| 1 | Pre Coated MS tubular sections, ‘C’ Frames/”J” Frames/ “H” Frames, with 40 x 60 mm, 16 Gauge OR 30 x 60 mm, 14 Gauge |
| 2 | 18mm Thick high quality jet blackor absolute black granite |
| 3 | 16mm Pheonlic Resin TRESPA Brand |
| 4 | Modular Fume Hood with blower as per spec |
| 5 | Under Bench Storage units as sper spec 450mmLx550mmD; 1 door, 1 drawer |
| 6 | Under Bench Storage units as sper spec 600mmLx550mmD; 1 door, 1 drawer |
| 7 | Under Bench Storage units as sper spec 750mmLx550mmD, 2 door, 1 drawer |
| 8 | Under Bench Storage units as sper spec 900mmLx550mmD, 2 door, 2 drawer |
| 9 | Reagent shelf two tier, 300mm - quote rate for one meter |
| 10 | Reagent shelf two tier, 150mm - quote rate for one meter |
| 11 | Reagent shelf single tier, 150mm - quote rate for one meter |
| 12 | Service box in reagent shelf |
| 13 | Cover / filler / Back panel - quote rate for one meter |
| 14 | Wall storage cupboard 900mm (W) X 300mm (D) x 600mm(H) |
| 15 | Wall storage cupboard 600mm (W) X 300mm (D) x 600mm(H) |
| 16 | Service Dropper - quote rate for one meter |
| 17 | Triangular Metal Electrical raceway - quote rate for one meter |
| 18 | Rectangular Metal Electrical raceway - quote rate for one meter |
| 19 | Sink |
| 20 | Eye wash |
| 21 | Laboratory Reagent Storage Full Height Storage Cabinets |
| 22 | Fumehood ducting - quote rate for one meter |
| 23 | Water tap one way |
| 24 | Three way water tap |
| 25 | Hand held eye wash |
| 26 | PP Transparent Back Slash Guard |
| 27 | Peg Board PP with Collection tray of 18 pegs |
| 28 | PU seated laboratory stool with back reat |
| 29 | PU seated laboratory stool without back rest |
| 30 | Floor mounted emergency shower with eye wash station (safety station) |
| 31 | Under Bench Storage units as sper spec 450mmLx550mmD; 1 door, 1 drawer - Plinth Type |
| 32 | Under Bench Storage units as sper spec 750mmLx550mmD, 2 door, 1 drawer - Plinth Type |
| 33 | Under Bench Storage units as sper spec 900mmLx550mmD, 2 door, 2 drawer - Plinth Type |
| 34 | Leg space assembly with back panel for Plinth type - quote rate for one meter |
| 35 | Vibration free table |
| 36 | Spot extractor |
| 37 | Corner Table with storage |
| 38 | Slotted angle rack |
| 39 | Providing and fixing LPG pipe: MS pipe 15mm, 1.5mm wall thick - Sub branches |
| 40 | Providing and fixing Vacuum pipe : MS pipe 28mm, 1.5mm wall thick - Header line |
| 41 | 1 LPG system, 4 manifold with NRV, pressure and release regulator 4 each and high pressure tail pipes |
| 42 | Brass 4 way valve with outlets |
| 43 | Isolation valves |
| 44 | Bunsen Burner |
| 45 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 46 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 47 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 48 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 X 1.5 sq.mm |
| 49 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm |
| 50 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 4 sq. mm |
| 51 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
| 52 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 53 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch |
| 54 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet |
| 55 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch |
| 56 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 5/15 amp socket outlet |
| 57 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module |
| 58 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 3 Module |
| 59 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 6 Module |
| 60 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall, making good the damages, colour washing etc. as required 6 way (8+18) - three phase double cover (IP 42/43) |
| 61 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps |
| 62 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
| 63 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps |
| 64 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
| 65 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 66 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes |
| 67 | Providing and fixing PVC pipes includingjointing of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge 40 mm dia 10Kgf/cm2 |
| 68 | Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC. waste fittings complete.Semi rigid pipe32 mm dia |
| 69 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore |
| 70 | Providing and fixing uplasticised PVC connection pipe with brass unions:30 cm length15 mm nominal bore |