| 1 | M&L for cleaning of WCs and cleaning of sewage line from gully trap to 1st manholes day to day basis as per complaint slip on working day only by manually including all necessary T&P complete all as specified and directed . |
| 2 | Desludging of septic tank including sludgepits etc manually for cleaning them throughly and removing muddy soils/sludge to a distance not exc 500mtr and buried it in pits or otherwise disposed off out side defence landincluding dewatering of efflorescents from septic tank,etc by means of 7.5 HP non clogging diesel driven pump with necessary disel, T&P etc in nearest draincomplete all as specified and directed for the following sizes:- |
| 3 | 10 - 25 users septic tank |
| 4 | 50 users septic tank |
| 5 | 100 users septic tank |
| 6 | 150 users septic tank |
| 7 | Dittoall asserial item No 2.00above mentioned here in before but man holes of any depth and any size. |
| 8 | Cleaning of sewage line for 150 mm bore of pipes and connected manholes(any length) from manhole to manhole, manhole to septic tank septic tank to soakwell (length not exc 50 mtr) by roding and well flushing after cleaning and removing mud / sludge etc and burried it in pits and disposed off the same outside defence area complete all as specified and directed. |
| 9 | Dewatering of efflorescents from septic tank / soak well etc of any capacity by means of 7.5 HP non clogging diesel driven pump with necessary diesel oil, T&P etc in nearest drain complete all as specified and directed.Note :Date and time of the dewatering shall be entered in register and signed by contractor, JE (Civil) and Engineer in charge for record of measurements. |
| 10 | M&L for cleaning of sludge of any type from drain and clear toflow of water as directed including removing theexcavated sludge n.exc. 50 m and depositing where directed at a level to a distance n.exc. 1.5 m above the starting points complete all as specified and directed. |
| 11 | Cutting out any type of vegetation complete from root grouted inside the wall specially in contact with sanitary pipe and pouring/grounting with hydrochloric acid (HCL) on left out roots if any including making good surfaces to match adjacent surfaces in PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) or 15mm thick plaster in CM (1:4)area exc. 0.5 Sqm but n.exc. 1.0 Sqm each complete all as specified and directed. |
| 12 | Cleaning and removing all scale and dirt, etc. from PVC water tanks of capacity exc 250 ltrs and not exc 500 ltrs and from mouths of circulating pipes, etc.complete all as specified and directed . |
| 13 | S&Fin repair 110 mm bore PVC (SWR) bends any radiuscomplete all as specified and directed. |
| 14 | S&Fin repair 75 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 15 | S&F in repair 110 mm bore PVC (SWR) branch piece , single (Single Y) equal or unequal complete all as specified and directed. |
| 16 | S&F in repair 75 mm bore PVC (SWR) branch piece , single (Single Y) equal or unequalcomplete all as specified and directed. |
| 17 | S&F in repair 110 mm bore PVC (SWR) junctions, single (Single T) equal or unequal complete all as specified and directed. |
| 18 | S&F in repairs 110 mm bore PVC (SWR) vent cowlcomplete all as specified and directed. |
| 19 | S&F in repair 75 mm bore PVC (SWR) vent cowlcomplete all as specified and directed . |
| 20 | S&F in repair 110 / 110 mm bore PVC (SWR)\"P\" trapcomplete all as specified and directed . |
| 21 | S&F in repair 110 / 110 mm bore PVC (SWR) \"S\" trapscomplete all as specified and directed. |
| 22 | S&Fin repair 75 mm dia PVC(SWR)floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 23 | S&F in repairs 75mm dia PVC (SWR) pipes single sockedted in any length with rubber ring joints, laid in trenches or in floorscomplete all as specified and directed .(Note : Earth work will be measured & paid separately |
| 24 | S&F in repairs 110mm dia PVC (SWR) pipes single sockedted in any length with rubber ring joints, laid in trenches or in floorscomplete all as specified and directed . (Note : Earth work will be measured & paid separately |
| 25 | S&F in repairs 110mm dia PVC (SWR) pipes single sockedted in any length with rubber ring joints, fixed to walls complete all as specified and directed. |
| 26 | S&F in repairs 75mm dia PVC (SWR) pipes single sockedted in any length with rubber ring joints, fixed to walls complete all as specified and directed. |
| 27 | Demolition of reinforcement cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 28 | M & L for providing pre-cast cement concretecover slabs (for drain/ man holes etc) and similar items with plain faces in cement concrete 1:2:4 typeB-1, using 20 mm graded stone aggregate and setting in cement mortar 1:6 including necessary form work complete all as specified and directed. |
| 29 | M&L for Mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specifed and directed. |
| 30 | M&L for Mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specifed and directed. |
| 31 | Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 32 | M & L for Cement concrete type B-1, 1:2:4 (20mm graded aggregate) 100 mm thick in floors complete all as specified and directed. |
| 33 | Demolition of brick work built in cement mortor including all quions arches pillar etc. but excluding concrete arches complete all as specified and directed. |
| 34 | M&L forbrick work with sub class \"B\" bricks (old size) straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specifed and directed. |
| 35 | M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 and finished even and smooth (without using extraor cement) complete all as specified and directed. |
| 36 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc. or for shafts, cesspits, manholes, pier holes etc. n.exc 10 sqm on plan and n.exc 1.5 mtr in depth and getting out in soft / loose soil complete all as specifed and directed. |
| 37 | Returning filling in, including spreading levelling watering and well ramming in layers not exc 25 cm in soft / loose soil complete all as specifed and directed. |
| 38 | Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specifed and directed. |
| 39 | Demolition and breaking up drain pipe (salt glazed stoneware/RCC) 150 mm dia of pipe set in cement mortor and taking out from trenches / walls complete all as specifed and directed. |
| 40 | Demolition and breaking up drain pipe (salt glazed stoneware/RCC) 200 mm dia of pipe set in cement mortor and taking out from trenches / walls complete all as specifed and directed. |
| 41 | M&L for cement concrete bed to drain pipes in cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) including packing under and haunching against the sides of pipe 200 mm dia after they are laid and tested complete all as specified and directed. |
| 42 | M&L for cement concrete bed to drain pipes in cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) including packing under and haunching against the sides of pipe 200 mm dia after they are laid and tested complete all as specified and directed. |
| 43 | M&L for salt glazed stone ware drain pipes 150 mm internal dia of pipes laid in trenches and jointed in CM (1:1) complete all as specified and directed. |
| 44 | M&L for salt glazed stone ware drain pipes 200 mm internal dia of pipes laid in trenches and jointed in CM (1:1) complete all as specified and directed. |
| 45 | M&L for providing cement concrete (1:4:8) type D-2 (using 40 mm graded stone agregate) as in foundation, filling and mass concrete complete all as specifed and directed. |
| 46 | M&L for providing cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in coping, water toughs including weathering, slighting rounded or chamfered angles and throating including necessary form work all as directed and specified. |
| 47 | M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in surface channels and drains complete all as specifed and directed. |
| 48 | M&L for rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces,second layer (finishing coat)mixed with liquid water proofing compound @ 200 ml / 50 Kg bag of cement as per manufacturer\"s instructions and finished the surfaces even and fair without using extra cement complete all as specified and as directed..Note:Liquid WPC will be measured and paid separately. |
| 49 | Supply only integral water proofing compound (Liquid). |
| 50 | M&L forapplying two coat of cement base paint on prepared new wall surfaces over a coat of primer on wall including preperation of new surfaces etccomplete all as specified and directed. |
| 51 | M&L 75mm thick PCC 1:3:6 type C-2 using 20mm graded aggregate as in plinth protection/ flooring etcfinishing even & smooth without using extra cementcomplete all as spd and directed. |
| 52 | S&F in repairs vitreous china hand wash basin, white, flat back of size 450X300 mmincluding brackets complete all as specified and directed . |
| 53 | S&F Brass CP towel rail 20mm dia `D\" type 60 cm long between flanges complete all as specified and directed. |
| 54 | S&F in repair 450mm long PVC connectionwith PTMT nuts and fixed to iron pipe of size 15mm etc complete all as specifed and directed. |
| 55 | S&F 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers including providing 40 mm wide PVC beading alround of design approved by Engr-in-Charge. |
| 56 | S&F in repair bib tap of 15 mm size standard or PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm 90gms/20mm-125gms) etc complete all as specified and directed |
| 57 | S&F in repair PVC valve less, syphonic action type flushing cistern of 10 ltr capacity,low level with inlet, ball valve, float and handle including bracketsincl PVC connection with CP brass nuts on both sides complete all as specified and directed . |
| 58 | S&F in repair Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoistedand fixed in position all as specified in SSR Pt-Iof 500 Ltr capacity including CP tank nipple complete all as specified and directed. |
| 59 | S & F in repair PVC ball valve 20mm dia with epoxy coated aluminium rod and high density ball (minium weight 210 gms) complete all as specified and directed.Make- Prayag/Polytuff. |
| 60 | M&L in repair 75 mm dia of cast iron nahani trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete all as specified and directed. |
| 61 | S&F in repair vitreous china squatting pan, Orissa pattern size 580 x 440 mm white with integral foot rest incl connection to trap, and to flush pipe, anti-syphonage etc including making good to floor complete all as specifed and directed. |
| 62 | S&F in repair vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolt, flushing cistern and flush pipe) but including sheet cover ofwhite colourcomplete all as specified and directed . |
| 63 | S & F in repair Vitreous China half stall type urinals,white with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (excluding of fixing supply pipe, flushing cistern, flush pipe, trap and waste pipe) complete all as specified and directed. |
| 64 | S & F CP Urinal spreader for fixing with 15mm bore pipe complete all as specified . |
| 65 | M & L for sand filling under floors or in foundations including watering and consolidation as required complete all as specified and directed.. |
| 66 | M&L old size brick work with sub class \"B\" brickslaid flat in floors laid in drycomplete all as specified and directed. |
| 67 | M & L for providing 100 mm thick cement concrete 1:3:6 type C-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor complete all as specified and directed. |
| 68 | M & L for providing 50 mm thick cement concrete 1:2:4 type B-1 (using 20 mmgraded stone aggregate) as in floor, laid in panels and position to conform to design and finishing top surface even and smooth with using extra cement complete all as specified and directed.. |
| 69 | M & L old size brick work with sub class \"B\" bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6complete all as specified and directed.. |
| 70 | M&L 15 mm thick cement plaster on fair faces of bricks work or concrete surfaces with cement mortar 1:6 finished even and smooth (without using extra cement)complete all as specified and directed. |
| 71 | M&L for prepration of newly plastered surfaces and applying three coats of white wash on wall surfaces complete all as specified and directed. |
| 72 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed. |
| 73 | M & L for Non skid ceramic coloured tiles (square / rectangular) of 7 to 8 mm thick, area of each tile exceeding 0.11 sqm but not exc. 0.18sqm as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 74 | M & L for Glazed ceramic coloured tiles of size 300 mm X 200 mm X 7 mm thick as on vertical surfaces such as skirting, dados and rises to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including 10 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 75 | M&L For Chequred cement concretetiles 20cmX20cmX25mm thick, set jointed and pointed with grey cement slurry mixed with pigment to match the shade over and inclusive of 20mm thick screed bed of CM(1:6)complete all as specified and directed byEngr -in charge. |
| 76 | S& F MS post and strutin fencing includingcutting top to shape as directed ,driling holes ,notching for wire etc ,flat ironfillet (for securing wire mess etc)including all necessary drilling holes, notchingor riveting etc,and similar work conforning to Fe-410 or FE-310 complete all as specified and directed. |
| 77 | S&F IN repair chain link fencing in 4mm dia galvansied steel wire n.exc 4 kg per sqm 100 x 100 mm diagonal shape, mesh, made up, including link line wire, in fencing including straining and fixing to wood, concrete or steel posts and or to straining bolts, including securing with and provision of galvanised iron tying wire galvanised iron staples or steel pins etc complete all as directed by Engr-in-Charge.Note:- Actual weight of chain link fencing shall be ascertain by BOO by GE. |
| 78 | S&F in repair for galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standered rails straining bolts including securing or typing at crossing with and provision of galvanised MS wire stapples or steel pins etc as directed (each line wire to be measured) |
| 79 | M&L two coat synthetic enamel paint over a coat of red oxide primer on steel surfaces of any description over 10 cm in width or girth not otherwise described including preparation of steelsurfaces complete all as spd and directed . |