Public Administrative Department Local Bodies Closing in 0 days TDR #33173560

Construction Of Common Kitchen At Municipal Hindu Primary School Gandhi Nagar Newtown In Vaniyambadi Municipality

Issued by Local Bodies · vaniyambadi, Tamil Nadu
Tender Value
23.60 Lakhs
Estimated cost
Bid Submission
26 Jul 2022
0 days left
EMD
23600
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
vaniyambadi → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Common Kitchen At Municipal Hindu Primary School Gandhi Nagar Newtown In Vaniyambadi Municipality

BOQ

Name of Work: Construction of additional 2 class room ground floor Block A at Municipal Higher secondary School Gandhi Nagar
Sl. No. Item Description
1Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrockrequiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum
2Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification.
3Supplying and filling in foundation andbasement with filling sand in layers of not more than 15cm.thick well rammed watered and compacted etc., complete complying with standard specification.
4Supplying and filling inbasement with Gravel in layers of not more than 15 cm thick, well rammed watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
5Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification
6Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38
7Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38-slab , beam , lintel-slab , beam , lintel
8Column
9Reinforced Cement concrete 1:1.5 :3 (one cement, one and half sand & three course aggregate) using 20mm gauge hand broken/ and broken granite stone for all RCCitemsof works excluding centering shuttering and cost of reinforcement but including curing etc.,complete and alsoincluding fixingfan clamps and fixtures in rccworkswherever necessary as directed by departmentalofficer etc., complete-In foundation and basement
10In Ground floor
11Suppling and fabricating and placing in position MS(or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost ofsteel and binding wire also in all floors.
12Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9\"X43/8\"X 2 3/4\" including finishing, curing, etc., complete complying with standard specification - 100CFT-In Cement Mortar 1:5 Foundation
13In Cement Mortar 1:5 Ground Floor
14Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed-25mm thick precast slab using 10mm HBGS jelly
15Brick Partition Walls using II class ground moulded chamber bricks of size 9\"X43/8\"X 23/4\"in C.M 1:3using hoop iron reinforcement,if found necessary standard specification including finishing, curing,etc., complete complying with standard specification - 10 sqm-In Ground Floor
16Supplying and fixing in position Cement basedhydrualically pressed Anti-Skid tiles (pattern design) 20 mmthick in cement mortar 1:3 - 20mm thick & pointedwith same colour of cement etc., complete as per standard specification
17Providing Wall Black Board in two layers of cement mortar plaster in cement mortar 1:5 (one cement and five sand), 20mm thick and second layer of combination mortar 1:1:6 (cement, lime and sand), 20mm thick and providing border all-round the black board in cement mortar 1:5 (one cement and five sand), 20mm thick and making the surface smooth including painting with best approved quality of black oxide paint for black board etc., complete complying with standard specifications.
18Providing & fixing PVC RAIN WATER DOWNFALL PIPE of the following dia with necessary T.W.Clamps Plugs, Shoes,Bemds, other clamps, screws nails etc.,complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of \"U\" clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm]-110 mm dia (In building with ground floor only)
19Supply and Delivery Fabrication of MS doors and windows with outer frame and shutter frame in MS angle of size 40mm x 40mm x 6mm with MS flat 25mm x 25mm x 6mm and MS sheet of 18 guage including ventilating arrangements using 20mm square MS rods with locking arrangements including two coats of approved enamel paint over coat of red oxide including cost of angles, plates, sheets, fabrication charges, cost of hold fast and transportation charges etc., complete-Fully pannelled Double leaf-Door (1.00 m x2.10 m)
20Fully pannelled Double leaf-Window(without Ventilator)(1.20 m x 0.90 m)
21Plastering with cement mortar 1:3,10 mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306)
22Plastering with cement mortar (1:5) 12mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306)
23White washing two coats with freshly burnt shell lime white in colour in all floors including cost of lime and other materials brushes scaffolding charges etc.complete complying with standard specification and as directed. -100sq.m S.I.333
24Painting 2 coats with approved cement paint over cement plastered wall surface, ceiling and other new surface and including cleaning, preparing the surface and curing etc., complete.
25Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being \"32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum
26Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
27Earthing as per P.W.D standard with an earth electrode of 2 Mtr. Class \"B\" GI pipe of dia not less than 32mm complete with necessary masonry work.SD 234
28Supply and run of 2 of No.8 SWG GI wire for guarding with cradle with No.8 SWG GI wire at the equal interval of 1.5 Metre. SD.75
29Supply and run of 2x1.5sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in 25mm dia GI pipe (Class \"B\") suitably bent at both ends with necessary angle iron upright and end supports for mains SD 69
30Wiring with 2x4 sqmm(56/0.3) PVC insulated SC unsheathed Cu.Conductor cable of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with 150mm x100mm x113mm TW switch box in flush with wall with 3mm thick hylem sheet cover for 15 A 3 pin flush type non inter locking Wall socket with 15A Flush type switch with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC power plug point. SD 41
31Wiring with 2x1.5sqmm(22/0.3) PVC insulated unsheathed SC. Cu.Conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A F.T. switch inflush with wall, covered with hylum sheet of 3mm thick with painting of suitable colour for open PVC light / fan point (For electronic regulator) (5 Points Per Coil) SD 22
32Supply and fixing of 5A/15 A 3 Pin combined flush type wall socket with 15A flush type switch concealed in suitable MS Box flush with wall with painting.SD 137
33Supply and fixing of 1200 mm sweep AC ceiling fan complete with stepped electronic 300W regulator with the existing down rod on the existing clamps. (SD 112)
34Supply and fixing of single box type 4\"36 W flu fitting complete with electronic ballast with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting.SD 87
35Supply and fixng of TNEB Moter Board suitable for 3 Phases 63A service connection made up of suitable angle iron frame work of size 2 feet x 1 1/2 feet using angle iron of size 1 1/2\" x 1 1/2\" x 1/4\" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos 63A fuse units (500V) 1 No. Neutral link, copper earth flat of size 1\" x 1/4\" with inter connection of EB meter to fuse units by 7/16 PVC insulated copper wire with earth connection complete .SD 129

AI Tender Summary

OUR REF NO 33173560
AUTHORITY Local Bodies
TENDER VALUE 23.60 Lakhs
LAST DATE 26-07-2022
Authority
Authority Name Municipalities
Work Description Construction Of Common Kitchen At Municipal Hindu Primary School Gandhi Nagar Newtown In Vaniyambadi Municipality
Basic Detail
Tender No 1282/2022/E1
Bidding Type Tender
Location
City vaniyambadi
State Tamil Nadu
Key Dates
Publish Date 20 Jul 2022
Submission Date 26 Jul 2022
Open Date 26 Jul 2022
Finance
Tender Value 23.60 Lakhs
Tender Fee Ref. Documents
EMD 23600
Exemption Not Available
Document List
Tendernotice_1.pdf
d02991cd-3a6d-4035-94de-88d6f8b642f6.html
BOQ_287118.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 20, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 26, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 26, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

d02991cd-3a6d-4035-94de-88d6f8b642f6.html

xls

BOQ_287118.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders