Repair/ Renewal/ Maintenance Of Pump Sets, Motor Starters, Lt Panels, Apfc Panels Dg Sets And Connected Items At Mil Station Solan Under Ge Kasauli , solan-Himachal Pradesh

Military Engineer Services-MES has published Repair/ Renewal/ Maintenance Of Pump Sets, Motor Starters, Lt Panels, Apfc Panels Dg Sets And Connected Items At Mil Station Solan Under Ge Kasauli . Submission Date for this Tender is 15-08-2022. Starter Tenders in solan Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33159598
Corrigendum : Repair/ Renewal/ Maintenance Of Pump Sets, Motor Starters, Lt Panels, Apfc Panels Dg Sets And Connected Items At Mil Station Solan Under Ge Kasauli
Open Tender
Indian
Himachal Pradesh
solan
15-08-2022

Tender Details

Repair/ Renewal/ Maintenance Of Pump Sets, Motor Starters, Lt Panels, Apfc Panels Dg Sets And Connected Items At Mil Station Solan Under Ge Kasauli

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Aug-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-08-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

BOQ Items

Name of Work:REPAIR/ RENEWAL/ MAINTENANCE OF PUMP SETS, MOTOR STARTERS, LT PANELS, APFC PANELS DG SETS & CONNECTED ITEMS AT MIL STATION SOLAN UNDER GE KASAULI.
Sl. No. Item Description
1Schedule "A" Section - I
2Disconnecting the electrical connections of motor, water supply to the Pump andtaking out pump after disconnecting both motor and pump mechanically 10 to 15 HP capacity,capacity - 45 Cum at 35 metres head installed atWater Pump House and Back Solan and transporting the same to an authorized workshop for following repairs :-
3S&F Shaft with keys made out of steel 410 grade for Srl Item No 1.00
4Shaft sleeve with nuts made out of stainless steel 410 grade for Srl Item No 1.00
5Set of pins and Gaskets made out of Mild Steel for Srl Item No 1.00
6Coupling set made out of Cast Iron including bolts, nuts, washers & rubber bushes for Srl Item No1.00
7Gland box made out of Cast Iron including gland box studs with nuts and washers for Srl Item No1.00
8Gland packing made out of Gr. Cotton for Srl Item No 1.00
9Impeller made out of cast Iron duly balanced by means of precision lathe machine for Srl Item No 1.00
10Driving End bearing for Srl Item No1.00
11Non Driving End bearing for Srl Item No 1.00
12Disconnecting the electrical and mechanical connections of motor, and taking out motor,15 HP capacity at Solan Pump House. Transporting the same to an authorized workshop for following repairs:-(a) Dismantling burnt AC 3 Phase, 50 Hz,motor, 15 HP taking out all coils and re-winding the motor complete with same gauge of wire and same nos of turns. Heating, Baking and varnishing the winding complete. Re-assembling the motor and fixing back in position all as directed by Engr-in-Charge and recommended by the manufacturer.
13All as per item No 2.00 here-in-before but for, 10 HP capacity .
14Supply & fixing in repairs Volt Meter Digital, 96 x 96 mm,0-500 Volts,Class 1, AC.
15Supply & fixing in repairs Amp Meter Digital, 96 x 96 mm,0-100 Amps,Class 1, AC.
16Supply & fixing in repairs die cast resin CT, Class 1, for digital Amp Meters. Ratio of CT- all as directed by Engineer- in-Charge.
17Taking out old & unserviceable power contactor and Supply & fix power contactor for S/D starter 15 HP 3 pole, 32 Amps for AC 3 rating 415 volts, 15 kW 50 Hz supply including control coil, 1NO+1NC, contact springs, spring retainers and arc runners complete.
18Taking out old & unserviceable power contactor and Supply & fix power contactor for S/D starter 10 HP ,3 pole,12 Amps for AC 3 rating 415 volts, 5.5 KW , 50 Hz supply including control coil, 1NO+1NC, contact springs, spring retainers and arc runners complete.
19Supply / laid PVC insulated unsheathed multistrandedHRFR 3 x single core ( R,Y,B) copper conductor 1100 volts gradeof size 16 sqmm passing through existing PVC/ERW conduit from starter upto pump fixed with required size of copper lugs complete all as specified and directed by Engr-in-Charge.( Note- 3 single core wire of 16 sqmm ( colour coding RYB) will be measured as one length of 1 RM)
20S&Fin replacement of Water meter 100 mm nominal bore conforming to IS:2373-1981 having CI casing bronze body and SS/Alloy/Bronze gear having dial duly marked with litres or kilolitres in boldface, thread/flanged end type with provision of strainer out side the meter complete all as specified and as directed .
21S&F in replacement of Foot Valve conforming to IS-4038 flanged ISI marked completed with nut, bolts, washers etc including taking out old existing u/s foot valve of 100 mm dia.
22S&F Push Button 22.5 mm with push knob flush type having 1 NO & 1 NCilluminated type for putting on / off the starter.
23S&F LED indicating light surge and low voltage protected 220 / 240 Volts AC, Colour R/Y/G/A for LT Panels.
24S&F electronic star delta Timer ( 1 to100 sec) DQR 415/240V,110V : AC complete.
25Cutting down leaking piece of pipe 100mm. Cut down the rusted & leaking portion , providing(i) new piece of GI pipe 100 mm medium grade upto 0.50 metre long (ii) New union socket 100 mm - 1 Nos. (iii) Jointing the new pipe with existing old pipe by means of welding to make it leakproof including testing on completioncomplete all as specified anddirected."Note:- Unit rate quoted shall be included for (a) Necessary excavation/earth work (b) New GI pipe 100 mm upto 0.50 metre length (c ) union socket 100mm - 1 Nos. (d) welding etc complete including testing on completion.
26Cutting down leaking piece of pipe 80mm. Cut down the rusted & leaking portion , providing(i) new piece of GI pipe 80 mm medium grade upto 0.50 metre long (ii) New union socket 80 mm - 1 Nos. (iii) Jointing the new pipe with existing old pipe by means of welding to make it leakproof including testing on completioncomplete all as specified anddirected."Note:- Unit rate quoted shall be included for (a) Necessary excavation/earth work (b) New GI pipe 80 mm upto 0.50 metre length (c ) union socket 80mm - 1 Nos. (d) welding etc complete including testing on completion.
27Cutting down leaking piece of pipe 50mm. Cut down the rusted & leaking portion , providing(i) new piece of GI pipe 50 mm medium grade upto 0.50 metre long (ii) New union socket 50 mm - 1 Nos. (iii) Jointing the new pipe with existing old pipe by means of welding to make it leakproof including testing on completioncomplete all as specified anddirected."Note:- Unit rate quoted shall be included for (a) Necessary excavation/earth work (b) New GI pipe 50 mm upto 0.50 metre length (c ) union socket 50mm - 1 Nos. (d) welding etc complete including testing on completion.
28Cutting down leaking piece of pipe 40mm. Cut down the rusted & leaking portion , providing(i) new piece of GI pipe 40 mm medium grade upto 0.50 metre long (ii) New union socket 40 mm - 1 Nos. (iii) Jointing the new pipe with existing old pipe by means of welding to make it leakproof including testing on completioncomplete all as specified anddirected."Note:- Unit rate quoted shall be included for (a) Necessary excavation/earth work (b) New GI pipe 40 mm upto 0.50 metre length (c ) union socket 50mm - 1 Nos. (d) welding etc complete including testing on completion.
29Cutting down leaking piece of pipe 25mm. Cut down the rusted & leaking portion , providing(i) new piece of GI pipe 25 mm medium grade upto 0.50 metre long (ii) New union socket 25 mm - 1 Nos. (iii) Jointing the new pipe with existing old pipe by means of welding to make it leakproof including testing on completioncomplete all as specified anddirected."Note:- Unit rate quoted shall be included for (a) Necessary excavation/earth work (b) New GI pipe 25 mm upto 0.50 metre length (c ) union socket 50mm - 1 Nos. (d) welding etc complete including testing on completion.
30Cutting down leaking piece of pipe 20mm. Cut down the rusted & leaking portion , providing(i) new piece of GI pipe 20 mm medium grade upto 0.50 metre long (ii) New union socket 20 mm - 1 Nos. (iii) Jointing the new pipe with existing old pipe by means of welding to make it leakproof including testing on completioncomplete all as specified anddirected."Note:- Unit rate quoted shall be included for (a) Necessary excavation/earth work (b) New GI pipe 20 mm upto 0.50 metre length (c ) union socket 20mm - 1 Nos. (d) welding etc complete including testing on completion.
31Cleaning of RCC OH Tank of capacity 50000 Gln on staging 20 feet height throughly removing mud, grits etc. from the sump by following method:- (a) Removing all dirt,mud with the help of containers mannually from inside to the water storage Sump, then scraping to walls/pillars/floor complete as directed. (b) Washing with clean water after scraping with wire brush in side and removing mud and spoil to a distance n.exc. 50 mtrs.(c) Washing with clean water and bleaching powder including scraping wire brush on walls/pillars/floor removing mud, grits & deposits etc properly. (d) Repair/ Replacement to all inlet/out lets of sump with a reqd size of MS/GI Pipe as directed including cement work etc complete leakage proof.(MS/GI Pipe if reqd, it will be measured and paid separately).(e) Dry washed walls, coating with a one coat of white cement in side and out side two coat of white wash with lime the whole surface of walls/pillars and floor/roof of sump.
32Cleaning of RCC UG sump of capacity 100000 Glnon staging 20 feet height throughly removing mud, grits etc. from the sump by following method:- (a) Removing all dirt,mud with the help of containers mannually from inside to the water storage Sump, then scraping to walls/pillars/floor complete as directed. (b) Washing with clean water after scraping with wire brush in side and removing mud and spoil to a distance n.exc. 50 mtrs.(c) Washing with clean water and bleaching powder including scraping wire brush on walls/pillars/floor removing mud, grits & deposits etc properly. (d) Repair/ Replacement to all inlet/out lets of sump with a reqd size of MS/GI Pipe as directed including cement work etc complete leakage proof.(MS/GI Pipe if reqd, it will be measured and paid separately).(e) Dry washed walls, coating with a one coat of white cement in side and out side two coat of white wash with lime the whole surface of walls/pillars and floor/roof of sump.
33Cleaning of RCC UG sump of capacity 30000 Glnon staging 20 feet height throughly removing mud, grits etc. from the sump by following method:- (a) Removing all dirt,mud with the help of containers mannually from inside to the water storage Sump, then scraping to walls/pillars/floor complete as directed. (b) Washing with clean water after scraping with wire brush in side and removing mud and spoil to a distance n.exc. 50 mtrs.(c) Washing with clean water and bleaching powder including scraping wire brush on walls/pillars/floor removing mud, grits & deposits etc properly. (d) Repair/ Replacement to all inlet/out lets of sump with a reqd size of MS/GI Pipe as directed including cement work etc complete leakage proof.(MS/GI Pipe if reqd, it will be measured and paid separately).(e) Dry washed walls, coating with a one coat of white cement in side and out side two coat of white wash with lime the whole surface of walls/pillars and floor/roof of sump.
34Cleaning of RCC Semi UG sump of capacity 15000 Glnon staging 20 feet height throughly removing mud, grits etc. from the sump by following method:- (a) Removing all dirt,mud with the help of containers mannually from inside to the water storage Sump, then scraping to walls/pillars/floor complete as directed. (b) Washing with clean water after scraping with wire brush in side and removing mud and spoil to a distance n.exc. 50 mtrs.(c) Washing with clean water and bleaching powder including scraping wire brush on walls/pillars/floor removing mud, grits & deposits etc properly. (d) Repair/ Replacement to all inlet/out lets of sump with a reqd size of MS/GI Pipe as directed including cement work etc complete leakage proof.(MS/GI Pipe if reqd, it will be measured and paid separately).(e) Dry washed walls, coating with a one coat of white cement in side and out side two coat of white wash with lime the whole surface of walls/pillars and floor/roof of sump.
35Cleaning of RCC Semi UG sump of capacity 10000 Glnon staging 10 feet height throughly removing mud, grits etc. from the sump by following method:- (a) Removing all dirt,mud with the help of containers mannually from inside to the water storage Sump, then scraping to walls/pillars/floor complete as directed. (b) Washing with clean water after scraping with wire brush in side and removing mud and spoil to a distance n.exc. 50 mtrs.(c) Washing with clean water and bleaching powder including scraping wire brush on walls/pillars/floor removing mud, grits & deposits etc properly. (d) Repair/ Replacement to all inlet/out lets of sump with a reqd size of MS/GI Pipe as directed including cement work etc complete leakage proof.(MS/GI Pipe if reqd, it will be measured and paid separately).(e) Dry washed walls, coating with a one coat of white cement in side and out side two coat of white wash with lime the whole surface of walls/pillars and floor/roof of sump.
36Cleaning of RCC Semi UG sump of capacity 5000 Glnon staging 10 feet height throughly removing mud, grits etc. from the sump by following method:- (a) Removing all dirt,mud with the help of containers mannually from inside to the water storage Sump, then scraping to walls/pillars/floor complete as directed. (b) Washing with clean water after scraping with wire brush in side and removing mud and spoil to a distance n.exc. 50 mtrs.(c) Washing with clean water and bleaching powder including scraping wire brush on walls/pillars/floor removing mud, grits & deposits etc properly. (d) Repair/ Replacement to all inlet/out lets of sump with a reqd size of MS/GI Pipe as directed including cement work etc complete leakage proof.(MS/GI Pipe if reqd, it will be measured and paid separately).(e) Dry washed walls, coating with a one coat of white cement in side and out side two coat of white wash with lime the whole surface of walls/pillars and floor/roof of sump.
37S&F in repair/replacement of LT distribution control panel board of 2 mm thick CRCA sheet panel board of size 2100 x 1060 x 400 mmcomplete with fabrication, Indoor door type with internal wiring and control wiring incl Copper Bus Bar 940 Amp, 4 strip, 4 wire system on insulators, painting etc complete.(Sub Stn No-1). (a) (Incomer) MCCB 4 Pole, current rating 630 Amp, thermal setting adjustable 80%-100% breaking capacity 50kA at 415V,50Hz-01No. (b) (Out going) MCCB 4 Pole, current rating 250 Amp, thermal setting adjustable 70%-100% breaking capacity 36kA at 415V,50Hz-02Nos. (c) (Out going) MCCB 4 Pole, current rating 160 Amp, thermal setting adjustable 70%-100% breaking capacity 36kA at 415V,50Hz-01No. (d) S&F Isolator 4 Pole, 63 Amp, 415V, complete-02Nos. (e) Digital Volt meter 0 - 500V, size 96x96 mm square type with selector switch- 01 Set. (f) Digital Amp Meter 0 - 500 Amp, size 96x96 mm square type with selector switch - 01 Set. (g) Copper wound CTs with ratio 500/5 - 01 set. (h) Indicator Lamps LED type showing R,Y,B - 01 Set(Set of 3 ).
38S&F in repair/replacement of LT distribution control panel board of 2 mm thick CRCA sheet panel board of size 1800 x 1060 x 400 mmcomplete with fabrication, Indoor door type with internal wiring and control wiring incl Copper Bus Bar 515 Amp, 4 strip, 4 wire system on insulators, painting etc complete.(Sub Stn No-1) (a) (Incomer) MCCB 4 Pole, current rating 350 Amp, thermal setting adjustable 70%-100% breaking capacity 36kA at 415V,50Hz-01No. (b) (Out going) MCCB 4 Pole, current rating 200 Amp, thermal setting adjustable 70%-100% breaking capacity 36kA at 415V,50Hz-01No. (c) (Out going) MCCB 4 Pole, current rating 160 Amp, thermal setting adjustable 70%-100% breaking capacity 36kA at 415V,50Hz-01No. (d) S&F Isolator 4 Pole, 63 Amp, 415V, complete-02Nos. (e) Digital Volt meter 0 - 500V, size 96x96 mm square type with selector switch - 01 Set. (f) Digital Amp Meter 0 - 160/200/250/400 Amp, size 96x96 mm square type with selector switch - 01Set. (g) Copper wound CTs with ratio 400,250,200,160/5 - 01 set. (h) Indicator Lamps LED type showing R,Y,B - 01 Set(Set of 3 ).
39S&F in repair/replacement of LT distribution control panel board of 2 mm thick CRCA sheet panel board of size 1800 x 1060 x 400 mmcomplete with fabrication, Indoor door type with internal wiring and control wiring incl Copper Bus Bar 625 Amp, 4 strip, 4 wire system on insulators, painting etc complete.(Sub Stn No-2). (a) (Incomer) MCCB 4 Pole, current rating 400 Amp, thermal setting adjustable 70%-100% breaking capacity 36kA at 415V,50Hz-01No. (b) (Out going) MCCB 4 Pole, current rating 160 Amp, thermal setting adjustable 70%-100% breaking capacity 36kA at 415V,50Hz-03Nos. (c) S&F Isolator 4 Pole, 63 Amp, 415V, complete-02Nos. (d) Digital Volt meter 0 - 500V, size 96x96 mm square type with selector switch - 01 Set. (e) Digital Amp Meter 0 - 160/200/250/400 Amp, size 96x96 mm square type with selector switch - 01Set. (f) Copper wound CTs with ratio 400,250,200,160/5 - 01 set. (g) Indicator Lamps LED type showing R,Y,B - 01 Set(Set of 3 ).
40S&F Cost of 16 SWG sheetof LT distribution control panel board (for 15 HP Pump) of size 2100 x 1260 x 600 mmcomplete with fabrication, Indoor door type with internal wiring and control wiring incl Copper Bus Bar 145 Amp, 4 strip, 4 wire system on insulators, painting etc complete.(Pump House Solan) . (a) (Incomer) MCCB 4 Pole, current rating 100 Amp, thermal setting adjustable 70%-100% breaking capacity 36kA at 415V,50Hz-01No. (b) (Out going) MCCB 3 Pole, current rating 63 Amp, thermal setting adjustable 70%-100% breaking capacity 36kA at 415V,50Hz-02Nos. (c) Starter FASD-2 Nos. for centrifugal pumps. (d) Ammeter digital type 96 mm Square 2. (e) Voltmeter digital type 96 mm Square. (f) Selecter switch 3 ON & OFF-3 Nos. (g) Indicator lamps 7 Star 7 Nos. (h) CTs Copper wound -6 Nos. (j) Automation system-2 Nos.
41Taking out existing earthings and M&L for replacement of chemical earthing (Pipe in pipe technology) Two B class IS mild steel pipe, one inside the other, hot dip galvanised with 100 micron coating outside and about 300 micron coating inside filled with high conductive and corrosion Resistant Crystalline Mixture inside and Backfill compound around the outer electrode) outer electrode dia 72 to 80mm and inner electrode dia 35 to 40 mm both 10" long, incldg making earth pit of size 4" x 4" and 11" deep fill the entire pit with black cotton soil or normal soil, pour enough water so that pit is full with water, leave it for three days so that soil soaks up the water, the soil level has goes down, again top up the pit with soil & fill the water.After two or three days when the pit is sturdy and ready for earthing purpose, install the earthing electrode as per installation method as below:-(a) Mix backfill compound evenly with soil.(b) Remove plastic sleeve carefully from electrode.(c) Place naked electrode at centre of pit.(d) Start refilling empty space around electrode with backfill compound in layers. (e) Pour some water and poke the pit with a long wooden rod to allow trapped air to escape.(f) Gradually continue refilling process till electrode is buried in the pit up to the green patch painted on the top portion of electrode.(g)Ensure that pit is not watery (h) Pack electrode with compound nicely and tightly, so that it stands firmly in pit.(j)Pour a few buckets of water around pit.(k)Pour a few buckets of water around in the pit everday for 10-15 days for system to set.(l)Connect the earth electrode with equipments by 25mm x 3mm aluminium strip.(m)Earthing test point terminal block made of gun metal size 150x100x50 mm drilled and screwed including 4 Nos 8 mm dia 40 mm long hexagonal head bolts and washers duly fixed on walls with fasteners 4 Nos. Note : (a) Earth resistance shall not be more than 5 Ohm.(b) Aluminium strip for connections shall be measured and paid separately.
42Taking out existing earthings and M&L for replacement of "Earthing complete withand including galvanised steel earth plate electrode 60 cmx 60cm x 6 mm thick surrounded by mixtureof charcoal and salt in alternate layers ,buried directly in ground vertically in a pit of depth not less than 2.25 meter deep below ground level with top as of the plate at a depth of not less than 1.5 mtrs below normal ground level connected to equipment by using GI strips of size 32x6 mm as earthing lead by means of bolts ,nuts, check nuts and washers of galvanised iron or steel earth wire protected by galvanised steel pipe 15 mm bore (light grade)and 20mm bore "Light" grade GI watering pipe connected to main switch or main control boardor GOD or lightening arrester all as shown in electrical plate No. 3of SSR - 2009(Pt I) & including necessary excavation and earth work. The rate also include charcoal and salt in alternate layers, 20 mm bore GI pipe (Light grade ) for watering , protection pipe funnel, wire mesh , PCC 1:2:4 type B1 chamber in cement concrete ,50 mm thick precast RCC M-25 ( Design mix) cover duly reinforced with XPM (weight not less than 3 kg /sqm ) and CI frame etc , and including provision of test point , connecting to test point and testing on completion etc, complete all as specified. NOTE : The unit rate include earthing lead and protection pipe upto 7.5 metre from top of earth plate.
43Supply & fixing Glavanised iron strip 32x6mm buried in ground.
44Earthing with Galvanised iron earth plate electrode 600mm x 600 mm & 6 mm thick burried directly in ground (earth pit not less than 2.25 metre deep below normal GL) with top of earth plate not less than 1.5 metre below GL, connected to GI earth lead wire 4 mm dia connected to earth plate electrode by means of GI nuts, bolts & washers earth wire protected with & including 15 mm bore medium grade ISI marked GI pipenot less than 7.5 metre long all as shown in electrical plate No 3 of MES Schedule Part I, with & including; PCC 1:3:6 type C1 pit with cover of RCC 1:2:4 typeB1 reinforced with welded steel wire fabric not less than 4 Kg per Sq M, watering arrangements with 20 mm bore GI medium grade pipe ISI marked , GI funnel with GI mesh, filling with mixture of common salt & charcoal, necessary excavation and earth works in any type of soil, including test point, testing & commissioning, complete.
45S&F glow shine board size 18’x3’ made out of 24 gauge GI sheet and front with acrylic sheet total enclosed with computerised letter writings of size not less than 100mm as decided by Engineer-in-Charge and inside with 4’ long 02 Nos of 36w tube light fitting complete with time control switch, MCB and battery back up with timer and synchronised motor board including wiring should be fix on 40mm bore medium grade pipe.The height of board from ground level is 7’ (upto top) and the bottom of the board is 4’.The pole embedded in PCC 1:2:4 type B-1 using 20mm graded agg of size 450x450x600mm with complete service connection of 2.50 Sqmm 3 core copper sheathed cable 10 metre long including protection pipe service connection from the pole by means of 25mm dia light grade pipe to the boardincluding excavation, returning filling and removing out surplus soil all as specified and as directed by Engineer-in-Charge.
46Taking out old unsv and Supplying, fixing and testing of cast steel Sluice valve PN1.6 as per IS-14846, body, dome, wedge-CI IS:210, rings-bronze IS:318, Spindal-SS IS:6603, Gland Paking greasy jute packing, fasteners-CS, Gasket- Natural rubber, nominal size DN-150 mm, both ends flanged in existing line,afterremoval of old unserviceablesluice valve without damagingtoexistingpipeline complete all as specified and directed by Engr-in-charge. Note : Suitable size flanges for existing pipe line, Joints and jointing materials shall be included under this item.
47All as per serialitem No. 25 here-in-before but nominal size DN-100 mm-ditto-.
48All as per serialitem No. 25 here-in-before but nominal size DN-80 mm-ditto-.
49S&F Cast iron Non Return valve W/O by pass arangement , Swing type, of Size 100 mm bore, confirming to IS 5312, flanged ends with nuts bolts, washers complete including taking down of old one .
50S&F Cast iron Non Return valve W/O by pass arangement , Swing type, of Size 150 mm bore, confirming to IS 5312, flanged ends with nuts bolts, washers complete including taking down of old one .
51Supply and fix Cast Iron Air Release Valves with two air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains of size 100 mm dia.
52Supply and fix Cast Iron Air Release Valves with two air Outlets, conforming to IS 14845 of size 150 mm dia bore and fixing up in Cast Iron Water supply mains of size 150 mm dia.
53Construction ofbrick masonary pit of size 60 x 60 x 60cm internal size with MS sheet 3mm thick and angle iron frame of size 40x40x6mm duly paintedwith 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and shown in drawingNo. STD- 1258, sheet 1/1. (original date - 30.11.93 and revised date - 15.09.2000 ) Note : Drawing mentioned above has not been enclosed herewith, however the same can be seen in the office ofGE Kasauli.
54Construction ofbrick masonary pit of size 90 x 90 x 90 cm internal size with MS sheet 3mm thick and angle iron frame of size 40x40x6mm duly paintedwith 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and shown in drawingNo. STD- 1258, sheet 1/1 (original date - 30.11.93 and revised date - 15.09.2000 ) Note : Drawing mentioned above has not been enclosed herewith, however the same can be seen in the office ofGE Kasauli.
55Construction ofbrick masonary pit of size 120 x 120 x 120 cm internal size with MS sheet 3 mm thick and angle iron frame of size 40x40x6mm duly paintedwith 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and shown in drawingNo. STD- 1258, sheet 1/1 (original date - 30.11.93 and revised date - 15.09.2000 ) Note : Drawing mentioned above has not been enclosed herewith, however the same can be seen in the office ofGE Kasauli.
56Supply of calcium hypo chloride, 65%-70% chlorine content, high strength granular disinfectant for treatment of drinking water complete all as specified and qty as per requirement and as directed by Engr-in-Charge.
57S&F in replacement of Bronze gate valve for 15mm bore pipe,with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, fixed as in repair complete all as specified and directed.
58All as per serialitem No. 47.00 here-in-before but of size 20mm bore-ditto-.
59All as per serialitem No. 47.00 here-in-before but of size 25mm bore-ditto-.
60All as per serialitem No. 47.00 here-in-before but of size 40mm bore-ditto-.
61All as per serialitem No. 47.00 here-in-before but of size 50mm bore-ditto-.
62Taking out unserviceable/defective/damaged/blockage GI/MS pipe 40 mm bore steel water tubing,sorting out serviceable pipe fitting for reuse and cleaning the pipe including fitting and removing away all unserviceable pipe from site, complete all as specified and as directed. (Note: Exacavation and earhwork shall be measured and paid for separately).
63All as per serialitem No. 52.00 here-in-before but of size 50mm bore-ditto-.
64All as per serialitem No. 52.00 here-in-before but of size 80mm bore-ditto-.
65All as per serialitem No. 52.00 here-in-before but of size 100mm bore-ditto-.
66S&F steel watertubing medium grade, ISI Marked conforming to IS 1239 Part-I 2004, 40mm bore with and including all fittings such as bends , elbows,tees, short length , socket, union, check nuts, nipples and weldings etc. fixed and laid in trenches/floor/under culvert/road crossing etc including testing complete all as specified and as directed.
67All as per serialitem No. 56.00 here-in-before but of size 50mm bore-ditto-.
68All as per serialitem No. 56.00 here-in-before but of size 80mm bore-ditto-.
69All as per serialitem No. 56.00 here-in-before but of size 100mm bore-ditto-.
70Amount of credit of Rs. 63808.60 for retrived old material as mentioned in Schedule "A" section-II of tender document in pdf form, will be deducted offline while acceptence of tender.
Disclaimer :