Agriculture Cooperative Closing in 0 days TDR #33062369

Electrical Items Electrical Items , Local Remote Sel. Switch16a , Stayput, Lockable In Both Position Wing Type Knob, Rotary Switch , Size 75 X 75 Mm, 3 Contact To Close In Each Position Make- Switron , Zno Surge Arrestor Polymeric Housing, System

Issued by Cooperative · rohtak, Haryana
Tender Value
Ref. Documents
Estimated cost
Bid Submission
20 Jul 2022
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
100
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
rohtak → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Electrical Items Electrical Items , Local Remote Sel. Switch16a , Stayput, Lockable In Both Position Wing Type Knob, Rotary Switch , Size 75 X 75 Mm, 3 Contact To Close In Each Position Make- Switron , Zno Surge Arrestor Polymeric Housing, System Voltage 11 / 6.6 Kv Rated Voltage 9 Kvorder No. Pbw-9C1 Maximum Continuous Operating Voltage 7.2 Kv, Class 1, Normaldischarge Current 10 Ka Make- Oblum , Copper Flexible For Bus-Bar Non Cross-Sectional Mm², 185 Mm², 570 A With Standard Length Make- Good Quality , Copper Flexible For Bus-Bar Non Cross-Sectional Mm², 300Mm², 780 A With Standard Length , Copper Flexible For Bus-Bar Non Cross-Sectional Mm², 500 Mm², 1100 A With Standard Length , Copper Flexible For Bus-Bar Non Cross-Sectional Mm², 800 Mm², 1500 A With Standard Length , Copper Flexible For Bus-Bar Non Cross-Sectional Mm², 1000 Mm², 1800 A With Standard Length , Power Factor Meter 1A, 110Vac, 969F310.5-1-0.5 Make- Meco , Breaker Control Switch, Spring Return To Neutral, 2 Trip , 2 Close, 32 A, 440Vac / Dc , Contact With Piston Grip Handle Make- Switron , Breaker Selector Switch , One Pole , 3Way With Off-16 Ampere Stay Put, 440 V .D.C Make- Switron , Thermister Make- Good Quality , 11 Kv Porcelain Insulator For Ht Panels Bus Bar Supporting Suitable With 11Kv , Ka 25 As Per Sample , Heat Shrink And Termination Outdoor Cable Joint Kit Size 3 X 240 Sq. Mm, Xlpe Cable , 11Kv Make- Rechem , Heat Shrink And Termination Indoor Cable Joint Kit Size 3X300 Sq. Mm, Xlpe Cable 11 Kv Make- Rechem , Old Dhoti 05 ( Meters ) Good Quality , Painting Brush 2”, 4”, 3” Good Quality , Nicrom Wire , Red Insulating Vvanish , Thinner , Voltage Transformer Pt 1100 / V3 / 110 / V3 / 110 / V3 Type- Earthed Pri ( Volts ) – 11000 / V3 Type ( Dei ) Winding Sector Connvolts110 / V3, 110 / V3, Il : 12 / 28 / 75 Kvpva / Ph 5050, V:F1:2Continuous And 1.9 For 8 Hours, Class 0.2, 3Phase , Frequency 50 Hz , Phase 1. Tern 9-N , Da-Dr, Insulation Level – Class B For Earthed V ( -N” Terminal Must Be Earthed Externally Make- Pragati As Per Drawing , Panel Connection On Motor Terminals D / N Rail Mountedany Good Quality , 10 Sq. Mm Any Good Quality , 15 Sq. Mm Any Good Quality , 25 Sq. Mm Any Good Quality , 35 Sq. Mm Any Good Quality , 50 Sq. Mm Any Good Quality , 45 Sq. Mm Any Good Quality , 65 Sq. Mm Any Good Quality , Closing & Tripping Coil Of C500, Kirloskar Make Vcb Type – Wound , 110Vdc Make- Kirloskar , Proximity Sensor 10-30 Volts, Dc, Dia 15 X 400 Mm , Type Pnp Make- Jaishree , Foot Switch Complete 230 V Ac , With 2 No+ 2Nc Make- Bch , Lt Meggar0-500 Volts D.C Handle Rotating Type Make- Pico , Ht Meggar 0-5000Volts D.C Handle Rotating Type Make- Pico , Poecelin Pipe 24” X 1” Make- Any Good Quality , Discrepancy Type Breaker Control Switch , 3 Position , 8 Way , Spring Return Handle Contact Close-3 No, Trip-3 No, 2 No For Nat / Nac, 25 A, 110V D.C Make- Dav / Multimodel / Equl , Local Remote Sel. Switch16a , Stayput, Lockable In Both Position Wing Type Knob, Rotary Switch , Size 75 X 75 Mm, 3 Contact To Close In Each Position Make- Switron , Zno Surge Arrestor Polymeric Housing, System Voltage 11 / 6.6 Kv Rated Voltage 9 Kvorder No. Pbw-9C1 Maximum Continuous Operating Voltage 7.2 Kv, Class 1, Normaldischarge Current 10 Ka Make-Oblum , Semaphore, Type 110V Dc 48Mm Dia With 3K Ohm Resistor Make- Dav , Dc-Dc Converter 110V Dc / 2V Dc , 5 Amake- Gallent , Kw Meter, Digital 96X48 Sq. Mm , Ctr: 1250 / 1A, Ptr 11 Kv / V3 / 110 / V3 Range 0-21000Kwcl 0.5 Make- Conzan , Pe Meter , Digital Pf Meter 3 Phase , 4 Wire 96X48sq. Mm , Ctr 1250 / 1A, 11Kv / V3 / 110V / V3 0.5Lag-1-0.5 Lead Cl 0.5 Make-Conzav , Pmg Under / Over Voltage Relay, System Voltage 220 V / 3 Phase, 50 Hz Make- Minilec , Selector Switch, 6 Pole 2 Way With Out O / G 440V, 10A Make- Kaycee , Resistor With Variable Load 100E, 100W, Wire Wound Make- Pec , Rectifier Chassis Unit Casing Of Three Phase Bridge Rectifier Br-1, D1, D3 & Anode Diode Block D4, D5, D6 Make- Sanelec , Diode Card With 14 Nos. , Comman Anode Diodes And 2 Nos. Common Cathod Diodes Make-Sanelec , 3 Phase Squirrel Cage Induction Motor Kw- 0.12 / 0.10 Hp, 0.5 Ampere, 415V, 50 Hz , Rpm 1440, Frame 71 Make- Ctr , 3 Phase Squirrel Cage Induction Motor Kw- 3.7 07Ampere, 415V, 50 Hz , Rpm 2900, Duty – Si, Connection Delta, M / C 00M 2007006-129 , F Class Insulation Make- Integrated Electric , 3 Phase Squirrel Cage Induction Motor Kw- 0.37 1.05Ampere, 415V, 50 Hz , Rpm 1380, Duty – Si, F Class Insulationframe 71 Make- Siemens , 3 Phase Squirrel Cage Induction Motor Kw- 0.37 1.05Ampere, 415V, 50 Hz , Rpm 1380, Duty – Si, F Class Insulationm / C No. Taa-32-1608, Connection Starmake-Kirloskar, Primo , 3 Phase Squirrel Cage Induction Motor Kw- 3.7 7.4 Ampere, 415V, 50 Hz , Rpm 1440, Duty – Si, Connection Delta, Frame 112M , F Class Insulationmake- C.G , 3 Phase Squirrel Cage Induction Motor Kw- 15 27 Ampere, 415V, 50 Hz , Rpm 1440, Duty – Si, Connection Delta, Frame Nd 162 L , F Class Insulation Make-C.G , Filter Pad For 145 Kw, Dc Motor Integrated Motor Any Good Quality , Copper Lug Ring Type, Long Size, Heavy Duty ( I ) 25 Sq. Mm Make- Dowells , Copper Lug Ring Type, Long Size, Heavy Duty 35Sq. Mm Make- Dowells , Copper Lug Ring Type, Long Size, Heavy Duty 70Sq. Mm Make- Dowells , Copper Lug Ring Type, Long Size, Heavy Duty 120Sq. Mm Make- Dowells , Aluminum Cable Lug, Long Size , Heavy Duty240 Sq. Mm Make- Dowells , Aluminum Cable Lug, Long Size , Heavy Duty150 Sq. Mm Make- Dowells , Aluminum Cable Lug, Long Size , Heavy Duty120 Sq. Mm Make- Dowells , Aluminum Cable Lug, Long Size , Heavy Duty70 Sq. Mm Make- Dowells , Aluminum Cable Lug, Long Size , Heavy Duty25 Sq. Mm Make- Dowells , Aluminum Cable Lug, Long Size , Heavy Duty10 Sq. Mm Make- Dowells

BOQ

Name of Work: ELECTRICAL ITEMS
Sl. No. Item Description
1Local remote Sel. Switch16A , Stayput, lockable In Both position wing Type Knob, Rotary Switch , Size 75 x 75 mm, 3 contact to close in each position Make- Switron
2ZNO Surge Arrestor Polymeric Housing, System voltage 11/6.6 KV Rated voltage 9 KVorder no. PBW-9C1 maximum continuous operating voltage 7.2 KV, class 1, NormalDischarge current 10 KA Make- Oblum
3Copper flexible for BUS-BAR Non cross-sectional mm², 185 mm², 570 A with standard length Make- Good quality
4Copper flexible for BUS-BAR Non cross-sectional mm², 300mm², 780 A with standard length
5Copper flexible for BUS-BAR Non cross-sectional mm², 500 mm², 1100 A with standard length
6Copper flexible for BUS-BAR Non cross-sectional mm², 800 mm², 1500 A with standard length
7Copper flexible for BUS-BAR Non cross-sectional mm², 1000 mm², 1800 A with standard length
8Power factor meter 1A, 110VAC, 969F310.5-1-0.5 Make- Meco
9Breaker control Switch, Spring return to neutral, 2 Trip , 2 close, 32 A, 440VAC/DC , contact with piston grip handle Make- Switron
10Breaker selector switch , one pole , 3way with off-16 Ampere Stay put, 440 V .D.C Make- Switron
11Thermister Make- Good quality
1211 KV Porcelain insulator for HT panels Bus Bar supporting suitable with 11KV , KA 25 as per sample
13Heat Shrink and termination outdoor cable joint kit size 3 x 240 Sq. mm, XLPE cable , 11KV Make- Rechem
14Heat Shrink and termination indoor cable joint kit size 3x300 sq. mm, XLPE Cable 11 KV Make- Rechem
15Old Dhoti 05 (Meters) good quality
16Painting brush 2”, 4”, 3” good quality
17Nicrom wire
18Red insulating vvanish
19Thinner
20Voltage Transformer PT 1100/v3/110/v3/110/v3 Type- Earthed PRI (Volts) – 11000/v3 Type (DEI)winding sector CONNVolts110/v3, 110/v3, IL : 12/28/75 KVPVA/PH 5050, V:F1:2continuous and 1.9 for 8 hours,class 0.2, 3phase , frequency 50 Hz , Phase 1. tern 9-n , da-dr,Insulation level – Class B for earthed V(-N” terminal must be earthed externally Make- Pragati as per drawing
21Panel connection on Motor terminals D/N Rail MountedAny good quality
2210 Sq. mm Any good quality
2315 Sq. mm Any good quality
2425 Sq. mm Any good quality
2535 Sq. mm Any good quality
2650 Sq. mm Any good quality
2745 Sq. mm Any good quality
2865 Sq. mm Any good quality
29Closing & Tripping coil of C500, Kirloskar Make VCB Type – Wound , 110VDC Make- Kirloskar
30Proximity Sensor 10-30 Volts, DC, Dia 15 x 400 mm , Type PNP Make- Jaishree
31Foot Switch complete 230 V AC , with 2 NO+ 2NC Make- BCH
32LT Meggar0-500 Volts D.C Handle rotating type Make- PICO
33HT Meggar 0-5000Volts D.C Handle rotating Type Make- PICO
34Poecelin pipe 24” x 1” Make- Any good quality
35Discrepancy Type Breaker control switch , 3 position , 8 way , Spring return handle Contact close-3 No, Trip-3 No, 2 No for NAT/NAC, 25 A, 110V D.C Make- DAV/Multimodel/Equl
36Local remote Sel. Switch16A , Stayput, lockable In Both position wing Type Knob, Rotary Switch , Size 75 x 75 mm, 3 contact to close in each position Make- Switron
37ZNO surge Arrestor Polymeric Housing, System voltage 11/6.6 KV Rated voltage 9 KVorder no. PBW-9C1 maximum continuous operating voltage 7.2 KV, class 1, NormalDischarge current 10 KA Make-Oblum
38Semaphore, Type 110V DC 48mm Dia with 3K Ohm Resistor Make- DAV
39DC-DC Converter 110V DC/ 2V DC , 5 AMake- Gallent
40KW Meter, digital 96x48 Sq. mm , CTR: 1250/1A,PTR 11 KV/ v3/110/v3 Range 0-21000KWCL 0.5 Make- Conzan
41PE Meter , digital PF Meter 3 phase , 4 wire 96x48Sq. mm ,CTR 1250/1A, 11KV/v3/110V/v3 0.5lag-1-0.5 lead CL 0.5 Make-Conzav
42PMG under/over voltage relay, system voltage 220 V/3 phase,50 Hz Make- Minilec
43Selector switch, 6 Pole 2 way with out o/g 440V,10A Make- Kaycee
44Resistor with variable load 100E, 100W, wire wound Make- PEC
45Rectifier chassis unit casing of three phase bridge rectifier BR-1,D1,D3 & Anode Diode block D4,D5,D6 Make- Sanelec
46Diode card with 14 Nos. , comman Anode diodes and 2 Nos. common Cathod Diodes Make-Sanelec
473 Phase squirrel cage Induction Motor KW- 0.12/0.10 Hp, 0.5 Ampere, 415V, 50 Hz , RPM 1440, Frame 71 Make- CTR
483 Phase squirrel cage Induction Motor KW- 3.7 07Ampere, 415V, 50 Hz , RPM 2900, Duty – SI, Connection Delta, M/C 00M 2007006-129 , F class insulation Make- Integrated electric
493 Phase squirrel cage Induction Motor KW- 0.37 1.05Ampere, 415V, 50 Hz , RPM 1380, Duty – SI,F class insulationFrame 71 Make- Siemens
503 Phase squirrel cage Induction Motor KW- 0.37 1.05Ampere, 415V, 50 Hz , RPM 1380, Duty – SI,F class insulationM/C No. TAA-32-1608,Connection StarMake-Kirloskar, Primo
513 Phase squirrel cage Induction Motor KW- 3.7 7.4 Ampere, 415V, 50 Hz , RPM 1440, Duty – SI, Connection Delta, Frame 112M , F class insulationMake- C.G
523 Phase squirrel cage Induction Motor KW- 15 27 Ampere, 415V, 50 Hz , RPM 1440, Duty – SI, Connection Delta, Frame ND 162 L , F class insulation Make-C.G
53Filter pad for 145 KW, DC Motor Integrated motor Any good quality
54Copper Lug Ring type, long size, heavy duty (i) 25 Sq. mm Make- Dowells
55Copper Lug Ring type, long size, heavy duty 35Sq. mm Make- Dowells
56Copper Lug Ring type, long size, heavy duty 70Sq. mm Make- Dowells
57Copper Lug Ring type, long size, heavy duty 120Sq. mm Make- Dowells
58Aluminum cable lug, Long Size , Heavy Duty240 Sq. mm Make- Dowells
59Aluminum cable lug, Long Size , Heavy Duty150 Sq. mm Make- Dowells
60Aluminum cable lug, Long Size , Heavy Duty120 Sq. mm Make- Dowells
61Aluminum cable lug, Long Size , Heavy Duty70 Sq. mm Make- Dowells
62Aluminum cable lug, Long Size , Heavy Duty25 Sq. mm Make- Dowells
63Aluminum cable lug, Long Size , Heavy Duty10 Sq. mm Make- Dowells

AI Tender Summary

OUR REF NO 33062369
AUTHORITY Cooperative
TENDER VALUE Ref. Documents
LAST DATE 20-07-2022
Authority
Authority Name Haryana Sugar Federation
Work Description Electrical Items Electrical Items , Local Remote Sel. Switch16a , Stayput, Lockable In Both Position Wing Type Knob, Rotary Switch , Size 75 X 75 Mm, 3 Contact To Close In Each Position Make- Switron , Zno Surge Arrestor Polymeric Housing, System Voltage 11 / 6.6 Kv Rated Voltage 9 Kvorder No. Pbw-9C1 Maximum Continuous Operating Voltage 7.2 Kv, Class 1, Normaldischarge Current 10 Ka Make- Oblum , Copper Flexible For Bus-Bar Non Cross-Sectional Mm², 185 Mm², 570 A With Standard Length Make- Good Quality , Copper Flexible For Bus-Bar Non Cross-Sectional Mm², 300Mm², 780 A With Standard Length , Copper Flexible For Bus-Bar Non Cross-Sectional Mm², 500 Mm², 1100 A With Standard Length , Copper Flexible For Bus-Bar Non Cross-Sectional Mm², 800 Mm², 1500 A With Standard Length , Copper Flexible For Bus-Bar Non Cross-Sectional Mm², 1000 Mm², 1800 A With Standard Length , Power Factor Meter 1A, 110Vac, 969F310.5-1-0.5 Make- Meco , Breaker Control Switch, Spring Return To Neutral, 2 Trip , 2 Close, 32 A, 440Vac / Dc , Contact With Piston Grip Handle Make- Switron , Breaker Selector Switch , One Pole , 3Way With Off-16 Ampere Stay Put, 440 V .D.C Make- Switron , Thermister Make- Good Quality , 11 Kv Porcelain Insulator For Ht Panels Bus Bar Supporting Suitable With 11Kv , Ka 25 As Per Sample , Heat Shrink And Termination Outdoor Cable Joint Kit Size 3 X 240 Sq. Mm, Xlpe Cable , 11Kv Make- Rechem , Heat Shrink And Termination Indoor Cable Joint Kit Size 3X300 Sq. Mm, Xlpe Cable 11 Kv Make- Rechem , Old Dhoti 05 ( Meters ) Good Quality , Painting Brush 2”, 4”, 3” Good Quality , Nicrom Wire , Red Insulating Vvanish , Thinner , Voltage Transformer Pt 1100 / V3 / 110 / V3 / 110 / V3 Type- Earthed Pri ( Volts ) – 11000 / V3 Type ( Dei ) Winding Sector Connvolts110 / V3, 110 / V3, Il : 12 / 28 / 75 Kvpva / Ph 5050, V:F1:2Continuous And 1.9 For 8 Hours, Class 0.2, 3Phase , Frequency 50 Hz , Phase 1. Tern 9-N , Da-Dr, Insulation Level – Class B For Earthed V ( -N” Terminal Must Be Earthed Externally Make- Pragati As Per Drawing , Panel Connection On Motor Terminals D / N Rail Mountedany Good Quality , 10 Sq. Mm Any Good Quality , 15 Sq. Mm Any Good Quality , 25 Sq. Mm Any Good Quality , 35 Sq. Mm Any Good Quality , 50 Sq. Mm Any Good Quality , 45 Sq. Mm Any Good Quality , 65 Sq. Mm Any Good Quality , Closing & Tripping Coil Of C500, Kirloskar Make Vcb Type – Wound , 110Vdc Make- Kirloskar , Proximity Sensor 10-30 Volts, Dc, Dia 15 X 400 Mm , Type Pnp Make- Jaishree , Foot Switch Complete 230 V Ac , With 2 No+ 2Nc Make- Bch , Lt Meggar0-500 Volts D.C Handle Rotating Type Make- Pico , Ht Meggar 0-5000Volts D.C Handle Rotating Type Make- Pico , Poecelin Pipe 24” X 1” Make- Any Good Quality , Discrepancy Type Breaker Control Switch , 3 Position , 8 Way , Spring Return Handle Contact Close-3 No, Trip-3 No, 2 No For Nat / Nac, 25 A, 110V D.C Make- Dav / Multimodel / Equl , Local Remote Sel. Switch16a , Stayput, Lockable In Both Position Wing Type Knob, Rotary Switch , Size 75 X 75 Mm, 3 Contact To Close In Each Position Make- Switron , Zno Surge Arrestor Polymeric Housing, System Voltage 11 / 6.6 Kv Rated Voltage 9 Kvorder No. Pbw-9C1 Maximum Continuous Operating Voltage 7.2 Kv, Class 1, Normaldischarge Current 10 Ka Make-Oblum , Semaphore, Type 110V Dc 48Mm Dia With 3K Ohm Resistor Make- Dav , Dc-Dc Converter 110V Dc / 2V Dc , 5 Amake- Gallent , Kw Meter, Digital 96X48 Sq. Mm , Ctr: 1250 / 1A, Ptr 11 Kv / V3 / 110 / V3 Range 0-21000Kwcl 0.5 Make- Conzan , Pe Meter , Digital Pf Meter 3 Phase , 4 Wire 96X48sq. Mm , Ctr 1250 / 1A, 11Kv / V3 / 110V / V3 0.5Lag-1-0.5 Lead Cl 0.5 Make-Conzav , Pmg Under / Over Voltage Relay, System Voltage 220 V / 3 Phase, 50 Hz Make- Minilec , Selector Switch, 6 Pole 2 Way With Out O / G 440V, 10A Make- Kaycee , Resistor With Variable Load 100E, 100W, Wire Wound Make- Pec , Rectifier Chassis Unit Casing Of Three Phase Bridge Rectifier Br-1, D1, D3 & Anode Diode Block D4, D5, D6 Make- Sanelec , Diode Card With 14 Nos. , Comman Anode Diodes And 2 Nos. Common Cathod Diodes Make-Sanelec , 3 Phase Squirrel Cage Induction Motor Kw- 0.12 / 0.10 Hp, 0.5 Ampere, 415V, 50 Hz , Rpm 1440, Frame 71 Make- Ctr , 3 Phase Squirrel Cage Induction Motor Kw- 3.7 07Ampere, 415V, 50 Hz , Rpm 2900, Duty – Si, Connection Delta, M / C 00M 2007006-129 , F Class Insulation Make- Integrated Electric , 3 Phase Squirrel Cage Induction Motor Kw- 0.37 1.05Ampere, 415V, 50 Hz , Rpm 1380, Duty – Si, F Class Insulationframe 71 Make- Siemens , 3 Phase Squirrel Cage Induction Motor Kw- 0.37 1.05Ampere, 415V, 50 Hz , Rpm 1380, Duty – Si, F Class Insulationm / C No. Taa-32-1608, Connection Starmake-Kirloskar, Primo , 3 Phase Squirrel Cage Induction Motor Kw- 3.7 7.4 Ampere, 415V, 50 Hz , Rpm 1440, Duty – Si, Connection Delta, Frame 112M , F Class Insulationmake- C.G , 3 Phase Squirrel Cage Induction Motor Kw- 15 27 Ampere, 415V, 50 Hz , Rpm 1440, Duty – Si, Connection Delta, Frame Nd 162 L , F Class Insulation Make-C.G , Filter Pad For 145 Kw, Dc Motor Integrated Motor Any Good Quality , Copper Lug Ring Type, Long Size, Heavy Duty ( I ) 25 Sq. Mm Make- Dowells , Copper Lug Ring Type, Long Size, Heavy Duty 35Sq. Mm Make- Dowells , Copper Lug Ring Type, Long Size, Heavy Duty 70Sq. Mm Make- Dowells , Copper Lug Ring Type, Long Size, Heavy Duty 120Sq. Mm Make- Dowells , Aluminum Cable Lug, Long Size , Heavy Duty240 Sq. Mm Make- Dowells , Aluminum Cable Lug, Long Size , Heavy Duty150 Sq. Mm Make- Dowells , Aluminum Cable Lug, Long Size , Heavy Duty120 Sq. Mm Make- Dowells , Aluminum Cable Lug, Long Size , Heavy Duty70 Sq. Mm Make- Dowells , Aluminum Cable Lug, Long Size , Heavy Duty25 Sq. Mm Make- Dowells , Aluminum Cable Lug, Long Size , Heavy Duty10 Sq. Mm Make- Dowells
Basic Detail
Tender No ROHTAKSUGAR PUR/25.07.2022/49
Bidding Type Tender
Location
City rohtak
State Haryana
Key Dates
Publish Date 13 Jul 2022
Submission Date 20 Jul 2022
Open Date 20 Jul 2022
Finance
Tender Value Ref. Documents
Tender Fee 100
EMD Ref. Documents
Exemption Not Available
Document List
39d15ad4-88f9-465e-8cd5-0326dccfe8a9.html
BOQ_300266.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 13, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 20, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

39d15ad4-88f9-465e-8cd5-0326dccfe8a9.html

xls

BOQ_300266.xls

pdf

Tendernotice_1.pdf

TenderDetail
Loading tenders