Re-Wiring Of Powerhouse, Lighthouse Tower And Electrification Of Inspection Quarter, Alk Quarters, Security Room, Pumphouse And Provision Of Additional Streetlight At Beypore Lighthouse.
Tender Overview
Project Description
Re-Wiring Of Powerhouse, Lighthouse Tower And Electrification Of Inspection Quarter, Alk Quarters, Security Room, Pumphouse And Provision Of Additional Streetlight At Beypore Lighthouse.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 03-Aug-2022 | CORRIGENDUM (I) - EXTENSION OF DATE | Date | 16-Aug-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Annexure-I: Rewiring of Powerhouse and Office Building at Beypore Lighthouse |
| 2 | MODULAR SWITCH BOXES, SWITCHES AND SOCKETS |
| 3 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2Module (75mm * 75mm) |
| 4 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.3Module (100mm * 75mm) |
| 5 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4Module (125mm * 75mm) |
| 6 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 or 8Module (125mm * 125mm) |
| 7 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6A switch |
| 8 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 6A socket outlet |
| 9 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 6/16A socket outlet |
| 10 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet |
| 11 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet |
| 12 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 13 | Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 14 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 15 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 16 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 17 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 18 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Up to 450mm |
| 19 | Extra for fixing the louvers/ shutters complete with frame for an exhaust fan of all sizes |
| 20 | Supplying and fixing of Conduit and Cable |
| 21 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20/25 mm |
| 22 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5sq. mm (Point wiring) |
| 23 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5sq. mm (Submains - 4 Circuit, 6A Socket -7 circuit and Link sub mains - 7 circuit) |
| 24 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4sq. mm (Power Socket - 7circuit) |
| 25 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 pair |
| 26 | Switch Gear |
| 27 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A |
| 28 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 6A - 3Nos, 10A - 8Nos, 16A - 7Nos. |
| 29 | Earthing |
| 30 | Earthing with G.I. earth pipe 4.5m long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (LT DB Earths and Lighting MCB DB - 2 Earth) |
| 31 | Providing and laying earth connection from earth electrode with 4.00mm (8SWG) dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 32 | Providing and fixing 4.00mm dia copper wire on surface or in recess for loop earthing as required. |
| 33 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (For DG set Earthing) |
| 34 | Supplying and laying 25mm X 5mm copper strip at 0.50m below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 35 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 32A one-way double pole switch with indicator - 2 module |
| 36 | Supply and installation of ETPN DB 6 way (8+18) IP 43 - #IK 09 with metal door, Conforming to IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, with 100 A Copper Bus bar for each phase, with Neutral bar, Earth bar and Cable ties for Cable management, Fully insulated bus bar & shrouded Neutral bars, Improved Pan assembly for ease of installation, Pre-fitted masking sheet, Reversible Door, with provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP MCB\"s as outgoing and Supplied with wire set, Legrand Ekinox³ 5076 71 or equivalent reputed make and model as required. |
| 37 | Supplying and fixing following rating, four pole, 415V, MCB,10kA as per IS/IEC 60898-1 2002, in the existing MCB DB complete with connections, testing and commissioning etc. as required. Legrand DX³ MCBs 4087 02 or equivalent from ABB,Havells, Schneider Electric. 63A |
| 38 | Supply and fixing of SMC JB with Krone connector for incoming Telephone Supply, Sintex make GSJB 1510 Model or equivalent reputed make and model as required |
| 39 | Indoor Industrial Tube Light Battens, with LED Tube, double side connection (inclusive), Philips TMC 501/Core Line Batten with 20W, 1200mm, Core Pro LED Tube/ Havells Regal Batten with 18/20W, 1200mm, Crystal Glass LED Tube or Equivalent model of Reputed make as required. |
| 40 | Bulk Head Luminaries IP65/66/67 IK09/10 with integrated LED source, Philips WT202 10W IP66, Havells Hexa 10W IP66/Equivalent model of Crompton |
| 41 | 10.5 - 15W LED Bulb, Philips Core pro LED Bulb / Havells Adore LED Bulb make or Equivalent model of Reputed make as required. |
| 42 | Wall Mounting Luminaries, Luker, AETHER Indoor Wall Light Series-3 7W/Series-4 7W/Series-5 7W or Equivalent model of Philips,Havells. |
| 43 | Exhaust Fan, 450mm sweep Metallic DBB, Almonard/Havells/Crompton. |
| 44 | Ceiling Fan, Electrophoretic lacquered/Electroplated surface for anti-rusting, High speed fan with wider tip blade for effective air circulation, double ball bearing with Sweep 1200mm and High performance even at low voltage, Havells SS390 or Equivalent model from Almonard/Havells/Crompton. |
| 45 | Fabrication and supply the louvers/ shutters complete with frame for an exhaust fan, Fabricated out ofAluminium sheet and frame. Including materials and painting / Powder coating |
| 46 | Termination and Integration of newly laid UG Cables (Lighthouse Tower, Main Light, Automation, Inspection Quarter) for Distribution in to the existing EAMF Panel |
| 47 | Termination and Integration of the LT Power UG Cable from KSEB Meter into the existing LTDB Panel |
| 48 | Miscellaneous items for the purchase of screws, Bolts, Nuts & Washers, drill bits, cable ties, bends, tees, wire strippers, steel spring, cable glands, PVC junctions boxes etc., |
| 49 | Labour charges for dismantling old DB\"s, switch boxes, fittings and removing old wiring, etc. |
| 50 | Annexure-II : Rewiring of Inspection Quarter at Beypore Lighthouse |
| 51 | MODULAR SWITCH BOXES, SOCKETS AND SWITCHES |
| 52 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2Module (75mm * 75mm) |
| 53 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.3Module (100mm * 75mm) |
| 54 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4Module (125mm * 75mm) |
| 55 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 or 8Module (125mm * 125mm) |
| 56 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6A switch |
| 57 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2way 5/6 A switch |
| 58 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet |
| 59 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 6/16 A socket outlet |
| 60 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet |
| 61 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Bell push |
| 62 | Supplying and fixing call bell/ buzzer suitable for single phase, 230V, complete as required. |
| 63 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 64 | Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 65 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 66 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 67 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 68 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 69 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. - Up to 450mm (230mm sweep) |
| 70 | Supplying and fixing of Conduit and Cable |
| 71 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20/25mm |
| 72 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5sq. mm (Point wiring) |
| 73 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5sq. mm (Submains - 3 Circuit, 6A Socket -6 circuit and Link sub mains - 7 circuit) |
| 74 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4sq. mm (Power Socket - 5circuit, Industrial Socket - 3Circuit) |
| 75 | Switch Gear & DB |
| 76 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8way, Double door |
| 77 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A |
| 78 | Supplying and fixing following rating, double pole, (single phase and neutral), 240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 20/25A |
| 79 | Supplying and fixing 20A, 240V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 80 | Supplying and fixing 5A to 32A rating, 240/415V, 10kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 6A – 3Nos.,10A – 5Nos.,16A – 6Nos., 20A – 2Nos. |
| 81 | Supplying and fixing 5A to 32A rating, 240/415V, 10kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole 20A |
| 82 | Earthing |
| 83 | Earthing with G.I. earth pipe 4.5m long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 84 | Providing and laying earth connection from earth electrode with 4.00mm (8SWG) dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 85 | Providing and fixing 4.00mm dia copper wire on surface or in recess for loop earthing as required. |
| 86 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 32A one-way double pole switch with indicator - 2 module |
| 87 | Supply and installation of ETPN DB 6 way (8+18) IP 43 - #IK 09 with metal door, Conforming to IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, with 100 A Copper Bus bar for each phase, with Neutral bar, Earth bar and Cable ties for Cable management, Fully insulated bus bar & shrouded Neutral bars, Improved Pan assembly for ease of installation, Pre-fitted masking sheet, Reversible Door, with provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP MCB\"s as outgoing and Supplied with wire set, Legrand Ekinox³ 5076 71 or equivalent from ABB, Schneider electric ,Havells. |
| 88 | Supplying and fixing following rating, four pole, 415V, MCB,10kA as per IS/IEC 60898-1 2002, in the existing MCB DB complete with connections, testing and commissioning etc. as required. Legrand DX³ MCBs 4087 02 or equivalent from ABB, Schneider electric ,Havells. 63A |
| 89 | Supplying and fixing following rating, 400V, Changeover MCB, four pole, 2way, with centre off as per IS/IEC 60898-1 2002, in the existing MCB DB complete with connections, testing and commissioning etc. as required. Legrand DX³ Changeover switch 6040 22 or equivalent from ABB, Schneider electric ,Havells. 40A |
| 90 | Modular Buzzer, 230V AC, with 2 module GI box along with modular base & cover plate. Legrand Mylinc 6755 40 or equivalent reputed make and model in recess etc. as required |
| 91 | Supply and fixing of SMC JB with Krone connector for incoming Telephone Supply, Sintex make GSJB 1510 Model or equivalent reputed make and model as required |
| 92 | Indoor Industrial Tube Light Battens, with LED Tube, double side connection (inclusive), Philips TMC 501/Core Line Batten with 20W, 1200mm, Core Pro LED Tube/ Havells Regal Batten with 18/20W, 1200mm, Crystal Glass LED Tube or Equivalent model of Reputed make as required. |
| 93 | Bulk Head Luminaries IP65/66/67 IK09/10 with integrated LED source, Philips WT202 10W IP66, Havells Hexa 10W IP66/Equivalent model of Crompton |
| 94 | 10.5 - 15W LED Bulb, Philips Core pro LED Bulb / Havells Adore LED Bulb make or Equivalent model of Reputed make as required. |
| 95 | Wall Mounting Luminaries, Luker, AETHER Indoor Wall Light Series-3 7W/Series-4 7W/Series-5 7W or Equivalent model of Philips,Havells. |
| 96 | Exhaust Fan, 230mm sweep Metallic DBB, Almonard/Havells/Crompton or Equivalent model of Reputed make as required. |
| 97 | Ceiling Fan, Electrophoretic lacquered/Electroplated surface for anti-rusting, High speed fan with wider tip blade for effective air circulation, double ball bearing with Sweep 1200mm and High performance even at low voltage, Havells SS390 or Equivalent model of Almonard/Crompton. |
| 98 | Wall Mounting Mirror Fittings, 11/12/13W, IP42, Aluminium body, LED Light source, Luker Helios 11/13W make Model LMR9/LMR12 or Equivalent model of Reputed make as required. |
| 99 | RO Water Purifier 8liter capacity, RO + UF + TDS Control + UV in Tank, fully automatic with auto cut off, KENT Supreme 2020 or equivalent from Aquaguard,Vguard. |
| 100 | 1.5 Ton Air Conditioner 5 star rated, anti-corrosive blue fin copper condenser, R22 Refriegerant/R410A Eco- freindly Refrigerant, Blue Star S-series make with 4KVA Stabilizer V-guard or any other reputed make and GI Stand for Outdoor Unit |
| 101 | 43”-inch full HD LED TV, Sony/Samsung/LG make. |
| 102 | Refrigerator 190L, 5star rated, Single Door (Bosch/LG/Samsung) |
| 103 | Washing Machine 6 Kg front load, 5 star rated (IFB/LG/Samsung) |
| 104 | Dish TV connection for TV with all accessories |
| 105 | 10L Storage Water Heater, 5 star rated, Vertical/Horizontal mounting type, Racold Eterno 2 make or equivalent reputed make and model as required |
| 106 | Miscellaneous items for the purchase of screws, Bolts, Nuts & Washers, drill bits, cable ties, bends, tees, wire strippers, steel spring, cable glands, PVC junctions boxes etc., |
| 107 | Labour charges for dismantling old DB\"s, switch boxes, fittings and removing old wiring, etc. |
| 108 | Annexure-III : Rewiring of ALK Quarter at Beypore Lighthouse |
| 109 | MODULAR SWITCH BOXES, SOCKETS AND SWITCHES |
| 110 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2Module (75mm * 75mm) |
| 111 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.3Module (100mm * 75mm) |
| 112 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4Module (125mm * 75mm) |
| 113 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 or 8Module (125mm * 125mm) |
| 114 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6A switch |
| 115 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2way 5/6A switch |
| 116 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6A socket outlet |
| 117 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 6/16 A socket outlet |
| 118 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Bell push |
| 119 | Supplying and fixing call bell/ buzzer suitable for single phase, 230V, complete as required. |
| 120 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 121 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 122 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 123 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 124 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 125 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 126 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. - Up to 450mm (230mm sweep) |
| 127 | Supplying and fixing of Conduit and Cable |
| 128 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20/25mm |
| 129 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5sq. mm (Point wiring) |
| 130 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5sq. mm (Submains - 3 Circuit, 6A Socket -5 circuit and Link sub mains - 6 circuit) |
| 131 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4sq. mm (Power Socket - 3 circuit) |
| 132 | Switch Gear & DB |
| 133 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16way, Double door |
| 134 | Supplying and fixing following rating, double pole, (single phase and neutral), 240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A |
| 135 | Supplying and fixing 5A to 32A rating, 240/415V, 10kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 6A – 3Nos.,10A – 5Nos.,16A – 3Nos. |
| 136 | Earthing |
| 137 | Earthing with G.I. earth pipe 4.5m long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 138 | Providing and laying earth connection from earth electrode with 4.00mm (8SWG) dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 139 | Providing and fixing 4.00mm dia copper wire on surface or in recess for loop earthing as required. |
| 140 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 32A one-way double pole switch with indicator - 2 module |
| 141 | Modular Buzzer, 230V AC, with 2 module GI box along with modular base & cover plate. Legrand Mylinc 6755 40 or equivalent reputed make and model in recess etc. as required |
| 142 | Supplying and fixing following rating, double pole, 415V, MCB,10kA as per IS/IEC 60898-1 2002, in the existing MCB DB complete with connections, testing and commissioning etc. as required. Legrand DX³ MCBs 4087 37 or equivalent reputed make ABB, Schneider electric ,Havells. 40A |
| 143 | Supply and fixing of SMC JB with Krone connector for incoming Telephone Supply, Sintex make GSJB 1510 Model or equivalent reputed make and model as required |
| 144 | Indoor Industrial Tube Light Battens, with LED Tube, double side connection (inclusive), Philips TMC 501/Core Line Batten with 20W, 1200mm, Core Pro LED Tube/ Havells Regal Batten with 18/20W, 1200mm, Crystal Glass LED Tube or Equivalent model of Reputed make as required. |
| 145 | Bulk Head Luminaries IP65/66/67 IK09/10 with integrated LED source, Philips WT202 10W IP66, Havells Hexa 10W IP66/Equivalent model of Crompton. |
| 146 | 10.5 - 15W LED Bulb, Philips Core pro LED Bulb / Havells Adore LED Bulb make or Equivalent model of Reputed make as required. |
| 147 | Wall Mounting Luminaries, Luker, AETHER Indoor Wall Light Series-3 7W/Series-4 7W/Series-5 7W or Equivalent model of Philips,Havells. |
| 148 | Exhaust Fan, 230mm sweep Metallic DBB, Almonard/Havells/Crompton. |
| 149 | Miscellaneous items for the purchase of screws, Bolts, Nuts & Washers, drill bits, cable ties, bends, tees, wire strippers, steel spring, cable glands, PVC junctions boxes etc., |
| 150 | Labour charges for dismantling old DB\"s, switch boxes, fittings and removing old wiring, etc. |
| 151 | Annexure-IV : Rewiring of Lighthouse Tower of Beypore Lighthouse |
| 152 | MODULAR SWITCH BOXES, SOCKETS AND SWITCHES |
| 153 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2Module (75mm * 75mm) |
| 154 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.3Module (100mm * 75mm) |
| 155 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4Module (125mm * 75mm) |
| 156 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 or 8Module (125mm * 125mm) |
| 157 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6A switch |
| 158 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6A socket outlet |
| 159 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 6/16A socket outlet |
| 160 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet |
| 161 | Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 162 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 163 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 164 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 165 | Cables |
| 166 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5sq. mm (for wall fan and light points in service room and tower bottom) |
| 167 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5sq. mm (for 6A Socket - 4ckts) |
| 168 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4sq. mm (for 16A sockets - 3ckts) |
| 169 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 pair |
| 170 | Switch Gear & DB |
| 171 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4/6way, Double door |
| 172 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12way, Double door |
| 173 | Supplying and fixing following rating, double pole, (single phase and neutral), 240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40A |
| 174 | Supplying and fixing following rating, double pole, 240 V, isolator in the commissioning etc. as required. existing MCB DB complete with connections, testing and and commissioning etc. as required.40A |
| 175 | Supplying and fixing 5A to 32A rating, 240/415V, 10kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 6A – 2Nos.,10A – 3Nos.,16A – 3Nos. |
| 176 | Earthing |
| 177 | Earthing with G.I. earth pipe 4.5m long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 178 | Earthing with copper earth plate 600mm X 600mm X 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7m long etc. with charcoal/ coke and salt as required. (for Lightning Arrester Earthing) |
| 179 | Providing and laying earth connection from earth electrode with 4.00mm (8SWG) dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 180 | Providing and fixing 4.00mm dia copper wire on surface or in recess for loop earthing as required. |
| 181 | Supplying and fixing of following sizes of Heavy class FRLS uPVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 25mm |
| 182 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 32A one-way double pole switch with indicator - 2 module |
| 183 | 20A, 230V AC, 2way double pole switch with 2 module GI box along with modular base & cover plate. Legrand Lyncus 6772 15 or equivalent reputed make and model in recess etc. as required |
| 184 | Indoor Industrial Tube Light Battens, with LED Tube, double side connection (inclusive), Philips TMC 501/Core Line Batten with 20W, 1200mm, Core Pro LED Tube/ Havells Regal Batten with 18/20W, 1200mm, Crystal Glass LED Tube or Equivalent model of Reputed make as required. |
| 185 | Bulk Head Luminaries IP65/66/67 IK09/10 with integrated LED source, Philips WT202 10W IP66, Havells Hexa 10W IP66/Equivalent model of Crompton |
| 186 | Wall Mounting Luminaries, Luker, AETHER Indoor Wall Light Series-3 7W/Series-4 7W/Series-5 7W or Equivalent model of Philips,Havells. |
| 187 | Wall Mounting Fan, 400mm sweep, Hi-Speed, Usha/Havells/ Almonard/Crompton make |
| 188 | Supply of Un-armoured, 4Core x 6sq.mm, All Copper Conductor - Solid / Stranded Non Compacted Circular, HR PVC/ XLPE Insulation, conforming to standards: as per IS 1554 Part-1&2 & IS 7098 Part-1&2, reputed make as required. (from Tower Base DB to Service Room DB Automation and Tower Lighting) |
| 189 | Supply of Un-armoured, 3Core x 1.5sq.mm, All Copper Conductor - Solid / Stranded Non Compacted Circular, HR PVC/ XLPE Insulation, conforming to standards: as per IS 1554 Part-1&2 & IS 7098 Part-1&2, reputed make as required. (from Tower Base DB to Service Room DB Main light, Automation and Tower Lighting) |
| 190 | Supply of Un-armoured Cable, 3Core x 4sq.mm, All Copper Conductor - Solid / Stranded Non Compacted Circular, HR PVC/ XLPE Insulation, conforming to standards: as per IS 1554 Part-1&2 & IS 7098 Part- 1&2, reputed make as required. (from Tower Base DB to Service Room DB Main light) |
| 191 | Drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. - 4Core x 6sq.mm / 3Core x 4sq.mm / 3Core x 1.5 sq.mm |
| 192 | Core Cutting charges for Laying Conduits in stair case steps from tower Bottom to Top. |
| 193 | Cable laying charges from power house to Tower bottom and Tower bottom to service room |
| 194 | Labour charges for dismantling old DB\"s and switch boxes, fittings and removing old wiring |
| 195 | Miscellaneous items for the purchase of screws, Bolts, Nuts & Washers, drill bits, cable ties, bends, tees, wire strippers, steel spring, cable glands, PVC junctions boxes, cement, etc., |
| 196 | Annexure-V : Electrification for Security Room at Beypore Lighthouse |
| 197 | MODULAR SWITCH BOXES, SOCKETS AND SWITCHES |
| 198 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.3Module (100mm * 75mm) |
| 199 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4Module (125mm * 75mm) |
| 200 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 or 8Module (125mm * 125mm) |
| 201 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6A switch |
| 202 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6A socket outlet |
| 203 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 6/16A socket outlet |
| 204 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet |
| 205 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 206 | Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 207 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 208 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 209 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 210 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 211 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. - Up to 450mm (230mm sweep) |
| 212 | Extra for fixing the louvers/ shutters complete with frame for an exhaust fan of all sizes |
| 213 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20/25mm |
| 214 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5sq. mm (Point wiring) |
| 215 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5sq. mm (Submains - 1 Circuit, 6A Socket -1 circuit 1) |
| 216 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4sq. mm (Power Socket - 1 circuit) |
| 217 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 pair |
| 218 | Switch Gear & DB |
| 219 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16way, Double door |
| 220 | Supplying and fixing following rating, double pole, (single phase and neutral), 240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A |
| 221 | Supplying and fixing 5A to 32A rating, 240/415V, 10kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 6A – 1No.,10A – 1No.,16A – 1No. |
| 222 | Earthing |
| 223 | Earthing with G.I. earth pipe 4.5m long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 224 | Providing and laying earth connection from earth electrode with 4.00mm (8SWG) dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 225 | Providing and fixing 4.00mm dia copper wire on surface or in recess for loop earthing as required. |
| 226 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.32A one-way double pole switch with indicator - 2 module |
| 227 | Supplying and fixing following rating, double pole, 415V, MCB,10kA as per IS/IEC 60898-1 2002, in the existing MCB DB complete with connections, testing and commissioning etc. as required. Legrand DX³ MCBs 4087 3737 or equivalent reputed make ABB, Schneider electric ,Havells . 40A |
| 228 | Supply and fixing of SMC JB with Krone connector for incoming Telephone Supply, Sintex make GSJB 1510 Model or equivalent reputed make and model as required |
| 229 | Indoor Industrial Tube Light Battens, with LED Tube, double side connection (inclusive), Philips TMC 501/Core Line Batten with 20W, 1200mm, Core Pro LED Tube/ Havells Regal Batten with 18/20W, 1200mm, Crystal Glass LED Tube or Equivalent model of Reputed make as required. |
| 230 | Bulk Head Luminaries IP65/66/67 IK09/10 with integrated LED source, Philips WT202 10W IP66, Havells Hexa 10W IP66/Equivalent model of Crompton. |
| 231 | 10.5 - 15W LED Bulb, Philips Core pro LED Bulb / Havells Adore LED Bulb make or Equivalent model of Reputed make as required. |
| 232 | Exhaust Fan, 230mm sweep Metallic DBB, Almonard/Havells/Crompton. |
| 233 | Ceiling Fan, Electrophoretic lacquered/Electroplated surface for anti-rusting, High speed fan with wider tip blade for effective air circulation, double ball bearing with Sweep 1200mm and High performance even at low voltage, Havells SS390 or Equivalent model of Almonard/Crompton. |
| 234 | Miscellaneous items for the purchase of screws, Bolts, Nuts & Washers, drill bits, cable ties, bends, tees, wire strippers, steel spring, cable glands, PVC junctions boxes etc., |
| 235 | Annexure-VI : Provision of UG Cables and Meter Boxes at Beypore Lighthouse |
| 236 | UG CABLE LAYING |
| 237 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Up to 35 sq.mm |
| 238 | Supplying and fixing cable route marker with 10cm X 10cm X 5mm thick G.I. plate with inscription there on, bolted /welded to 35mm X 35mm X 6mm angle iron, 60cm long and fixing the same in ground as required. (For all UG cables) |
| 239 | Supplying and fixing Energy meter box - Supply and fixing of SMC LT 3 - Phase KWh meter (Double Door), Sintex make, Model GSMB - 5628, Hinged Door type or equivalent make and model for accommodating Three Phase Energy Meter along with cut out, appropriate rating fuse, RCCB and MCB. with assorted accessories like brass/GI screws, nuts & bolts, fixing terminals, cable ties, sealant for water proofing, etc. (Right side of NA II Quarters (Near Main gate)) |
| 240 | Supply of UG Cable, 4Core x 16sq. mm, Armoured, All Copper Conductor - Solid / Stranded Non Compacted Circular, HR PVC/ XLPE Insulation, conforming to standards: as per IS 1554 Part-1&2 & IS 7098 Part-1&2, reputed make as required. (FromKSEB Meter to Power house Supply) |
| 241 | Supply of UG Cable, 4Core x 10sq. mm, Armoured, All Copper Conductor - Solid / Stranded Non Compacted Circular, HR PVC/ XLPE Insulation, conforming to standards: as per IS 1554 Part-1&2 & IS 7098 Part-1&2, reputed make as required. (From KSEB Meter to IQ) |
| 242 | Supply of UG Cable, 4Core x 6sq. mm, Armoured, All Copper Conductor - Solid / Stranded Non Compacted Circular, HR PVC/ XLPE Insulation, conforming to standards: as per IS 1554 Part-1&2 & IS 7098 Part-1&2, reputed make as required. (From Powerhouse LTDB to DB at Tower base for Tower Lighting and Automation) |
| 243 | Supply of UG Cable, 2Core x 4sq. mm, Armoured, All Copper Conductor - Solid / Stranded Non Compacted Circular, HR PVC/ XLPE Insulation, conforming to standards: as per IS 1554 Part-1&2 & IS 7098 Part-1&2, reputed make as required. (from Power house DB to Tower bottom DB and spare cableof Main Light) |
| 244 | Supply of UG Cable, 2Core x 2.5sq. mm Copper flexible conductor, Armoured, Flame Retardant type, Finolex / Havells/ATC make for Outgoing Mains to Streetlight from existing Streetlightand power house to security room |
| 245 | Supply of UG Cable, 2Core x 4sq. mm 1100V/ Copper conductor XLPE Armored UG cable of Finolex/ Havells laying from Power house to Pump room and IQ |
| 246 | Security amount, application charges, meter shifting and reinstallation charges to KSEB |
| 247 | Annexure-VII : Provision of Additional Streetlights & Gate Lights and Pump House at Beypore Lighthouse |
| 248 | Pump House Accessories |
| 249 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2Module (75mm * 75mm) |
| 250 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6A switch |
| 251 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16A switch |
| 252 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 6/16A socket outlet |
| 253 | Supplying and fixing following rating, double pole, 240 V, isolator in the commissioning etc. as required. existing MCB DB complete with connections, testing and and commissioning etc. as required.40A |
| 254 | Supplying and fixing 5A to 32A rating, 240/415V, 10kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 16A – 2Nos. |
| 255 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20/25mm |
| 256 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5sq. mm (Point wiring) |
| 257 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 258 | Earthing |
| 259 | Earthing with G.I. earth pipe 4.5m long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 260 | Providing and laying earth connection from earth electrode with 4.00mm (8SWG) dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 261 | Providing and fixing 4.00mm dia copper wire on surface or in recess for loop earthing as required. |
| 262 | Electrical Fittings |
| 263 | Supply of Outdoor LED Street Lighting Luminaries, 30W LED, Havells Endura City Lite/Luker LSTE30/Philips BRP042 26W or Crompton equivalent. |
| 264 | Supply of Outdoor LED Post Top Luminaries (Gate Lights), 15/18/20W LED, Havells Ruby (clear) or Coral (Opal) model or Philips equivalent model . |
| 265 | Fabrication of Street Light Poles and Accessories |
| 266 | 3” dia GI C Class Pipe, Tata/Jindal make (3m) length for Streetlight Poles threaded at both sides [one length pipe = 6m] |
| 267 | 8mm thick MS Plate of size 450x450mm (approx. 15Kg each) for Base plate of Streetlight Poles including gas cutting charges in required size |
| 268 | Fabrication of Streetlight Poles by welding MS base plate to non-threaded end of 3” GI pipe with 3” dia Hot dip galvanised MS plain Slip on flanges |
| 269 | 3” dia Hot dip galvanised MS plain Slip on flanges |
| 270 | 3”x 2” GI C Class Threaded Reducer Socket for Streetlight Poles |
| 271 | 2” dia GI C Class Pipe, Tata/Jindal/Reputed make (1m) length for Bend Pipes of Streetlight Poles [one length pipe = 6m] |
| 272 | Fabrication of Bend Pipe by threading using lathe work 2” dia GI pipe and pipe bending |
| 273 | SMC Pole mounted Junction Box with side hinged door, IP55, Sintex make GSJB 2014 |
| 274 | Fabrication of GI Half Clamps for the Sintex JBs inclusive of material and labour charges |
| 275 | 30A Bakelite/16A Porcelain Type Kit Kat Fuse Unit |
| 276 | 30A Bakelite Neutral Link |
| 277 | 30A 6way Closed Bakelite type Terminal Connector for each JB |
| 278 | 4way Earth Strip Terminal Connector |
| 279 | Supply of Un-armoured, 3Core x 1.5sq.mm, All Copper Conductor - Solid / Stranded Non Compacted Circular, HR PVC/ XLPE Insulation, conforming to standards: as per IS 1554 Part-1&2 & IS 7098 Part- 1&2,Finolex,Polycab,RRKabel. (For each Streetlight 5m x 2Nos.) |
| 280 | 3\"\" dia GI B Class Pipe, Tata/Jindal make for UG Cable crossover at pathways [one length pipe = 6m] |
| 281 | Foundation and base work for Streetlights |
| 282 | Earthwork Excavation (0.6 x 0.6 x 0.5m) for the foundation and 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) Concrete Work (0.6 x 0.6 x 0.5m) for the foundation with Post pipe placed in concrete inclusive of materials and Brick Work (0.3 x 0.3 x 0.45m) for post base and placing of pipes for cable entry and Plastering Work (4 x 0.3 x 0.45 + 0.3 x 0.3m) for post base and Painting Work (4 x 0.3 x 0.45 + 0.3 x 0.3m) for post base of Streetlight Posts(3m) |
| 283 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 32 A one-way double pole switch with indicator - 2 module |
| 284 | Single Phase Motor Starter Panel Box, Sintex make with complete accessories such as Voltmeter, Ammeter, provision for MCB, 16A SP MCB, Indication Lamp, Start & Stop panel buttons, etc., |
| 285 | DOL Motor Starter Panel Box, Sintex make with MF1 Single Phase DOL Starter, L & T make for 1HP Single Phase Pump. |
| 286 | Grey Plexo box & adaptor with PVC membrane - 2 row x 4 module IP 55 Plexo box with PVC membrane 6806 19 |
| 287 | Plexo3 boxes for DB, DX3,8 Module Conform to EN 60439-3, Weatherproof cabinets - IP 65 - IK 09 – Class II 6019 98 |
| 288 | Bulk Head Luminaries IP65/66/67 IK09/10 with integrated LED source, Philips WT202 10W IP66, Havells Hexa 10W IP66/Equivalent model of Crompton. |
| 289 | Miscellaneous items for the purchase of screws, Bolts, Nuts & Washers, drill bits, cable ties, bends, tees, wire strippers, steel spring, cable glands, PVC junction boxes etc., |
| 290 | Electrician (Labour) Charges for wiring of streelights, Gate Lights, garden lights, fitting luminaries and installation of 3HP, Motor |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender