| 1 | Excavation in trenches in hard dense soil n.exc 1.5 mtr wide & n.exc 1.5mtr in depth and n. exc. 10sqm on plan for laying pipe in trenches and getting out complete allas specified and directed. |
| 2 | Returning filling in trenches, spreading, levelling, watering and well ramming in layers n.exc 25cm in hard dense soil complete all as specified and directed. |
| 3 | Removing of surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above starting point complete all as specified and directed. |
| 4 | Taking out unserviceable/defective/damaged/blockage GI pipe 15 mm bore steel water tubing,sorting out serviceable pipe fitting for reuse and cleaning the pipe including fitting and removing away all unserviceable pipe from site, complete all as specified and as directed. (Note: Exacavation and earhwork shall be measured and paid for separately.) |
| 5 | All as per serialitem No. 4.00 here-in-before but of size 20mm bore-ditto-. |
| 6 | All as per serialitem No. 4.00 here-in-before but of size 25 mm bore-ditto-. |
| 7 | All as per serialitem No. 4.00 here-in-before but of size 40mm bore-ditto-. |
| 8 | All as per serialitem No. 4.00 here-in-before but of size 50mm bore-ditto-. |
| 9 | All as per serialitem No. 4.00 here-in-before but of size 80mm bore-ditto-. |
| 10 | All as per serialitem No. 4.00 here-in-before but of size 100mm bore-ditto-. |
| 11 | S&F GI tubing medium grade, ISI Marked conforming to IS 1239 Part-I 2004, 15mm bore with and including all fittings such as bends , elbows,tees, short length, socket, union, check nuts, nipples etc. fixed and laid in trenches/floor/under culvert/road crossing etc including testing complete all as specified and as directed. |
| 12 | All as per serialitem No. 11.00 here-in-before but of size 20mm bore-ditto-. |
| 13 | All as per serialitem No. 11.00 here-in-before but of size 25mm bore-ditto-. |
| 14 | All as per serialitem No. 11.00 here-in-before but of size 40mm bore-ditto-. |
| 15 | All as per serialitem No. 11.00here-in-before but of size 50mm bore-ditto-. |
| 16 | All as per serialitem No. 11.00here-in-before but of size 80mm bore-ditto-. |
| 17 | All as per serialitem No. 11.00here-in-before but of size 100mm bore-ditto-. |
| 18 | Supply & fixing vertically/ horizontally on wall & laying150mm bore MS pipe, thickness not less than 5.40mm,flanged ends, laid in trenches including taking out old unserviceable pipe complete all as specified and directed. |
| 19 | Taking out old unsv and S&F Bronze gate valve for 15mm bore pipe,with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, fixed as in repair complete all as specified and directed. |
| 20 | All as per serialitem No. 19.00 here-in-before but of size 20mm bore-ditto-. |
| 21 | All as per serialitem No. 19.00 here-in-before but of size 25mm bore-ditto-. |
| 22 | All as per serialitem No. 19.00 here-in-before but of size 40mm bore-ditto-. |
| 23 | All as per serialitem No. 19.00 here-in-before but of size 50mm bore-ditto-. |
| 24 | Taking out old unsv and S&F 15mm bore bib tap, cast copper alloywith crutch or butter fly handle, chromium plated, fancy type, screwed down(ISI marked) conforming to IS 8931: 1993,screwed for iron pipe or for brass ferrule fixed as in repair complete all as specified and directed. |
| 25 | Taking out old unsv and S&F 20mm bore bib tap, cast copper alloywith crutch or butter fly handle, chromium plated, fancy type, screwed down(ISI marked) conforming to IS 8931: 1993,screwed for iron pipe or for brass ferrule fixed as in repair complete all as specified and directed. |
| 26 | Taking out old unsv and Supplying, fixing and testing of cast iron Sluice valve PN1.6 as per IS-14846, body, dome, wedge-CI IS:210, rings-bronze IS:318, Spindal-SS IS:6603, Gland Packing greasy jute packing, fasteners-CS, Gasket- Natural rubber, nominal size DN-150 mm, both ends flanged in existing line,afterremoval of old unserviceablesluice valve without damagingtoexistingpipeline complete all as specified and directed by Engr-in-charge. Note : Suitable size flanges for existing pipe line, Joints and jointing materials shall be included under this item. |
| 27 | All as per serialitem No. 26.00 here-in-before but nominal size DN-100 mm-ditto-. |
| 28 | All as per serialitem No. 26.00 here-in-before but nominal size DN-80 mm-ditto-. |
| 29 | Taking out old unsv and S&F Water meter 150 mm nominal bore conforming to IS:2373-1981 having CI casing bronze body and SS/Alloy/Bronze gear having dial duly marked with litres or kilolitres in boldface, thread/flanged end type with provision of strainer out side the meter , fixed as in repair complete all as specified and as directed . |
| 30 | All as per serialitem No. 29.00 here-in-before but of size 100 mm bore-ditto-. |
| 31 | All as per serialitem No. 29.00 here-in-before but of size 80 mm bore-ditto-. |
| 32 | All as per serialitem No. 29.00 here-in-before but of size 50 mm bore-ditto-. |
| 33 | All as per serialitem No. 29.00 here-in-before but of size 40 mm bore-ditto-. |
| 34 | Construction ofbrick masonary pit of size 60 x 60 x 60cm internal size with MS sheet 3mm thick and angle iron frame of size 40x40x6mm duly paintedwith 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and shown in drawingNo. STD- 1258, sheet 1/1. (original date - 30.11.93 and revised date - 15.09.2000 ) Note : Drawing mentioned above has not been enclosed herewith, however the same can be seen in the office ofGE Kasauli. |
| 35 | Construction ofbrick masonary pit of size 90 x 90 x 90 cm internal size with MS sheet 3mm thick and angle iron frame of size 40x40x6mm duly paintedwith 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and shown in drawingNo. STD- 1258, sheet 1/1 (original date - 30.11.93 and revised date - 15.09.2000 ) Note : Drawing mentioned above has not been enclosed herewith, however the same can be seen in the office ofGE Kasauli. |
| 36 | Construction ofbrick masonary pit of size 120 x 120 x 120cm internal size with MS sheet 3mm thick and angle iron frame of size 40x40x6mm duly paintedwith 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and shown in drawingNo. STD- 1258, sheet 1/1. (original date - 30.11.93 and revised date - 15.09.2000 ) Note:- Drawing mentioned above has not been enclosed herewith, however the same can be seen in the office ofGE Shimla hills Kasauli. |
| 37 | Dismantling and taking out old flanged and drilled pipe line complete with all fittings and flanged joints,150mm dia, including necessary excavation ,returning and filling etc complete, removing unserviceable from site and transporting out of sitecomplete all as specified and directed by Engr-in-charge. |
| 38 | Supplying, laying, jointing and testing hot finished seamless carbon steel pipe not less than YST-240, grade B as per ASTM A 106, Sch 40, nominal sizeNPS-150 mm, outer dia 168.30 mm, with nominal wall thickness 7.1 mm and weight 28.22 Kg/ Rm, including short pieces as required at site, laid in trenches/over RCC pillars/across or under bridges/along hill side (up or down)/culverts/inside valve pits complete all as specified snd directed by Engr-in-charge. NOTE:- (i) Excavation Earth work, PCC, seamless pipe fittings, MS flanges & flanged joints shall measured and paid for separatly under relevant items.(ii) Work will be carried out in piecemeal loacations experienced based on break downsand weaker sections of existing rising main as per site requirement and as directed by Engineer-in-charge.(iii) Any other expenses including permision from state authorities are included under this item. |
| 39 | Supplying, laying, jointing and testing bends, suitable length, radius as specified and as per site requirement, made of hot finished seamless carbon steel pipe not less than YST-240, grade B as per ASTM A 106, Sch 40, nominal size NPS-150 mm, outer dia 168.30 mm, with nominal wall thickness 7.1 mm and weight 28.2 Kg/ Rm, including short pieces with flanged ends duly fabricated as required at site, laid in trenches/over RCC pillars/across or under bridges/along hill side (up or down)/culverts/inside valve pits complete all as specified snd directed by Engr-in-charge. NOTE:- As per item No - 38.00. |
| 40 | Supplying, laying, jointing and testing of Tees, suitable length and as per site requirement, made of hot finished seamless carbon steel pipe not less than YST-240, grade B as per ASTM A 106, Sch 40, nominal size NPS-150 mm, outer dia 168.30 mm, with nominal wall thickness 7.1 mm and weight 28.2 Kg/ Rm, including short pieces with flanged ends duly fabricated as required at site, laid in trenches/over RCC pillars/across or under bridges/along hill side (up or down)/culverts/inside valve pits complete all as specified and directed by Engr-in-charge.NOTE:- As per item No - 38.00. |
| 41 | Supply and fixing heavy duty MS flange of nominal size DN-150, duly painted with two coats of black japanpaint, for NPS-150 mm nominal size pipes, 36 mm thick, 345 mm outer dia,having 8 nos hole of size 33 mm drilled for M30 size bolts for jointing with existing pipes,duly welded with pipes/tees/ bends properly to both the plain ends complete all as specified and directed by Engr-in-charge. |
| 42 | Flanged joint for 150mm nominal size pipes comprising of one 3.0 mm steel reinforced compressed asbestos fibre gasket and 8 nos nuts, bolts of size M30 and 125 mm length and 2 nos washers 3 mm thick for each bolt to joint pipes/fittings/bends etc complete all as specified and directed by Engr-in-charge. |
| 43 | Supplying, fixing and testing of high pressure, heavy duty cast steel sluice valve, nominal size DN-150 mm, conforming to API 600, Class 600, suitable to hydrostatic test pressure for body 156 kg/sq cm & for seat 115 kg/sq cm, both ends flanged in existing line,afterremoval of old unserviceable gate valve without damagingtoexistingpipeline complete all as specified and directed by Engr-in-charge. Note : Suitable size MS flanges for existing pipe line, Joints and jointing materials shall be included under this item. |
| 44 | Supplying, fixing and testing of high pressure, heavy duty cast steel non return valve/ check valve, nominal size DN-150 mm, conforming to BS 1868, Class 600, suitable to hydrostatic test pressure for body 156 kg/sq cm & for seat 115 kg/sq cm, both ends flanged in existing line,afterremoval of old unserviceablenon return valve without damagingtoexistingpipeline complete all as specified and directed by Engr-in-charge. Note : Suitable size MS flanges for existing pipe line, Joints and jointing materials shall be included under this item. |
| 45 | Two coats of synthetic enameled paint (tint of paint as directed)over one coat of red oxide primer on surfaces over 10 cm width or girth including preparation of new surfaces on mild steel pipeincluding fittings, Gate valve and NRV etccomplete fromtank to pump set and from pump set to delivery gate valve in Pit chamber , and writing names/lettersusing white paint as directed at different locations of water supply installationat kasaulicomplete all as specified and directed by Engineer-in-charge. |
| 46 | Dismantling of defective/unsv150 mm nominal size pipe line and taking outfrom trencheswith necessary excavation work and carrying out the reapirwork at site or localwk shop forwelding work to repair defective portion of pipe line and providing leak proof jointing materialtoleaked/pierced portion and took back after repair to work site completeand relaying of repaired pipe line 150mm bore in trenches and jointing the same in trenches complete with new gasket, nut bolts and other jointing material includingtesting/commissioning the pipe line on full pressure complete all as specified and directed by Engr-in-charge. NOTE :- (i) MS flanges & flanged joints shall measured and paid for separatly under relevant items.(ii) Work will be carried out in piecemeal loacations experienced based on break downsand weaker sections of existing rising main as per site requirement and as directed by Engineer-in-charge. |
| 47 | Dismantling of defective/unsv100 mm nominal size pipe line and taking outfrom trencheswith necessary excavation work and carrying out the reapirwork at site or localwk shop forwelding work to repair defective portion of pipe line and providing leak proof jointing materialtoleaked/pierced portion and took back after repair to work site completeand relaying of repaired pipe line 100mm bore in trenches and jointing the same in trenches complete with new gasket, nut bolts and other jointing material includingtesting/commissioning the pipe line on full pressure complete all as specified and directed by Engr-in-charge. NOTE :- (i) MS flanges & flanged joints shall measured and paid for separatly under relevant items.(ii) Work will be carried out in piecemeal loacations experienced based on break downsand weaker sections of existing rising main as per site requirement and as directed by Engineer-in-charge. |
| 48 | PCC (1:3:6) type C2 using 40mm graded stone aggregate for anchorage blocks for pipe line/making good the cut portion of roads/paths/hard standings etc including necessary from work where required , to support the pipe line complete all as specified and as directed by Engineer-in-charge. |
| 49 | Cross arms bracings, support, clamps and back plates fabricated from structural steel section including nuts, bolts, washers etc, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint complete all as specified and directed by Engineer-in-charge. |
| 50 | Supply of calcium hypo chloride, 65%-70% chlorine content, high strength granular disinfectant for treatment of drinking water complete all as specified and qty as per requirement and as directed by Engr-in-Charge. |
| 51 | M & L for removing existing sludge from reservior & depositing the sludge upto 100 m distance & cleaning , scrapping down deposit from floor & wall , washing the walls/floor with bleaching powder in the resrvior of following capacity, includingwriting work with synthetic enamel paint on the wall (capacity , date of cleaning, date of next claening , location etc.) complete all as specified & directed. |
| 52 | 20 Lakhs gallon |
| 53 | 0.70 - 0.80Lakhs gallon |
| 54 | 0.4 - 0.6 Lakhs gallon |
| 55 | 0.20 - 0.30 Lakhs gallon |
| 56 | S&F MCCB 630 Amps 4 pole, 50 KA, 415 V, 50 Hz withthermal setting between 70% to 100%, adjustable type and connecting up in the existing panel locationincluding taking out existing unserviceable MCCBcompleteall as speciified and as directed by Engineer-in-charge. |
| 57 | S&F MCCB 400 Amps 4 pole, 35 KA, 415 V, 50 Hz withthermal setting between 70% to 100%, adjustable type and connecting up in the existing panel locationincluding taking out existing unserviceable MCCBcompleteall as speciified and as directed by Engineer-in-charge. |
| 58 | S&F MCCB 250 Amps 4 pole, 35 KA, 415 V, 50 Hz withthermal setting between 70% to 100%, adjustable type and connecting up in the existing panel locationincluding taking out existing unserviceable MCCBcompleteall as speciified and as directed by Engineer-in-charge. |
| 59 | Taking out old unsv and Supply, laying, jointing and testing replacement PVC insulated cable 1100 volt grade with multi stranded, single core copper 185 Sqmm,Grade As Per IS 7098 (Part 1) 1988 including making electrical connection for main panelto starter and starter to motor in pieces of suitable length as per site requirement duly fixed with suitable size of copper lugs/thimbles complete all as specified and as directed by Engr-in-charge. |
| 60 | S & F in repair/replacement Flanged rubber gasket of 3.0 mm thickness for 100/150mm nominal size pipes comprising of suitable holes for attachments, complete all as specified and directed by Engr-in-charge. |
| 61 | M & L electronic Water level indicator electrically operated digital type showing indication of water of under ground sump/ main service tank installed at various location of Dagshai station any capacity not below 2000 gallons including taking out existing mechanical water level indicator complete all as specified and directed. |
| 62 | Amount of credit of Rs. 157670.40 for retrived old material as mentioned in Schedule \"A\" section-II of tender document in pdf form, will be deducted offline while acceptence of tender. |