Providing Fhtc Of Package No Tn 12- 108 Inkodumudi Block Of Erode District Under Jjm 2022-23
Tender Value
45.40 Lakhs
Estimated cost
Bid Submission
27 Jul 2022
0 days left
EMD
46000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
kodumudi → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Providing Fhtc Of Package No Tn 12- 108 Inkodumudi Block Of Erode District Under Jjm 2022-23
BOQ
| Sl. No. | Item Description |
| 1 | Name of Work :Providing FHTC to Bharathy NagarHabitation H/O Ichipalayam Panchayat |
| 2 | PROVIDING FHTC |
| 3 | Supply and delivery ofPVC rigid pipes for potable water supplywith ISI 4985 / 2000marking with necessary couplers (or) bell ended pipes as specified in ISI, the required quantity of solvent cement and having the following working pressure. The cost of pipes should include loading, freight, transit insurance, incidental charges, packing, taxes and transportation charges upto stack yard in good condition etc., complete (the cost excluding unloading from lorries at stack yard and stacking which will be paid separately) and as directed by the TWAD Board Officers. |
| 4 | 90 MM PVC 4KSC PIPPE |
| 5 | 75 MM PVC 4KSC PIPPE |
| 6 | Supply and delivery of the following PVC Specials suitable for PVC Pipes including loading, freight, unloading, stacking at Stockyard , insurance etc., complete as per IS 10124/1982 Part -II and as directed |
| 7 | 90mm PVC Bend |
| 8 | 90mm PVC End Tee |
| 9 | 90mm PVC End Cap |
| 10 | 75mm PVC Bend |
| 11 | 75mm PVC Equal Tee |
| 12 | 75mm PVC End Cap |
| 13 | 63mm GI Gate Valve |
| 14 | II.Civil Works |
| 15 | Earth work excavation and depositng on bank within an initial lead of 10 m and initial lift 0 to 2 min Hard stiff clay, stiff block cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size bouldersfor laying pipeline in respect of following size of pipe with standard trench width and required depth including shoring, struting, balling out water wherever necessary and all other incidental works such as barricading, providing danger lights, labour for watch and ward,as oer standard specifications andas directed by the TWAD Board officers |
| 16 | 90 MM PVC 4KSC PIPPE |
| 17 | Lowering PVC rigid pipes and specials to trench and laying to proper grade and alignment, jointing with PVC couplers with cement paste as per standard specifications and as directed by theTWAD Board Officers. |
| 18 | For depth upto 2m |
| 19 | 90 MM PVC 4KSC PIPPE |
| 20 | 75 MM PVC 4KSC PIPPE |
| 21 | Refilling with excavated earth (other than sand) in respect of following sizes of pipeswateredwell rammed and consolidated etc.complete complying with standard specification for filling the trenches after the pipes and specials are laid, jointed and tested and as directed by the TWAD Board Officers. |
| 22 | 90 MM PVC 4KSC PIPPE |
| 23 | 75 MM PVC 4KSC PIPPE |
| 24 | Road Relaying charges |
| 25 | Restoring the Cut CC .Roadby Paver block |
| 26 | B.T Cutting |
| 27 | FHTC DISTRIBUTION LINE |
| 28 | Earth work excavation and depositing on bank with in intial lead lift in hard gravelly soil foundation etc. complete for 20mm pVC pipe |
| 29 | Supply and delivery of 20mm dia PVC pipes and specials as per BIS 4985/2000 with ISI marking to site of works |
| 30 | Lowering and laying the 20mm dia PVC Pipes and specials to trench laying to proper grade and alognment |
| 31 | Refilling with excavated soil complying with standard specifications |
| 32 | 63*20mm saddle pvc |
| 33 | Brass ferrule 15mm |
| 34 | 15Lpm Brass flowcontrol valve |
| 35 | 20mm PVC FTA |
| 36 | 20mm pvc elbow |
| 37 | 20mm pvc MTA |
| 38 | 15mm Brass tap(LR) |
| 39 | 15mm Brass Ball Value (LR) |
| 40 | Cutting of 20mm PVC pipes |
| 41 | Labour charges for Drilling, cutting, Threading and Brass ferrule in distribution pipe |
| 42 | Precast RCC foundation post (0.15*0.15*1.2) and CC platform (0.60*0.60*0.1) |
| 43 | Provision Of Colorination Meter |
| 44 | Provision Of Water Meter |
| 45 | Provision for Name board |
| 46 | Name of Work :Providing FHTC to Karuthipalyam Habitation H/O Ichipalayam Panchayat |
| 47 | PROVIDING FHTC |
| 48 | Supply and delivery ofPVC rigid pipes for potable water supplywith ISI 4985 / 2000marking with necessary couplers (or) bell ended pipes as specified in ISI, the required quantity of solvent cement and having the following working pressure. The cost of pipes should include loading, freight, transit insurance, incidental charges, packing, taxes and transportation charges upto stack yard in good condition etc., complete (the cost excluding unloading from lorries at stack yard and stacking which will be paid separately) and as directed by the TWAD Board Officers. |
| 49 | 90 MM PVC 4KSC PIPPE |
| 50 | 75 MM PVC 4KSC PIPPE |
| 51 | Supply and delivery of the following PVC Specials suitable for PVC Pipes including loading, freight, unloading, stacking at Stockyard , insurance etc., complete as per IS 10124/1982 Part -II and as directed |
| 52 | 90mm PVC Bend |
| 53 | 90mm PVC End Tee |
| 54 | 90mm PVC End Cap |
| 55 | 75mm PVC Bend |
| 56 | 75mm PVC Equal Tee |
| 57 | 75mm PVC End Cap |
| 58 | 63mm GI Gate Valve |
| 59 | II.Civil Works |
| 60 | Earth work excavation and depositng on bank within an initial lead of 10 m and initial lift 0 to 2 min Hard stiff clay, stiff block cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size bouldersfor laying pipeline in respect of following size of pipe with standard trench width and required depth including shoring, struting, balling out water wherever necessary and all other incidental works such as barricading, providing danger lights, labour for watch and ward,as oer standard specifications andas directed by the TWAD Board officers |
| 61 | 90 MM PVC 4KSC PIPPE |
| 62 | Lowering PVC rigid pipes and specials to trench and laying to proper grade and alignment, jointing with PVC couplers with cement paste as per standard specifications and as directed by theTWAD Board Officers. |
| 63 | For depth upto 2m |
| 64 | 90 MM PVC 4KSC PIPPE |
| 65 | 75 MM PVC 4KSC PIPPE |
| 66 | Refilling with excavated earth (other than sand) in respect of following sizes of pipeswateredwell rammed and consolidated etc.complete complying with standard specification for filling the trenches after the pipes and specials are laid, jointed and tested and as directed by the TWAD Board Officers. |
| 67 | 90 MM PVC 4KSC PIPPE |
| 68 | 75 MM PVC 4KSC PIPPE |
| 69 | Road Relaying charges |
| 70 | Restoring the Cut CC .Roadby Paver block |
| 71 | B.T Cutting |
| 72 | FHTC DISTRIBUTION LINE |
| 73 | Earth work excavation and depositing on bank with in intial lead lift in hard gravelly soil foundation etc. complete for 20mm pVC pipe |
| 74 | Supply and delivery of 20mm dia PVC pipes and specials as per BIS 4985/2000 with ISI marking to site of works |
| 75 | Lowering and laying the 20mm dia PVC Pipes and specials to trench laying to proper grade and alognment |
| 76 | Refilling with excavated soil complying with standard specifications |
| 77 | 63*20mm saddle pvc |
| 78 | Brass ferrule 15mm |
| 79 | 15Lpm Brass flowcontrol valve |
| 80 | 20mm PVC FTA |
| 81 | 20mm pvc elbow |
| 82 | 20mm pvc MTA |
| 83 | 15mm Brass tap(LR) |
| 84 | 15mm Brass Ball Value (LR) |
| 85 | Cutting of 20mm PVC pipes |
| 86 | Labour charges for Drilling, cutting, Threading and Brass ferrule in distribution pipe |
| 87 | Precast RCC foundation post (0.15*0.15*1.2) and CC platform (0.60*0.60*0.1) |
| 88 | Provision Of Colorination Meter |
| 89 | Provision Of Water Meter |
| 90 | Provision for Name board |
| 91 | Name of Work :Providing FHTC to Panapalayam Habitation H/O Ichipalayam Panchayat |
| 92 | PROVIDING FHTC |
| 93 | Supply and delivery ofPVC rigid pipes for potable water supplywith ISI 4985 / 2000marking with necessary couplers (or) bell ended pipes as specified in ISI, the required quantity of solvent cement and having the following working pressure. The cost of pipes should include loading, freight, transit insurance, incidental charges, packing, taxes and transportation charges upto stack yard in good condition etc., complete (the cost excluding unloading from lorries at stack yard and stacking which will be paid separately) and as directed by the TWAD Board Officers. |
| 94 | 90 MM PVC 4KSC PIPPE |
| 95 | 75 MM PVC 4KSC PIPPE |
| 96 | Supply and delivery of the following PVC Specials suitable for PVC Pipes including loading, freight, unloading, stacking at Stockyard , insurance etc., complete as per IS 10124/1982 Part -II and as directed |
| 97 | 90mm PVC Bend |
| 98 | 90mm PVC End Tee |
| 99 | 90mm PVC End Cap |
| 100 | 75mm PVC Bend |
| 101 | 75mm PVC Equal Tee |
| 102 | 75mm PVC End Cap |
| 103 | 63mm GI Gate Valve |
| 104 | II.Civil Works |
| 105 | Earth work excavation and depositng on bank within an initial lead of 10 m and initial lift 0 to 2 min Hard stiff clay, stiff block cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size bouldersfor laying pipeline in respect of following size of pipe with standard trench width and required depth including shoring, struting, balling out water wherever necessary and all other incidental works such as barricading, providing danger lights, labour for watch and ward,as oer standard specifications andas directed by the TWAD Board officers |
| 106 | 90 MM PVC 4KSC PIPPE |
| 107 | Lowering PVC rigid pipes and specials to trench and laying to proper grade and alignment, jointing with PVC couplers with cement paste as per standard specifications and as directed by theTWAD Board Officers. |
| 108 | For depth upto 2m |
| 109 | 90 MM PVC 4KSC PIPPE |
| 110 | 75 MM PVC 4KSC PIPPE |
| 111 | Refilling with excavated earth (other than sand) in respect of following sizes of pipeswateredwell rammed and consolidated etc.complete complying with standard specification for filling the trenches after the pipes and specials are laid, jointed and tested and as directed by the TWAD Board Officers. |
| 112 | 90 MM PVC 4KSC PIPPE |
| 113 | 75 MM PVC 4KSC PIPPE |
| 114 | Road Relaying charges |
| 115 | Restoring the Cut CC .Roadby Paver block |
| 116 | B.T Cutting |
| 117 | FHTC DISTRIBUTION LINE |
| 118 | Earth work excavation and depositing on bank with in intial lead lift in hard gravelly soil foundation etc. complete for 20mm pVC pipe |
| 119 | Supply and delivery of 20mm dia PVC pipes and specials as per BIS 4985/2000 with ISI marking to site of works |
| 120 | Lowering and laying the 20mm dia PVC Pipes and specials to trench laying to proper grade and alognment |
| 121 | Refilling with excavated soil complying with standard specifications |
| 122 | 63*20mm saddle pvc |
| 123 | Brass ferrule 15mm |
| 124 | 15Lpm Brass flowcontrol valve |
| 125 | 20mm PVC FTA |
| 126 | 20mm pvc elbow |
| 127 | 20mm pvc MTA |
| 128 | 15mm Brass tap(LR) |
| 129 | 15mm Brass Ball Value (LR) |
| 130 | Cutting of 20mm PVC pipes |
| 131 | Labour charges for Drilling, cutting, Threading and Brass ferrule in distribution pipe |
| 132 | Precast RCC foundation post (0.15*0.15*1.2) and CC platform (0.60*0.60*0.1) |
| 133 | Provision Of Colorination Meter |
| 134 | Provision Of Water Meter |
| 135 | Provision for Name board |
| 136 | Name of Work :Providing FHTC to Vengamettupudur Habitation H/O Ichipalayam Panchayat |
| 137 | PROVIDING FHTC |
| 138 | Supply and delivery ofPVC rigid pipes for potable water supplywith ISI 4985 / 2000marking with necessary couplers (or) bell ended pipes as specified in ISI, the required quantity of solvent cement and having the following working pressure. The cost of pipes should include loading, freight, transit insurance, incidental charges, packing, taxes and transportation charges upto stack yard in good condition etc., complete (the cost excluding unloading from lorries at stack yard and stacking which will be paid separately) and as directed by the TWAD Board Officers. |
| 139 | 90 MM PVC 4KSC PIPPE |
| 140 | 75 MM PVC 4KSC PIPPE |
| 141 | Supply and delivery of the following PVC Specials suitable for PVC Pipes including loading, freight, unloading, stacking at Stockyard , insurance etc., complete as per IS 10124/1982 Part -II and as directed |
| 142 | 90mm PVC Bend |
| 143 | 90mm PVC End Tee |
| 144 | 90mm PVC End Cap |
| 145 | 75mm PVC Bend |
| 146 | 75mm PVC Equal Tee |
| 147 | 75mm PVC End Cap |
| 148 | 63mm GI Gate Valve |
| 149 | II.Civil Works |
| 150 | Earth work excavation and depositng on bank within an initial lead of 10 m and initial lift 0 to 2 min Hard stiff clay, stiff block cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size bouldersfor laying pipeline in respect of following size of pipe with standard trench width and required depth including shoring, struting, balling out water wherever necessary and all other incidental works such as barricading, providing danger lights, labour for watch and ward,as oer standard specifications andas directed by the TWAD Board officers |
| 151 | 90 MM PVC 4KSC PIPPE |
| 152 | Lowering PVC rigid pipes and specials to trench and laying to proper grade and alignment, jointing with PVC couplers with cement paste as per standard specifications and as directed by theTWAD Board Officers. |
| 153 | For depth upto 2m |
| 154 | 90 MM PVC 4KSC PIPPE |
| 155 | 75 MM PVC 4KSC PIPPE |
| 156 | Refilling with excavated earth (other than sand) in respect of following sizes of pipeswateredwell rammed and consolidated etc.complete complying with standard specification for filling the trenches after the pipes and specials are laid, jointed and tested and as directed by the TWAD Board Officers. |
| 157 | 90 MM PVC 4KSC PIPPE |
| 158 | 75 MM PVC 4KSC PIPPE |
| 159 | Road Relaying charges |
| 160 | Restoring the Cut CC .Roadby Paver block |
| 161 | B.T Cutting |
| 162 | FHTC DISTRIBUTION LINE |
| 163 | Earth work excavation and depositing on bank with in intial lead lift in hard gravelly soil foundation etc. complete for 20mm pVC pipe |
| 164 | Supply and delivery of 20mm dia PVC pipes and specials as per BIS 4985/2000 with ISI marking to site of works |
| 165 | Lowering and laying the 20mm dia PVC Pipes and specials to trench laying to proper grade and alognment |
| 166 | Refilling with excavated soil complying with standard specifications |
| 167 | 63*20mm saddle pvc |
| 168 | Brass ferrule 15mm |
| 169 | 15Lpm Brass flowcontrol valve |
| 170 | 20mm PVC FTA |
| 171 | 20mm pvc elbow |
| 172 | 20mm pvc MTA |
| 173 | 15mm Brass tap(LR) |
| 174 | 15mm Brass Ball Value (LR) |
| 175 | Cutting of 20mm PVC pipes |
| 176 | Labour charges for Drilling, cutting, Threading and Brass ferrule in distribution pipe |
| 177 | Precast RCC foundation post (0.15*0.15*1.2) and CC platform (0.60*0.60*0.1) |
| 178 | Provision Of Colorination Meter |
| 179 | Provision Of Water Meter |
| 180 | Provision for Name board |
| 181 | GST |
AI Tender Summary
Tender Timeline
Jul 14, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedJul 27, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJul 27, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender