protection in two layers ie. First layer 18cm before laying of cable and second layer 15 cm thick after laying of cable in trenches/ ductincluding spreading, levelling, punning down complete all as specified and directed.
54Supply and lay burnt class B bricks best quality localy available for cable protection complete all as specified and directed.
55Returning, filling in including spreading, leveling, watering and well ramming in layers not exc. 25cm in hard and dence soil complete all as specified and directed.
56Removal of surplus soil to a distance not exc. 50m and depositing where directed at a level not ex. 1.5m above the starting point complete all as specified and directed.
57S&F for 200mm bore CI sluice valve class PN-1.6, heavy duty ISI marked as per (IS-14846) with flanged ends with 02 Nos of rubber gaskets, nut, bolts and washers etc alongwith stainless steel spindle and operating wheel complete after taking out old unserviceable sluice valve with fitting etc all as specified and directed.
58All as per the description of srl item No-35 here in before but size 150mm bore
59All as per the description of srl item No-35 here in before but size 100mm bore.
60All as per the description of srl item No-35 here in before but size 80mm bore.
61S&F for On load change over switch of sheet steel enclosure confirmingSS Enclosure,front operated 4Pole 415 V, 50 Hzof Capacity 125Amps complete as in repair all as specified and directed.
62S&F for Onload change over switch of sheet steel enclosure confirmingSS Enclosure, front operated 4Pole 415 V, 50 Hzof Capacity 400Amps complete as in repair all as specified and directed.
63S&F for Onload change over switch of sheet steel enclosure confirmingSS Enclosure, front operated 4Pole 415 V, 50 Hzof Capacity 100Amps complete as in reapir all as specified and directed.
64S&F for moulded case circuit breakers with fixed thermal magnetic setting. MCCB 3Pole, 160 Amps, 36KA, 415 V, 50 Hz complete as in reapir all as specified and directed.
65S&F for moulded case circuit breakers with fixed thermal magnetic setting. MCCB 3Pole, 200 Amps, 36KA, 415 V, 50 Hz complete as in repair all as specified and directed.
66S&F for moulded case circuit breakers with fixed thermal magnetic setting. MCCB 3Pole, 400 Amps, 36KA, 415 V, 50 Hz complete as in repair all as specified and directed.
67M&L for construction of brick masonry new valve pit chamber of size 900mmx900mmx900mm (internal) size, 100mm thick PCC 1:4:8 type D2 lean concrete foundation using 40mm graded stone aggregate, providing well burnt brick masonry wall of 230 mm thick, built in CM 1:6, 15 mm thick rendering in cement mortar 1:4, finished even and smooth without using extra cement internally and externally and providing 3.15 mm thick MS sheet steel cover fixed on 50mmx50mmx6mm thick angle iron frame, embbeded in PCC copingwith locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate Standard size and MS hold fast and handle made out of 25 x 6mm flat iron, appplyingtwo coats of synthetic enamel paint of approved shade, over a coat of primer (Red Oxide zinc chrome) to all exposed surface of sheet and making good all disturbed surface complete after dismantling old unserviceable valve chamber all as specified and directed.
68S&F for glow sign boardbacklight in box printed on polycarbonated sheet PVC of Size 4.5 X 3 X 1/2 feet size with LED light fitting (02 nos 4 feet light fittings) complete as in repair all as specified and directed.
69Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground levelconnected to and including 32X6mm thick galvanised iron strip by means ofbolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete inclulding taking down existing unserviceable earthing all as specified and directed. (Note:-Earth strip and protection pipe upto 7.5mtr is included in the rate quoted)
70S&F for galvanised iron strip 32x6 mm buried in ground and on wall surface as per site requirement (for additional earthing lead beyond 7.5 meters per earth, if so required at site ) and interconnection of earth pits complete including removal of old unserviceable all as specified and directed.
71S&F for 200 mm bore cast iron non return valve, heavy duty with gun metal sheet, both end flanged including making flanged joint, rubber gasket, nuts, bolts and washers ISI marked, class PN- 1.6 conforming to IS-5312 (Part-2)-1986 complete after taking down old unserviceable non-return valve of any type all as specified and directed.
72All as per ser item no.49 above but of size 150mm dia.
73All as per ser item no.49 above but of size 100mm dia.
74All as per ser item no.49 above but of size 80mm dia.
75S&F for DOL starter, AC 3 phase, 415 Volt, 50 Hz with sheet metal enclosure type suitable for 05 HP motor including making connection complete as in repair all as sepcified and directed.
76SS&F for fully Automatic Star-delta starter, AC 3 phase, 415 Volt, 50 Hz with sheet metal enclosure type suitable for 10 HP motor including making connections complete as in repair all as sepcified and directed.
77All as per srl item No 53 above but for 30 HP motor
78All as per srl item No.53 above but for 40 HP motor
79All as per srl item No.53 above but for 50 HP motor
80All as per srl item No.53 above but for 150 HP motor
81M&L for mild steel work including cutting, bending to shape, welding drilling holes, jointing by nuts, bolts, washers etc using MS chanel, equal angle, flat iron, sheet steel etc complete as in repair all as directed.
82S&F for 20 mm bore gunmetal gate valve (ISI marked) heavy duty with iron wheel head, screwed both ends for iron pipe complete as in repair all as specified and directed.
83All as per serial item No-59 here-in-before but size 25 mm dia bore
84All as per serial item No-59 here-in-before but size 40 mm dia bore
85All as per serial item No-59 here-in-before but size 50 mm dia bore
86M&L for 16 sqmm, 3 core submersible copper conductor multistranded cable, LT 1100volt grade,water proof lowering with the column pipe into the bore/ well and testing complete after taking down old unserviceable cable.
87M&L for 10 sqmm, 3 core submersible copper conductor multistranded cable, LT 1100volt grade,water proof lowering with the column pipe into the bore/ well and testing complete after taking down old unserviceable cable.
88Supply and laying or fixing or passing through pipe, 1100voltsgrade heavy dutycablewith PVC insulated multi strand copper conductor cable size 95 Sqmm, single core unsheathed flexible complete after taking down old unserviceable cable all as specified and directed.
89Supply and laying or fixing or passing through pipe, 1100voltsgrade heavy dutycablewith PVC insulated multi strand copper conductor cable size 35 Sqmm, single core unsheathed flexible complete after taking down old unserviceable cable all as specified and directed.
90Supply, installation, commissioning and testing of LT Feeder pillar offactory made (CPRI approved), outdoor cubical compartmental type, double door, both side openable with hinged doors & locking arrangement,outgoing cable chamber with same rated aluminium strip from cable chamber to MCCB output, made out of 3.15 mm thick mild steel CRCAsheet supported and fixed on structural frame of angle iron of size50 x50 x 6mm angle iron frame including painting to all internal & external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground but PCC foundation (1:2:4) type B1, with danger notice plate (02 Nos) of 1.6mm thick mild steel sheet of size 20cmx15cm, vitreous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, suitable for 3 phase 4 wire system 415 volts grade consisting of copper bus bar capacity of 200 Amps with necessary wiring with PVC sheathed stranded copper conductor of 1100 volts of appropriate length size with and including fixing lugs, bolts, screws etc completeand comprising of the following accessories:- INCOMING :- (a) MCCB, 160 Amp, 4 Pole,36 KA - 01 No. (b) Digital Combimeter (7in1) with 4 digit LED Display -01 No (c) Neon Indicating lamp LED type one set in incoming phases(yellow, blue, red)-01set(set of three). OUTGOING:- (a) MCCB, 100 Amp, 4 Pole, 36 KA - 01 No.(b) MCCB, 63 Amp, 4 Pole, 36 KA - 01 No.(c) Spare space providedfor MCCB 63 only -01 No (Notes : Make of panel, size and drawing shall be got approved from GE before placing order for procurement)
91Servicing of diesel pump capacity 63 BHP and taking out the all defective/unserviceable parts as mentioned in note below and re assembling the same after replaced and testing complete all as specified and directed. (Note- Rates of all spare parts of (a) Diesel filter (b) Oil filter (c) Oil pressure gauge (d) Hose pipe set with clamps & clips, etc complete are inclusive of this item.
92S&F for 0.5 HP water pressure pump with all fittings for connection of pump complete all as specified and directed by Engr-in-Charge
93S&F for cable tray 150mm wide x 100mm deep with coupler plates, hot dip galcanised with standerd slot pattern thick duly pre-treated with hot dip galvanised in seven tank process, perforated type including provision of fixing arrangment, nuts & bolts etc for proper securing to walls/beams or suspended from ceiling or along with road with mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 type B1 (using 20mm graded stone aggregate) in foundation after taking down old unserviceable cable tray with fittings etc complete all as specified and directed.
94Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail