Jjm 2021 24 Cwss To Pallickkal Madavoor Navaikulam Panchayaths Phase Ii Supplying Laying Jointing Testing And Commissioning Of Distribution Networks And Providing Fhtcs In Zone Iii In Pallickkal And Madavoor Panchayaths Part Iiia Jjm 2021 24 Cwss To Palli
Tender Overview
Project Description
Jjm 2021 24 Cwss To Pallickkal Madavoor Navaikulam Panchayaths Phase Ii Supplying Laying Jointing Testing And Commissioning Of Distribution Networks And Providing Fhtcs In Zone Iii In Pallickkal And Madavoor Panchayaths Part Iiia Jjm 2021 24 Cwss To Pallickkal Madavoor Navaikulam Panchayaths Phase Ii Supplying Laying Jointing Testing And Commissioning Of Distribution Networks And Providing Fhtcs In Zone Iii In Pallickkal And Madavoor Panchayaths Part Iiia
BOQ
| Sl. No. | Item Description |
| 1 | Working Charges |
| 2 | Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffice diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation. |
| 3 | Dismantling of flexible pavement ( bituminous courses ) by mechanical means and disposal of dismantled material up to a lead of 1 kilo metre, as per direction of Engineer-in-charge. |
| 4 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 5 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil (Ref. Item No. 2.10.1 of DSR) |
| 6 | \"Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : HardRock(Blasting Prohibited)(Ref. Item No. 2.13.3 0f DSR) |
| 7 | Fencing one side of trenches, 1.50 m height with two rows of 10 cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2 m intervals. (Data Prepared based on PWD SDB - Item No.1009) |
| 8 | Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials).160 mm nominal outer dia pipes. |
| 9 | Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials). 90 mm nominal outer dia pipes.\" |
| 10 | Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials).110 mm nominal outer dia pipes. |
| 11 | Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials).63 mm nominal outer dia pipes. |
| 12 | Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials) 50 mm nominal outer dia pipes. |
| 13 | Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329excluding cost of pipes and specials : 150 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.16 in DAR |
| 14 | Conveying and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536excluding cost of pipe and specials: 200 mm dia pipe Data derived from 18.27.4 in DAR |
| 15 | Conveying and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536excluding cost of pipe and specials: 250 mm dia pipeData derived from 18.27.5 in DAR |
| 16 | Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:200 mm dia pipes |
| 17 | Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:250 mm dia pipes |
| 18 | Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:150 mm dia pipes |
| 19 | Labour for cutting C.I. pipe with steel saw.200 mm diameter C.I. pipe |
| 20 | Labour for cutting C.I. pipe with steel saw.250 mm diameter C.I. pipe |
| 21 | Labour for cutting C.I. pipe with steel saw.150 mm diameter C.I. pipe |
| 22 | Testing 150mm DI/CI pipelinewith potable water to the required test pressure 150 mm diaObserved Data derivedfrom item no.1018 of PHED DATA |
| 23 | Testing 200mm DI/CI pipeline with potable water to the required test pressure 200 mm dia Observed Data derived from item no.1020 of PHED DATA |
| 24 | Testing 250mm DI/CI pipeline with potable water to the required test pressure . 250 mm dia Observed Data derived from item no.1022 of PHED DATA |
| 25 | Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :up to 600 mm dia |
| 26 | Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :up to 600 mm dia |
| 27 | Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 100 mm dia nominal bore Observed Data derived from item no.18.12 of DAR |
| 28 | Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work40 mm dia nominal bore |
| 29 | Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work50 mm dia nominal bore |
| 30 | Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work80 mm dia nominal bore |
| 31 | Conveying and fixing C.I. sluice valves (with cap)by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :250 mm diameter. Class II\"Data derivedfrom item no.18.31.5.2of DAR |
| 32 | Conveying and fixing C.I. sluice valves (with cap)by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) : 150 mm diameter. Class II\"Data derivedfrom item no.18.31.3.2of DAR |
| 33 | \"Conveying and fixing C.I. sluice valves (with cap)by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :80 mm diameter. Class II\"Observed Data derivedfrom item no.18.31.of DAR |
| 34 | Conveying and fixing C.I. sluice valves (with cap)by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :100 mm diameter. Class II\" Data derivedfrom item no.18.31.1.2of DAR |
| 35 | Conveying and fixing C I Single acting AirValve of approved qualitywith bolts,nuts,rubber insertions etc . excluding the cost of airvalve(the tail pieces if required will be paid seperately): 25 mmSingle acting Air Valve Observed Data derivedfrom item no.18.59.of DAR |
| 36 | Conveying and fixing C I Single acting AirValve of approved qualitywith bolts,nuts,rubber insertions etc . excluding the cost of airvalve(the tail pieces if required will be paid seperately):50 mmDouble acting Air Valve Data derivedfrom item no.18.59.1 of DAR |
| 37 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore |
| 38 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore |
| 39 | Fabricating MS pipes of size 150mm (ID) using 8 mm thick MS plate including cost and conveyance charges of MS plate, all fabrication charges, charges of painting thesteel work with two or more coat deluxe multi surface paint to give an even shade over an under coat of primer etc. complete: For pipes fabricated with 8mm thick MS plates. |
| 40 | Fabricating MS flanges of diameter 150 mm using 12 mm thick MS plateincluding cost and conveyance charges of MS plate, all fabrication charges, charges of painting thesteel work with two or more coat deluxe multi surface paint to give an even shade over an under coat of primer etc. complete: For pipes fabricated with 8mm thick MS plates. |
| 41 | Cutting 150mm (ID)MS pipes for making bends and other specialsby gas cutting including cost of gas, all labour and hire charges of tools etc. complete: For pipes fabricated with 8mm thick MS plates. |
| 42 | Welding150mm (ID) MS pipes for making bends and other specialsby gas/electric welding machine including cost of gas and welding rods ,all labour and hire charges of tools etc. complete: For pipes fabricated with 8mm thick MS plates. |
| 43 | Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:150 mm diameter pipe |
| 44 | Grinding cut and weld edges of 150mm (ID) MS pipes during fabrication work including all labour and hire charges of tools etc. complete: For pipes fabricated with 8mm thick MS plates. |
| 45 | Supply ,stacking,spreading and consolidating of Quarry Muck in the trench of pipe line, including carriage, loading ,unloading & stacking up to any lead. |
| 46 | Conveying the excavated rock from the site and stacking the same with an average distance of 5km by lorry ets as directed by the department officers |
| 47 | Construction of Valve Chamber,Anchor Blocks,CulvertCrossing and Miscellanious works |
| 48 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 49 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 50 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 51 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 52 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 53 | Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 54 | 12 mm cement plaster of mix:1:4(1 cement:4 fine sand) |
| 55 | Cost of Pipes and Specials |
| 56 | Supply of uPVC Pipe, IS 4985:2000 , 8kg/cm2, 160mm Dia. |
| 57 | Supply of DI K9 Pipe Conforming to IS 8329/2000, 150mm Dia. |
| 58 | Supply of DI K9 Pipe Conforming to IS 8329/2000, 200mm Dia. |
| 59 | Supply of DI K9 Pipe Conforming to IS 8329/2000, 250mm Dia. |
| 60 | Supply of uPVC Pipe, IS 4985:2000 , 8kg/cm2, 90mm Dia. |
| 61 | Supply of uPVC Pipe, IS 4985:2000 , 8kg/cm2, 110mm Dia. |
| 62 | Supply of uPVC Pipe, IS 4985:2000 , 8kg/cm2, 63mm Dia. |
| 63 | Supply of uPVC Pipe, IS 4985:2000 , 8kg/cm2, 50mm Dia. |
| 64 | Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 200mm. |
| 65 | Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 150mm. |
| 66 | Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 100mm. |
| 67 | Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm. |
| 68 | Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 25mm. |
| 69 | Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 50mm. |
| 70 | Supplying and fixing C.Iwith cover andframe for manholes: 560 mm diameter ( heavy duty) the weightto be not less than 208 kg |
| 71 | Supplying 100mm dia. GI medium pipe as per DSR(E&M) rate. |
| 72 | Supply of GI pipe fittings(5% of the cost of GI pipes). |
| 73 | Supplying all required PVC Specials such as bends, flanges, tailpiece, couplings, adaptors, reducers, end cap etc. and CID/CIR Joints as per directed.3% ofthe cost for PVC pipe. |
| 74 | House connections(FHTC's) |
| 75 | Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow,MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter,lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, includingthe cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. |
| 76 | Providing additional length of house connection pipe using20mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers. |
| 77 | Providing 20mm (1/2 inch) PVC Air Valve in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire for tools and labour charges etc. complete and as per the directions of the department officers. |
| 78 | Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers. |
| 79 | Feasibility assessment,geotaging uptodation of GIS map in the provided soft copy of the base map. Actual number of Functional House hold tap connection(FHTC) will fully depend upon this feasibility study. The house hold tap connection must be functional while having minimum storage of water in the service reservoir. The hard copies ( 3 sets in appropriate color, in laminated sheets ) and soft copies in CD to be submitted after execution of this work ( The available GIS maps as it is & where it is condition will be provided for the contractor for uptodation of submitted of GIS map) as per direction of dept. officials. (Geo tagging) |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender