Jaipur Vidyut Vitran Nigam Limited-JVVNL has published Award Of Central Rate Contract For Repair And Testing Of Beyond Gp Failed / Damaged Three Phase Distribution Transformer Of Assored Rating Award Of Central . Submission Date for this Tender is 04-08-2022. Distribution Transformer Tenders in jaipur Rajasthan. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | I) Loading/Unloading & opening of Transformer Cover,draining oil if any, detanking core and coil assembly ,assessment and estimation for repair and replacement of parts, cleaing andwashing of dust/rust and dirt from all other parts including core tanks and cooling tubes, retankingafter replacement of parts/repairs as required filling fresh/new filtered Transformer oiltaking of transformer for test and testing for all the routine test as in case of new transformer as per relevant ISS & after satisfactory repairs & testing, marking & providing blue paint etc.loading of transformers at the contractor"s works.(Price variable with base date 01.07.22) |
2 | ALUMINIUM WOUND DISTRIBUTION TRANSFORMERS |
3 | a) 10 KVA |
4 | b) 16/25KVA |
5 | c) 40 KVA |
6 | d) 63 KVA |
7 | e) 100 KVA |
8 | f) 160KVA |
9 | COPPER WOUND DISTRIBUTION TRANSFORMERS |
10 | a) 315 KVA |
11 | b) 500 KVA |
12 | II) Supply of following damaged parts requiring replacement complete in all respect |
13 | HV leg coils with insulation , varnishing and packing of coil assembly Vaccum impregnation/Oven dried) (Price variable with base date 01.07.22) |
14 | ALUMINIUM WOUND DISTRIBUTION TRANSFORMERS |
15 | ALL(For AL wound) |
16 | COPPER WOUND DISTRIBUTION TRANSFORMERS |
17 | ALL(For Cu wound) |
18 | HT Bushing(11 KV) as per relevent ISS |
19 | 10 kva to 500 KVA |
20 | LT Bushing (0.433 KV) & Neutral bushing as per relevent ISS |
21 | ALUMINIUM WOUND DISTRIBUTION TRANSFORMERS |
22 | 10 kva to 160 KVA |
23 | COPPER WOUND DISTRIBUTION TRANSFORMERS |
24 | 315 to 500 KVA |
25 | Bushing Rod and other metal parts including nuts( indicate material and size of bushing Rod) |
26 | i) For HV Bushing |
27 | 10 KVA to 500 KVA |
28 | ii) For LV bushing |
29 | ALUMINIUM WOUND DISTRIBUTION TRANSFORMERS |
30 | 10 kva to 160 KVA |
31 | COPPER WOUND DISTRIBUTION TRANSFORMERS |
32 | d) 315 KVA |
33 | e) 500 KVA |
34 | Set of Gaskets(Rubberised cork/ Neoprine) material & size is to be indicated |
35 | ALUMINIUM WOUND DISTRIBUTION TRANSFORMERS |
36 | 10 kva to 160 KVA |
37 | COPPER WOUND DISTRIBUTION TRANSFORMERS |
38 | 315 to 500 KVA |
39 | Breather ,dehydration |
40 | i)Silaca gel typewith fresh silica gel |
41 | ALUMINIUM WOUND DISTRIBUTION TRANSFORMERS |
42 | 10 kva to 160 KVA |
43 | COPPER WOUND DISTRIBUTION TRANSFORMERS |
44 | 315 to 500 KVA |
45 | Oil drain /filter valve(material & size is to be indicated) |
46 | 160 to 500 kva |
47 | Fresh/ new filtered transformer oil of standard quality with ISI mark ) (Price variable with base date 01.07.22) |
48 | For all type of Transformers |
49 | Sundry items viz. cover bolts, plug cap screw, washers, insulation material etc. Please indicate list of Item included in sundry item parts if any,(denting/ welding etc if required) |
50 | ALUMINIUM WOUND DISTRIBUTION TRANSFORMERS |
51 | 10 kva to 160 KVA |
52 | COPPER WOUND DISTRIBUTION TRANSFORMERS |
53 | 315 to 500 KVA |
54 | Dial type thermometer ( material & size is to be indicated) |
55 | ALUMINIUM WOUND DISTRIBUTION TRANSFORMERS |
56 | a)160 KVA |
57 | COPPER WOUND DISTRIBUTION TRANSFORMERS |
58 | b) 315 kva to 500 kva |
59 | Painting of Transformer |
60 | Inside with one coat with primer & two coat of Zinc Cromate best paint. |
61 | ALUMINIUM WOUND DISTRIBUTION TRANSFORMERS |
62 | a) 10 KVA |
63 | b) 16/25 KVA |
64 | c) 40 KVA |
65 | d) 63 KVA |
66 | e) 100 KVA |
67 | f)160 KVA |
68 | COPPER WOUND DISTRIBUTION TRANSFORMERS |
69 | a) 315 KVA |
70 | b) 500 KVA |
71 | Out side of transformer with primer andtwo coats of grey paint and marking after de rusting |
72 | ALUMINIUM WOUND DISTRIBUTION TRANSFORMERS |
73 | a) 10 KVA |
74 | b) 16/25 KVA |
75 | c) 40 KVA |
76 | d) 63 KVA |
77 | e) 100 KVA |
78 | f) 160 KVA |
79 | COPPER WOUND DISTRIBUTION TRANSFORMERS |
80 | a) 315 KVA |
81 | b) 500 KVA |
82 | Filteration charges of new transformer oil . (if supplied by nigam) |
83 | Meter and Protection (M and P )Box completeas per new design already adopted and in practice as per Enclosed drawings ( MCCB is not in the scope of contractor) |
84 | a) 10 KVA |
85 | b) 16/25 KVA |
86 | c) 40 KVA |
87 | Fixing Charges of Meter and Protection (M and P ) Box |
88 | a) 10 KVA |
89 | b) 16/25 KVA |
90 | c) 40 KVA |
91 | Bi Metal Connector (M-12) HT |
92 | Bi Metal Connector (M-12) LT |
93 | Pressure Release Valve (10 KVA to 100 KVA) including Labour charges. |