Construction Of Dedicated Water Pipe Line From Rushikulya River To Gopalpur Military Station Under Ge I Gos , gopalpur-Odisha

Military Engineer Services-MES has published Construction Of Dedicated Water Pipe Line From Rushikulya River To Gopalpur Military Station Under Ge I Gos . Submission Date for this Tender is 01-08-2022. Water Pipe Line Tenders in gopalpur Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

33158967
Construction Of Dedicated Water Pipe Line From Rushikulya River To Gopalpur Military Station Under Ge I Gos
Open Tender
Indian
Odisha
gopalpur
01-08-2022

Tender Details

Construction Of Dedicated Water Pipe Line From Rushikulya River To Gopalpur Military Station Under Ge I Gos

Key Value

Document Fees
INR 500 /-
EMD
INR 84000.0 /-
Tender Value
INR 42 Lakhs /-

BOQ Items

Name of Work: CONSTRUCTION OF DEDICATED WATER PIPE LINE FROM RSHIKULYA RIVER TO GOPALPUR MILITARY STATION UNDER GE (I) GOS
Sl. No. Item Description
1Excavation in trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable/Pole/Stays etc getting out in Soft/Loose Soil complete all as specified and directed.
2Excavation in trenches, not exc. 1.50 Metre wide and exc. 1.50 Metre depth but not exc. 3.00 Metre in depth, for Foundation of Poles/ Stays, etc. and getting out in Soft/ Loose Soil, complete all as specified and directed.
3Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and directed.
4Removing Surplus soil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and directed.
5M & L clean dry river sandin trenches/ducts for cushioning to cable, 8 cm in depth before laying the cable and 15 cm in depth after laying the cable complete all as specified and directed. Note : Punned thick ness of sand shall be measyred and paid.
6M & L Cement Concrete PCC 1:4:8 (using 40 mm graded stone aggregate), type D2 as concrete in foundation of Poles andfilling and mass concrete etc, including formwork (as if required), complete all as specified and directed.
7M & L Cement Concrete PCC 1:3:6 (using 20 mm graded stone aggregate) type C2 as concrete in foundation of Poles andfilling and mass concrete etc, including formwork (as if required), complete all as specified and directed.
8M & L Cement Concrete PCC 1:2:4 (using 20 mm graded stone aggregate) type B2 as in coping of pole, for staysetc including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified and directed.
9M&L for prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and l2mm x 279mm at bottom,class 10 complete all as specified and directed.
10Supplying and laying unreinforced precast cement concrete cable covers, Class LV, Type- 1, Flat, size 250 mm x 150 mm x 40 mm in trenches for cable protection, embossed with "LT 1100 VOLTSELECTRIC" on the top surface complete all as specified and directed.
11Supply and fixing GI Pipe light grade with all fittings for passing of cables fixed to pole / wall / laid under floor or roads including all fixing accessories complete for protection of cable of following sizescomplete all as specified and directed. (a) 100 mm bore
12(b) 80 mm bore
13(c) 50 MM bore
14S & F Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 (using 20 mm graded stone aggregrate ) of size 900 x 300x 100 mm thick with DANGER / 440 VOLTS, LT CABLE /MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work ( as required / ordered at site) complete all as specified and directed.
15M & L forRS Joist pole galvanized of size150 mm x150 mm of 12 meter long with MS base plate 6mm thick and of size 300 x 300 welded to bottom of pole, fixing of cross arms, black & yellow colour at lower portion of exposed pole starting from plinth blockband of 1200 mm height (4 Nos each Strip of 150 mm width), painting pole No by the black paint by stenciled letters/ figures of 8 cm height complete all as specified and directed. Note:-Earthwork, Cement Concrete, cross arms etc. will be measured and paid under approprite Items.
16S & F pin type, polymer/ percelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 Volts grade complete all as specified and directed.
17S & F Disc type insulator, polymer/porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green, two in series for tension with tension clamps for conductors assembly, working pressure 11000 volts complete all as specified and directed. .
18S & F Aluminium Conductor Steel Reinforced (ACSR) (sizes as ordered) with permissible Sags and providing Jumper etc, fixing on 12 Mtr Electric Poles and binding to Insulators with Aluminium Binding Wire as in OH Conductors including stringing, tightening etc, complete all as specified and directed. Note: Cost of Binding Wire is deemed to be included in the quoted Unit Rate.
19M & L for galvanised steel wire 3.15 to 4 mm dia to be stringed as guarding to road crossing under theover head HT lines complete all as specified and directed.
20S & F for Anti climbing spikes type fabricated out of MS flat of 50mm x 6mm in two parts with 14 Nos 230 mm long 12 mm dia spikes sharpened edge and including nut,bolts & washers and welding made to shape to suit the cross section of pole including two coat of first grade aluminium paint over a coat of red oxide primer complete all as specified and directed.
21S & F for Galvanized Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed complete all as specified and directed.
22M & L Stay Assembly complete with Accessories as show in Electrical Plate No. 1 of MES Schedule Part-I, diameter of Stay Rod 20 mm, size of Plate 230 x 230 x 6 mm complete all as specified and directed. Note: Earthwork, Cement Concrete, Mild Steel Stay Clamps with Bolts, Nuts, Stay Strand, Loop Insulator etc. will be measured and paid under approprite Items.
23M&L stay stand of size 7/4.0 mm to keep the pole in true vertical position complete all as specified and directed.
24S & F Loop Type Insulator Vitreous White, Brown or Green, large size with overall dimensions 90 mm x140 mm, clearance of hole 25.50 mm dia, complete all as specified and directed.
25M & L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25 x 20 cm size complete all as specified and directed.
26Supply,laying,testing and commissionnig of UG HT cables, 11000 volts grade, 3 core x 95 sqmm (Earthed), XLPE insulated and PVC shealhed, steel wire armoured, with multi stranded aluminum conductor, heavy duty conforming to latest relevant IS, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete all as specified and directed.
27Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes complete all as specified and as directed. (a) 3.5 core x 300 Sqmm (from transformer to Main LT Panel)
28(b) 3.5 core x 240 Sqmm (from Main LT Panel to Pump house Panel)
29(c) 3.5 core x 120 Sqmm (from Main LT Panel to APFC Panel)
30(d) 3.5 core x 70 Sqmm (from transformer to main LT Panel)
31(e) 3.5 core x 50 Sqmm (from main LT panel to pump house panel & APFC panel)
32S&F cable jointing kit for 11 kV grade cable for outdoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE (E) armoured, aluminium conductor cable of size 95 sq mm complete all as specified and directed.
33Supplying, installing, fixing, commissioning and testing of Air break gang operated triple pole switch out door type of capacity 200 Amps AC mechanically operated mounted on polymer based insulators and steel frame with operating mechanism worked from ground levelcomplete withlocking arrangements incl pad locks with key complete suitable for 11KV, HT, 50 Hz complete all as specified and directed.
34Supplying, installing, fixing, commissioning and testing of polymer based Drop-out fuse set (set of 3 nos) 200 Amp AC, mounted on insulatorswith steel frame with Expulsion fuse carriers and fuse element Upto 25 Amp complete suitable for 11KV, HT, 50 Hz complete all as specified and directed.
35S&FLightening arrestor HT 11 KV, non linear resistor typeconforming to IS 3070 (part-1) 1993 complete, line discharge class-3, nominal discharge current 65 KA (peak), 12 KV rated system, voltage peak value high current implus of 4/10 micro Sec wave shape 100 KA (peak) assembly suitable for 11 KV, longduration descharge class-II with insulation level 28/ 75 KV and mounted on hot dip galvanized steel structure including all clamps, nuts, bolts and washers and connecting to earth with 4 mm dia GIwire complete all as specified and directed.
36Supply, install, test and commissioning step down transformer, outdoor type, and conforming to IS 1180:2014, level -3, plinth mounted, HT 11 KV, 3 phase 433 volts, 4 wire, 50 Hz, delta/ starconnected, vector group DYN -11 double copper wound, ONAN, manual type off load tap changing facility on HT side to vary secondary voltage from minus 7.5% to plus 7.5% in steps of 2.5 %, continuous rating of capacity 250 KVA including bushing on HT end cable box on LT side. The Transformer shall be complete with all standard fittings and accessories, gauges, first fill of transformer oil IS 335 ISI marked filtered & dehydrated oil etc, complete all as specified and directed and comprising of the following accessories :- Note:- Transfomer shall be mounted on platform/plinth. (a) Primary HV side suitable for OH conductor(consisting of 3 Nos porcelain HT bushings with brass/gun metal bushing rods complete with nuts and washers). (b) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushing with GM bushing rods complete with GM nuts, and washers with one No cable gland suitable for reception of outgoing LT armoured cables of suitable size. (c) Oil conservator tank with filter type, drain valve and oil level gauge. (d) Dehydrating breather with first fill of dehydrating agent. (e) Thermometer pocket on tank cover. (f) One No 100mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting device. (g) Rating plate with terminal markings. (h) Two earthing terminals on tank/tank cover to facilitate fixing of 32x6m GI eath strip. (j) Oil Level gauge. (k) Oil drain and filter valves. (l) Oil filler hole with cap/plug with connections complete. (m) Lifting lugs.
37(n) Air relief valve plug. (o) Four plan solid cast steel detachable rollers. (p) First fill of fresh oil conformingto relvant IS and tested upto 50 KV dielectric strength upto top of core. (q) Extra bushing for neutal outside the LT cable box for providing independent earthing for neutral. (r) Provision of 2 Nos danger boards 250 x 200mm size made out of 1.6 mm thick MS plate, vitreous enameled white, with letters, figures of vltage and conventional skull and bones in signal red colour, one at HT side and other on LT side. (s) Any other fittings/accessories so as to confirm the whole transformer to IS-1180 Part-I:2014. (t) Construction of Plinth of size 2.0mx 2.0mx1.5m for transformer, using 100 mm thick PCC 1:4:8 type D-2 as in lean concrete, flyash brick masonry in CM 1:6, the top of the plinth shall consist of 100 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregates) over 75 mm thick PCC 1:4:8 type D-2 over compacted moorum filling, 10 mm thick rendering in CM 1:4 on brick surface with and including 25 cm thick stone aggregates of size 12.5 mm all around upto and including 1.5 m from the edge of the plinth including the RCC Gate and fencing with angle iron post in lieu of RCC post complete all as specified and directed.
38Supply, install, test and commissioning step down transformer, outdoor type, and conforming to IS 1180:2014, level -3, plinth mounted, HT 11 KV, 3 phase 433 volts, 4 wire, 50 Hz, delta/ starconnected, vector group DYN -11 double copper wound, ONAN, manual type off load tap changing facility on HT side to vary secondary voltage from minus 7.5% to plus 7.5% in steps of 2.5 %, continuous rating of capacity 100 KVA including bushing on HT end cable box on LT side. The Transformer shall be complete with all standard fittings and accessories, gauges, first fill of transformer oil IS 335 ISI marked filtered & dehydrated oil etc, complete all as specified and directed and comprising of the following accessories :- Note:- Transfomer shall be mounted on platform/plinth. (a) Primary HV side suitable for OH conductor(consisting of 3 Nos porcelain HT bushings with brass/gun metal bushing rods complete with nuts and washers). (b) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushing with GM bushing rods complete with GM nuts, and washers with one No cable gland suitable for reception of outgoing LT armoured cables of suitable size. (c) Oil conservator tank with filter type, drain valve and oil level gauge. (d) Dehydrating breather with first fill of dehydrating agent. (e) Thermometer pocket on tank cover. (f) One No 100mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting device. (g) Rating plate with terminal markings. (h) Two earthing terminals on tank/tank cover to facilitate fixing of 32x6m GI eath strip. (j) Oil Level gauge. (k) Oil drain and filter valves. (l) Oil filler hole with cap/plug with connections complete. (m) Lifting lugs.
39(n) Air relief valve plug. (o) Four plan solid cast steel detachable rollers. (p) First fill of fresh oil conformingto relvant IS and tested upto 50 KV dielectric strength upto top of core. (q) Extra bushing for neutal outside the LT cable box for providing independent earthing for neutral. (r) Provision of 2 Nos danger boards 250 x 200mm size made out of 1.6 mm thick MS plate, vitreous enameled white, with letters, figures of vltage and conventional skull and bones in signal red colour, one at HT side and other on LT side. (s) Any other fittings/accessories so as to confirm the whole transformer to IS-1180 Part-I:2014. (t) Construction of Plinth of size 2.0mx 2.0mx1.5m for transformer, using 100 mm thick PCC 1:4:8 type D-2 as in lean concrete, flyash brick masonry in CM 1:6, the top of the plinth shall consist of 100 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregates) over 75 mm thick PCC 1:4:8 type D-2 over compacted moorum filling, 10 mm thick rendering in CM 1:4 on brick surface with and including 25 cm thick stone aggregates of size 12.5 mm all around upto and including 1.5 m from the edge of the plinth including the RCC Gate and fencing with angle iron post in lieu of RCC post complete all as specified, directed by the Engineer-in-charge and as shown on TD drawing No CEPZ/98/TD/6, Sheet No 2/2.
40Supply and install automatic power factor correction (APFC) panel outdoor type factory made of capacity 100 KVAR ready to use design confiring to relevantIS rated for short circuit rating of 50 KA, front openable and lockable by keys having lowers and air vent, gasket and totally vermin proof and suitable for 415/ 440 Voils, 3 phase 50 Hz, AC and housed in elegant enclosure fabricated from minimum 3.00 mm thick CRCA sheet, anti corrosive coating to achieve power factor from 0.9 to 0.99 and finally powder coated in texture seimens gray RAL 7032 & as directed by Engineer-in-Charge comprising of and includingfollowing including suitable size and lengthof copper conductor cable from main panel to APFC panel for connections as approved complete all as specified and directed:- (a) 320 Amp capacity for pahse and neutralCopper bus bar duly insulated with colour coaded heat shrinkable sleeves and mounted on suitable DMC/epoxy insulators. (b) A set of heavy duty capacitor type MPPH box type, 440 volts.with output steps of 100 KVAR capacity capacitor bank in steps of with 4 steps (1 x 50 KVAR + 1 x 25 KVAR + 1 x 15 KVAR + 1 x 10 KVAR) in any configuration to accommodate all possible set ups. (c)MCB"s TP, "C" series,415 volts, off sizes with required numbers and suitable ratings as per the capacity of capacitors . (d) Thyristor switches shall be provided bor connecting/disconnecting the capacitor banks to the bus bar. (e) The APFC panel provided with two existing terminal and it is connected through GI strip 32 x 6mm size complete all as specified and directed. (f)Micro processr based control suitable for power factor correction with its unique features of four quadrant operation automatic C/K ratio selection.The APFC controller should ON/OFF the capacitor banksof 100 KVAR capacity capacitor bank in 4 steps above configuration to accommodate all possible set ups with indication whether it is lagging or leading.
41(g) Digital panel meter for current,voltage/ frequency and power factor having programmable CT ratio and built in selector switch of size 96mmx96mm,accuracy class-I, auxiliary support of 230 volts AC with SP MCBprotected shall be provided. (h) All control wires shall be not less than 2.5 sqmm multistranded copper conductor and propeperly bunched/ tied,ferruled for proper identification and crimpled with adequate size of lugs. the cubicle will have a bottom support of channel of suitablesize, duly coated with zinc metal coating. A detachable pre drilled gland plate of thickness 2.00 mm thick, cold zink metal coated shall be provided with at the bottom for entry for armoured cable with adequate size of gland. Manufacturer name plate with feeder details and danger plate shall be provided at suitable visible place. (k) Auxiliary contactor with required quantity of "NO & NC" (l) Auto/ Manual switch-01 No. (m) Fuse for line protection as per requirement and as approved (n)Indicator lamp LED based with lamp holderas per requirement and as approved (p)Current transformer (CT) of ratio 250/5 A ,measuring class accuracy 0.50 to 1.0 for capacitor panel. (q) MCCB 4 Pole 200 Amps, thermal magnetic type breaking capacity 50 KA with microprocessor release with 4 step overload adjustability at 415 volts - 01 No (in coming) (r) Detuning reactor of suitable size shall be provided to maintain THD less than 7 percent.
42Supply and install automatic power factor correction (APFC) panel outdoor type factory made of capacity 40 KVAR ready to use design confiring to relevantIS rated for short circuit rating of 50 KA, front openable and lockable by keys having lowers and air vent, gasket and totally vermin proof and suitable for 415/ 440 Voils, 3 phase 50 Hz, AC and housed in elegant enclosure fabricated from minimum 3.00 mm thick CRCA sheet, anti corrosive coating to achieve power factor from 0.9 to 0.99 and finally powder coated in texture seimens gray RAL 7032 & as directed by Engineer-in-Charge comprising of and includingfollowing including suitable size and lengthof copper conductor cable from main panel to APFC panel for connections as approved complete all as specified and directed:- (a) 200 Amp capacity for pahse and neutralCopper bus bar duly insulated with colour coaded heat shrinkable sleeves and mounted on suitable DMC/epoxy insulators. (b) A set of heavy duty capacitor type MPPH box type, 440 volts.with output steps of 40 KVAR capacity capacitor bank in steps of with 3 steps (1 x 25 KVAR + 1 x 10 KVAR + 1 x 5 KVAR) in any configuration to accommodate all possible set ups. (c)MCB"s TP, "C" series,415 volts, off sizes with required numbers and suitable ratings as per the capacity of capacitors . (d) Thyristor switches shall be provided bor connecting/disconnecting the capacitor banks to the bus bar. (e) The APFC panel provided with two existing terminal and it is connected through GI strip 32 x 6mm size complete all as specified and directed. (f)Micro processr based control suitable for power factor correction with its unique features of four quadrant operation automatic C/K ratio selection.The APFC controller should ON/OFF the capacitor banksof 100 KVAR capacity capacitor bank in 8 steps above configuration to accommodate all possible set ups with indication whether it is lagging or leading.
43(g) Digital panel meter for current,voltage/ frequency and power factor having programmable CT ratio and built in selector switch of size 96mmx96mm,accuracy class-I, auxiliary support of 230 volts AC with SP MCBprotected shall be provided. (h) All control wires shall be not less than 2.5 sqmm multistranded copper conductor and propeperly bunched/ tied,ferruled for proper identification and crimpled with adequate size of lugs. the cubicle will have a bottom support of channel of suitablesize, duly coated with zinc metal coating. A detachable pre drilled gland plate of thickness 2.00 mm thick, cold zink metal coated shall be provided with at the bottom for entry for armoured cable with adequate size of gland. Manufacturer name plate with feeder details and danger plate shall be provided at suitable visible place. (k) Auxiliary contactor with required quantity of "NO & NC" (l) Auto/ Manual switch-01 No. (m) Fuse for line protection as per requirement and as approved (n)Indicator lamp LED based with lamp holderas per requirement and as approved (p)Current transformer (CT) of ratio 250/5 A ,measuring class accuracy 0.50 to 1.0 for capacitor panel. (q) MCCB 4 Pole 100 Amps, thermal magnetic type breaking capacity 50 KA with microprocessor release with 3 step overload adjustability at 415 volts - 01 No (in coming) (r) Detuning reactor of suitable size shall be provided to maintain THD less than 7 percent.
44Supply ,fabrication, installation and testing of LT Panel out door type factory made CPRI Approved, water and vermin proof protection of size 1000mm x 800mm x 500 mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incommingcableinclusive of necessary excavation and earthwork as required including the following fitment accessories all complete as specified and as directed. Note : Rate of earthwork and PCC work are deemed to be inclusive in this item. (a)Copper strip busbar of 800 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos (b)MCCB, Microprocessorrelease type, 4 poles, 415 Volts,Ics = 100% Icu, breaking capacity 35 KA , rating400 Amps including all fixing accessories with both ends spreader links - 01 No. (c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts,AC -01 set (set of three)Make :- Legrand/L&T/Schneider. (d)Digital Ammeter of range (0- 630) Amps, flush mounting type of size 100mm x 100mm (4”x4”) square dial with CT’s of ratio 250/5 and selector switch – 01 set (e)Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 No.
45OUTGOING: (a)MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity, rating 315 Amps including all fixing accessories with both ends spreader links-01 No (for Pump house panel) (b)MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity, rating 160 Amps including all fixing accessories with both ends spreader links-01 No(for APFC panel) (c)MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity, rating 63 Amps including all fixing accessories with both ends spreader links-01 No (for spare) (d)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.
46Supply ,fabrication, installation and testing of LT Panel out door type factory made CPRI Approved, water and vermin proof protection of size 1000mm x 800mm x 500 mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incommingcableinclusive of necessary excavation and earthwork as required including the following fitment accessories all complete as specified and as directed. Note : Rate of earthwork and PCC work are deemed to be inclusive in this item. (a)Copper strip busbar of 300 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos (b)MCCB, Microprocessorrelease type, 4 poles, 415 Volts,Ics = 100% Icu, breaking capacity 35 KA , rating160 Amps including all fixing accessories with both ends spreader links - 01 No. (c) On load change over Switch TPN of capacity 125 Amps - 01 No (d)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts,AC -01 set (set of three)Make :- Legrand/L&T/Schneider. (e)Digital Ammeter of range (0- 160) Amps, flush mounting type with CT’s of ratio 160/5 and selector switch – 01 set. (f)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No.
47OUTGOING: (a)MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity, rating 100 Amps including all fixing accessories with both ends spreader links-01 No (for Pump house panel) . (b)MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity, rating 63 Amps including all fixing accessories with both ends spreader links-02 No(for APFC panel & spare) (d)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.
48M&L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron strip of size 32 x 6 mm as earthing lead by mean of nut/bolt and washer of galvanized iron or steel drawn through 40 mm dia light grade GI pipe as shown in electrical plate no 3 of SSR part I of 2009 including necessary excavation and earth work GI pipe 20mm dia medium grade for wateringPCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to panel board/Gen Set as indicated including testing complete all as specified and directed. Note:- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
49M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 x 3 mm galvanised iron strip complete all as specified and directed.
50Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep, getting out watering and removing surplus soil to a distance n.exc 50m and making good surface complete all as specified and directed.
51M & L for loose filling withaggregate of size 40 mm graded of 20 cm thickness around at 2 pole HT structure complete all as specified and directed.
52M& L for Brickwork with straight or curved on plan with subclass ‘B’ bricks,exc 6 m mean radius built in CM 1:6 complete all as specified and directed.
53M & L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement water proofing compound complete all as specified and directed.
54Excavation in post holes (or similar holes) each not exc. 0.50 cum, getting out, returning, filling in and rammingearth orbroken rubble mixed with earth around in layers not exc. 25 cm, watering and removing surplus soil to a distance not exc. 50 metre and making good surfaces in soft / loose soil, complete all as specified and directed.
55M&L forplain Cement Concrete 1:3:6, Type C-2 of grade using 40mm graded stone aggregate in foundations, filling and mass concrete, etc. for embeddingfencing posts, complete all as specified and directed.
56Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wire complete all as specified and directed.
57Supply only for Chain link MS galvanisd fencing, any size or type complete all as specified and directed.
58M& L for Mild steel gate with framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work, portions framed and hung gates, including pintle hinges, stops, hand-made sliding bolts etc as conforming to Fe.290, Gde-E-165 complete all as specified and directed.
59M&L for preparation of new steel surfaces of any description over 10 cm width or girth not other wise described and applying two coats of synthatic enamel paint over one coat of red oxide primer complete all as specified and directed.
60Supply and providing sand cushioning with dry clean sand of 5 cm below the paver block complete all as specified and directed.
61M&L for machine pressed precast concrete interlocking paver block ISI marked, any shape and size of 60 mm thickness, M-35 Grade laid with grey cement &pigment complete all as specified and directed.
62M&L for PCC1:2:4, type B1 using 20 mm graded stone aggaregate in kerbs/ coping/ bed plates and like including weathering slightly rounded or chamfered completewith necessary use and waste to formwork complete all as specified and directed.
63M&L for 100 mm thick PCC1:4:8, type D2 using 40 mm graded stone aggaregate as in subbase complete all as specified and directed.