Supply And Installation Of Lab Equipments And Machinery In Govt. Hydro Engineering College, Bandla, Bilaspur, Himachal Pradesh , bilaspur-Himachal Pradesh

National Projects Construction Corporation Limited-NPCC has published Supply And Installation Of Lab Equipments And Machinery In Govt. Hydro Engineering College, Bandla, Bilaspur, Himachal Pradesh . Submission Date for this Tender is 04-08-2022. Laboratory Equipment Tenders in bilaspur Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33109614
Corrigendum : Supply And Installation Of Lab Equipments And Machinery In Govt. Hydro Engineering College, Bandla, Bilaspur, Himachal Pradesh
Open Tender
Indian
Himachal Pradesh
bilaspur
04-08-2022

Tender Details

Supply And Installation Of Lab Equipments And Machinery In Govt. Hydro Engineering College, Bandla, Bilaspur, Himachal Pradesh

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Jul-2022 Corrigendum - 1 Date 04-08-2022
2 30-Jul-2022 Corrigendum - 2 Technical Bid 04-08-2022

Key Value

Document Fees
INR 23600 /-
EMD
INR 1478000.0 /-
Tender Value
INR 7.39 Crore /-

BOQ Items

Name of Work: Supply and Installation of Lab Equipments and Machinery in Govt. Hydro Engineering College, Bandla, Bilaspur, Himachal Pradesh.
Sl. No. Item Description
1FLUID MECHANICS LAB Hydraulic Bench
21.Water circulation: Centrifugal pump with appropriate power(0.3-1 HP), Flow rate range:5-200 L/min, Storage Tank Capacity Min. 180L, Material GRP/FRP Corrosion resistant. 2.Sump Tank to collect water, Material: GRP/FRP Corrosion resistant, suitable capacity. 3.Measuring Tank fitted with piezometer tube, Discharge measurement:Separate system to measure large and small discharges,Material: GRP/FRP Corrosion resistant, Min. Capacity 40L. 4.With integrated flume of appropriate size for experiments with plate weirs and notches. Min. Size LxWxH: 530x150x180mm. 5.Leak proof Pipes and fittings:PVC/G.I/Gun metal(valves). 6.Top work surface compatible with various experimental units to be easily and safely positioned. 7.Proper arrangement to regulate the discharge. 8.Proper intake arrangement for water supply and suitable drainage system. 9.Electricals and service required: 1 Ph 220/230 volt, 50Hz/60Hz, AC supply, Control Panel : On / Off Switch, Mains Indicator etc. Mandatory Features: - Capable of handling/compatible with different experimental module setups: -Bernoulli"s Apparatus -Impact of jet Apparatus -Flow measurement Apparatus -Flow through Weir and Notches Apparatus -Orifice and mouthpiece Apparatus -Pipe friction Apparatus -Reynolds Apparatus Accessories: - -Electronic Stop Watch -Tool Kit -Instruction and Experimental Procedure Manual
3Bernoulli"s Apparatus
41.Compatible/ Mountable on Hydraulic bench firmly and securely without leaks. 2.Transparent Venturi nozzle with measuring points for measuring the static pressures. 3.Pitot tube for measuring Total pressure at various points. 4.Tube manometers for displaying the static pressures (atleast 6) and Tube manometer for displaying the total pressure. 5.Flow rate to be measured through Hydraulic Bench. 6.Robust construction on a strong sturdy frame. 7.Water supply and flow measurement using Hydraulic bench. Experimental Capability : To verify the Bernoulli’s Theorem experimentally. -Energy conversion in divergent/convergent pipe flow. -Static pressures and total pressure distribution along the Venturi nozzle. Accessories & Spares: Mounting Tools/Tool Kit,Standard Manometer hoes Pressure tapings. Instruction and Experimental Procedure Manual
5Impact of Jet Apparatus
61.Compatible/ Mountable on Hydraulic bench firmly and securely. 2.Transparent tank made of GRP. 3.Nozzle for generating the water jet with adjustable flow rate. 4.Different shaped vanes/deflectors: flat (90°), oblique surface(45°/135°,30°/60°), semi-circular surface(180°), conical surface. 5.Suitable arrangement for measurement of the jet forces.(weights etc.). 6.Flow rate to be measured through Hydraulic Bench. 6.Robust construction on a strong sturdy frame. Experimental Capability: -To measure the force developed by a jet of water impinging upon a stationary object and its comparison with the forces predicted by the momentum theory. -demonstration of principle of linear momentum. -Influence of flow rate and flow velocity. -Influence of different deflection angles. Accessories: -Instruction and Experimental Procedure Manual
7Flow Measurment Apparatus
81.Compatible/ Mountable on Hydraulic bench firmly and securely without leaks. 2.Measuring instruments: Orificemeter,Venturimeter and Rotameter,Material: Transparent for flow visualisation. 3.Tube manometers to determine the pressure distribution( atleast 5). 4.Total pressure measurement arrangement.(Pitot tube) 5.Flow rate to be measured through Hydraulic Bench. 6.Robust construction on a strong sturdy frame. 7.Water supply and flow measurement using Hydraulic bench. Experimental Capability: -To measure discharged using different measuring instruments: Venturimeter, Orificemeter, Rotameter. -Pressure measurement with Pitot tube -Comparison of different instruments for flow measurement -Determining the different flow coefficients -Calibration of different measuring instruments. Accessories: Mounting Tools/Tool Kit,Standard Manometer hoses Pressure tapings. Instruction and Experimental Procedure Manual
9Orifice and Mouthpiece Apparatus
101.Compatible/ Mountable on Hydraulic bench firmly and securely without leaks. 2.Transparent Supply tank, adjustable overflow and arrangement to read height of water, Material: GRP/FRP Corrosion resistant, Min. capacity 12L 3.Interchangeable orifice set with different diameters and cross sections.(Alteast 4, 2 having circular cross section and 2 having square cross section with different diameters/sides). 4.Point gauge with movable rods for ploting jet path of suitable scale 5.Panel arrangement for recording jet trajectory. 6.Robust construction on a strong sturdy frame. 7.Water supply and flow measurement using Hydraulic bench. Experimental Capability: -To determine the trajectory of the water jet at different outlet velocities -Visualisation ofthe trajectory of the outlet jet -Study of orifice with different diameters and contours -Determination of the coefficient of discharge, velocity and contraction. Accessories: -Instruction and Experimental Procedure Manual
11Pipe Friction apparatus
121.Compatible/ Mountable on Hydraulic bench firmly and securely. 2.Transparent,Supply constant head tank with overflow outlet, Material FRP/GRP corrosion resistant. 3.Differential manometer for pressure measurements of laminar flow upto 760mm of Hg. 4.Dial-gauge manometer for measurements of turbulent flow. 5.Test Pipe section of a circular pipe. 6.Water supply and flow measurement using Hydraulic bench. 7.Proper arrangement to regulate the discharge.(Through Valves) 8.Robust construction on a strong sturdy frame. Experimental Capability: -Measurements of the pressure loss in laminar flow -Measurements of the pressure loss in turbulent flow -Determining the critical Reynolds number -Determining the pipe friction factor -Comparing the actual pipe friction factor with the theoretical friction factor Accessories: -Instruction and Experimental Procedure Manual.
13Reynolds Apparatus
141.Compatible/ Mountable on Hydraulic bench firmly and securely without leaks. 2.SS/FRP/GRP supply tank for dye/ink of Min. 250 ml capacity 3.Water tank with flow stabilising arrangement, Min Capacity 2L 4.Proper arrangement to regulate the discharge.(Through Valves) 5.Glass section for visualisation of laminar flow and transition flow of appropriate length so as to stablise the flow. 6.Water supply and flow measurement using Hydraulic bench. 7.Robust construction on a strong sturdy frame. Experimental Capability: To determine the Reynold"s number and hence the type of flow either laminar or turbulent -Determining critical Reynolds Number. -Visualisation of laminar flow and transitioj from laminar to turbulent flow. Accessories: -Instruction and Experimental Procedure Manual
15Plate Wiers & Notches
161.Compatible/ Mountable on integrated flume provided on Hydraulic bench firmly and securely without leaks, Material: Corrosion resistant SS. 2.Rectangular wier & V Notch- 1Set each. 3.Head measurement using level gauge with scale 4.Moveable evel gauge to be positioned anywhere along the experimental flume. 5.Water supply and flow measurement using Hydraulic bench. Experimental Capability: -determination of discharge coefficient -comparison of measuring weirs -determining the discharge -comparison of theoretical and measured discharge Accessories: -Instruction and Experimental Procedure Manual
17Stability of Floating bodies Apparatus
181.FRP/GRP Corrosion resistant material tank for containing water for floating body/ship model with drainage. 2.Transparent floating body/Ship model provided with: i)Horizontally movable clamped weight for adjusting the heel ii)Vertically movable clamped weight for adjusting the centre of gravity iii)Clinometer with scale for displaying the heel 3.Apparatus should be compact with robust design. Experimental Capabilities: Study and determination of following:- -Buoyancy -centre of buoyancy -Centre of gravity - metacentre -stability Accessories: Weights/counter weights for clamping Instruction & Expreiment procedure manual
19Experimental Flume
201. Minimum length of the experimental flume 10 Meters. 2. Minimum Test Section length of the flume is 7.5 meters 3. The channel bed of the test section should be of at least 10 mm thick non-corrosive stainless steel. 4. There should be an electromagnetic flow meters discharge from the experimental section into the outlet/inlet tank. 5. The tanks should also be used as walkaway gallery at the side of the experimental section for the better observation and working on the test section. 6. Pressure chamber /seepage chamber under the test section the flume (it should be detachable type) with the length of 7.0 meters. Steel frame structure with 0.41mm dia mesh to support the sand bed should be provided. 7. Discharge measurement of seepage water measured by measuring tank. 8. There should be SS 304 grade rail on the both sides of the experimental section for the mounting of instrument trolley with measuring scale. 9. Instrument trolley should be movable in both X and Y direction over the rail. The trolley should have one stainless steel point gauges with least count of 0.1 mm. 10. Sediment trap should also be provided at the end of the test section to avoid the sediment from entering the pump. 11. Max. Flow rate of the pump should be 250 m3/h. 12. Flow straightener should be provided at upstream tank to ensure the smooth entry in the flume 13. All the tanks should be of non-corrosive material. 14. Height of the flume bed from the ground minimum 1.5 m 15. All Materials in contact with water should be corrosion resistant. 16. All pipes should be made of corrosion resistant Stainless steel grade 304/engineering plastic material. 17. Sliding Tail gate made of SS 304 (thickness 6 mm sheet) at the outlet at the flume for adjusting the depth of flow in the flume. 18. All storage tanks should be made from 1.5 mm thick SS 304 grade sheet with stiffener support. 19. Installation should be in supplier’s scope. 20. Control Panel should be provided on the platform which includes one AC Drives, single Phase protection relays, MCB and other safety features and manometer tubes should be fixed with it. 21. Staircase (rise = 0.25 m and tread = 0.25 m and 0.75 meter width) should be provided for climbing on platform. Also, there should railing over the platform to avoid falling from the platform. 22. Flume platform material: Heavy duty rectangular steel hollow section grade YST 310 as per IS 4923 painted with corrosion resistant galvanic paint. 23. The sump for storing the water should be under the platform, so that it doesn"t require any extra space. 24. Valves to be connected with pipes using good quality rubber gaskets. 25. Inclination should be -0.5 to 10 % with screw jack inclination system. Experimental Capabilities: -Basic principles of open-channel flow -uniform and non-uniform discharge -flow formulae -flow transition (hydraulic jump) -energy dissipation (hydraulic jump) -flow over control structures(weirs, notches etc.) -discharge under gates -flow-measuring flumes -local losses due to obstacles -transient flow: waves -sediment transport Accessories: -Uniform and non uniform discharge -Flow formulae (Critical, Supercritical, and Subcritical flows) -Flow transition (hydraulic jump) -Energy dissipation (hydraulic jump, stilling basin) -Flow over control structures: weirs (sharp-crested, broad-crested, ogee-crested) -Flow over control structures: discharge under gates -Flow-measuring flumes -Local losses due to obstacles -Sediment feeder Measuring Instruments: 1.Level gauge 2.Tube Manometers( Atleast 6 tubes). Technical Details: 1.Experimental section-Minimum Cross section : 600 X 750 mm, Minimum Length of test Section = 7.5 meters with side walls having transparent 10 mm thick toughened glass on either side of flume, Inclination : -0.5 to 10 % 2.Tanks-Material:- Stainless steel non corrosive, Capacity of downstream and upstream tanks: 1.5 times the channel capacity. 3.Discharge measurement at downstream (Main channel flow) Electromagnetic flow meter at the delivery pipe 4.Discharge measurement for seepage chamber (passed through channel bed) 5.Discharge measurement of seepage water measured by measuring tank with suitable scale. 6.Pump (s) 50 to 250 m3/h 7.Measuring devices of flow rate upto 250 m3/h
21Terms and Conditions: 1. The bidder should have supplied the experimental flume equipment to reputed govt. / semi Govt. institutes, preferably IIT’s, NIT’s. 2. The bidder should enclose at least two installation reports/PO of Fluid mechanics or Water Resource Lab equipment supplied toreputed govt. / semi Govt. institutes, preferably IIT’s, NIT’s. 3.Bidder should be either OEM or an Authorized dealer of the OEM. 4. Detailed drawings and design for validation of equipment with tender without which the bid will be rejected. 5. Institute can also call for technical presentation for quality assurance if required. 6. Bidder are required to submit original equipment data sheet of quoted equipment. Only Copy/Paste of tender specification will lead to rejection of bid. 7. Manufacturer should be ISO 9001:2008 certified manufacturer / supplier, who can ensure the supply of machines as per required testing standards of BS/DIS/ASTM standards and within the specified tolerance limits. Certification of incorporation from the manufacturer and ISO or International equivalent certification for the respective country. 8. The manufacturer shall clearly confirm that all the facilities exist with him, as applicable in his factory for inspection and testing. And these can be accessed by the purchaser or their representatives for inspection of technically qualified bidders before opening of commercial bids. 9. Bidders should provide details of service center and information on service support facilities that would be provided during and after the warranty period. Warranty Period of 2 years is desirable.
22CONCRETE TECHNOLOGY LAB Compaction Factor Test Apparatus
23Reference Standard Code- IS:1199:1959 Upper hopper: top internal dia-254mm bottom internal dia- 127mm Internal Height -279mm lower Hopper:top internal dia-229mm bottom internal dia- 127mm Internal Height -229mm Distance between bottom of upper and top of lower hopper - 203mm Distance between lower of bottom hopper and top of cylinder-203mm Mandatory Features: Equipment should consist of : a) two rigid conical hoppers and a cylinder mounted on metal frame. b) A circular metal plate is provided to cover the top of cylinder. c) A steel tamping rod of 1.6cm Diameter with a length of 61cm d) A trowel is used for mixing the concerete
24Ve-Bee Test Apparatus
25Ref. Standards - IS:10510, IS:1199, BS 1881 (Part 104), AASHTO T126, EN. 12350) The dimensions of various parts as mentioned shall conform to IS:1199 The Ve-Bee Consistometer should consist of: a) A vibrator table resting upon elastic supports b) A metal pot c) A sheet metal cone, open at both ends d) A standard iron rod e) suitable for operations on 415V, 3 phase, 50 Hz, AC Supply
26Flow Table
27Reference Standard Code- IS:1199:1959 Flow table apparatus consists of: a) Mould - The mould shall be made of a smooth metal casting in the form of the frustum of a cone with the following internal dimensions. A base 25 cm in diameter, upper surface 17 cm in diameter, and height 12 cm; the base and the top shall be open and at right angles to the axis of the cone. The mould shall be provided with handles. b) Flow table- the flow table shall confirm to IS:1199:1959. The integrally cast ribs should be designed for support and strength. The stand should be fabricated of cast iron and of sturdy construction. Holes for mounting on foundations should bedrilled in the base plate. Mode of Operation -Motorised; suitable for operation with 220 volts, 50 Hz, single phase, AC Supply.
28Rapid Chloride permeability Test
29Reference Standards- ASTM C 1202 The total Supply should include the following components: 1. Eight Cell RCPT apparatus with PC interface software 2. Acrylic Cells Machined as per ASTM C 1202 to hold the concrete- specimens of 100 mm diameter -8 sets 3. MS Moulds 100mm X 50mm height x 110 mm = 8nos 4. Measurement Channels 5. Short Circuit Protection System 6. Dataand timer Display on LCD Consumables: 4. NaOH salt -1000 gram 5. NaCl salt – 1000 gram Acrylic cell should consists of the followings: 1. Brass mess -88mm diameter 1no 2. Brass plate -88mm diameter 1no 3. Brass washer- 102 mm OD 88mm ID 1no 4. Rubber washer102mm OD 88 mm ID 1no The Equipment must have sample extracting and grinding unit. Mandatory Features: 1. Stand alone operation 2. Easy-to-assemble 3. Auto-sealable cells with rubber gasket and spacer (i.e. does not require caulking) 4.Accurate (±0.1 mA) 5. Flexible logging interval time (1 to 10 min) 6. Automatic temperature control system 7. Four measurement channels 8. User-friendly PC software9. Customizable setup 10. USB connection to computer11. Verification kit 12. RCPT device should comply and meet the specification of ASTM and AASHTO standard for sample cell 13. It should also come with CSA electrical safety certification mark for use in concrete laboratories. Note-The bidder or OEM (If OEM is directly participating in the tender) must have supplied this equipment in 2 or more government educational institutes and purchase order for the sameshall be attached. Below Listed Applications it should be able to perform- 1. Concrete’s ability to resist chloride ion penetration (ASTM C1202, AASHTO T277) 2. Bulk electrical conductivity of concrete (ASTM C1760) 3. Performance-based quality control of concrete 4.Estimation of chloride diffusion coefficient of concrete 5.Estimation of chloride migration coefficient of concrete 6.Service life design of concrete structures 7. Estimation of the remaining life of concrete structures
30Flexural Testing Machine
31Ref. Std. : IS: 516,9399:1979, BS: 1881 and ASTM C78. Flexure Testing Machines Salient Features : Light weight, rugged high strength frame • Double action hydraulic pump • Self-aligning roller assembly • Hydraulic jack provided with retraction spring • For testing beams of 100X100X500mm and 150X150X 700mm. -Real time DAQ and plotting. Provision to plote graph of load Vs time, Displacement Vs time and Load Vs diflection. etc Should be suitable for operation on 220V, 50Hz, Single Phase, AC supply The design should provide maximum rigidity throughout their working range. The load shouldbe applied by the downward movement of the piston. Aspacer should be provided for testing different sizes of beams. The load should be indicated on a calibrated bourdon tube type load gauge of range:0-100 kN x 0.5 kN The load gauge should be calibrated against the National Physical Laboratory/ National Council for Cement and Building Materials certified proving ring.The machine should able to acromodate test beam of 1.5 M.There should be a facility to direct save the report in Pdf form with Load/Time and Deflection Graph and other details after completion the test and entered the Beam broken length. Also the facility to take directly pdf report print out to any WiFi printer from Touch DisplayIt should be certified from in houseNABL. Mandatory Features: Automatic Flexure Testing Machine Testing Machine 200 kN Capacity,Servo Controlled close loop with touch panel.Details :- • Load Least Count 0.1 kN • As per IS: 14858(2000) and calibrated with an accuracy of ± 1% as per the requirement of 1828 (Class1) • Automatic Pace rate controlling with accuracy of 5% of set pace rate • Ref. Std. : IS:516, BS:1881 and ASTM C78. • Controllable rate of loading rate without shock and increasing continuously of 400 kg/min for the 15.0 cm specimens and at a rate of 180 kg/min for the 10.0 cm specimens as per IS 516 • Automatic Release the load after performed the Test through Software to using Solenoid valve • Large key catching display - 7” X 7” touch screen operation • Load v/s Time graph and deflection generating automatic on Touch Display directly in Pdf form with other details and PC as well. • Type of pumping: Electrical Servo Controlled close loop. • Ram travel – 50 mm or more • Facility to insert different size of the beam and length of the broken beam in the touch screen controller to see direct reading of Flexure Strength and Deflection • Facility to log all test reports data in Excel format like date-time, Test No, Pace Rate and Peak load, Deflection, Flexure Strength on Touch Display • Recording facility of upto 1000 test.
32Compression Testing Machine
33Loading range: 3000 kN (300 T) Least count: 0.1 kN Maximum clearance between platens: 370mm Maximum clearance between side platens: 340mm Platen size: 222 mm dia. Platen hardness: 612 HV (55 HRC) Piston Dia: 222.2 mmPiston stroke: 50mm Motor HP: 1 Motor make: GODREJ or Crompton Greaves or equivelente Power Requirement: 220 V/ 230 V, I Phase, 50 Hz, AC Supply Standards: IS: 516 & IS: 14858 . Data storage 2000 records. .Data Download thru RS232 in ASCII format. .User can set break point. .Store records can be viewed & print.. It should haveautomatic Pace rate control to set value & Pace rate can be changed during test also. . Machine can be operated with software through Capable of 2 way communication through FTP DC motor powered dual stage pump. Effective rapid approach for daylight closure Display of Load vs. Time graph in real time · Analysis & Processing Software – Continuous Voltage Transformer (CVT) ·In house NABL accredited calibration certificate. Mandatory Features: Pumping Unit – This has 0.5hp, 1Ph, 220V AC motor driven two-speed hydraulic pump & bonded strain gauge based pressure transducer. ·Fully auto controlled enhanced Digital Indicator (EDI) with touch screen then laptop,desktop 10.1 inch TFT LED backlit display Wi-Fi enabled for data transferConfigurable Engineering Unit for machine selection. .Should have facility to configure more than one Mode. Mode1-Compression / Mode2-Flexure / Mode3-Prism Testing / Mode4-Tensile Splitting strength. Brick platen needs to provided so that bricks and pavers can also be tested in it.
34Moulds for Concerete Blocks
35Reference Standard Code-10086:1982 Cube Size -150mm
36Reference Standard Code-10086:1982 Cube Size -50,100,225,300mm
37Reference Standard Code-10086:1982 Size - 150 mm diameter and 300 mm Height
38Reference Standard Code-10086:1982 Size - 100 mm x 100 mm x 500 mm
39Reference Standard Code-10086:1982 Size 150 x 150 x 700 mm
40Vicat Apparatus
41Reference Standard Code- IS-5513:1996 Mandatory Features: The Vicat mould shall be of truncated conical form with an internal diameter of 70± 5mm at the top, 80 ±5 mm at the bottom and a height 40 ±2 mm. The mould shall be adequately rigid and shall have a minimum wall thickness of 4 mm. Dimensions of the needles used for determining initial & final setting time and that of plunger to calculate consistency of cement shall conform to IS5513:1996. The needles shall be of hardened and tempered steel. Their hilts (fitting ends) shall be of brass.
42Le Chatelier"s apparatus
43Reference Standard Code-IS-5514:1996 Mandatory Features: The apparatus shall consist of a small split cylinder of spring brass or other suitable non-corrodible metal of0.5 mm thickness forming a mould 30 mm internal diameter and 30 mm high. The dimensions of split cylinder and pointer shall conform to IS:5514:1996. A pair of plane glass base and cover plates shall be provided for each mould. Each plate shall be larger than the mould,preferably of size 35 mm x 35 mm.The resilience of the mould shall be such that the action of a mass of 300g applied shall increase the distance between the indicator ends of the needle by 17.5mm The mould is supplied complete with two glass plates and lead weight. + 2.5mm without permanent deformation.
44Accelerated Curing Tank
45Reference Standard Code- IS-5513:1996 Provision of two removable racks allowing free circulation of water around each cube. The pump, drain valves and electrical equipment are housed in a compartment located at one end of the tank. · Floor model, heavy duty wheels for mobility. · Temperature Range: -0 to 100°C · Temp. Control: Digital Indicator cum controller · Resolution: 0.1°C Relative humidity-50 ± 10% · Control Accuracy: ± 2°C · Uniformity: ± 2°C · Refrigeration system with Branded ISI make compressors · Inner made of 304 grade stainless steel. · Outer made of Mild Steel with powder coated. · Double folded hinged Lid made of S.S.304 · Water circulating pump cum stirrer for uniform temperature. · Provided with water inlet and outlet valves. · with stand and heavy duty reinforced shelf for keeping cubes Suitable for operation on 440V, 50Hz, Three phase, AC supply. Mandatory Features: Heating and Cooling : For 12 cubes of 150 mm / 24 cubes of 70.6 mm size. Controlled from 10°C to 90°C ± 2°C curing temp, can be controlled at 27°C ± 2°C for normal curing or accelerated curing by boiling water method up to temperature range : 90 ± 2°C as per IS standard IS : 9013. Also it will have capacity for curing by warm water method at temperature 55 ± 2°C. The whole body of cube mould with the sample of concrete/cement mortar inside is to be immersed in the tank and the Tank is stout enough to bear heavy load on its platform. Tank will consist of a rectangular double walled metal cabinet, inner chamber made of 1mm thick stainless steel(S.S.304). Outer chamber made of 20 SWG Galvanized sheet - powder coated. 50 mm gap between the walls is filled up with special grade glass wool for purpose of insulation to avoid heat and cool losses. Specially designed L shaped High wattage heaters will be mounted in the chamber in such a way that, it facilitates easy replacement within 5 minutes by normal skilled person. It will have facility to circulate water inside the chamber by stirrer to maintain the uniform temperature of water. Inside the chamber, there will be a heavy gauge stainless steel perforated platform with ribs to with stand the heavy load of the cubes. It will also have a lid with lifting handle to cover the chamber.
46Slump Test Apparatus
47Reference Standard Code- IS : 9013 .Ref. Standards IS:7320 Mandatory Features: Appratus for slump test shall consist of : a) Mould - The mould for the test specimen shall be in the form of the frustum of a cone having bottom diameter -20cm ,top diameter-10cm & height-30cm. The mould shall be constructed of metal ( brass or aluminium shall not be used ) of at least 1.6 mm ( or 16 BG ) thickness and thetop and bottom shall be open and at right angles to the axis of the cone. The mould shall have a smooth internal surface. b)Tamping rod - The tamping rod shall be of steel or other suitable material, 16 mm in diameter, 0.6m long and rounded at one end.
48Rebound Hammer
49Reference Standard Code-13311 (part-2) Memory Instrument,Memory > 20,000 impacts Display memory - Memory of iOS or Android device. Mandatory Features: Rebound hammer shall produce following impact energy for different applications: a) Impact Energy for normal weight concrete-2.25 Nm b)light-weight concrete or small and impact sensitive parts of concrete - 0.75 Nm c) testing mass concrete in roads, airfields pavements and hydraulic structures -30Nm. Compressive Strength Range-10 to >70 N/mm2 . Display -Analog & backlit digital (100 x 100 pixels,graphic) Connections-Low energy Bluetooth, USB for charging and updates Measurements -Impact angle independent Displays the series on-screen as you work Series validity checked automatically Review an entire series Delete impacts. Battery- Standard AAA, alkaline or rechargeable. Battery Lifetime > 20,000 impacts between charges. Operating Temperature- 0° to 50°C
50Ultra sonic pulse velocity kit
51Reference Standard Code-13311 (part-1) Mandatory Features: The apparatus for ultrasonic pulse velocity measurement shall consist of: a) Electrical pulse generator b) Transducer - one pair c) Amplifier d) Electronic timing device. Range -0.1 – 7930 µs, Resolution - 0.1 – 7930 µs Display- colour display 700x450 pixels Touch screen with dual core processor Pulse Voltage UPV= 100 – 450 Vpp Measurement range upto 12 M depending on concrete quality. Transducers- 54KHz, 250KHz ,Bandwidth 25 – 450 kHz Receiver Gain(0 – 65dB) ,Memory Internal 6 GB Flash memory Regional Settings Metric and imperial units , Battery Lithium Polymer, 3.6 V, 14.0 Ah Battery Lifetime > 8h (in standard operating mode)Operating Temp -10°C – 50°C (Non-charging)Humidity < 95 % RH, non condensing, IP Classification IP54
52Specific Gravity Apparatus
53Reference Standard Code-2386(part-3) Buoyancy Balance—15 kg x 0.5g with NABL Certification Wire basket- 20cm dia ,20cm high Suitable for operationon 220V,50Hz,Singlephase, Ac supply Mandatory Features: The apparatus shall consist of the following conforming to IS: 2386(part3) a) Buoyancy Balance b)A wire basket of not more than 6.3 mm mesh or a perforated container of convenient size, preferably chromium plated and polished, with wire hangers not thicker than one millimetre for suspending it from the balance. c)A stout watertight container in which the basket may be freely suspended. d)Two dry soft absorbent cloths each not less than 75 x 45 cm. e)A shallow tray of area not less than 650 ems. f) An airtight container of capacity similar to that of the basket.
54Bulk Density and Void Ratio of Aggregates
55Reference Standard Code-IS:2386(part-3) The apparatus shall consist of : a)Balance - A balance sensitive to 0.5 percent of the weight of the sample to be weighed. b) Cylindrical Metal Measure-The measure shall preferably be machined to accurate internal dimensions and shall be provided with handles. It shall also be watertight, and of sufficient rigidity to retain its form under rough usage, and should be protected against corrosion. The measure shall be of 3, 15 or 30 litres capacity c)Tamping Rod- A straight metal tamping rod of cylindrical cross-section 16 mm in diameter and 60 cm longd) Bulk Density Measures, 10 and 20 Ltrs
56Carbonation Chamber
57* Triple walled construction with Outer Body made of Mild Steel painted with white Powder coated enamel & Inner Chamber made of Stainless Steel (304). The nuts, screws & hinges of the chamber will be of Steel. * The control panel of the Carbonation chamber will be separate and will be connected to the main body through connector. * Temp. Range is from 0 - 60 degC, controlled with an accuracy with accuracy of +/- 1 oC by Microprocessor * Temp. Range is from 0 - 60 degC, controlled with an accuracy with accuracy of +/- 1 oC by Microprocessor based Display Temp.Controller cum Indicator with pt-100 sensor. * Cooling through Hermetically sealed, high performance Cooling Compressor (ISI Marked, CFC Free) with its protective devices. For Heating, Fins Type Heating elements (ISI Marked) areplaced in the path of moving air duly insulated from sheet body. * Temperature, Humidity & CO2 Uniformity is maintained by couple of self cooling Motor with fans. * Separate Digital Humidity Controller cum Indicator is provided with electronic sensor. The Least count of the indicators will be at least 1 % RH. * Humidity Control at 40 - 95 % Rh with a sensitivity of +/- 3 %. ultrasonic Humidifiers which produces 1-5 micrometer of water droplets which is absorbed by the air quickly *Carbondioxide Concentration is controled by PID based Digital Controller with imported Asense (USA) sensor and Indicated in range of 0 - 20 % with an accuracy of +/- 1 %. * Power Supply 220/230 Volts A.C. 50 Hz.
58Universal Testing Machine
59Computerized Universal Testing Machine with automatic pace rate control- 1000 KN Supply and Installation of 1000KN capacity computerized Universal Testing Machine with automatic pace rate control. The equipment should have following specifications: The loading accuracy as high as +/- 1% of theindicating value. Equipment should be 6 pillar structure with hydraulic jaw grips, Strain measurement at variable speed to cover a wide range of materials adjustable by the manual control valve. High reading accuracy and rugged design of digital display. Simple control to facilitate easeof operation. Robust load frame with extremely rigid construction. Large effective clearance betweencolumns enable testing of standard specimen as well as structures. Motor driven threaded columns for UP/DOWN movement of lower crosshead for quick change over of specimen, grips and attachment. The Universal Testing Machine should have the resolution of 0.01KN and the maximum clearance for tensile test lies in the range of 50-650mm and maximum clearance for compression test lies in 0-600 mm range. The clearance between columns is 650mm and Ram stroke is 250mm.The straining/piston speed at no load is 0-50mm/min. For tension test the clamping jaws for round specimens are in 8-16mm,13-26mm,26-40mm specification and clamping jaws for flat specimens thickness is in 0-30mm range. The flat specimen width for tension test should be 70mm and for compression test the pair of compression plate’s diameter of circular platen should be 220mm.For the transverse test the width and diameter of rollers is 140mm and 50mm respectively. In the transverse test the maximum clearance between supports is 600mm and radius of punch tops comes in two different specifications i.e. in 16mm and 22mm.The crosshead geared motor is of 0.37kw and power pack motor is of 2.20kw. The machine should have microprocessor based electronic panel, Precision load cell for load measurement, Rotary encoder forcrosshead displacement/extension indication , LAN card for PC interface, Data entry for specimen dimension, serial number, gauge length. Unit selection for load, displacement. The Results include Load vs Displacement curve, Maximum displacement, UTS, % elongation , Young’s Modulus & Proof stress. The equipment should be provided with Robust Standalone and real time data acquisition system with Universal Ports, 18 Bit Resolution, more than 10 Analogue channels and 12 flexible digital channels, 8 Bi-directional channels for state & count input and state output. LCD Display, interface all types of sensors. The data logger should have Accuracy: 0.1% of full scale, ,Linearity 0.01 % and Easy Configurable Windows Based Software. The Equipment and Software should be provided with relevant attachments to conduct Tensile Test, Compression Test, Transverse test for flat specimen, Bend-Rebend Test, Shear Test and Extensometer. The extensometer test screen incorporates the result of the normal load VS Displacement Test as well as the Load Vs Extension online graphical view simultaneously, a unique facility on its own. The equipment to be provided with signal conditioner , strain gauges and temperature gauges. Electronic extensometer strain gauge type with 2.5mm extension and gauge length 50mm Bend Test attachment 180, flexural test attachment ,Shear Test attachment 6, 8, 12, 16 & 20mm dia Electronic extensometer strain gauge type with 2.5mm extension and gauge length 50mm Bend Test attachment 180, flexural test attachment ,Shear Test attachment 6, 8, 12, 16 & 20mm dia Shear test attachment 25, 30, 35 & 40 mm dia, Pair Threaded holdings heads 6, 8, 10, 12, 16, 18, 20mm, Pair of threaded holding heads 6mm,8mm,10mm,12mm,16mm,18mm,20mm Gripping device for threaded and shouldered specimens ,Pair of split ring for shouldered specimen 6,8,10,12,16,18,20mm(per set),The approximate weight for the 1000KN Universal Testing machine is 3500Kg. The machines should be calibrated in accordance with BS:1610 and IS standards. Universal Testing Machine comply with grade A of BS 1610:1964 and grade 1 of IS:1828-1991.An accuracy of +/- 1% is guaranteed from 20% of the load range selected to full load. Below 20% of the selected range the maximum permissible error is 0.2% of the full load reading. The Universal Testing Machine is suitable for operation on 440V, 50Hz ,three phase, AC supply. The equipment to be supplied with Laptop and Laser printer with latest configuration to support the equipment software. The bidder/OEM has to submit detailed data sheet of the equipment with all accessories as mentioned above and show the working of the equipment along with all attachments /accessories to the department during technical evaluation. The OEM should have experience in manufacturing similar equipments from for atleast 15 years and should have sold more than 5 Nos UTMs in last 3 years.
60Self Compacting Concrete
61Ref. Standards-ASTM C1621 1. L-Box The equipment consist of the following replaceable parts : • L-Box with three smooth bars equally spaced and a gate • Bucket capacity of 14 litre • Measuring scale 0-600mm • Spirit level • Stop watch with accuracy of0.1 second 2. U-Box The equipment consist of the following replaceable parts : • Bucket capacity of 14 litres • Measuring scale 0-600mm • Sprit level • Stopwatch with the accuracy 0.1 second 3. V-Funnel The equipment consist of the following replaceable parts : • Bucket capacity 14 litres. • Sprit level. • Stopwatch with accuracy 0.1 second for recording the flow time. 4. Flow Table for Self Compacting Concrete Ref. Standards - IS: 9103.1999 The equipment consist of the following replaceable parts : • Flow table • Slump cone • Wooden tamping bar Quantity - 1 each
62Grain Size Distribution Test
63Reference Standard Code-IS:2386(part-1) Specification:80mm, 63mm, 50mm, 40mm, 25mm, 20mm, 12.5mm, 10mm, 6.3mm IS sieve for grading of coarse aggregates. Specification: 600, 300, 150, 90, 75 (Micron), & 1.18, 2.36, 4.75, 10 (mm) for grading of fine aggregates Mandatory Features: Sieve Set for fine aggregates- Sieve size shall conform to IS:2386(part-1). Shape- round , Material- Brass
64Reference Standard Code-IS:2386(part-1) Specification:80mm, 63mm, 50mm, 40mm, 25mm, 20mm, 12.5mm, 10mm, 6.3mm IS sieve for grading of coarse aggregates. Specification: 600, 300, 150, 90, 75 (Micron), & 1.18, 2.36, 4.75, 10 (mm) for grading of fine aggregates Mandatory Features: Sieve Set for coarse aggregates- Sieve size shall conform to IS:2386(part-1). Shape- round , Material- Brass
65Laboratory Cement Autoclave
66Ref. Standard - IS:4031 (Part - 3) Special Features : Rust proof stainless steel pressure vessel & enclosure, Microprocessor based PID controller for accurately controlling the temperaturehence pressure Three fold safety mechanism for the equipment & the operator, Reliable silicon rubber lid sealing gasket, Very Compact Specification : Working Pressure - 21±1kg/cm2 at215° C Pressure Vessel- ID 150mm X Depth 500 mm Weight- 70Kg Heater - 2000Watts Supply - 220V, 50Hz, 1 phase Panel mounted PID controller with international safety certifications. The equipment consist of the following replaceable parts : Rubber Gasket, Viton 1 No., Pressure Gauge, 0-42kg/cm2, Safety Valve, Temperature Controller with Sensor Mandatory Features: The equipment shouldconsist of a Stainless Steel Pressure Vessel with insulated outer shell, fabricated out of high quality Stainless Steel Sheet. The pressure inside the vessel should be controlled through a micro processor based PID controller. The equipment should be supplied complete with spring loaded safety valve pressure gauge, PID controller with RTD for control of Heater unit.
67Wheel barrow
68Constructed in steel with rubber wheels mounted on bearings of varying capacities upto 100kg Tilt angle - 90 degrees
69Sieve Shaker
70Instrument should have a digital timer adjustable from 0-99 minutes. Instrument should produce gyratory motion and tapping motion as well. Mandatory Features: Motorised Shaker(Vertical as well as rotational shaking with a capacity of 8 sieves at a time, with speed control) of good Quality. Suitable for Operation on 220V, Single Phase, 50Hz, AC Supply and to be supplied with Adaptor to hold 8 sieves of 20cm dia.
71Measuring cylinders
72a) Material- Plastic Capacity-10ml,20ml,50ml,100ml,200ml,250ml,300ml,500ml,1000ml,2000ml 8 sets of each capacity should be provided
73b) Material-Borosillicate Glass Color-Transparent Capacity-10ml,20ml,50ml,100ml,200ml,250ml,300ml,500ml,1000ml,2000ml 6 sets of each capacity should be provided
74Weighing Balance
75200 Kg Capacity, Accuracy upto 10 gms Eqipments should be Digital Material- Stainless steel
7650 Kg Capacity, Accuracy upto 1 gm Eqipments should be Digital Material- Stainless steel
7710 Kg Capacity, Accuracy upto 0.1 gm Eqipments should be Digital Material- Stainless steel
78Miscellaneous Equipments
79Trowel of varying sizes Material- Stainless Steel Provied with sturdy handles
80Shovels of varying sizes Material- Stainless Steel Provied with sturdy handles
81Scoops of varying sizes Material- Stainless Steel Provied with sturdy handles
82Metal Trays of vaying sizes Material- Stainless Steel Provied with sturdy handles
83ENGINEERING SURVEYING LAB Total Station with Software
84Telescope: (i)Magnification- 30 x (ii)Image- Erect (iii) Field of view-1º 20’ Minimum (iv)Minimum focusing distance- 1 m or less (v)Reticle- 10 brightness levels adjustable (vi)Objective aperture- F 45 min Laser Pointer- Red Light, Coaxial Angle Measurement: (i) Standard deviation for Horizontal & Vertical angle- 1” or better (ii) Least Count- 0.1 sec or better Compensator: (a) Type - Electronic, Dual-axis or better (b) Compensation Range/Accuracy - ±3.0’/1” Distance Measurement: (i)Without Reflector - 1000 m or more (a) Single Round Prism: 3KM m or more (b) With Reflector sheet :1000 m or more in normal working condition (ii) Without Reflector Range : +/-(2 mm +2 ppm) (With Reflector) or better (iii) Accuracy : +/-(2mm + 2ppm) (Without Reflector) or better Plummet for Centering: (a) Centering device: Laser Plummet with accuracy of 1mm Measurement Time: (i) Standard Mode/Prism: 0.4/0.6/1.0 sec (Tracking/Fast/Fine) (ii) Reflectorless: 1.5÷5 sec Data Storage: Internal Memory : 8 GB or more for data storage (Internal Memory), External Memory 64 GB Compatible On Board Software Windows - Based Should have on board programs for orientation & Surveying, height transfer, Remote Height, Offset Stake out, area & volume calculation, area subdivision, visible layout, map, traverse and its adjustments, feature coding, should display the point, lines or polygon surveyed in the field, it should also provide direct output as dxf. File for the on board contours generated as it is and for other data collected. "(Including Software) Data downloading,processing software with all the survey capabilities (area calculation, volume calculation, contouring, level plotting,sectioning etc.) as basic features and also compatible with AUTO CAD, Google Earth, Data Communication via Bluetooth, pen drive, USB data cable as standard features." Battery: (a) Type : Lithium-ion batteries. b) Operating time (Angle + distance meas.): 12 hours or more Display & Keyboard :Display on both faces , should be colored sun readable display with touch screen & alphanumeric hard Keypad at least on both faces. Should be having at-least colored TFT LCD 320*240-pixel touch screen. Import and Export :Can Import and Export CSV, CAD, LandXML and Shapefile Environmental Specifications: (a) Working temperature Range : -10o C to + 50o C or better Guide light :To adjust the levels Weight :Less than or equal to 6.5 Kg. Interface :RS-232C/Standard USB/mini-USB/Bluetooth Sensor :Automatic Temperature and Pressure sensor should be present to auto apply corrections in distance measurement Dust/Water Rating: IP55 or better Bidder will also provide min. 2 weeks hands on training to the Institution at GHEC Bilaspur Campus Accessories with each TS: - (i) Telescopic Stand of extruded aluminium section with water proof cover, complete with all accessories, Supplied in PVC or wooden box. (ii) Telescopic Pole for prism = 1 Nos. (iii) Single prism with holder and target plate = 1 Nos. (iv) Internal battery = 2 Nos. (v) Dual Battery charger = 1 No. (vi) Tribrach without optical plummet = 1 Nos. and other required accessories.
85Handheld GPS Antenna / Receiver module
86Handheld should come with below listed specifications- Accuracy- It should come with sub-meter accuracy or better with GPS Satellites It should comply with floodlight satellite technology. Position Accuracy- <5.0M 50% CEP or better Multi Path Compensation- E GSM 900 Band Rejection. It should have NMEA 0183 and PMTK protocol support It should comply with E911, RoHS It should at-least 32 KHz clock output. It should come with Multi-tone active interference canceller (MTAIC). Update Rate- 1 to 10 Hz or better. Working Temperature- -40 ºC TO +85ºC Its Applicational Use shall cover below listed- a)Hydrographic Surveys b)Geodetic Network Densification c) Crustal Deformation Monitoring d)Civil Engineering field applications e)Cadastral Surveying f) Land Mapping. The field software must have: - 1. Facility to collect point, line, and area feature. 2. Every point collected must have coordinates. 3. Capability to adjust the data collection interval time. 4. Capability to take photographs attached with the coordinates of the feature collected. 5. Capability to add or create different features in the same file / job. 6. Capability to get attached with the GPS antenna module through Bluetooth. 7. Facility to export the data collected directly to google map. 8. Facility to show the map of data collection field on real time google map at background while collecting data. 9. Feature to display the accuracy of data collected and altitude of current position. 10. Facility to navigate the points collected in any feature from map of data collected, by long press on the point. 11. Facility to navigate through google maps, directly from point collected. 12. Facility to operate on Android platform. 13. Facility to show area of the polygon on screen after data collection. 14. Facility to share the file collected via email or wats app 15. Facility to select the type of survey – Real type or time interval based. 16. Facility to export the file to CSV, UTM, Google earth (KML) format, geocoordinate etc. Bidder will also provide hands on training to the Institution at GHEC Bilaspur Campus Display - Touch display, camera at least 50 MP, 6-inch screen size and 8 GB RAM or more
87Plane Table complete set with alidade ,U-fork, Trough compass ,hand level etc.
88750mm X 600 X 22 mm made of laminated board of hard wood, fitted with brass screws and brass washers, provided with metal head, metal stand and water proof cover,and complete with all accessories AS PER IS SPECIFICATION NO. IS-2539-1963, plane table board with tripod. These outfits can work complete with standard accessories namely Trough compass, telescopic alidade, Spirit level, Canvas cover, Plumbing Fork etc. all accesories packed in wooden or PVC box.
89Optical Square
90Consists of Brass / suitable metal hollow box having open face about 6 x 3 cms. and closed face about 2 x 3 cm. and deep about 4cm to 5cm. provided with a brass handle about 8cm. in length. Two mirrors fixed at an angle of 45 degree to the inclined sides of the box. Circular type made up of brass & fitted with double reflecting mirror right & left to 90, in case.
91Cross staff
92Size 4”, Open Type having four vanes at right angles, Complete in wooden box with metallic pole.
93Surveyer compass
94Made of Brass, Size 100mm dia. with metal circle graduated to full degree with two bubble and with bar needle fitted with real agate stone to give high accuracy precision bearing reading, Packed in PVC case, Supplied with Aluminum Tripod.
95Prismatic Compass
96Made of Brass, Size 100mm dia. Fitted with quality agate stone, Aluminum floating circle, graduated to read 30 minutes 10 (0.5 degree), Automatic lifter, Rreflecting mirror fitted on the sight vane, Slow motion type Prism reader fitted with colored glasses green and red, Packed in PVC case, Supplied with Aluminum Tripod, complete with all accessories.
97Theodolite
98Image: Erect, Length:178 mm, Magnification:30X , Effective Aperture: 38mm, Field of View: 2.6 M at 100M, Short Focus:1.5M ,Stadia Ratio: 1:100, Stadia Constant: 0 Resolving: 4”, Power Circle Diameter: Hz113mm, V100 mm, Graduation: 20’ Vernier Reading: 20”, Plate Level Sensitivity: 45” / 2mm, Vertical Circle Level: 1’ / 2mm, with metal tripod stand and proper covering packed in PVC Case.
99Measuring chain
10020 m and 30m chain corrosion resistant good quality material, with brass handels, brass links, brass tellies As per the IS 1492-1970
101Measuring Tape
10230 meter meassuring capacity Tape consists of 12 to 15 mm wide, strip of either Yarn coating or linen having very fine brass or copper or bronzewires Woven into it to prevent it from elongation and twisting Graduated in metric system. Eachmeter length is divided into decimeter and centimeters,WITH PLASTIC COVER.
103Ranging Rods
1043 m (collapsible) circular with 3 to 5 cm diameter made up of metal(NON CORROSIVE) conduit with conical metallic shoe fitted at bottom & fully painted with 20 cm long colour bands of either of the Black & White combination or Red & White, WITH COVER
105Pantograph
106Size 42”
107Ghat Tracer
108With pole and target.
109Tangent Clinometer
110Indian pattern
111Electronic Theodolite
112Telescope: Length:149mm Objective lens:45mm Magnification:30xPower Field of view:1°30" Resolving power:2"" Minimum focus:90cm Stadia ratio:100 Stadia constant:0 Sighting collimator:Double Electronic Angle Measurement Method:Absolute Reading Detecting:2 horizontal sides, 1 vertical sides Minimum reading:1"/5" arc seconds, 0.2mgon/1mgon mgon Accuracy:5 arc seconds, 71mm Diameter Circle LCD:7 segments Automatic Dual Axis Compensator Display: LCD, 8digits*2 Lines with Backlight on both sides Plummet Magnification 3x Min. Focus 0.3m Detachable Tribrach Operating Temperature: -20 to 50-degree C Rechaegeable Batteries: 2Nos. With charger Standard Accessories (Lens Cap, Plumb Bob) Tripod Stand of extruded aluminium section with water proof cover, complete with all accessories Including telescopic staff 4m & 4 in nos. of good quality, Supplied in PVC or wooden box.
113Levelling Staff
114Made of Aluminium body Telescopic in 3 PCS, 4 meter in length packed in canvas cover, graduated in meters, dm, cm, and mm with background and black strips. 5 mm thick with suitable locking arrangement Made of Aluminium body / Metalic Body folding in 2 PCS, 4 meter in length graduated in meters, dm, cm and mm. with white background and black strips. 5mm thick with suitable folding & locking arrangement. Improved soap with pattern is made of best quality well seasoned teak wood, Telescopic in three pieces, brass fitting and glued, thus greatly increasing its strength, stability and durability, Accurately machine divided and engraved to read 5 mm. painted and polished. Size 4 meters Long
115Digital Planimeter
116Display: Liquid Crystal, 8-digit Figures Measuring value: Maximum 10m2 (scale 1:1) "Measuring range: Maximum vertical width 325mm Horizontal roller rotating length: 30m" Accuracy: within +/- 0.2% (within +/- 2/1,000pulses) "Power: 1. Built-in rechargeable NiCd battery 2. AC Adapter 100V~240V (Auto Power-off provided)" Operating hour: Approx. 30 hours Accessories: Supplied with AC adapter & good quality PVC case "Features 1. Measurement by 6-digit pulse count 2. Easy conversion function of unit and scale 3. Hold memory function 4. Automatic shifting of unit to upper unit 5. Average value measurement"
117Umberella
118UV protective black canopy mounted on a mild steel frame with heavy duty ribs and shaft for added strength and durability in rough weather conditions Black Matte finish lacquer stickered handle for a comfortable hold; wrist strap for hands-free carrying Prints & Patterns : Plain Operation - Automatic Open & Manual Close . Frame - 3 Fold Size - Open Canopy Span (Diameter) - 37.5 Inches, Closed Length - 12 Inches Transparent storage sleeve included. Fabric - Superior Ponjee Black - Long Lasting Fabric UV Protective.
119TRANSPORTATION ENGINEERING LAB Los Angeles Abrasion Testing Machine
120The machine should comprises the following:- i) A hollow steel cylinder mounted on a sturdy frame on ball bearings capable of rotating about its axis in a horizontal position. ii) A detachable shelf fitted inside the cylinder at a distance of 1250 mm from the opening measured along the circumstance in the direction of rotation. iii) A motor with reduction gear which runs the drum at 30-33 rpm. iv) A Steel tray with handels650*500*50 mm. v) Digitalrevolution and time counter. vi) Abrasive charge consisting of 12 steel ball approximately 48 mm dia and each weighing between 390 and 445 g. The equipment suitable be suitable for operation on 220/440 v, 50 Hz, 3 phase supply. Equipment and accessories should be supplied as per IS 2386 Part IV. It Should come with a sound reduction casing preferably metal(with user friendly openable mechanism so that aggregates can be poured and extracted easily) Mandatory Features: IS sieve 1.7mm (Brass) with steeltray(2 in nos)600*500*50mm & 450*300*40mm
121Devel Attrition Tester
122The instrument will be used for determining the abrasion value of coarse aggregate. It should consists of the following:- i) Two hollow cast iron cylinders closed at one end andfitted with tightly fitting covers at the other and mounted on a shaft at an angle of 30o to the axis of the shaft. The cylinders size should be of 20 cm internal diameter and 34 cm deep. ii) A shaft adjusted to rotate at 30-33 rpm by reduction gear mechanism operated by a motor. iii) A revolution counter. Suitable for operation on 440 V, 50 Hz, 3 phase supply. Abrasive Charge - The abrasive charge shall consist of 6 cast iron spheres or steel spheres approximately 48 mm in diameter, each weighing between 390 and 445 g. An abrasive charge of 6 spheres weighing 2500 +/-10 g shall be used with each test sample. Equipment and accessories should be supplied as per IS 2386 Part IV. It Should come with a sound reduction casing preferably metal(with user friendly openable mechanism so that aggregates can be poured and extracted easily) Mandatory Features: IS sieve 1.7mm (Brass) with steeltray(2 in nos)600*500*50mm & 450*300*40mm
123Aggregate impact test Machine
1241) Equipment and accessories should be supplied as per IS 2386 Part IV 2) The machine shall have a metal base weighing between 22 and 30 kg with a plane lower surface of not less than 30 cm diameter . 3) A cylindrical steel cup of internal dimensions: Diameter 102 mm Depth 50 mm and not less than 6.3 mm thick with its inner surface case- hardened, that can be rigidly fastened at the centre of the base and easily removed for emptying. 4) A metal tup or hammer weighing 13.5 to 14.0 kg, the lower end of which shall be cylindrical in shape, 100.0 mm in diameter and 5 cm long, with a 2-mm chamfer at the lower edge, and case-hardened. The hammer shall slide freely between vertical guides so arranged that the lower (cylindrical) part of the hammer is above and concentric with the cup. 5) Means for raising the hammer and allowing it to fall freely between the vertical guides from a height of 38O +/- 5.0 mm on to the test sample in the cup, and means for adjusting the height of fall within 5 mm. 6) Means for supporting the hammer whilst fastening or removing the cup. (automatic blow counter) A cylindrical metal measure, tared to the nearest gram, of sufficient rigidity to retain its form under rough usage, and of the following internal dimensions : Diameter 75 mm Depth 50 mm,Tamping Rod-A straight metal tamping rod of circular cross-section 10 mm in diameter and 230 mm long, rounded at one end. Equipment should have automatic blow counter. Mandatory Features: IS sieves 12.5mm,10mm,2.36 mm (Brass), Enamel Trays (Min. 3)650*500*50mm,600*500*50mm,450*300*40mm
125Aggregate Crushing Machine
126Ref std for : IS 9377, IS 2386 i) A 15-cm diameter open-ended steel cylinder,with plunger and base-plate, of the general form dimension as per above metioned code. ii) A straight metal tamping rod of circular cross-section 16 mm in diameter and 45 to 60 cm long, rounded at one end.For measuring the sample, cylindrical metal measure of sufficient rigidity to retain its form under rough usage and of the following internal dimensions: Diameter 11.5 cm Height 18cm, (Equipment and accessories should be supplied as per IS 2386 Part IV) Mandatory Features: IS sieves 12.5mm,10mm,2.36 mm (Brass), Enamel Trays (Min. 3)650*500*50mm,600*500*50mm,450*300*40mm
127Specific gravity and water absorption of aggregates
128A balance of capacity about 3kg, to weigh accurate 0.5g, and of such a type and shape as to permit weighing of the sample container when suspended in water,A wire basket of not more than 6.3 mm mesh or a perforated container of convenient size with thin wire hangers for suspending it from the balance, container for filling water and suspending the basket, An air tight container of capacity similar to that of the basket,A shallow tray and two absorbent clothes, each not less than 75x45cm.A shallow tray of area not less than 650 & 325 sqcm. Glass VESSEL or Jar -A wide-mouthed glass vessel such as a jar of about 1.5 litres capacity, with. a flat ground lip and a plane ground disc of plate glass to cover it, giving a virtually watertight fit. Cloths- Two dry soft absorbent cloths, each not less than 75 x 45 cm. An airtight container of capacity similar to that of the basket. Bidder should also provide all the accessories to test aggregate lass than 10mm e.g. Pyconometer,vessel or Jar as per below mentioned code. (Equipment and accessories should be supplied as per IS 2386 Part III Mandatory Features: Enamel Trays (Min. 3)650*500*50mm,600*500*50mm,450*300*40mm
129Flakiness Gauge
130Metal Gauge as per IS : 2386 ( Part I ) Mandatory Features: Mild Steel Trays (Min. 3) 650*500*50mm,600*500*50mm,450*300*40mm
131Elongation Gauge
132Metal Gauge with Wooden base as per IS : 2386 ( Part I ) Mandatory Features: Mild steel Trays (Min. 3) 650*500*50mm,600*500*50mm,450*300*40mm
133Penetrometer
134Universal penertometerAs Per IS Standards - IS:1448 (Part 60), IS:1203, ASTM An accurately aluminium casting base has been designed to facilitate penetration tests to be made over a wide surface area of sample. Adjustable feet are provided in the base for levelling. Upright may be rotated to permit the testing of samples immersed in a thermostat bath. Each penetrometer is supplied with a plunger weighing 47.5 g for testing bituminous product, and one each of 50g and 100 g weights. The unit is compact with in-built timer to control duration of penetration preset in factory to 5 seconds. The instrument is provided levelling screws.a. Penetration Cone Ref. Standards IS:1448 (Part60),ASTM 0 937, IP 179, BS:4698,ASTM 0217, IP 50, ISO 2137 Mandatory Features: Electric Heaters (2 Nos.) ISI Marked and pans(for melting/heating) 2 ltr 2 in (Nos.), Digital Thermometer
135Ductility testing Machine
136It should comes with digital tempertaure and displacement indication.The apparatus consists of water bath with a thermostatic heater and a circulating pump to maintain uniform water temperature,One half of the briquette moulds is fixed in a fixed plate in the water bath, the other half of the briquette mould is fixed to a carrier which slides over a rotating threaded shaft with a clutch,The motor and gears to rotate the shaft are housed in a cabinet fixed above the other end of the both. A pointer fixed to the carrier moves over. a scale graduated from 0-110 cm x 1mm fixed on the bath with "0" (Zero) of the scale towards the fixed plates side,The rotating shaft has 2 speeds of travel for the bracket, 5 cm/min. and 1cm/min. selected by a clutch. Water bath inside is of Stainless steel with insulation and a water drain. A heater with thermostatic control is fitted. inside the water bath,Control switches for motor, stirrer, heater and indicator lamps are fitted to a control panel located at a convenient place on the water bath. Complete with three briquette moulds and one base plate. Working on 230 Volts, single phase, 50 cycles, AC.As per IS Standards IS:1208, ASTM D113, AASHTO T 51 (Bidder will also provide Hands on Training 2 Days at GHEC Bandla) Mandatory Features: Electric Heaters (2 Nos.) ISI Marked and pans(for melting/heating) 2 ltr 2 in (Nos.)
137Ring and Ball Apparatus
138Ring and Ball Apparatus semi autometic The apparatus should consists of two steel balls (9.5 mm dia), two tapered rings in brass, two ball centring guides, a ring holder and a bath 8.5 cm dia x 12 cm deep (Semi Automatic) (Bidder will also provide Hands on Training at GHEC Bandla)As per IP 58 and IS 1205 Mandatory Features: Spare centering guide and steel ball(Pack of 2 Nos).
139Specific Gravity Bottle
140Specific gravity bottle of 50 ml (High quality Borosilicate glass) capacity, with digital thermometer
141Digital Kinematic Viscometer
142Rotational viscometer:The Rotational viscometer performs ASTM D4402 & BIS 73 high temperature testing of asphalt binders. To determine the absolute viscosity of the bitumen. The viscometer features an electrically heated thermal chamber with an auto –tuned PID controller for precise regulation of asphalt temperatures up to 300°C. supplied complete with a C25 titanium bob & stainless steel cup. Parts- • Heater casing• Thermal cover (one half shown) • Cup • Guard • Connector cable • Heater Connector Rotational Speeds 10-900rpm Shear rate 1/s, s-25-1000 Torque Range 0-8NmShear stress Pa 10-1000 Viscosity Pas 0.05-250 The heater has temperature range Ambient above 250°C Measuring system DIN 53019 C25 (Bidder will also provide Hands on Training 2 Days at GHEC Bandla)
143Video Recording Camera
14424 - 105 mm Lens, 24 MP OR More Resolution,Auto ISO 100 - 12800, 100 - 25600 (in 1/3-stop or Whole Stop Increments), Expandable ISO L: 50, H1: 51200, H2: 102400,Li-ion Battery (Operation 10 Hrs or More),1/8000?sec or more shutter speed, Display 3.2?in,63-zone TTL Full-aperture Metering, Evaluative Metering, Partial Metering, Spot Metering, Center Weighted Average Metering,6 fps (High Speed), 3 fps (Low Speed), 3 fps (Silent Mode),Auto white balancing, Preset: Daylight, Shade, Cloudy, Tungsten Light, White Fluorescent Light, Flash, Custom, Color Temperature Setting, White Balance Correction,Audio / Video Output (NTSC, PAL),MOV, MPEG-4 AVC / H.264 video format,JPEG, RAW, RAW JPEG, DCF, Linear PCM Audio Format,2?years, Warranty and Free Transit Insurance.Li-ion Battery (Operation 10 Hrs or More) with external flash. Bidder will also provide Hands on training at GHEC Bilaspur.Should come with proper covering and mountable on tripod stand. Mandatory Features: Tripod Stand Adjustable to a height of 6 Ft.
145Camber Board
146Camber board should be 3 Meter long and made up of aluminiumsection of size 24 mm x 45 mm of thick gauge. Ratio: 2%,It should have highly sensitive magnetic spirit level and seat for it at centre
147Pensky Marten"s Appartus
148Cleveland : Ref. Standards- IS:1448 (Part69),ASTM D 92, IP36, BS:4689, ISO 2592 For determining the flash and fire points of petroleum products, except for fuel oil and those products which have open cup flash point below 79° C (175° F). Flash Point (Open) and Fire Point Cleveland: The equipment consist of the following replaceable parts : • Cleveland Flash Cup Brass, with an Insulated Handle. • Gas Test-Jet Assembly Correctly positioned and pivoted from a cast cup platform which is fixed to a heating bath.Energy Regulator, To regulate the rate of rise in temperature 220 V,50 Hz, Single Phase, AC Supply. Thermometer IP 28 C, Range: -6°C to +110°C, (Bidder will also provide Hands on Training 1 day at GHEC Bandla)
149Marshall Stability Test
150ASTM D 5581:2007, ASTM D 1559, ASTM D, with i5 Desktop computer, 2 GB Graphic card UPS, Laser colour printer 6927-06, BS598-107 and EN 12697-34 Load cell and LVDT. • The Automatic digital and analog Marshal testing apparatus should comply with ASTM D 5581:2007, ASTM D 1559, ASTM D 6927-06, BS598-107 and EN 12697-34., The test apparatus should have a load frame of 100 KN capacity, single speed, robust design for carrying out digital,standard, modified marshal stability test for 4” and 6” dia sample,Digital indicator for digital display of test results. • The Platen movement in the load frame should be easy and user friendly, The load frame should have vertical clearance more than 420 mm and maximum horizontal clearance more than 250 mm with platen diameter not more than 140 mm. The Equipment to be provided with Data Aquisition System and relevant software. It should be certified from in house NABL. Equipment should work both digitally and anlog.Capableto attach and remove digital and analog(mechanical) system or equivalent system with all necessory Accessories as per above mentioned code.Data Acquisition System Robust,stand alone,low power data logger with USB memory stick support and USB memory stick, Dual Channel isolation technology, min 15 analog(+/- 50v) sensorinputs(expandable upto 300 units),2 Serial ‘Smart Sensor’ ports, SDI-12 MULTIPLE NETWORKS,PROGRAMMABLE ANALOG OUTPUT,Modbus for SCADA Connection, eb & FTP CLIENT/SERVER,removeable screw terminals,interchannel islation upto 100 volts (Bidder will also provide Hands on Training for 2 days at GHEC Bandla) Mandatory Features: Accessories as per ASTM D 5581:2007, ASTM D 1559 for manual operation e.g. loading frame/loadingIntegral type Proving Ring capacity 3000 kgs, 3 dial gauge 0.01 x 25mm, 2 Thermometer 0 - 250ºC x 1ºC, with sample compactor and extractor for insitu and ex situ sample, as per above mentioned codes
151Benkelmen Beam
152Main Body: 55in (1,397mm) Length Probe Beam: 96in (2,438mm) Length, telescopes into case(wooden or PVC Box)for storage Open Length: 144in (3,658mm) with digital dial gauge 0.0001*25 mm travel accuracy Equipment should comply with IRC 81
153Digital Weighing Machine
154200 Kg Capacity,Accuracy upto 10 g with digital display,battery backup of 10 hrs or more, Electric operated with mild steel top as per BIS/ISO/ISI Standards
155Digital Weighing Machine
156100 Kg Capacity,Accuracy upto 1 g with digital display,,battery backup of 10 hrs or more, Electric operated with mild steel topas per BIS/ISO/ISI Standards
157Digital Weighing Machine
15810 Kg Capacity,Accuracy upto 0.1 g with digital display,battery backup of 10 hrs or more, Electric operated with mild steel top as per BIS/ISO/ISI Standards
159Trowel
160Stainless steel Blade 8-10 inch size 0.5 -1 mm thick,wooden handle
161Shovel
162Square head Stainless steel Blade 23.5- 25 inch size 2-3 mm thick,wooden handle
163Hot Air Electric Oven
164Temp. Range upto 250 Degree Celcius Through Microprocessor Controller or more, inside size >= 60*60*90cm or more,outer and inner body of Stainless steel, Min. 4 shelves, Thermostatically Controlled, Double walled chamber with inner wall of SS with perforation blower for uniform heat distribution all over the chamber SS Perforated trays5 in nos. for keeping samples Mandatory Features: Mild steel and Enamel Trays (3 Each) 650*500*50mm,600*500*50mm,450*300*40mm
165White Board
166Magnetic white board white (6ft * 4ft) with Magnetic Duster and Markers(4 Nos. Different Colours)
167CBR Test Apparatus
168Computerized California Bearing Ratio with Data Acquisition System and Software Standards as per IS:9669, IS:2720 (Part 16) Load Frame, 50 kN (5,000kgf), Capacity, Three Speed 1.5,1.25, 2.5 mm/min Mould - Gun Metal, 150m ID x 175 mm H. Perforated Base Plate - Gun Metal, for Mould. Extension Collar- Gun Metal 150 mm ID x 50 mm high. Penetration Piston 50 mm faces dia. Adjustable Bracket for Penetration Dial Gauge. Circular Metal Spacer Disc, with detachable handle, 148 mm dia. x 47.7 mm high. Annular Metal Weight 2.5 kg, 147 mm dia. with 53 mm dia. central hole. Slotted Metal Weight 2.5 kg, 147 mm dia. with 53 mm dia. slot. Perforated Plate 148 mm dia. with adjustable stem and lock nut. Metal Tripod for Dial Gauge. Cutting Collar Rammer 2.6 kg, 310 mm controlled drop Rammer 4.9 kg, 450 mm controlled drop. Electronic outfit for CBR Test, consists of: Digital Indicator, 1 No. owner: 230 ± 10% mains, 50 Hz, Single Phase, AC supply d) Parameter display: By a selector switch Load Cell, 1 No. Capacity: 50 KN (5000 kgf), Compression Type Maximum overload: 110% of the rated capacity Sensing: Strain Gauges in full bridge configuration Displacement Transducer, 1 No., Range: ±10 mm Data Acquisition System with Software,A38 Desktop Windows based i5, LaserJet Printer & UPS. With all accessories to collect and compact sample in-situ, ex situ as per above metioned IS Code.Data Acquisition System Robust,stand alone,low power data logger with USB memory stick support and USB memory stick, Dual Channel isolation technology, min 15 analog(+/- 50v) sensorinputs(expandable upto 300 units),2 Serial ‘Smart Sensor’ ports, SDI-12 MULTIPLE NETWORKS,PROGRAMMABLE ANALOG OUTPUT,Modbus for SCADA Connection, eb & FTP CLIENT/SERVER,removeable screw terminals,interchannel islation upto 100 volts.,(Bidder will also provide Hands on Training for 2 days at GHEC Bandla)
169Skid Resistance
170Equipment and accesories should be supplied as per Standard: IS: 2386 (Part 4) BS 812-114 , The apparatus should consists of a spring loaded rubber slider mounted on a pendulum arm. The arm should be adjusted vertically from a rigid support column andThe base has three adjustable feet so that the swing of the pendulum during the test moves through a truly circular path while operated directly on a road surface.
171Hydraulic Sample ejecter
172Should consists of:Hydraulic pump, Power pack with quick release couplings,Should have accessories/frames/moulds to ejectsoil (CBR Test) and Marshall Test bitumen sample from sampling tubes and mould. upto 60 cm (and as per lenghth of standard sample of Marshall Stability and CBR Test ) in length and 38 to 150 mm in diameter by a single operation. 60 cm piston stroke , 50kN pushing force, Adapter rings and ejector discs for 38, 50, 75, 100 & 150 mm dia sampling tubes or moulds, included, Sampling tube should beUnrelieved, 38 mm dia x 200 mm long.Ejector Assembly, Accesories and Moulds should comply toIS:9669, IS:2720 (Part 16),ASTM D 5581:2007 (Bidder will also provide Hands on Training for 2 days at GHEC Bandla)
173Universal Automatic Compactor
174It should havea new design motor driven mechanical compactor, useful for soil compaction moulds as per IS, BS &ASTM. Therammer shouldtravels across the mould and the table rotates the mould (Mild steel compaction mould)in equal steps on a stable base.The number of blows per layer can be setatthe beginning ofthe test. Drop -Adjustable as per IS, BS &ASTM Supplied with mild steel mould The equipment is suitable for operation on 220 V, 50 Hz, Single Phase, AC supply. Rammer - Circular faced adjustable weight as per IS, BS &ASTM,It should be suitable for Marshall and CBR Sample Preperation As perStandard IS: 2720 (Part 7 & 8), BS: 1377-4, ASTM: D698 & D1557(Bidder will also provide Hands on Training for 2 days at GHEC Bandla)
175Buckets
1761. Galvanised Metallic Unit weight buckets to measure the construction material(sand, stone, aggregates) Volume: 1L,2L,3L,5L, 7L, 10L,20L,30L,50L 2. Heavy Duty Mason Buckets of Galvanised Steel Volume: 10L, 12 L, 15 L, 20L,30L (Sets Each)
177Metal Brushes
178Metal brushes of different shapes and sizes for cleaning the moulds, trays etc. (sets)
179Vibrating Tables
180Motorised, Material : Steel, Dimensions : 600*600*100mm Automatic, Suitab;e for Single Phase 50 Hz, AC Supply
181Tamping rods
182Refernce Standard Code: IS 1199(1959) The tamping rod shall be of steel or other suitable material, 16 mm in diameter, 0.6 m long and rourded at one end.
183Concrete Vibrator
184Portable Electric concrete needle/shaft vibrators Length-6m
185Concrete Mixer
186Refernce Standard Code: BS 1881 Part 125:1986 Pan Type , Motorised Capacity - 200Kg/ batch
187Sieve Set
188IS Sieves (Brass) of High Quality Ranging from 20 micron meter to 80 mm with a Mechanical Shaker(Vertical as well as rotational shaking with a capacity of 7 sieves at a time, with speed control) of good quality, Suitable for Operation on 220V, Single Phase, 50Hz, AC Supply.
189ENVIRONMENTAL ENGINEERING LAB Digital Hot air Oven
190Temperature range Ambient +10°C to 250°C Temperature accuracy ±0.5°C or better Temperature sensor RTD PT100 Temperature controller PID temprature controller Construction Double walled Inner chamber Stainless steel Size-605*455*910mm (capacity 250 Ltrs.)Exterior Powder coated GI sheet Insulation Fiber glass Wool Shelves Chrome plated wire mesh cable trays (removable) No. of Shelves-2 Door with Synthetic rubber gasket Air circulation Motor driven blower assembly Vent port 2 fume vent ports (adjustable) Power supply 220 Volts / 50 Hz The supplier shouldbe ISO certified for quality standards.
191Double distillation unit
192• Double Distillation Units manufactured with Borosilicate glass. • Demountable Boiler Panel. • Power Consumption: 1.5x2=3.0 kW, 2.2x4 = 8.8 kW, 2.2x2 = 4.4 kW • Temperature: Distillate Temp: 65-75°C Capacity:1.5Ltr./hrs. The supplier should be ISO certified for quality standards.
193Muffle furnance
194Chamber size (DxWxH) 12x8x8" Usable chamber space (DxWxH)10x7x7.5", 10 L approx with swing aside door at the front. Furnace construction (i) Double shell steel case with cooling fan to keep outside case cool (ii) High purity alumina fiber insulation for max. energy saving Heating element The chamber section should be heated by six to eight Super Kanthal Molybdenum disilicide heating elements (Super 1800 grade MoSi2) suspended in a chamber made of high temperature refractory fiber lined with a combination of ceramic fibre blankets. Temperature Control The temperature controller should be a PID automatic control power control and programmable with necessary safety features. Heating Rate The furnace should be of fast heating type with the maximum attainable temperature should reach as a ramp function in less than one hour. Cooling Fan/ Attached with Furnace, Provided inside the control unit to protect Costly component Max vs constant working temperature- 1400°C (2552°F) / 1300°C (2372°F)Min. working temperature- Ambient Max heating / cooling rate- < 15°C (59°F) / min Temperature precision- +/- 1? Electrical requirements- 110-240VAC, 50/60Hz, single phaseUnit dimensions (LxWxH)-22x25x34"Instrument must be ISO certified.
195Precision Balance
196Capacity=220g Readability=0.0001g Reproducibility=0.0001g Linearity =0.0003g PanSize=90mm Display=LCD Calibration=Automatic Internal Tare Range=Full The supplier should be ISO certified for quality standards.
197Research Grade DO/BOD Meter DO/BOD
198Range=0 to 90ppm(mg/L);0.0 to 600.0% Saturation Resolution=0.01ppm;0.1% saturation Accuracy=±1.5% of reading Calibration=Automatic using single or two point calibration. Barometric Pressure Range=Range= 450 to 850 mm Hg Resolution=1mm of Hg Accuracy=±3mm of Hg Temperature Range=-20 to 120°c Resolution=0.1°c Accuracy=±0.2°c Measurement Mode Direct DO;BOD;OUR;SOUR Temp. Compensation=0.0 to 50°c Salinity Compensation=0 to 40ppt PC Connection=opto isolated USB Calibration Standards must be included..The supplier should be ISO certified for quality standards.
199BOD incubator
200• Triple walled, outer made of MS duly powder coated and inner chamber of AL/SS • 3" Gap between outer and inner chamber should be insulated with thick blanket of high efficiency mineral wool • Temp. Range 5° to 50°C ± 0.5°C controlled with Digital Temperature controller • Should be Provided with 2 Nos. circulation fans for uniform temp. • A built in CFC Refrigeration unit with good quality compressor & condensing unit provides temp. below ambient temperature • Size 4 cft. • Electrically operated on 220V/AC. Single Phase
201pH/EC/TDS and Temp. Meter
202pH/EC/TDS and Temp. Meter (a) For pH determination: Range = -2 to 16.00 pH Resolution= 0.01pH Accuracy = ±0.01pH pH Calibration= Automatic Five point Calibration Temperature Compensation=Manual and Automatic from -20 to 120°C (b) For Conductivity: Range=0 to 500 ms/cm Resolution=0.01µs/cm; 0.1µs/cm; 0.01ms/cm,0.1ms/cm Accuracy=±1% of reading Calibration=one point slope calibration Note: (a) Calibration Standards must be included.
203Digital Turbidity meter
204FNU Mode Range=0.00 to 1000 FNU Resolution=0.01 Accuracy= ±2% of Reading plus stray light 1 FAU Mode Range= 10 to 4000 FAU Resolution=0.01 Accuracy= ±10% of Reading NTU Ratio mode Range=0.00 to 4000NTU Resolution=0.01 Accuracy= ±2% of Reading plus stray light ±5% of reading above 1000NTU NTU Non Ratio Mode Range =0.01 to 1000NTU Resolution= 0.01 Accuracy= ±2% of Reading plus stray light Range Selection Automatic Repeatability ±2% of Reading plus stray light Stray Light 0.1NTU Light Detector Silicon Potocell Light Source IR LED Method ISO7027 method MeasuringMode-Normal,Average,continuos Calibration Two ,three, four or Five point Calibration Log Memory 200 records Serial Interface USB Calibration Standards must be included.
205U V spectro photometer
206Wavelength Range nearly 190-1100 nm (Scan Range) Optics - Monochromator with grating and stepmotor / reference beam Lamp- Xenon Flash Lamp (500 million flashes possible) with five years warranty Display- Backlit 7” colour display for extensive graphical evaluation, Operation- Membrane Keyboard (Alpha Numeric Membrane Keypad), Stray Light- < 0.05 % Transmission at 340 and 408 nm Bandwidth- 4nm Measurement- concentration, single and multi-wavelength measurement of absorbance and % transmission, kinetics, spectra Turbidity correction- The instrument shoud have automatic turbidity correction in Conc. Mode Scan speed- 700–2000 nm/min, Scans in 1, 2, 5, 10 nm steps of wavelength range Wavelength accuracy/Reproducibility- ± 1 nm / < 0.5 nm Photometric accuracy/Reproducibility- – 0.003 E for E < 0.600; 0.5 % of values for 0.600 < E < 2.000Cuvette- 16 mm round, 10 mm, 20 mm, 50 mm rectangular with automatic detection w/o adapter additionl 13mm and 24 mm cells could be used Bar code-Automatic method recognition including measurement range for all cuvettes, external bar code reader could be added , Data storage- 5000 measurement values, spectra and kinetics approx. 40 MB => 500 spectra (300–900 nm) and 400 kinetics with 150 measurement values Methods and profiles- > 150 pre-programmed methods, 100 user-defined methods, comprehensive programming options , Instrument should be preprogrammed for Iron analysis at 510 nm with 1,10 Phenanthroline method as per APHA, Instrument should be preprogmmed for DO atleast upto 10ppb-800ppb. Sulphate upto 1000 ppm, Manganese, Chlorine, COD from 0 - 15000 ppm and other water analysis parameters Interface/update-1 USB-A, 1 USB-B, 1 Ethernet(LIMS Connectivity ASCII,.CSV-files),External Barcode Reader and Scanner/ Update via Internet and USB stick IP Class- IP 30 including drainage in optical compartment Temperature Range-Operation: +10 °C to +35 °C, Storage: –25 °C Certification- Instrument must have ISO certification for production for water testing kits and instruments from manufacturer. Calibration standards andReagent for 100 samples must be included.
207Jar test appratus
208The equipment should have following specifications: •16 x 2 LCD Display •RPM Mode •RPM & TIMER Mode •Soft Touch Keypad •Specially designed for use in water treatment plant as jar test apparatus •Should be able to provides identical test conditions for all samples •In which Stirring shaft can be removed without disturbing other stirrers •Illuminator base should be made of acrylic sheet which provides diffused cold light through floc. Samples •RPM: Variable from 5 to 150 rpm with accuracy of +/- 1 rpm •Timer: 100 Hrs • Display: 16 x 2 LCD • Jar: for 1000 ml x 6 nos • Paddles: stirring paddles made of s. S. - 6 nos • Illumination: fluorescent white light Instrument must be ISO certified.
209COD And Multiparameter Photometer for Chlorine free or Residual.
210COD Low Range Range=0to 150mg/L Resolution=1mg/l Accuracy=±5mg/l or ±5% of reading COD Medium Range Range=0to 1500mg/L Resolution=1mg/l Accuracy=±15mg/l or ±4% of reading COD High Range Range=0to 15000mg/L Resolution=10mg/l Accuracy=±150mg/l or ±3% of reading Chlorine Free Range= 0 to 5.00 mg/L Resolution=0.01 mg/l Accuracy=±0.03mg/l or ±4% of reading Method = DPD Total Chlorine Range= 0 to 5.00 mg/L Resolution=0.01 mg/l Accuracy=±0.03mg/l or ±4% of reading Method = DPD Light Source Tungsten Lamp with narrow band filter Light Detector Silicon Photocell Data logging Upto 200 Samples PC Connectivity USB NIST certified COD Reagent For 100 samples Instrument must be ISO certified.
211C.O.D. Test Tube Heater
212Temperature of reaction: The test tube heater should have two predefined temperature profiles at 105°C or 150°C that can be selected at the press of button. Temperature stability ±0.5°c Temperature Range -10°c to 160°c Accuracy ±2°c Capacity 25 vials or more one receptacle for a stainless steel reference thermometer Block aluminium Display The block temperature is continuously display on LCD. Overheating Prevention The heater block must contain a thermal fuse that prevents overheating.
213Autoclave
214Vertical with 35 liter capacity Temperature Range 120 Deg C approx. at 15 20PSI approx. Pressure Range 5 to 20PSI (+/- 3 PSI) Power Consumption 220 /230 V AC Phase Single Phase Frequency 50 Hz Timer 0-60minute Control Panel Temp. / Pressure Indicator, Pressure Switch,Instrument must be ISO certified.
215Leminar Flow
216Laminar Cabinets Inner Chamber & Outer Chamber made of stainless steel high efficiencyparticular air filters, to achieve the air purification upto 0.3 Microns in Working area. Working area 4 ft x 2 ft x 2 ft (approx.) Blower with ¼ HP Motor, with RPM 1200 to 1400. Should be Fitted with UV Germicidal lamp for sterilization. Should be Fitted with Acrylic Front Door sliding type Should be Fitted with Manometer for Measurment of HEPA Filters Choking system. Should be Fitted with Cock for Gas Connection. Working area of Laminar Airflow Cabinets illuminated by fluorescent light operated with AC Power supply 0f 230V. Single Phase 50HzInstrument must be ISO certified.
217Centrifugal machine
218Tube Capacity :Size 5 – 15 ml No. (4-6) Should have a digital timer Body should be made of strong fabricated & corroision resistent steel Control panel – for start/stop switch, dynamic brakes, step less speed regulator with zero start switch & speed indicator with timer and protective fuses. Maintenance-free brushless drive motor with exact speed preselection and display. Speed range 100 to 6000 rpm and above, accuracy 1 rpm. Power input to be 220-240VAC, 50Hz as appropriate fitted with Indian plug The supplier should be ISO certified for quality standards.
219Digital Magnetic stirrer with Hot Plate
220Stirring places 1 Max. stirring capacity 2 L Rotational sp. range 0 to 1250 rpm Temperature range +20 to +300 °C Timer range 0 to 999 min Power supply 220 V / 50 Hz Operating conditions +15 to +50 °C / <80 % RH Plate dimensions 135 x 135 mm (Approx.) Dimensions 230 x 180 x 120 mm (Approx.) Weight 2.2 kg (Approx.) Magnetic beads for stirring
221Digital Orbital Shaker
222Dimension( WxDxH) - 370x420x100 mm Shaking speed range-100-500rpm Maximum load capacity- 7.5 Kg with platform orbital diameter-10mmTiming setting range- 1min- 20 hrs.Permissible ambient temperature and humidity- 5-40?, 80% RHDouble LCDs dor Independent display of time and speed Brushless DC motor ensures maintenance-free, reliable and quiet operation
223Labrotary thermometer
224Temperature Range -20-150C Type Glass Thermometer Accuracy 1C
225Double Door Refrigerator
226Temperature Range(?) 3~16? Capacity- net total-above 300litreand gross total above 400 litre Net width- 675 mm Net case height with hinge- 1785 mm Net depth with door handle-668mm Net weight upto 70 kg Digital inverter compressor Twin cooling plus
227Borosilicate Glassware and other accessories
228Imhoff cone with stand:1000 ml
229Beakers:
230a) 250 ml
231b) 500ml
232c) 1Litre
233d) 2 Litre
234Volumetric Flask:1000 ml
235Conical/Erlenmeyer flask:
236a) 250 ml
237b) 500ml
238BOD bottles:300ml
239Round bottom flask:500 ml
240Glass vaccum Buchner Funnel:200 ml
241Funnels:
242a) 50mm
243b) 80mm
244c) 90mm
245d) 2 Litre
246Burrets :100 ml
247Burret stand
248Storage Tube:15 ml
249Test tube :20 ml
250Dropper:20 ml
251Graduated Cylinder:
252a) 50ml
253b) 500 ml
254c) 1 Litre
255d) 2 Litre
256Graduated Pipette with suction bulb:10 ml
257Desiccator:400mm
258Glass Slide:standard lab size
259Glass Stirring Rod:12 inch length
260Durham Tube:1ml (7*35*0.5mm)
261Disposable Petri dish:90 mm
262Glazed porcelain evaporation dish:120 ml
263Plastic Wash bottles:500 ml
264Spetulas:standard lab size
265Tongs:satndard lab size stainless steel tongs
266Cleaning Brush:overall length 330 mm
267Test tube rack:Capacity- 20 test tube
268Bucket:20 Litre
269Plastic water Mug:1L
270Plastic Bottles:1L
271Ice Box:25 L
272Surgical Mask:100 mask (box)
273Gloves:size -medium (100 pairs) (box)
274Aluminium foil:above 70m
275Whatman Filter paper:2 micron circluar with diameter 125mm (1 pack of 100 )
276Aquarium Air Pump with silicone tube:120 litre/min
277Vacuum pump for suction:maximum peak flow rate- >2 L/min
278Heat resistant safety Gloves: Reusable, temperature- 900? (pairs)
279GEOTECHNICAL ENGINEERING LAB Core cutter apparatus
280[Ref. Standard IS: 2720 (PART-29)-1975] 1. Cylindrical Core-Cutter - of seamless steel tube, 130 mm long and 10 cm internal diameter, with a wall thickness of 3 mm, bevelled at one end. 2. Steel Dolley – 2.5 cm high and 10 cm internal diameter with a wall thickness of 7"5 mm with a lip to enable it to be fitted on top of the core-cutter. 3. Steel Rammer - With solid mild steel foot 140 mm diameter and 75 mm height with a concentrically screwed 25 mm diameter solid mild steel staff. The overall length of the rammer including the foot as well as the staff should be approximately 900 mm. The rammer ( foot and staff together) should weigh approximately 9 kg.
281Sand replacement apparatus
282[Ref. Standard IS:2720 (Part 28) -1974] 1. Cylindrical Steel Core-Cutter of steel, 127.4 mm long and 100 mm ID with a wall thickness of 3mm bevelled at one end. 2. Sand Pouring Cylinder fitted with Conical Funnel and Shutter, capacity 3 litre 1 No. 3. Metal Tray size 30 x 30 x 4 cm, with 10 cm central hole 1 No. 4. Tools for excavating holes: Bent Spoon, dribber 5. Cylindrical calibrating container with an internal diameter of 100 mm/200 mm and an internal depth of 150 mm/250 mm fitted with a flange 50 mm/75 mm wide and about 5 mm surrounding the open end. 6. Glass or Perspex plate, 450 mm square and 9 mm thick.
283Infra-Red Moisture Meter
284[Ref. Standard IS: 2720 (PART-2)-1973] The instrument should be provided with an indicator lamp, which glows when the unit is switched on. The torsion balance should have a built-in magnetic damper or reduce pan vibrations that enables quick weighing. The balance scale (drum) should be divided in terms of moisture percentage on wet weight basis, which are read directly from it. Graduations are from 0 to100% in 0.2 % divisions, but readings may be estimated to 0.1 % moisture content. Suitable for operation on 220 V, 50 Hz, Single phase, AC Supply. • Capacity - 5g approx. • Sensitivity – 10 mg approx. • Range - 0 to 100% moisture content on wet weight basis. • Reading accuracy - ± 0.20% • Probable error -± 0.25% in the lower range upto compared to 25% and ± 1 % for moisture contents above 50%
285Electric Hot Air Oven
286[Ref. Standard IS: 2720 (PART-2)-1973] 1.. Electric oven:thermostatically controlled, with interior of non-corroding material, maintain the temperature between 25 C to 110 C +/- 1 C with Air-Circulating fan. Inside Size:1500*1200*900 mm^3
2872. Container: Non Corrodible air tight container: Aluminium Moisture Tins (Diameter: 20,50,75, 80,100mm)
2883. Enamel trays of varying sizes.
289Vacuum Desiccator
290Vacuum Desiccators having clear body (transparent polycarbonate cover and polypropylene base), removable stopcock accepts 1/8 to 1/4 in ID tubing, holds a vacuum of 28 in Hg (711 mm) for 24 hours, TPE caps seal side-arms for non-vacuum use. Maximum clearence above plate should be 195 mm. Suitable desiccating agent for conducting atleast 100 tests must also be provided along it.
291Calcium Carbide Apparatus
292[Ref. Standard IS: 2720 (PART-2)-1973] 1. Metallic Pressure Vessel with clamp for sealing cup and a guage calibrated in percentage water content. 2. 6 Steel balls of about 12.5 mm diameter and 2 steel ball of 25 mm diameter. 3. Absorbent: Calcium Carbide for conducting atleast 100 tests must also be provided along it.
293Specific gravity Equipments
294[Ref. Standard IS:2386 (Part 3)-1963] 1. Pycnometer of 1 litre capacity having a metal conical screw top with a 6 mm diameter hole in its apex. The screw top shall be watertight when it is screwed on the jar. 2. Rubber or fibre washer for inserting in the joint. Consists of a 1 kg Glass Jar with Brass Cone, Locking Ring and Rubber Seal.
295Specific gravity bottle (50 ml) made of borosilicate
296Sieve Analysis Equipments
297[Ref. Standard IS:2386 (Part 1)-1963] 1.IS Sieves (Brass) of High Quality Ranging from 20 micron meter to 80 mm with Pan and Cover: A) Square hole, perforated plate type: 80 mm, 63mm, 50 mm, 40 mm, 31.5 mm, 25 mm, 20 mm, 16 mm, 12.5 mm, 10mm, 6.3 mm and 4.75 mm. B) Fine mesh, wire cloth type: 10 mm,4.75 mm, 2.36 mm, 1.18 mm ,600 micron, 300 micron, 150 micron and 75 micron.pan
2982. Mechanical Shaker Instrument should have a digital timer adjustable from 0-99 minutes. Instrument should produce gyratory motion and tapping motion as well, with a capacity of 7 sieves at a time, with speed control. Suitable for Operation on 220V, Single Phase, 50Hz, AC Supply.
299Flakiness metal gauge
300Elongation Sieve gauge
301Hydrometer
302[Ref. Standard IS: 2720 (PART-4)-1985] 1. Hydrometer: Calibrated at 27°C, range of 0.995 to 1.030 g/cc, graduation lines at interval of 0.0005; in conformity with IS-3104: 1965. The maximum permissible scale error on the hydrometer is plus or minus one scale division. The hydrometer should consist of hydrometer glass jar marked 1000 ml glass cylinder without pour out, which can be used to prepare the soil suspension. The apparatus should be supplied with the rubber bung. Reagents: Hydrogen Peroxide, Sodium hexametaphosphate and Sodium Carbonate for conducting atleast 100 tests must also be provided along it.
303Apparatus for Consistency Limit
304[Ref. Standard IS: 2720 (PART-5), IS:9259, BS 1377] 1. Casgrande apparatus:Casagrande Grooving Tool (Type A of IS: 9259), ASTM Grooving Tool (Type B of IS : 9259) and Gauge Block. Suitable for operation on 220 V, 50 Hz, single phase, AC supply.
3052. Plasticlimit : The plastic limit test is done to determine plastic limit of soil, as per IS : 2720 (Part V) 1985. Plastic limit set comprising of glass plate (10 mm thick and about 45 cm square or larger), Brass Rod (3 mm in diameter and about 10 cm long), Spatula, Moisture Tin & Porcelian Dish ( I2 cm to 15 cm in diameter).
3063. Shrinkage limit:Ref. Standards IS: 2720 (Part6), 10077,ASTM: 0427, BS: 1377,AASHTOT-92 The equipment consist of the followings : • Porcelain Evaporating Dish • Shrinkage Dish • Glass Cup • Perspex Plate, with three Metal Prongs • Perspex Plain Plate • Spatula • Glass Cylinder, graduated, 25 ml x 0.5 ml • Mercury, 750 g • Straight Edge
307Permeability Test Apparatus
308[Ref. Standards IS: 2720 (Part 17)-1986] Laboratory Permeability Apparatus (Falling Head method) For testing soil with coefficient of permeability in the range of 10•3 to 10•1 cm/ sec and maximum particle size of 10 mm. The equipment consist of the following : • Stand with three glass tubesof 6 mm, 10 mm and 20 mm diaapprox. • Metallic Mould 100mmdiax127.3 mm height, 1000 ml volume. • Extension Collar 100 mm dia x 60 mm height. • Drainage Base Plate with a recess for Porous Stone and an Outlet Valve. • Metallic Clamping Ring • Drainage Cap with recess for a Porous Stone and fitted with Inlet Valve and Air Release Valve. • Dummy Plate to serve as False Bottom during compaction. • Porous Stone for Drainage Base Plate. • Porous Stone for Drainage Cap • Rubber Connection Tube 3m long, with Pinch Cock • Overhead Tank required for the constant Head method made of corrosion resistant material, approx. 37 .5 cm dia and 1m high. It is provided with an inlet port at the top, six outlets at the bottom with cocks, air inlet and water filling tube at the top. An arrangement to indicate the water level is also provided. • Rammer 2.6 kg X 310 mm controlled fall.
309Compaction Test Apparatus
3101. Compaction test apparatus for light compaction: Should consists of Compaction mould, complete,with Collar and Base Plate,made of Gunmetal, having 100 mm ID, 127.3 mm height,1,000 ml volume (IS:10074) , 2.6 kg x 310 mm fall, Rammer as per IS 9198
3112. Compaction test apparatus for Heavycompaction: Compaction Mould 152 mm ID,116.4 mm height 2,124 ml volume, 4.54 kg x 457 mm fall,Ref. Standard ASTM D1557for heavy compaction test.
312Universal Automatic compactor
313[Ref. Standards IS: 2720 (Part 7 & 8), BS: 1377-4, ASTM: D698 & D1557 ] It should havea new design motor driven mechanical compactor, useful for soil compaction moulds as per IS, BS &ASTM. Therammer shouldtravels across the mould and the table rotates the mould (Mild steel compaction mould)in equal steps on a stable base.The number of blows per layer can be set at the beginning of the test. Drop -Adjustable as per IS, BS &ASTM Supplied with mild steel mould and extensions for light and heavy compaction both. The equipment is suitable for operation on 220 V, 50 Hz, Single Phase, AC supply. Rammer - Circular faced adjustable weight as per IS, BS &ASTM
314Hydraulic Extruder
315Automatic sample extruder: Should consists of: hydraulic pump, Power pack with quick release couplings,Ejects soil from sampling tubes and moulds upto 60 cm in length and 38 to 150 mm in diameter by a single operation, 60 cm piston stroke, 50kN pushing force, Adapter rings and ejector discs for 38, 50, 75, 100 & 150 mm dia sampling tubes or moulds, included, Sampling tube should beUnrelieved, 38 mm dia x 200 mm long.
316Manually operated sample extruder
317Consolidation Test Apparatus
318[Ref. Standard IS: 2720 (PART-15)-1986] Automatic Consolidation Apparatus, Three Gang with TouchscreenRef. Std. : IS : 2720-15 Technical Specification:Load Capacity : 5 kN Charging and Discharging Rate : C/10 Loading Type : Electromechanical Form Factor : Compact, Table Top,Interface : 7 inch resistive touchscreen with stylus Loading Modes : Manual and Automatic , No. of Steps for Loading : 24 , Data Logging : Square Root and Logarithmic, Displacement resolution : 0.001mm, Displacement Accuracy : Within 1% of working range,Effective Pressure Resolution : 0.01Kg/cm,Data Downloading : Via Pen Drive, Dimensions : 28cm x 34.5cm x 40.8cm without consolidation assembly, Net Weight : 15Kgs (Approx.),Gross Weight : 40Kgs (Approx.) Excluding battery,battery Voltage : 12V, 150Ah (2Nos),Charging and Discharging Rate : C/10, It should comes with Full Touch screen based system.
319Automatic tri-axial Test
320[Ref. Standards IS: 2720 (Part 12)-1981] Automated Triaxial testing apparatus a) Static triaxial cell- 1 no. - Cell shall accommodate specimens with standard diameter 38 mm and 50mm, with length 2 times the diameter of the specimen (l/d ratio 2). - Minimum cell capacity of 2 MPa with transparent acrylic cell wall and should have sufficient valves for hydraulic connections. - Base pedestal and top cap for standard 38 mm and 50 mm and samples shall be supplied. b) Loading frame- 1 no. - The frame should have minimum capacity of 50 kN. - User should be able to set at least a range of speed from 0.0001 to 10 mm/min or above. c) Pressure-volume Controllers- 2 nos. - Computer controlled hydraulic pressure controller: 2 MPa or above with min. resolution of 1 kPa. - Volume change measuring device: at least 200 cm3 with minimum resolution of 0.01 cm3 d) Transducers: - Load cell:10 kN capacity with minimum resolution of 0.0001 kN- 1 no. - LVDT: minimum 25 mm with minimum resolution of 0.001 mm- 1 no. - Pore pressure transducer: at least 2 MPa with minimum resolution of 1 kPa- 1 no. Data logging and software package with following features: - Suitable standard PC with recent configuration - Data acquisition and control software with automated procedure - Triaxial test module should include the following o Unconfined compressive strength test o Unconsolidated undrained test o Consolidated undrained test o Consolidated drained test o Isotropic consolidation, o Anisotropic consolidation, o Stress path test o Option for manual intervention during the automatic testing o Easy instrument and equipment setup and calibration o User defined views / graphs / tables Sample preparation accessories for the supplied standard sizes - Porous disc (Each minimum 20 sets) - Membranes (Each minimum 100 sets) - O Ring (Each minimum 100 sets) - O Ring Tool (Each 4) - Membrane Stretcher (Each 4) - Split Mould 2-part (Each 4) - Filter paper (Grade -1): 60 cm x 60 cm sheets (Pack of 1000)
321Digital large direct shear test apparatus
322Ref. Standards IS:2720 (Part 39, Section 1) IS:11593 Microcontroller based digital direct shear should have: Operation : Motorised Rates of Strain : 72 speeds ranging from 0.0014 to 10.16 mm/min. Specimen Size : 30 x 30 x 15 cm Change gears : 12 ShearLoad capacity : 50 kN 2 Vertical stress : 500 kN/m Suitable for operation on 415V, 50Hz, Three phase, AC Supply. The equipment should consists of the following :Shear Box Assembly ,Plane Gripper Plate ,perforated gripper plate,perforated spacer plate, Base plate , Top loading pad,Shear Box Housing with two Ball Roller Strips,Surcharge Weights 9 Nos, each to give 50 kN/m (0.5 kg/cm ) and 2 Nos, each to give 25 kN/m (0.25 kg/cm) It should comes with Data acquisition system having : - Robust, Stand alone, low power data logger with USB memory stick support - Dual Channel Isolation Technology - Up to 15 Analog (± 50V) sensor inputs -Expandable to 300 analog inputs - 2 Serial ‘Smart Sensor’ ports - SDI-12 (multiple networks) - Programmable Analog Output -Modbus for SCADA connection - Web & FTP client / server - USB memory for easy data and program transfer - Removable Screw Terminals - Inter-Channel isolation up to 100 volts should have analysis and Reporting software Module for Direct Shear Test for single user license
323CBR Test Apparatus
324[Ref. Standards IS: 2720 (Part 12)-1987] Computerized California Bearing Ratio with Data Acquisition System and Software Standards IS:9669, IS:2720 (Part 16) Load Frame, 50 kN (5,000kgf), Capacity, Three Speed 1.5,1.25, 2.5 mm/min Mould - Gun Metal, 150m ID x 175 mm H. Perforated Base Plate - Gun Metal, for Mould. Extension Collar- Gun Metal 150 mm ID x 50 mm high. Penetration Piston 50 mm faces dia. Adjustable Bracket for Penetration Dial Gauge. Circular Metal Spacer Disc, with detachable handle, 148 mm dia. x 47.7 mm high. Annular Metal Weight 2.5 kg, 147 mm dia. with 53 mm dia. central hole. Slotted Metal Weight 2.5 kg, 147 mm dia. with 53 mm dia. slot. Perforated Plate 148 mm dia. with adjustable stem and lock nut. Metal Tripod for Dial Gauge. Cutting Collar Rammer 2.6 kg, 310 mm controlled drop Rammer 4.9 kg, 450 mm controlled drop. Electronic outfit for CBR Test, consists of: Digital Indicator, 1 No. owner: 230 ± 10% mains, 50 Hz, Single Phase, AC supply d) Parameter display: By a selector switch Load Cell, 1 No. Capacity: 50 KN (5000 kgf), Compression Type Maximum overload: 110% of the rated capacity Sensing: Strain Gauges in full bridge configuration Displacement Transducer, 1 No., Range: ±10 mm.
325Relative Density Apparatus
326[Ref. Standards IS: 2720 (Part 12)-1983] Suitable for operation on 220 V, 50 Hz, single phase, AC supply. Ref Standard IS: 2720 (Pt XIV) The equipment consist of the following replaceable parts : • Vibrating Table • Cylindrical Metal Unit Weight Mould, 3000ml capacity • Guide Sleeve with clamp assembly, • Surcharge base plate • Handle • Surcharge Weight Surcharge weight. The total weight together with & is equivalent to 140g/cm2 for the mould being used 1 No. • Cylindrical Metal Unit Weight Mould 15000 ml capacity 1 No. • Guide Sleeve with clamp Assembly • Surcharge base plate • Surcharge weight for AIM 11507. The total weight together&is equivalent to 140g/cm2 for the mould being used 1 No. • Dial Gauge Holder 1 No. • Calibration Bar, 75x300x3 mm 1 No. • Dial Gauge 25 mm travel, 0.01 mm least count, with an extension piece 1 No.
327Wheel barrow
328Constructed in steel with rubber wheels mounted on bearings of varying capacities upto 100kg Tilt angle - 90 degrees
329Measuring cylinders
330a) Material- Plastic Capacity-10ml,20ml,50ml,100ml,200ml,250ml,300ml,500ml,1000ml,2000ml (Set)
331b) Material-Borosillicate Glass Color-Transparent Capacity-10ml,20ml,50ml,100ml,200ml,250ml,300ml,500ml,1000ml,2000ml (Set)
332Measuring Beakers
333Material- Plastic Capacity-10ml,20ml,50ml,100ml,200ml,250ml,300ml,500ml,1000ml,2000ml (Set)
334Weighing Balance
335200 Kg Capacity, Accuracy upto 10 gms
33650 Kg Capacity, Accuracy upto 1 gm
33710 Kg Capacity, Accuracy upto 0.1 gm
338600 gm Capacity, Accuracy upto 0.01 gm (High Precision Lab Scale Digital Analytical Electronic Balance)
339Miscellaneous Equipments
340Trowel of varying sizes
341Shovels of varying sizes
342Metallic Scoops of varying sizes
343Metal Trays of varying sizes
344Palette Knife
345Steel Straight Edge- lightweight, Folding
346Bent Spoon
347Digital Stopwatch
348Plastic Funnel of varying sizes
349Spatula size: 5 " TO 12 "; Material: Stainless Steel
350Flat, hard metal bristle brush
351Wash Bottle
352Glass rod: 15 to 20 cm long and 4 to 5 mm in diameter
353Thermometer
354Digital Thermometer
355Sieve Brushes
356DEPARTMENTAL COMPUTER LAB Bently Academic-Campus Program
357Bently Academic-Campus Program, Bentley Academic campus wide licensing Subscription Programconsisting ofSTAAD pro+STAAD Foundation Advance concrete Desgin+Microstation+Lumen RT + Context capture + Open Roads + water GEMS-2000 pipes +sewer GEMS-2000 Pipes+ Storm CAD Mandatory Features: Minimum 2 weeks training to learn each softwares included in the program (Perpetual License)
358Esri India GIS Academy Program (EIGAP) Basic
359ESRI ArcGIS Advance with following Desktop Extension: -Network Analyst Extension -Spatial Analyst Extension -Geo-statistical Analyst Extension -3D Analyst Extension - Data Interoperability -Maplex -Arc Scan -Data Reviewer -Arc Schematics Extension -Arc Publisher Extension -Subscription Terms: 3 Years -Complementary Esri India User Conference Registration Mandatory Features: Minimum 2 weeks training to learn each softwares included in the program (Perpetual License)
360SAP2000 ULTIMATE V-21
361SAP2000 ULTIMATE V-21 – Educational & Research License developed by Computers and Structures, Inc. Mandatory Features: Minimum 2 weeks training to learn each softwares included in the program (Perpetual License)
362Exelis Envi 5.4 or Latest Version
363Perpetual License for Educational and research purpose Mandatory Features: Minimum 2 weeks training to learn software (Perpetual License)
364ETABS
365Educational & Research License developed by Computers and Structures, Inc. Mandatory Features: Minimum 2 weeks training to learn software (Perpetual License)
366Primavera P6
367Perpetual License for Educational and research purpose Mandatory Features: Minimum 2 weeks training to learn software (Perpetual License)
368Abaqus Unified FEA- Dassault Systems
369Perpetual License for Educational and research purpose Mandatory Features: Minimum 2 weeks training to learn software (Perpetual License)
370MS Project
371Perpetual License for Educational and research purpose Mandatory Features: Minimum 2 weeks training to learn software (Perpetual License)
372Printer cum Scanner
373Print Technology : Laser Paper Size (Original/Image) : A4/A4 Scanning Feature Availability (yes) Duplexing Feature Availability (yes) Wi-Fi Availability(yes) Number of Main Paper Tray 1 or more Each Main Paper Tray Capacity (Number) =150or above Yield of the cartridge/Ink Tank/Ink Pack supplied with Machine as per ISO/IEC: 19752/2004(E) for Black (Number of prints)= 1500 Duty Cycle (No of Prints/month) = 8000 On Site OEM Warranty (Year) =3 years comprehensive warranty for all the parts except toner cartridge. Mandatory Features: 3 Year Waranty Accessories: 2 Cartridges
374Projector
375Hardware Interface: ?VGA, HDMI, USB 2.0 Type A, 802.11 b/g/n Resolution: ?Full HD 1080p Special Features: ?Miracst support to wireslessly cast your screen, Upto 1.07 billion colors reproduced for a rich and wide color space, Game mode available, Manual optical zoom 1.2X for flexible positioning, 1.02 - 1.23 throw ratio for bigger images at shorter throws Display Technology: LCD Image Contrast Ratio: ?16,000 : 1 Aspect Ratio: ?16:9, 4:3, 16:10 Screen Resolution: ?1920 x 1080 Pixels Noise Level: 37 Db Voltage: 240 Volts Wattage: 327 Watts Power Source: ?Corded Electric Refresh Rate: 240 Hz Connector Type: ?VGA, HDMI, Miracast Mounting Type: ?Ceiling Mount & table top Mandatory Features: Remote controlled Foldable Screen
376ENGINEERING GEOLOGY & ROCK MECHANICS LAB Core Drilling Machine (with bits)
377Ref. standard IS: 9179, Heavy duty, pillar type frame, Power capacity 1500W, suitable clamping device for holding the sample, drill travel shall be sufficient to permit continuous runs of 250-300 mm without need of stopping machine, machine should have varying cutting feeds provided with water-fed swivel head which should be connected to suitable water supply, Provision at base for water collection drainage, 5l water tank, 950 rpm/2100 rpm cutting speeds at no load, hose pipe (5 m) with funnel, core drilling bits should be provided of 50 mm, 75 mm and 100 mm dia. Mandatory Features: Bidder shall provide hands-on training for operating the instrument at GHEC Bandla
378Core cutting and Grinding machine
379Ref. standard IS: 9179, feed arrangement for cutting. grinding and polishing rock samples upto 150 mm size, cooling water arrangement. Mandatory Features:Bidder shall provide hands-on training for operating the instrument at GHEC Bandla
380Polishing & Lapping machine
381Ref. standard IS: 9179, 20 cm dia top, adapter to hold polishing cloth or paste, sample Holders to accommodate upto NXsize Cores, Continuous water feed arrangement during operation, ideally suited for the final polishing of mounted rock specimens, motor driven unit with 450/500 rpm, close tolerance of less than or equal to 0.05 mm. Mandatory Features:Bidder shall provide hands-on training for operating the instrument at GHEC Bandla
382Rock Permeability Equipment
383Moulds of 50mm diameter and 100mm height with collar, Top Plate, Base Plate with access for Porous Stone, Air compressor capacity: 7kg/cm2, Reservoir Tank with gauge valves, Flow Control Regulator, Foot pump, Porous Stone to fit into base plate, Connecting Hose, High Viscosity Oil (5L can). Mandatory Features:Bidder shall provide hands-on training for operating the instrument at GHEC Bandla
384Uniaxial compression strength test equipment for rocks
385Ref. Standard : ASTM 2938, capacity: 200 kN, steel discs at specimen ends must be of hardness greater than 30 HRC, Axial load is continuously increased on the specimen until peak load and failure are obtained, Proving Ring, 100 kN, Dial Gauge 25mm travel, 0.01mm least count, Platen Set as per ASTM 2938 requirements. Mandatory Features:Bidder shall provide hands-on training for operating the instrument at GHEC Bandla
386Digital Point Load Index Tester
387Ref. Standard IS:8764, ability to test wide range of core sizes, Capacity: 100 kN with least count 0.01 kN, Digital Indicator with sensor. Mandatory Features:Bidder shall provide hands-on training for operating the instrument at GHEC Bandla
388Digital Brazilian Test Apparatus
389Ref. standard IS: 10082, Capacity : 500 KN , electrically operated, To test specimens from 50 mm dia to100 mm dia, A pair of loading jaws, designed so as to contact a disc shaped sample at diametrically opposed surfaces over an arc of contact of about 10 degrees at failure, The set of jaws supplied with the equipment designed for 50 mm dia specimen and therefore it is essential to order jaws for required sizes, if the samples of other diameters are to be tested, A set of plain platens with the jack to enable testing of cube and circular specimens upto 50 mm size for compressive strength. Mandatory Features:Bidder shall provide hands-on training for operating the instrument at GHEC Bandla
390Rock shear strength testing machine
391Ref. Standard : ASTM D-5607-95, IS 12634,The equipment must be used for Direct Shear Laboratory Test in Rock Samples. The test measures peak & residual Direct Shear Strength as a function of stress normal to the sheared plane. The equipment can be used for testing Core, Lump specimens,shear Box (300mm x 300mm x 100mm), Jack Capacity 100kN, a) One jack for normal Load b) One jack for Shear Load c) One jack to return the sample to original position, Dial Gauges, 25mm x 0.01mm, a) 2 Nos for measurement of Shear Displacement b) 4 Nos for normal displacement & consolidation of sample, Hydraulic Pump, Load Gauge 0-100kN x 0.5kN , Flexible hose pipe 2 meters, Moulds for Casing the samples (Wooden), Magnetic Stand, equipment must have NABL certification. Mandatory Features:Bidder shall provide hands-on training for operating the instrument at GHEC Bandla
392Slake durability test Apparatus
393Ref. Standard: IS : 10050, Facility to test upto four sets of samples, Quick couplings for assembly and removal of drums, determination of resistance offered by rock to weathering and disintegration when subjected to immersion in water, motor on base board capable of driving two or more drums at a speed of 20 rpm, A suitable number of plastic water troughs, each designed to contain a test drum with quick release drive assemblies, permit 1 to 4 drums to be driven at one time. The test drums are supported on water lubricated bearings allowing 40 mm unobstructed clearance below the drum and a trough water level 20 mm below the axis of the drum. Drums made of brass and comprising 2 mm wire mesh cylinders of 140 mm dia and 100mm length. Mandatory Features:Bidder shall provide hands-on training for operating the instrument at GHEC Bandla
394Rock Bolt Pull out Test Apparatus
395Ref. Standard: IS : 11309, 500kN with Double Acting Jack with Standard couplers and should consists of : centre hole hydraulic jack, dial gauge (0.01x25mm), hands operated two stage pump, reaction frame, load gauge and pressure hoses. It should comes with Calibration Certificate. Mandatory Features:Bidder shall provide hands-on training for operating the instrument at GHEC Bandla.
396ELECTRICAL MACHINE LAB Universal AC Machines Trainer
397Mains Supply : 415VAC ± 10%, 50Hz with VSS to monitor voltage Single Phase transformer Primary Voltage : 0-125V, 0-125V ± 10%, 50Hz Secondary Voltage: 0-125V, 0-125V ± 10%, 50Hz Current Capacity : 4A Winding : Copper Three Phase transformer Primary Voltage : 440V ± 10%, 50Hz Secondary Voltage : 240V ± 10%, 50Hz Current Capacity : 4A Winding : Copper DC Excitation UnitOutput Voltage : 0 to 300VDC ± 10% Current Capacity : 2A DC Power Supply (With overload protection) must be separate unit for both the caseMains Supply : 220VAC ± 10%, 50Hz Output Variable voltage: 0 - 240VDC ± 10%Current Rating : 15AAC Ammeter, 72 X 72mm(2Nos.) Range : 10A Topology : Controller BasedAC Voltmeter, 72 X 72mm(2Nos.) Range : 500V Topology: Controller BasedDC Ammeter, 72 X 72mm(2Nos.) Range : 20A Topology : Controller BasedDC Voltmeter, 72 X 72mm(2Nos.) Range : 300V Topology: Controller BasedSingle Phase Wattmeter, 96 X 96mm(2Nos.) Range : 4.5kWTopology x: Controller BasedDigital Handheld Tachometer (lutron) Range: 19,999 rpmType :Contact / Non-contact Protective Devices Three Phase MCB (TPN) : 1 No. (Havells/ Siemens /anchor) Single Phase MCB (DP) : 1 No. (Havells/ Siemens /anchor) Glass Fuses : 6 Nos. Grounding Nut: Available at the rear side of the panel Interconnections : 4mm BS-10 Safety TerminalsTechnical Specification of Machines Type : 1-Ø Capacitor Start Induction Motor Make : Havells /Siemens /CG Power Rating : 1HP Voltage Rating : 220V AC ± 5%, 50Hz Rated Speed : 1440RPM ± 7.5% Insulation : Class "B" Loading arrangement : Mechanical Spring Balance : 2 Nos. (Tubular Type) Brake Drum/Pulley : Aluminum Casted with heat suppression facility Machine Base : “C” Channel Protection : Fuses (mounted at the terminal box of the Machines) Type : 3-Ø Squirrel Cage Induction MotorPower Rating : 1HP Make : Havells /Siemens /CG Voltage Rating : 415V AC ± 5%, 50Hz Rated Speed : 1440RPM ± 7.5% Insulation : Class "B" Loading arrangement : Mechanical Spring Balance : 2 Nos. (Tubular Type) Brake Drum/Pulley : Aluminum Casted with heat suppression Facility Machine Base : “C” Channel Protection : Fuses (mounted at the terminal box of the Machines) Type : 3-Ø Slip Ring Induction MotorPower Rating: 3HP Make : Alfa / Elmo Voltage Rating : 415V AC ± 5%, 50Hz Rated Speed : 1440RPM ± 7.5% Insulation : Class "B" Loadingarrangement : Mechanical Spring Balance : 2 Nos. (Tubular Type) Brake Drum/Pulley : Aluminum Casted with heat suppression Facility Machine Base : “C” Channel Protection: Fuses (mounted at the terminal box of the Machines) Type : 3-Ø AC Three Phase Synchronous Motor Both the Machines are flexibly coupled and Mounted on a Single "C" Channel Base Three Phase Synchronous Machine (act as Motor) Type : Salient Type Make : Alfa / Elmo Power Rating : 3 HP Excitation Voltage : 180Vdc ± 10% DC Machine (act as Motor) Type : Shunt Make : Alfa / Elmo Pow r Rating : 2 HP Rated Speed : 1500RPM ± 7.5% Insulation : Class "B’ Loading Arrangement : Electrical Type of Coupling : Flexible “Lovejoy” Coupling Machine Base : “C” Channel Protection : Fuses (mounted at the terminal box of the Machines) Type : 3-Ø Induction Motor coupled with DC Shunt Generator (Ward Leonard Method) Both the machines are flexibly coupled and mounted on a “C” Channel base AC Machine (Act as prime mover) Type: Three Phase squirrel cage induction motor Make : Havells /Siemens /CG Voltage Rating: 415VAC ± 10%, 50Hz Speed: 1440 rpm ± 10% Operating Supply: 230VAC • Classroom/ laboratory Teaching, Learning and Simulation Content: Should have easy explanation of various complex topics with animation and simulation for ease of student learning.The Content should also support learning through videos, graphs, charts, along with mandatory rich content and theory to understand fundamental concepts, interactive learning objects, FAQ, MCQ etc. The content should supply either the digital online access or license protection should be supported through USB hardware dongle.
398Universal DC Machines Trainer
399± 10%, 50Hz DC Power Supply (with field failure, overload protection, must be operated at pmdc and shunt mode) Mains Supply: 220VAC ± 10%, 50Hz Output Variable voltage: 0 - 240VDC ± 10% Current Rating: 15A Single Phase Auto-Transformer Type : Close Type Operating Rating: 230V AC ±10%, 50Hz Output Voltage : 0 - 270V AC ±10%, 50Hz Current: 6A DC Digital Ammeter (3Nos.) Range: 20A Topology: Controller Based DC Digital Voltmeter (3Nos.) Range: 300V Topology: Controller Based AC Digital Ammeter Range: 10A Topology: Controller Based AC Digital Voltmeter Range: 500V Topology: Controller Based DC Excitation Unit Voltage rating: 350VDC± 10% Current rating: 2A Topology: Autotransformer based Digital Handheld Tachometer Range: 19,999 rpm Type:Contact / Non-contact Interconnections: 4mm BS-10 Safety Terminals Technical Specification of Machines compatible with above workbench (Optional) Type: Universal Motor Make: Alfa / Elmo Power Rating: 1HP Voltage Rating: 220V AC & DC ± 5% Rated Speed: 1500RPM ± 7.5% Insulation: Class "B" Loading arrangement: Mechanical Spring Balance: 2Nos.(Tubular Type) Brake Drum/Pulley: Aluminum Casted with heat suppression facility Machine Base: “C” Channel Protection: Fuses (mounted at the terminal box of the Machines) Type: PMDC Motor Make: Alfa / Elmo or equivalent Power Rating: 1HP Voltage Rating: 220V DC ± 5% Rated Speed: 1500RPM ± 7.5% Insulation: Class "B" Loading arrangement: Mechanical Spring Balance: 2Nos. (Tubular Type) Brake Drum/Pulley: Aluminum Casted with heat suppression facility Machine Base: “C” Channel Protection: Fuses (mounted at the terminal box of the Machines) Type: Shunt Motor Make: Alfa / Elmo Power Rating: 1HP Voltage Rating: 220V DC ± 5% Rated Speed: 1500RPM ± 7.5% Insulation: Class "B"Loading arrangement: Mechanical Spring Balance: 2Nos.(Tubular Type) Brake Drum/Pulley: Aluminum Casted with heat suppression facility Machine Base : “C” Channel Protection: Fuses (mounted at the terminal box of the Machines) Type: Series Motor Make: Alfa / Elmo Power Rating: 1HP Voltage Rating: 220V DC ± 5% Rated Speed: 1500RPM ± 7.5% Insulation: Class "B" Loading arrangement: Mechanical Spring Balance: 2Nos.(Tubular Type) Brake Drum/Pulley: Aluminum Casted with heat suppression facility Machine Base: “C” Channel Protection: Fuses (mounted at the terminal box of the Machines) Type: Compound Motor Make: Alfa / Elmo Power Rating: 1HP Voltage Rating: 220V DC ± 5% Rated Speed: 1500RPM ± 7.5% Insulation: Class "B" Loading arrangement: Mechanical Spring Balance: 2Nos.(Tubular Type) Brake Drum/Pulley: Aluminum Casted with heat suppression facility Machine Base: “C” Channel Protection: Fuses (mounted at the terminal box of the Machines) Type: DC Shunt Motor DC Shunt GeneratorBoth the Machines are flexibly coupled and Mounted on a Single "C" Channel Base DC Machine (acts as prime mover) Type: Shunt Make: Alfa / Elmo Voltage Rating: 220V DC ± 5% Rated Speed: 1500RPM ± 7.5% Insulation: Class "B" DC Machine (acts as generator) Type: Shunt Make: Alfa / Elmo Power Rating: 1HP Rated Speed: 1500RPM ± 7.5% Insulation: Class "B" Shaft extension: Single Sided Loading Arrangement: Electrical Type of Coupling: Flexible “Lovejoy” Coupling Machine Base: “C” Channel Protection: Fuses (mounted at the terminal box of the Machines Type: DC Shunt Motor DC Series Generator Both the Machines are flexibly coupled and Mounted on a Single "C" Channel Base DC Machine (acts as prime mover) Type: Shunt Make: Alfa / Elmo Voltage Rating: 220V DC ± 5% Rated Speed: 1500RPM ± 7.5% Insulation: Class "B" DC Machine (acts as generator) Type: Series Make: Alfa / Elmo Power Rating: 1HP Rated Speed: 1500RPM ± 7.5% Insulation: Class "B" Shaft extension : Single Sided Loading Arrangement : Electrical Type of Coupling: Flexible “Lovejoy” Coupling Machine Base: “C” Channel Protection: Fuses (mounted at the terminal box of the Machines Type: DC Shunt Motor DC Compound Generator Both the Machines are flexibly coupled and Mounted on a Single "C" Channel Base DC Machine (acts as prime mover) Type: Shunt Make: Alfa / Elmo Voltage Rating: 220V DC ± 5% Rated Speed: 1500RPM ± 7.5% Insulation: Class "B"DC Machine (acts as generator) Type: Compound Make: Alfa / Elmo Power Rating: 1HP Rated Speed: 1500RPM ± 7.5% Insulation : Class "B" Shaft extension: Single Sided Loading Arrangement: Electrical Type of Coupling: Flexible “Lovejoy” Coupling Machine Base: “C” Channel Protection: Fuses (mounted at the terminal boxof the Machines For FieldTest of DC Series Machine Type: DC Series Motor DC Series Generator Both the Machines are flexibly coupled and Mounted on a Single "C" Channel Base DC Machine (acts as prime mover)Type: Series Make : Alfa / Elmo Voltage Rating: 220V DC ± 5% Rated Speed: 1500RPM ± 7.5% Insulation: Class "B" DC Machine (acts as generator) Type: Series Make: Alfa / Elmo Power Rating: 1HP Rated Speed: 1500RPM ± 7.5% Insulation: Class "B" Shaft extension: Single Sided Loading Arrangement: Electrical Type of Coupling: Flexible “Lovejoy” Coupling Machine Base: “C” Channel Protection: Fuses (mounted at the terminal box of the Machines For Hopkinson Test of DC Shunt Machine Type: Two identical DC Shunt Motor coupledBoth the Machines are Identical and flexibly coupled to Mounted on a Single "C" Channel Base DC MachineType: Shunt (2Nos.) Make: Alfa / Elmo Power Rating: 1HP Rated Speed: 1500RPM ± 7.5% Insulation: Class "B" Shaft extension: Single Sided Loading Arrangement: Electrical Type of Coupling: Flexible “Lovejoy” Coupling Machine Base: “C” Channel Protection: Fuses (mounted at the terminal box of the Machines Type: 3-Ø Induction Motor coupled with DC Shunt GeneratorBoth the machines are flexibly coupl ed and mounted on a “C” Channel base AC Machine (Act as prime mover) Type: Three Phase squirrel cage induction motor Make: Havells / Siemens / L&T Voltage Rating: 415VAC ± 10%, 50Hz Speed: 1440 rpm ± 10% Insulation: Class ‘F’ Winding: Copper Loading arrangement : Electrical DC Machine (Act as generator) Type: Shunt Make: Alfa / Elmo Power Rating: 1 HPGenerated Voltage Rating: 220VDC ± 10% at load Speed: 1500 rpm ± 10% Insulation: Class ‘F’ Winding: Copper Type of Coupling: Flexible “Lovejoy” Coupling Machine Base: “C” Channel Type: 3-Ø Induction Motor coupled with DC Series Generator Both the machines are flexibly coupled and mounted on a “C” Channel base AC Machine (Act as prime mover) Type: Three Phase squirrel cage induction motor Make: Havells / Siemens / L&T Voltage Rating: 415VAC ± 10%, 50Hz Speed: 1440 rpm ± 10% Insulation: Class ‘F’ Winding: Copper Loading arrangement: Electrical DC Machine (Act as generator) Type: Series Make: Alfa / Elmo Power Rating: 1 HPGenerated Voltage Rating: 220VDC ± 10% at load Speed: 1500 rpm ± 10% Insulation: Class ‘F’ Winding: Copper Type of Coupling: Flexible “Lovejoy” Coupling Machine Base: “C” Channel Type: 3-Ø Induction Motor coupled with DC compound GeneratorBoth the machines are flexibly coupled and mounted on a “C” Channel base AC Machine (Act as prime mover) Type: Three Phase squirrel cage induction motor Make: Havells / Siemens / L&T Voltage Rating: 415VAC ± 10%, 50Hz Speed: 1440 rpm ± 10% Insulation: Class ‘F’ Winding: Copper Loading arrangement: Electrical DC Machine (Act as generator) Type: Compound Make: Alfa / Elmo Power Rating: 1 HPGenerated Voltage Rating: 220VDC ± 10% at load Speed: 1500 rpm ± 10% Insulation: Class ‘F’ Winding: CopperType of Coupling: Flexible “Lovejoy” Coupling Machine Base: “C” Channel SupportingAccessories supplied with Workbench •Patch Cords of different color scheme of appropriate value •Single Phase Mains Cord •Digital Tachometer •Extra Glass Fuses •Learning Material Manual•Resistive LoadNature of Load: Resistive Loading Topology: Through toggle switches/MCB’s Type of Load: Discrete Single Phase Operation Voltage: 240V AC/DC ± 10%, 50Hz Current: 12ALoading steps: 12 in step of 1A Three Phase Star OperationVoltage: 415V AC ± 10%, 50Hz Current: 4A (each phase) Loading steps: 4 per phase in step of 1A Three Phase Delta OperationVoltage: 415V AC ± 10%, 50Hz Current: 12A (each line) Loading steps: 4 per phase in step of 2.5A (Approx.) Star/Delta Switch: 415V, 25A Mains MCB:32A (TPN) (Havells/ Siemens /anchor) Mains Indicators:3Nos (for each phase) •Sliding Rheostat • Classroom/ laboratory Teaching, Learning and Simulation Content: Should have easy explanation of various complex topics with animation and simulation for ease of student learning.The Content should also support learning through videos, graphs, charts, along with mandatory rich content and theory to understand fundamental concepts, interactive learning objects, FAQ, MCQ etc. The content should supply either the digital online access or license protection should be supported through USB hardware dongle.
400Cut Section
401Cut Section of DC Shunt Motor (in running mode) Rating:1HP Voltage Rating:220VDC± 10% Speed:1500 RPM± 7.5% Insulation:Class ‘B/F’ Winding:Copper Direction:Clock & anticlockwise Shaft: Single Extension Enclosure: SPDP Cut Section of DC Series Motor (in running mode) Rating:1HP Voltage Rating:220VDC± 10% Speed:1500 RPM± 7.5% Insulation:Class ‘B/F’ Winding:Copper Direction:Clock & anticlockwise Shaft: Single Extension Enclosure: SPDP Cut Section of DC Compound Motor (in running mode) Rating:1HP Voltage Rating:220VDC ± 10% Speed:1500 RPM± 7.5% Insulation:Class ‘B’ Winding:Copper Direction:Clock & anticlockwise Shaft: Single Extension Enclosure: SPDP Cut Section of Single phase Capacitor Start Motor (in running mode) Rating:1HP Voltage Rating:220VAC± 10% Speed:1440 RPM± 7.5% Insulation:Class ‘B’ Winding:Copper Direction:Clock & anticlockwise Shaft : Single Extension Enclosure: TEFC Cut Section of Three phase squirrel cage Motor (in running mode) Rating:1HP Voltage Rating:415VAC± 10% Speed:1440 RPM± 7.5% Insulation:Class ‘B’ Winding:Copper Direction:Clock & anticlockwise Shaft: Single Extension Enclosure: TEFC Cut Section of Three phase slip ring Motor (in running mode) Rating:3HP Voltage Rating:415VAC ± 10% Speed:1440 RPM± 7.5% Insulation:Class ‘B’ Winding:Copper Direction:Clock & anticlockwise Shaft: Single Extension Enclosure: SPDP Cut Section of Three phase synchronous Motor (in running mode) Rating:3HP Voltage Rating:415VAC ± 10% Excitation Voltage:110VDC ± 10% Speed:1500 RPM± 7.5% Insulation:Class ‘B’ Winding:Copper Direction:Clock & anticlockwise Shaft: Single Extension Enclosure: SPDP Scope of Learning •Identification of different part of Machines •Understanding the functional structure of Machine • Classroom/ laboratory Teaching, Learning and Simulation Content: Should have easy explanation of various complex topics with animation and simulation for ease of student learning.The Content should also support learning through videos, graphs, charts, along with mandatory rich content and theory to understand fundamental concepts, interactive learning objects, FAQ, MCQ etc. The content should supply either the digital online access or license protection should be supported through USB hardware dongle.
402Single Phase Capacitor Start Induction Motor Training System
403Digital microcontroller based measuring devices with high accuracy and resolution, Control panel not less than 680 x 320 x 480mm, Built-in Single phase autotransformer, Control board Consist of MS Material with power coating / Epoxy paint to avoid any rust, Screen printed symbols, circuit diagrams, graphics or photos wherever requires., Designed using standard BS-10 terminal and patch cords for electrical safety, Machine windingconsist of copper for long term service, Machine with Class “F” Insulation, Machine with standard mechanical loading structure , Machine with standard tabular spring balance with zero adjustment facility, 1.5 mm x 3mm Heavy Duty Base/Channel with facility to concrete, Brake-Drum/Pulley with heat suppression facility inside it, Provided with non contact Digital speed measuring equipment,Equipped with supply indicator lamp, Earthing screw provided at the back side of the control board,Product supplied with protection fuses, colored patch cords, single phase cords, learning manual having theory operating procedure with connecting diagram, FAQ, Glossary, etc Technical Specifications: Mains Supply : 220VAC ±10%, 50Hz, Single Phase Induction Motor, Type: Capacitor Start Induction Run, Make: HAVELLS / CG / SIEMENS, Rating : 1HP, Voltage Rating: 220VAC ±10%, 50Hz, Current Rating: As per standard,Speed: 1440 RPM ±10%, Insulation : Class ‘F’, Duty: Continuous, Enclosure: TEFC, Mounting: Horizontal Foot Mounted, Shaft Extension: Single Sided, Loading arrangement: Mechanical, Brake Drum/Pulley: MS/Aluminum Casted with heat suppression facility inside it,Spring Balance: 2Nos. (Salter make), Loading Nut & Bolts: Brass material, Terminals box: Epoxy paint with terminals and fuses brought out at the top, Machine Base:MS “C” Channel with suitable interconnection, Digital meter (72x72mm)s used: AC Wattmeter: 1 No., AC Voltmeter: 1 No., AC Ammeter: 1 No., Single Phase Variac, Primary Voltage: 220VAC ±10%, 50Hz, Secondary Voltage : 0-220VAC ±10%, 50Hz, Current Rating: 10A, Digital Tachometer: Range: 19,999 rpm, Type:Contact / Non-contact, Protection Devices MCB (DP): 1No (Havells/ Siemens /anchor), Glass Fuse : 1No, Grounding Nut : Available at the rear side of the panel, Scope of Learning: Study about single phase capacitor start capacitor run motor with following topics., Understanding fundamentals and operational working principles, Running and reversing phenomenon, Performance at no-load test and correspondingly calculate equivalent parameters and power factor, Performance at block-rotor test and correspondingly calculate equivalent parameters and power factor, Performance at load condition (load test) and correspondingly plot a graph between measured electrical parameters such as, current, voltage, torque (by calculation), speed, etc., Supporting Accessories supplied with Product, Patch Cords of different color scheme, Single Phase Mains Cord, Extra Glass Fuses, Digital Tachometer, Learning Material Manual
404Three Phase Squirrel Cage Induction Motor Training System
405Features: Digital microcontroller based measuring devices with high accuracy and resolution, Control panel not less than 680 x 320 x 480mm, Control board Consist of MS Material with power coating / Epoxy paint to avoid any rust, Screen printed symbols, circuit diagrams, graphics or photos wherever requires., Control board having door at the rear side for protection purpose., Designed using standard BS-10 terminal and patch cords for electrical safety, Machine windingconsist of copper for long term service, Machine with Class “F” Insulation, Machine with standard mechanical loading structure, Machine with standard tabular spring balance with zero adjustment facility, 1.5 mm x 3mm Heavy Duty Base/Channel with facility to concrete machine , Brake-Drum/Pulley with heat suppression facility inside it, Provided with non contact Digital speed measuring equipment, Equipped with supply indicator lamps, Earthing screw provided at the back side of the control board, Product supplied with protection fuses, colored patch cords, single phase\ three phase cords, learning manual having theory operating procedure with connecting diagram, FAQ, Glossary, etc Technical Specifications: Mains Supply: 415VAC ±10%, 50Hz, Three Phase Induction Motor: Type: Squirrel Cage, Make : HAVELLS / CG / SIEMENS, Rating: 1HP, Voltage Rating : 415V ±10%, 50Hz, Current Rating : As per standard, Speed: 1440 RPM ±10%, Insulation: Class ‘F’, Duty: Continuous, Enclosure : TEFC, Mounting : Horizontal Foot Mounted, Shaft Extension : Single Sided, Loading arrangement : Mechanical , Brake Drum/Pulley: MS/Aluminum Casted with heat suppression facility inside it, Spring Balance : 2Nos. (Salter make), Loading Nut & Bolts : Brass material, Terminals box: Epoxy paint with terminals and fuses brought out at the top, Machine Base:MS “C” Channel with suitable interconnection, Digital meters (72x72mm) used: AC Wattmeter: 2 Nos., AC Voltmeter: 1 No., AC Ammeter: 1 No., Digital Tachometer:Range : 19,999 rpm , Type:Contact / Non-contact, Protection Devices: MCB (TPN): 1No (Havells/ Siemens /anchor), Glass Fuse : 1No, Grounding Nut: Available at the rear side of the panel, Scope of Learning Study about three phase squirrel cage induction motor with following topics., Understanding fundamentals and operational working principles, Running and reversing phenomenon, Slip test measurement,Performance at no-load test and correspondingly calculate equivalent parameters and power factor, Performance at block-rotor test and correspondingly calculate equivalent parameters and power factor, Performance at load condition, Supporting Accessories supplied with product: Patch Cords of different color scheme, Single Phase and Three Phase Mains Cord, Extra Glass Fuses, Digital Tachometer, Learning Material Manual, 6A, Three Phase Closed Type Autotransformer
406Three Phase Slip Ring Induction Motor Training System
407Features: Digital microcontroller based measuring devices with high accuracy and resolution, Control panel not less than 680 x 320 x 480mm, Control board Consist of MS Material with power coating / Epoxy paint to avoid any rust, Screen printed symbols, circuit diagrams, graphics or photos wherever requires., Designed using standard BS-10 terminal and patch cords for electrical safety, Machine windingconsist of copper or high grade material for long term service, Machine with Class “F” Insulation, Machine with standard mechanical loading structure, Machine with standard tabular spring balance with zero adjustment facility, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts, Brake-Drum/Pulley with heat suppression facility inside it, Separate auxiliary supply will be required to actuate digital measuring devices, Provided with non contact Digital speed measuring equipment, Equipped with supply indicator lamps, Earthing screw provided at the back side of the control board, Product supplied with protection fuses, colored patch cords, single phase\ three phase cords, learning manual having theory operating procedure with connecting diagram, FAQ, Glossary, etc Technical Specifications: Mains Supply: 415VAC ±10%, 50Hz, Three Phase Induction Motor: Type: Slip Ring, Make : Alfa / Elmo, Rating: 3HP, Voltage Rating : 415VAC ±10%, 50Hz, Current Rating : As per standard, Speed: 1440 RPM ±10%, Insulation : Class ‘F’, Duty : Continuous, Enclosure : TEFC, Mounting : Horizontal Foot Mounted, Shaft Extension: Single Sided, Loading arrangement : Mechanical , Brake Drum/Pulley: MS/Aluminum Casted with heat suppression facility inside it, Spring Balance : 2Nos. (Salter make), Loading Nut & Bolts : Brass material, Terminals box : Epoxy paint with terminals and fuses brought out at the top, Machine Base :MS “C” Channel with suitable interconnection, Digital meters (72x72mm) used, AC Wattmeter: 2 Nos., AC Voltmeter : 1 No., AC Ammeter : 1 No., Digital Tachometer: Range: 19,999 rpm, Type:Contact / Non-contact, Protection Devices: MCB (TPN): 1No (Havells/ Siemens /anchor), Glass Fuse : 1No, Grounding Nut : Available at the rear side of the panel, Scope of Learning: Study about three phase slip ring induction motor with following topics., Understanding fundamentals and operational working principles, Running and reversing phenomenon, Slip test measurement, Performance at no-load test and correspondingly calculate equivalent parameters and power factor, Performance at block-rotor test and correspondingly calculate equivalent parameters and power factor, Performance at load condition, Supporting Accessories supplied with product, Patch Cords of different color scheme, Single & Three Phase Mains Cord, Extra Glass Fuses, Digital Tachometer, Learning Material Manual, 8A, Three Phase Closed Type Autotransformer, Rotor Resistance Starter
408Three Phase Synchronous Motor Training System
409Features: Digital microcontroller based measuring devices with high accuracy and resolution, Built-in DC Excitation for three phase synchronous generator, Control panel not less than 680 x 320 x 480mm, Consist of MS Material with power coating to avoid any rust, Screen printed symbols, circuit diagrams, graphics or photos wherever requires, Designed using standard BS-10 terminal and patch cords for electrical safety, Machine windingconsist of copper for long term service, Machine with Class “F” Insulation, Machine with standard electrical loading arrangement, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts, Separate auxiliary supply will be required to actuate digital measuring devices, Provided with contact Type Digital speed measuring equipment, Equipped with supply indicator lamps, Earthing screw provided at the back side of the control board, Product supplied with protection fuses, colored patch cords, single phase\ three phase cords, learning manual having theory operating procedure with connecting diagram, FAQ,etc, Technical Specifications: Machines mounted on a “C” Channel base with suitable interconnection, Three Phase Auto-Synchronous AC Machine (act as Motor), Type : Salient type with damper winding, Make : Alfa / Elmo, Rating : 3HP, Voltage Rating : 415VAC ± 10%, 50Hz, Rated Current: As per standard, DC Excitation Voltage : 110VDC ± 10%,DC Excitation Current: 2A (approx.), Speed : 1500 rpm ± 1%, Insulation: Class ‘F’, Enclosure : SPDP, Duty: Continuous, Mounting : Horizontal Foot Mounted, Shaft Extension : Single Sided, Loading arrangement : Electrical , Terminals box : Powder Coating with terminals and fuses brought out at the top, Machine Base: MS “C” Channel with suitable interconnection, DC Machine (act as generator), Type: Shunt, Make: Alfa / Elmo, Power Rating: 2HP, Voltage Rating : 220VDC ± 10% , Speed : 1500 rpm ± 10%, Insulation: Class ‘F’, Enclosure : SPDP, Duty : Continuous, Mounting : Horizontal Foot Mounted, Shaft Extension:Single Sided, Digital meter (72x72mm)s used, Voltmeter: 2 No, Ammeter: 2 No, Wattmeter: 2 Nos., DC Excitation Unit, Voltage rating : 300VDC± 10%, Current rating: 2A, Topology : Autotransformer based, Digital Tachometer, Range : 19,999 rpm , Type:Contact / Non-contact, Protection Devices, DOL Starter: 1No(Havells/ Siemens /anchor), Glass Fuse : 3Nos (Havells/ Siemens /anchor), Grounding Nut: Available at the rear side of the panel Scope of Learning, To study the operational working ofThree Phase Synchronous Motor, To study the V curve of Three Phase Synchronous Motor at different loading condition, To study the Inverse V curve of the Three Phase Synchronous Motor at different loading condition, Supporting Accessories supplied with Product,Patch Cords of different color scheme, Single Phase/Three Phase Mains Cord , Digital Tachometer, Extra Glass Fuses, Learning Material Manual, Resistive Load, Nature of Load: Resistive Loading Topology : Through toggle switches/MCB’s, Type of Load : Discrete, Single Phase Operation: Voltage : 240V AC/DC ± 10%, 50Hz, Current: 12A , Loading steps : 12 in step of 1A,Three Phase Star Operation :Voltage : 415V AC ± 10%, 50Hz, Current : 4A (each phase), Loading steps : 4 per phase in step of 1A, Three Phase Delta Operation : Voltage : 415V AC ± 10%, 50Hz, Current : 12A (each line), Loading steps : 4 per phase in step of 2.5A (Approx.), Star/Delta Switch: 415V, 25A, Mains MCB :32A (TPN), Mains Indicators:3Nos (for each phase)
410Voltage Regulation of Three Phase Synchronous Generator using EMF Method
411Features: Machine with standard electrical loading arrangement, Machine winding consist of copper for long term service, Control panel not less than 680 x 320 x 480mm, Machine Conforms to all leading industrial standards with Class “F” Insulation, 2mm x 4mm Heavy Duty Base/Channel with facility to concrete machine, Standard Lovejoy coupler is used to couple machines, Provided with non contact Digital speed measuring equipment, Digital microcontroller based measuring devices with high accuracy and resolution, Built-in DC Regulated Power Supply,Inbuilt DC Excitation Unit for field winding of three phase synchronous generator, Front board consist of MS Material with power coating / Epoxy paint to avoid any rust, Specially designed BS10 Terminals and patch cords for electrical safety, Three Phase Supply indication lamps, Earthing screw provided at the back side of the control set-up, Screen Printed diagrammatic representation for the ease of connections., Product should be provided with protection fuses, colored patch cords, single phase cords, learning manual having theory operating procedure with connecting diagram, FAQ, Glossary, etc, Technical Specifications: Both the machines are flexibly coupled and mounted on a “C” Channel base with suitable interconnection, DC Machine (act as prime mover), Type: Shunt, Make: Alfa / Elmo, Power Rating: 2HP, Voltage Rating : 220VDC ± 10% , Speed : 1500 rpm ± 10%, Insulation : Class ‘F’, Enclosure: SPDP, Duty: Continuous, Mounting: Horizontal Foot Mounted, Shaft Extension: Single Sided, Loading arrangement : Electrical, Terminals box : Epoxy paint with terminals and fuses brought out at the top, Machine Base :MS “C” Channel with suitable interconnection, Three Phase Auto-Synchronous AC Machine (Act as generator): Type : Salient type with damper winding, Make: Alfa / Elmo, Power Rating: 3HP, Voltage Rating: 415VAC ± 10%, 50Hz, Configuration : Delta Connected, Rated Current : As per standard, DC Excitation Voltage : 110VDC± 10%, DC Excitation Current: 2A, Speed : 1500 rpm ± 1%, Insulation: Class ‘B/F’, Enclosure : SPDP, DC Excitation Unit, Voltage rating: 350VDC± 10%, Current rating: 2A, Topology : Autotransformer based, DC Power Supply (With overload protection), Mains Supply : 220VAC ± 10%, 50Hz, Output Variable voltage: 0 - 240VDC ± 10% , Current Rating: 15A, Digital meter (72x72mm)s used, AC Voltmeter: 1 No, AC Ammeter: 1 No , DC Voltmeter: 1 No, DC Ammeter: 2 Nos , Digital Tachometer: Range : 19,999 rpm , Type:Contact / Non-contact, Protection Devices, MCB (DP): 1No (Havells/ Siemens /anchor), Glass Fuse : 3Nos, Grounding Nut : Available at the rear side of the panel, Scope of Learning: To study open circuit characteristic(OCC) of three phase synchronous generator, To study short circuit characteristic (SCC) of three phase synchronous generator, To study short circuit ratio (SCR) of three phase synchronous generator, To study voltage regulation of three phase synchronous generator using EMF method, Supporting Accessories supplied with product, Patch Cords of different color scheme, Single Phase Mains Cord, Digital Tachometer, Extra Glass Fuses, Learning Material Manual
412Voltage Regulation of Three Phase Synchronous Generator by Direct Loading Method
413Features: Built-in DC Regulated Power Supply, Control panel not less than 680 x 320 x 480mm, Machine with standard electrical loading arrangement, Machine winding consist of copper for long term service, Machine Conforms to all leading industrial standards with Class “F” Insulation, 2mm x 4mm Heavy Duty Base/Channel with facility to concrete machine, Standard Lovejoy coupler is used to couple machines, Provided with non contact Digital speed measuring equipment, Digital microcontroller based measuring devices with high accuracy and resolution, Inbuilt DC Excitation Unit for field winding of three phase synchronous generator, Front board consist of MS Material with power coating / Epoxy paint to avoid any rust, Specially designed BS10 Terminals and patch cords for electrical safety, Three Phase Supply indication lamps, Earthing screw provided at the back side of the control set-up,Screen Printed diagrammatic representation for the ease of connections.,Product should be provided with protection fuses, colored patch cords, single phase cords, learning manual having theory operating procedure with connecting diagram, FAQ, Glossary, etc, Technical Specifications, Both the machines are flexibly coupled and mounted on a “C” Channel base with suitable interconnection, DC Machine (act as prime mover), Type : Shunt, Make : Alfa / Elmo, Power Rating: 5HP, Voltage Rating: 220VDC ± 10% , Speed : 1500 rpm ± 10%, Insulation: Class ‘F’, Enclosure : SPDP, Duty: Continuous, Mounting : Horizontal Foot Mounted, Shaft Extension : Single Sided, Loading arrangement : Electrical, terminals box: Epoxy paint with terminals and fuses brought out at the top, Machine Base:MS “C” Channel with suitable interconnection, Three Phase Auto-Synchronous AC Machine (Act as generator): Type: Salient type with damper winding, Make : Alfa / Elmo, Power Rating: 3HP, Voltage Rating: 415VAC =± 10%, 50Hz, Configuration : Delta Connected, Rated Current: As per standard, DC Excitation Voltage : 110VDC± 10%, DC Excitation Current : 2A, Speed : 1500 rpm ± 1%, Insulation: Class ‘B/F’, Enclosure : SPDP, DC Excitation Unit: Voltage rating: 350VDC± 10%, Current rating: 2A, Topology: Autotransformer based, DC Power Supply (With overload protection), Mains Supply : 220VAC ± 10%, 50Hz, Output Variable voltage : 0 - 240VDC ± 10% ,Current Rating : 15A, Digital meter (72x72mm)s used, AC Voltmeter: 1 No, AC Ammeter: 1 No, DC Voltmeter: 1 No, DC Ammeter: 2 Nos, Digital Tachometer: Range : 19,999 rpm , Type:Contact / Non-contact, Protection Devices: MCB (DP): 1No (Havells/ Siemens /anchor), Glass Fuse : 3Nos, Grounding Nut: Available at the rear side of the panel, Scope of Learning, To study open circuit characteristic(OCC) of three phase synchronous generator, To study short circuit characteristic (SCC) of three phase synchronous generator, To study short circuit ratio (SCR) of three phase synchronous generator, To study voltage regulation of three phase synchronous generator using MMF method, To study voltage regulation by direct loading, Supporting Accessories supplied with product, Patch Cords of different color scheme, Single Phase Mains Cord, Digital Tachometer, Extra Glass Fuses, Learning Material Manual , Three Phase Resistive Load , Nature of Load: Resistive, Loading Topology: Through toggle switches/MCB’s, Type of Load : Discrete, Single Phase Operation: Voltage : 240V AC/DC ± 10%, 50Hz, Current : 12A, Loading steps : 12 in step of 1A, Three Phase Star Operation : Voltage : 415V AC ± 10%, 50Hz, Current : 4A (each phase), Loading steps : 4 per phase in step of 1A, Three Phase Delta Operation : Voltage: 415V AC ± 10%, 50Hz, Current : 12A (each line), Loading steps : 4 per phase in step of 2.5A (Approx.), Star/Delta Switch: 415V, 25A, Mains MCB :32A (TPN), Mains Indicators:3Nos (for each phase)
414Measurement of Xd & Xq of Three Phase Synchronous Generator Training System
415Features:Built-in DC Regulated Power Supply, Machine with standard electrical loading arrangement, Control panel not less than 680 x 320 x 480mm, Machine winding consist of copperfor long term servic,Machine Conforms to all leading industrial standards with Class “F” Insulation , 2mm x 4mm Heavy Duty Base/Channel with facility to concrete machine, Standard Lovejoy coupler is used to couple machines, Provided with non contact Digital speed measuring equipment, Digital microcontroller based measuring devices with high accuracy and resolution, Front board consist of MS Material with power coating / Epoxy paint to avoid any rust, Specially designed BS10 Terminals and patch cords for electrical safety, Three Phase Supply indication lamps,Earthing screw provided at the back side of the control set-up,Screen Printed diagrammatic representation for the ease of connections.,Product should be provided with protection fuses, colored patch cords, single & three phase cords, learning manual having theory operating procedure with connecting diagram, FAQ, Glossary, etc, Technical Specifications, Both the machines are flexibly coupled and mounted on a “C” Channel base with suitable interconnection, DC Machine (act as Motor), Type : Shunt, Make: Alfa / Elmo, Power Rating: 2HP , Voltage Rating : 20VDC ± 10% , Speed : 1500 rpm ± 10%, Insulation: Class ‘F’, Enclosure : SPDP, Duty : Continuous, Mounting : Horizontal Foot Mounted, Shaft Extension : Single Sided, Loading arrangement : Electrical, Terminals box : Epoxy paint with terminals and fuses brought out at the top, Machine Base :MS “C” Channel with suitable interconnection, Three Phase Auto-Synchronous AC Machine (Act as Motor), Type : Salient type with damper winding, Make: Alfa / Elmo, Power Rating: 3HP, Voltage Rating: 415VAC ± 10%, 50Hz, Configuration : Star Connected, Rated Current: As per standard, DC Excitation Voltage : 110VDC± 10%, DC Excitation Current: 2A, Speed : 1500 rpm ± 2%, Insulation: Class ‘B/F’, Enclosure : SPDP, DC Power Supply (With overload protection) must be separate unit for both the case, Mains Supply : 220VAC ± 10%, 50Hz, Output Variable voltage: 0 - 240VDC ± 10% , Current Rating : 15A, Digital meters (72x72mm) used, AC Voltmeter: 1 No, AC Ammeter: 1 No, DC Voltmeter: 1 No, DC Ammeter: 2 Nos , Digital Tachometer: Range : 19,999 rpm , Type:Contact / Non-contact, Protection Devices: MCB (DP): 1No (Havells/ Siemens /anchor), Glass Fuse : 3Nos, Grounding Nut: Available at the rear side of the panel, Supporting Accessories supplied with product, Patch Cords of different color scheme, Single Phase &Three Phase Mains Cord, Digital Tachometer, Extra Glass Fuses, 8A, Three phase variac, Learning Material Manual.
416Synchronization of Three Phase Synchronous Machine with mains bus bar Training System
417Features: Built-in Separate DC Regulated Power Supply, Machine with standard electrical loading arrangement, Control panel not less than 1200 x 320 x 900mm, Equipped with synchronization lamp method, Built-in DC Excitation Unit for field excitation , Machine winding consist of copper for long term service, Equipped with standard necessary measuring devices such as synchronoscope, phase sequence indicator, Voltmeter, Ammeter, etc, Machine Conforms to all leading industrial standards with Class “F” Insulation, 2mm x 4mm Heavy Duty Base/Channel with facility to concrete machine , Standard Lovejoy coupler is used to couple machines, Provided with contact type Digital speed measuring equipment, Digital microcontroller based measuring devices with high accuracy and resolution, Front board consist of MS Material with power coating to avoid any rust , Specially designed BS10 Terminals and patch cords for electrical safety, Three Phase Supply indication lamps, Earthing screw provided at the back side of the control set-up,Screen Printed diagrammatic representation for the ease of connections., Product should be provided with protection fuses, colored patch cords, single phase cords, learning manual having theory operating procedure with connecting diagram, FAQ, Glossary, etc, Technical Specifications, Both the machines are flexibly coupled and mounted on a “C” Channel base with suitable interconnection, MG Set DC Machine (act as prime mover): Type : Shunt, Make : Alfa / Elmo, Power Rating: 2HP, Voltage Rating : 220VDC ± 10% , Speed : 1500 rpm ± 10%Insulation: Class ‘F’, Enclosure : SPDP, Duty: Continuous, Mounting : Horizontal Foot Mounted, Shaft Extension : Single Sided, Loading arrangement : Electrical, Terminals box : Epoxy paint with terminals and fuses brought out at the top, Machine Base:MS “C” Channel with suitable interconnection, Three Phase Auto-Synchronous AC Machine (Act as generator), Type : Salient type with damper winding, Make : Alfa / Elmo, Power Rating: 3HP, Voltage Rating: 415VAC ± 10%, 50Hz, Configuration: Delta Connected, Rated Current : As per standard, DC Excitation Voltage: 120VDC± 10%, DC Excitation Current: 2A, Speed : 1500 rpm ± 1%, Insulation: Class ‘B/F’, Enclosure : SPDP, DC Excitation Unit, Voltage rating: 350VDC± 10%, Current rating : 2A,Topology : Autotransformer based, DC Power Supply (With overload protection) must be separate unit for both the case, Mains Supply : 220VAC ± 10%, 50Hz, Output Variable voltage : 0 - 240VDC ± 10% , Current Rating : 15A, Digital meter (72x72mm)s used , Phase Sequence Indicator: 1No, Synchronoscope: 1No , DC Voltmeter: 1 No, DC Ammeter: 2 Nos , MFM Meter: 1No, Digital Tachometer: Range : 19,999 rpm , TypeC3+C715:Contact / Non-contact, Three Phase Synchronization Method , Type : Resistive Bulb Type, No. Of Holder : 6Nos. (bulb are exclusive and hence will not be provided), Three Phase Output Indicator: Yes, Protection Devices: MCB (DP) : 1No (Havells/ Siemens /anchor), MCB (TPN): 1No (Havells/ Siemens /anchor), Glass Fuse : 6Nos, Grounding Nut: Available at the rear side of the panel, Scope of Learning:, Synchronization of Three Phase Alternators with mains bus bar at no load condition by , Synchronoscope Method, Three dark lamps Method, Two bright one dark lamp Method, Study of Open Circuit characteristic of Three Phase Alternator, Study of Short Circuit characteristic of Three Phase Alternator, Study of regulation of Three Phase Alternator by Synchronous Impedance Method, Supporting Accessories supplied with product, Patch Cords of different color scheme, Single Phase &Three Phase Mains Cord, Digital Tachometer, Extra Glass Fuses, Learning Material Manual
418Parallel Operation of Two Three Phase Synchronous Machine Training System
419Features: Built-in Separate DC Regulated Power Supply, Control panel not less than 1200 x 320 x 900mm, Machine with standard electrical loading arrangement, Equipped with synchronization lamp method, Built-in DC Excitation Unit for field excitation, Machine winding consist of copper for long term service, Equipped with standard necessary measuring devices such as synchronoscope, phase sequence indicator, Voltmeter, Ammeter, etc, Machine Conforms to all leading industrial standards with Class “F” Insulation, 2mm x 4mm Heavy Duty Base/Channel with facility to concrete machine , Standard Lovejoy coupler is used to couple machines, Provided with contact type Digital speed measuring equipment, Digital microcontroller based measuring devices with high accuracy and resolution, Front board consist of MS Material with power coating to avoid any rust, Specially designed BS10 Terminals and patch cords for electrical safety, Three Phase Supply indication lamps, Earthing screw provided at the back side of the control set-up, Screen Printed diagrammatic representation for the ease of connections., Product should be provided with protection fuses, colored patch cords, single phase cords, learning manual having theory operating procedure with connecting diagram, FAQ, Glossary, etc, Technical Specifications: Both the machines are flexibly coupled and mounted on a “C” Channel base with suitable interconnection, MG Set (2Nos.), DC Machine (act as prime mover), Type : Shunt, Make : Alfa / Elmo, Power Rating: 2HP, Voltage Rating : 220VDC ± 10% , Speed : 1500 rpm ± 10%, Insulation: Class ‘F’, Enclosure : SPDP, Duty: Continuous, Mounting : Horizontal Foot Mounted, Shaft Extension : Single Sided, Loading arrangement : Electrical, Terminals box: Powder Coated with terminals and fuses brought out at the top, Machine Base: MS “C” Channel with suitable interconnection, Three Phase Auto-Synchronous AC Machine (Act as generator): Type : Salient type with damper winding, Make : Alfa / Elmo, Power Rating: 3HP, Voltage Rating : 415VAC ± 10%, 50Hz, Configuration : Delta Connected, Rated Current : As per standard, DC Excitation Voltage : 120VDC± 10%, DC Excitation Current: 2A, Speed : 1500 rpm ± 1%, Insulation: Class ‘B/F’, Enclosure : SPDP, DC Excitation Unit (2nos.), Voltage rating : 350VDC± 10%, Current rating: 2A, Topology: Autotransformer based, DC Power Supply (With overload protection) must be separate unit for both the case, Mains Supply : 220VAC ± 10%, 50Hz, Output Variable voltage: 0 - 240VDC ± 10% , Current Rating : 15A, Digital meter (72x72mm)s used, AC MFM Meter : 2 Nos , Phase Sequence Indicator : 1No, Synchronoscope : 1No , DC Voltmeter: 2 Nos, DC Ammeter: 4 Nos , Digital Tachometer: Range : 19,999 rpm , Type:Contact / Non-contact, Three Phase Synchronization Method : Type: Resistive Bulb Type , No. Of Holder: 6Nos. (bulbs are exclusive and hence will not be provided), Three Phase Output Indicator : Yes, Protection Devices, MCB (DP): 2Nos (Havells/ Siemens /anchor), MCB (TPN) : 1No (Havells/ Siemens /anchor), Glass Fuse: 12Nos, Grounding Nut: Available at the rear side of the panel, Scope of Learning: Study and Synchronization of two Three Phase Alternators by Synchronoscope Method at no load, Study and Synchronization of two Three Phase Alternators, by three dark lamps Method at no load, Study and Synchronization of two Three Phase Alternators, by two bright one dark lamp Method at no load , Study of Open Circuit characteristic of Three Phase Alternator, Study of Short Circuit characteristic of Three Phase Alternator, Study of Short Circuit Ratio of Three Phase Alternator, Study of regulation of Three Phase Alternator by Synchronous Impedance Method at no load, Supporting Accessories supplied with product, Patch Cords of different color scheme, Single Phase &Three Phase Mains Cord, Digital Tachometer, Extra Glass Fuses, Learning Material Manual
420AC Starter Training System
421Features: Dital microcontroller based measuring devices with high accuracy and resolution, Control panel not less than 680 x 320 x 480mm, Control board Consist of MS Material with power coating / Epoxy paint to avoid any rust, Screen printed symbols, circuit diagrams, graphics or photos wherever requires, Designed using standard BS-10 terminal and patch cords for electrical safety, Machine windingconsist of copper for long term service,Machine with Class “F” Insulation, Machine with standard mechanical loading structure, Machine with standard tabular spring balance with zero adjustment facility ,1.5 mm x 3mm Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts,Brake-Drum/Pulley with heat suppression facility inside it,Provided with non contact Digital speed measuring equipment, Equipped with three phase supply indicator lamps, Earthing screw provided at the back side of the control board, Product supplied with protection fuses, colored patch cords, single and three phase cords, learning manual having theory operating procedure with connecting diagram, FAQ, Glossary, etc , Technical Specifications, Mains Supply : 415VAC ±10%, 50Hz, Star Delta Starter, Make : Siemens/L&T or equivalent, Power Rating : 5HP (not available below this rating), Three Phase DOL Starter, Make: Siemens/L&T or equivalent, Power Rating : 3HP, Single Phase DOL Starter , Make: Siemens/L&T or equivalent, Power Rating : 1HP, Digital meter (72x72mm)s used, AC Voltmeter: 500V., AC Ammeter : 10A., Digital Tachometer, Range : 19,999 rpm , Type :Contact / Non-contact, Protection Devices, MCB (TPN): 1No (Havells/ Siemens /anchor), Glass Fuse : 3Nos, Grounding Nut : Available at the rear side of the panel, Three Phase Induction Motor, Type : Squirrel Cage, Rating : 1HP , Voltage Rating : 415V ±10%, 50Hz, Current Rating: As per standard, Speed : 1440 RPM ±10%, Insulation: Class ‘F’, Duty: Continuous, Enclosure : TEFC, Mounting: Horizontal Foot Mounted, Shaft Extension : Single Sided, Loading arrangement : Mechanical , Brake Drum/Pulley : MS/Aluminum Casted with heat suppression facility inside it, Spring Balance: 2Nos. (Salter make), Loading Nut & Bolts : Brass material, Terminals box : Epoxy paint with terminals and fuses brought out at the top, Machine Base:MS “C” Channel with suitable interconnection, single Phase Induction Motor: Type : Capacitor type Squirrel Cage, Make: SEMENS/HAVELLS, Rating: 1HP , Voltage Rating : 220V ±10%, 50Hz, Current Rating: As per standard, Speed : 1440 RPM ±10%, Insulation : Class ‘F’, Duty : Continuous, Enclosure : TEFC, Mounting : Horizontal Foot Mounted, Shaft Extension : Single Sided, Loading arrangement : Mechanical , Brake Drum/Pulley : MS/Aluminum Casted with heat suppression facility inside it, Spring Balance: 2Nos. (Salter make), Loading Nut & Bolts: Brass material, Terminals box : Epoxy paint with terminals and fuses brought out at the top, Machine Base:MS “C” Channel with suitable interconnection, Scope of Learning, Study of Star Delta Starter and its applications, Study of DOL Starter and its application, Supporting Accessories supplied with product, extra Glass Fuses, Digital Tachometer, 8A Three phase autotransformer.
422Universal Motor Training System
423Features: Machine with standard mechanical loading structure, Control panel not less than 680 x 320 x 480mm, Machine with standard tabular spring balance with zero adjustment facility, Machine winding consist of copper for long term service, Machine Conforms to all leading industrial standards with Class “F” Insulation, Brake-Drum/Pulley (Aluminum or MS Casting) with heat suppression facility inside it, Provided with non contact/contact type Digital speed measuring equipment, Inbuilt DC Power Drive of suitable rating with overload protection, Inbuilt Single phase Auto-Transformer for its operation in AC Mode, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts , Control panel with digital microcontroller based measuring devices with high accuracy and resolution, Front board consist of MS Material with power coating / epoxy paint to avoid any rust, Provided with suitable protection such as fuses, MCB, etc wherever requires, Specially designed BS10 Terminals and patch cords for electrical safety, Lamp indication for single phase supply, Screen printed diagrammatic representation for the ease of connections.,Productprovide with protection fuses, colored patch cords, single phase cords, learning manual contents having theory, operating procedure with connecting diagram, FAQ, Glossary, etc, Technical Specifications: Operation Voltage of Control Panel : 220VAC ± 10%, 50Hz, DC Machine, Type : Universal, Make : Alfa / Elmo, Power Rating : 1HP , Voltage Rating : 220VAC & DC ± 10% , Speed : 1500 rpm ± 10% at load, Insulation: Class ‘F’, Winding: Copper, Duty: Continuous, Enclosure : SPDP, Mounting : Horizontal foot mounted, Shaft Extension: Single Sided, Loading arrangement : Mechanical , Brake Drum/Pulley : MS/Aluminum Casted with heat suppression facility inside it, Spring Balance: 2Nos. (Salter make), Loading Nut & Bolts: Brass material, Terminals box : Powder coated/epoxy paint with terminals and fuses brought out at the top, Machine Base:MS “C” Channel with suitable interconnection, Digital meters (72x72mm) used, DC Voltmeter: 300V, DC Ammeter: 20A , AC Voltmeter: 500V, AC Ammeter: 10A , DC Power Supply: Output Fixed voltage : 200VDC ± 10% , Output Variable voltage : 0 - 240VDC ± 10% , Current Rating : Based on Power Rating of Machine, Protection : Overload Protection, AC Variable Source : Output Variable Voltage: 0 - 240VAC ± 10%, Current Rating : Based on Power Rating of Machine: Digital Tachometer : Range : 19,999 rpm , Type:Contact / Non-contact, Protection Devices: MCB (DP): 1No (Havells/ Siemens /anchor), Glass Fuse : 3Nos., Grounding Nut : Available at the rear side of the panel, Scope of Learning, Study about Universal Motor with following topics., Understanding fundamentals and operational working principles , Running and reversing phenomenon , Performance at load condition (load test) in AC Mode and correspondingly plot a graph between measured electrical parameters such as, current, voltage, torque (by calculation), speed, etc., Performance at load condition (load test) in DC Mode and correspondingly plot a graph between measured electrical parameters such as, current, voltage, torque (by calculation), speed, etc., Supporting Accessories supplied with Control Setup, Patch Cords of different color scheme, Single Phase Mains Cord, Extra Glass Fuses, Digital Tachometer, Learning Material Manual
424PMDC Motor Training System
425Features: Machine with standard mechanical loading structure, Control panel not less than 680 x 320 x 480mm, Machine with standard tabular spring balance with zero adjustment facility, Machine winding consist of copper for long term service Machine Conforms to all leading industrial standards with Class “F” Insulation,Brake-Drum/Pulley (Aluminum or MS Casting) with heat suppression facility inside it, Provided with non contact/contact type Digital speed measuring equipment, Inbuilt DC Power Drive of suitable rating with overload protection,Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts, Control panel with digital microcontroller based measuring devices with high accuracy and resolution, Front board consist of MS Material with power coating / epoxy paint to avoid any rust, Provided with suitable protection such as fuses, MCB, etc wherever requires, Specially designed BS10 Terminals and patch cords for electrical safety, Lamp indication for single phase supply, Screen printed diagrammatic representation for the ease of connections., Productprovide with protection fuses, colored patch cords, single phase cords, learning manual contents having theory, operating procedure with connecting diagram, FAQ, Glossary, etc, Technical Specifications: Operation Voltage of Control Panel : 220VAC ± 10%, 50Hz, DC Machine: Type : PMDC, Power Rating : 1HP , Make : Alfa / Elmo or equivalent, Voltage Rating : 220VDC ± 10% , Speed: 1500 rpm ± 10%, Insulation: Class ‘F’, Winding: Copper, Duty : Continuous, Enclosure : SPDP, Mounting : Horizontal foot mounted, Shaft Extension : Single Sided, Loading arrangement : Mechanical , Brake Drum/Pulley : MS/Aluminum Casted with heat suppression facility inside it, Spring Balance : 2Nos. (Salter make), Loading Nut & Bolts : Brass material, Terminals box: Powder coated/epoxy paint with terminals and fuses brought out at the top, Machine Base :MS “C” Channel with suitable interconnection, Digital meters (72x72mm) used, DC Voltmeter: 300V, DC Ammeter: 20A , DC Power Supply (with field failure, overload protection, must be operated at pmdc and shunt mode), Mains Supply : 220VAC ± 10%, 50Hz, Output Variable voltage : 0 - 240VDC ± 10% , Current Rating : 12A, Digital Tachometer: Range : 19,999 rpm , Type :Contact / Non-contact, Protection Devices, MCB (DP): 1No(Havells/ Siemens /anchor), Glass Fuse : 3Nos., Grounding Nut : Available at the rear side of the panel, Scope of Learning: Study of no load characteristic of PMDC Motor, Study of Load Characteristic of PMDC Motor, Supporting Accessories supplied with Control Setup, Patch Cords of different color scheme, Single Phase Mains Cord, Extra Glass Fuses, Digital Tachometer, Learning Material Manual
426DC Shunt Wound Motor Training System
427Features: Machine with standard mechanical loading structure, Machine with standard tabular spring balance with zero adjustment facility , Machine winding consist of copper for long term service, Control panel not less than 680 x 320 x 480mm, Machine Conforms to all leading industrial standards with Class “F” Insulation, Brake-Drum/Pulley (Aluminum or MS Casting) with heat suppression facility inside it, Provided with non contact/contact type Digital speed measuring equipment, Inbuilt DC Power Drive of suitable rating with overload protection, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts , Control panel with digital microcontroller based measuring devices with high accuracy and resolution, Front board consist of MS Material with power coating / epoxy paint to avoid any rust , Provided with suitable protection such as fuses, MCB, etc wherever requires, Specially designed BS10 Terminals and patch cords for electrical safety, Lamp indication for single phase supply, Screen printed diagrammatic representation for the ease of connections.,Productprovide with protection fuses, colored patch cords, single phase cords, learning manual contents having theory, operating procedure with connecting diagram, FAQ, Glossary, etc, Technical Specifications, Operation Voltage of Control Panel: 220VAC ± 10%, 50Hz, DC Machine: Type : Shunt, Power Rating : 1HP , Make : Alfa / Elmo, Voltage Rating : 220VDC ± 10% , Field Excitation : 200VDC ± 10%, Speed : 1500 rpm ± 10%, Insulation: Class ‘F’, Winding : Copper, Duty: Continuous, Enclosure : SPDP, Mounting : Horizontal foot mounted, Shaft Extension : Single Sided, Loading arrangement : Mechanical , Brake Drum/Pulley : MS/Aluminum Casted with heat suppression facility inside it, Spring Balance : 2Nos. (Salter make), Loading Nut & Bolts : Brass material, Terminals box : Powder coated/epoxy paint with terminals and fuses brought out at the top, Machine Base :MS “C” Channel with suitable interconnection, Digital meter (72x72mm) used, DC Voltmeter: 300V, DC Ammeter : 20A (2 nos) , DC Power Supply (with field failure, overload protection, must be operated at pmdc and shunt mode), Mains Supply: 220VAC ± 10%, 50Hz, Output Variable voltage: 0 - 240VDC ± 10% , Current Rating: 15A, Digital Tachometer : Range : 19,999 rpm , Type:Contact / Non-contact, Protection Devices, MCB (DP) : 1No(Havells/ Siemens /anchor), Glass Fuse : 3Nos., Grounding Nut: Available at the rear side of the panel, Scope of Learning,Running and reversing phenomenon, Study of self excited DC Shunt Motor, Study of Separately Excited DC Shunt Motor, Study of no load characteristic of DC Shunt Motor, Study of Load Characteristic of DC Shunt Motor, Speed Control of DC Shunt Motor by Field Current control Method, Speed Control of DC Shunt Motor by Armature Voltage Control method, Supporting Accessories supplied with Control Setup, Patch Cords of different color scheme, Single Phase Mains Cord, Extra Glass Fuses, Digital Tachometer, Learning Material Manual, Optional Accessories (User need to quote these separately), Rheostat, 2.8A, 400Ohms
428DC Series Wound Motor Training System
429Features: Machine with standard mechanical loading structure, Machine with standard tabular spring balance with zero adjustment facility , Machine winding consist of copper for long term service, Control panel not less than 680 x 320 x 480mm, Machine Conforms to all leading industrial standards with Class “F” Insulation, Brake-Drum/Pulley (Aluminum or MS Casting) with heat suppression facility inside it, Provided with non contact/contact type Digital speed measuring equipment, Inbuilt DC Power Drive of suitable rating with overload protection, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts , Control panel with digital microcontroller based measuring devices with high accuracy and resolution, Front board consist of MS Material with power coating / epoxy paint to avoid any rust , Provided with suitable protection such as fuses, MCB, etc wherever requires, Specially designed BS10 Terminals and patch cords for electrical safety, Lamp indication for single phase supply, Screen printed diagrammatic representation for the ease of connections.,Productprovide with protection fuses, colored patch cords, single phase cords, learning manual contents having theory, operating procedure with connecting diagram, FAQ, Glossary, etc, Technical Specifications, Operation Voltage of Control Panel: 220VAC ± 10%, 50Hz, DC Machine: Type : Series, Power Rating : 1HP , Make : Alfa / Elmo, Voltage Rating : 220VDC ± 10% , Field Excitation : 200VDC ± 10%, Speed : 1500 rpm ± 10%, Insulation: Class ‘F’, Winding : Copper, Duty: Continuous, Enclosure : SPDP, Mounting : Horizontal foot mounted, Shaft Extension : Single Sided, Loading arrangement : Mechanical , Brake Drum/Pulley : MS/Aluminum Casted with heat suppression facility inside it, Spring Balance : 2Nos. (Salter make), Loading Nut & Bolts : Brass material, Terminals box : Powder coated/epoxy paint with terminals and fuses brought out at the top, Machine Base :MS “C” Channel with suitable interconnection, Digital meter (72x72mm) used, DC Voltmeter: 300V, DC Ammeter : 20A (2 nos) , DC Power Supply (with field failure, overload protection, must be operated at pmdc and shunt mode), Mains Supply: 220VAC ± 10%, 50Hz, Output Variable voltage: 0 - 240VDC ± 10% , Current Rating: 15A, Digital Tachometer : Range : 19,999 rpm , Type:Contact / Non-contact, Protection Devices, MCB (DP) : 1No(Havells/ Siemens /anchor), Glass Fuse : 3Nos., Grounding Nut: Available at the rear side of the panel, Scope of Learning, Running and reversing phenomenon, Study of self excited DC Series Motor, Study of Load Characteristic of DC Series Motor, Speed Control of DC Series Motor by Field Current control Method, Speed Control of DC Series Motor by Armature Voltage Control method, Supporting Accessories supplied with Control Setup, Patch Cords of different color scheme, Single Phase Mains Cord, Extra Glass Fuses, Digital Tachometer, Learning Material Manual , Optional Accessories (User need to quote these separately), Rheostat, 2.8A, 400Ohms
430DC Compound Wound Motor Training System
431Features: Machine with standard mechanical loading structure, Machine with standard tabular spring balance with zero adjustment facility , Machine winding consist of copper for long term service, Control panel not less than 680 x 320 x 480mm, Machine Conforms to all leading industrial standards with Class “F” Insulation, Brake-Drum/Pulley (Aluminum or MS Casting) with heat suppression facility inside it, Provided with non contact/contact type Digital speed measuring equipment, Inbuilt DC Power Drive of suitable rating with overload protection, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts , Control panel with digital microcontroller based measuring devices with high accuracy and resolution, Front board consist of MS Material with power coating / epoxy paint to avoid any rust , Provided with suitable protection such as fuses, MCB, etc wherever requires, Specially designed BS10 Terminals and patch cords for electrical safety, Lamp indication for single phase supply, Screen printed diagrammatic representation for the ease of connections.,Productprovide with protection fuses, colored patch cords, single phase cords, learning manual contents having theory, operating procedure with connecting diagram, FAQ, Glossary, etc, Technical Specifications, Operation Voltage of Control Panel: 220VAC ± 10%, 50Hz, DC Machine: Type : Compound, Power Rating : 1HP , Make : Alfa / Elmo, Voltage Rating : 220VDC ± 10% , Field Excitation : 200VDC ± 10%, Speed : 1500 rpm ± 10%, Insulation: Class ‘F’, Winding : Copper, Duty: Continuous, Enclosure : SPDP, Mounting : Horizontal foot mounted, Shaft Extension : Single Sided, Loading arrangement : Mechanical , Brake Drum/Pulley : MS/Aluminum Casted with heat suppression facility inside it, Spring Balance : 2Nos. (Salter make), Loading Nut & Bolts : Brass material, Terminals box : Powder coated/epoxy paint with terminals and fuses brought out at the top, Machine Base :MS “C” Channel with suitable interconnection, Digital meter (72x72mm) used, DC Voltmeter: 300V, DC Ammeter : 20A (2 nos) , DC Power Supply (with field failure, overload protection, must be operated at pmdc and shunt mode), Mains Supply: 220VAC ± 10%, 50Hz, Output Variable voltage: 0 - 240VDC ± 10% , Current Rating: 15A, Digital Tachometer : Range : 19,999 rpm , Type:Contact / Non-contact, Protection Devices, MCB (DP) : 1No(Havells/ Siemens /anchor), Glass Fuse : 3Nos., Grounding Nut: Available at the rear side of the panel, Scope of Learning, Running and reversing phenomenon, Study ofload characteristic of differential long shunt DC Compound Motor, Study ofload characteristics of differential short shunt DC Compound Motor, Supporting Accessories supplied with Control Setup, Patch Cords of different color scheme, Single Phase Mains Cord, Extra Glass Fuses, Digital Tachometer, Learning Material Manual
432DC Shunt Motor Shunt Generator Training System
433Features: Machine with standard electrical loading arrangement through flexible love-joy coupler, Machine winding consist of copper for long term service, Machine Conforms to all leading industrial standards with Class “B/F” Insulation , Control panel not less than 680 x 320 x 480mm, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts, Provided with non contact/contact type Digital speed measuring equipment, Inbuilt DC Power Drive of suitable rating with overload protection, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts , Control panel with digital microcontroller based measuring devices with high accuracy and resolution, Front board consist of MS Material with power coating / epoxy paint to avoid any rust , Provided with suitable protection such as fuses, MCB, etc wherever requires, Specially designed BS10 Terminals and patch cords for electrical safety, Lamp indication for single phase supply, Screen printed diagrammatic representation for the ease of connections.,Productprovide with protection fuses, colored patch cords, single phase cords, learning manual contents having theory, operating procedure with connecting diagram, FAQ, Glossary, etc,Technical Specifications, Operation Voltage of Control Panel : 220VAC ± 10%, 50Hz, Machine Specifications : Both the machines are flexibly coupled and mounted on a “C” Channel base, DC Machine (Act as prime mover): Type : Shunt, Make : Alfa / Elmo, Voltage Rating : 220VDC ± 10%, Speed : 1500 rpm ± 10% at load, Insulation: Class ‘F’,Winding: Copper, Duty: Continuous, Enclosure : SPDP, Mounting : Horizontal foot mounted, Shaft Extension: Single Sided, Loading arrangement : Electrical, DC Machine (Act as generator), Type : Shunt, Make : Alfa / Elmo, Rating : 1 HP , Generated Voltage Rating: 220VDC ± 10% at load, Speed : 1500 rpm ± 10%, Insulation: Class ‘F’, Winding : Copper, Duty: Continuous, Enclosure : SPDP, Terminals box : Powder coated/epoxy paint with terminals and fuses brought out at the top, Machine Base:MS “C” Channel with suitable interconnection, Digital meter (72x72mm)s used, DC Voltmeter: 300V (2nos), DC Ammeter: 20A (3nos) , DC Power Supply (with field failure, overload protection, must be operated at pmdc and shunt mode), Mains Supply : 220VAC ± 10%, 50Hz, Output Variable voltage : 0 - 240VDC ± 10% , Current Rating : 15A, Digital Tachometer: Range : 19,999 rpm , Type:Contact / Non-contact, Protection Devices, MCB (DP): 1No, Glass Fuse : 3Nos, Grounding Nut : Available at the rear side of the panel, Scope of Learning: Study of Separately Excited DC Shunt Generator , Study of Self Excited DC Shunt Generator , Study of No Load Characteristics of Self Excited DC Shunt Generator, Study of (Internal and External) Load Characteristics of Self Excited DC Shunt Generator : Supporting Accessories supplied with Control Setup, Patch Cords of different color scheme, Single Phase Mains Cord, Extra Glass Fuses, Digital Tachometer, Learning Material Manual , Optional Accessories (User need to quote these separately), Rheostat, 2.8A, 400Ohms, Resistive Load , Nature of Load: Resistive, Loading Topology: Through toggle switches/MCB’s, Type of Load : Discrete, Single Phase Operation: Voltage : 240V AC/DC ± 10%, 50Hz, Current : 12A , Loading steps : 12 in step of 1A, Three Phase Star Operation , Voltage : 415V AC ± 10%, 50Hz, Current : 4A (each phase), Loading steps : 4 per phase in step of 1A, Three Phase Delta Operation :Voltage: 415V AC ± 10%, 50Hz, Current : 12A (each line), Loading steps : 4 per phase in step of 2.5A (Approx.), Star/Delta Switch: 415V, 25A, Mains MCB :32A (TPN) (Havells/ Siemens /anchor), Mains Indicators:3Nos (for each phase).
434DC Shunt Motor Series Generator Training System
435Features: Machine with standard electrical loading arrangement through flexible love-joy coupler, Machine winding consist of copper for long term service, Machine Conforms to all leading industrial standards with Class “B/F” Insulation , Control panel not less than 680 x 320 x 480mm, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts, Provided with non contact/contact type Digital speed measuring equipment, Inbuilt DC Power Drive of suitable rating with overload protection, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts , Control panel with digital microcontroller based measuring devices with high accuracy and resolution, Front board consist of MS Material with power coating / epoxy paint to avoid any rust , Provided with suitable protection such as fuses, MCB, etc wherever requires, Specially designed BS10 Terminals and patch cords for electrical safety, Lamp indication for single phase supply, Screen printed diagrammatic representation for the ease of connections.,Productprovide with protection fuses, colored patch cords, single phase cords, learning manual contents having theory, operating procedure with connecting diagram, FAQ, Glossary, etc,Technical Specifications,Machine Specifications : Both the machines are flexibly coupled and mounted on a “C” Channel base, DC Machine (Act as prime mover): Type : Shunt, Make : Alfa / Elmo, Voltage Rating : 220VDC ± 10%, Speed : 1500 rpm ± 10% at load, Insulation: Class ‘F’,Winding: Copper, Duty: Continuous, Enclosure : SPDP, Mounting : Horizontal foot mounted, Shaft Extension: Single Sided, Loading arrangement : Electrical, DC Machine (Act as generator), Type : Series, Make : Alfa / Elmo, Rating : 1 HP , Generated Voltage Rating: 220VDC ± 10% at load, Speed : 1500 rpm ± 10%, Insulation: Class ‘F’, Winding : Copper, Duty: Continuous, Enclosure : SPDP, Terminals box : Powder coated/epoxy paint with terminals and fuses brought out at the top, Machine Base:MS “C” Channel with suitable interconnection, Digital meter (72x72mm)s used, DC Voltmeter: 300V (2nos), DC Ammeter: 20A (3nos) , DC Power Supply (with field failure, overload protection, must be operated at pmdc and shunt mode), Mains Supply : 220VAC ± 10%, 50Hz, Output Variable voltage : 0 - 240VDC ± 10% , Current Rating : 15A, Digital Tachometer: Range : 19,999 rpm , Type:Contact / Non-contact, Protection Devices, MCB (DP): 1No, Glass Fuse : 3Nos, Grounding Nut : Available at the rear side of the panel, Scope of Learning: Study of No Load Characteristics of Self Excited DC Series Generator, Study of Load Characteristics of Self Excited DC Series Generator Supporting Accessories supplied with Control Setup, Patch Cords of different color scheme, Single Phase Mains Cord, Extra Glass Fuses, Digital Tachometer, Learning Material Manual , Optional Accessories (User need to quote these separately), Resistive Load , Nature of Load: Resistive, Loading Topology: Through toggle switches/MCB’s, Type of Load : Discrete, Single Phase Operation: Voltage : 240V AC/DC ± 10%, , Current : 12A , Loading steps : 12 in step of 1A, Three Phase Star Operation : Voltage : 415V AC ± 10%, 50Hz, Current : 4A (each phase), Loading steps : 4 per phase in step of 1A, Three Phase Delta Operation , Voltage : 415V AC ± 10%, 50Hz, Current : 12A (each line), Loading steps : 4 per phase in step of 2.5A (Approx.), Star/Delta Switch: 415V, 25A, Mains MCB :32A (TPN) (Havells/ Siemens /anchor), Mains Indicators:3Nos (for each phase).
436DC Shunt Motor Compound Generator Training System
437Features: Machine with standard electrical loading arrangement through flexible love-joy coupler, Machine winding consist of copper for long term service, Machine Conforms to all leading industrial standards with Class “B/F” Insulation , Control panel not less than 680 x 320 x 480mm, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts, Provided with non contact/contact type Digital speed measuring equipment, Inbuilt DC Power Drive of suitable rating with overload protection, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts , Control panel with digital microcontroller based measuring devices with high accuracy and resolution, Front board consist of MS Material with power coating / epoxy paint to avoid any rust , Provided with suitable protection such as fuses, MCB, etc wherever requires, Specially designed BS10 Terminals and patch cords for electrical safety, Lamp indication for single phase supply, Screen printed diagrammatic representation for the ease of connections., Productprovide with protection fuses, colored patch cords, single phase cords, learning manual contents having theory, operating procedure with connecting diagram, FAQ, Glossary, etc,Technical Specifications, Machine Specifications : Both the machines are flexibly coupled and mounted on a “C” Channel base, DC Machine (Act as prime mover): Type : Shunt, Make : Alfa / Elmo, Voltage Rating : 220VDC ± 10%, Speed : 1500 rpm ± 10% at load, Insulation: Class ‘F’, Winding: Copper, Duty: Continuous, Enclosure : SPDP, Mounting : Horizontal foot mounted, Shaft Extension: Single Sided, Loading arrangement : Electrical, DC Machine (Act as generator), Type : Compound, Make : Alfa / Elmo, Rating : 1 HP , Generated Voltage Rating: 220VDC ± 10% at load, Speed : 1500 rpm ± 10%, Insulation: Class ‘F’, Winding : Copper, Duty: Continuous, Enclosure : SPDP, Terminals box : Powder coated/epoxy paint with terminals and fuses brought out at the top, Machine Base:MS “C” Channel with suitable interconnection, Digital meter (72x72mm)s used, DC Voltmeter: 300V (2nos), DC Ammeter: 20A (3nos) , DC Power Supply (with field failure, overload protection, must be operated at pmdc and shunt mode), Mains Supply : 220VAC ± 10%, 50Hz, Output Variable voltage : 0 - 240VDC ± 10% , Current Rating : 15A, Digital Tachometer: Range : 19,999 rpm , Type:Contact / Non-contact, Protection Devices, MCB (DP): 1No, Glass Fuse : 3Nos, Grounding Nut : Available at the rear side of the panel, Scope of Learning: Study ofDC Compound Generator, Study Load Characteristics of Short Shunt DC Compound Generator, Study Load Characteristics of Long Shunt DC Compound Generator, Study Load Characteristics of Cumulative DC Compound Generator, Study Load Characteristics of Differential DC Compound Generator, Supporting Accessories supplied with Control Setup, Patch Cords of different color scheme, Single Phase Mains Cord, Extra Glass Fuses, Digital Tachometer, Learning Material Manual , Optional Accessories (User need to quote these separately), Resistive Load , Nature of Load: Resistive, Loading Topology: Through toggle switches/MCB’s, Type of Load : Discrete, Single Phase Operation: Voltage : 240V AC/DC ± 10%, , Current : 12A , Loading steps : 12 in step of 1A, Three Phase Star Operation : Voltage : 415V AC ± 10%, 50Hz, Current : 4A (each phase), Loading steps : 4 per phase in step of 1A, Three Phase Delta Operation , Voltage : 415V AC ± 10%, 50Hz, Current : 12A (each line), Loading steps : 4 per phase in step of 2.5A (Approx.), Star/Delta Switch: 415V, 25A, Mains MCB :32A (TPN) (Havells/ Siemens /anchor), Mains Indicators:3Nos (for each phase)
438Three Phase Induction Motor DC Shunt Generator Training System
439Features: Machine with standard electrical loading arrangement through flexible love-joy coupler, Machine winding consist of copper for long term service, Machine Conforms to all leading industrial standards with Class “B/F” Insulation , Control panel not less than 680 x 320 x 480mm, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts, Provided with non contact/contact type Digital speed measuring equipment, Inbuilt DC Power Drive of suitable rating with overload protection, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts , Control panel with digital microcontroller based measuring devices with high accuracy and resolution, Front board consist of MS Material with power coating / epoxy paint to avoid any rust , Provided with suitable protection such as fuses, MCB, etc wherever requires, Specially designed BS10 Terminals and patch cords for electrical safety, Three Phase Supply indication lamps, Inbuilt AC DOL Starter which start and protect the machine from overload condition, Earthing screw provided at the back side of the control set-up, Screen printed diagrammatic representation for the ease of connections.,Productprovide with protection fuses, colored patch cords, single phase cords, learning manual contents having theory, operating procedure with connecting diagram, FAQ, Glossary, etc, Technical Specifications Operation Voltage of Control Panel : 415VAC ± 10%, 50Hz Auxiliary Supply of Control Panel : 230VAC ± 10%, 50Hz Machine Specifications : Both the machines are flexibly coupled and mounted on a “C” Channel base, AC Machine (Act as prime mover), Type : Three Phase squirrel cage induction motor, Make: Havells / Siemens / L&T, Voltage Rating: 415VAC ± 10%, 50Hz, Speed : 1440 rpm ± 10%, Insulation: Class ‘F’, Winding: Copper, Duty: Continuous, Enclosure: TEFC, Mounting : Horizontal foot mounted, Shaft Extension: Single Sided, Loading arrangement : Electrical, DC Machine (Act as generator): Type : Shunt, Make: Alfa / Elmo, Rating : 1 HP, Generated Voltage Rating: 220VDC ± 10% at load, Speed : 1500 rpm ± 10%, Insulation : Class ‘F’, Winding : Copper, Duty: Continuous, Enclosure : SPDP, Terminals box: Powder coated/epoxy paint with terminals and fuses brought out at the top, Machine Base:MS “C” Channel with suitable interconnection, Digital meters (72x72mm) used: AC Voltmeter: 500V, AC Ammeter: 10A , DC Voltmeter: 300V, DC Ammeter: 20A , AC Starter: Type: DOL Starter (L&T / Siemens Make), Digital Tachometer, Range : 19,999 rpm , Type:Contact / Non-contact, Protection Devices: Glass Fuse : 3Nos, Grounding Nut : Available at the rear side of the panel, Scope of Learning, Study of No Load Characteristics of Self Excited DC Shunt Generator,Study of (Internal and External) Load Characteristics of Self Excited DC Shunt Generator : Supporting Accessories supplied with Control Setup, Patch Cords of different color scheme, Single Phase Mains Cord, Extra Glass Fuses,Digital Tachometer,Learning Material Manual , Optional Accessories (User need to quote these separately),Resistive Load , Nature of Load: Resistive, Loading Topology: Through toggle switches/MCB’s, Type of Load : Discrete , Single Phase Operation: Voltage: 240V AC/DC ± 10%, 50Hz, Current : 12A , Loading steps : 12 in step of 1A, Three Phase Star Operation : Voltage : 415V AC ± 10%, 50Hz, Current : 4A (each phase), Loading steps : 4 per phase in step of 1A, Three Phase Delta Operation : Voltage : 415V AC ± 10%, 50Hz, Current : 12A (each line), Loading steps : 4 per phase in step of 2.5A (Approx.), Star/Delta Switch: 415V, 25A, Mains MCB :32A (TPN) (Havells/ Siemens /anchor), Mains Indicators:3Nos (for each phase)
440Three Phase Induction Motor DC Series Generator Training System
441Features: Machine with standard electrical loading arrangement through flexible love-joy coupler, Machine winding consist of copper for long term service, Machine Conforms to all leading industrial standards with Class “B/F” Insulation , Control panel not less than 680 x 320 x 480mm, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts, Provided with non contact/contact type Digital speed measuring equipment, Inbuilt DC Power Drive of suitable rating with overload protection, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts , Control panel with digital microcontroller based measuring devices with high accuracy and resolution, Front board consist of MS Material with power coating / epoxy paint to avoid any rust , Provided with suitable protection such as fuses, MCB, etc wherever requires, Specially designed BS10 Terminals and patch cords for electrical safety, Three Phase Supply indication lamps, Inbuilt AC DOL Starter which start and protect the machine from overload condition, Earthing screw provided at the back side of the control set-up, Screen printed diagrammatic representation for the ease of connections.,Productprovide with protection fuses, colored patch cords, single phase cords, learning manual contents having theory, operating procedure with connecting diagram, FAQ, Glossary, etc, Technical Specifications Operation Voltage of Control Panel : 415VAC ± 10%, 50Hz Auxiliary Supply of Control Panel : 230VAC ± 10%, 50HzMachine Specifications : Both the machines are flexibly coupled and mounted on a “C” Channel base, AC Machine (Act as prime mover), Type : Three Phase squirrel cage induction motor, Make: Havells / Siemens / L&T, Voltage Rating: 415VAC ± 10%, 50Hz, Speed : 1440 rpm ± 10%, Insulation: Class ‘F’, Winding: Copper, Duty: Continuous, Enclosure: TEFC, Mounting : Horizontal foot mounted, Shaft Extension: Single Sided, Loading arrangement : Electrical, DC Machine (Act as generator): Type : Series, Make: Alfa / Elmo, Rating : 1 HP, Generated Voltage Rating: 220VDC ± 10% at load, Speed : 1500 rpm ± 10%, Insulation : Class ‘F’, Winding : Copper, Duty: Continuous, Enclosure : SPDP, Terminals box: Powder coated/epoxy paint with terminals and fuses brought out at the top, Machine Base:MS “C” Channel with suitable interconnection, Digital meters (72x72mm) used: AC Voltmeter: 500V, AC Ammeter: 10A , DC Voltmeter: 300V, DC Ammeter: 20A , AC Starter: Type: DOL Starter (L&T / Siemens Make), Digital Tachometer, Range : 19,999 rpm , Type:Contact / Non-contact, Protection Devices: Glass Fuse : 3Nos, Grounding Nut : Available at the rear side of the panel, Scope of Learning:Study of DC Series Generator, Study of No Load Characteristics of Self Excited DC Series Generator, Study ofLoad Characteristics ofSelf Excited DC Series Generator, Supporting Accessories supplied with Control Setup, Patch Cords of different color scheme, Single Phase Mains Cord, Extra Glass Fuses,Digital Tachometer,Learning Material Manual , Optional Accessories (User need to quote these separately),Resistive Load , Nature of Load: Resistive, Loading Topology: Through toggle switches/MCB’s, Type of Load : Discrete , Single Phase Operation: Voltage: 240V AC/DC ± 10%, 50Hz, Current : 12A , Loading steps : 12 in step of 1A, Three Phase Star Operation : Voltage : 415V AC ± 10%, 50Hz, Current : 4A (each phase), Loading steps : 4 per phase in step of 1A, Three Phase Delta Operation : Voltage : 415V AC ± 10%, 50Hz, Current : 12A (each line), Loading steps : 4 per phase in step of 2.5A (Approx.), Star/Delta Switch: 415V, 25A, Mains MCB :32A (TPN) (Havells/ Siemens /anchor), Mains Indicators:3Nos (for each phase)
442Three Phase Induction Motor DC Compound Generator Training System
443Features: Machine with standard electrical loading arrangement through flexible love-joy coupler, Machine winding consist of copper for long term service, Machine Conforms to all leading industrial standards with Class “B/F” Insulation , Control panel not less than 680 x 320 x 480mm, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts, Provided with non contact/contact type Digital speed measuring equipment, Inbuilt DC Power Drive of suitable rating with overload protection, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts , Control panel with digital microcontroller based measuring devices with high accuracy and resolution, Front board consist of MS Material with power coating / epoxy paint to avoid any rust , Provided with suitable protection such as fuses, MCB, etc wherever requires, Specially designed BS10 Terminals and patch cords for electrical safety, Three Phase Supply indication lamps, Inbuilt AC DOL Starter which start and protect the machine from overload condition, Earthing screw provided at the back side of the control set-up, Screen printed diagrammatic representation for the ease of connections.,Productprovide with protection fuses, colored patch cords, single phase cords, learning manual contents having theory, operating procedure with connecting diagram, FAQ, Glossary, etc, Technical Specifications Operation Voltage of Control Panel : 415VAC ± 10%, 50Hz Auxiliary Supply of Control Panel : 230VAC ± 10%, 50HzMachine Specifications : Both the machines are flexibly coupled and mounted on a “C” Channel base, AC Machine (Act as prime mover), Type : Three Phase squirrel cage induction motor, Make: Havells / Siemens / L&T, Voltage Rating: 415VAC ± 10%, 50Hz, Speed : 1440 rpm ± 10%, Insulation: Class ‘F’, Winding: Copper, Duty: Continuous, Enclosure: TEFC, Mounting : Horizontal foot mounted, Shaft Extension: Single Sided, Loading arrangement : Electrical, DC Machine (Act as generator): Type : Compound, Make: Alfa / Elmo, Rating : 1 HP, Generated Voltage Rating: 220VDC ± 10% at load, Speed : 1500 rpm ± 10%, Insulation : Class ‘F’, Winding : Copper, Duty: Continuous, Enclosure : SPDP, Terminals box: Powder coated/epoxy paint with terminals and fuses brought out at the top, Machine Base:MS “C” Channel with suitable interconnection, Digital meters (72x72mm) used: AC Voltmeter: 500V, AC Ammeter: 10A , DC Voltmeter: 300V, DC Ammeter: 20A , AC Starter: Type: DOL Starter (L&T / Siemens Make), Digital Tachometer, Range : 19,999 rpm , Type:Contact / Non-contact, Protection Devices: Glass Fuse : 3Nos, Grounding Nut : Available at the rear side of the panel, Scope of Learning:Study of DC Compound Generator, Study Load Characteristics of Short Shunt DC Compound Generator, Study Load Characteristics of Long Shunt DC Compound Generator, Study Load Characteristics of Cumulative DC Compound Generator, Study Load Characteristics of Differential DC Compound Generator, Supporting Accessories supplied with Control Setup, Patch Cords of different color scheme, Single Phase Mains Cord, Extra Glass Fuses,Digital Tachometer,Learning Material Manual , Optional Accessories (User need to quote these separately),Resistive Load , Nature of Load: Resistive, Loading Topology: Through toggle switches/MCB’s, Type of Load : Discrete , Single Phase Operation: Voltage: 240V AC/DC ± 10%, 50Hz, Current : 12A , Loading steps : 12 in step of 1A, Three Phase Star Operation : Voltage : 415V AC ± 10%, 50Hz, Current : 4A (each phase), Loading steps : 4 per phase in step of 1A, Three Phase Delta Operation : Voltage : 415V AC ± 10%, 50Hz, Current : 12A (each line), Loading steps : 4 per phase in step of 2.5A (Approx.), Star/Delta Switch: 415V, 25A, Mains MCB :32A (TPN) (Havells/ Siemens /anchor), Mains Indicators:3Nos (for each phase)
444Hopkinson’s Test of DC Shunt Machine Training System
445Features: Machine with standard electrical loading arrangement through flexible love-joy coupler, Machine winding consist of copper for long term service, Machine Conforms to all leading industrial standards with Class “B/F” Insulation , Control panel not less than 680 x 320 x 480mm, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts, Provided with non contact/contact type Digital speed measuring equipment, Inbuilt DC Power Drive of suitable rating with overload protection, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts , Control panel with digital microcontroller based measuring devices with high accuracy and resolution, Front board consist of MS Material with power coating / epoxy paint to avoid any rust , Provided with suitable protection such as fuses, MCB, etc wherever requires, Specially designed BS10 Terminals and patch cords for electrical safety, Lamp indication for single phase supply, Screen printed diagrammatic representation for the ease of connections.,Productprovide with protection fuses, colored patch cords, single phase cords, learning manual contents having theory, operating procedure with connecting diagram, FAQ, Glossary, etc, Technical Specifications: Operating Supply of Control Panel: 230VAC ± 10%, 50Hz, Machine Specifications : Both the machines are flexibly coupled and mounted on a “C” Channel base, Type : Shunt, Make : Alfa / Elmo, Rating : 1 HP , Voltage Rating : 220VDC ± 10% , Speed : 1500 rpm ± 10% at load, Insulation: Class ‘F’, Winding : Copper, Duty : Continuous, Enclosure : SPDP, Mounting : Horizontal foot mounted, Shaft Extension : Single Sided, Loading arrangement : Electrical, Digital meter (72x72mm)s used, DC Voltmeter: 300V , DC Ammeter: 20A (4nos) , DC Power Supply (with field failure, overload protection, must be operated at pmdc and shunt mode), Mains Supply : 220VAC ± 10%, 50Hz, Output Variable voltage : 0 - 240VDC ± 10% , Current Rating : 15A, Digital Tachometer: Range : 19,999 rpm , Type:Contact / Non-contact, Protection Devices: MCB (DP): 1No (Havells/ Siemens /anchor), Glass Fuse : 3Nos, Grounding Nut : Available at the rear side of the panel, Scope of Learning: Study and obtain the losses separately and correspondingly., Determine the efficiency of a DC Shunt Machine by Hopkinson"s test, Supporting Accessories supplied with Control Setup, Patch Cords of different color scheme, Single Phase Mains Cord, Extra Glass Fuses, Digital Tachometer, Learning Material Manual , Optional Accessories (User need to quote these separately), Rheostat, 2.8A, 400Ohms (2Nos.)
446Field Test of DC Shunt Machine Training System
447Features: Machine with standard electrical loading arrangement through flexible love-joy coupler, Machine winding consist of copper for long term service, Machine Conforms to all leading industrial standards with Class “B/F” Insulation , Control panel not less than 680 x 320 x 480mm, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts, Provided with non contact/contact type Digital speed measuring equipment, Inbuilt DC Power Drive of suitable rating with overload protection, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts , Control panel with digital microcontroller based measuring devices with high accuracy and resolution, Front board consist of MS Material with power coating / epoxy paint to avoid any rust , Provided with suitable protection such as fuses, MCB, etc wherever requires, Specially designed BS10 Terminals and patch cords for electrical safety, Lamp indication for single phase supply, Screen printed diagrammatic representation for the ease of connections.,Productprovide with protection fuses, colored patch cords, single phase cords, learning manual contents having theory, operating procedure with connecting diagram, FAQ, Glossary, etc, Technical Specifications: Operating Supply of Control Panel: 230VAC ± 10%, 50Hz, Machine Specifications : Both the machines are flexibly coupled and mounted on a “C” Channel base, DC Machine (Act as prime mover):Type : Series, Make : Alfa / Elmo, Rating : 1 HP , Voltage Rating : 220VDC ± 10% , Speed : 1500 rpm ± 10% at load, Insulation: Class ‘F’, Winding : Copper, Duty : Continuous, Enclosure : SPDP, Mounting : Horizontal foot mounted, Shaft Extension : Single Sided, Loading arrangement : Electrical, DC Machine (Act as generator) Type: Series,Make: Alfa / Elmo, Rating : 1 HP , Generated Voltage Rating: 220VDC± 10% at load, Speed: 1500 rpm ± 10%, Insulation : Class ‘F’, Winding: Copper, Duty : Continuous, Enclosure : SPDP, Terminals box : Powder coated with terminals and fuses brought out at the top, Machine Base :MS “C” Channel with suitable interconnection, Digital meter (72x72mm)s used, DC Voltmeter: 300V , DC Ammeter: 20A (4nos) , DC Power Supply (with field failure, overload protection, must be operated at pmdc and shunt mode), Mains Supply : 220VAC ± 10%, 50Hz, Output Variable voltage : 0 - 240VDC ± 10% , Current Rating : 15A, Digital Tachometer: Range : 19,999 rpm , Type:Contact / Non-contact, Protection Devices: MCB (DP): 1No (Havells/ Siemens /anchor), Glass Fuse : 3Nos, Grounding Nut : Available at the rear side of the panel, Scope of Learning: • Study of No Load Characteristics DC Series Generator,Study of (Internal and External) Load Characteristics of DC Series Generator, Supporting Accessories supplied with Control Setup, Patch Cords of different color scheme, Single Phase Mains Cord, Extra Glass Fuses,Digital Tachometer,Learning Material Manual , Optional Accessories (User need to quote these separately),Resistive Load , Nature of Load: Resistive, Loading Topology: Through toggle switches/MCB’s, Type of Load : Discrete , Single Phase Operation: Voltage: 240V AC/DC ± 10%, 50Hz, Current : 12A , Loading steps : 12 in step of 1A, Three Phase Star Operation : Voltage : 415V AC ± 10%, 50Hz, Current : 4A (each phase), Loading steps : 4 per phase in step of 1A, Three Phase Delta Operation : Voltage : 415V AC ± 10%, 50Hz, Current : 12A (each line), Loading steps : 4 per phase in step of 2.5A (Approx.), Star/Delta Switch: 415V, 25A, Mains MCB :32A (TPN) (Havells/ Siemens /anchor), Mains Indicators:3 Nos (for each phase).
448DC Starter Training System
449Features: Machine with standard electrical loading arrangement through flexible love-joy coupler, Machine winding consist of copper for long term service, Machine Conforms to all leading industrial standards with Class “B/F” Insulation , Control panel not less than 680 x 320 x 480mm, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts, Provided with non contact/contact type Digital speed measuring equipment, Inbuilt DC Power Drive of suitable rating with overload protection, Heavy Duty Base/Channel with facility to concrete machine using suitable heavy nuts and bolts , Control panel with digital microcontroller based measuring devices with high accuracy and resolution, Front board consist of MS Material with power coating / epoxy paint to avoid any rust , Provided with suitable protection such as fuses, MCB, etc wherever requires, Specially designed BS10 Terminals and patch cords for electrical safety, Lamp indication for single phase supply, Screen printed diagrammatic representation for the ease of connections.,Productprovide with protection fuses, colored patch cords, single phase cords, learning manual contents having theory, operating procedure with connecting diagram, FAQ, Glossary, etc, Note: (Overload protection will be possible with Motor rating upto or above 3HP) Technical Specifications: Operating Supply of Control Panel: 230VAC ± 10%, 50Hz, DC Two Point Starter: 1Nos. , DC Three Point Starter : 1Nos. , C Four Point Starter : 1Nos., Controller Based Digital meter (72x72mm)s used (72 x 72mm), DC Voltmeter : 300V , DC Ammeter: 20A , DC Power Source (with field failure, overload protection, must be operated at pmdc and shunt mode), Output voltage : 220VDC ± 10% , Current Rating: 12A, DC Machine (Shunt Motor, Series Motor and Compound Motor to be offered separately), Power Rating : 3HP, Make :Alfa / Elmo, Voltage Rating: 220VDC± 10%, Field Excitation : 200VDC ± 10%, Speed : 1500 rpm ± 10%, Insulation: Class ‘F’, Winding: Copper, Duty: Continuous, Enclosure : SPDP, Mounting : Horizontal foot mounted, Loading arrangement : Mechanical , Brake Drum/Pulley : MS/Aluminum Casted with heat suppression facility inside it, Spring Balance: 2Nos. (Salter make), Loading Nut & Bolts : Brass material, Terminals box: Powder coated/epoxy paint with terminals and fuses brought out at the top, Machine Base:MS “C” Channel with suitable interconnection, Digital Tachometer : Range : 19,999 rpm (lutron make), Type :Contact / Non-contact, Protection Devices, MCB (DP) : 1No (Havells / Siemens/ Anchor , Glass Fuse: 3Nos, Grounding Nut : Available at the rear side of the panel, Scope of Learning:Study of DC Two Point Starter and its connection using DC Series Motor,Study of DC Three Point Starter and its connection using DC Shunt Motor,Study of DC Four Point Starter and its connection using DC Compound Motor, Supporting Accessories supplied with Control Setup, Patch Cords of different color scheme, Single Phase Mains Cord,Extra Glass Fuses,DigitalTachometer, Learning Material Manual
450Single Phase Transformer Training
451Features:Control panel with digital microcontroller based measuring devices with high accuracy and resolution, Transformer winding consist of copper for long term service,Inbuilt Single phase auto-transformer to get multiple readings,Inbuilt Single Phase resistive load that to be controlled by separate switches with indicator, Front board consist of MS Material with power coating / epoxy paint to avoid any rust , Provided with suitable protection such as fuses, MCB, etc wherever requires, Separate auxiliary supply facility to enable digital measuring instruments, Specially designed BS10 Terminals and patch cords for electrical safety, Lamp indication for single phase supply, Screen printed diagrammatic representation for the ease of connections.,Productprovide with protection fuses, colored patch cords, single phase cords, learning manual contents having theory, operating procedure with connecting diagram, FAQ, Glossary, etc, Technical Specifications: Mains Supply: Single Phase, 230VAC ±10%, 50Hz, Single Phase Transformer : Rating : 1000VA , Primary Voltage: 0-125V-0-125V, Secondary Voltage: 0-125V-0-125V, Rated Current: 4A, Winding : Copper , Efficiency : Above 85% (considering experimental losses), Type: E-I Core, Single Phase Auto-Transformer , Rating : 1000VA , Primary Voltage: 230VAC ±10%, 50Hz, Secondary Voltage: 0-270VAC ±10%, 50Hz, Rated Current: 4A, Winding : Copper, Type: Toroidal Core, Digital Meters Used, Technology Used: Microcontroller based, AC Voltmeter : 500V (2nos.), AC Ammeter: 10A (2nos.), Wattmeter: 1.5kW, Single Phase Resistive Load: Rating : 1kW, Type: Resistive Tubes, Steps : 1A with indicator, Control Scheme: Through Toggle Switch, Protection Devices: MCB (DP): 6A, Glass Fuse : 5A, Grounding Nut: Available at the rear side of the panel, Scope of Learning, Study of Isolation Transformer, Study of Step-up Transformer, Study of Step-down Transformer, Study of Additive Polarity Test in a Single Phase Transformer, Study of Subtractive Polarity Test in a Single Phase Transformer, Study of Open Circuit Test in a Single Phase Transformer, Study and calculate power factor and equivalent parameters under Open Circuit Test, Study of Short Circuit Test in a Single Phase Transformer, Study and calculate power factor and equivalent parameters under Short Circuit Test, Study of Load Test and correspondingly determine the Efficiency of Single Phase Transformer under different , Loading conditions, Study of Voltage Regulation in a Single Phase Transformer, Supporting Accessories supplied with Control Setup, Patch Cords of different color scheme, Single Phase Mains Cord, Extra Glass Fuses, Learning Material Manual (softcopy)
452Parallel Operation of Two Single Phase Transformer Training System
453Features:Control panel with digital microcontroller based measuring devices with high accuracy and resolution, Transformer winding consist of copper for long term service,Inbuilt Single phase auto-transformer to get multiple readings,Inbuilt Single Phase resistive load that to be controlled by separate switches with indicator, Front board consist of MS Material with power coating / epoxy paint to avoid any rust , Provided with suitable protection such as fuses, MCB, etc wherever requires, Separate auxiliary supply facility to enable digital measuring instruments, Specially designed BS10 Terminals and patch cords for electrical safety, Lamp indication for single phase supply, Screen printed diagrammatic representation for the ease of connections., Productprovide with protection fuses, colored patch cords, single phase cords, learning manual contents having theory, operating procedure with connecting diagram, FAQ, Glossary, etc, Technical Specifications: Mains Supply: Single Phase, 230VAC ±10%, 50Hz, Single Phase Transformer (2Nos), Rating : 1kVA , Primary Voltage: 0-230V±10%, 50Hz, Secondary Voltage: 0-210V – 220V – 230V ±10%, 50Hz, Rated Current : 4A, Winding : Copper, Type: E-I Core, Digital Meters Used: Technology Used: Microcontroller based, AC Voltmeter: 500V (2nos.), AC Ammeter: 10A (2nos.), Single Phase Resistive Load, Rating : 1kW, Type: Resistive Tubes, Steps: 1A with indicators , Control Scheme: Through Toggle Switch, Protection Devices: MCB (DP): 6A, Glass Fuse : 5A, Grounding Nut : Available at the rear side of the panel, Scope of Learning: Study of Additive Polarity Test in a Single Phase Transformer, Study of Subtractive Polarity Test in a Single Phase Transformer, Study of parallel operation of two single phase transformers with equal voltage ratio, Study of parallel operation of two single phase transformers with unequal voltage ratio, Supporting Accessories supplied with Control Setup, Patch Cords of different color scheme, Single Phase Mains Cord, Extra Glass Fuses, Learning Material Manual (softcopy), 10A, Single Phase Closed Type Autotransformer
454Sumpner’s Test of Two Single Phase Transformer Training System
455Features:Control panel with digital microcontroller based measuring devices with high accuracy and resolution, Transformer winding consist of copper for long term service,Inbuilt Single phase auto-transformer to get multiple readings, Equipped with temperature measuring device to analysis transformer’s heat, Front board consist of MS Material with power coating / epoxy paint to avoid any rust , Provided with suitable protection such as fuses, MCB, etc wherever requires, Separate auxiliary supply facility to enable digital measuring instruments, Specially designed BS10 Terminals and patch cords for electrical safety, Lamp indication for single phase supply, Screen printed diagrammatic representation for the ease of connections.,Productprovide with protection fuses, colored patch cords, single phase cords, learning manual contents having theory, operating procedure with connecting diagram, FAQ, Glossary, etc, Technical Specifications, Mains Supply: Single Phase, 230VAC ±10%, 50Hz, Single Phase Transformer (2Nos): Rating : 1kVA , Primary Voltage : 0-125V – 0V – 125V ±10%, 50Hz, Secondary Voltage : 0-125V – 0V – 125V ±10%, 50Hz, Rated Current : 4A, Winding : Copper, Efficiency :Above 85% (considering experimental losses), Type: E-I Core, Digital Meters Used: Technology Used: Microcontroller based, AC Voltmeter: 500V (2nos.), AC Ammeter: 10A (2nos.), Wattmeter: 1.5kW (2Nos.), Single Phase Autotransformer: Primary Voltage: 230V AC ±10%, 50Hz, Secondary Voltage: 0 - 270V AC ±10%, Rating : 10A, Type: Open Type, Protection Devices: MCB (DP): 10A, Glass Fuse : 10A, Grounding Nut : Available at the rear side of the panel, Scope of Learning: Study of Additive Polarity Test in a Single Phase Transformer, Study of Subtractive Polarity Test in a Single Phase Transformer,Study of Open Circuit Test and Short Circuit Test taking two single phase transformer and consequently calculate efficiency and voltage regulation of transformer with different loading configurations, Supporting Accessories supplied with Control Setup, Patch Cords of different color scheme, Single Phase Mains Cord, Extra Glass Fuses, Learning Material Manual (softcopy)
456Three Phase Scott Connection Training System
457Features: Control panel with digital microcontroller based measuring devices with high accuracy and resolution, Transformer winding consist of copper for long term service. Front board consists of MS Material with power coating to avoid any rust., Separate auxiliary supply facility to enable digital measuring instruments, Equipped with 2Nos. bulb holder to test conversion, Lamp indicators for three phase mains, Equipped 2Nos. low voltage transformer to check waveform over CRO, Control Panel with round grills fitted on both sides for cooling purpose., Provided with suitable protection such as fuses, MCB, etc wherever requires, Specially designed BS10 Terminals and patch cords for electrical safety, Lamp indication for single phase supply, Screen printed diagrammatic representation for the ease of connections., , Productprovide with protection fuses, colored patch cords, single phase cords, learning manual contents having theory, operating procedure with connecting diagram, FAQ, Glossary, etc, Technical Specifications, Mains Supply : Three Phase, 415VAC ±10%, 50Hz, Main Transformer (Center tapped), Power Rating: 1000VA, Current Rating : 4A, Primary Winding: 200-0-200V ±10%, 50Hz, Secondary Winding: 0-230V ±10%, 50Hz, Winding: Copper, Type : E-I Core, Teaser Transformer: Power Rating: 1000VA, Current Rating : 4A, Primary Winding: 0-115.6V (28.9%) ±10%, 50Hz, 346.4V (86.6%) ±10%, 50Hz, 400V ±10%, 50Hz, Secondary Winding: 0-230V ±10%, 50Hz, Winding: Copper, Type : E-I Core, Step down Transformers (2 Nos.), Primary Winding: 0-230V ±10%, 50Hz , Secondary Winding: 0-18V ±10%, 50Hz, Winding: Copper , Digital Meters Used, Technology: Microcontroller based, AC Voltmeter: 500V (2nos.), AC Ammeter : 10A (2nos.), Protection Devices: MCB (TPN) : 6A, Glass Fuse: 5A, Grounding Nut: Available at the rear side of the panel, Scope of Learning, Study of Main Transformer, Study of Teaser Transformer , Study of Scott Connection (Three Phase to Two Phase Conversion), Supporting Accessories supplied with Control Setup, Patch Cords of different color scheme, Single Phase Mains Cord, Three Phase Socket, Extra Glass Fuses, Learning MaterialManual (softcopy), 6A, Three Phase Closed Type Autotransformer , CRO
458Three Phase Transformer Training System
459Features: Control panel with digital microcontroller based measuring devices with high accuracy and resolution, Transformer winding consist of copper for long term service. Front board consists of MS Material with power coating to avoid any rust., Separate auxiliary supply facility to enable digital measuring instruments,Facility to configure either step up, step down or isolation transformer, Lamp indicators for three phase mains , Control Panel with round grills fitted on both sides for cooling purpose., Provided with suitable protection such as fuses, MCB, etc wherever requires, Specially designed BS10 Terminals and patch cords for electrical safety, Lamp indication for single phase supply, Screen printed diagrammatic representation for the ease of connections.,Productprovide with protection fuses, colored patch cords, single phase cords, learning manual contents having theory, operating procedure with connecting diagram, FAQ, lossary, etc, Technical Specifications, Mains Supply : Three Phase, 415VAC ±10%, 50Hz, Three Phase Transformer: Rating: 1000VA , Primary Voltage : 415V AC ±10%, 50Hz, Secondary Voltage : 230V AC ±10%, 50Hz, Rated Current : 4A, Winding : Copper, Type: E-I Core, Digital Multimeter Meters Used , Technology Used: Microcontroller based, AC Voltmeter : 500V , AC Ammeter: 10A , Wattmeter : 1.5kW (2Nos.), Protection Devices: MCB (TPN): 10A, Glass Fuse : 5A, Grounding Nut : Available at the rear side of the panel, Scope of Learning: Study of Open Circuit Test in a Three Phase Transformer, Study of Short Circuit Test in a Three PhaseTransformer, Study of Load Test and correspondingly determine the Efficiency and Voltage Regulation in a Three Phase Transformer, Supporting Accessories supplied with Product, Patch Cords of different color scheme, Single Phase and Three Phase Mains Cord,Extra Glass Fuses, Learning Material Manual (softcopy), 8A Three Phase Closed Type Autotransformer , Three Phase Resistive Load.
460POWER ELECTRICAL LAB Experiment to study characteristics of DIAC, SCR and TRIAC
461Generalized design, In- built Power supply of +15, +35V and -35V, DPM Based highly preceised on-board Voltmeter & Ammeter, Breadboard Provided with different values of resistances,10 turn potentiometer, To study and plot the V-I Characteristics of DIAC with Positive and Negative biasing Study and observation of Break over voltage (VBO) and VBO Symmetry of DIAC, To study and plot the V-I Characteristic of TRIAC with Positive and Negative biasing Study of Gate Current Triggering of TRIAC, To study the phenomena of Holding Current and Latching current in TRIAC, To Study and plot V-I Characteristic of SCR, Study of Gate Current Triggering of SCR, To study the phenomenon of holding current and latching current in SCR,Mains power supply : 90 - 270V ±10%, 50Hz Fixed DC power supply : +15V, Regulated, +35V Regulated, -35V Regulated,Bread Board: Dimension (mm) : 75 x 61 x 10, Distribution strips : 2, Terminal strips : 1,Distribution holes : 200,Terminal holes : 640, DIAC : DB3, TRIAC : BT136, SCR : TYN616, Resistor Bank: M.F.R. 2.2K 1% 1/4W (3 Nos.),M.F.R. 470E 1% 1/4W (3 Nos.),M.F.R. 1K 1% 5W (3 Nos.),M.F.R. 4.7K 1% 5W (3 Nos.),M.F.R. 1K 1% 10W (3 Nos.),Variable Resistance bank:5K 10 turn Potentiometer (2 Nos.),Voltmeter Range : 0V to 99V,Ammeter Range : 0mA to 20mA
462Experiment to study characteristics of transistor and MOSFET
463Generalized design, Standalone operation, Inbuilt fixed and variable power supply, Toggle switch for selection of variable power supply, Inbuilt Ammeter and Voltmeter, Bread board, Resistance bank,10 turn potentiometer, To study and plot the Drain Characteristics of n channel MOSFET, To study and plot the Transfer Characteristics of n channel MOSFET, To study and plot the V-I characteristics of JFET, Evaluation of following parameters of JFET:DC Drain resistance,Transconductance,Amplification factor, To plot the VI characteristics of UJT, Evaluation of following parameters of UJT:Intrinsic Stand- off Ratio,Inter base resistance,Mains Supply : 90-230V, 50Hz DC Fixed Power Supply : -5V, +15V, +35V,DC Variable Power Supply :1.5V to 14 V,1.5V to 34V,Voltmeter : 0-200V,Ammeter : 0-200mA,Bread Board,Dimension (mm) : 175 x 61 x 10,Distribution strips : 2,Distribution holes : 200,Terminal Strips : 1,Terminal holes : 640,Resistor Bank : M.F.R. 100E 1W (3 Nos.),M.F.R. 470E 1W (3 Nos.),M.F.R. 1K 1W(3 Nos.),Variable Resistances : 5 K? Ten turn Potentiometer (1 No.),10 K? Ten turn Potentiometer (1 No.),5 K? Single turn Potentiometer (1 No.),Fuse : 500 mA, slow blow
464Experiment to study R and RC firing circuit
465Built in Power Supply, Easy to operate and understand, Three firing circuits on single board, Gradual firing angle control, Test points for observe output of different circuits, Sockets to make different connections,On board AC source of 0V-18 V, Study of the: Resistor Triggering Circuit, RC Full & Half Wave Triggering Circuit, On board AC source : 0 V - 18 V,On board firing circuits:R Triggering Circuit,RC Half Wave Triggering Circuit,RC Full Wave Triggering Circuit, Interconnections : 2 mm sockets, Firing angle variation : Gradually variation using firing control (2MW), SCR : 1 SCRs 2P4M, 400 V/2A, Test points : 8 nos
466Experiment to study UJT firing circuit
467Built in power supply,Easy to operate and understand.,Two triggering circuits on single board.,Test points for observe output pulses.,Sockets to make different connections.,On board DC sources of 5 V and 12 V., Study of the triggering of SCR using UJT,Study of the triggering of SCR using TC555, On board AC source : 18 V - 0 V - 18 V,On board DC Supply : +5 V, +12 V,On board triggering circuits :,555 IC triggering circuit,UJT triggering circuit,Interconnection : 2 mm socket,SCR : SCRs TYN616, 600V/16 A,Test points : 4 nos, Power Supply : 110V - 260V AC, 50/60Hz, Operating Conditions : 0-40 C, 85% RH
468To study three phase full wave uncontrolled rectifier operation with R and RL load and to observe its input output waveform
469On Board ( Mains) AC Power Supplies- Single Phase Power Supply,Three Phase Power Supply,On Board Step down AC Power Supplies- Single Phase Power Supply, Three Phase Power Supply,MCB Protected Single and Three Phase AC Supply, Three Phase indicator (R-Y-B) at frontpanel, On Board Oscilloscope with Power Scope, On Board DC/AC Voltmeter and DC/AC Ameter, On Board Firing Circuits: Single Phase Firing Circuit, Three Phase Firing Circuit, Cycloconverter Firing Circuit, Test point are provided to observe waveforms at different blocks in Firing Circuit, On Board Power Devices AssemblyDiode Assembly, SCR Assembly, IGBT Assembly, Internal RC snubber circuit in Power Circuit Module, 2 mm and 4 mm Socket provided to make different connections, Easily replaceable Firing Circuit and Power Circuit Module, Four 200 W Bulb as Lamp Load, Universal Motor 1/8 HP as Motor Load, Short Circuit Protection, Easy to operate and understand,Exhaust fan at back panel for cooling, Study of Single Phase Uncontrolled Rectifier ( Diode Rectifier): Half-Wave Rectifier on R Load, RL Load and Freewheeling Diode, Full-Wave Mid-point Rectifier on R Load, RL Load and Freewheeling Diode, Full-Wave Bridge Rectifier on R Load, RL Load and Freewheeling Diode, Study of Single Phase Controlled Rectifier: Ramp and Comparator Firing Circuit, Half-Wave Rectifier on R Load, RL Load and Freewheeling Diode, Full-Wave Mid-point Rectifier on R Load, RL Load and Freewheeling Diode, Full-Wave Bridge Rectifier on R Load, RL Load and Freewheeling Diode, Full Converter, Semiconverter, Symmetrical Semiconverter (Common Cathode & Common Anode type) wAsymmetrical Semiconverter (Half Controlled & Full Controlled type)Study of Single Phase AC Voltage Controller: Study of Cycloconverter Firing Circuit, AC voltage on off control on R Load, RL Load and Freewheeling Diode, Half Wave AC voltage controller on R Load, RL Load and Freewheeling Diode, Full Wave AC voltage controller on R Load, RL Load and Freewheeling Diode, Cycloconverter on R Load, RL Load and Freewheeling Diode, Study of Three Phase Uncontrolled Rectifier (Diode Rectifier): Half-Wave Rectifier on R Load, RL Load and Freewheeling Diode, Common Cathode Configuration, Common Anode Configuration, Full-Wave Bridge Rectifier on R Load, RL Load and Freewheeling Diode, Study of Three Phase Controlled Rectifier : Three Phase Firing Circuit, Half Wave Controlled Rectifier common cathode configuration on R Load, RL Load and Freewheeling Diode, Semiconverter on R Load, RL Load and Freewheeling Diode, Half Wave AC Voltage Controller on R Load, RL Load and Freewheeling Diode, Full Wave AC Voltage Controller on R Load, RL Load and Freewheeling Diode, MCB (Power Switch) : Single Phase 10A, MCB (Power Switch) : Three Phase 10A, Single Phase AC Power Supply : 230V, ± 10%, 50Hz, 115V - 0 - 115V ± 10%, 2A, Single Phase Low Voltage AC Power Supply: 18V - 0 - 18V, 15V-0, Low Voltage DC Power Supply : +30V, -30V 250mA, +15V, -15V 250mA, +12V, -12V 500mA, +5V, -5V 500mA, Three Phase AC Power Supply : 230V Phase voltage ± 10% 50Hz, 440 Line voltage ± 10% 50Hz, Three Phase Low Voltage : 15V Each Phase ± 10%, 50Hz, Power Supply, Interconnections : 2mm & 4mm Safety Socket, Diode Assembly : Diode 6A10 1000V/6A, SCR Assembly : TYN 616 600V/16A, IGBT Assembly : IGBT G4BC20S 600V/10A Gate Firing Circuits, Single Phase Firing Circuit : Ramp Comparator Firing Circuit (Firing Angle Control 30-180 ), Three Phase Firing Circuit : Three Phase Firing Circuit (Firing Angle Control 30-150 ), Cycloconverter Firing Circuit : Cycloconverter Firing Circuit (Firing Angle Control 30-180 ), Single Phase and Three Phase Inverter firing circuit: Firing Pulse - 50Hz Square Wave with 10Vpp, Measuring Instruments, Digital Storage Oscilloscope: Bandwidth : 50MHz, Realtime Sample Rate : 500MSa/s (Single Channel), Equivalent Sample Rate : 50GSa/s, Number of Channels : 2 CH +1 Ext, Memory Depth : 32 Kpts (Single Channel), Acquisition Modes : Normal/Average/Peak Detect, Average : Selectable from 4 to 256, Vertical Sensitivity : 2mV/div - 10V/div, Vertical Resolution : 8bits, Input Impedance : 1 M? ±2% II 17 pF ±3 pF, Input Coupling : DC, AC and GND, Maximum Input Voltage : ±400Vpp, Power Scope: : 1500V Isolated measurement, Digital AC Voltmeter : 0-500V AC Voltage Measurement, Digital AC Ammeter : 0-25A AC Current Measurement, Digital DC Voltmeter : 0-650V DC Voltage Measurement, Digital DC Ammeter : 0-25A DC Current Measurement, Load Assembly : R Load- Lamp Load (200W)-4nos., L Load -Inductive Load 300-350-400mH, 1.5A
470Experiment to study DC chopper
471Built in DC Power Supply, On board firing circuit, Test points provided to check the outputs at different blocks, Easy to operate and understand, Sockets provided to make different connections, Study SCR Firing Circuit., Study Step-Up Chopper with resistive load., Study Step-Up Chopper with resistive inductive load., On board firing circuit : Triangular wave compartor firing scheme, Frequency variation : 27 Hz to 5 KHz (approx.), PWM variation : 0 - 50%, Interconnections : 2 mm sockets, SCR assembly : SCR TYN 616, 600 V, 16A, Test points : 5 nos, Mains Supply : 220V/110V; 50 Hz / 60Hz,Included Accessories : 2mm Patch cords (Red) 16"-1 no., 2mm Patch cords (Black) 16"-1 no., 2mm Patch cords (Blue) 16"-8 nos., Mains cord-1 no.
472Experiment to study single phase cyclo converter characteristics
473Built in Power Supply, Easy to operate and understand, On board firing circuits, Gradual firing angle control upto 180°, Test points to observe output of different blocks, Sockets for making interconnections, Study firing circuit of single-phase cycloconverter., Study single phase mid - point cycloconverter with resistive and inductive load., On board firing circuits : Ramp comparator firing scheme, Interconnections : 2mm sockets, Firing angle variation : Gradual variation from 0 to 180 degree, SCR assembly : 4 SCRs 2P4M, 400V/2A, Pulse transformer : PT4503 , 1:1:1, Mains Supply : 220V/110V, 50 Hz / 60 Hz, Load : Resistance-279E, 5W, Test points : 9 nos
474To study single phase full wave controlled rectifier using SCR with R and RL load and observe its input / output waveform with and without free willing (commutating) diode
475Self contained & easy to operate, Functional blocks indicated on board mimic, Breadboard provided for own circuit development, In built DC Power Supplies, In built AC Power Supplies, Onboard pulse generator with frequency and duty cycle control., On board single phase controlled rectifier firing circuit, On board thyristor devices, On board pulse amplifier and isolation transformer, On board variable load and circuit components, VI characteristics of power devices, Study of Single Phase Thyristor Firing Scheme, Single Phase Controlled Rectifiers, DC to DC Chopper, Single Phase Inverter, Own circuit Development, Optional circuit components for breadboard related experiments, Size of Breadboard : 172.5 mm × 128.5 mm, DC Power Supply : +5 V, -5 V 500 mA, +12V, -12 V 500 mA, +15 V, 250 mA, +35V, -35V, 250 mA, AC Power Supply : 18V-0V-18V, 0V-15V, On board Firing Circuits, Frequency range : 30Hz to 900Hz variable, Amplitude : 12V, PWM control of G1, G2, G3 and G4, Duty cycle control of “Gate” Signal is 0 to 100%, SCR Assembly : 4 SCRs 2P4M, 400V/2A, Power Devices : IGBT-G4BC20S, MOSFETIRFZ44N, UJT-2N2646, DIACDB3, TRIAC-BT136, PUT2N6027, Pulse transformer on board : 2 nos. PT4502 1:1 and one is PT4503 1:1:1, Circuit Components on board: Electrolytic Capacitor 1uF, 63V, Metalized Capacitor 0.1uF, 63V, Metalized Capacitor 0.33uF, 63V, Diode 1N4007, Inductor 68mH, Inductor 68mH, Inductor 10mH, Load selector : 6 load resistances- 47E/7W, 120E/5W, 270E/5W, 2K2/2W,1K/1W, 1K/10W, Test points : 10 nos, Power Supply (Mains) : 220V/110V, 50Hz/60Hz, Included Accessories : Bread boards : 2 nos., Connecting wires : 20 nos., 2mm to 1mm Patch cords : 15 nos., 2mm Patch cords (Red) 16” : 4 nos., 2mm Patch cords (Black)16’’ : 4 nos., 2mm Patch cords (Blue) 16’’ : 12 nos., Mains cord : 1 no.
476Experiment to study lamp dimmer circuit using DIAC and TRIAC with lamp load
477Built in Power Supply, Easy to operate and understand, On board two firing circuits, Gradual firing angle control up to 180 degree,In-built Power Isolation Circuit, Switch for selection of firing circuit, Study lamp dimmer using DIAC & TRIAC firing scheme, Study lamp dimmer using UJT firing scheme, On board firing circuits :DIAC TRIAC firing circuit, UJT firing circuit, SCR & TRIAC : 1 SCRs TYN 616, 600V/16A and TRIAC BT136, Load : Lamp 100W, Mains Supply (mains) : 220V/110V, 50 Hz/60 Hz
478DIGITAL ELECTRONICS LAB Verify truth table of AND, OR, NOT, NAND, NOR and XOR gates
479Exclusive and compact design, Straight forward representation of all logic gates, +5V SMPS Adaptor provided with the trainer for power supply, Designed by considering all the safety standards, Online product tutorial, product including illustration of all logic gates, Study of AND gate and to verify its truth table, Study of OR gate and to verify its truth table, Study of NOT gate and to verify its truth table, Study of NAND gate and to verify its truth table, Study of NOR gate and to verify its truth table, Study of XOR gate and to verify its truth table, Study of XNOR gate and to verify its truth table, Input : +5V DC Logic levels: +5V : HIGH ( Logic 1 ), 0V : LOW ( Logic 0 )
480Implement (i) half adder (i) full adder using AND - OR gates.
481Exclusive and compact design, Adaptable illustration of Binary Adders and Subtractors, +5V SMPS Adaptor provided with the trainer for power supply, Designed by considering all the safety standards, Study of Binary Half Adder, Study of Binary Full Adder using two Half Adders, Study of Binary Half Subtractor, Input : +5V DC, Logic levels: +5V : HIGH ( Logic 1 ), 0V : LOW ( Logic 0 )
482Verify truth tables of RS and JK flip flops and convert JK flip flops into D type and T type flip flop
483Exclusive and compact design, Adaptable illustration of Flip-Flops, +5V SMPS Adaptor provided with the trainer for power supply, Designed, considering all the safety standards, Study of S-R Flip-Flop and to verify its Transition table, Study of J-K Flip-Flop and to verify its Transition table, Study of D Flip-Flop and to verify its Transition table, Study of T Flip-Flop and to verify its Transition table, Input : +5V DC, Logic levels: +5V : HIGH(Logic 1), 0V : LOW (Logic 0)
484Use 555 timer as (i) monostable (ii) astable multivibrator
485In-built +5V regulated DC Power Supply, In-built 1KHz pulse generator for triggering the monostable circuit, Good quality, reliable sockets and test points are provided, Strongly supported by systematic operating instructions, To study the IC 555 as a Monostable (One-Shot) Multivibrator,To study the IC 555 as an Astable (Free-Running) Multivibrator, Mains Supply : 230V ±10%, 50Hz, DC Bias Voltage : +5V, Frequency of Trigger : 1KHz, Pulse Generator, Frequency Range of Astable Multivibrator: 600Hz – 3.2KHz (approximate), Frequency Range of Bistable Multivibrator : 350Hz – 1KHz (approximate),Output Voltage : 5V (approximate)
486(a) Use of 4 bit shift register for shift left and shift right operation (b) use 4 bit shift register as a ring counter
487Stand alone system, Easy illustration of all types of 3-bit and 4-bit shift registers, LEDs for visual indication of input and output logic states, SPDT switches for easy input logic selection, Study of 3-bit and 4-bit serial in serial out shift register (using D Flip-Flops), Study of 3-bit and 4-bit serial in parallel out shift register (using D Flip-Flops), Study of 3-bit and 4-bit parallel in serial out shift register (using D Flip-Flops), Study of 3-bit and 4-bit parallel in parallel out shift register (using D Flip-Flops), DC Power Supply : +5V, Logic levels :+5 V : High (Logic 1), 0 V : Low (Logic 0), LED Indication : LED will be ON for logic high or "1" state and will be OFF for logic low or "0" state
488Implement mode - 10 counter and draw its output waveform
489Stand Alone system, Easy illustration of different types of counters, LEDs for visual indication of input and output logic states, SPDT switches for input logic selection, Study of 4 bit synchronous binary up Counter, Study of 4 bit asynchronous binary up/down Counter, Verification of operation of IC 74LS190 as a modulo-N programmable Counter, DC Power Supply : +5V DC, Logic levels: +5V : High (Logic 1), 0V : Low (Logic 0), LED Indication : LED will be ON for logic high or "1" state and will be OFF for logic low or "0" state
490ELECTRONICS LAB Familiarisation with Electronic Components (Active & Passive)
491Resistors (different Types),Capacitors (different Types),Inductors / Coil,Diodes,Rectifier Diode,Zener Diode,Varicap,Varactor,Light-Emitting Diode (LED),Transistors,Photo Transistor,Darlington Transistor,Compound Transistor,Field-Effect Transistor (FET), JFET (Junction Field-Effect Transistor),MOSFET (Metal Oxide Semiconductor FET),Thyristors
492Familiarisation With Electronic Equipments (Multimeter, CROs, Power Supply and Function generator)
493Multimeter Demonstrator Easy illustration of different blocks of Multimeter,Strongly supported by systematic operating instructions with theoretical and practical details,Designed with considering all safety standards, Study of DC and AC Voltage Measurement, Study of DC and AC Current Measurement, Study of Resistance Measurement, Study of Continuity Tester, Voltage:-DC Voltage : 0 - 350V,AC RMS Voltage : 0 - 350V, Current:-DC Current : 0 - 2A,AC Current : 0 - 2A,Resistance : 0 - 2MV,On Board Fuse : 200mA, 2A,Mains supply : 230V ±10%, 50Hz
494Function Generator Trainerdemonstrating all basic concepts of Function Generator, Exclusive presentation and easy illustration of each block, Designed considering all safety standards, Low sine wave distortion, Low variation with temperature, Fault creation and troubleshooting, Onboard Frequency range display, Study of Electrical Waveforms generated by Function Generator,Study of Triangular Waveform Generation,Study of Sinusoidal Waveform Generation,Study of Square Waveform Generation,Study of Amplitude control,Study of TTL Waveform Generation,To create and identify different faults in the circuit and study their troubleshooting methods, Frequency Ranges : Selectable,1Hz to 10Hz,10 Hz to 100Hz,100Hz to 1kHz,1kHz to 10kHz,10kHz to 100kHz,Sine Wave Generation : By Wave Shaping Circuit,Switched Faults : 04 Nos.,Fuse : 350mA,Mains Supply :90-275V, 50Hz
495Power Supply Trainer with Real time appearance of components, Test points are provided in different sections of Power Supply, Demonstration bridge,Designed by considering all the safety standards,?Study of Transformers and its working,?Study of Two diode Full Wave Rectifier,?Study of Full Wave Bridge Rectifier ?Study of Demonstration Bridge,?Study of Ripple Factor and to calculate Ripple Factor of Half Wave, Full Wave and Bridge Rectifier,?Study of LC and ð filter,?Study of Bleeder Resistor and its effect on load current,?Study of Zener Diode as Regulator,?Study of Positive Regulated Supply,?Study of Negative Regulated Supply, ?Study of Adjustable Regulated Supply,?Study of Line Regulation ?Study of Load Regulation,Zener diodes : 10V, 5.6V,Regulators : +12V regulated,-12V regulated,1.8 to 17V adjustable,Load : 5kW variable with 1kW fixed resistance,Bleeder Resistor : 5kW variable with 1kW fixed resistance,Astable Multivibrator : 1Hz, 14Vpp, Transformer : Primary 0 to 220V,Secondary 18-0-18, 6-0-6 (500mA),Fuse : 500mA (slow blow, spare fuse is given in mains socket),Mains Supply : 230V ±10%, 50Hz
496(a) Study of the characteristics of P-N Junction diode (b) Study of characteristic of zenner diode
497A complete system to study the diode characteristics,Forward and reverse characteristics experiment can be performed on this trainer kit,Silicon, Germanium, Zener and Light Emitting Diode(LED) are provided with this system,Inbuilt Ammeter and Voltmeter are provided,Digital display for displaying voltage and current Different test points are provided,Study of V-I characteristics of Silicon Diode,Study of V-I characteristics of Germanium Diode, Study of V-I characteristics of Zener Diode,Study of V-I characteristics of Light Emitting Diode (LED),On Board DC power supply: +12V DC,Ammeter:-Range : 1µA to 200mA,Display : 3½ digit,Voltmeter:-Range : 1mV to 200V,Display : 3½ digit,Mains power : 230V AC ±10%
498(a) Construction of a half wave rectifier and full wave rectifier circuit ans study of output waveforms by CRO and calculation of efficiency and ripple factor
499Real time appearance of components,Test points are provided in different sections of power supply,Designed by considering all the safety standards,Study of Half-wave Rectifier, Study of Full-wave Center-tapped Rectifier, Study of Full-wave Bridge Rectifier, Calculation of Ripple Factor and Efficiency of various Rectifiers,Transformer Rating : 9V center tapped (300mA) approximate,Half wave Rectifier output : +4V DC approximate, Center-Trapped Rectifier : +8V DC approximate,Bridge Rectifier Output : +8V DC approximate,Filter : LC Type,Load : Resistive 220W, 0.5W,Mains Supply : 230V ±10%, 50Hz
500(b) Construction of an unregulated DC power supply using transformer full rectifier and capacitor filter and study of its output waveform by CRO
501Power Supply Trainer with Real time appearance of components, Test points are provided in different sections of Power Supply, Demonstration bridge,Designed by considering all the safety standards,?Study of Transformers and its working,?Study of Two diode Full Wave Rectifier,?Study of Full Wave Bridge Rectifier ?Study of Demonstration Bridge,?Study of Ripple Factor and to calculate Ripple Factor of Half Wave, Full Wave and Bridge Rectifier,?Study of LC and ð filter,?Study of Bleeder Resistor and its effect on load current,?Study of Zener Diode as Regulator,?Study of Positive Regulated Supply,?Study of Negative Regulated Supply, ?Study of Adjustable Regulated Supply,?Study of Line Regulation ?Study of Load Regulation,Zener diodes : 10V, 5.6V,Regulators : +12V regulated,-12V regulated,1.8 to 17V adjustable,Load : 5kW variable with 1kW fixed resistance,Bleeder Resistor : 5kW variable with 1kW fixed resistance,Astable Multivibrator : 1Hz, 14Vpp, Transformer : Primary 0 to 220V,Secondary 18-0-18, 6-0-6 (500mA),Fuse : 500mA (slow blow, spare fuse is given in mains socket),Mains Supply : 230V ±10%, 50Hz
502Study of frequency response of any one oscillator
503Experimentation with Hartley and Colpitt Oscilllator,Exclusive and compact design,Straight forward representation of Hartley and Colpitt Oscillators,+12V SMPS Adaptor provided with the trainer for power supply,Designed by considering all the safety standards,Study of design and functioning of Hartley Oscillator, Study of design and functioning of Colpitt Oscillator,Biasing Voltage : +12V DC,Design of Oscillators : Passive Elements with NPN Transistors
504Study of output characteristics of a common ameter transistor
505In-built Ammeter and Voltmeter are provided On board Fixed and Variable DC Power Supplies are provided,Digital display for displaying Voltage and Current,Three important characteristics of a Transistor can be performed,on this board :Input characteristic Output characteristic,Constant current transfer characteristic,Study of characteristics of PNP Transistor in Common Base Configuration and to evaluate Input resistance, Output resistance and Current gain.Study of characteristics of PNP Transistor in Common Collector Configuration and to evaluate Input resistance, Output resistance and Current gain., Study of characteristics of NPN Transistor in common Emitter Configuration and to evaluate Input resistance, Output resistance and Current gain., Study of characteristics of NPN Transistor in Common Base configuration and to evaluate Input resistance, Output resistance and Current gain., Study of characteristics of NPN Transistor in Common Collector configuration and to evaluate Input resistance, Output resistance and Current gain., Study of characteristics of PNPTransistor in Common Emitter Configuration and to evaluate Input resistance, Output resistance and Current gain.,Fixed DC Power Supply : +5V, -5V, +12V, -12V,Variable DC Supply : ±1.5V to ±11V,Transistor : BC547, BC557,Ammeter:Range : 1µA to 200mA, Display : 3½ digit,Voltmeter:Range : 1mV to 200V,Display : 3½ digit,Mains : 230V AC ±10%,
506Study of inverting and non inverting amplifier using opamp
507Comprehensive portable platform to perform over 15 experiments, In-built power supply, Breadboard, In-built function generator, Compact design,Study of Operational Amplifier as:Inverting Amplifier,Non - inverting Amplifier,Mains Power Supply : 90 - 270V ±10%, 50Hz (SMPS),Fixed DC Power Supply : +12V, Regulated-12V, Regulated+5V, Regulated-5V, Regulated,Variable DC Power Supply : +1.5V to +10V Regulated: -1.5V to -10V Regulated,Function Generator:Sine Wave Frequency : 1KHz to 100KHz,Frequency Control : 100KV, 10 turn Potentiometer, Amplitude : 0V to 5Vpp,Amplitude Control : 100KV, Single turn Potentiometer,Triangular Wave,Frequency : 1KHz to 100KHz, Frequency Control : 100KV, 10 turn Potentiometer,Amplitude : 0V to 5Vpp,Amplitude Control : 100KV, Single turn Potentiometer,Square Wave Frequency : 1KHz to 100KHz Frequency Control : 100KV, 10 turn Potentiometer Amplitude : 5Vpp, fixed Bread Board Dimension(mm) : 175 x 61 x 10 Distribution strips : 2 Distribution holes : 200 Terminal holes : 640, Op-Amp : IC uA741 (2 nos.) : All pins terminated on 2 mm,Banana Sockets,Supply Voltage : ±22V max.,DifferentialInput Voltage :±30V max.,Input Voltage : ±15V max.,Slew Rate : 0.5 V/µs (VCC = ±15V),Resistor Bank:SMD Resistance 1KV 1% 1/4W (5 nos.),SMD Resistance 10KV 1% 1/4W (5 nos.),SMD Resistance 100KV 1% 1/4W (5 nos.),Diode : Diode 1N 4007,Capacitor Bank : Electrolyte 1mf/63V,Disc 1nf/63V,Disc 10nf/63V,Disc 100nf/63V,Variable Resistance Bank:1KV Single turn Potentiometer (2 nos.),10KV Single turn Potentiometer (2 nos.),100KV Single turn Potentiometer (2 nos.), 1MV Single turn Potentiometer (2 nos.)Fuse : 500mA, slow blow
508Study of truth tables of different logic gates (AND, OR, NAND, NOR, XOR, XNOR)
509Exclusive and compact design,Straight forward representation of all logic gates +5V SMPS Adaptor provided with the trainer for power supply,Designed by considering all the safety standards,Study of AND gate and to verify its truth table,Study of OR gate and to verify its truth table,Study of NOT gate and to verify its truth table,Study of NAND gate and to verify its truth table,Study of NOR gate and to verify its truth table,Study of XOR gate and to verify its truth table,Study of XNOR gate and to verify its truth table,Input : +5V DC,Logic levels +5V : HIGH ( Logic 1 ),0V : LOW ( Logic 0 )
510EMMI LAB Analog Ammeters (AC and DC)
511Measuring Range: Microampere, mili-ampere, ampere (0-1, 3, 5,10, 20, 50, 100A), with reasonable accuracy range
512Analog Voltmeters (AC and DC)
513Measuring Range: Microampere, mili-ampere, ampere (0-1, 3, 5,10, 20, 50, 100A), with reasonable accuracy range
514Analog Multimeter
515Measurement of AC voltage 0-1000V, DC voltage-0-750V, current 0-10 A, Resistance
516Digital Multimeter
5174 ½ Digit, Provision to measure AC/DC parameters (Voltage & Current), 0-1000V DC, 750 V AC, 2/200mA to 20A Current Range, Continuity testing, Resistance, Diode testing, data hold and capacitance measurement facility
518Clamp-On Meters
519Clamp-On meter (Tong Tester) to measure Current and Voltages with digital display 1000V/600V (DC/AC), 100 A Rating
520Analog Wattmeter
521Portable Wattmeters, Dynamometer Type, Variouswattmeters with the current and voltage ratings ranges from: 0.5/1 A/5/10/15/30A, and 62.5/125/250/300/600/750/1000 V
5221-P Energy Meter
5231-Phase Energy Meter Analog type 1-Phase Energy Meter, 220V, 10A rating
5241-Phase Autotransformer (Variac)
525Input : 240V AC, 50 Hz Output :(0-270 V AC,0-5/10A)
5263-Phase Autotransformer,
527Input 440V AC, 50 Hz,Output(0-470 V AC,0-30A)
528CT/PT unit
529Trainer board including CT/PT to measure the power.• MainsSupply : 230V ±10%, 50Hz • Input : 230V AC Output : 0-270V AC • Current Rating : 5AAmmeter (2 nos.) • Display Resolution : 0.01A ACRange Min/Max : 0.1/5A • Voltmeter (2 nos.)Display Resolution : 1V AC • Range Min/Max : 10V/300V Wattmeter • Display Resolution : 1W Range Min/Max : 15/1500W • Current TransformerCT Ratio : 1:10 • Secondary Current Rating : 2A.
530De-sauty bridge
531Trainer kit of De-sauty bridge to measure the capacitance. • Each ETB must contains the required power Supply arrangement, componentshoused in a sturdy box/case, required meters for measuring voltage and currents, suitable terminals for connections and measurements, required connecting leads, components markings/symbols on experiment layout (circuit diagram) and manual.
532Maxwel bridge
533Trainer kit of Maxwel’s bridge to measure the inductance. • Each ETB must contains the required power Supply arrangement, componentshoused in a sturdy box/case, required meters for measuring voltage and currents, suitable terminals for connections and measurements, required connecting leads, components markings/symbols on experiment layout (circuit diagram) and manual.
534Wein’s bridge
535Trainer kit of Wein’s bridge to measure the frequency. • Each ETB must contains the required power Supply arrangement, componentshoused in a sturdy box/case, required meters for measuring voltage and currents, suitable terminals for connections and measurements, required connecting leads, components markings/symbols on experiment layout (circuit diagram) and manual.
536Kelvin double bridge
537Trainer kit of Kelvin double bridge to measure the low resistance. • Each ETB must contains the required power Supply arrangement, componentshoused in a sturdy box/case, required meters for measuring voltage and currents, suitable terminals for connections and measurements, required connecting leads, components markings/symbols on experiment layout (circuit diagram) and manual.
538Power Measurement by Two Wattmeter Method
539• Exclusive and rugged designed panel • Designed by considering all the safety precautions • Stand alone operation High quality meters • Diagrammatic representation for the ease of connections • Provided with an extensivemanual It should have following Technical Specifications : Mains Supply :Three Phase 415 V ±10 %, 50 Hz Load :R – L 3 Phase Variac 10A with wheels and terminal brought out on the plate Meters Used Wattmeters :500 W (2 Nos.) Voltmeter (MI) :500 V Ammeter (MI) :1 A MCB:10 A It should performed following experiments : • Measurement of Power Factor in a Three Phase Circuit • Measurement of Active, Reactive and Apparent Power in a Three Phase Circuit Measurement of Three Phase Parameters • Software Solution for Classroom/ laboratory Learning and Consists of Simulation for better understating of concepts of Basic Electrical and Power Electronics (Single end-user), should also support explanations with mandatory rich content and theory also through videos, graphs, charts to understand fundamental concepts, FAQ, MCQ etc.
540Calibration of Energy meter
541• Single phase kWh Energy meter • Inbuilt Voltmeter, Ammeter, Watt meter as Standard meter for • calibration of Energy meter • Big font LCD (16 x 2) for use as Standard meter/Energy meter • calibration • Separate Seven Segment Display as Energy meter • Digital Calibration/ Operation using Keypad • Sockets are provided to Connect External Voltmeter, Ammeter • and Watt meter for Calibration • Default and User Calibration modes are provided to avoid errors • during Operation • 5 LED Operation Indicators It should have following Technical Specifications: Auxiliary Power Supply : 90 - 270V ±10%, 50Hz Standard meter Voltmeter Minimum/Maximum : 10/300V Ammeter Minimum /Maximum : 0.1/5A Watt meter Minimum/Maximum:10/1500W Energy meter Display Resolution:0.001kWh Frequency: 50HzFuse : 250mA (2 Nos.) 5A (4 Nos.)AC/DC Load: Mains Supply :AC / DC, 230V ±10% Load Range :0 - 1.2 kW, in steps of 100W Load Type : Resistive (Lamp Load) Ammeter (MI):10A Experiments that can be performed: • Study the connection of Voltmeter, Ammeter & Watt meter for Power measurement of load in Transmission line • Study the connection of Energy meter in Transmission line • Measurement of Energy in kWh • Calibration of Energy meter using inbuilt Watt meter • Calibration of Energy meter using inbuilt Voltmeter & Ammeter • Calibration of Energy meter using Analog Watt meter • Calibration of Energy meter using Analog Voltmeter & Ammeter • Experiments on effect of wrong Calibration on Energy meter
542Optical Transducer
543Transducers: 4 Nos. Photoconductive Cell Photovoltaic Cell Phototransistor PIN Photodiode Light Source :Filament Lamp Signal Conditioning Circuitry : Power Amplifier Current Amplifier DC Amplifier Comparator Electronic Switch Buffer Input Circuits : Rotary & Slide Potentiometers Output Circuits : Relay LED Interconnections : 2 mm banana sockets Power Consumption : 2 VA (approximately) Product Tutorial : Online on www.ScientechLearning.com Dimensions (mm) : W 326 x D 252 x H 52 Power Supply : 100V - 240V AC, 50/60Hz Weight : 1.5Kg (approximately) Operating Conditions : 0-40 C, 85% RH Included Accessories : Mains cord : -1 no TechBook Power Supply: -1no. Patch cords 16” (2mm): -8nos. Patch cords 8” (2mm) : -6nos.
544Temperature transducer
545Transducers: 4 Nos. N.T.C. Thermistor Platinum R.T.D. K Type Thermocouple IC Temperature Sensor Heating Element : Wire wound resistance 47W, 10 W Signal Conditioning Circuitry : Instrumentation Amplifier X100 Amplifier DC Amplifier Comparator Electronic Switch Input Circuits : Rotary & Slide Potentiometers Output Circuits : Relay Buzzer Interconnections : 2mm banana sockets Mains Supply : 100V-240 V, AC, 50/60 Hz Power Consumption : 2 VA (approximately) Dimensions (mm) : W 326 × D 252 × H 52 Weight : 1.5Kg (approximately) Learning Material : Online on www.ScientechLearning.com Operating Conditions : 0-40 C, 85% RH Included Accessories : Mains cord : 1no. TechBook Power Supply : 1no. Patch Cord 16” (2mm) : 8nos. Patch Cord 8” (2mm) : 7nos. Transducers: 4 Nos. Photoconductive Cell Photovoltaic Cell Phototransistor PIN PhotodiodeLight Source :Filament Lamp Signal Conditioning Circuitry :Power Amplifier Current Amplifier DC Amplifier Comparator Electronic Switch Buffer Input Circuits : Rotary & Slide Potentiometers Output Circuits : Relay LED Interconnections : 2 mm banana sockets Power Consumption : 2 VA (approximately) Product Tutorial : Online on www.ScientechLearning.com Dimensions (mm) : W 326 x D 252 x H 52 Power Supply : 100V - 240V AC, 50/60Hz Weight : 1.5Kg (approximately) Operating Conditions : 0-40 C, 85% RH Included Accessories : Mains cord : -1 no TechBook Power Supply: -1no. Patch cords 16” (2mm): -8nos. Patch cords 8” (2mm) : -6nos.
546Rheostats
547Power ratings: 100-2500W 0.3 -25kOhm, up to 40 A ratings, with standard tolerance and temp. coefficient limits.
548Function Generator
549• 25 MHz Sine, Square 10 MHz • 2 Channels • Sampling rate: Min 125 Msa/s • Memory: Min 2 MPoints • Harmonics adding facility: Min 8th order • Min 150 types of various signal should be stored internally for study of medical waveforms,automotive waveforms,math wave forms • Display: Min 3.5 Inch color with touch screen • Interface: USB
550LCR-Q Meter
5514 digit LED Display , Auto ranging Basic Accuracy :0.25% Resistance : 0.001 O to 100 M Ohm , Inductance : 0.1uH to 9999H , Capacitance : 0.1pF to 999uF , Q : 0-99
552Digital Storage Oscilloscope
553• DC to 40 MHz • No. ofAnalog Channels: 04 • Min Sampling rate: 1 GSa/s • Memory : Min 15 Mpoints • Display: Min 5.7 Inch • Interface: USB and LAN • 04 nos. Probe of min 100 MHz available • Math Function should be available • Should be with advance serial bus trigger and decoding functions including RS232/UART, I2C and SPI
5541-Phase & 3-Phase Resistive Load
555240/440V, 5-20A, up to 10kW loading
5561-Phase & 3-Phase Inductive Load
557Single Phase Operation Voltage: 240V AC ±10%, 50Hz, Current: 15A, Power :3.5 kVAr, Loading steps: upto 30, MCBs Current rating 10A (SP), No. of MCBs: 30 Nos. Three Phase Star Operation Voltage: 415V AC ±10%, 50Hz, Current: 5A (per Phase), Power:3.5 kVAr Loading steps :5 (per Phase), MCBs (as a switch) 10A (SP) Three Phase Delta Operation Voltage: 415V AC ±10%, 50Hz, Current 15A (per Phase), Power: 10kVAR Loading steps: 5 (per Phase), MCBs: 10A (SP)
5581-Phase & 3-Phase Capacitive Load
559Mains Supply 230V AC ±10%, 50Hz (Single Phase) 415V AC ±10%, 50Hz (Three Phase) Current :4.6A each phase (in Star connection), 13A each phase (in Delta connection) Star/Delta Switch 415V, 32A, MCB 16A (Four Pole) 1 No., 10A (One Pole) 30 No.
560Earth Tester kit (digital Display)
561Earth Tester Kit with 3 ½ digit display Along with Test Leads x 1 Set (Red, Yellow, Black), Earthing Spikes (Rods) x 3, Hammer x 1, Carrying Case.
562Digital Insulation Tester (Meggar)
563(1000/2500V Test Voltage), 0.1Mohm to 100 G Ohm range, 3 ½ digit display Along with test leads, adapter and carrying case
564Screw Driver Set
565Screw drivers set for carrying our electrical & electronics related work
566Tool Kit
567Complete electrical tool kit housed in a suitable carrying case comprising of various electrical tools (including spanners and pliers, LN keys etc.) to carry out electrical maintenance job.
568Display boards/Charts
569Display boards /charts showing the description of various experiments/equipment features as per the syllabus
570Drilling machine
57126mm, 1000-1300 RPM, 800-1200 W, 1-phase AC supply Make: Black & Decker/ Bosch/Equivalent
572LINEAR CONTROL SYSTEM LAB Speed Torque Characteristics of AC Servo Motor Trainer
573Motor : Two phase ac servo motor ( 1500RPM )housed in Aluminum case for Cool operation Sensor : Electronic speed sensor with RPM Display upon panel meter,Loading arrangement : PMDC motor for loading(12V/1A) ,Switch : One for variable isolated (on/off through separate switch) supply for AC servomotor with speed control One for DC supply (on/off through switch) with potentiometer to vary PMDC motor current.,Display : Digital ammeter for load current Digital RPM meter for speed,Observation : Sockets for measure control Winding voltages(DC bias voltages),Power supply : Built in IC regulated power Supplies,Cabinate : Housed in rigid MS powder With moulded frame,Mains : 230V/50Hz AC,Dimension : 410x260x160mm ( approx.),Instruction manual : one
574Speed Torque Characteristics of DC Servo Motor Trainer
575Motor : Separately excited DC servomotor housed in separate rigid MS powder coated cabinate with moulded frame having front side see through cover,Loading arrangement : Belt and pulley loading for torque measurement having high precision spring balance to read load separately adjustable with lead screw motion.,Display : Two digital meters (selected through switch) to take readings of volt and current for field and armature Digital RPM meter,DC supply : Separate field and armature dc supply (current protected),Power supply : Built in IC regulated powerSupplies,Cabinate : Housed in rigid MS powder With moulded frame,Mains : 230V/50Hz AC,Dimension : 410x260x160mm ( approx.),Instruction manual : one, Software Solution for Classroom/ laboratory Learning and Consists of Simulation for better understating of concepts of Basic Electrical and Power Electronics (Single end-user), should also support explanations with mandatory rich content and theory also through videos, graphs, charts to understand fundamental concepts, FAQ, MCQ etc.
576Synchro Transmitter and Receiver
577Transformer Rating:100V AC, 1 amp (Rotor winding Supply) Digital Voltmeter:0-400 V AC max. Power Supply:230V ± 10%, 50Hz/60HzDimension:W 430 X D 260 X H 100Weight:4.5 kgs (approximately)oOperating Conditions:0-40C, 85% RH Included Accessories:Patch cord 14" (4mm)-10 nos.Mains cord-1 no.Calibrated dials for reference and output position•Switch for transmitter and Receiver rotor supply•Synchro Transmitter and Receiver rotor terminals onboard•Synchro Transmitter and Receiver stator terminals onboard.AC Voltmeter to measure stator and rotor voltagesOn/Off Touch SwitchSensitive, linear, stable and accurateEasy to operate
578Control System Simulator
579Variable Voltage:-10V to +10VUnit Step SignalSquare Wave :100HzRamp Wave:100HzParabolic Wave:100HzResistance Bank:100R, 1K, 10K, 10K, 50K, 100KInductor Bank:1µH, 680µH, 10mH, 10mH, 68mH, 68mH Capacitor Bank:1nF, 10nF, 10nF, 100nF, 1µF, 1µF Dimensions (mm) :W 326 x D 252 x H 52Power Supply :100V - 240V AC,50/60HzWeight :1.5Kg (approximately), Operating Conditions:0-40C, 85% RHIncluded Accessories:Patch cord 8" (2mm)-10nos.Patch cord 12" -6 nos.Mains cord-1no
580Lead Lag Compensation Network
581Frequency Counter:0 Hz - 50 KHzSquare Wave Generator:0 Hz - 2 KHz2 mm interconnection sockets : 16Power Consumption:1.6 VA (Approximately)Test Points :17 nos Dimensions (mm) :W 326 x D 252 x H 52Power Supply :110V - 260V AC, 50/60HzWeight :1.5Kg (Approximately)oOperating Conditions:0-40C, 85% RHIncluded Accessories:Patch cords16” (2mm) - 5 nos.Mains cord-1no.TechBook Power Supply-1no. Digital FrequencyCounter ,Square Wave Generator,Precise Signal Conditioning,Sensitive, linear, stable and accurate Easy to operate ,Rugged and compact ,Functional Blocks indicated on board mimic,2 mm socket for interconnection,Test points at various blocks to measure and observe the signals,eManual describing working along with detailed experiment descriptions
582Magnetic Amplifier
583Two saturable reactors in one frame, Two Rectifiers, Fixed Resistive load , DC bias voltage. One potentiometer. Two digital meters (IC & IL). IC regulated power supply for complete circuitry. 220V ±10%, 50Hz mains operated. User’s Manual with patch cords.
584Stepper Motor Controller with Microcontroller
585TTL circuit for single stepping & free running mode frequency 10-100Hz,Wobble mode,Direction selector,LED indicators for phase sequence,µPinterface,Calibrated dial for position monitoring,Position pick up by servo potentiometer,IC regulated power supply for complete circuitry,220V ±10%, 50Hz mains operated,User""s Manual with patch cords,STEPPER MOTOR:Power : 12V/1A,Torque : 2.0/3.0 kg/cm,Step Angle : 1.8 degreeSmall stepper motor fitted with calibrated dial and servo potentiometer in see through cabinet. The main unit should have a motor controller, pulse sequence generator, variable frequency square wave oscillator, single step mono pulsar and wobbling signal to observe dynamic response. The unit can be interface with µPkit, Software Solution for Classroom/ laboratory Learning and Consists of Simulation for better understating of concepts of Basic Electrical and Power Electronics (Single end-user), should also support explanations with mandatory rich content and theory also through videos, graphs, charts to understand fundamental concepts, FAQ, MCQ etc.
586PID Controller
587Proportional Band :5% to 55%.Integrator :1 msec to 11 msec ON/OFF controller :ON = 12 V, OFF = -12 V On board Generator :Square Wave & Triangular Wave Generator of 0-156 Hz, Two Variable DC Supply +6V,+10VInterconnections :2 mm socket Test Points :5 nos Dimensions (mm) :W 326 x D 252 x H 52Power Supply :100V - 240V AC, 50/60Hz Operating Conditions:0-40 C, 85% RH Included Accessories :Patch cord 8”(2mm)-14 nos.Patch cord 12” (2mm)- 6 Nos. Mains cord-1no.TehBook Power Supply-1 no. Proportional,Integral and Derivative functions can be checked on same board ( configurable as P, I, D, PI, PD, PID ), ON/OFF Controller, Square and triangular wave with variable frequency for testing PID ,Variable DC for set point ,Error detector ,1st 2nd order system & II order system In built power supply, Dead zone and disturbances generator, Voltmeter for DC measurement ,Signals can be observed and measured at various blocks,
588Power Supply
589Programmable Linear DC Power Supply - Numbers of Channels : 3 - Channel 1 [Voltage/Current: 0 to 30V/0 to 3A] & total power up to 195W - Channel 2 [Voltage/Current: 0 to 30V/0 to 3A] & total power up to 195W - Channel 3 [ Voltage/Current: 0 to 5V/0 to 3A] & total power up to 195W - Low ripple and noise: <350µVrms/2mVpp - Excellent linear regulation rate and load regulation rate - Fast transient response time: <50µs - Some channels are isolatedStandard OVP/OCP/OTP protection functions - Standard timing output -Built-in V,A,W measurements and waveform display - Independent control for each channel -Support more advanced functions: timer and delay output(standard) -Interfaces: USB - Display 3.5 inch Color TFT LCD Manual with operating instructions , theoretical and practical details Regulated Programmable Multi-rangeDC power supplies
590DSO/MSO
591- 4 Channel - Bandwidth 50 MHz - Sampling Rate 1GS/s - Colour LCD Display With probes, and power supply cord
592Digital Multimeter
5934 ½ Digit, Provision to measure AC/DC parameters (Voltage & Current), 0-1000V DC, 750 V AC, 2/200mA to 20A Current Range, Continuity testing, Resistance, Diode testing, data hold and capacitance measurement facility
594Screw Driver Set
595Screw drivers set for carrying our electrical & electronics related work
596POWER SYSTEM & ENERGY LAB Power quality Analyzer (Harmonic Analyzer)
597Power Quality Analyzer/Harmonic Analyzer For 3-Phase System ( 3P4W, 3P 3W, 1P 2W) Display of Multi-parameters on One Screen To measure, display & Record the following Electrical Parameters: Voltage, Currents, Power (kW, kVA, kVAr), Energy, PF, Frequency, THD, Dips & Swells, Outage, Transients, RMS, Peak, Crest Factor, Average & Maximum Demand. Other features required are - Display of 50 Harmonics in one screen with waveforms & peak Value - Inbuilt Memory for data recording - Data Hold & Zooming facility - Optical isolated RS232/USB interface - Voltage & Current Probes - Battery Charger/Adapter - OS Software Carrying case & manual etc.
598Analog Voltmeters (AC and DC)
599Measuring Range: Microvolt, mili-volts, volts (0-1, 3, 5,10, 20, 50, 100, 300, 500, 1000 V) with reasonable accuracy range
600Analog Ammeters (AC and DC)
601Measuring Range: Microampere, mili-ampere, ampere (0-1, 3, 5,10, 20, 50, 100A), with reasonable accuracy range
602Analog Wattmeter
603Portable Wattmeters, Dynamometer Type, Variouswattmeters with the current and voltage ratings ranges from: 0.5/1 A/5/10/15/30A, and 62.5/125/250/300/600/750/1000 V/1500/3000V
604Digital Multimeter
6054 ½ Digit, Provision to measure AC/DC parameters (Voltage & Current), 0-1000V DC, 750 V AC, 2/200mA to 20A Current Range, Continuity testing, Resistance, Diode testing, data hold and capacitance measurement facility
606Clamp-On Meters
607Clamp-On meter (Tong Tester) to measure Current and Voltages with digital display 1000V/600V (DC/AC), 100 A Rating
608Experimental trainer boards (Switchgear & Protection Lab)
609Each ETB must contains the required power Supply arrangement, componentshoused in a sturdy box/case, required meters for measuring various parameters, suitable terminals for connections and measurements, required connecting leads, components markings/symbols on experiment layout (circuit diagram) and manual. Software Solution for Classroom/ laboratory Learning and Consists of Simulation for better understating of concepts of Basic Electrical and Power Electronics (Single end-user), should also support explanations with mandatory rich content and theory also through videos, graphs, charts to understand fundamental concepts, FAQ, MCQ etc.The experiments to be covered are: 1. To plot time-current characteristics of an IDMT relay. 2. To plot time current characteristics of Electromagnetic type over-current relay. 3. Study of the performance and operation of a three phase over-current andearth fault static relay. 4. Symmetrical fault level analysis on a d.c.network analyzer. 5. Unsymmetrical fault level analysis on a d.c. network for various type of faults. 6. To study transformer differential protection. 7. To study the magnetization characteristics of C.T 8. To study the problems associated with C.T. magnetization. 9. Performance and study of Merz-Price protection Scheme. (9*2)
610MSO
611100 MHz Mixed Signal Digital Oscilloscope with Built in 25MHz Arbitrary Waveform Generator & PowerScope Module - Analog channel bandwidth: 100 MHz, 4 analog channels, 16 digital channels - Real-time sample rate up to 1 GSa/s - Memory depth up to 12 Mpts - Up to 30,000 wfms/s waveform capture rate - Built-in dual-channel 25 MHz function/arbitrary waveform generator - Interfaces: USB - Display7 inch Color TFT LCD - PowerScope Module for Floating measurements with completely isolated inputs - Manual with operating instructions , theoretical and practical details
612Multirange DC Regulated Power Supply
613Programmable Linear DC Power Supply - Numbers of Channels : 3 - Channel 1 [Voltage/Current: 0 to 30V/0 to 3A] & total power up to 195W - Channel 2 [Voltage/Current: 0 to 30V/0 to 3A] & total power up to 195W - Channel 3 [ Voltage/Current: 0 to 5V/0 to 3A] & total power up to 195W - Low ripple and noise: <350µVrms/2mVpp - Excellent linear regulation rate and load regulation rate - Fast transient response time: <50µs - Some channels are isolatedStandard OVP/OCP/OTP protection functions - Standard timing output -Built-in V,A,W measurements and waveform display - Independent control for each channel -Support more advanced functions: timer and delay output(standard) -Interfaces: USB - Display 3.5 inch Color TFT LCD Manual with operating instructions , theoretical and practical details
614Function Generator
615Spec.: Range 0.3 Hz to 3 MHz with Sine , Square , Triangle , DC , 15 MHz Frequency Counter , DC Offset adjustment CMOS and TTL Trigger Output Internal Sweep and External FM Modulation Distortion Factor < 0.5% Square Wave Rise time typ. 70 ns
616Wind Energy trainer
617The trainer should have following Technical Specifications : Wind Turbine Setup :Contain 3 blades Maximum Open Circuit Voltage:3 V Maximum Short Circuit Current:250 mA Voltmeter:0-10 V Ammeter:0-500 mA Potentiometer:5 KO 1 AA Rechargeable NiCd Battery:1.2 V Lamp :1.2 V, 250 mA Fan :1.5 V, 250 mA FM Band Radio:3V The trainer should performed following experiments : ? Calculation of voltage and current of wind energy based DC supply with change in shape of blades. ? Calculation of voltage and current of wind energy based DC supply with change in angle of blades. ? Calculation of voltage and current of wind energy based DC supply with change in direction of wind. ? Calculation of voltage and current of wind energy based DC supply with change in wind pressure. ? Application of wind energy based DC supply in domestic purposes : a. Charging of batteries both on load and no load conditions. b. Operating lamp, fan and radio.
618Hybrid Solar & Wind Energy Traine
619Hybrid Solar & Wind Energy Trainer The trainer should have following features : • On-board Voltmeter and Ammeter • Battery charging using both Solar and Wind energy • Weather-proof solar cells The trainer should have following Technical Specifications : Solar Panel :Consists of 6 solar cells Solar Cell DC Voltage :2V Max., DC Current :Up to 150mA Wind Turbine Setup:Contains 3 blades Open Circuit DC Voltage:2.5V to 3.5V Short Circuit DC Current:Up to 220mA DC Voltmeter :0-10V DC Ammeter :0-500mA Potentiometer :5KO Rechargeable Ni-Cd Battery :1.2V Lamp:3V Fan:3V FM Receiver :3V The trainer should performed following experiments : • Study of the voltage and current of the solar cells in series and parallel combinations • Study of current-voltage characteristic and the power curve to find the maximum power point (MPP), To calculate the efficiency (h) of the solar cell • To study the application of solar cells in charging of Ni-Cd battery • To Study of the application of solar cells of providing electrical energy to the domestic appliances such as lamp, fan and radio • Installation of Wind Turbine Setup and measurement of wind Energy based DC Voltage and Current Measurement of voltage and current of wind energy based DC supply with change in angle of blades • Measurement of voltage and current of wind energy based DC supply with change in direction of wind.Measurement of voltage and current of wind energy based DC supply with change in speed of wind imposed on the blades • Study of the application of wind energy based DC supply in charging of Ni-Cd battery. Study of the application of wind energy based DC supply of providing electrical energy to the domestic appliances such as lamp, fan and FM receiver.
620Hydro Turbine Energy Generator
621The trainer should have following features : • Good quality Pelton wheel in double hemispherical cup/bucket should be provided. • Compact Hydro Turbine should be provided with digital voltage and current measurement. • Various load applications like resistive bulb and fan should be provide with the product. • Robust and transparent casing to observe Pelton wheel rotation with changing water flow • 304 grade SS tank for storing water The trainer should have following Technical Specifications : Water Pump :0.5HP, Single Phase, 50Hz Ammeter :0 to 2A Voltmeter :0 to 100V Load Resistance:50Ù DC output :20V, 1A Pelton wheel PCD:100mm Nozzle Diameter:5mm
622CT Trainer
623CT Trainer/Testing Kit: Measurement of % ratio error and Phase Angle of given CT by Comparison. Model No : Scope of Learning: • Testing of C.Ts by Comparison method. • Determination of Ratio and Phase angle Error. Consists of a Panel Closed type with front Hylam sheet. • 2ft ht x 4 ft wd x 200mm depth. Standard & Under test CTs of Different Ratio. 1 Phase Auto Transformer------8 Amps. Phase shifting Transformer --- 1no. Digital Voltmeter-------500 Volts AC----01 no. MECO Digital Ammeter--------20 Amps AC-----02 no. MECO Analog Panel mounted wattmeter (0-250V, 5 Amps) ----02 nos. MCB Protection Neon Indications-------LED. Terminals BTI – 30. Patch cords.
624Writing Board
625Writing Board for lab Class: Green Colour, magnetic feature, Chrome plated aluminium frame, Ceramic board material, Size 6"x4"
626Solar array Simulator: Bidirectional Programmable DC Power Supply (6kW, 500V, 40A)
627DC Output and Load Ratings: Maximum 6 kW Maximum Output voltage: 0-500 V Current: 0-40 A DC Output Modes: CV, CC, I-V simulation, adjustable output impedance Feature set: Bidirectional enegy flow between the DUT and the AC grid Source and Sink function Built-in arbitrary waveform generator Adjustable output impedance Support solar panel I-V curves simulation Stand-alone power up to 120 kW, expandable in parallel up to 1152 kW High power density design provides 18 kW in 3U space High resolution, high precision and high stability Built-in voltage curves comply with DIN 40839, ISO-16750-2/ISO21848 automotive standards Parallel connection Power failure protection OCP/under current protection /OVP/OTP/OPP/UVP, grid fault protection and fault storage Connectivity: Built-in USB/CAN/LAN/digital IO interface Optional GPIB, Analog and RS232
628LCR Meter
6296 digit reading resolution. Low cost, high performance, small size Max. 100 kHz test frequency. Soft power switch. DCR, 50mV-2V programmable test level, Resolution 10micro Ohm, Maximum test speed: 13 ms/time. Selectable 30 ohm /100 ohm signal source impedance, Built-in comparator, 10 bins sorting and count function, File storage and program update through U disk. RS232, RS485, USB, HANDLER, GPIB interface, Operating Temperature - 0 - 40°C, Operating Humidity - < 90 % RH, (Inductance Range 0.00001µH to 99.9999 kH)
630ELECTRONICS & ADVANCE INSTRUMENTATION LAB Experimental Trainer Boards
631Each ETB must contains the required power Supply arrangement, componentshoused in a sturdy box/case, required meters for measuring various parameters, suitable terminals for connections and measurements, required connecting leads, components markings/symbols on experiment layout (circuit diagram) and manual. Software Solution for Classroom/ laboratory Learning and Consists of Simulation for better understating of concepts of Basic Electrical and Power Electronics (Single end-user), should also support explanations with mandatory rich content and theory also through videos, graphs, charts to understand fundamental concepts, FAQ, MCQ etc., The experiments to be covered are: 1.Experiment to study characteristics of DIAC, SCR and TRIAC. 2.Experiment to study characteristics of transistor and MOSFET. 3.Experiment to study R and R-C firing circuits. 4.Experiment to study UJT firing circuit. 5.To Study the three phase half wave uncvontrolled rectifier with R and R-L load, in common Cathode configuration and common anode configuration and also to observe the effect of freewheeling diode 6.To study three-phase full wave controlled rectifier operation with R and R-L load and observe its input/output Wave form. 7.Experiment to study dc chopper. 8.Experiment to study single-phase cycloconverter characteristics. 9.To study single-phase full wave controlled rectifier using SCRwith R and R-L load and observe its input/output Waveform with and without freewheeling (commutating) diode. (9*2=18)
632Experimental Trainer Boards
633Each ETB must contains the required power Supply arrangement, components housed in a sturdy box/case, required meters for measuring various parameters, suitable terminals for connections and measurements, required connecting leads, components markings/symbols on experiment layout (circuit diagram) and manual. Software Solution for Classroom/ laboratory Learning and Consists of Simulation for better understating of concepts of Basic Electrical and Power Electronics (Single end-user), should also support explanations with mandatory rich content and theory also through videos, graphs, charts to understand fundamental concepts, FAQ, MCQ etc. The experiments to be covered are: 1. To study triggering circuits for thyristor: Resistor triggering circuit; R-C triggering circuit. 2. To Study Single phase semiconverter in common cathode and common anode configuration with R anf R-L Load and also observe the effect of freewheeling diode 3. To Study of three phase full converter with R and R-L load. 4. To study SCR Half Wave and Full Wave Bridge Controlled Rectifier Output characteristics. 5. To study three Phase Full-Wave Uncontrolled Rectifier Operation with R and R-L Load and observe its input/output Characteristics. 6. To study Single Phase Cycloconverter output characteristics. 7. Series operation of SCR’s. 8. Parallel operation of SCR’s. 9. Lamp-Dimmer Using diac&triac with Lamp Load. (9*2=18)
634Experimental Trainer Boards
635Each ETB must contains the required power Supply arrangement, components housed in a sturdy box/case, required meters for measuring various parameters, suitable terminals for connections and measurements, required connecting leads, components markings/symbols on experiment layout (circuit diagram) and manual. Software Solution for Classroom/ laboratory Learning and Consists of Simulation for better understating of concepts of Analog and Digital Electronics (Single end-user), should also support explanations with mandatory rich content and theory also through videos, graphs, charts to understand fundamental concepts, FAQ, MCQ etc.The experiments to be covered are: 1. Verify truth tables of AND,OR, NOT, NAND,NOR and XOR gates. 2. Implement(i)half adder(ii) full adder using AND–OR gates. 3. Implement full adder using NAND gates as two level realizations. 4. Implement full subtractor using 8 to1multiplexer. 5. Verify truth tables ofRS &JK flip flops and convert JKflip flops into D type & T type flip flops. 6. Use 555 timer as(i) monostable(ii) as table multivibrator. 7. (a) Use of 4-bit shift register for shift left and shift right operations. (b) Use4-bit shift register as a ring counter. 8. Implement mod–10 counter and draw its output wave forms. (8*2=16)
636Digital Multimeter
6374 ½ Digit, Provision to measure AC/DC parameters (Voltage & Current), 0-1000V DC, 750 V AC, 2/200mA to 20A Current Range, Continuity testing, Resistance, Diode testing, data hold and capacitance measurement facility
638Ammeter
639Measuring Range:mili-ampere, ampere (0-100 mA), with reasonable accuracy range
640Experimental Trainer Boards
641Each ETB must contains the required power Supply arrangement, componentshoused in a sturdy box/case, required meters for measuring various parameters, suitable terminals for connections and measurements, required connecting leads, components markings/symbols on experiment layout (circuit diagram) and manual. The experiments to be covered are: 1. Addition and subtraction of two 8-bit numbers with programs based on different addressing modes of 8085A. 2. Addition and subtraction of two 16-bit numbers. (Using 2’s complement method, also programs which access numbers from specified memory locations.). 3. Multiplication of two 8-bit numbers using the method of successive addition and Shift & add. 4. Division of two 8-bit numbers using the method of successive subtraction and shift & subtract. 5. Block transfer and block exchange of data bytes. 6. Finding the smallest and largest element in a block of data. 7. Generation of Fibonacci Series.. 8. Program controlled data transfer using 8255 PPI. 9. To INPUT data bytes from peripheral port and to store them in memory. (9*2)
642DSO/MSO
643100 MHz Mixed Signal Digital Oscilloscope with Built in 25MHz Arbitrary Waveform Generator & PowerScope Module - Analog channel bandwidth: 100 MHz, 4 analog channels, 16 digital channels - Real-time sample rate up to 1 GSa/s - Memory depth up to 12 Mpts - Up to 30,000 wfms/s waveform capture rate - Built-in dual-channel 25 MHz function/arbitrary waveform generator - Interfaces: USB - Display7 inch Color TFT LCD - PowerScope Module for Floating measurements with completely isolated inputs - Manual with operating instructions , theoretical and practical details
644Power Supply
645Programmable Linear DC Power Supply - Numbers of Channels : 3 - Channel 1 [Voltage/Current: 0 to 30V/0 to 3A] & total power up to 195W - Channel 2 [Voltage/Current: 0 to 30V/0 to 3A] & total power up to 195W - Channel 3 [ Voltage/Current: 0 to 5V/0 to 3A] & total power up to 195W - Low ripple and noise: <350µVrms/2mVpp - Excellent linear regulation rate and load regulation rate - Fast transient response time: <50µs - Some channels are isolatedStandard OVP/OCP/OTP protection functions - Standard timing output -Built-in V,A,W measurements and waveform display - Independent control for each channel -Support more advanced functions: timer and delay output(standard) -Interfaces: USB - Display 3.5 inch Color TFT LCD Manual with operating instructions , theoretical and practical details
646Function Generator
647Spec.: Range 0.3 Hz to 3 MHz with Sine , Square , Triangle , DC , 15 MHz Frequency Counter , DC Offset adjustment CMOS and TTL Trigger Output Internal Sweep and External FM Modulation Distortion Factor < 0.5% Square Wave Rise time typ. 70 ns
648Misc. Components/Accessories
649Electrical accessories required to charge (give electrical supply) to the various working tables/workbenches and other electrical machines installed in the lab plus electrical accessories and electronic components (Lumpsum Qty)
650Screw Driver Set
651Screw drivers set for carrying our electrical & electronics related work
652Tool Kit
653Complete electrical tool kit housed in a suitable carrying case comprising of various electrical tools (including spanners and pliers, LN keys etc.) to carry out electrical maintenance job.
654White Board
655Magnetic Whiteboards, Frame Material: Aluminum, Scratch Resistant, Chemical Resistant, Stain Resistan
656ELECTRICAL SIMULATION LAB Software
657Simulation Software for Lab (Matlab, other software related to EE), License and CD (30 User)
658White Board
659Magnetic Whiteboards, Frame Material: Aluminum, Scratch Resistant, Chemical Resistant, Stain Resistan
660Printer
661All in One Printer System for Lab Office
662Projector
663Automatic keystone correction, Built-in speaker, Horizontal and vertical keystone correction Full HD Projector – 3600 Lumens | 16000:1 Contrast Ratio | Interface: 2x HDMI, wireless LAN, USB, VGA | 1080p Native Resolution
664Projector Screen
665Wall mounted, Motorized projector screen made of high gain fabric. • Size:- 8 ft (Width) x 6 ft (Height) Picture in 16:9 Ratio Format, 120 Inch Diagonal Size • Anti UV coating to protect eyes • Supports 1080P Full HD, 3D and 4K technology
666All in one tool kit
6671-Piece Screwdriver, 1-Piece Hammer, 7-Piece Screwdriver Bits, 1-Piece Plier, 1-Piece Wrench and 1-Piece Measuring Tape
668ALL DEPARTMENTS - OFFICE & CLASSROOMS ITEMS Interactive Panels
669Screen size 98"", Panel type: IPS, Resolution: UHD 3840 × 2160 pixels Aspect ratio: 16:9, Brightness (typical): 350 nits, Contrast ratio (typical):1200:1 Dynamic contrast ratio: 30,000:1, Color depth: 10-bit, Response time: 8 ms Color gamut: 65% NTSC, Operation hours: 18 hours / 7 days, Orientation: Landscape, Light life (typical): 30,000 hrs Hardness: 9H tempered. Germ-resistant technology: Nano-ionic silver Anti-glare coating: Yes, Touch technology: TBD, Touch points: 20 Touch response time:< 8 ms, Memory | Storage: 2GB I 8GB HDMI (in | out): 3 × HDMI 2.0 | 1 × HDMI 2.0 DisplayPort (in | out): 1 × 1.1/1.2 | No VGA (in | out): 1 | 0 3.5 mm audio in (VGA): 1 USB-A: 5 × 2.0 + 1 × 3.2 Gen1 Slot-in PC (OPS):1 Stylus: 2 Remote Controller: 1 Wireless screen sharing: InstaShare 1 Account management: AMS Device management: DMS Quick access tool: Floating Tool Broadcast system: X-Sign Broadcast Ambient light sensor: Yes NFC: Yes
670Projector
671Projection System: 3LCD Technology, RGB liquid crystal shutter, LCD Panel: 0,61 inch with MLA (D10),Color Light Output: 3.400 Lumen- 2.200 Lumen (economy) In accordance with ISO 21118:2013 White Light Output: 3.400 Lumen - 2.200 Lumen (economy) In accordance with ISO 21118:2013, Resolution: Full HD 1080p, 1920 x 1080, 16:9 High Definition: Full HD, Aspect Ratio: 16:9 Contrast Ratio: 16.000 : 1, Light source: Lamp Lamp: UHE, 210 W, 6.000 h durability, 12.000 h durability (economy mode), Keystone Correction: Auto vertical: ± 30 °, Manual horizontal ± 30 ° Colour Video Processing: 10 Bits 2D Vertical Refresh Rate: 192 Hz - 240 Hz, Colour Reproduction: Upto 1.07 billion coloursThrow Ratio: 1,02 - 1,23:1, Zoom: Manual, Factor: 1,2 Lens: Optical, Screen Size: 30 inches - 300 inches, Projection Distance Wide/Tele: 1,02 m - 1,23 m ( 60 inch screen) Projection Lens F Number: 1,58 - 1,7, Projection Lens Focal Length: 14,06 mm - 16,82 mm, Projection Lens Focus: Manual, Offset: 14 : 1 SB Display Function: 2 in 1: Image / Mouse Interfaces: USB 2.0 Type A, USB 2.0 Type B, VGA in, HDMI in (2x), Composite in, Cinch audio in, Wireless Security: Kensington lock, Security cable hole, Password protection, 3D: No 2D Colour Modes: Dynamic, Cinema, Bright Cinema Other features: AV Mute Slide, Automatic keystone correction, Built-in speaker, Horizontal and vertical keystone correction, MHL audio/video interface, Quick Corner, Split-Screen-Function, Video Color Modes: Cinema, Dynamic, Game, Bright Cinema, AC 100 V - 240 V, 50 Hz - 60 Hz, 302? x 252 x 92 mm, 2.8 kg Normal: 37 dB (A) - Economy: 28 dB (A),Main unit, Power cable, Quick Start Guide, Remote control incl. batteries, User manual (CD), Warranty card Home Photo, Sports, Streaming, TV & Box sets, Ceiling Mounted, Desktop, Colour: White
672Projector Screen
673Size and Aspect Ratio: 100" diagonal, 16:9 View Size: 87"Wx48.8"H. Suitable for LED, LCD, and DLP projectors Electric motorized projector screen: Prewired power cord with integrated switch to regulate drop/rise settings OR radio frequency remote control for distant control. Premium PVC Matte White Scree: 160 degree large viewing angle provides a large viewing area; 1.1 gain Matte white screen is yellow-staining-free, wrinkle-free, and providing outstanding image reproduction
674White Mark Board
675Magnetic Whiteboards, Frame Material: Aluminum, Scratch Resistant, Chemical Resistant, Stain Resistan
676Photostat Machine: Multipurpose Type
677Multipurpose Type Photostat Machine, with Color print facility, 10/100/1000 Ethernet LAN connection with IPv4 and IPv6, Hi-Speed USB 2.0 printer to PC connections, Easy-access USB port for printing without a computer and upgrading the firmware (located near the control panel), IEEE 802.1 1b/g/n (NFC active type), Foreign Device Interface (FDI) Kit, 1.5 GB base memory (standard/maximum), 320 GB HP Secure High-Performance Hard Disk, 7 inch touchscreen control panel, Prints 25 pages per minute (ppm) on A4 and on letter-size paper, Prints 30 pages per minute (ppm) on A4 and on letter-size paper, Scans 45 images per minute (ipm) (mono) on A4 and letter-size paper, Copy up to 25 cpm on A4 and letter size paper, Automatic document feeder (ADF) (multiple pass duplex), 100-sheet document feeder output, Os supported windows,
678MULTIFUNCTION LASER PRINTER
679SYSTEM Specifications: 1. Speed (Color/Black-and-white): 45 ppm 2. Monthly duty cycle: upto 2,00,000 pages 3. Hard Drive/Processor/Memory: Minimum 128 GB SSD 4. Connectivity: Ethernet 10/100/1000 Base-T, High-speed USB 2.0 direct print, NFC 5. Controller Features: Unified Address Book, Remote Control Panel, Configuration Cloning, Fleet Orchestrator, Configuration Watchdog 6. Duplex printing: Yes 7. Configuration: 4*Toner (Black, Cyan, Magenta, Yellow) Copy and Print Specifications: 1. Resolution: Copy: Up to 600 x 600 dpi; Print: Up to 1200 x 2400 dpi 2. Page Description Language: Adobe PostScript 3, Adobe PDF, PCL 5c/PCL 6 3. Print Features: Print from USB, Print from Cloud Repositories (Dropbox, OneDrive, and Google Drive), Encrypted Secure Print, Job Identification, Booklet Layout, Store and Recall Driver Settings, Bi-directional Real-time Status, Scaling, Job Monitoring, Application Defaults, Two-sided Printing (as default), Hold All Jobs, Long Sheet (Banner) Printing, Print Around, Print on Alternate Paper; Imaging Security and infrared detection technology. 4. Mobile Connectivity: Near Field Communication (NFC), Wi-Fi Direct, Wi-Fi (802.11 b/g/n/ac), AirPrint (iOS) including iBeacon (Bluetooth) 5. Mobile Printing: Mopria Scan, Apple AirPrint, Android Print Service. 6. Print from USB: Allows walk-up printing from Type A USB port on front panel, Supports direct printing from computer via Type B USB port, Supported file formats: PDF, JPEG, TIFF, PS, PCL and Color jobs can be printed as black-and-white. 7. Reduction/Enlargement: Variable zoom from 25% to 400% in 1% increments. Scan Specifications: 1. Destinations: Scan to USB/Email/Network (FTP/SMB), HTTP, HTTPS, SFTP destinations; File Formats: PDF, PDF/A, JPEG, TIFF 2. Convenience Features: Scan Preview, Scan to Home, Searchable PDF, Single/Multi-Page PDF/TIFF, Password-protected PDF, Unified Address Book,Optical Character Recognition (OCR), Scan to Folder, 1-Touch Apps, TWAIN Support, Touchless Workflow Accelerators, Imaging Security and infrared detection technology. 3. Maximum Scan Area: 11 x 17 in./A3 Fax Specifications: Internet Fax, Fax Build Job, Network Server Fax Enablement, Fax Build Job Security Specifications: 802.1x, IPsec, HTTPS, SFTP and Encrypted Email, McAfee Embedded Control Whitelisting, Firmware Verification, McAfee ePolicy Orchestrator®, McAfee Enterprise Security Manager, LogRhythm SIEM, Splunk SIEM, Network Authentication, SNMPv3, SHA-256 Hash Message Authentication, TLS1.1/1.2/1.3, Security Certificates utilizing ECDSA, Automatic Self-signed Certificate, Cisco Identity Services Engine (ISE) integration, automated threat response through McAfee DXL/Cisco pxGrid integration, Local Authentication (Internal Database), FIPS 140-2.User Access and Internal Firewall, Port/IP/Domain Filtering, Audit Log, Access Control, User Permissions, Configuration Watchdog, TPM, Trusted Boot, Encrypted Storage Drive (AES 256-bit, FIPS 140-2), Job Level Encryption via HTTPS and Drivers, Signed Email, Common Criteria Certification (ISO 15408), Encrypted Secure Print, Imaging Security (copy, print, scan, email) with marking and infrared detection technology. Tray Specifications: 1. Capacity: minimum 500 sheets 2. Numbers: 2 3. Size: Tray 1: Custom Sizes: 5.5 x 7.2 in. to 11.7 x 17 in./140 x 182 mm to 297 x 432 mm (SEF) Tray 2: Custom Sizes: 5.5 x 7.2 in. to 12 x 18 in./140 x 182 mm to SRA3 (SEF) 4. Media Types: Bond, Card Stock, Card Stock Reloaded, Custom Envelopes, Glossy Card Stock, Glossy Card Stock Reloaded, Heavyweight Card Stock, Heavyweight Card Stock Reloaded, Heavyweight Glossy Card Stock, Heavyweight Glossy Card Stock Reloaded, Hole Punched, Labels, Letterhead, Lightweight, Lightweight Card Stock, Lightweight Card Stock Reloaded, Lightweight Glossy Card Stock, Lightweight Glossy Card Stock Reloaded, Plain, Plain-Reloaded, Preprinted, Recycled, Transparencies. Output Tray Specifications: 1. Stacking Tray Capacity: 500 sheets of 20 lb. bond/80 gsm – 8.5 x 11 in./A4 or 250 sheets of 20 lb. bond/80 gsm – 11 x 17 in./A3 2. Sizes: 3.5 x 3.9 in. to 11.7 x 17 in./89 x 98 mm to 297 x 432 mm OS: Compatible with latest OS available. Mandatory Feature: Installation and demonstration of product in the scope of bider. 3 year Warranty with supplies on delivery.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail