Rail India Technical And Econimics Services Ltd-RITES has published Supply, Installation, Testing N Commissioning Of Indoor N Outdoor Gears Of Signalling N Telecommunication System Including Msdac For New Engine Escape Line At New Track Hopper, Sgtps, Mppgcl Birsinghpur. Submission Date for this Tender is 10-08-2022. Gear Product Tenders in Birsinghpur Madhya Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 28-Jul-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 04-08-2022 |
2 | 04-Aug-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 10-08-2022 |
Sl. No. | Item Description |
1 | Supply, Designing as per SIP & Supply of Multi Section Digital Axle Counter System (MSDAC) complete system as per RDSO Specification No .RDSO/SPN/176/2013 (Version 3 ) or latest consisting of:- 1) Central evaluator Unit 2) SM’s Reset Panel 3) Field unit along with web detector 4) Centralised High Voltage DC-DC convertors 5) Final track clearance relay for each section along with accessories equipped for detection points and track section. 6. Maintenance free earth for DP, Location boxes and evaluators as perOEM" requirement. |
2 | Tool Kit of MSDAC consisting of the following:- 1) Portable Data Analyser with Data Analysis software for report generation & Analysis-1 No. 2) Pure Sine wave Digital Multimeter Kusam – MECO Make Model No.859CF or equivalent – 1 No. 3) Dummy Wheel CEL makes – 1No. 4) Ring Spanner 17-19, 24-26 – 1 No. each 5) Open end Spanner 17-19, 24-26- 1 No. each 6) Socket Spanner with handle – 1 no. 7) Screw Driver No.902 – 1 No. 8) Screw Drive No.935 – 1 No. 9) Torque Wrench – 1 No. 10) Marking jig for drilling – 1 No. 11) Monitoring Unit- 1No |
3 | Supply and placing of second class bricks/Fly Ash brick size 225mm x 112mm x 75mm after laying of cable & refilling the trench by loose soil of 100mm to over cable. |
4 | Steel Appratus case Full, complete with `E" type lock & keys to drg. No.RITES/SIG/GEN/043-08. The E type lock shall have ward No. 32. |
5 | Key Lock "E" type with key Drg.No.SA-3376/M. Alt-2. Spec.No.IRS-S-30/64 different wards. Inspection by Owner"s reprsentative |
6 | Supply and Installation of Earth electrode assembly and concrete encloser with cover as per drg. No. RITES/SIG/GEN/013-98 and RITES/SIG/GEN/014-98 respectively. This includes providing connection to location box, signalunit, block instruments, cables etc. through GI wire 8 SWG suitably sparted on MS flats size 30 x 3 mm as per drg.No. RITES/SIG/GEN/015-98,RITES/SIG/GEN/016-98 & RITES/SIG/GEN/017-98. This includes: (i) Digingof pit in earth 3 m deep. (ii) Casting of cement concrete enclosure as per drg.No.RITES/SIG/GEN/014-98. (iii) Soil treatment as per standard practice involving supply & pouring of salt & charcoal. (iv) Connecting the equipment through earth lead wire & soldering. (v) Supply of cement,wiring material & soldering material. |
7 | Intallation, programming, Testing along Commissioningof Central Evaluators of MSDAC (includes & OEM certification),wiring from CT rack to the Central Evaluator, Installation and wiring the reset box and wiring the power supply to the Central Evaluator including the supply of shielded cable of required conductor size as applicable with other accessories, with their own material. Note: 1. Variation in detection points and/or track sections upto (+) 10% shall have no cost bearing.2. Installation of detection points and line side electronics box is not included in this item. 3. It also includes insertion of track relay contacts, wiring etc in the existing circuits |
8 | Installation, Testing & Commissioning of track device (double rail contact) including digging of trench, track crossing, laying of double walled antirodent corrugated pipe from track device to track side housing and making its terminations. Termination of 4Quad cable in track side electronic box. Fixing of deflector plates. (Double walled antirodent corrugated pipe made up of high density polyethylene of required diameter and all other accessories as per site requirement to be supplied by the firm & installation of EJB/ Track side electronic box inside the track side housing, including supply of wires and other accessories. |
9 | P-way work required for provision of Axle counter track detection devices to be fixed on rails including work involving re-spacing of sleepers, packing of sleepers etc |
10 | Indoor wiring & Outdoor wiring for axle counter relay, relay base. |
11 | Excavation of Trench, Depth 1.0 Mtr. & width 0.3 Mtr., in all soils including soft/hard rocky area and clearing of roots of trees, bushes, rocks etc., ballast and reconditioning etc., (including bailing out water and disposal of extra soil) including back filling with excavated earth and ramming of trenches after cable laying for the following depth and width as given below. The contractor has to conduct detailed site survey of the cable route.Prepare a plan to get approval of the owner"s authorised representative, putting white lime powder marking before excavation of earth under supervision of owner"s authorised representative.Whereverseveral cables of different categories have to be laid in the same path, all cables shall be separated with brick through out the length, instead of seperate trench in the concerned area. |
12 | Track crossing by horizontal boring method based on the drawing no.DRM/J/6735 dated 7-8-03 and as advised by the engineer at site. This includes the supply and insertion(pushing) of GI pipe (80mm) confirming to IS.1239 heavy class in the bore drilled with the coupler between two pipes. All the joints of casing pipes should be tight and leak proof. |
13 | Laying of signalling/Telecom cable in the trench/GI/RCC/DWC pipe as per cable route plan (Note: before issuing of cable to the contractor, the cable will be meggered jointly by the contractor and RITES Engineer at site and meggering certificate will be submitted in the office of the Engineer In Charge. Where cable is laid in HDPE pipes, no protective bricks are required. The same procedure will be adopted after the cable in laid at site without which no payment will be made to the contractor. If the insulation resistance after laying of cable is less than the reading previous meggering report. The contractor will have to repair or replace the defective cable at his own cost for which no charges will be paid . |
14 | Excavation of pit, casting of concrete foundationsfor full location box as perDrg.No.RITES/SIG/GEN /003-09This includes : Supply of Foundation Bolts and nuts, cement, sand, stone chip & mixing in the ratio 1:3:6. |
15 | Erection of full location box on foundation including fixing of `E"type lock & locking arrangement,wiring, testing & commissioning as per approved disposition plan& wiring diagram. Thisincludes - (i). Necessary arrangement of material& fixing of hylum sheet on 25 x 25 x 3 mm angle iron frame , resin bonded 10 mm thick grade P3 in standard size for shelves, boardfor fixing ARA terminal, disconnecting type terminal blocks, fuse blocks etc. (ii). Termination of cables with number embossed ferrules, bunching of cables with PVC tape including supply of ferrules, tape, cable fixing clamps etc.This also includes clamping of ables with contractors own material (iii). Filling up pit inside the location box by sand and plastering on the topof the sand. (iv).Fixing of terminals, 8 way strips, disconnecting type terminal blocks, fuse blocks, N.D. fuses, etc. as per approved wiring diagrams. |
16 | Painting of two coats ofenamelpaint over one coat ofRed oxide primer on the following items after scrapping and cleaning of the surface whereever necessary. Primer & paints both Asian make are to be supplied by contractor. Location boxes inside & outside surfaces with Aluminium paint. |
17 | (i) Full case |
18 | Alteration / Modification in the existing location boxes (full location box)/ Location Boxes (Half location box), fixing of equipments, cable insertion , termination ,wiring , testing & commissioning, two coat painting , lettering to suit the circuit as per approved wiring diagram. This includes filling with sand and plastering the same. |
19 | Supply of all type of indoor wires required for MSDAC, Pairing with old S&T system, Alteration in control panel, Relay rack, CT rack, Station master room and other all S&T syste, Interfacing with old MSDAC, and S&T system, SAT, correspondenca test,simulation,Installation and other S&T items,commissioning of the Yard. |