Supply Installation Testing Commissioning Of Electro Mechanical Equipments And Civil Works At Wss Wagar, Drygam, Gojra, Juhama And Mamath Nagradkah WSS WAGAR: Advt. Cost = 38.36 Lacs ( For Complete Electro Mechanical Component) 2 Supply, Installation, Testing & Commissioning of Open Well Pumping Units as per 14220 Stage.PUMP: -•Discharge = 8000GPH Head = 62mtrs(Rest Technical Specifications as per Annexure C 1) 3 Fabrication, providing and fitting of split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. 4 S/I/T/C of suitable size of GI nipple for pumping equipment at Sr. No.01. The nipple shall be threaded one side as per outlet of pump and weld with suitable size MS flange as per the size of the rising main/ pump delive 5 Providing and fitting of 16 Sq.mm 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipment. The cable connections terminal shall be fitted with copper thimbles of required size. Make: L&T/ABB/Havells or equivalent 6 Fabrication, Providing and fitting of Modular motor control panel of appropriate size fabricated out of 14 SWG sheet having re quired openings/vents and protection Class : IP-55 & fitted with accessories(Rest Technical Specifications as per Annexure C 1) 7 Providing, fitting, testing and commissioning of 50KVA voltage stabilizer(Rest Technical Specifications as per Annexure C 1) 8 Providing and Fitting of 3.5-Core, 50mm2XLPE, 1.1KV and 11KV grade Armoured Aluminum Cable of various sizes conforming toIS:7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. To be fitted from change over panel to modular panel. The job also includes P/F of Aluminumthimbles of various sizes as per size requirement including crimping and tapingMake: L&T/ABB/Havells or equivalent 9 Providing/supplying and fitting of 100mm dia G.I flanged Rising Main at site.The Pipe shall be hot dip Galvanized, class C confirming to IS 1239.The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. Flanges (as per IS 6392/1997 Table: 17) Thickness shall conform toIS6392Part1stTable-17.The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint. Welding Electrode DC Arc Welding using welding electrode having diameter not less than 4mm. Nuts and Bolts Nuts and Bolts (conforming to IS:1363 Part 1st) Rubber Insertion Gaskets Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints.Make: TATA/prakash/Surya/Jindal or equivalent 10 Fabrication / Providing / Fitting of Delivery Manifold with wash out arrangement fabricated out of (Class – C) GI pipe 100 mm and welded with 20 mm thickMS flange as per Table – 17 in two runs of welding . The job also includes cost on account of suitable size nuts, bolts and rubber packing in the flanged joints. The job also includes (12 mtrs) of GI 100 mm pipe arrangements forfitmentincluding bends, reducers etc for fitment of pumping equipment in the sump 11 Providing and fitting of Ductile Iron double flanged, Slanted seat swing check valve( NRV) 100mm as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approvedfordrinkingwater).The valve shall be compatibleforburiedapplicationsandshallbesafetoinstall in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve.Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos.M.Sflangesperfectly adaptable to the inbuilt flanges of the valve which shall be fittedwithRising main of the pumping unit atappropriatespotsaspersiterequirement.The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. Make: VAG/Kirloskar/AVK or equivalent 12 Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves 100 mm as per IS14846 for regulating the water supply outside the pumping units.The body and bonnent of the valve shall be of ductile iron, wedge with fully vulcanized EPDM rubber (Approved for drinking water) and NBR seal. The Gate/Sluice valveshallbecompatibleforburiedapplicationsandshallbe safe to install in both horizontal and vertical positions It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos.M.Sflangesperfectly adaptable to the inbuilt flanges of the valve which shallbe fittedwithrising main of the pumping unit atappropriatespotsaspersiterequirement.The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. Make: VAG/Kirloskar/AVK or equivalent 13 Fabrication, Providing and fitting of Y- junction having 1m length of each arm to be fabricated out of hot dip galvanized G.I, C-Class pipe. The job also includes Providing and welding of M.S flanges to the ends of each arm. The Thickness of flange shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint by dint of DC arc welding. The job further includes Providing and Fitting of nuts and bolts (conforming to IS:1363 Part 1st) and Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The size of the Y- junction is given below : Dia of the Pipe=100mm (execution of the item is conditional to site requirement) 14 Providing, fitting, testing and commissioning of ARV (Air Release valve) as per IS 14845 to be fitted to G.I rising Main. The ARV Shall have the following specifications: -Valve type - single chamber, single orifice.Nominal Dia=50mmEnd connection - flanged ends to IS 1538 Working temperature - 70oc to 550 cTest pressure - body / seat 2.5 x PNSealing ring - EPDMConstruction -ductile iron with stainless steel floats Coating - epoxy with corrosion resistance Besides the above works, The job also cost on account of P/F R.I gasket, nuts and bolts required for installation of ARV and arrangement of gas cutter/ welding set at site.Make: VAG/Kirloskar/AVK or equivalent 15 Fabrication of gantry mechanism by way of providing Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete Welded The job also includes painting of complete Structure in one coat of red oxide and 02 coats of enamel metal paint.Vertical Posts=ISMC 200 No. of vertical posts=02 Nos. Vertical channel section each post =02 Nos (seam welded face to face). vertical post bracing=ISMC 100 Sole / Matching plates=500x300x12 thickHeight of vertical posts=5 M size of vertical post concrete blocks=600x600x900 mm(Depth) Concrete grade=M20 welding Electrode= Overcord SS of Adore/ESAB/L&T/Advani Monorail Section=ISHB 250 length of monorail=5M Steel Detail :ISMC 200i 5Mx2x2=20 M @ 22.3kg/m = 446 kgIiISMC100 0.25Mx8x2x2=8 M@ 9.2kg/m = 73.60 kgiiiPlate 0.500x0.300x8 (12mmthk)=1.20 M²(12thk) = 112.80 kgivMonorail 5 M @ 51.4 kg/M ISHB250=257kgsv Bolts/Nuts(L.S)=30kgs Total=919.4 Kg say 920 Kg. 16 Providing, installation andtestingofmanualtypetriplespurgearchain pulley block having following features:Gears:- The hoist shall have precision machine case Hardened alloy steel gear mountedonbearingsandhousedina dustproofgearbox.Thelubrication of gears should be of high viscosity and temperature for longer life of gears.Load Chain:- The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation.Load chain wheel:- the load chainwellshouldbedoubleballbearing supportedandSpeciallydesigned,perfectlymachinedwheelproviding correct grip of load chain to makes the hoist most safe and reliable against any failure. The main specifications of C.P Block are given below :Make = Pull Lift/Indef or equivalentCapacity = 2 ton (P) No. Of load chain falls = 2 or above Min. Height of lift = 6 M 17 Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter including Providing / Installation of 12V, 180AH Automotive inverter Battery with trolley and cover. with 2-core 4 mm2 Cu ( 25 m) wiring as per site requirement along withotheraccessorieslikeSS-Combine(02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item. Make = Exide/Luminous or equivalent 18 Electrification of Pump House by way of P/F of:-Lighting points in 1.0 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 5 Amp. Switch, angle / button holder, 9 W LED lamps with necessary fixtures. – 08 jobsLighting points, bulk head type in 1.0 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 5 Amp. switch, angle / button holder, 9 W LED lampwith necessary fixtures – 06 jobsHeating points in 2.5 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 16 Amp. SS combine- 04 jobs5-pin socket points in 1.5 sq mm multi strandPVC insulated copper conductor to be laid / carried in PVC channel/conduit.- 04 jobs Indicator pointsin 1.0 sq mm multi strandPVC insulated copper conductor to be laid / carried in PVC channel/conduit – 04 jobsCeiling Fan with regulator switch, wiring in 1.5 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. and necessary fixtures. – 02 jobs Distribution Board SP & N ( Regal Grey ) with 01 No incoming and8 way outgoing, fitted with mini MCB “C” series 6A -04 No for lighting points and 2/3 pin socket points and fans, 10 A – 02 No for flood lights, 16 Amp – 02 No for heating points, 63 Amp MCB ( Mains ) – reputed make. The job also includes supply of 05KW sine wave voltage stabilizer single phase 90 – 270 V input for a constant output of 240 V. The fittings shall be modular type of reputed make 19 Illumination of Premises:Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mmwide,thickness3mmwith70 Microns Zinc coating having inside arrangement for providing of power connection along with following items.1) 3 Way Terminal Connector 20 Amp.2) 3 No MCB 8 Amp.The job includes fabrication, providing and fitting of three arm GI structure at the top having 120° angle between arms and each arm having 15° inclination with respect to horizontal plane. Each arm should be of 2’ length and size and shape appropriate as per requirement of the luminary.The job also includes providing and fitting of required length of flexible multi strand 2 mm copper wire from each terminal connector to each holding arm. The pole is mounted on 1:2:4 Cement concreting of size not less than 2’x2’x6” (cost of concreting not included in the job) using 04 No anchor bolts of required size not less than 7” in length. The complete job includes earthing inGI Electrode as per relevant IS Code 20 Providing, installation, testing and commissioning of area lighting120Watt LED (Street Light Type) on top of octagonal pole vide item No.36Having following specs:Input: 90-240 V 50 HzPower Factor: >0.9Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000Operating Temperature: -20°C to 60°CThe LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection up to IP-68.The LED is properly fitted on the arm of the pole and connected to the copperwire as provided in the high mast pole Make = Havells/L&T/Crompton or equivalent 21 Providing and installation of Junction Box with DP 32 A MCB to serve as Main switch for LED Lighting. The job includes making of electric connectionto the circuit. 22 Providing and carriage of Tool sets comprising of following items as mentioned below, for day today maintenance of Electro-Mechanical equipment’s installedat water supply scheme. The job shall include cost on account of carriage/transportation of tool set to the water supply scheme. The tools are to be provided in a strong tool box with key and lock mention below of reputed IS makei. Open end Spanner of Size (4/5 to 30/32) (01 complete set)ii. Ring Type Spanner of Size (4/5 to 30/32) (01 complete set)iii. Pliers, 9 inch: (01 No)iv. Nose Pliers 9 inch: (01No)v.Screw Driver 12 inch & 06 Inch:( 01 No Each)vi.Hammer with wooden handle, I Kg (01 No)vii.Pipe Wrench 12 inch: (01 No)viii Electric Multimeter =1No ix. Digital multimeter – 1No. x. Digital Clamp tester capable to measure up to 400A - 1 No. xi. Hack saw frame with hack saw blade – 01 no. Make = Taparia/Jhalani /Everest or equivalent 23 Supply, installation of 6 kg CO2 type fire extinguisher manufactured as per IS: 15683 of 2006 with IS mark and comply with DGMS (Approval). The co2 extinguisher should be suitable for class B & C fire and also for fire involving electrical equipment. The cylinder used for fire extinguisher shall be approved by petroleum and explosive safety organization (PESO) as per gas cylinder rules 2004 and as per IS: 7285 of 2004. The body should bemadeof seamless steel (manganese) confirming to IS: 7285 with IS mark and should be provided with squeeze grip nozzle and should be filled with co2 confirming to IS: 15222 of 2002 with certificate.The extinguisher shall be provided with manufactures test certificate and hydraulic test certificate by BIS from PESO. 24 Supply , installation , commissioning and creation of pole mounted, outdoor type 63kvacapacitylevel-2 Electric Sub Station (Rest Technical Specifications as per Annexure C 1) 25 Providing and fitting G.I Channel /Angle/ Flat of sizes including clamps ( for transformer bed, taping point , brackets of poles etc) 26 Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, ratedvoltage 11KV 200A complete as per IS specs(01 no. at existing tapping point and another at existing substation). 27 supply, Installation, Testing and commissioning of 11KV polymer fuses SetHorn Gap 3-phase 200 A suitable for vertical installation. 28 Supply, Installation, Testing and commissioning of Gapless Surge arrestorstation class, 10KA, 9KV, LA With polymer housing, Station Type. 29 Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepage distance 320mm 30 Supply, installation, erection of 9 mtrs long H.T pole of specifications ST-410 (sp-33) . The job further includes drilling of holes for installation of various accessories .wherever required the job further includes G.I wire earthing of pole as per REC standard. 31 P/F of Galvanized nuts, bolts of various sizes as per site requirement for fitment of electric substation,poles etc. 32 P/F Danger Plate with clamps 33 Providing and fixing G.I Barbed wire for anti-climbing/ anti-climbing devices 34 Providing and fitting of Galvanized stay set with 50 X 8 mm Stay Clamp , Guy insulator (2no.), Anchor plate (200X200X6mm) , nuts and bolts , 2 N0- turn buckle , 1.8 m long , 16 mm diameter solid G.I stay rod & 7/3.15 mm dia. G.Istranded wire complete. 35 Painting of poles Red oxide 18 no.s poles 36 Painting of poles Aluminum paint 18 poles 37 P/L of ACSR conductor of size 0.05 as per the relevant IS standard. 38 providing and fitting of Anchoring clamps comprising clamp body , plasticwedge, steel bill bracket , straps and buckles or nuts and bolts required for holding of 3 – Core , 35 Sq. mm H.T AB Cable. 39 P/F of 11 KV cable termination kit for connecting 35 Sq mm XLPE cable (ABCtype) with the existing HT line near tapping point and HT transformer 40 Providing andfittingofLTDistributionboxforH.TtransformerwithMCCBFor incomer and SFU for outgoing circuits. 41 P/I of earthing station for electric substation,LTpanelandstabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other itemsrequired thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards.Safe earthing electrode size : 80 mm dia , Length : 2000 mmBack fill compound : 30 kg 42 Providing, installation, Testing & commissioning of 415 ±10%V (output), 3 phase 40kva Air cooled Diesel Generator set as per IS 8528 (2018) and ISO 3046 (2002) for engine and IEC/IS 60034-1 for alternator suitably assembled and fitted in a pollution free acoustic enclosure / canopy of required size as per Ministry of Environment protection rule 1986 read with latest amendments. (Rest Technical Specifications as per Annexure C 1) 43 Earth work inn excavation by manual means in trenches for foundations, drains, pipes, cables etc (not exceeding 1.5m in width) and for shafts, wells, cesspits and the like not exceeding10 Sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5m, including getting out excavatedearth and disposal of surplus excavated earth asdirected. 44 Providing and laying of soling stone 45 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shattering. All works upto plinth level with 1:2:4 mix (1 cement, 2cores sand, 4 graded stone aggregate 20mm nominal size) 46 Centering and shattering including strutting, propping etc. and removal of from work for foundation, footings, base for columns 47 Providing and fitting of L.T, 3.5 core , 50mm Sq. cable to work up to 1.1 KV , XLPE insulated , galvanized steel strip armoured Almunium cable conforming to IS : 7098(part -1) 1988 With latest amendments to be fitted from D.G Set to Modular control panel . The job includes providing and fitting of suitable rating copper thimbles duly crimped and taped at conductor ends by hydraulic crimping tool. The job includes earth work in excavation whereverrequired for laying of cable underground. Make: L&T/ABB/Havells or equivalent 48 a) Providing of good quality bedding for night stay/Shift consisting of: -i) Mattress with warm cover size 6x3 (6Kg)- 02 No’sii) Quilt with warm cover size 5x8 (6Kg)- 02 No’siii) Pillows with covers - 02 No’siv) Single bed warm blankets with one sided Fur- 02 No’sThe filling material for mattress, quilt and pillow shall be of goodquality cottonb) The job also includes providing of pressure cooker 5ltr 02 No’s, Steel patella (utensil) 5ltrs 02 No’s, cooking heater 01 No., room heater 01 No., steel buckets 10 litre capacity 01 No., Plastic bucket 10 litre capacity with Mug 02 No’s each, steel glasses 06 No’s, steel Plates with large spoons and bowls 03 No’s each, Cup and Saucer set (01 No. Set) and, 5kg Gas cylinder with burner/ stove. The job also includes providing of thermo- cool 15’x12’ along with excel matting of 15’x12’ size. The job also includes providing of unbreakable Plastic Chair table set consisting of chairs 04 No’s, extra heavy Table 01 No. The job also includes providing of good quality safety Door locks (03 No’s) of Godrej, Link locks, 49 Providing of 2 KW heat convector for operators for winter season 50 Fabrication of 6’ x 6’ angle iron bed by way of providing and fitting of Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded 51 Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 no’s including cutting , fixing all complete including painting of the play sheet by one coat of primer and two coats of enamel paint 52 Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro- mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications:Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. The rubber mats shall be accepted with manufacturers test certificate. 53 WSS WAGAR: Advt. Cost = 15.56 Lacs ( For Complete Civil WorksComponent) 54 C.G.I SHED FOR HOUSING MECHANICAL EQUIPMENTS FOR WATER SUPPLY SCHEME WAGAR 55 Earthwork in excavation over areas exceeding 30cm in depth 1.50mtrs in width as well as 10sqm on plan mechanical means. 56 Providing and laying dry stone soiling 57 Providing and laying specified grade of cement concrete (1:4:8) mix. 58 Reinforced cement concrete in 1:1.5:3 mix. 59 Columns, Beams, Motor Base, 60 Slab 61 Reinforcement for RCC works including straightening, cutting, bending and placing in position hot rolled deformed steel bars. 62 Centering / shuttering including strutting, propping etc including removal of form work. 63 Raft 64 Beams 65 Columns 66 Slab 67 Edge 68 Providing/fixing of CGI roofing 69 Providing / fixing of rolling shatters 70 Providing / fixing hinges, handles, locking system 71 Carriage of construction materials from source to dumping / working site by Mechanical Transport. 72 a) Cement/steel from an average lead of 15kms 73 b) Sand/stone aggregate from an average lead of 25kms 74 c) Stone soling from an average lead of 30kms 75 RCC SUMP FOR WATER SUPPLY SCHEME WAGAR 76 Earth work in excavation by manual means over areas exceeding 30 cms & upto 5 m in depth 1.5m in width as well as 10 sqm. On plan, disposal of excavated earth upto 1 m, disposed earth to be levelled & neatly dressed 77 Providing & Laying ofstone soling (dully hand packed)including watering dressing and ramming with all carriages loading un-loading and stacking etc complete 78 Providing & laying in position cement concrete of specified grade excld.The cost of centring and shuttering all work upto plinth level(1:4:8) coarse sand 40mm nominal size crushed stone agg.) 79 P/L in position specified grade of reinforced cement cencrete (1:1.5:3)mix excld. the cost of centring, shuttering, finishing and reinforecement All work upto plinth level. With stone agg. 20mm nominal size 80 Raft 81 Walls 82 Slab 83 Centring and shuttering incld. Strutting, proping etc & removal of form work for Founadtions, footings, bases of columns for mass concrete 84 Raft 85 Walls 86 Slab 87 Edges 88 Reinforcement for RCC work incld straightning, cutting, bending, placing in position & binding all complete (Thermo-mechanically treated bars) 89 P/L 12-mm thick cement plaster in 1:3 90 Structural Steel work in single section fixed with connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved stee steel primer complete Lid+Ladder 91 Carriage of materails By Mech.Transport, from source to site of work 92 Sand/Stone Aggregates for an avg lead of 15 km 93 Cement & Steel for an avg lead of 15 km 94 Stone soling for an avg. lead of 15 km 95 WSS DREGYGAM: Advt. Cost = 38.86 Lacs ( For Complete Electro Mechanical Component) 96 Supply, Installation, Testing & Commissioning of Open Well Pumping Units as per 14220.PUMP: -Discharge= 6000GPHHead = 73mtrs(Rest Technical Specifications as per Annexure C 2) 97 Fabrication, providing and fitting of split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. 98 S/I/T/C of suitable size of GI nipple for pumping equipment at Sr. No.01. The nipple shall be threaded one side as per outlet of pump and weld with suitable size MS flange as per the size of the rising main/ pump delive 99 Providing and fitting of 16 Sq.mm 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipment. The cable connections terminal shall be fitted with copper thimbles of required size. Make: L&T/ABB/Havells or equivalent 100 Fabrication, Providing and fitting of Modular motor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories(Rest Technical Specifications as per Annexure C 2) 101 Providing, fitting, testing and commissioning of 50KVA voltage stabilizer as per specifications below:Capacity: 50KVAType of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step.Type of Regulator : Double plate type with electrolytic copper contacts. Input voltage : 150 volts.(3 phase)Output voltage : 400 ±10% volts.Frequency : 50 ±3 C/S.Windings : Electrolytic grade copper of adequate section, vacuum impregnated and Oven-dried.Insulation : Fiber glass insulations to tested parameters. Cooling: Naturally, Oil cooledTemp. Rise (Max): 30°C above ambient Mounting : On Uni-directional wheels. Correction rate : 30 volts per step Wave form distortion : virtually nil Duty cycle : 100% continuous.Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators. Core laminates : High grade, low eddy loss, grain oriented silicon steel laminations.Load : Three phase induction motor load. Load Amperes (continuous) Overload in 24-hours operation: 10% above continuous Ampere rating.The voltage stabilizer shall have T-oil levelindicatorgaugepreferablyglass type tube or otherwise visible to naked eye. The top of the container to have a display panel for housing 02 numbers Digital voltmeters (0-500V) along with 4-way selector switch and set of neon indicators for incoming and outgoing phases (06 No’s).Insulating media (T. Oil) of 11 KVA grade to be provided and filled up to top level, with dielectric strength of 5 KV at 4mm air gap. The T-Oil of specific grade should be provided in separate barrels and filled at site up to top level. The voltage Stabilizer shall be accepted with manufacturers dully stampedtest certificate and shall have name plate with specificationsMake : AE/Servocon or equivalent 102 Providing and Fitting of 3.5-Core, 50mm2XLPE, 1.1KV and 11KV grade Armoured Aluminum Cable of various sizes conforming toIS:7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. To be fitted from change over panel to modular panel. The job also includes P/F of Aluminumthimbles of various sizes as per size requirement including crimping and taping Make: L&T/ABB/Havells or equivalent 103 Providing/supplying and fitting of 100mm dia G.I flanged Rising Main at site.The Pipe shall be hot dip Galvanized, class C confirming to IS 1239.The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. Flanges (as per IS 6392/1997 Table: 17) Thickness shall conform toIS6392Part1stTable-17.The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint. Welding Electrode DC Arc Welding using welding electrode having diameter not less than 4mm. Nuts and Bolts Nuts and Bolts (conforming to IS:1363 Part 1st) Rubber Insertion Gaskets Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints.Make: TATA/prakash/Surya/Jindal or equivalent 104 Fabrication / Providing / Fitting of Delivery Manifold with wash out arrangement fabricated out of (Class – C) GI pipe 100 mm and welded with 18 mm thickMS flange as per Table – 5 in two runs of welding . The job also includes cost on account of suitable size nuts, bolts and rubber packing in the flanged joints. The job also includes (12 mtrs) of GI 80 mm pipe arrangements forfitmentincluding bends, reducers etc for fitment of pumping equipment in the sump 105 Providing and fitting of Ductile Iron double flanged, Slanted seat swing check valve( NRV) 100mm as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approvedfordrinkingwater).The valve shall be compatibleforburiedapplicationsandshallbesafetoinstall in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve.Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos.M.Sflangesperfectly adaptable to the inbuilt flanges of the valve which shall be fittedwithRising main of the pumping unit atappropriatespotsaspersiterequirement.The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. Make: VAG/Kirloskar/AVK or equivalent 106 Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves 100 mm as per IS14846 for regulating the water supply outside the pumping units.The body and bonnent of the valve shall be of ductile iron, wedge with fully vulcanized EPDM rubber (Approved for drinking water) and NBR seal. The Gate/Sluice valveshallbecompatibleforburiedapplicationsandshallbe safe to install in both horizontal and vertical positions It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc requiredfor the job is included in the scope of work. The job includes providing and fitting of 02 nos.M.Sflangesperfectly adaptable to the inbuilt flanges of the valve which shallbe fittedwithrising main of the pumping unit atappropriatespotsaspersiterequirement.The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. Make: VAG/Kirloskar/AVK or equivalent 107 Fabrication, Providing and fitting of Y- junction having 1m length of each arm to be fabricated out of hot dip galvanized G.I, C-Class pipe. The job also includes Providing and welding of M.S flanges to the ends of each arm. The Thickness of flange shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint by dint of DC arc welding. The job further includes Providing and Fitting of nuts and bolts (conforming to IS:1363 Part 1st) and Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The size of the Y- junction is given below : Dia of the Pipe=100mm (execution of the item is conditional to site requirement) 108 Providing, fitting, testing and commissioning of ARV (Air Release valve) as per IS 14845 to be fitted to G.I rising Main. The ARV Shall have the following specifications: -Valve type - single chamber, single orifice.End connection - flanged ends to IS 1538 Nominal Dia.-50mmWorking temperature - 70oc to 550 cTest pressure - body / seat 2.5 x PNSealing ring - EPDMConstruction -ductile iron with stainless steel floats Coating - epoxy with corrosion resistance Besides the above works, The job also cost on account of P/F R.I gasket, nuts and bolts required for installation of ARV and arrangement of gas cutter/ welding set at site.Make: VAG/Kirloskar/AVK or equivalent 109 Fabrication of gantry mechanism by way of providing Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete Welded The job also includes painting of complete Structure in one coat of red oxide and 02 coats of enamel metal paint.Vertical Posts=ISMC 200 No. of vertical posts=02 Nos. Vertical channel section each post =02 Nos (seam welded face to face). vertical post bracing=ISMC 100 Sole / Matching plates=500x300x12 thickHeight of vertical posts=5 M size of vertical post concrete blocks=600x600x900 mm(Depth) Concrete grade=M20 welding Electrode= Overcord SS of Adore/ESAB/L&T/Advani Monorail Section=ISHB 250 length of monorail=5M Steel Detail :ISMC 200i 5Mx2x2=20 M @ 22.3kg/m = 446 kgIiISMC100 0.25Mx8x2x2=8 M@ 9.2kg/m = 73.60 kgiiiPlate 0.500x0.300x8 (12mmthk)=1.20 M²(12thk) = 112.80 kgivMonorail 5 M @ 51.4 kg/M ISHB250=257kgsv Bolts/Nuts(L.S)=30kgs Total=919.4 Kg say 920 Kg. 110 Providing, installation andtestingofmanualtypetriplespurgearchain pulley block having following features:Gears:- The hoist shall have precision machine case Hardened alloy steel gear mountedonbearingsandhousedina dustproofgearbox.Thelubrication of gears should be of high viscosity and temperature for longer life of gears.Load Chain:- The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation.Load chain wheel:- the load chainwellshouldbedoubleballbearing supportedandSpeciallydesigned,perfectlymachinedwheelproviding correct grip of load chain to makes the hoist most safe and reliable against any failure. The main specifications of C.P Block are given below :Make = Pull Lift/Indef or equivalentCapacity = 2 ton (P) No. Of load chain falls = 2 or above Min. Height of lift = 6 M 111 Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter including Providing / Installation of 12V, 180AH Automotive inverter Battery with trolley and cover. with 2-core 4 mm2 Cu ( 25 m) wiring as per site requirement along withotheraccessorieslikeSS-Combine(02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item. Make = Exide/Luminous or equivalent 112 Electrification of Pump House by way of P/F of:-Lighting points in 1.0 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 5 Amp. Switch, angle / button holder, 9 W LED lamps with necessary fixtures. – 08 jobsLighting points, bulk head type in 1.0 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 5 Amp. switch, angle / button holder, 9 W LED lampwith necessary fixtures – 06 jobsHeating points in 2.5 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 16 Amp. SS combine- 04 jobs5-pin socket points in 1.5 sq mm multi strandPVC insulated copper conductor to be laid / carried in PVC channel/conduit.- 04 jobs Indicator pointsin 1.0 sq mm multi strandPVC insulated copper conductor to be laid / carried in PVC channel/conduit – 04 jobsCeiling Fan with regulator switch, wiring in 1.5 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. and necessary fixtures. – 02 jobs Distribution Board SP & N ( Regal Grey ) with 01 No incoming and8 way outgoing, fitted with mini MCB “C” series 6A -04 No for lighting points and 2/3 pin socket points and fans, 10 A – 02 No for flood lights, 16 Amp – 02 No for heating points, 63 Amp MCB ( Mains ) – reputed make. The job also includes supply of 05KW sine wave voltage stabilizer single phase 90 – 270 V input for a constant output of 240 V. The fittings shall be modular type of reputed make 113 Illumination of Premises:Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mmwide,thickness3mmwith70 Microns Zinc coating having inside arrangement for providing of power connection along with following items.1) 3 Way Terminal Connector 20 Amp.2) 3 No MCB 8 Amp.The job includes fabrication, providing and fitting of three arm GI structure at the top having 120° angle between arms and each arm having 15° inclination with respect to horizontal plane. Each arm should be of 2’ length and size and shape appropriate as per requirement of the luminary.The job also includes providing and fitting of required length of flexible multi strand 2 mm copper wire from each terminal connector to each holding arm. The pole is mounted on 1:2:4 Cement concreting of size not less than 2’x2’x6” (cost of concreting not included in the job) using 04 No anchor bolts of required size not less than 7” in length. The complete job includes earthing inGI Electrode as per relevant IS Code 114 Providing, installation, testing and commissioning of area lighting120Watt LED (Street Light Type) on top of octagonal pole having following specs:Input: 90-240 V 50 HzPower Factor: >0.9Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000Operating Temperature: -20°C to 60°CThe LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection up to IP-68.The LED is properly fitted on the arm of the pole and connected to the copperwire as provided in the high mast pole Make = Havells/L&T/Crompton or equivalent 115 Providing and installation of Junction Box with DP 32 A MCB to serve as Main switch for LED Lighting. The job includes making of electric connectionto the circuit. 116 Providing and carriage of Tool sets comprising of following items as mentioned below, for day today maintenance of Electro-Mechanical equipment’s installedat water supply scheme. The job shall include cost on account of carriage/transportation of tool set to the water supply scheme. The tools are to be provided in a strong tool box with key and lock mention below of reputed IS makei. Open end Spanner of Size (4/5 to 30/32) (01 complete set)ii. Ring Type Spanner of Size (4/5 to 30/32) (01 complete set)iii. Pliers, 9 inch: (01 No)iv. Nose Pliers 9 inch: (01No)v.Screw Driver 12 inch & 06 Inch:( 01 No Each)vi.Hammer with wooden handle, I Kg (01 No)vii.Pipe Wrench 12 inch: (01 No)viii Electric Multimeter =1No ix. Digital multimeter – 1No. x. Digital Clamp tester capable to measure up to 400A - 1 No. xi. Hack saw frame with hack saw blade – 01 no. Make = Taparia/Jhalani /Everest or equivalent 117 Supply, installation of 6 kg CO2 type fire extinguisher manufactured as per IS: 15683 of 2006 with IS mark and comply with DGMS (Approval). The co2 extinguisher should be suitable for class B & C fire and also for fire involving electrical equipment. The cylinder used for fire extinguisher shall be approved by petroleum and explosive safety organization (PESO) as per gas cylinder rules 2004 and as per IS: 7285 of 2004. The body should bemadeof seamless steel (manganese) confirming to IS: 7285 with IS mark and should be provided with squeeze grip nozzle and should be filled with co2 confirming to IS: 15222 of 2002 with certificate.The extinguisher shall be provided with manufactures test certificate and hydraulic test certificate by BIS from PESO. 118 Supply , installation , commissioning and creation of pole mounted, outdoor type 63kvacapacitylevel-2 Electric Sub Station as per the technical specifications given here under-Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments. Type: HT/LT TransformerType of cooling: ONAN. Operating conditions:Input =11000 voltsOutput =433 volts AC supply in 3- phase. Terminals:Input=3 No. HT bush rods with insulators, washer, nuts etc. Output=4 No. LT bush rods switch insulators, washers, nuts etc.Core: The core shall be of high permeability to reduce corelossesandthe strips shall be of suitable size and gauge.Transformer Coils:Suitable number ofHT and LT coils in each leg ofthe core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage, and all leads and lifts involved.The HT transformer shallbeofreputed makefroman ISO certifiedcompany as per relevant standards and a test certificate shall be provided before installation. The transformer shall also beprovidedwithbreatherfillwith silica jel crystals, conservator with oil level indicator,explosionvetand adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS: 1180 (Part 1) 2014 with latest amendments.NOTE: The scope of the work shall include obtaining of necessaryinspection/clearance certificate from the concerned department for all the required equipment. The testing and commissioning shall be completed onlyafter obtaining above certificate. 119 Providing and fitting G.I Channel /Angle/ Flat of sizes including clamps ( for transformer bed, taping point , brackets of poles etc) 120 Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, ratedvoltage 11KV 200A complete as per IS specs(01 no. at existing tapping point and another at existing substation). 121 supply, Installation, Testing and commissioning of 11KV polymer fuses SetHorn Gap 3-phase 200 A suitable for vertical installation. 122 Supply, Installation, Testing and commissioning of Gapless Surge arrestorstation class, 10KA, 9KV, LA With polymer housing, Station Type. 123 Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepage distance 320mm 124 Supply, installation, erection of 9 mtrs long H.T pole of specifications ST-410 (sp-33) . The job further includes drilling of holes for installation of various accessories .wherever required the job further includes G.I wire earthing of pole as per REC standard. 125 P/F of Galvanized nuts, bolts of various sizes as per site requirement for fitment of electric substation,poles etc. 126 P/F Danger Plate with clamps 127 Providing and fixing G.I Barbed wire for anti-climbing/ anti-climbing devices 128 Providing and fitting of Galvanized stay set with 50 X 8 mm Stay Clamp , Guy insulator (2no.), Anchor plate (200X200X6mm) , nuts and bolts , 2 N0- turn buckle , 1.8 m long , 16 mm diameter solid G.I stay rod & 7/3.15 mm dia. G.Istranded wire complete. 129 Painting of poles Red oxide 12 no.s poles 130 Painting of poles Aluminum paint 12 POLES 131 P/L of ACSR conductor of size 0.05 as per the relevant IS standard. 132 providing and fitting of Anchoring clamps comprising clamp body , plasticwedge, steel bill bracket , straps and buckles or nuts and bolts required for holding of 3 – Core , 35 Sq. mm H.T AB Cable. 133 P/F of 11 KV cable termination kit for connecting 35 Sq mm XLPE cable (ABCtype) with the existing HT line near tapping point and HT transformer 134 Providing andfittingofLTDistributionboxforH.TtransformerwithMCCBFor incomer and SFU for outgoing circuits. 135 P/I of earthing station for electric substation,LTpanelandstabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other itemsrequired thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards.Safe earthing electrode size : 80 mm dia , Length : 2000 mmBack fill compound : 30 kg 136 Providing, installation, Testing & commissioning of 415 ±10%V (output), 3 phase 50kvA water cooled Diesel Generator set(Rest Technical specifications as per Annexure C 2) 137 Earth work inn excavation by manual means in trenches for foundations, drains, pipes, cables etc (not exceeding 1.5m in width) and for shafts, wells, cesspits and the like not exceeding10 Sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5m, including getting out excavatedearth and disposal of surplus excavated earth asdirected. 138 Providing and laying of soling stone 139 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shattering. All works upto plinth level with 1:2:4 mix (1 cement, 2cores sand, 4 graded stone aggregate 20mm nominal size) 140 Centering and shattering including strutting, propping etc. and removal of from work for foundation, footings, base for columns 141 Providing and fitting of L.T, 3.5 core , 50mm Sq. capable to work up to 1.1 KV , XLPE insulated , galvanized steel strip armoured Aluminium cable conforming to IS : 7098(part -1) 1988 With latest amendments to be fitted from D.G Set to Modular control panel . The job includes providing and fitting of suitable rating copper thimbles duly crimped and taped at conductor ends by hydraulic crimping tool. The job includes earth work in excavation wherever required for laying of cable underground. Make: L&T/ABB/Havells or equivalent 142 a) Providing of good quality bedding for night stay/Shift consisting of: -i) Mattress with warm cover size 6x3 (6Kg)- 02 No’sii) Quilt with warm cover size 5x8 (6Kg)- 02 No’siii) Pillows with covers - 02 No’siv) Single bed warm blankets with one sided Fur- 02 No’sThe filling material for mattress, quilt and pillow shall be of goodquality cottonb) The job also includes providing of pressure cooker 5ltr 02 No’s, Steel patella (utensil) 5ltrs 02 No’s, cooking heater 01 No., room heater 01 No., steel buckets 10 litre capacity 01 No., Plastic bucket 10 litre capacity with Mug 02 No’s each, steel glasses 06 No’s, steel Plates with large spoons and bowls 03 No’s each, Cup and Saucer set (01 No. Set) and, 5kg Gas cylinder with burner/ stove. The job also includes providing of thermo- cool 15’x12’ along with excel matting of 15’x12’ size. The job also includes providing of unbreakable Plastic Chair table set consisting of chairs 04 No’s, extra heavy Table 01 No. The job also includes providing of good quality safety Door locks (03 No’s) of Godrej, Link locks, 143 Providing of 2 KW heat convector for operators for winter season 144 Fabrication of 6’ x 6’ angle iron bed by way of providing and fitting of Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded 145 Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 no’s including cutting , fixing all complete including painting of the play sheet by one coat of primer and two coats of enamel paint 146 Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro- mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications:Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. The rubber mats shall be accepted with manufacturers test certificate. 147 WSS DREGYGAM: Advt. Cost = 38.86 Lacs ( For Complete CIVIL Works Component) 148 CIVIL WORKS CHOWKIDARQUARTER CUM OPERATOR ROOM 149 Earth work in excavation by mannual means in trenchesfor foundation drains,pipes,cables&thelikenot exceeding10sqmon plan including disposal of excavated earth up to 50m and lift up to 1.5m, disposed soil to be neatly dressed 150 Providing&Layingof stonesoling(dullyhandpacked)including watering dressing and ramming with all carriages loading un-loadingand stacking etc complete 151 Providing&layinginpositioncementconcreteofspecifiedgrade excld. The cost of centringandshutteringall work upto plinthlevel(1:4:8 coarse sand 40 mm nominal size crushed stone agg.) 152 Providingandlayinginposition cementconcreteofspecifiedgrade excludingthecostofcenteringand shuttering.Allworkupto plinth levelin1:3:6(1cement:3coarsesand:6gradedstoneaggregate20mm nominal size). 153 Providing/Laying 50mm thick DPC in 1:2:4 mix exculding cost of formwork. 154 Supplyandfillinginplinthwithfinesandunderfloorsincludingwatering raming, consolidating and dressing complete. 155 P/L of cement concrete flooring 1:2:4 finished with a floating coat ofneat cement slurry and curing complete 50mm thick 156 Brickwork withcomonburntclay(Non-Modular)bricksofclass designation7.5infoundationinplinthincludingquarryincementmortar1:6 mix 157 Extra for Brick work in superstructure above plinth level upto floor Vlevel. 158 Providing/Layingof ReinforcedCementConcrete1:2:4excluding cost of form work and reinforcement max. size of graded stone agg.20mm (crushed) nominal in Lintels, beams and suspended floors. 159 Providing wood work in framesof doors,windows and CW wroughtframed and fixed in position with hold fast lugs in 1st class kail wood. 160 Providingandfixingpanelledorpanelledandglazedshuttersfor doorsandwindowsfixingwithbutthingesofrequiredsizewith necessary screw excluding panelling, butt hinges and necessary screws 35mm thick 1st class kail wood. 161 Extra for providing panelling or glazing for panelled/ glazed shutters. 162 Providing / fixing wire gauze shutters using galvinized M.S wire gauze of average width for aperture 1.4mm in both directions with wire dia 0.63mm in 1st class kail wood. 163 Providing and fixing glazed shutters 35mm thick for doors and windows. 164 Providing/fixing of flat iron M.S hold fasts. 165 20mm thick cement plaster on rough side of brick work in cementmotar 1:4 166 15mmthickcementplasteronfairsideofbrickworkincementmotar 1:4 167 Centering and shuttering including strutting, propping etc andremoval of same 168 Foundation /Plinth, 169 Beams , Lintels sides and Base 170 Suspended Floors,Slab Ceiling, Room, Bath, Kitchen and Passage, Sofit, 171 SteelreinforcementforRCCworkincludingstraightining,cutting,bending, placing in position and binding all complete. 172 ProvidingandapplyingPOP/wallputty2mmthickoverplastersurface to prepare the surface even and smooth. 173 Applying one coat of cement primer of approved brand andmanufacture for exterior surfaces. 174 Finishing walls with water proofingcement paint of approved brandand manufacture. 175 Distemperingwithoilbondwashabledistemperofapprovedbrandand manufacture. 176 Applying priming coat of ready mixed primer of approved brand andmanufacture on wood and wood based surface. 177 painting with synthetic enamel paint of approved brand andmanufacture on wood and wood based surface. 178 Providing / Fixing M.S grill of required pattern in frames of windowsand CW. 179 Providing / Fixing following building hardware items inlcuding screwsetc. Anodized Aluminum fittings. 180 100mm Handles 181 125mm Handles 182 200mm Tower Bolts 183 100mm Tower Bolts 184 250 x 16mm sliding door bolts 185 Making plinth protection 50mm thick of cement concrete 1:3:6 over74mm bed of dry brick blasts 40mm thick nominal size well ramed. 186 Filling available excavated earth back into trenches and consolidation. 187 Providing wood work in trusses, purlins, rafters etc. sawn and fixed inposition 1st class budloo or fir wood 188 Providing CGSsheet roofing with polynercoatedJorLhooks,bolts andnuts8mmdiameterewithbitumenandG.Ilimpetwashersor withG.ILimpetwashersfilledwithwhiteleadincludingcoatof approved steel primer and 2 coats of approved paint on overlappings of sheets complete. 0.63mm thick with zinc coating not less than 275grams / Sqm. 189 Providing rides or hipes of width 60cm overall width plain GS sheetsincluding G.I limpet washers filled with white lead. 190 Providing/fixing 20mm thick wooden planks sealing of Kail wood. 191 Providing/fixing 300 x 32mm 1st class kail wood eves boarding 192 ProvidingM.S.Lidwith50x 50x6mmAngleIronFrame(0.75x1.00m) and lid of 40 x 40 x 6mm frame and 30 x 6mm diagonals and 1mm M.S sheet. 193 Providing/fixing of WC Indian type Orissa pattern with P or S trap andlow level cistern 580 x 440mm size with foot rests complete 194 Providing / fixing Kitchen sink 195 Providing / fixing bewelled edge mirror. 196 Providing / fixing floor traps (LMR) 197 Providing/fixing bends with access door. 198 100mm Dia 199 75mm Dia 200 Providing / fixing Plain bends 201 100mm Dia 202 75mm Dia 203 Providing / fixing double equal junctions 100mm 204 Providing / fixing reducer 100 x 75mm (LMR) 205 Providing / fixing vent pipe 75mm 206 Providing / fixing cowel (LMR) 207 Providing / fixing gratting with Jali. 208 Providing / fixing PVC Waist Pipe flexible. 209 Providing / fixing holder bat clamps 210 100mm Dia 211 75mm Dia 212 Providing/fixing Ball Cock (LMR) 213 Providing/fixing PVC manhole covers with frame0.30 x 0.30 214 Providing / fixing Collars 215 100mm Dia 216 75mm Dia 217 Providing/fixing of Bib Taps C.P Brass 218 Providing/fillingjointswithspunyarncementslurryandcementmortar 1:2 mix 219 100mm dia 220 75mm Dia 221 Providing / fitting of GI pipes with GI fittings. 222 Concealed 15mm Dia 223 In trenches 20mm Dia 224 Providing / fixing of PVC connection pipe 45mm long. 225 Providing/Placingofterrace(atallfloorlevels)polyethylenewater storage tank ISI 12701 marked with cover and suitable locking arragements and making necessary holes for inlet outlet andoverflow pipes but without fittings and base support. 226 Random Rubble Stone masonry in 1:6 mix. 227 Random Rubble Stone masonry in walls laid dry. 228 Providing/fixing ceremic glazed tiles. (Floor/Wall) 229 Carriage ofmaterialsby Mechanical Transport inlcludingloading and unloading etc complete. 230 Stone Soling for an average lead of 15Kms. 231 40mm Stone Aggregate for an average lead of 30Kms. 232 Sand & 20mm aggregate for an average lead of 46Kms. 233 Cementfor an average lead of 20Kms. 234 Steel for an average lead of 20Kms. 235 Bricksfor an average lead of 120Kms. 236 Carriage ofmaterialsupto site of work by manual labourinlcludingloading and unloading etc complete for an average lead of 400mts. 237 Stone soling 238 40mm Stone Aggregate. 239 Sand/ 20mm stone aggregate 240 Cement 241 Steel 242 Bricks 243 CIVIL WORKS (CONSTRUCTION OF SUMP) 244 Earth work in excavation by manual means over areas exceeding 30 cms & upto 5 m in depth 1.5m in width as well as 10 sqm. On plan, disposal of excavated earth upto 1 m, disposed earth to be levelled & neatly dressed(all kinds of soils) 245 Providing & Laying of stone soling (dully hand packed)including watering dressing and ramming with all carriages loading un-loading and stackingetc complete 246 Providing & laying in position cement concrete of specified grade excld. The cost of centring and shuttering all work upto plinth level(1:4:8 coarse sand 40 mm nominal size crushed stone agg.) 247 P/L in position specified grade of reinforced cement cencrete (1:1.5:3) mix excld. the cost of centring, shuttering, finishing and reinforecement- All work upto plinth level. With stone agg. 20mm nominal size 248 Raft 249 Walls 250 Slab 251 Centring and shuttering incld. Strutting, proping etc & removal of form work for Founadtions, footings, bases of columns for mass concrete 252 Raft 253 Walls 254 Slab 255 Edges 256 Reinforcement for RCC work incld straightning, cutting, bending, placing in position & binding all complete (Thermo-mechanically treated bars) 257 P/L 12-mm thick cement plaster in 1:3 258 Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. 259 Structural Steel work in single section fixed with connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved stee steel primer completeLid+Ladder 260 Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered). Depth exceeding 1.5 m but not exceeding 3 m 261 Carriage of materials By Mech.Transport, from source to site of work 262 Sand/Stone Agg. for an avg lead of 15 km 263 Cement for an avg lead of 15 km 264 Stone soling for an avg. lead of 15 km 265 WSS GOJRA: Advt. Cost = 35.63 Lacs ( For Complete Electro Mechanical Component) 266 Supply, Installation, Testing & Commissioning of Open Well Pumping Units as per 14220 at Filter Water Stage.PUMP: -Discharge :-5000GPHHead :- 61 M(Rest Technical Specifications as per Annexure C 3) 267 Fabrication, providing and fitting of split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. 268 S/I/T/C of suitable size of GI nipple for pumping equipment at Sr. No.01. The nipple shall be threaded one side as per outlet of pump and weld with suitable size MS flange as per the size of the rising main/ pump delivery. 269 Providing and fitting of 16 Sq.mm 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipment. The cable connections terminal shall be fitted with copper thimbles of required size. Make: L&T/ABB/Havells or equivalent 270 Fabrication, Providing and fitting of Modular motor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories(Rest Technical Specifications as per Annexure C 3) 271 Providing, fitting, testing and commissioning of 50KVA voltage stabilizer (Rest Technical Specifications as per Annexure C 3) 272 Providing and Fitting of 3.5-Core, 50mm2XLPE, 1.1KV and 11KV grade Armoured Aluminum Cable of various sizes conforming toIS:7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. To be fitted from change over panel to modular panel. The job also includes P/F of Aluminumthimbles of various sizes as per size requirement including crimping and taping. Make: L&T/ABB/Havells or equivalent 273 Providing/supplying and fitting of 80mm dia G.I flanged Rising Main at site.The Pipe shall be hot dip Galvanized, class C confirming to IS 1239.The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. Flanges (as per IS 6392/1997 Table: 17) Thickness shall conform toIS6392Part1stTable-17.The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint. Welding Electrode DC Arc Welding using welding electrode having diameter not less than 4mm. Nuts and Bolts Nuts and Bolts (conforming to IS:1363 Part 1st) Rubber Insertion Gaskets Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. Make: TATA/prakash/Surya/Jindal or equivalent 274 Fabrication / Providing / Fitting of Delivery Manifold with wash out arrangement fabricated out of (Class – C) GI pipe 80 mm and welded with 18 mm thickMS flange as per Table – 17 in two runs of welding . The job also includes cost on account of suitable size nuts, bolts and rubber packing in the flanged joints. The job also includes (12 mtrs) of GI 80 mm pipe arrangements forfitmentincluding bends, reducers etc for fitment of pumping equipment in the sump 275 Providing and fitting of Ductile Iron double flanged, Slanted seat swing check valve( NRV) 80mm as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approvedfordrinkingwater).The valve shall be compatibleforburiedapplicationsandshallbesafetoinstall in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve.Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos.M.Sflangesperfectly adaptable to the inbuilt flanges of the valve which shall be fittedwithRising main of the pumping unit atappropriatespotsaspersiterequirement.The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. Make: VAG/Kirloskar/AVK or equivalent 276 Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves 80 mm as per IS14846 for regulating the water supply outside the pumping units.The body and bonnent of the valve shall be of ductile iron, wedge with fully vulcanized EPDM rubber (Approved for drinking water) and NBR seal. The Gate/Sluice valveshallbecompatibleforburiedapplicationsandshallbe safe to install in both horizontal and vertical positions It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos.M.Sflangesperfectly adaptable to the inbuilt flanges of the valve which shallbe fittedwithrising main of the pumping unit atappropriatespotsaspersiterequirement.The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. Make: VAG/Kirloskar/AVK or equivalent 277 Fabrication, Providing and fitting of Y- junction having 1m length of each arm to be fabricated out of hot dip galvanized G.I, C-Class pipe. The job also includes Providing and welding of M.S flanges to the ends of each arm. The Thickness of flange shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint by dint of DC arc welding. The job further includes Providing and Fitting of nuts and bolts (conforming to IS:1363 Part 1st) and Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The size of the Y- junction is given below : Dia of the Pipe=80mm (execution of the item is conditional to site requirement) 278 Providing, fitting, testing and commissioning of ARV (Air Release valve) as per IS 14845 to be fitted to G.I rising Main. The ARV Shall have the following specifications: -Valve type - single chamber, single orifice.Nominal Dia. 50mmEnd connection - flanged ends to IS 1538 Working temperature - 70oc to 550 cTest pressure - body / seat 2.5 x PNSealing ring - EPDMConstruction -ductile iron with stainless steel floats Coating - epoxy with corrosion resistance Besides the above works, The job also cost on account of P/F R.I gasket, nuts and bolts required for installation of ARV and arrangement of gas cutter/ welding set at site. Make: VAG/Kirloskar/AVK or equivalent 279 Fabrication of gantry mechanism by way of providing Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete Welded The job also includes painting of complete Structure in one coat of red oxide and 02 coats of enamel metal paint.Vertical Posts=ISMC 200 No. of vertical posts=02 Nos. Vertical channel section each post =02 Nos (seam welded face to face). vertical post bracing=ISMC 100 Sole / Matching plates=500x300x12 thickHeight of vertical posts=5 M size of vertical post concrete blocks=600x600x900 mm(Depth) Concrete grade=M20 welding Electrode= Overcord SS of Adore/ESAB/L&T/Advani Monorail Section=ISHB 250 length of monorail=5M Steel Detail :ISMC 200i 5Mx2x2=20 M @ 22.3kg/m = 446 kgIiISMC100 0.25Mx8x2x2=8 M@ 9.2kg/m = 73.60 kgiiiPlate 0.500x0.300x8 (12mmthk)=1.20 M²(12thk) = 112.80 kgivMonorail 5 M @ 51.4 kg/M ISHB250=257kgsv Bolts/Nuts(L.S)=30kgs Total=919.4 Kg say 920 Kg. 280 Providing, installation andtestingofmanualtypetriplespurgearchain pulley block having following features:Gears:- The hoist shall have precision machine case Hardened alloy steel gear mountedonbearingsandhousedina dustproofgearbox.Thelubrication of gears should be of high viscosity and temperature for longer life of gears.Load Chain:- The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation.Load chain wheel:- the load chainwellshouldbedoubleballbearing supportedandSpeciallydesigned,perfectlymachinedwheelproviding correct grip of load chain to makes the hoist most safe and reliable against any failure. The main specifications of C.P Block are given below :Make = Pull Lift/Indef or equivalent Capacity = 2 ton (P) No. Of load chain falls = 2 or above Min. Height of lift = 6 M 281 Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter including Providing / Installation of 12V, 180AH Automotive inverter Battery with trolley and cover. with 2-core 4 mm2 Cu ( 25 m) wiring as per site requirement along withotheraccessorieslikeSS-Combine(02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item.Make = Exide/Luminous or equivalent 282 Electrification of Pump House by way of P/F of:-Lighting points in 1.0 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 5 Amp. Switch, angle / button holder, 9 W LED lamps with necessary fixtures. – 08 jobsLighting points, bulk head type in 1.0 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 5 Amp. switch, angle / button holder, 9 W LED lampwith necessary fixtures – 06 jobsHeating points in 2.5 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 16 Amp. SS combine- 04 jobs5-pin socket points in 1.5 sq mm multi strandPVC insulated copper conductor to be laid / carried in PVC channel/conduit.- 04 jobs Indicator pointsin 1.0 sq mm multi strandPVC insulated copper conductor to be laid / carried in PVC channel/conduit – 04 jobsCeiling Fan with regulator switch, wiring in 1.5 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. and necessary fixtures. – 02 jobs Distribution Board SP & N ( Regal Grey ) with 01 No incoming and8 way outgoing, fitted with mini MCB “C” series 6A -04 No for lighting points and 2/3 pin socket points and fans, 10 A – 02 No for flood lights, 16 Amp – 02 No for heating points, 63 Amp MCB ( Mains ) – reputed make. The job also includes supply of 05KW sine wave voltage stabilizer single phase 90 – 270 V input for a constant output of 240 V. The fittings shall be modular type of reputed make 283 Illumination of Premises:Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mmwide,thickness3mmwith70 Microns Zinc coating having inside arrangement for providing of power connection along with following items.1) 3 Way Terminal Connector 20 Amp.2) 3 No MCB 8 Amp.The job includes fabrication, providing and fitting of three arm GI structure at the top having 120° angle between arms and each arm having 15° inclination with respect to horizontal plane. Each arm should be of 2’ length and size and shape appropriate as per requirement of the luminary.The job also includes providing and fitting of required length of flexible multi strand 2 mm copper wire from each terminal connector to each holding arm. The pole is mounted on 1:2:4 Cement concreting of size not less than 2’x2’x6” (cost of concreting not included in the job) using 04 No anchor bolts of required size not less than 7” in length. The complete job includes earthing inGI Electrode as per relevant IS Code 284 Providing, installation, testing and commissioning of area lighting120Watt LED (Street Light Type) on top of octagonal pole having following specifications:Input: 90-240 V, 50 HzPower Factor: >0.9Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000Operating Temperature: -20°C to 60°CThe LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection up to IP-68.The LED is properly fitted on the arm of the pole and connected to the copperwire as provided in the high mast poleMake = Havells/L&T/Crompton or equivalent 285 Providing and installation of Junction Box with DP 32 A MCB to serve as Main switch for LED Lighting. The job includes making of electric connectionto the circuit. 286 Providing and carriage of Tool sets comprising of following items as mentioned below, for day today maintenance of Electro-Mechanical equipment’s installed water supply scheme. The job shall include cost on account of carriage/transportation of tool set at water supply scheme. The tools are to be provided in a strong tool box with key and lock mention below of reputed IS makei. Open end Spanner of Size (4/5 to 30/32) (01 complete set)ii. Ring Type Spanner of Size (4/5 to 30/32) (01 complete set)III.Allen Key set black finish 02 setsiv.Combination Pliers, 9 inch: (01 No)v. Nose Pliers 9 inch: (01No)vi.Screw Driver 12 inch & 06 Inch:( 01 No Each)vii.Hammer with wooden handle, I Kg (01 No)viii.Pipe Wrench 12 inch: (01 No)ix. Digital multimeter 01 no.x.Digital Clamptester 400A- 01 noxi Hack saw frame with blade 01 no.xii S-16MXL,S-16 HXL Socket set (19 sockets +6 Accessories ) 01 no.Make = Taparia/Jhalani /Everest or equivalent 287 Supply, installation of 6 kg CO2 type fire extinguisher manufactured as per IS: 15683 of 2006 with IS mark and comply with DGMS (Approval). The co2 extinguisher should be suitable for class B & C fire and also for fire involving electrical equipment. The cylinder used for fire extinguisher shall be approved by petroleum and explosive safety organization (PESO) as per gas cylinder rules 2004 and as per IS: 7285 of 2004. The body should bemadeof seamless steel (manganese) confirming to IS: 7285 with IS mark and should be provided with squeeze grip nozzle and should be filled with co2 confirming to IS: 15222 of 2002 with certificate.The extinguisher shall be provided with manufactures test certificate and hydraulic test certificate by BIS from PESO. 288 26 Supply , installation , commissioning and creation of pole mounted, outdoor type 63kvacapacitylevel-2 Electric Sub Station as per the technical specifications given here under-Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments. Type: HT/LT TransformerType of cooling: ONAN. Operating conditions:Input =11000 voltsOutput =433 volts AC supply in 3- phase. Terminals:Input=3 No. HT bush rods with insulators, washer, nuts etc. Output=4 No. LT bush rods switch insulators, washers, nuts etc.Core: The core shall be of high permeability to reduce corelossesandthe strips shall be of suitable size and gauge.Transformer Coils:Suitable number ofHT and LT coils in each leg ofthe core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage, and all leads and lifts involved.The HT transformer shallbeofreputed makefroman ISO certifiedcompany as per relevant standards and a test certificate shall be provided before installation. The transformer shall also beprovidedwithbreatherfillwith silica jel crystals, conservator with oil level indicator,explosionvetand adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS: 1180 (Part 1) 2014 with latest amendments.NOTE: The scope of the work shall include obtaining of necessaryinspection/clearance certificate from the concerned department for all the required equipment. The testing and commissioning shall be completed only after obtaining above certificate. 289 Providing and fitting G.I Channel /Angle/ Flat of sizes including clamps ( for transformer bed, taping point , brackets of poles etc) 290 Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, ratedvoltage 11KV 200A complete as per IS specs(01 no. at existing tapping point and another at existing substation). 291 Supply, Installation, Testing and commissioning of 11KV polymer fuses SetHorn Gap 3-phase 200 A suitable for vertical installation. 292 Supply, Installation, Testing and commissioning of Gapless Surge arrestorstation class, 10KA, 9KV, LA With polymer housing, Station Type. 293 Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepage distance 320mm 294 Supply, installation, erection of 9 mtrs long H.T pole of specifications ST-410 (sp-33) . The job further includes drilling of holes for installation of various accessories .wherever required the job further includes G.I wire earthing of pole as per REC standard. 295 P/F of Galvanized nuts, bolts of various sizes as per site requirement for fitment of electric substation,poles etc. 296 P/F Danger Plate with clamps 297 Providing and fixing G.I Barbed wire for anti-climbing/ anti-climbing devices 298 Providing and fitting of Galvanized stay set with 50 X 8 mm Stay Clamp , Guy insulator (2no.), Anchor plate (200X200X6mm) , nuts and bolts , 2 N0- turn buckle , 1.8 m long , 16 mm diameter solid G.I stay rod & 7/3.15 mm dia. G.Istranded wire complete. 299 Painting of poles Red oxide 14 poles 300 Painting of poles Aluminum paint 14 poles 301 P/L of ACSR conductor of size 0.05 as per the relevant IS standard. 302 providing and fitting of Anchoring clamps comprising clamp body , plasticwedge, steel bill bracket , straps and buckles or nuts and bolts required for holding of 3 – Core , 35 Sq. mm H.T AB Cable. 303 P/F of 11 KV cable termination kit for connecting 35 Sq mm XLPE cable (ABCtype) with the existing HT line near tapping point and HT transformer 304 Providing andfittingofLTDistributionboxforH.TtransformerwithMCCBFor incomer and SFU for outgoing circuits. 305 P/I of earthing station for electric substation,LTpanelandstabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other itemsrequired thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards.Safe earthing electrode size : 80 mm dia , Length : 2000 mmBack fill compound : 30 kg 306 Providing, installation, Testing & commissioning of 415 ±10%V (output), 3 phase 30kva air cooled Diesel Generator set as per IS 8528 (2018) and ISO 3046 (2002) for engine and IEC/IS 60034-1 for alternator suitably assembled and fitted in a pollution free acoustic enclosure / canopy of required size (Rest Technical Specificatons as per Annexure C 3) 307 Earth work inn excavation by manual means in trenches for foundations, drains, pipes, cables etc (not exceeding 1.5m in width) and for shafts, wells, cesspits and the like not exceeding10 Sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5m, including getting out excavatedearth and disposal of surplus excavated earth asdirected. 308 Providing and laying of soling stone 309 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shattering. All works upto plinth level with 1:2:4 mix (1 cement, 2cores sand, 4 graded stone aggregate 20mm nominal size) 310 Centering and shattering including strutting, propping etc. and removal of from work for foundation, footings, base for columns 311 Providing and fitting of L.T, 3.5 core , 50mm Sq. capable to work up to 1.1 KV , XLPE insulated , galvanized steel strip armored Aluminum cable conforming to IS : 7098 (part -1) 1988 With latest amendments to be fitted from D.G Set to Modular control panel . The job includes providing and fitting of suitable rating copper thimbles duly crimped and taped at conductor ends by hydraulic crimping tool. The job includes earth work in excavation wherever required for laying of cable underground.Make: L&T/ABB/Havells or equivalent 312 a) Providing of good quality bedding for night stay/Shift consisting of: -i) Mattress with warm cover size 6x3 (6Kg)- 02 No’sii) Quilt with warm cover size 5x8 (6Kg)- 02 No’siii) Pillows with covers - 02 No’siv) Single bed warm blankets with one sided Fur- 02 No’sThe filling material for mattress, quilt and pillow shall be of goodquality cottonb) The job also includes providing of pressure cooker 5ltr 02 No’s, Steel patella (utensil) 5ltrs 02 No’s, cooking heater 01 No., room heater 01 No., steel buckets 10 litre capacity 01 No., Plastic bucket 10 litre capacity with Mug 02 No’s each, steel glasses 06 No’s, steel Plates with large spoons and bowls 03 No’s each, Cup and Saucer set (01 No. Set) and, 5kg Gas cylinder with burner/ stove. The job also includes providing of thermo- cool 15’x12’ along with excel matting of 15’x12’ size. The job also includes providing of unbreakable Plastic Chair table set consisting of chairs 04 No’s, extra heavy Table 01 No. The job also includes providing of good quality safety Door locks (03 No’s) of Godrej, Link locks, 313 Providing of 2 KW heat convector for operators for winter season 314 Fabrication of 6’ x 6’ angle iron bed by way of providing and fitting of Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded 315 Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 no’s including cutting , fixing all complete including painting of the play sheet by one coat of primer and two coats of enamel paint 316 Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro- mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications:Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. The rubber mats shall be accepted with manufacturers test certificate. 317 WSS GOJRA: Advt. Cost = 25.57 Lacs ( For Complete CIVIL Works Component) 318 CIVIL WORKS (CONSTRUCTION OF CWS & PUMP OPERATOR ROOM) 319 Earth work in excavation by manual means over areas exceeding 30 cms & upto 5m in depth 1.5m in width as well as 10 sqm. On plan, disposal of excavated earth upto 1 m, disposed earth to be levelled & neatly dressed( all kinds of soils) 320 Providing & Laying of stone soling (dully hand packed)including watering dressing and ramming with all carriages loading un-loading and stacking etc complete 321 Providing & laying in position cement concrete of specified grade excld. the cost of centring and shuttering all work upto plinth level(1:4:8 coarse sand 40mm nominal size crushed stone agg.) 322 P/L in position specified grade of reinforced cement cencrete excld. The cost of centring, shuttering, finishing and reinforecement-All work upto plinth level. 1:2:4 stone agg. 20mm nominal size 323 P/L in position specified grade of cement cencrete (1:3:6)excld. The cost of centring, shuttering, finishing and reinforecement-All work upto plinth level stone agg. 20mm nominal size 324 Providing & laying damp-proof Course 40 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone agg 12.5 mm nominal size) and curing complete 325 Brickwork in common burnt clay FPS bricks of class designed 75 in foundation in 1:4 mix 326 Extra for brick work in superstructure above plinth level upto floor V level. (By manual means) 327 P/L of Reinforced cement concrete 1:1.5:3 mix with 20-mm nominal size aggregates including curing but excluding cost of shuttering 328 Providing and fixing of pannalled wrought framed chowkats in wood work of 2nd class Deodar wood 329 Providing and fixing of pannalled/pannelled or glazed shutters 35-mm thick of 2nd class deodar wood including 4.0 mm thick glasss panes 330 Providing and fixing 35mm thick wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as perdirection of Engineer-in-charge 2nd class deodar wood 331 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. 332 Providing/fixing of hinges of sizes, handles, haldarwazs, latches incl. screws of sorts all complete job. 333 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutter 80x1.20 mm M.S. laths with 1.20 mm thick top cover 334 Shutter 335 Ball Bearing 336 Reinforcement for RCC work incld straightning, cutting, bending, placing in position & binding all complete (Thermo-mechanically treated bars) 337 Centering and shuttering incld. Strutting, proping etc & removal of form work for Founadtions, footings, bases of columns for mass concrete 338 Raft Step-1 , Step-2 Ramp 339 Lintel, V Beam , Shutter Beam 340 Slab 341 Edges 342 P/L 12-mm thick cement plaster in 1:4 343 Providing and fixing of sanitary items i.e Indian type WC, Beb Cock, 15-mm dia G.I Pipe with fittings, PVC waste Pipes, Sink to kitchen, 500 ltr PVC Tank etc 344 Provision for Construction of septic tank in brick masonary including connecting of PVC waste pipes 345 Provision for construction of soakage pit including excavation, dry stone masonary and slab etc complete job (Ready made RCC Rings to be used) 346 Providing and fixing Ist quality ceramic glazed tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 347 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 348 Applying priming coat With ready mixed pink or grey primer of approved brandand manufacture on wood work (hard and soft wood) 349 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an even shade two or more coat icluding priming coat (walls interior and exterior and wood work) 350 Providing and fitting of electrification to the operator Quarter 351 Steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position amd applying a priming coat of approved steel primer using structural steel 352 Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gram/m2 353 OP. Qtr 25 x 28 = 700 Sft @ 2.5 354 Eves boardings 355 Ridges or hips of width 60cm overall width 0.63 mm thick 356 Carriage of materails By Mech.Transport, from source to site of work 357 Sand andStone agg. for an avg lead of 15 km 358 Cement from Div. Store Awantipora for an avg lead of15 km 359 Bricks for an avg. lead of 26 km 360 Stone soling for an avg. lead of 15 km 361 WSS JUHAMA NEW: Advt. Cost = 39.00 Lacs( For Complete Electro Mechanical Component) 362 Supply, Installation, Testing & Commissioning of Open Well Pumping Units as per 14220 at Filter Water Stage.PUMP: -•Discharge: 5000GPHHead:78Mtrs(Rest Technical Specifications as per Annexure C 4) 363 Fabrication, providing and fitting of split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. 364 S/I/T/C of suitable size of GI nipple for pumping equipment at Sr. No.01. The nipple shall be threaded one side as per outlet of pump and weld with suitable size MS flange as per the size of the rising main/ pump delive 365 Providing and fitting of 16 Sq.mm 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipment. The cable connections terminal shall be fitted with copper thimbles of required size. Make: L&T/ABB/Havells or equivalent 366 Fabrication, Providing and fitting of Modular motor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories (Rest Technical Specifications as per Annexure C 4) 367 Providing, fitting, testing and commissioning of 50KVA voltage stabilizer (Rest Technical Specifications as per Annexure C 4) 368 Providing and Fitting of 3.5-Core, 50mm2 XLPE, 1.1KV and 11KV grade Armoured Aluminum Cable of various sizes conforming toIS:7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. To be fitted from change over panel to modular panel. The job also includes P/F of Aluminumthimbles of various sizes as per size requirement including crimping and taping Make: L&T/ABB/Havells or equivalent 369 Providing/supplying and fitting of 80mm dia G.I flanged Rising Main at site.The Pipe shall be hot dip Galvanized, class C confirming to IS 1239.The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. Flanges (as per IS 6392/1997 Table: 17) Thickness shall conform toIS6392Part1stTable-17.The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint. Welding Electrode DC Arc Welding using welding electrode having diameter not less than 4mm. Nuts and Bolts Nuts and Bolts (conforming to IS:1363 Part 1st) Rubber Insertion Gaskets Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints.Make: TATA/prakash/Surya/Jindal or equivalent 370 Fabrication / Providing / Fitting of Delivery Manifold with wash out arrangement fabricated out of (Class – C) GI pipe 80 mm and welded with 18 mm thickMS flange as per Table – 17 in two runs of welding . The job also includes cost on account of suitable size nuts, bolts and rubber packing in the flanged joints. The job also includes (12 mtrs) of GI 80 mm pipe arrangements forfitmentincluding bends, reducers etc for fitment of pumping equipment in the sump 371 Providing and fitting of Ductile Iron double flanged, Slanted seat swing check valve( NRV) 80mm as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approvedfordrinkingwater).The valve shall be compatibleforburiedapplicationsandshallbesafetoinstall in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve.Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos.M.Sflangesperfectly adaptable to the inbuilt flanges of the valve which shall be fittedwithRising main of the pumping unit atappropriatespotsaspersiterequirement.The job includes the cost on account of P/F of nuts, bolts and gasket required for the job.Make: VAG/Kirloskar/AVK or equivalent 372 Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves 80 mm as per IS14846 for regulating the water supply outside the pumping units.The body and bonnent of the valve shall be of ductile iron, wedge with fully vulcanized EPDM rubber (Approved for drinking water) and NBR seal. The Gate/Sluice valveshallbecompatibleforburiedapplicationsandshallbe safe to install in both horizontal and vertical positions It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos.M.Sflangesperfectly adaptable to the inbuilt flanges of the valve which shallbe fittedwithrising main of the pumping unit atappropriatespotsaspersiterequirement.The job includes the cost on account of P/F of nuts, bolts and gasket required for the job.Make: VAG/Kirloskar/AVK or equivalent 373 Fabrication, Providing and fitting of Y- junction having 1m length of each arm to be fabricated out of hot dip galvanized G.I, C-Class pipe. The job also includes Providing and welding of M.S flanges to the ends of each arm. The Thickness of flange shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint by dint of DC arc welding. The job further includes Providing and Fitting of nuts and bolts (conforming to IS:1363 Part 1st) and Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The size of the Y- junction is given below : Dia of the Pipe=80mm (execution of the item is conditional to site requirement) 374 Providing, fitting, testing and commissioning of ARV (Air Release valve) as per IS 14845 to be fitted to G.I rising Main. The ARV Shall have the following specifications: -Valve type - single chamber, single orifice.Nominal dia=50mmEnd connection - flanged ends to IS 1538 Working temperature - 70oc to 550 cTest pressure - body / seat 2.5 x PNSealing ring - EPDMConstruction -ductile iron with stainless steel floats Coating - epoxy with corrosion resistance Besides the above works, The job also cost on account of P/F R.I gasket, nuts and bolts required for installation of ARV and arrangement of gas cutter/ welding set at site. Make: VAG/Kirloskar/AVK or equivalent 375 Fabrication of gantry mechanism by way of providing Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete Welded The job also includes painting of complete Structure in one coat of red oxide and 02 coats of enamel metal paint.Vertical Posts=ISMC 200 No. of vertical posts=02 Nos. Vertical channel section each post =02 Nos (seam welded face to face). vertical post bracing=ISMC 100 Sole / Matching plates=500x300x12 thickHeight of vertical posts=5 M size of vertical post concrete blocks=600x600x900 mm(Depth) Concrete grade=M20 welding Electrode= Overcord SS of Adore/ESAB/L&T/Advani Monorail Section=ISHB 250 length of monorail=5M Steel Detail :ISMC 200i 5Mx2x2=20 M @ 22.3kg/m = 446 kgIiISMC100 0.25Mx8x2x2=8 M@ 9.2kg/m = 73.60 kgiiiPlate 0.500x0.300x8 (12mmthk)=1.20 M²(12thk) = 112.80 kgivMonorail 5 M @ 51.4 kg/M ISHB250=257kgsv Bolts/Nuts(L.S)=30kgs Total=919.4 Kg say 920 Kg. 376 Providing, installation andtestingofmanualtypetriplespurgearchain pulley block having following features:Gears:- The hoist shall have precision machine case Hardened alloy steel gear mountedonbearingsandhousedina dustproofgearbox.Thelubrication of gears should be of high viscosity and temperature for longer life of gears.Load Chain:- The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation.Load chain wheel:- the load chainwellshouldbedoubleballbearing supportedandSpeciallydesigned,perfectlymachinedwheelproviding correct grip of load chain to makes the hoist most safe and reliable against any failure. The main specifications of C.P Block are given below :Make = Pull Lift/Indef or equivalentCapacity = 2 ton (P) No. Of load chain falls = 2 or above Min. Height of lift = 6 M 377 Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter including Providing / Installation of 12V, 180AH Automotive inverter Battery with trolley and cover. with 2-core 4 mm2 Cu ( 25 m) wiring as per site requirement along withotheraccessorieslikeSS-Combine(02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item. Make = Exide/Luminous or equivalent 378 Electrification of Pump House by way of P/F of:-Lighting points in 1.0 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 5 Amp. Switch, angle / button holder, 9 W LED lamps with necessary fixtures. – 08 jobsLighting points, bulk head type in 1.0 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 5 Amp. switch, angle / button holder, 9 W LED lampwith necessary fixtures – 06 jobsHeating points in 2.5 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 16 Amp. SS combine- 04 jobs5-pin socket points in 1.5 sq mm multi strandPVC insulated copper conductor to be laid / carried in PVC channel/conduit.- 04 jobs Indicator pointsin 1.0 sq mm multi strandPVC insulated copper conductor to be laid / carried in PVC channel/conduit – 04 jobsCeiling Fan with regulator switch, wiring in 1.5 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. and necessary fixtures. – 02 jobs Distribution Board SP & N ( Regal Grey ) with 01 No incoming and8 way outgoing, fitted with mini MCB “C” series 6A -04 No for lighting points and 2/3 pin socket points and fans, 10 A – 02 No for flood lights, 16 Amp – 02 No for heating points, 63 Amp MCB ( Mains ) – reputed make. The job also includes supply of 05KW sine wave voltage stabilizer single phase 90 – 270 V input for a constant output of 240 V. The fittings shall be modular type of reputed make 379 Illumination of Premises:Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mmwide,thickness3mmwith70 Microns Zinc coating having inside arrangement for providing of power connection along with following items.1) 3 Way Terminal Connector 20 Amp.2) 3 No MCB 8 Amp.The job includes fabrication, providing and fitting of three arm GI structure at the top having 120° angle between arms and each arm having 15° inclination with respect to horizontal plane. Each arm should be of 2’ length and size and shape appropriate as per requirement of the luminary.The job also includes providing and fitting of required length of flexible multi strand 2 mm copper wire from each terminal connector to each holding arm. The pole is mounted on 1:2:4 Cement concreting of size not less than 2’x2’x6” (cost of concreting not included in the job) using 04 No anchor bolts of required size not less than 7” in length. The complete job includes earthing inGI Electrode as per relevant IS Code 380 Providing, installation, testing and commissioning of area lighting120Watt LED (Street Light Type) on top of octagonal pole vide item No.36Having following specs:Input: 90-240 V 50 HzPower Factor: >0.9Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000Operating Temperature: -20°C to 60°CThe LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection up to IP-68.The LED is properly fitted on the arm of the pole and connected to the copperwire as provided in the high mast poleMake = Havells/L&T/Crompton or equivalent 381 Providing and installation of Junction Box with DP 32 A MCB to serve as Main switch for LED Lighting. The job includes making of electric connectionto the circuit. 382 Providing and carriage of Tool sets comprising of following items as mentioned below, for day today maintenance of Electro-Mechanical equipment’s installedat water supply scheme. The job shall include cost on account of carriage/transportation of tool set to thewater supply scheme. The tools are to be provided in a strong tool box with key and lock mention below of reputed IS makei. Open end Spanner of Size (4/5 to 30/32) (01 complete set)ii. Ring Type Spanner of Size (4/5 to 30/32) (01 complete set)iii. Pliers, 9 inch: (01 No)iv. Nose Pliers 9 inch: (01No)v.Screw Driver 12 inch & 06 Inch:( 01 No Each)vi.Hammer with wooden handle, I Kg (01 No)vii.Pipe Wrench 12 inch: (01 No)viii Electric Multimeter =1No ix. Digital multimeter – 1No. x. Digital Clamp tester capable to measure up to 400A - 1 No. xi. Hack saw frame with hack saw blade – 01 no. Make = Taparia/Jhalani /Everest or equivalent 383 Supply, installation of 6 kg CO2 type fire extinguisher manufactured as per IS: 15683 of 2006 with IS mark and comply with DGMS (Approval). The co2 extinguisher should be suitable for class B & C fire and also for fire involving electrical equipment. The cylinder used for fire extinguisher shall be approved by petroleum and explosive safety organization (PESO) as per gas cylinder rules 2004 and as per IS: 7285 of 2004. The body should bemadeof seamless steel (manganese) confirming to IS: 7285 with IS mark and should be provided with squeeze grip nozzle and should be filled with co2 confirming to IS: 15222 of 2002 with certificate.The extinguisher shall be provided with manufactures test certificate and hydraulic test certificate by BIS from PESO. 384 Supply , installation , commissioning and creation of pole mounted, outdoor type 63kvacapacitylevel-2 Electric Sub Station as per the technical specifications given here under-Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments. Type: HT/LT TransformerType of cooling: ONAN. Operating conditions:Input =11000 voltsOutput =433 volts AC supply in 3- phase. Terminals:Input=3 No. HT bush rods with insulators, washer, nuts etc. Output=4 No. LT bush rods switch insulators, washers, nuts etc.Core: The core shall be of high permeability to reduce corelossesandthe strips shall be of suitable size and gauge.Transformer Coils:Suitable number ofHT and LT coils in each leg ofthe core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage, and all leads and lifts involved.The HT transformer shallbeofreputed makefroman ISO certifiedcompany as per relevant standards and a test certificate shall be provided before installation. The transformer shall also beprovidedwithbreatherfillwith silica jel crystals, conservator with oil level indicator,explosionvetand adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS: 1180 (Part 1) 2014 with latest amendments.NOTE: The scope of the work shall include obtaining of necessaryinspection/clearance certificate from the concerned department for all the required equipment. The testing and commissioning shall be completed only after obtaining above certificate. 385 Providing and fitting G.I Channel /Angle/ Flat of sizes including clamps ( for transformer bed, taping point , brackets of poles etc) 386 Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, ratedvoltage 11KV 200A complete as per IS specs(01 no. at existing tapping point and another at existing substation). 387 supply, Installation, Testing and commissioning of 11KV polymer fuses SetHorn Gap 3-phase 200 A suitable for vertical installation. 388 Supply, Installation, Testing and commissioning of Gapless Surge arrestorstation class, 10KA, 9KV, LA With polymer housing, Station Type. 389 Supply and fitting of 11 KV polymeric composite pin/discinsulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepage distance 320mm 390 Supply, installation, erection of 9 mtrs long H.T pole of specifications ST-410 (sp-33) . The job further includes drilling of holes for installation of various accessories .wherever required the job further includes G.I wire earthing of pole as per REC standard. 391 P/F of Galvanized nuts, bolts of various sizes as per site requirement for fitment of electric substation,poles etc. 392 P/F Danger Plate with clamps 393 Providing and fixing G.I Barbed wire for anti-climbing/ anti-climbing devices 394 Providing and fitting of Galvanized stay set with 50 X 8 mm Stay Clamp , Guy insulator (2no.), Anchor plate (200X200X6mm) , nuts and bolts , 2 N0- turn buckle , 1.8 m long , 16 mm diameter solid G.I stay rod & 7/3.15 mm dia. G.Istranded wire complete. 395 Painting of poles Red oxide 10 no.s poles 396 Painting of poles Aluminum paint 10 poles 397 P/L of ACSR conductor of size 0.05 as per the relevant IS standard. 398 providing and fitting of Anchoring clamps comprising clamp body , plasticwedge, steel bill bracket , straps and buckles or nuts and bolts required for holding of 3 – Core , 35 Sq. mm H.T AB Cable. 399 P/F of 11 KV cable termination kit for connecting 35 Sq mm XLPE cable (ABCtype) with the existing HT line near tapping point and HT transformer 400 Providing andfittingofLTDistributionboxforH.TtransformerwithMCCBFor incomer and SFU for outgoing circuits. 401 P/I of earthing station for electric substation,LTpanelandstabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other itemsrequired thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards.Safe earthing electrode size : 80 mm dia , Length : 2000 mmBack fill compound : 30 kg 402 Providing, installation, Testing & commissioning of 415 ±10%V (output), 3 phase 30kva air cooled cooled Diesel Generator set as per IS 8528 (2018) and ISO 3046 (2002) for engine and IEC/IS 60034-1 for alternator suitably assembled and fitted in a pollution free acoustic enclosure / canopy of required size (Rest Technical Specifications as per Annexure I) 403 Earth work inn excavation by manual means in trenches for foundations, drains, pipes, cables etc (not exceeding 1.5m in width) and for shafts, wells, cesspits and the like not exceeding10 Sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5m, including getting out excavatedearth and disposal of surplus excavated earth asdirected. 404 Providing and laying of soling stone 405 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shattering. All works upto plinth level with 1:2:4 mix (1 cement, 2cores sand, 4 graded stone aggregate 20mm nominal size) 406 Centering and shattering including strutting, propping etc. and removal of from work for foundation, footings, base for columns 407 Providing and fitting of L.T, 3.5core , 50 sqmm cable to work up to 1.1 KV , XLPE insulated , galvanized steel strip armored Almunium cable conforming to IS : 7098(part -1) 1988 With latest amendments to be fitted from D.G Set to Modular control panel . The job includes providing and fitting of suitable rating copper thimbles duly crimped and taped at conductor ends by hydraulic crimping tool. The job includes earth work in excavation whereverrequired for laying of cable underground.Make: L&T/ABB/Havells or equivalent 408 a) Providing of good quality bedding for night stay/Shift consisting of: -i) Mattress with warm cover size 6x3 (6Kg)- 02 No’sii) Quilt with warm cover size 5x8 (6Kg)- 02 No’siii) Pillows with covers - 02 No’siv) Single bed warm blankets with one sided Fur- 02 No’sThe filling material for mattress, quilt and pillow shall be of goodquality cottonb) The job also includes providing of pressure cooker 5ltr 02 No’s, Steel patella (utensil) 5ltrs 02 No’s, cooking heater 01 No., room heater 01 No., steel buckets 10 litre capacity 01 No., Plastic bucket 10 litre capacity with Mug 02 No’s each, steel glasses 06 No’s, steel Plates with large spoons and bowls 03 No’s each, Cup and Saucer set (01 No. Set) and, 5kg Gas cylinder with burner/ stove. The job also includes providing of thermo- cool 15’x12’ along with excel matting of 15’x12’ size. The job also includes providing of unbreakable Plastic Chair table set consisting of chairs 04 No’s, extra heavy Table 01 No. The job also includes providing of good quality safety Door locks (03 No’s) of Godrej, Link locks, 409 Providing of 2 KW heat convector for operators for winter season 410 Fabrication of 6’ x 6’ angle iron bed by way of providing and fitting of Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded 411 Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 no’s including cutting , fixing all complete including painting of the play sheet by one coat of primer and two coats of enamel paint 412 Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro- mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications:Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. The rubber mats shall be accepted with manufacturers test certificate. 413 WSS JUHAMA NEW: Advt. Cost = 8.90Lacs( For Complete CIVIL Works Component) 414 CIVIL WORKS (SUMP) 415 Earth work in excavation by manual means over areas exceeding 30 cms & upto 5 m in depth 1.5m in width as well as 10 sqm. On plan, disposal of excavated earth upto 1 m, disposed earth to be levelled & neatly dressed(all kinds of soils) 416 Providing & Laying of stone soling (dully hand packed)including watering dressing and ramming with all carriages loading un-loading and stacking etc complete 417 Providing & laying in position cement concrete of specified grade excld. The cost of centring and shuttering all work upto plinth level(1:4:8 coarse sand 40 mm nominal size crushed stone agg.) 418 P/L in position specified grade of reinforced cement cencrete (1:1.5:3) mix excld. the cost of centring, shuttering, finishing and reinforecement- All work upto plinth level. With stone agg. 20mm nominal size 419 Raft 420 Walls 421 P/L of Reinforced cement concrete 1:1.5:3 mix with 20-mm nominal size aggregates including curing but excluding cost of shuttering 422 Centring and shuttering incld. Strutting, proping etc & removal of form work for Founadtions, footings, bases of columns for mass concrete 423 Raft 424 Walls Internal and External 425 Suspended Floors 426 Edges of Slabs 427 Reinforcement for RCC work incld straightning, cutting, bending, placing in position & binding all complete (Thermo-mechanically treated bars) 428 P/L 12-mm thick cement plaster in 1:3 with floating coat of neat cement 429 Brick work for superstructures in 1:6 mix. 430 Extra for brick work for superstructure. 431 Providing wood work for doors and windows (1st Clas kail wood). 432 Providing and fixing of glazed shutters 35mm thick. 433 Structural steel welded in built up sections in trusses, frames, wraught, purlins etc. 50x50x6mm 434 CGI sheet roofing 0.63mm thick. 435 Finishing walls with water proof paint applied @ 4.84kg/10 Sqm 436 Providing and applying white cement based putty of specified thickness of approved brand and manufacture. (2mm thick) 437 Painting with synthetic enamel of approved brand and manufacture (two or more coats). 438 Carriage of materails By Mech.Transport, from source to site of work 439 Sand/Stone Agg. for an avg lead of 30 km 440 Cement for an avg lead of 05 km 441 Steel for an avg lead of 15 km 442 Stone soling for an avg. lead of 30 km 443 WSS MAMATH NAGRADKAH: Advt. Cost = 36.29 Lacs( For Complete Electro Mechanical Component) 444 Supply, Installation, Testing & Commissioning of Open Well Pumping Units as per 14220.PUMP: - • Type of pump:Open wellSubmersible Pump (vertical )• Quality of Water to be handled :Filter water• Discharge: 5000 GPH• Head: 112 mtrs (Rest Technical Specifications as per Annexure C 5 ) 445 Fabrication, providing and fitting of split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. 446 S/I/T/C of suitable size of GI nipple for pumping equipment at Sr. No.01. The nipple shall be threaded one side as per outlet of pump and weld with suitable size MS flange as per the size of the rising main/ pump delivery. 447 Providing and fitting of 10 Sq.mm 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipment. The cable connections terminal shall be fitted with copper thimbles of required size.Make: L&T/ABB/Havells or equivalent 448 Fabrication, Providing and fitting of Modular motor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories(Rest Technical Specifications as per Annexure C 5 ) 449 Providing, fitting, testing and commissioning of 40KVA voltage stabilizer as per (Rest Technical Specifications as per Annexure C 5 ) 450 Providing and Fitting of 3.5-Core, 50mm²XLPE, 1.1KV and 11KV grade Armoured Aluminum Cable of various sizes conforming toIS:7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. To be fitted from change over panel to modular panel. The job also includes P/F of Aluminumthimbles of various sizes as per size requirement including crimping and tapingMake: L&T/ABB/Havells or equivalent 451 Providing/supplying and fitting of 80mm dia G.I flanged Rising Main at site.The Pipe shall be hot dip Galvanized, class C confirming to IS 1239.The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. Flanges (as per IS 6392/1997 Table: 17) Thickness shall conform toIS6392Part1stTable-17.The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint. Welding Electrode DC Arc Welding using welding electrode having diameter not less than 4mm. Nuts and Bolts Nuts and Bolts (conforming to IS:1363 Part 1st) Rubber Insertion Gaskets Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. Make: TATA/prakash/Surya/Jindal or equivalent 452 Fabrication / Providing / Fitting of Delivery Manifold with wash out arrangement fabricated out of (Class – C) GI pipe 80 mm and welded with 18 mm thickMS flange as per Table – 5 in two runs of welding . The job also includes cost on account of suitable size nuts, bolts and rubber packing in the flanged joints. The job also includes (12 mtrs) of GI 80 mm pipe arrangements for fitment of pumping equipment in the sump. 453 Providing and fitting of Ductile Iron double flanged, Slanted seat swing check valve( NRV) 80mm as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approvedfordrinkingwater).The valve shall be compatibleforburiedapplicationsandshallbesafetoinstall in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve.Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos.M.Sflangesperfectly adaptable to the inbuilt flanges of the valve which shall be fittedwithRising main of the pumping unit atappropriatespotsaspersiterequirement.The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. Make: VAG/Kirloskar/AVK or equivalent 454 Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves 80 mm as per IS14846 for regulating the water supply outside the pumping units.The body and bonnent of the valve shall be of ductile iron, wedge with fully vulcanized EPDM rubber (Approved for drinking water) and NBR seal. The Gate/Sluice valveshallbecompatibleforburiedapplicationsandshallbe safe to install in both horizontal and vertical positions It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos.M.Sflangesperfectly adaptable to the inbuilt flanges of the valve which shallbe fittedwithrising main of the pumping unit atappropriatespotsaspersiterequirement.The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. Make: VAG/Kirloskar/AVK or equivalent 455 Fabrication, providing and fitting of washout Tee with arm length 1.2 feet each (Approx). The Tee shall be fabricated out of G.I C-class pipe with M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) fastened with weld joints on three ends. The size of the Tee is given Below: The job further includes Providing and Fitting of nuts and bolts (conforming to IS:1363 Part 1st) and Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The size of the T- junction is given below : Dia of the Pipe=80mm 456 Providing, fitting, testing and commissioning of ARV (Air Release valve) as per IS 14845 to be fitted to G.I rising Main. The ARV Shall have the following specifications: -Valve type - single chamber, single orifice.End connection - flanged ends to IS 1538 Working temperature - 70oc to 550 cTest pressure - body / seat 2.5 x PNSealing ring - EPDMConstruction -ductile iron with stainless steel floats Coating - epoxy with corrosion resistance Besides the above works, The job also cost on account of P/F R.I gasket, nuts and bolts required for installation of ARV and arrangement of gas cutter/ welding set at site.Make: VAG/Kirloskar/AVK or equivalent 457 Fabrication of gantry mechanism by way of providing Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete Welded The job also includes painting of complete Structure in one coat of red oxide and 02 coats of enamel metal paint.Vertical Posts = ISMC 200No. of vertical posts = 02 Nos.Vertical channel section each post = 02 Nos(seam welded face to face).vertical post bracing = ISMC 100Sole / Matching plates = 500x300x12 thickHeight of vertical posts = 5 Msize of vertical post concrete blocks = 600x600x900 mm(Depth)Concrete grade = M20welding Electrode = Overcord SS of Adore/ESAB/L&T/AdvaniMonorail Section = ISHB 250length of monorail = 5MSteel Detail :i. ISMC 200 5Mx2x2 = 20 M @ 22.3kg/m = 446 kgIi ISMC100 0.25Mx8x2x2 = 8 M@ 9.2kg/m = 73.60 kgiii Plate 0.500x0.300x8 (12mmthk) = 1.20 M²(12thk) = 112.80 kgIv Monorail ISHB250 5 M @ 51.4 kg/M = 257kgsV Bolts/Nuts (L.S) = 30kgs Total = 919.4 Kg say 920 Kg. 458 Providing, installation andtestingofmanualtypetriplespurgearchain pulley block having following features:Gears:- The hoist shall have precision machine case Hardened alloy steel gear mountedonbearingsandhousedina dustproofgearbox.Thelubrication of gears should be of high viscosity and temperature for longer life of gears.Load Chain:- The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation.Load chain wheel:- the load chainwellshouldbedoubleballbearing supportedandSpeciallydesigned,perfectlymachinedwheelproviding correct grip of load chain to makes the hoist most safe and reliable against any failure. The main specifications of C.P Block are given below :Make = Pull Lift/Indef or equivalentCapacity = 2 ton (P) No. Of load chain falls = 2 or above Min. Height of lift = 6 M 459 Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover. with 2-core 4 mm2 Cu ( 25 m) wiring as per site requirement along withotheraccessorieslikeSS-Combine(02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item.Make = Exide/Luminous or equivalent 460 Electrification of Pump House by way of P/F of:-Lighting points in 1.0 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 5 Amp. Switch, angle / button holder, 9 W LED lamps with necessary fixtures. – 08 jobsLighting points, bulk head type in 1.0 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 5 Amp. switch, angle / button holder, 9 W LED lampwith necessary fixtures – 06 jobsHeating points in 2.5 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 16 Amp. SS combine- 04 jobs5-pin socket points in 1.5 sq mm multi strandPVC insulated copper conductor to be laid / carried in PVC channel/conduit.- 04 jobs Indicator pointsin 1.0 sq mm multi strandPVC insulated copper conductor to be laid / carried in PVC channel/conduit – 04 jobsCeiling Fan with regulator switch, wiring in 1.5 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. and necessary fixtures. – 02 jobs Distribution Board SP & N ( Regal Grey ) with 01 No incoming and8 way outgoing, fitted with mini MCB “C” series 6A -04 No for lighting points and 2/3 pin socket points and fans, 10 A – 02 No for flood lights, 16 Amp – 02 No for heating points, 63 Amp MCB ( Mains ) – reputed make. The job also includes supply of 05KW sine wave voltage stabilizer single phase 90 – 270 V input for a constant output of 240 V. The fittings shall be modular type of reputed make 461 Illumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mmwide,thickness3mmwith70 Microns Zinc coating having inside arrangement for providing of power connection along with following items.3 Way Terminal Connector 20 Amp.3 No MCB 8 Amp.The job includes fabrication, providing and fitting of three arm GI structure at the top having 120° angle between arms and each arm having 15° inclination with respect to horizontal plane. Each arm should be of 2’ length and size and shape appropriate as per requirement of the luminary.The job also includes providing and fitting of required length of flexible multi strand 2 mm copper wire from each terminal connector to each holding arm. The pole is mounted on 1:2:4 Cement concreting of size not less than 2’x2’x6” (cost of concreting not included in the job) using 04 No anchor bolts of required size not less than 7” in length. The complete job includes earthing in GI Electrode as per relevant IS Code 462 Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole vide item No.36Having following specs:Input: 90-240 V 50 HzPower Factor: >0.9Colour Temperature: 4K - 6.5KBeam Angle: 120° - 170°Lumens: >12000Operating Temperature: -20°C to 60°CThe LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection up to IP-68.The LED is properly fitted on the arm of the pole and connected to the copper wire as provided inthe high mast poleMake = Havells/L&T/Crompton or equivalent 463 Providing and installation of Junction Box with DP 32 A MCB to serve as Main switch for LED Lighting. The job includes making of electric connection to the circuit. 464 Providing and carriage of Tool sets comprising of following items as mentioned below, for day today maintenance of Electro-Mechanical equipment’s installedat water supply scheme. The job shall include cost on account of carriage/transportation of tool set to thewater supply scheme. The tools are to be provided in a strong tool box with key and lock mention below of reputed IS makei. Open end Spanner of Size (4/5 to 30/32) (01 complete set)ii. Ring Type Spanner of Size (4/5 to 30/32) (01 complete set)iii. Pliers, 9 inch: (01 No)iv. Nose Pliers 9 inch: (01No)v.Screw Driver 12 inch & 06 Inch:( 01 No Each)vi.Hammer with wooden handle, I Kg (01 No)vii.Pipe Wrench 12 inch: (01 No)viii Electric Multimeter =1No ix. Digital multimeter – 1No. x. Digital Clamp tester capable to measure up to 400A - 1 No. xi. Hack saw frame with hack saw blade – 01 no. Make = Taparia/Jhalani /Everest or equivalent 465 Supply , installation , commissioning and creation of pole mounted, outdoor type Electric Sub Station as per the technical specifications given here under-Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments. Type: HT/LT Transformer Type of cooling: ONAN. Operating conditions:Capacity = 100KVA (level-2)Input =11000 voltsOutput =433 volts AC supply in 3- phase. Terminals:Input=3 No. HT bush rods with insulators, washer, nuts etc. Output=4 No. LT bush rods switch insulators, washers, nuts etc.Core: The core shall be of high permeability to reduce core losses and the strips shall be of suitable size and gauge.Transformer Coils:Suitable number of HT and LT coils in each leg of the core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage, and all leads and lifts involved.The HT transformer shallbeofreputed makefroman ISO certifiedcompany as per relevant standards and a test certificate shall be provided before installation. The transformer shall also beprovidedwithbreatherfillwith silica jel crystals, conservator with oil level indicator,explosionvetand adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS: 1180 (Part 1) 2014 with latest amendments.NOTE: The scope of the work shall include obtaining of necessaryinspection/clearance certificate from the concerned department for all the required equipment. The testing and commissioning shall be completed only after obtaining above certificate. 466 Providing and fitting G.I Channel /Angle/ Flat of sizes including clamps ( for transformer bed, taping point , brackets of poles etc) 467 Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. 468 Supply, Installation, Testing and commissioning of 11KV polymer fuses Set Horn Gap 3-phase 200 A suitable for vertical installation. 469 Supply, Installation, Testing and commissioning of Gapless Surge arrestor station class,LA With polymer housing, Station Type. 470 Supply and fitting of 11 KV polymeric composite pin / disc insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creep age distance 320mm 471 Supply, installation, erection of 9 mtrs long H.T pope of specifications ST-410 (sp-33) . The job further includes drilling of holes for installation of various accessories .wherever required the job further includes G.I wire earthing of pole as per REC standard. 472 P/F of Galvanized nuts, bolts of various sizes as per site requirement. (for fitment of electric sub station, poles etc) 473 P/F Danger Plate with clamps 474 Providing and fixing G.I Barbed wire for anti-climbing/ anti-climbing devices 475 Providing and fitting of Galvanized stay set with 50 X 8 mm Stay Clamp , Guy insulator (2no.), Anchor plate (200X200X6mm) , nuts and bolts , 2 N0- turn buckle , 1.8 m long , 16 mm diameter solid G.I stay rod & 7/3.15 mm dia. G.I stranded wire complete. 476 Painting of poles Red oxide for 37Poles 477 Painting of poles Aluminum paint for 37 Poles 478 Providing, Laying and fitting of ACSR Conductor as per relevant IS standard 0.5 ACSR Conductor 479 Providing and fitting of Anchoring clamps comprising clamp body , plastic wedge, steel bill bracket , straps and buckles or nuts and bolts required for holding of 3 – Core , 35 Sq. mm H.T AB Cable. 480 P/F of 11 KV cable termination kit for connecting 35Sq mm XLPE cable (ABC type) with the existing HT line near tapping point and HT transformer. 481 Providing andfittingofLTDistributionboxforH.TtransformerwithMCCB For incomer and SFU for outgoing circuits. 482 P/I of earthing station for electric substation, LT panel and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards.Safe earthing electrode size : 80 mm dia, Length : 2000 mmBack fill compound : 30 kg 483 Providing, installation, Testing & commissioning of 415 ±10%V (output), 3 phase 50KVA Water cooled Diesel Generator set as per IS 8528 (2018) for engine and IEC/IS 60034-1 for alternator suitably assembled and fitted in a pollution free acoustic enclosure / canopy of required size(Rest Technical Specifications as per Annexure C 5) 484 Earth work inn excavation by manual means in trenches for foundations, drains, pipes, cables etc (not exceeding 1.5m in width) and for shafts, wells, cesspits and the like not exceeding10 Sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5m, including getting out excavatedearth and disposal of surplus excavated earth asdirected. 485 Providing and laying of soling stone 486 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shattering. All works upto plinth level with 1:2:4 mix (1 cement, 2cores sand, 4 graded stone aggregate 20mm nominal size) 487 Centering and shattering including strutting, propping etc. and removal of from work for foundation, footings, base for columns 488 a) Providing of good quality bedding for night stay/Shift consisting of: -i) Mattress with warm cover size 6x3 (6Kg)- 02 No’sii) Quilt with warm cover size 5x8 (6Kg)- 02 No’siii) Pillows with covers - 02 No’siv) Single bed warm blankets with one sided Fur- 02 No’sThe filling material for mattress, quilt and pillow shall be of good quality cottonb) The job also includes providing of pressure cooker 5ltr 02 No’s, Steel patella (utensil) 5ltrs 02 No’s, cooking heater 01 No., room heater 01 No., steel buckets 10 litre capacity 01 No., Plastic bucket 10 litre capacity with Mug 02 No’s each, steel glasses 06 No’s, steel Plates with large spoons and bowls 03 No’s each, Cup and Saucer set (01 No. Set) and, 5kg Gas cylinder with burner/ stove. The job also includes providing of thermocool 15’x12’ along with excel matting of 15’x12’ size. The job also includes providing of unbreakable Plastic Chair table set consisting of chairs 04 No’s, extra heavy Table 01 No. The job also includes providing of good quality safety Door locks (03 No’s) of Godrej, Link locks, 489 Providing of 2 KW heat convector for operators for winter season 490 Fabrication of 6’ x 6’ angle iron bed by way of providing and fitting of Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded 491 Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 no’s including cutting , fixing all complete including painting of the play sheet by one coat of primer and two coats of enamel paint 492 Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro- mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. The rubber mats shall be accepted with manufacturers test certificate. 493 WSS MAMATH NAGRADKAH: Advt. Cost = 20.47 Lacs( For Complete CIVIL Works Component) 494 CIVIL WORKS (SUMP CUM PUMP HOUSE) 495 Earth work in excavation by mehanical means over areas exceeding 30 cms & upto 5 m in depth 1.5m in width as well as 10 sqm. On plan, disposal of excavated earth upto 1 m, disposed earth to be levelled & neatly dressed( all kinds of soils) 496 Extra for additional one lift 497 Providing & Laying of stone soling (dully hand packed)including wateringdressing and ramming with all carriages loading un-loading and stacking etc complete 498 Providing & laying in position cement concrete of specified grade excld. the cost of centring and shuttering all work upto plinth level(1:4:8 coarse sand 40mm nominal size crushed stone agg.) 499 P/L in position specified grade of reinforced cement cencrete excld. The cost of centring, shuttering, finishing and reinforecement-All work upto plinth level. 1:1.5:3 stone agg. 20mm nominal size 500 P/L in position specified grade of cement cencrete (1:1.5:3) excld. The cost of centring, shuttering, finishing and reinforecement-All work upto plinth level stone agg. 20mm nominal size 501 RCC wall anythick 502 Suspended Floors at top sump level and P/H floor level 503 Brickwork in common burnt clay FPS bricks of class designed 75 in foundation in 1:4 mix 504 Extra for brick work in superstructure above plinth level upto floor V level. (By manual means) 505 Providing and fixing of wrought framed chowkats in wood work of 2nd class Deodar wood 506 Providing and fixing of pannalled/pannelled or glazed shutters 35-mm thick of 2nd class deodar wood including 4.0 mm thick glasss panes 507 Providing and fixing 35mm thick wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge 2nd class deodar wood 508 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. 509 Providing/fixing of hinges of sizes, handles, haldarwazs, latches incl. screws of sorts all complete job. 510 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutter80x1.20 mm M.S. laths with 1.20 mm thick top cover 511 Shutter 512 Ball Bearing 513 Reinforcement for RCC work incld straightning, cutting, bending, placing inposition & binding all complete (Thermo-mechanically treated bars) 514 Centering and shuttering incld. Strutting, proping etc & removal of form work for Founadtions, footings, bases of columns for mass concrete 515 Foundation 516 Walls 517 Sump/Pump Floor Level 518 Edges 519 P/L 12-mm thick cement plaster in 1:4 520 Providing and fixing Ist quality ceramic glazed tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer¬in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 521 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 522 Applying priming coat With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 523 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an even shade two or more coat icluding priming coat (walls interior and exterior and wood work) 524 Steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position amd applying a priming coat of approved steel primer using structural steel 525 Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gram/m2 526 OP. Qtr 25 x 28 = 700 Sft @ 2.5 527 Eves boardings 528 Ridges or hips of width 60cm overall width 0.63 mm thick 529 Carriage of materials By Mech.Transport, from source to site of work 530 Sand andStone agg. for an avg lead of 15 km 531 Cement from Div. Store for an avg lead of15 km 532 Bricks for an avg. lead of 26 km 533 Stone soling for an avg. lead of 15 km