Comprehensive Maintenance Of Central Ac Plant 3 X 37.5 Tr Located At Dcn Palam And Repair And Maintenance Of Summer Appliances Including Desert Cooler And Water Cooler At Dcn Palam Under Ge ( U ) P And M Delhi Cantt-10, delhi-Delhi

Military Engineer Services-MES has published Comprehensive Maintenance Of Central Ac Plant 3 X 37.5 Tr Located At Dcn Palam And Repair And Maintenance Of Summer Appliances Including Desert Cooler And Water Cooler At Dcn Palam Under Ge ( U ) P And M Delhi Cantt-10. Submission Date for this Tender is 15-08-2022. Air Conditioner Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

33148471
Corrigendum : Comprehensive Maintenance Of Central Ac Plant 3 X 37.5 Tr Located At Dcn Palam And Repair And Maintenance Of Summer Appliances Including Desert Cooler And Water Cooler At Dcn Palam Under Ge ( U ) P And M Delhi Cantt-10
Open Tender
Indian
Delhi
delhi
15-08-2022

Tender Details

Comprehensive Maintenance Of Central Ac Plant 3 X 37.5 Tr Located At Dcn Palam And Repair And Maintenance Of Summer Appliances Including Desert Cooler And Water Cooler At Dcn Palam Under Ge ( U ) P And M Delhi Cantt-10

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Jul-2022 Corrigendum No 1 BOQ 08-08-2022
2 08-Aug-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-08-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 28040.0 /-
Tender Value
INR 14.02 Lakhs /-

BOQ Items

Name of Work: CCOMPREHENSIVE MAINTENANCE OF CENTRAL AC PLANT 3 X 37.5 TR LOCATED AT DCN PALAM AND REPAIR AND MAINTENANCE OF SUMMER APPLIANCES INCLUDING DESERT COOLER AND WATER COOLER AT DCN PALAM UNDER GE (U) P&M DELHI CANTT-10
Sl. No. Item Description
1Periodical, preventive and comprehensive maintenance of Central Air conditioning plant of capacity 3 x 37.5 TR as per manufactures manual of preventives and comprehensive maintenance and with periodicity mentioned there in as per particular specification installed at DCN PALAM daily including Saturday, Sunday and Gazetted Holidays complete all as specified and directed. Notes for Item No 1.00 :- (a)Periodical, preventive and comprehensive maintenance complete package chiller units 03 Nos, each consisting of 1 No 37.5 TR along with motor and its condenser,compressor, chillers, microprocessor based control panel complete systemdone through OEM i.e. any one ofM/sBlue Star/Trane/Voltas/ Hitachi including submission of quarterly service reports from OEM. Total No. Chiller units-03 Nos. (b)Preventive, comprehensive and routine maintenance of following equipments :- Details of the AC Plants:- (a) Centrifugal MonoblockPumps setfor Hot water Circulation Cap of 3 Hp, Make- Crompton – 02 Nos. (b) Centrifugal Monoblock Pumps set for Condenser water Circulation Cap of 5 Hp, Make-Kirlosaker- 03 Nos (c) Monoblock pumps for chilled water Circulation of cap 3Hp -03 Nos. (Make - Crompton). (d) Scroll TypeCommercial Compressors Cap of 12.5 TRMake- Danfoss, Model No- SZ185S4RC -09 Nos (e) Scroll Water Chiller, Make- Blue Star Cap of 37.5 TR Refrigerant – 407 C Model No- XWC3S039AR2 -03 Nos.
2NOTE FOR ITEM NOS. 1.00 (COntd...):- (f) Hot Water Generator Cap of 75 KW Make- Rapid Cool S.No- 195AC,HO19 -02 Nos. (g) FRP Induced Draft Cooling Tower Cap of 75 TR Make- Mihir , Model No- FH4- 02 Nos. (h)Double Skin Horizontal Mounted Air Handling Unit Cap of 29000 CFM,Make-Edgetech Air System Model- ETU300H, Coil-CHWCoil/ 1016 x 2653 / 6RD & Heating Coil / 1016 x 26532RD, Fan Model-Kruger / DIDW Backward / 1000, Motor- Siemens / 18.5 KW - 01 Nos. (j) Main HVAC Panel -01 Nos. (k) In case of break down, the additional manpower if required will be arranged by the contractor. The cost will be deemed to be included in Sch “A” items. (l) Contractor has to carry out all major and minor break down/repairs pertains to complete machineries of central AC Plant & connected cooling tower AHUs rates quoted is deemed to be included for all except any damage due to natural disasters such as flash, floods, earth quake, cyclone etc. (m) The contractor shall carry outroutine checking of the complete system and rectify the minor/major defects noticed immediately.Cleaning of fine air filter such a way that all AHUs are cleaned once in a month and making a maintenance register for above maintenance and one separate register to be maintained as complete register received from deptt and taking signature from users alter rectifying the defects if any. The contractor will arrange to clean all the grills/ducts/filters on regular basis with vaccurn cleaner & other appliances and record to be maintained. If complaints were not attended within six hours the following penalties will be imposed and deducted from payments. :- (i)Rs. 200/- for not attending the complaint and keeping pending from six hours to 12 Hour/per complaint. (ii)Rs. 500/- per complaint for not attending the complaint and keeping pending 12
3NOTE FOR ITEM NOS. 1.00 (Contd...) :- (n)Plant should be maintained to achieve temp 21 º C ± 2º C and relative humidity 50 ±5% or as per plant designed for. (o) Required refrigerant gas and compressor oil for maintenance of Plant are deemed to be included in the quoted rate. (p) The rates of note No. (a) to (p) above are deemed to be included in the quoted rates.
4Painting of the condensers, chillers, induction motors &pipe lines , valves and outer bodyof cooling towers with different colors following the color code system as directed by the Engineer in charge . Job includes removing the old paint by rubbing/ scrubbing and applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide zine chrome primer for centralAC plants of Cap 3×37.5 TR at DCN PALAM. complete all as specified and directed.
5Supply & fixing in repairs of cast iron butter fly valves lever operated SS disc type nitrile/EPDM rubber lining PN 16 of dia 125mm complete all as specified and directed.
6Supply & fixing in repairs of cast iron butter fly valves lever operated SS disc type nitrile/EPDM rubber lining PN 16 of dia 100mm complete all as specified and directed.
7Supply & fixing in repairs of cast iron butter fly valves lever operated SS disc type nitrile/EPDM rubber lining PN 16 of dia 80mm complete all as specified and directed.
8Supply & fixing in repairs of cast iron butter fly valves lever operated SS disc type nitrile/EPDM rubber lining PN 16 of dia 65mm complete all as specified and directed.
9Supply & fixing in repairs of cast iron butter fly valves lever operated SS disc type nitrile/EPDM rubber lining PN 16 of dia 50mm complete all as specified and directed.
10Supply & fixing in repairs ofcast iron Y strainer flanged ends with SS perforated sheet screen of size 100mm complete all as specified and directed.
11Supply & fixing in repairs of3 pole power contactor MNX-18 with NO + NC block ccomplete all as specified and directed.
12Supply & fixing in repairs of3 pole power contactor MNX-25 with NO + NC block complete all as specified and directed.
13Supply & fixing in repairs of3 pole power contactor MNX-32 with NO + NC blockcomplete all as specified and directed.
14Supply & fixing in repairs of3 pole power contactor MNX-40 with NO + NC block complete all as specified and directed.
15Supply & fixing in repair 3 pole power contactor MNX-50 with NO + NC block complete all as specified and directed.
16Supply & fixing in repairs of 3 pole power contactors typeMNX 70, AC-3 rating, 2NO + 2 NCcomplete all as specified and directed.
17Supply & fixing in repairs ofMCB SP 240 volts 6 to 32 Amps, 10 kA, "C" curve complete all as specified and directed.
18Supply & fixing in repairs ofMCB 3 pole 63 Amps, capacity 10kA, C curvecomplete all as specified and directed.
19Supply & fixing in repairs ofMCCB 100-125 Amps, capacity 25kA, 4 pole, 3 phase, 415 volts with thermal magnetic releasecomplete all as specified and directed.
20Supply & fixing in repairs of 30-120 Sec star delta timer timing and monitoring devices as per existing size and specification complete all as specified and directed.
21Supply & fixing in repairs of Single Phase Preventer of frequency 50-60Hz for submersible pump complete all as specified and directed.
22Supply & fixing in repairs ofover load relay 20-33 Amps complete all as specified and directed.
23Supply & fixing in repairs ofover load relay 14-23 Amps complete all as specified and directed.
24Supply & fixing in repairs ofover load relay 9-15 Amps complete all as specified and directed.
25Taking downfor servicingof split type AC 1.5/2 TR Capacityincluding cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing connections from heating mode to cooling mode or vice-versa and keepingthe AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all as specified and as directed.
26Taking downfor servicingofWindow type AC 1.5/2 TR Capacityincluding cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner OR cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing connections from heating mode to cooling mode or vice-versa andkeepingthe AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing positioncomplete all as specified and directed. Notes for Ser Item No 23 & 24 :- (i) Replacement of defectivespares for making the AC units in satisfactory working conditionwill be measured & paidseparately under relevant items and Labour charges for taking out old spares & refixing of new sparesshall deemed to be included in unit quoted rate. (ii) Penaltywill be charged for not attending complaint from 12 Hoursto 24 hours Rs. 500/- each complaint. Furtherif complaint not attended and rectifiedwithin 24 hours after intimation (Intimation will be given by message/whats app/mail by mentioningtime of complaint,for that contractor has to submit his authorised reps details for receiving complaint) of complaint, failing which same will be got rectified through spot quotation by job order by any other agency and double of the job order amount to be deducted from contractors dues.
27Supply only 15mm dia PVC pipe medium grade including fittings.
28Supply only printed circuit board (PCB) compatible with electric accessories and sensors for split type AC/ window type AC of capacity of 1.5/ 2 TR.
29Supply only starting capacitors 80-100 MFD.
30Supply only starting capacitors 100-120 MFD.
31Supply only running capacitor 50+6 MFD.
32Supply only running capacitor 45+5 MFD.
33Supply and fixing in repairs of condenser mortor 1/3 HP suitable for window type AC double shaft.
34Supply only starting relay SR-1622.
35Supply only running capacitor 36 MFD.
36Supply only thermostat switch 2059/ 2064/ 2054.
37Supply only copper filter double capilary pencil type.
38Supply only regulator knob suitable for 1.5TR /2 TR capacity AC.
39Supply only PVC insulated multi-stranded 3 core flexible copper cable of size 2.5 sqmm. Note for item No 25 to 30 & 32 to 37:- Materials of item No 25 to 30 & 32 to 37 to be incorporated in item No 23 & 24 here-in-before.
40Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the window type Air Conditioner of Cap2 Ton,of any make any type from any locationandSupply , Installingand testing of new sealed unit compressorandone yearguarantee certificate includingcleaning and removing dust/dirt from the cooling coil condenser coilwith necessary modification capillary tube etc&Charging of Gas R-22/R-410A/R-32 and commissioning complete all as specified and directed. Note :- Transportation Charges from siteto trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above.
41-ditto- all as per item No. 38 abovebut window type Air Conditioner ofCapacity1.5 TR.
42-ditto- all as per item No. 38 abovebut spilt type Air Conditioner ofCapacity 2 TR.
43-ditto- all as per item No. 38 above but spilt type Air Conditioner Capacity 1.5 TR.
44Supply & fixing in repairs 1.5 TR capacity window type AC kit including condenser coil, cooling coil, front grill blower motor, chasis, base plate complete set except compressor complete all as specified and directed.
45-ditto- all as per item No. 42 abovebut window type Air Conditioner ofCapacity 2.0 TR.B58
46Taking down unserviceable indoor unitof split AC of any make andsupply & fixing new indoor unit complete set suitable for 1.5 TRcapacity complete all as specified and directed.
47All as per item No. 44 above but spilt type Air Conditioner of capacity2 TR.
48Supply and fixing in repairs of1.5TR capacity split type Air Conditione outdoor kit including condenser coil, blower motor, chasis, base plate complete set except compressor complete all as specified and directed.
49-ditto- all as per item No. 46 above but spilt type Air Conditioner of capacity2 TR.
50Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded,unsheathed1100 volts grade in PVC casing caping(heavy grade) of adequit size with all fittings and casing capingaccessories of surface type including one run 6 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694)as earth wire including taking down old unserviceablesub main wiring complete all as specified and as directed. {Note :-(i) Two runs of cable with one runs earth wire and PVC casing capping shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the casing capping. (iv) Suitable color code of wire must be ensured for phase/ neutral/ earth.}
51Supply & fixing in repairs industrial type plug with two pin and earth confirming to IS/IES-309 of capacity 20 Amps complete all as specified and as directed.
52Supply and fixing in repairs metal clad socket outlet with single pole and nuetral enclosure with two pin and earth plug socket complete with one single pole MCB 32 Amps including taking down old unserviceablemetal clad socket complete all as specified and as directed.
53Material and labour for detecting of leakages of gases in window type /Split Type AC unit of capacity 1.5/2 TR at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition complete all as specified and as directed.
54Supply and fillingrefrigerant gas R-22/R-410A/R-32/R-134A in window type /Split Type AC unit of capacity 1.5/2 TR, Deep Freezer, Refrigerator, Water Cooler of any capacity complete all as specified and as directed.
55Supply and fixing in repairs of front grill of window type AC of capacity 1.5 TRcomplete all as specified and directed.
56Supply and fixing in repairs of front grill of window type AC of capacity 2.0 TRcomplete all as specified and directed.
57Taking down unserviceable reversible valve for split/ window type AC of capacity 1.5TR and supply & fixing new reversible valve with solenoid coil including required copper pipe complete all as specified and as directed. (Note:- Supply & filling of refrigerant gasshall be measured and paid under relevent item.)
58-ditto- all as per item No. 55 above but spilt/window type Air Conditioner of capacity2 TR.
59Supply & fixing heavy duty copper pipe 6mm (1/4") dia/ bore complete including insulation brazing, welding, nuts,bolts and screws of required size complete all as specified and as directed.
60-ditto- all as per item No. 57 above but copper pipe 12mm (1/2") dia/ bore.
61-ditto- all as per item No. 57 above but copper pipe 15mm (5/8") dia/ bore.
62Supply and fixing in repair of out door stand for split type AC, desert cooler of any capacity made up of angle iron frame of any size grouting on wall or floor as directed and applying of two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide zinc chrome primer including taking down old unserviceable one complete all as specified and directed.
63Supply & fixing in repair Indoor Air blower motor for Split type AC 1.5 TR & 2 TR capacity complete all as specified & as directed.
64Supply & fixing in repair Window AC air blower motor for 1.5 TR & 2 TR capacity AC complete all as specified & as directed.
65Supply & fixing in repairs Window AC condenser fan blade plastic body for 1.5 TR & 2 TR capacity AC complete all as specified & as directed.
66Supply & fixing in repairsSplit AC Condenser fanblade plastic body for 1.5 TR & 2 TR capacity AC complete all as specified and as directed.
67Supply & fixing in repairs running capacitor of 2.5 MFD capacity complete all as specified & as directed.
68Supply & fixing in repairs running capacitor of 4 MFD capacitycomplete all as specified & as directed.
69Supply & fixing in repairsrunning capacitor of 6 MFDcapacitycomplete all as specified & as directed.
70Supply only remote control including battery for split AC Cap 1.5/2 TR of make as per site requirement and replacement of old one complete all as specified and as directed.
71Supply & fixing in repairs plastic louvers for (Front panel)for Window type AC of capacity 1.5/2 TR complete all as specified and as directed.
72Supply & fixing in repairs of selector switch for fan/cooling of Window AC 1.5/2 Ton complete all as specified and as directed.
73Supply & fixing in repairs of suctionand discharge valve set of size 15mm (5/8""), 6mm (1/4"") and 12mm (1/2"")for Split AC 1.5/2 TR capacity complete all as specified and as directed {Note:-(i) 15mm (5/8"") or 6mm (1/4"") and 12mm (1/2"") made one set (ii) Supply & filling of refrigerant gasshall be measured and paid under relevent items.}
74M&L for 4 mm thick plywood of grade BWR, type BB including necessary fixing accessories and taking down old one and applying two coat of synthetic enamel paint(1st grade quality) over a coat of pink primer complete all as specified and as directed.
75Disconnecting the mains and taking out the unserviceable condenser coilof window type AC of capacity 1.5/ 2TR of any make from any location and supply, fixing and testing new condenser coil as per existing size & patterns complete all as specified and as directed. (Make:-Suitable for Voltas/Carrier/LG/ Hitachi/ Blue Star)
76-ditto- all as per item No. 73 above but spilt type Air Conditioner Capacity 1.5/ 2 TR.
77Taking down unserviceable insulation for copper pipe of any dia, supply and fixing new insulation for copper pipes suitable for Split AC of capacity from 1.5 to 2.0 TR complete all as specified and as directed.
78Taking down unserviceable contactor for split type AC of capacity 1.5 TR/ 2.0TR, supply and fixing new contactor single phase suitable for split type ACcomplete all as specified and as directed.
79Disconnection and removing of serviceable window type AC of capacity 1.5 TR/ 2.0TR of any make and model along with stabilizer from its position and fixing the same in other location including all other fixing accessories and testing complete all as specified and as directed.
80Disconnection and removing of serviceable split type AC of capacity 1.5 TR/ 2.0TR of any make and model along with stabilizer (Indoor & Outdoor Unit) from its position and fixing the same in other location including all other fixing accessories and testing complete all as specified and as directed.
81Disconnecting the unserviceable PCB compatible from existing Window/ Split type AC of capacity 1.5/ 2TR and refixing after necessary repair for satisfactory functioning of the AC unit complete all as specified and as directed.
82Dismantling and removing defective burnt blower unit motor ofcapacity 1.5/ 2.0 TR of any make ofwindow type AC and rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete all as specified and as directed.
83Dismantling and removing defective burnt blower unit motor ofcapacity 1.5/ 2.0 TR of any make of indoor units of split type AC and rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete all as specified and as directed.
84Dismantling and removing defective burnt blower unit motor ofcapacity 1.5/ 2.0 TR of any make of outdoor units of split type AC and rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete all as specified and as directed.
85Supply & fixing in repairs of blower fan blade of indoor unit for Split 1.5 TR & 2 TR capacity complete all as specified & as directed.
86Supply & fixing in repairs of metal clad socket of 20 Amps complete all as specified & as directed.
87Collecting of unserviceablevoltage stabilizerof capacity 2 to 5 KVA from the MES store yard of AGE or dismantlingthe same from site and transporting to contractors workshopfor locating the fault includingcheckingthe serviceability of electrical/electronic circuits relays andreplacement of defective spare parts , reassembling after making connections, testing by applying low and high voltage input to get the 230 volts correct output and transporting back the same to MES store yard complete all as specified and as directed. Note :- 1. Replacement of defectivespares and rewinding of transformer of voltage stabilizerwill be measured & paidseparately under relevant items and Labour charges for taking out old spares & fixing of new sparesshall deemed to be included in unit rate quoted.
88Supply onlyfollowing new spare partsof Voltage stabilizerofcapacity 2 to 5 KVA :-
89Voltmeter (Analog) 0 to 300 volts any type shape single phase 50 Hz AC supply
90Digitaltype Voltmeter0 to 300 volts any type shape single phase 50 Hz AC supply,
91Printer circuit control card suitable for 2 to 5 KVA.
92Input/output switch
93Push on switch
94Indicator with neon bulbs
95Trigger Transformer for 2 to 5 KVA.
96Relay for 2 to 5 KVA voltage stabilizer
97Time relay and High/low voltage cut off circuit with relay suitable for 2 KVA to 5 KVA Note for item No 86.01 to 86.09 :- Materials of item No 86.01 to 86.09 to be incorporated in item No 85.00 here-in-before
98Taking out the burnt winding of transformer of voltage stabilizer and preparing core after cleaning by suitable cleaning agent and rewinding the transformer of voltage stabilizer with super enameld copper wire of existing gauge including varnishing, heating and refiting of capacity 2KVA voltage stabilizer, complete all as specified and as directed.
99-ditto- all as per item No 87.00 here-in-before but 4 KVA.
100-ditto- all as per item No 87.00 here-in-before but 5 KVA.
101Disconnecting from mains and taking downfor servicingofWater Cooler ofCapacity 40/80, 60/120,Ltrs including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs,fan andblower, etc., andkeepingthe Water coolerunit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed. Note :- 1. Replacement of defectivespares for making the water cooler units in satisfactory working condition will be measured & paidseparately under relevant items and Transportation & labour charges for taking down old spares and fixing of new sparesshall deemed to be included in unit rate quoted above.
102Supply onlyfollowing new spare parts of Water cooler unit ofcapacity 40/80 to 60/120 Ltrs:-
103Starting relaysuitable for 40/80 , 60/120 Ltr.
104Starting Capacitor 25 MFD.
105Running Capacitor 10 MFD .
106PVC flexible drainHose pipe 40 mm.
107Condenser fan blade aluminium body for Motor 1/32HP, 1/35HP .
108Over load protector device for 60/120 ltrs capacity water cooler.
109Over load protector device for 40/80 ltrs capacity water cooler.
110Thermostat switch.
111Self closing chromium plated push taps for water cooler Capacity 40/80,60/120 Ltr. Note for item No 91.01 to 91.09 :- Materials of item No 91.01 to 91.09 to be incorporated in item No 90.00 here-in-before
112Disconnecting the electric and Water connections and taking out the existing unserviceable compressor of any make from water cooler storage type capacity60/120 Ltrs from any location andsupply installation & testing of new sealed unit compressorof similar capacity in same locationalongwith test Certificate from manufacturer and cleaning of condenser by machine doing vacum the fully system and supply and charging of oil gas and other necessary lubricants including reconnecting the electric and water connections, transportaion& testing complete all as specified and as directed.
113-ditto- all as per item No. 92.00 above butWater coolerofcapacity 40/80 Ltrs.
114Disconnecting the electric mains and taking out unserviceable condenser fan motor1/10 HP from water cooler cap.60/120 Ltr and supply and replace with new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as specified and as directed.
115All as per item No. 94 above but 1/32 HP Water coolerofCapacity 40/80 Ltrs.
116Disconnecting the mains and taking out the unserviceable condenser coil and supply & fixing new condenser coil as per existing size & patterns for Water/Coolers of capacity 60/120 Ltrs complete all as specified & as directed.
117Disconnecting the mains and taking out the unserviceable condenser coiland supply & fixing new condenser coil as per existing size & patterns for Water/Coolers of capacity 40/80Ltrs complete all as specified & as directed.
118Dismantling the evaporator/cooling coil of water cooler capacity 60/120 & 40/80 Ltrs, checking the leakages of gas and rectify the leakages by brazing or as other manner and refixing in same position complete all as specified and as directed.
119Cleaning & removing the existing paint ofWater Coolers capacity60/120 & 40/80 Ltrs by rubbing & preparing the surface smooth & applying one coat of zinc chrome primer and two coats of synthetic enamel paint (1st grade quality) by spray gun machine of colour complete all as specified and as directed.
120Taking up or down GI steel tubing 15mm bore with connection and removing from site complete all as specified and as directed.
121Supply and fixingGI steel tubing 15 mm bore, medium grade with all fittings (such as bends, elbows, tees, short plugs and union etc.)fixed on wall or floor complete all as specified and as directed.
122Supply and fixing in repairs Stop valve 15mm bore dia, fancy type chromium plated with long shank and cup (concealed type), screwed both ends for iron pipe or for unionscomplete all as specified and as directed.
123Taking down unserviceable PVC connection pipe and Supply and Fixing of PVC connections pipe of 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified & as directed.
124Material and labour for detecting of leakages of gases in Water cooler, Refrigerator, deep freezer of any capacity at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition.
125Disconnecting from mains and taking downfor servicingof Refrigerator/Deep freezerofCapacity 165/180/195/310/330/450 and 500 Ltrsincluding detecting the leakage of gas and refilling of refrigerant ,cleaning of cooling coil, condenser, compressors, with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., andkeepingthe Refrigerator unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required complete all as specified and as directed. Note :- 1. Replacement of defectivespares for making the Refrigerator/ Deep Freezer units in satisfactory working condition will be measured & paidseparately under relevant items and Labour charges for taking out old spares and fixingof new sparesshall deemed to be included in unit rate quoted.
126Supply onlyfollowing new spare parts of Refrigerator/Deep freezer 165/180/195/310/330/450 and 500 Ltrs capacity:-
127Thermostat switchwith Knob.
128Starting relay 1/6 H.P.Open type with O.L.P.
129Starting relay 1/8 H.P. open type with O.L.P.
130Copper filter single capilary pencil type.
131Vegetable tray PVC for 165 to 330 Ltr capacity (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator).
132Defrost tray for refrigerator capacity 165 to 330 Ltr(Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator).
133PVC ice tray flexible(Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator).
134Refrigerator bottle shelf for 165 to 330 ltr capacity(Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator).
135Waste water tray suitable for different type of Refrigerator (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator).
136Freezer door for 165/180/195 Ltr capacity(Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator).
137Freezer door for 280/300/330 Ltr capacity (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator).
138Door Lock for refrigerator 165 to 330 ltrs (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator).
139Door switch for refrigerator 165 to 330 ltrs (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator).
140Interior light fittings with bulb(Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator).
141Door handle suitable for 165 to 330 Ltrs (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator).
142Refrigerator Glass shelves of capacity 165/180/195 Ltrs (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator).
143Refrigerator Glass shelves of capacity 280/300/310/330 Ltrs (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator). Note for item No 106.01 to 106.17 :- Materials of item No 106.01 to 106.17 to be incorporated in item No 105.00 here-in-before.
144Disconnecting from mains and taking down the unserviceable compressorunit of Refrigerator of any make and type and providing New Compressor suitable for 165 to 195 ltr capacityalongwith test certificate from manufacturer including supply of therefrigerant gas R-134A and filling and replacement of filter and put in working condition all as directed by Engineer-in-Charge. Note :-The rates quoted by the contractor shall deemed to include the transportation cost from site of installation to contractor"s repair workshop and back.
145All as per item No. 107above but following capacity of Refrigerator:-
146Refrigerator 280/300/310/330 Ltrs capacity.
147Deep Freezer 400 Ltrs capacity.
148Deep Freezer 500 Ltrs capacity.
149Taking out unserviceable evaporator /freezer from the refrigerator & supply & fixing evaporator/freezer made out of aluminium press type of capacity 280/300/310/330/400 and 500 ltrwith freezer frame and door including connection, complete all as specified & as directed.
150ditto- all as per item No. 109 but capacity of the refrigerator 165 to 195Ltrs capacity.
151Taking down desert cooler of any type (Steel body/Plastic body) and any capacity from any height / floor andrefixing the same in same location after repair work/ overhauling complete all as specified and as directed. Note:- Repair work not included in the quoted rate.
152Preparation for old painted surface of desert cooler of any capacity and any make on inner surface & outer surface.Repainting the complete desert coolers ie side panel, bracket, body & desert cooler stand with two coats of synthetic enameled paint (1st grade quality) including two coats of black water proof paint on reserve water tank & marking with “ GE(U) P&M (MES)” letter size of 50mm height in stencil in black/white including servicingandgreasing of fan motor/pump and replacement of PVC pipe worn out nut, bolts and washers complete all as specified and as directed.
153Supply and fixing in repairs wood wool padapproximate weight 800 - 900gms of size 24” sweep desert cooler as per existingcomplete all as specified and directed.
154-ditto- all as per item No 113 above but approximate weight 700 - 800gms and20” sweep.
155Supply and fixing in repairs submersible pump motor 230 Volts , single phase, AC suitable for Plastic body/ Steel body Desert cooler complete all as specified & as directed.
156Supply and fixing in repairs of exhaust fan motor copper woundedhaving 1400 RPM, 150 watts with 500mm sweep suitable for operation on 230 volts, 50Hz, AC supply including fan brackets/ clamps of suitable size and all fixing accessories complete all as specified & as directed.
157Supply and fixing in repairs of desert cooler copper wounded kitfan motor of capacity 90 Watt complete all as specified & as directed.
158Supply and fixing in repairs front grill for desert cooler of approved make complete with 5 Amp switch, three speed regulator including indicator lamp complete all as specified and directed.
159Supply & fixingin repairs GI wire mesh for desert cooler pad (Set of Three) complete all as specified and as directed.
160Supply & fixing in repairsPVC pipe for connecting pump and water distributor of size 15 mm complete all as specified & as directed.
161Supply & fixingin repairsPVC elbow for desert cooler of suitable size complete all as specified & as directed.
162Supply & fixingin repairs PVC 4 Way distribution cross for desert cooler complete all as specified & as directed.
163Supply & fixingin repairs flexible copper conductor cable, 3 corePVC insulated & PVC sheathed of size 1.5 sqmm complete all as specified and directed.
164Supply & fixing in repairs desert coolers fan blade of 18 inch sweep of plastic bodycomplete all as specified & as directed.
165ditto- all as per item No 124 here-in-before but 20 inch sweep.
166Supply and fixing in repairs side panel of desert cooler of 20” sweep made out with GI sheet of 20 SWG duly painted with two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide zinc chrome primer complete all as specified & as directed.
167Supply and fixing in repairs switch piano flush type single pole one way 5Amp / 6 Amp 230 V for desert cooler all as directed
168Supply and fixing in repairs 3 pin plug top 5 Amp, 230V for desert cooler complete all as specified and directed
169Supply and fixing in repairs 3 pin plug top 15 Amp, 230V for desert cooler complete all as specified and directed
170Supply and fixing in repairs cooler fan motor bracket sets made up as existing includingpaintingcomplete all as specified and directed.
171Supply & fixing in repairs desert cooler body of size 25 inch x 25 inch x 36 inch (height) with side panels (03 Nos) fabricated out of 20 SWG PGI Sheet alongwith PVC front grill, distribution switch, 5 Amp piano switch and tank of depth 11 inch. Painting the complete desert cooler i.e, side panel, bracket body with two coat of synthetic enamel paint (Ist grade quality) over a coat of red oxide zinc chrome primer and two coat of black water proof paint on reserve tank and marking with "GE (U) P&M (MES)" letter size of 50mm height in stencil in black/white complete all as specified and as directed.