Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-08-2022 | Corrigendum to extend the dates 16.08.2022 | Date | 23-08-2022 |
| 2 | 01-08-2022 | corrigendum to extend the dates 01.08.2022 | Date | 16-08-2022 |
| 3 | 28-07-2022 | Engineers cost 28.07.2022 | Other | 01-08-2022 |
| Sl. No. | Item Description |
| 1 | Part A : Civil Work |
| 2 | EARTH WORK |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal ofexcavated earth, lead upto 50m and all lift upto 1.5m, disposed earth to be levelled and neatly dressed:All kinds of soil |
| 4 | Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas(exceeding30cmindepth,1.5minwidthaswellas10sqmonplan)including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed: |
| 5 | Oridinary Rock |
| 6 | Hard Rock (Blasting Prohibited) useful material 30 % |
| 7 | Earthworkinexcavationbymechanicalmeans(HydraulicExcavator)/manualmeansin foundation trenchesordrains(notexceeding1.5min width or10sqmonplan)including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soilanddepositingandrefillingofjhiriwithwatering&ramminganddisposalofsurplus excavated soil as directed with in a lead of 50 meter. All kinds of soils. |
| 8 | Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sum on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed with a lead in a 50 meter including stacking of useful material if available. |
| 9 | Oridinary Rock |
| 10 | Hard Rock (Blasting Prohibited) useful material 30 % |
| 11 | Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof in |
| 12 | In all kind of soils. |
| 13 | In Ordinary rock and hard rock. |
| 14 | Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. |
| 15 | SupplyingandFillinginplinthwithriversandunderfloorsincludingwateringramming consolidating and dressing complete including cost of sand |
| 16 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos / Lindane emulsifiable concentrate of 20% |
| 17 | Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRECONSTRUCTIONALAntitermitetreatmentasperIS6313partIIIasamendedfrom time to time and creating a continuous chemical barrier under and around the column pits, walltrenches,basementexcavation,topsurfaceofplinthfilling,junctionofwallandfloor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) |
| 18 | Carriage of earth etc by mechanical transport includeing, loading, unloading and stacking Up to 5 Km |
| 19 | Construction of embankment with approved material obtained from borrow pits with all lifts andleads,transportingtosite,spreading,gradingtorequiredslopeandcompactingby vibratory roller 8-10 Tonne to meet requirement of Table 300-2 including cost of compensation for earth taken from private land with ALL lead As per MoRTH specification Clause No. 305. |
| 20 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 21 | CONCRETE |
| 22 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). |
| 23 | Providing and laying cement concrete including curing, compaction etc. complete in retaining walls,returnwalls,walls(anythickness)includingattachedpilasters,columns,piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering. M15gradeNominalMix.1:2:4(1cement:2coarsesand:4gradedstone aggregate 20mm nominal size). |
| 24 | Providing and laying damp-proof course with cement concrete grade M-15 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as perspecification . 50 mm thick. |
| 25 | REINFORCEDCEMENTCONCRETE |
| 26 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. |
| 27 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level |
| 28 | (a) Walls (any thickness) including attached pilasters, buttresses plinth and string course. |
| 29 | (b) Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor locks,sills,chhajjas,lintel,beam, plinth beam etc. |
| 30 | (c) Columns, pillars, posts and struts etc. |
| 31 | (d) Grid roofing with panel area less than 2.25 Sqm. (contact area to be measured). |
| 32 | Add extra for shuttering in circular work (in respective centering and shuttering items) |
| 33 | Add extra for centering and shuttering work in superstructure above floor five level for each four floor or part thereof . |
| 34 | Addextraforadditionalheightincentring,shutteringwhereeverrequiredwithadequate bracing,proppingetc.includingcostofde-shutteringanddecentringatalllevels,overa heightof3.5m,foreveryadditionalheightof1metreorpartthereof(Planareaistobe measured) |
| 35 | ProvidingandfabricatingreinforcementforR.C.C.workincludingstraightening,cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. : Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 36 | Add extra for reinforcementin superstructure above floor five level for each four flooror part thereof . |
| 37 | Providing and laying in position Ready mix concrete manufactured in fullyautomatic Batching Plant andtransported to site intransit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge . All works upto floor V floorM20 grade Design Mix by using min 400 Kg of cement per cum of concrete |
| 38 | Providing M-25 grade concrete by using min 410 kg of cement per cum instead ofM-20 grade design mix. |
| 39 | Providing M-30 grade concrete by using min 420 kg of cement per cum instead ofM-20 grade design mix. |
| 40 | Add extra for RCC work in superstructure above floor five level for each four flooror part thereof . |
| 41 | Providing and fixing 150 mm wide sheet covering over expansion joints with iron screws as per design to match the colour / shadeofwalltreatment. Aluminum fluted strips 2 mm thick |
| 42 | Providingandfixingexpansion jointboardforbuildingRCCcolumnbeams,walls,slabof Polyethylene foam of density 30 to 35 Kg/m3 of Armour Board.: 40 mm |
| 43 | Supplyingandprovidingoftwocomponentspolysulphidesealantcontainingsolid contents, confirming tostandard specification and approved compatibleprimer, for primingverticalfacespriortoapplicationofpolysulphidesealantincludingall labour charges for sealing of expansion joints after drillmixing of twocomponents sealingcompound.Cleaningandpreparationofexpansionjointusingwirebrush sandpaperingwithemerypaperandfilingwithsuitablemechanicalmeans.The work includes racking and cleaning of joints, sticking, debonding tape on bottom of joint, applying primer on edges, using masking tape on edges, providing of sealant and removal of masking tape immediately after providing sealant in joint.Tojoints in flooring, as per drawing with first layer of poly sulphide sealant in size20mmwidthand10mmdepthoverPEFoamandthenprovidingpolyethylene foambackuprod25mmdiasizeandfinallyprovidinganotherlayerofpoly sulphide sealant in size 20 mm width and 10 mm depth over P.E. back up rod as per application procedure and direction of Engineer-in-charge. |
| 44 | BRICK/ RRSM WORK |
| 45 | Random Rubble stone masonry for with hard stone in Foundation and Plinth in Cement Sand mortar above 30 CM thick wall in:Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 46 | Random Rubble stone masonry with hard stone in Superstructure above Plinth level and upto five levelabove 30cm. thick walls in :Cement Mortar 1:4 ( 1-Cement : 4-Sand). |
| 47 | Brick work with Mechanised autoclaved flyash lime bricks conforming to IS : 12894- 2002 ofclassdesignation100insuperstructureaboveplinthleveluptofloor five level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 48 | Brickworkwith F.P.Sbricksofclassdesignation 7.5in superstructureabove plinth level upto floor five level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 49 | Add extra for brick work in superstructure above floor five level, for each four floors or partthereof. |
| 50 | (a) Quantity in Cum. |
| 51 | (b) Quantity in Sqm. |
| 52 | Providing&Layingautoclaveaeratedblocksmasonrywith150mm/230mm/300mmthick AACBlocksofGrade-IConformingtoIS:2185Part:IIIinsuperstructureaboveplinth level with polymer modified adhesive mortar as per direction of Engineer in Charge. |
| 53 | Half brick masonry with mechanised autoclaved flyash lime bricks conforming to IS: 12894-2002of class designation 100 in Superstructure, above plinth level upto floor fivelevel: Cement mortar 1:4 (1-Cement:4-coarse sand). |
| 54 | Add extra providing and placing in position 2 Nos. ,6mm Ø M.S. bar at every third course of half brick masonry |
| 55 | MARBLE WORK / STONE WORK |
| 56 | ProvidingandfixingGranitestoneslabmirrorpolishedandmachineedgecutinwalls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.: Green/Black |
| 57 | (a) Up to 1500 Cm2 Tiles |
| 58 | (b) 1501 Cm2 to 3600 Cm2 Tiles |
| 59 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls,steps,pillarsetc.laidon abedofneatcementslurryfinishedwith flush pointinginthewhitecementmixedwithpigmenttomatchtheshadeofthetilecomplete (excluding the cost of cement plaster on walls and pillar). |
| 60 | Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. |
| 61 | ExtraforusingMarbleprinted/Graniteshadeordarkshadetilesinsteadofwhite, grey,ivory,fumeredbrown,lightgreen,lightblueandotherlightshadesinglazed tilesandMATfinishedtiles. |
| 62 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming toIS:13755andIS:15622coloursuchaswhite,grey,ivory,fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed withpigment tomatchthe shadeof thetile complete(including thecost of cement mortar bed 1:4). |
| 63 | Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. |
| 64 | ExtraforusingMarbleprinted/Graniteshadeordarkshadetilesinsteadofwhite, grey,ivory,fumeredbrown,lightgreen,lightblueandotherlightshadesinglazed tilesandMATfinishedtiles. |
| 65 | Providingandfixing75 mm wide DecorativeBorderindifferentshadesandin all coloures in glazed tileslaidover12mmthickbedofcementmortar1:3(1 cement:3coarsesand)[email protected] including pointing in white mixed with pigment of matching shade complete. |
| 66 | Extra for providing edge moulding to 15-18mm thick marble/ Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.: Granite Work |
| 67 | Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holesfor pillar taps etc. including rubbing and polishing of cut edges etc. complete |
| 68 | Stone work (machine cut edges) for Wall cladding/ Veneering work up to 10 m heightwith 20 to 30 mm thick Pink Sand stone (Bansi Paharpur) and backing filledwithagroutof12mmthickcementmortar1:3(1cement:3coarsesand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of cramps which shall be paid separately) : Exposed face Machine cut |
| 69 | Providing and fixing Stainless Steel Cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 Coarse sand) including making the necessary chases in stone and holes in walls wherever required |
| 70 | WOOD WORK & PVC WORK |
| 71 | Providing and fixing external grade board solid core single leaf flush door shutters IS:2202(Part-II)1996markedusingPhenolformaldehyderesin ingluebothsideswith approved stainless steel fittings complete as per annexure \"A\": |
| 72 | (a) Decorative Teak veener both side - 35 mm thick shutter |
| 73 | (b) Commercial Veneer both side - 35 mm thick shutter |
| 74 | Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item |
| 75 | Extra for providing vision panel not exceeding 0.1 Sqm in all type of flush doors (cost of glass excluded) (overall area ofdoor shutter to be measured) : |
| 76 | Extra if louvers (not exceeding 0.2 sum) are provided in flush door shutters (overall area of door shutters to be measured).. |
| 77 | Extra for cutting rebate in flush door shutters for making double leaf shutter(Total area of the shutter to be measured). |
| 78 | Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges : Kota stone 25 to 30mm thick. |
| 79 | Providing and fixing wall panelling using soft wood frame of size 50x25mm @600 mm c/c in both directions duly treated with anti-termite treatment making grooves painting of grooves specification and drawing using : 12mm thick Acoustical Board |
| 80 | Providing and fixing 50 mm thick resin bounded glass wool 32 kg/cum density wrapped in julities cloth bag (box type) and held in position using chicken mesh |
| 81 | Providing and fixing Hassian cloth of approved colour and texture over soft wood frame glass wool & fibre glass tissuse paper |
| 82 | Providing and fixing expandable fastners of specified size with necessary plastic sleeves and galvanisedM.S.screwsincludingdrillingholesinmasonrywork/CC/R.C.C.andmaking good etc. complete : 50 mm long |
| 83 | STEEL WORK |
| 84 | Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.: Electric resistance or induction butt welded tubes |
| 85 | ProvidingandfixingT-ironframesfordoors,windowsandventilatorsofmildsteelTee- sections,jointsmitredandweldedwith15x3mmlugs10cmlongembeddedincement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominalsize)orwith woodenplugsandscrewsorrawlplugsandscrewsorwith fixingclipsorwith boltsandnutsasrequireincludingfixingofnecessarybutthingesand screws and applying a priming coat of approved steel primer. |
| 86 | ProvidingandfixingpressedsteeldoorframesconfirmingtoIS4351manufacturedfrom commercialmild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead andifrequiredanglethresholdofmildsteelangleofsection50x25mm,orbasetiesof 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugswithsplitendtailtoeachjambincludingsteelbutthinges2.5mmthickwithmortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steelprimerafterpre-treatmentofthesurfaceincludingfillingwithCC1:2:4(M15grade) complete as directed by Engineer-in-charge : Profile E |
| 87 | Supplyandfixingin cementmortarweldedhandrailingmadeoutofMSroundorsquare bars, flats etc. for staircase or verandah as per design complete in all respect (wooden or PVC hand railing to be paid extra) with priming coat of red oxide. |
| 88 | Extrafor providing D type pipe head as top of hand railing |
| 89 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats or blackpipewith holdfastandfittingscompleteasperdesign anddrawingincludingcutting welding and fabrication with priming coat of red oxide |
| 90 | Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottom rail of T-iron 40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangementsinsideandoutsidestoppers,handlesetc.asperspecificationincludingdimension). |
| 91 | Supplyingandfixingrollingshuttersof approvedmake, madeof 80x 1.25mm.M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for insideandoutsidelockingwithpushandpulloperationcompleteincludingcostofspring hooks, providing and fixing necessary 27.5cm. long wire springs grade No. 2 and M.S. top cover 1.25mm thick for rolling shutters as per design and IS 6248:1979 (Clear openable area to be measured for payment). |
| 92 | Providing and fixing boll bearing for rolling shutters |
| 93 | Extraforprovidingmechanicaldevicechainandcrankoperationforoperatingrolling shutters. : Exceeding 16.80 Sqm in the area. |
| 94 | Providing and fixing steel glazed window frame made out of 80x40 mm hollow sheet section of16gaugethickness,jointmitredwelded andgrindedincludingholdfastofsteellugs 13mm x 3mm and 15 Cm long embedded in C Cblock 15 x 10 x 10 Cm of 1:3:6 nominal concrete and including fixing of pivoted hinges of superior quality, window shutters made out of 50 x 25.0 mm hollow steel section 15 mm paitam of 18 gauge thickness, joint mitred and grinded including 10mm x 10mm square bars welded to framefor paitam fixing float glass 4mm thickpanes with glazing clips and metal sash putty andfixing of shutters frames peg stay, U shape handle 100 mm long, tower bolts 100 mm long of steel powder coated superior quality including fixing and jointing with frame hinges priming coat with steel primer complete in all respect as per direction of Engineer-in –charge |
| 95 | (a) Window fixed. |
| 96 | (b) Window openable. |
| 97 | ExtraforadditionalshutterinpipesectionwindowswithGalvanisedM.S.Wire gauge 14 mesh x 24 gauge |
| 98 | S&FSteelrailingofsteelgrade304madeoftopsideof50mmdiameterof16 gauge & 3 pipes of 19 mm dia of 16 gauge and vertical pipe of 50mm diameter of 16gauge900mmc/ccompleteglossyfinishorpartlyglossyfinishandpartlymat finish. |
| 99 | Providing and fixing of double leaf steel shutterfor cupboard, the frame is made of pressed steelISI section 80x25 mmx1.25 mm thickwith 1.00 mm MS sheet to spot weldedincludingholdfastsof15x3mm,MSoxidizedfittingssuchasbutthinges, slidingdoorsbolts,handles,towerboltsandtwinpegetccomplete including applying priming coat of approved steel primer of red oxide zinc chromate andspray paintinginapprovedshadewithdeco paintofapprovedqualitycompleteasper direction of Engineer In Charge |
| 100 | ROOFING |
| 101 | Providing & fixing calcium silicate ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fix / weather resistant sealed against air and water complete as per drawings, requirements , specifications and as directed by Enginees.: 8 mm thick |
| 102 | Providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS 2095- Part I at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling withdashfastener12.5mmdiax40mmlongwith6mmdiaboltstotheanglehangersof 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board w / weather resistant sealed against air and water complete as per drawings, requirements , specifications the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also includingthecostofmakingopeningsforlightfittings,grills,diffusers,cutoutsmadewith frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting. |
| 103 | Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm andlayingfalseceilingtilesofapprovedtexturein thegridincluding,wherever,required, cutting/making,openingforserviceslikediffusers,grills,lightfittings,fixtures,smoke detectors etc. Main “T” runners to be suspender IGBC scheme. und conforming to IS : 2645. iling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineerin-Charge. |
| 104 | Providing&fixingUVstabilisedfiberglassreinforcedplasticsheetroofinguptoanypitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufacturedoutof2400TEXpanelrovigsincorporatingminimum0.3%Ultra-voilet stabiliserinresinsystemunderapproximately2400psiandhotcured.Theyshallbeof uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. : 5.0 mm thick (Wt.8.4 Kg./Mtr.Sq.) |
| 105 | Extra for corrugated Fiberglass Reinforced Plastic (FRP) (2.5\" /4.2\"/6\") or step down (2.5\"/4.2\"/6\") as specified |
| 106 | Providing and laying integral cement based water proofing treatment including preparation of surfaceasrequiredfortreatmentofroofs,balconies,terracesetcconsistingof following operations.(a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed withproprietarywaterproofingcompoundconformingtoIS.2645overtheRCCslab including cleaning the surface before treatment.(b) Laying cement concrete using broken bricks/brick bats 25 mm to 100mm size with 50% of cementmortar1:4(1cement:4coarsesand)admixedwithproprietarywaterproofing compound conforming to IS : 2645 over 20 mm thick layer of cement mortar of mix 1:4(1 cement :4 coarse sand)admixed with proprietary water proofing compound conforming to IS:2645torequiredslopeandtreatingsimilarlytheadjoiningwallsupto300mmheight including rounding of junctions of walls and slabs.(c)Aftertwodaysofpropercuringapplyinga secondcoat ofcement slurryadmixed with proprietary waterr IGBC scheme. und conforming to IS : 2645. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix1:4 (1 cement :4 coarsesand)admixedwithproprietarywaterproofingcompoundconformingtoIS:2645 and finally finishing the surfacewithtrowel withneatcement slurryand makingof 300x300xmm square(e) The whole terrace so finished shall be flooded with water fora minimum period of two weeks for curing and for final test.All above operations to be done in order and as directed and specified by the Engineer-in-Charge.With average thickness of 120mm and minimumthickness at khurra as65 mm. |
| 107 | Makingkhurras450x450mmwithaverageminimumthickness50mm cementconcrete 1:2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1:3 and onecoat of neat cement, rounding edges and making and finishing the out let complete. |
| 108 | Providinggola75x75mmincementconcrete1:2:4(1cement:2coarsesand:4stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 109 | FLOORING |
| 110 | Cementconcreteflooring1:2:4(1cement:2coarsesand:4gradedstoneaggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. : 40 mm thick with 20 mm thick nominal size aggregate. |
| 111 | Cement plaster in skirting and/dado 18 mm thick with cement mortar 1:3 (1 cement : 3 course sand) finished with a floating coat of neat cement including rounding of junctions with floor |
| 112 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors.: 40 mm wide and 4 mm thick. |
| 113 | Providing&layingChequerredterrazzotilesofapprovedmake22mmthickwithmarble chipsofsizeupto6mm,infloors,jointedwithneatcementslurrymixedwithpigmentto matchtheshadeoftilesincludingrubbingandpolishingcompleteinallrespectasper specification, on 20 mm thick bed of C.M. 1:4 : Medium shade using approximately 50% white cement and 50% ordinary cement. |
| 114 | Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : For area of each slab from 2001 to 5000Sq. Cm : |
| 115 | Kotastoneslabs20mmthickin risersofsteps,skirting,dadoandpillarslaidon12mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete : For area of each slab upto 2001Sqcm |
| 116 | P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. : size 600 mm X 600 mm |
| 117 | Providing and fixing Marble stone flooring table rubbed, 15 -18 mm thick over 20mm (Av.) thick base of CM 1:4 (1 cement : 4 coarse sand) jointingwith whitecement mortar1:2 (1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. |
| 118 | (a) Rajnagar 1st quality/Ageria with light spots. : Up to 1500 Cm2 Tiles |
| 119 | (b) Keseriaji/ Abu Ambaji (Green Marble) : 1501 Cm2 to 3600 Cm2 Tiles |
| 120 | Crazymarblestoneflooring20mmthickmarblestonewithblackorofspecifiedcolour toppingincludingfillingthegapswithcementmarblechipsmixinproportionof4:7(4- Cement:7-White black or white or black marble chips) size from 1 mm to 4 mm by volume and under layer of 25 mm thick cement concrete [1:2:4, graded stone aggregate 12.5 mm nominal size] rubbing and polishing and cement slurry etc. complete : In ordinary cement |
| 121 | Random rubble dry stone Kharanja/ solingunder floor. |
| 122 | FINISHING |
| 123 | Plasteronnewsurfaceonwallsincementsandmortar1:6includingrackingofjointetc. complete fine finished: 12 mm thick. |
| 124 | Plasteronnewsurfaceonwallsincementsandmortar1:4includingrakingofjointsetc. complete fine finish: 20 mm thick. |
| 125 | 6 mm thick cement plaster to ceiling of mix 1:3 (1cement : 3-fine sand) |
| 126 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. |
| 127 | Finishing with neat cement (Punning). |
| 128 | Making grooves as per design in plaster 10mm to 20mm wide. |
| 129 | Extra for making Ornamental design like Kangooras Gola etc. as per Jaipur practice in 12 mm cement plaster |
| 130 | Extra for making Ornamental design like Kangooras Gola etc. as per Jaipur practice in 20 mm cement plaster |
| 131 | 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand) : |
| 132 | (a) Flush band. |
| 133 | (b) Sunkband. |
| 134 | (c) Mouldedband. |
| 135 | Plaster on new surface on wall in cement sand mortar 1:3 including raking of joints etc. complete fine finish : 12 mm thick. |
| 136 | Extraforplasteringexteriorwallsofheightmorethan10mfromgroundlevelforevery additional height of 3 m or part thereof. : External Plaster |
| 137 | Providing and Fixing Chiken wire mesh at the joint of masonry members/ R.C.C. Members with Nails complete in all respect. |
| 138 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: New work (two or more coats) over and including scrapping andpriming coat with cement primer. |
| 139 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Newwork(Twoormorecoats) includingprepartionofbasewithprimer,putty,lippyetc complete in all respect. |
| 140 | Providingandapplyingwhitecementbasedputtyoverplasteredsurfacetopreparethe surface even and smooth complete |
| 141 | Paintingwith syntheticenamelpaintofapprovedbrandandmanufactureto givean even shade : Two or more coats on new work |
| 142 | French sprit polishing Two or more coats on new work including a coat of wood filler. |
| 143 | Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. Newwork([email protected]/10sqmoverandincludingbasecoatof water proofing cement paint applied @ 2.20 kg/ 10 sqm ). |
| 144 | Finishingwallswithtexturedexteriorpaintofrequiredshadeasperapprovedcolour completeaspermanufacturersspecificationsincludingprimercoatandprotectingcoat including scaffolding and safety provision - Trowel Finish av. thickness 1000 to 1200 microns. |
| 145 | DISMANTLING AND DEMOLISHING WORK |
| 146 | DemolishingR.C.C.workmanually/bymechanicalmeansincludingstacking ofsteelbars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge. |
| 147 | Demolishingbrickworkmanually/bymechanicalmeansincludingstackingofserviceable materialanddisposalofunserviceablematerialwithin50metresleadasperdirectionof Engineer-in-charge. : In Cement mortar. |
| 148 | Dismantlingbricktilescoveringin terracingincludingstackingofserviceablematerialand disposal of unserviceable material within 50 meters lead. |
| 149 | Demolishingmudphuska/Limedhar/Kharanjain terracinganddisposalofunserviceable material within 50 meters lead. |
| 150 | WATER PROOFING |
| 151 | Providing & applyingone coatof UVresistant polymercement basedwaterproofing slurry coating of approved make and quality on concrete or plastered surface as perspecifications including preparation of surface by cleaning brushing and dust removing, filling of cracks and making the surface leak proof by mixing one part of chemicalwith 2 parts of cement and 2 partsofwater(coveringarea 1.86Sq.M/Kg ofchemical) includingcost ofcement, labour, tools & plant, scaffolding if necessary etc., complete as directed by Engineer in Charge.Note: Undulations/cracks found on the surface should be rectified with Cement Motor before application and the same will be paid under relavent items. |
| 152 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours.b)Secondlayerofslurry [email protected]/sqmmixedwithwaterproffingcement compound @ 0.126 kg/sqm Thislayer willbe allowedto aircure for 4 hoursfollowed by water curing for 48 hours.The rates includes preparation of surface treatment & sealing of all joints ,corners,junction with polymer mixed slurry.Note : Rendering/ Plastering as protective layer, if required will be paid seperately) |
| 153 | ALLUMINIUM & PVC WORKS |
| 154 | Providingandfixing aluminumwork fordoors,windows,ventilatorsandpartitionwith extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawlplugs and screws orwith fixing clips, or with expansion hold fasteners including necessary filling up of gap. at junctions, at top,bottomandsideswithrequiredPVC/neoprenefeltetc.Aluminiumsectionshallbe smooth,rustfree,straight,miteredandjointedmechanicallywhereverrequiredincluding cleat angle Aluminium snap beading for glazing /paneling, C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc., all complete as per architectural drawings and thedirections of Engineer- in – charge. (Glazing and paneling to be paid for separately). |
| 155 | (a) For fixed portion |
| 156 | Polyester Powder coating aluminum (minimum thickness of powder coating 50 micron) |
| 157 | (b) Forshuttersbuiltupstandardtubularsectionsofopenabledoors,windows&ventilators includingproviding&fixinghinges/rollersetc.andmakingprovisionforfixingoffittings wherever required (lockes shall be paid for separately). |
| 158 | Polyester Powder coating aluminum (minimum thickness of powder coating 50 micron) |
| 159 | (c) Extra for shutters of slidingaluminum windows |
| 160 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. withPVS/neoprenegasketetc.completeasperthearchitecturaldrawingsandthe directionsofengineer-in-charge.(Costofaluminiumsnapbeadingshallbepaidinbasic item.) : With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm) |
| 161 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S.With stainless steel cover plate |
| 162 | Providingandfixingexpandedgrillmadeofaluminumasperdesignanddrawinghaving members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium sec (as per drawing) at the ends and middlejointsr+C395espectivelycompleteinallrespectasperdirectionofengineerin charge.: Polyester Powder coating aluminum ( minimum thickness of powder coating 50 micron) |
| 163 | Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 164 | S & f fixed wire gauge of stainless steelof 14meshx24gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws at not exceeding 150 mm distance at all heights with all lead and lift with scafolding. |
| 165 | Providing and fixing Structural glazing work with toughened glass of 6mm thick and reflective colour as approved in dark shade like Blue/Dark Blue etc. with frame work of curtain section 65x60mm (Weight 1.64 kg/m min.) made of aluminium with chrome plating. Internal frame work will also be of curtain section 65x60mm of chrome plated aluminium section with20x20mm aluminium tube section andstructural spacer made of rubber. The aluminium frame work size as per instruction of Engineer-in-charge and including openable panels with all necesary sections and fitting.The work include silicon structural adhesive for completegripping of glass with framing members and silicon weather seal sealant to prevent moisture/water through joints. Glass will be fixed in plumb and with uniform spacing of 10-12mm wide duly filled with silicon weather seal sealant. Thework includes all labour,scaffolding , structural aluminium work, toughened glasses,silicon weather seal sealant, silicon structural adhesive structrucal spacer, all accessoreis like handles, peg stays, M-15 grade cement concrete for fixingholdfast .(Face area of glass shall be measured) |
| 166 | ROAD WORK |
| 167 | Constructionofsubgradeandearthenshoulderswithapprovedmaterialobtainedfrom borrow pits with all lifts and leads, transporting to site, spreading, grading to require slope andcompactedbyvibratoryroller8-10Tonneto meetrequirement ofTable 300-2as per MoRTH specification Clause No. 305. |
| 168 | Providingandlayinggranularsub-basematerialhavingP.I.notmorethan6including spreading in layers not exceeding 150 mm compacted thicknessand consolidation by 8-10 tonne power rollerto required camber and grade including cost of water and hire charges of machineryincludingT&Pwithalllead(Compactedthicknesstobemeasured).asper MoRTH specification table 400-1, 400-2, : For grading-I with CBR value not less than 30. To attain 100% proctor density. |
| 169 | Providing, laying, spreading and compactingstone aggregate forWet Mix Macadam (as per table 400-10 and 400-11) specification including premixing the material with water to OMC in wet mix plant as per approved design mix, carriage of mixed material by Tipper to site, laying inuniformlayerswithmotorgrader/FrontendLoader/paverfinisher,insubbase/base course on a wellpreparedunder baseand compactingwith vibratoryroller toachieve the desireddensityincludinglighting,guarding,barricadingandmaintenanceofdiversion etc. (MoRTH specification : Clause 406) by mechanical means with lead up to 20 Km. |
| 170 | Providingandapplyingprimercoatoverpreparedsurfaceorgranularbasewithbitumen emulsion SS-1 as per IS: 8887 & manufacturer’s specifications @ 6 kg /10 Sqm with a self propelled or towed bitumen pressure sprayer equipped for spraying the material uniformly at specifiedratesandtemperaturesasperMoRTHspecificationCI502&112(Including cleaning of road surface ) |
| 171 | Providing and applying tack coat on the prepared surface, withbitumen emulsion RS-1 as per IS : 8887 & manufacturer’s specifications @ 2 kg /10sqm. With a self propelled or towed bitumen pressure sprayer equipped for spraying the material uniformly at specified rates and temperatures as per MoRTH specification Clause 503 & 112 ( Including cleaning of bituminous road surface ) |
| 172 | Providing and laying Dense Bituminous Macadam on prepared surface with specified graded crushedaggregatesaspertable510anddesignmixforbase/bindercourseincluding loading of material with Front end loader, heating of binder (including cost of anti-stripping compound wherever required) aggregate and filler in hot mix plant 40-60 TPH, transporting the mixed material by tippers and laying with sensor paver finisher as per clause 507.3.5 to the required leveland grade rolling by self propelled power rollers and vibratoryrollers or pneumatic tyred roller 150-250KN. TP=0.7MPa to achieve the desired density (approved by the department) but excluding cost of primer/tack coat. [MoRTH Specification : Clause 507 & 112] : GradingII(19mmnominalsize)-Bitumen @4.0- 4.5% ofmix (60/70grade) VG30 & thickness 50 - 75 mm with lead of mix material 20km |
| 173 | Providingandlayingbituminousconcreteasperdesignmixonprepared surfacewith specified graded stone as per table 500-18 for wearing course including loading of aggregate with Frontendloaderandhotmixingofbinder(includingcostofanti-stripping compound, whereverrequired)and3%cementfillerwithaggregatesinhotmixplant40-60TPH Transporting the mix material with tipper and laying with sensor paver finisher (as per clause 507.3.5) to the required level, grades and rolling with vibratory compactorand pneumatic tyredroller150-250KN,TP=0.7Mpa,toachievethedesireddensity(approvedbythe department) excluding cost of primer/tack coat (MoRTH Specification : Clause -509 & 112) : Grading II (13 mm nominal size) - Bitumen @ 5 % of mix& thickness 30 - 45 mm with lead of mix material 20km using 60/70 grade VG 30 |
| 174 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cementinpositiontotherequiredline,levelandcurvaturejointedwithcement mortar1:3(1cement:3coarsesand)includingmakingjointswithwithout grooves(thicknessofjointsexceptatsharpcurveshallnottomorethan5mm) includingmakingdrainageopeningwhereverrequiredcompleteincludingpainting etc.asperdirectionof Engineer-in-charge(lengthof finished kerb edging shallbe measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in- charge). |
| 175 | Providingandlayingof paverblockasperIS15658:2006(Indianstandardfor precast concreteblockforpaving-specification)andIRC:SP:63-2004(guidelines for the use of interlocking concrete block pavement) M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily trafficof150-450commercial vehiclesexceeding30KN ladenweight, oran equivalent of 0.5to2.0MSAfora designlifeof20years.)likecitystreets,small andmediummarketroads,lowvolumeroads,utilitycutsonarterialroads,etc Category‘B’ Denated only two side like I,Z,T shape etc. as per IRC SP63:2004 |
| 176 | Add extra over item No. 11.38, A to C if reflective paver block, manufactured with wet cast vibration system in two layers is used. |
| 177 | Add extra over rates of item No. 11.38, A to C if colored paverblocks are used |
| 178 | HORTICUL TURE WORKS |
| 179 | Supply of dry manure including loading unloading,transportation & stacking at site.- Farm yard manure(organic) |
| 180 | Supply&Stackinggoodearthatsitecompleteincludingloadingunloading& transporation etc. |
| 181 | Layingoflawnsincludingploughinglevelingbreakingofclodsmanuringandremovalof stones etc. (cost of manure or extra good earth to be paid separately )maintenance of lawn for 30 days or more till the grass forms a thick lawns free from weeds and fit for moving in the duration of planting if lawn die some where the contractor will replant it at his own cost : in rows 7.5 cm apart in either direction |
| 182 | Supply & Planting of shady plants ( Neem. Peepal, Goolar, Jamun, Imli or other specified) along road side including the following activities:- |
| 183 | (a) Preparation of soil including cleaning & removing of unwanted shrubs removal of stones & garbage. |
| 184 | (b) Supply of plant at site of two years of age & height more than 1.50 Mtr. |
| 185 | (c) Supply of dry manure(Farm yard manure organic) |
| 186 | (d) Supply of Insecticides. |
| 187 | (e) Diggingofpitssize60x60x60cms.Includingremovalofstones.Manuringapplicationof insecticides & watering at least 1.5 Liter per plant after planting |
| 188 | (f) Watering to plants |
| 189 | (g)Maintance of plants by the contractor including pits, preparation of Thavala Hoeing weeding etc & application of insecticiedes etc. & security. If the plant die during maintence contractor has to rplace same heingh plant at his own cost. |
| 190 | Supply&Pantingofornamentalplants(Kachnar,Amaltas,Gulmohar,Arjun,Kala,Siris, Jacranda etc. or other specified) along road side including the following activities :- |
| 191 | (a) Preparation of soil including cleaning & removing of unwanted shrubs removal of stones & garbage |
| 192 | (b) Supply of plant at site of two years of age & height more than 1.50 Mtr. |
| 193 | (c) Supply of dry manure( Farm yard manure organic) |
| 194 | (d) Supply of Insecticides |
| 195 | (e) Diggingofpitssize60x60x60cms.Includingremovalofstones.Manuringapplicationof insecticides & watering at least 1.5 liter per plant after planting. |
| 196 | (f)Waterring to Plants. |
| 197 | (g) Maintenanceofplantsbythecontractorincludingpits.PreparationofThavalaHoeing weeding etc. & application of insecticides etc. & security. If the plant die during maintencance contractor has to replace same height plant at his own cost. |
| 198 | Planting & Maintenance of shrubs. |
| 199 | (a) Planting of shrubs in central verge |
| 200 | (b) Preparation of soil including cleaning & removing of unwanted shrubs removal of stones & garbage. |
| 201 | (c) Supply of plant at site like Bouganvillia & Kaner. |
| 202 | (d) Supply of dry manure( Farm yard manure organic) |
| 203 | (e) Supply of Insecticides |
| 204 | (f) Diggingofpitssize60x60x60cms.Includingremovalofstones.Manuringapplicationof insecticides & watering at least 1.5 liter per plant after planting. |
| 205 | (g)Waterring to Plants. |
| 206 | (h) Maintenanceofplantsbythecontractorincludingpits.PreparationofThavalaHoeing weeding etc. & application of insecticides etc. & security. If the plant die during maintencance contractor has to replace same height plant at his own cost. |
| 207 | Furniture |
| 208 | 3 Seater fix seating arrangements This unit has to be mounted in a lecture theatre of step ladder type with each ladder of approx 1080 mm. The units have to aligned at side by side eith passage in between or as per layout approved by engineer in charge/ client. 3-seater desk size- Top : 1800W x 375 to 400D x 750H, Intermediate partition for storage : 1800W x 200D. The Desk top shall be made with 25 mm thick ply with 1 mm laminate of approved shade on both sides and 2 mm thick edge taping of matching colour on all edges. There shall be MS perforated modesty panels of 1.2 mm thick. Understructure consists of MS oval tube 70x30x2mm, rectangular pipe 75x30x2.5mm, 25x10x1.6mm, epoxy powder coated of 40-50 microns. All tube ends to be provided with high density caps. All corners to have 10 mm radius. 3 Seater seat size 1800W x 350D x 450H. Seat shall be 18 mm thick ply with 1 mm laminate of approved shade on both sides and 2 mm thick edge taping of matching colour on all edges and seat fixed to under structure with pop-up rivets. Understructure consists of MS oval tube 70x30x2mm, rectangular pipe 75x10x2.5mm, 25x10x1.6mm thick, 25x25x2mm, 55x35x2mm with base plate of 2 mm thick sheet grouted on floor, epoxy powder coated of 40-50 microns. All tube ends to be provided with high density. |
| 209 | Part B : Sanitary Work |
| 210 | SANITARY FIXTURES |
| 211 | P & E Indian type white glazed vitreous .china 1st quality W:C. orissa pan (IS:2556 Mark) with100 mm vitreous china P or S trap including cutting and making good the wall and floor : |
| 212 | size 580x440 mm |
| 213 | P & F European type white glazed vitreouschina 1st quality Double symphonic W.C. (IS:2556 Mark) with P or S trap including cutting and making good the wall and floor. |
| 214 | P & F WVC Wash basin (1st quality\" IS:2556Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:X934Mark) &32mmC.P.brasswastecouplingofapprovedmake25mmG.l. waste pipe complete including cutting & making good the wall : |
| 215 | size 550x400 mm |
| 216 | Size 630 mm x 500 mm dia for counter top |
| 217 | P&F W.V.C. Urinal Partition plate of approvedstandard make of size 630x315 mm including making good the wall. |
| 218 | P & F Marble Urinal Partition slab both sides polished of approved design cut from marble size 900x600mm. |
| 219 | Makrana II Quality marble having light spots. |
| 220 | P&F I quality WVC Urinal (IS :2556 mark) with 25 mm dia G.I. waste pipe, dome waste couplings\",; concealed iron brackets or screwsetc. complete. |
| 221 | Flat Back (large)half stall Urinal size 610x400x80 mm |
| 222 | P & F kitchen & Lab Sink of approved make with C.I. brackets duly painted, 40 mmC.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up to floor level complete including cutting and making good the wall & floor : |
| 223 | WVC lab sink (IS : 2556 mark) size 530x430x180mm. |
| 224 | WVC lab sink (IS : 2556 mark) size 450x300x150mm. |
| 225 | Providing and fixing 1.0mm thick Stainless Steel AISI 304 & IS 13983 kitchen sink of approved make (Nirali, Neel - kanth, Jaina, Faber Castell) with large waste coupling. |
| 226 | Overall size (45x20x8 inches ) and bowl size: 20x16x8 inches (With drain board) |
| 227 | Overall size (24x18x8 inches ) and bowl size: 20x16x8 inches (Without drain board) |
| 228 | P & F Chromium plated Swan-neck Laboratory Cock of approved quality / make: |
| 229 | One Way. |
| 230 | Two Way. |
| 231 | Providing & Fixing P.V.C. waste pipe with all fittings complete. |
| 232 | PVC with C.P. Nut 32mm dia |
| 233 | PVC with C.P. Nut 40mm dia |
| 234 | P & F looking mirrors with PVC frame of approved (Atul, Modi Guard, Saint Gobain orequiavalent. |
| 235 | Size 500x400mm |
| 236 | Providing and fixing Bottle Trap of of approvedmake |
| 237 | C.P. Brass 32 mm |
| 238 | C.P. Brass 40 mm |
| 239 | P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Geyser etc. |
| 240 | C.P. Inlet connection 15 mm Brass (1S:8931 marked). |
| 241 | P & F Low level Flushing Cistern of 10litrescapacity (IS:2556 mark) of approved makewithcompletefittingsC.I.bracketsdulypainted,brassballcockwithball, (IS:1703 mark) complete including cutting and making good the wall : |
| 242 | PVC with PVC bend as per IS : 7231 |
| 243 | WVC for symphonic EWC. |
| 244 | P & F C.P. brass Urinal Flush pipe set complete with flanged brackets of. Approved make. |
| 245 | For I Urinals. |
| 246 | P & F Extension pipe for bib cocks of approved quality /make: |
| 247 | C.P Brass heavy & superior quality 150 x 15mm |
| 248 | P&F Jet spray for water closet with C.P. copper tube flange of approved make |
| 249 | P & F Toilet Shelf of approved quality/make: |
| 250 | Acrylic shelf on C.P. brass casted brackets & guard rail of commander or equivalentmake size 550 X 125 mm |
| 251 | Providing and fixingSuperior quality (Jaguar Contiental ) CP Brassfittings complete as per direction of EI |
| 252 | Pillar Cock 15 mm nominal size |
| 253 | Swan neck pillar cock 15 mm nominal size |
| 254 | Bib Cock with long thread 15 mm nominal size |
| 255 | Long body Bib Cock 15 mm nominal size |
| 256 | Two way Bib Cock 15 mm nominal size |
| 257 | Angular stop cock with long thread 15 mm nominal size |
| 258 | Sink cock with swinging casted spout (table mounted ) 15 mm nominal size |
| 259 | Central hole basin mixer |
| 260 | Wall mixer 3 in 1 system with provision of tetephonic bath shower with bend pipe |
| 261 | 600 mm long towel rail |
| 262 | Revolving type towel ring |
| 263 | Soap dish |
| 264 | Double coat hook |
| 265 | 190 mm rain shower |
| 266 | Paper holder |
| 267 | P & F C.P. Health Faucet with 1Mtr. Long Tube & Hook of approved make and heavy as per direction of Enginner-inCharge |
| 268 | P & F water closet Seat Covers with brass hinges complete : |
| 269 | Solid PVC (IS 2548 marked) grade-I White for EWC. |
| 270 | P & F Mixing Range (15 mm) |
| 271 | C.P. One hole/close hole basin mixer with casted spout. |
| 272 | P & F Divertorsof superior quality and approved make: |
| 273 | C.P. brass Tip-tone divertor bath spout with mixing valve. |
| 274 | SupplyandInstallationofGrabBarS,type-304,18-gauge(1mm)stainlesssteel tubing with satin-finish.1-1/2\"(25.4mm) outside diameter. Concealed Mounting Flanges—18-8S,type-304,stainlesssteelplate;endflangeswithtwoholesfor attachmenttowall.SnapFlangeCovers—18-8S,type-304,22-gauge(0.8mm) drawnstainlesssteelwithsatin-finish.Eachcoversnapsovermountingflangeto conceal mounting screws. |
| 275 | SupplyandInstallationofSwingGrabBar18-8S,type-304,18-gauge(1mm) stainlesssteeltubingwithsatin-finish.1–1/4(25mm)outsidediameter.Endsare heliarc welded to flanges.Backplate - 18-8S, type-304,3/16\" (5mm)thick, satin-finishstainlesssteel with four screw holes for attachment to wall. |
| 276 | SOIL, WASTE,VENT AND RAIN WATER PIPES |
| 277 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make |
| 278 | 110 mm dia |
| 279 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make |
| 280 | Coupler 110mm dia |
| 281 | Bend 87.5 Dg. 110mm dia |
| 282 | Bend 45 Dg. 110mm dia |
| 283 | Door Bend 87.5 Dg. 110mm dia |
| 284 | Double \"Y\" 110mm dia |
| 285 | Socket Plug 110mm dia |
| 286 | Pipe Clip 110mm dia |
| 287 | W.C. Connector 110mm dia |
| 288 | Single Tee 110mm dia |
| 289 | Multi floor trap 110mm dia |
| 290 | Nahni Trap with Jali 4” 110mm dia |
| 291 | Vent Cowel 110mm dia |
| 292 | P&FrigidPVCPipe(IS:4985mark)classII(4Kg./Cm.)approvedquality/make including joining the pipe with solvent cement rubber ring and lubricant |
| 293 | 110mm dia |
| 294 | 160 mm dia |
| 295 | P&FrigidPVCpipefittings(IS:4985mark)ofapprovedquality/makeincluding joining the pipe with solvent cement rubber ring and lubricant: |
| 296 | 110mm dia |
| 297 | Coupler(socket) |
| 298 | Door Tee |
| 299 | Bend 45 |
| 300 | Door Bend (top side) |
| 301 | Vent Cowel |
| 302 | Pipe clip |
| 303 | WC connector with lipring |
| 304 | WC connector bent type |
| 305 | Multi Floor Trap |
| 306 | Height raiser |
| 307 | Top tile & straine |
| 308 | P-Trap |
| 309 | Gully Trap |
| 310 | 160 mm dia |
| 311 | Coupler(socket) |
| 312 | Door Tee |
| 313 | Bend 45 |
| 314 | Door Bend (top side) |
| 315 | Vent Cowel |
| 316 | Pipe clip |
| 317 | Providing and fixing Grating of approved quality/make: |
| 318 | (-do-) Square 150 x 150 x 8mm. (Anti Cockroach) |
| 319 | Painting (two or more coats) on rain water soil, waste and vent pipes and fitting with blackanticorrosivebitumastic paintofapprovedbrandandmanufactureoverand includinga priming coat of ready mixed zinc chromate yellow primer on new work: |
| 320 | 100 mm dia. pipes. |
| 321 | 150 mm dia. pipes. |
| 322 | ProvidingandlayingLaboratory /hospitalEffluentwastepipeandfittingofhigh densitypolyethelene(HDPE),CLASS-PE80,pressureratingPN-6,conformingtoIS:4427,electricfusionjoints/flangedjoints,fittingswhichincludes bends,,junctions,cowls,offsets,access pieces.etc. complete including jointing. |
| 323 | 50 mm dia |
| 324 | 90 mm dia |
| 325 | 110 mm dia |
| 326 | WATER SUPPLY (Internal & External) |
| 327 | ProvidingandfixingChlorinatedPolyvinyl Chloride(CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittingswithonestepCPVCsolventcementandtestingofjointscompleteasper direction of Engineer in Charge. ( INTERNAL WORK - EXPOSED ON WALL) |
| 328 | 15 mm nominal outer dia Pipes |
| 329 | 20 mm nominal outer dia Pipes |
| 330 | 25 mm nominal outer dia Pipes |
| 331 | 32 mm nominal outer dia Pipes |
| 332 | 40 mm nominal outer dia Pipes |
| 333 | 50 mm nominal outer dia Pipes |
| 334 | ProvidingandfixingChlorinatedPolyvenylChloride(CPVC)pipeshaving thermal stability for hot & cold water supply including allCPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.0 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. |
| 335 | Concealed work including cutting chases and making good the walls etc. |
| 336 | 15 mm nominal outer dia pipes |
| 337 | 20 mm nominal outer dia pipes |
| 338 | 25 mm nominal outer dia pipes |
| 339 | 32 mm nominal outer dia pipes |
| 340 | ProvidingandfixingChlorinatedPolyvinyl Chloride(CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 341 | External Works |
| 342 | 32 mm nominal outer dia pipes |
| 343 | 40 mm nominal outer dia pipes |
| 344 | 50 mm nominalouter dia Pipes |
| 345 | P & F Full-way valve (IS:778 Mark) or wheel valve of approved make : |
| 346 | 25mm dia, nominal bore |
| 347 | 32 mm dia, nominal bore |
| 348 | 40 mm dia, nominal bore |
| 349 | 50 mm dia, nominal bore |
| 350 | P&FGun-metalNon-returnValveorCheckvalve(IS:Make)ofapprovedmake, superior quality : |
| 351 | 25 mm nominal bore. |
| 352 | Horizontal : |
| 353 | 40 mm nominal bore. |
| 354 | Horizontal : |
| 355 | 50 nominal bore (vertical) |
| 356 | 50 nominal bore (Horizontal) |
| 357 | 80 mm nominal bore |
| 358 | P & F Stop cock (IS:8931 Mark) superior quality & of approved make |
| 359 | Brass 400 gm. 15 mm nominal bore |
| 360 | P&FPVCStorageTank(IS:12701markedindicatingtheBISlicenseNo.)of approved makewithcover, 25mmdia1 M long. G.I.over-flow pipe& 25Cm: long washoutpipewith:\"plug\"\";&socket,includingmakingconnectionetc.completeof approved design. |
| 361 | 500 litres capacity. |
| 362 | 1000 litres capacity. |
| 363 | 5000 litres capacity. |
| 364 | P & F Water meter IS:779 mark) of approved make: |
| 365 | 25 mm dia. |
| 366 | P & F Ball Cock (IS:1703 Mark) with Rod & P.V.C. Ball complete : |
| 367 | Brass wt. 1000 gm, 25 mm |
| 368 | (-do-) wt1000 gm, 32mm |
| 369 | Brass wt1200 gm, 40 mm. |
| 370 | Brass wt2000 gm, 50 mm. |
| 371 | Making connection of G.I. distribution branch with G.I. main including all fitting. |
| 372 | Beyond 25 mm & up to 100 mm dia. |
| 373 | P & F 15 mm. Dia Connection pipe of approved quality/make: |
| 374 | PVC pipe with C.P. Brass nuts up to length 450 mm. |
| 375 | Constructionof chamber in all typeof soil with300 mmthick masonry in Cm1:6 m 100mm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished withfloatingneatcement,50mmthickM-15gradeC.C.flooring,earthworketc. complete as per design including disposal of surplus earth within a lead of 50 mtr. |
| 376 | Inside size 300x300mm depth upto 0.5m cement concrete cover with frame |
| 377 | Inside size 600x450mm depth upto 0.5m cement concrete cover with frame |
| 378 | -do- depth upto 0.5mtr to 1.0mtr |
| 379 | SITC of self contained drinking water cooler with energy efficienthermeticsealed typecompressor,noncFCrefrigerantsuitableforoperationon230v/LpH/50H2ac supply, Full stainlesssteel [S30a)body andtank, stainlesssteel water tray, minimum twonosfaucetsandsuitabledrainagesystemcompleteinallrespectwith300mm heightMSfabricatedandpaintedplateform.completeinallrespectofthefollowing capacity |
| 380 | Cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs |
| 381 | Cooling capacity 80 Ltr./Hr. and storage capacity 120 Ltrs |
| 382 | SITCofROwatersystemwithFiltrationstage=Particilatefilter-Membranelife enhancer filter - sediment filter - Pre carbon filter -RO Membrane filter - Post carbon filter, Input power Rating - 230 v AC , 50 HZ, Percentage of Rejection TDS - 9oo/o or betterhavingfollowingfeatures[a)DoublepurificationbyROwithESSorlatest technologywithTDSindicator.[b)SpinweldedROMembraneHousingtoprevent tempering.[cJPushfitcomponentsforleakproofperformance[dJFullyautomatic operationwithautostartandautooff.(e)SS/ABSconstructionforcorrosionfree lifespan. (f Equally suitable for water from all bore wells, overhead storage tanks, water tankers and even municipal taps.[g)R0 Membrane Flushing - Auto Flush @ Every Start, Every Stop and every OneHour of working for one minute. complete in all respect with followins capacity |
| 383 | Purification capacity- 50 LPH, Duty Cycle 270-500 liters/day |
| 384 | Purification capacity- 25 LPH, Duty Cycle 170-250 liters/day |
| 385 | SITCofreverseOsmosiswaterPurificationsystem[R0system)compatiblefor water cooler with ABS construction fully automaticoperation with auto start and auto off. capacity, equipped with standard Filtration stage / cartridge [sediment filter , Activatedcarbonfilter,UF,sediment,filingCompositeR0MebraneJ,Inputpower supply 100-250 VAC 1 Ph. System Voltage 24V DC,percentage reduction in TDS 90% orbetter.Thejobincludesinstallationatsitewithexistingwatersupplylinewith required piping accessories etc. The contractor shall provide one year warranty with quarterly service (and also as & when required) of above RO system during warranty period including required consumable items. |
| 386 | Production capacity- 15 LPH, Water storase capacity 8 ltr |
| 387 | P&Fof4starratedverticalstoragewaterheaterwithoutercasingmadeof M.S.sheet finished with anti-corrosive powder coating,inner tank made of pure electrolytic copper/stainless steel / SPHP, Tubular copper sheathed and Nickel plated heatingelement/twinceremiccartridgeheatingelement,stemtypethermostatand thermal cut out,Dual indicating lamps for power supply and thermostat,PUF insulation, Pressurerelasevalve,fusibleplugetc.asrequiredheldinpositionwith4no.rack bolts,duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and16A/25Athreepinplugtop,includingmakinginlet,outletheavygaugeC.P./ Flexible alloy connection,testing etc. as required. Group-1) |
| 388 | 15 Litre Capacity |
| 389 | 25 Litre Capacity |
| 390 | 35 litre capacity |
| 391 | Supply and installation of Premium quality sluice valve 100mm dia including all fittings as per approved by Engineer in charge |
| 392 | P & F Foot valve of superior quality and approved make with fittings : |
| 393 | CI 50 mm |
| 394 | CI 65 mm |
| 395 | CI 80 mm |
| 396 | S&F RCC Manholes covers with frame of approved make (Light duty) |
| 397 | Size 500mm dia (double seal) |
| 398 | Size 600x450mm |
| 399 | Providing Laying Jointing DI Pipe (Ductile iron pipe) of 100 mm dia ISI marked K-7 grade as per IS : 5329-2000 with internal cement mortar lining for potable water with rubber ring (EPDM/ SBR) Joints per IS : 5382-1985 complete including Hydraulic testing & commissioning as per Technical Specification. |
| 400 | Providing Laying Jointing DI Pipe (Ductile iron pipe) of 150 mm dia ISI marked K-7 grade as per IS : 5329-2000 with internal cement mortar lining for potable water with rubber ring (EPDM/ SBR) Joints per IS : 5382-1985 complete including Hydraulic testing & commissioning as per Technical Specification. |
| 401 | SEWARAGE & DRAINAGE |
| 402 | Providing & Laying C.C.1:5:10 (Stone aggregate40 mm nominalsize)upto haunches of S.W. pipes including 150 mm thick bed concrete (Width W=Dia of pipe in Cm+40Cm.) concrete width to be reduced from width W at center of pipe to \"0\" at top of pipe (Excluding cost of pipe). |
| 403 | 150mm dia S.W. Pipe. |
| 404 | 200mm dia S.W. Pipe. |
| 405 | 250mm dia S.W. Pipe. |
| 406 | 300mm dia S.W. Pipe. |
| 407 | 400 dia S.W. Pipe. |
| 408 | P & F Square-mouth gully trap `A` grade (IS :marked) of approved make complete withC.I.grating,frame&CovermasonarychamberinC.M.1:6,100mmthickC.C. 1:5:10 base concrete, 40mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type. |
| 409 | Trap size 150 X 100mm, ferrow cement cover with frame, each internal chamber size300X300mm. |
| 410 | Providing, Laying & Jointing R.C.C. class NP-2 Non-Pressure pipes (IS : 458mark) of approved make with collars, jointed with C.M. 1:2 or having Spigot and socket ends with flexible rubber rings joint including testing of joints etc. complete : |
| 411 | 150mm dia Internal. |
| 412 | 200mm dia Internal. |
| 413 | 250mm dia Internal. |
| 414 | 300mm dia Internal. |
| 415 | 450mm dia internal |
| 416 | Constructionofmanholeinalltypeofsoilinnersize90X60Cm.300mmthick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5 10 in foundation, 20 mm thick inside plaster in CM 1:6, finishedwith floatingneat cement,50mmthickM-15gradeC.C. flooring,making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C.flooring , cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead. |
| 417 | Depth upto 0.5mtr |
| 418 | Add extra over item 3.20.1 for every additional 0.10 mtr depth above 0.5 m depth. |
| 419 | Construction of Man hole, in all types of soil inner size 1.5 x 1.2 M, with, 450mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M-15 gradeC.C. flooring making channels, 80 mm thick stone slab covering with 40 mm thick M-15 grade C.C.flooring, cement cover with frame of 450mm dia, earthwork etc. complete including disposal of surplus earth within 50 mtr. lead as per design : |
| 420 | Depth upto 1.5mtr |
| 421 | Add extra over item 3.21.1 for every addl. 0.10mtr depth above 1.5m depth. |
| 422 | Constructionof chamber in all typeof soil with300 mmthick masonry in Cm1:6 m 100mm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished withfloatingneatcement,50mmthickM-15gradeC.C.flooring,earthworketc. complete as per design including disposal of surplus earth within a lead of 50 mtr. |
| 423 | Inside size 450 x 450mm upto depth of 0.5m Cement concrete cover with frame |
| 424 | Inside depth upto 0.5mtr to 1.0mtr-do- |
| 425 | ConstructionofOpenSurfaceDrainwith112mmthickbrickmasonaryinCM 1:4, 110mm thick base concrete 1:5:10, 37mm thick M-15 grade C.C. flooring, 12 mm 1:4 cement plaster on all exposed face of walls including top surface excavation & disposal of earth complete as per approved design/drawing: |
| 426 | 250mm drain 300mm av. Depth |
| 427 | P&F M.S. foot rests in with CM 1:3 standard design in 20mm square MS bar 50mm embedded in wall & 10cm projected out complete. |
| 428 | SOLAR WATER HEATING SYSTEM |
| 429 | SITC of MNRE approved & confirming to IS:12933 P-1,2,3&5 Flat Plate Collector type solar hot water system with collector, insulated stainless steel storage tank with electrical back up , MS stand for Collector &Tank etc. as required. of following capacity. |
| 430 | 250 litre/ day |
| 431 | 375 litre/ day |
| 432 | 500 litre/ day |
| 433 | 1000 litre/ day |
| 434 | BOREWELL |
| 435 | Construction of Tube-well upto 100 Meter depth and above in all type of rocks by DTH system and over burden, to accommodate casing pipe of following sizes in all types of soils and over burden including lowering of casing pipes, but excluding cost of casing pipes as per IS:2800 (Part I & II) 1979 specifications.The work would be completed after obtaining sand free water.The tube well should have a throughout bore as per nominal dia of casing pipe : |
| 436 | 200 mm dia Nominal bore. |
| 437 | Construction of tube-well from ground levels and upto 100 Meter depth and above to accommodatehousingandassemblypipeoffollowingsizesinall typesofalluvium strata by percussion / rotary drilling method and with gravel as per IS:4097-1967 and packing as per IS:2800 (Part I & II) 1979 as amended upto date (the work includes the costofgravel&itsprimarypackingandpackingduringdevelopment,loweringof housing &strainer assembly pipes, withsupply andwrappingof coir rope, wherever necessary, for arresting fine sand particles.The work will not include cost of housing pipe and strainer pipe assembly and development work, but work would be completed after obtaining sand free water). |
| 438 | 200 mm Nominal bore. |
| 439 | Development of tube well as per IS specification using suitable compressor to give and free water for required yield of the gravel packed tube well. |
| 440 | Supply of ERW M.S. black casting pipe ISI marked (IS:4270/1992) of grade Fe 410 of following sizes at site of work. |
| 441 | 200 mm nominal bore |
| 442 | Supply of strainer pipes made of ERWM.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985. |
| 443 | 200 mm Nominal Bore. |
| 444 | Testing vertically of tube-well by plumbing system and yield test and draw down test by pumping system as per IS:2800 (Part-II) 1979. |
| 445 | S & F tube well cover of tube well cover of M.S. sheet (6mm thick) with nuts and bolts complete for casing size : |
| 446 | 200mm dia. |
| 447 | S & F M.S. clamp, set of 50x6mm flat from ion with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. |
| 448 | Supply of 50mm dia G.I. medium class pipe (each length 5.8 m to 6.0 m) tripod as per drawing and design with chain pulley of 3 Mt. capacity. |
| 449 | InstallationofsubmersiblemotorpumpsetinTube-well/openwellcomplete(labour charges only) including transportation of tripod chain pulley black & any other material required for lowering purpose. |
| 450 | Providingand installingsubmersible pump and electrical panel suitable for 200 mm dia casing of bore with SS impeller, high tensile SS shaft, copper wound squirrel cage wet type induction motor 3000 rpm, 415 V, 50 Hz,3 phase A.C. supply, conformingto ISS: 8034-1976, capacity 300-500 LPM at 80-120 m headalong with a directly coupled submersible type squirrel cage electric induction 10 H.P(minimum). motor suitable for operation on 400 V, 3 phase, 50 c.p.s. A.C. supply, water lubricated bearings and provided with pivoted segment type thrust bearings to withstandnon- vertical lead with minimum wear and tear and duly fitted with device to take up the expansion of water with heating of motor, including supply, testing and commissioning of electrical panel from the same manufacturer, complete with all accessories in all respects. The contractor to obtain approval for model and make of pump set & suitable Electrical panel after having yield report of fully developed tube well and submite actual bore strata chart. |
| 451 | including supplying laying and fixing water proof PVC insulated flat submersible cable 3x10 sqmm with end termination with itsaccessories. complete in all respect as required. 1 No. 3 Phase, fully automatic star-delta starter, type - IIof 15 HP with thermal overload relay, contactor, Timer, Push Buttons and Auto-manual selector switch etc complete as required. |
| 452 | RAIN WATER HARVESTING |
| 453 | Constructionoftubewellupto100mdepthandabovetoaccomodatehousingand assemblypipeinalltypesofalluviumstratabyrotaydrillingmethodwith\"codeof practice for construction and testing of tubewells (IS:2800 (Part-II) : 1991 and IS:2800 (PartII) :1979 both amended up to date) with supply of bail plug if necessary.The work willnotincludecostofhousingpipeandstrainerpipeassemblycost,graveland development work. Work would be deemed completed only after obtaining sand free water during pumping. |
| 454 | 200 mm nominal bore |
| 455 | 250 mm nominal bore |
| 456 | Construction of Recharge Shaft in filter pit including Earth work Excavation, lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. |
| 457 | Diameter 900 mm |
| 458 | Supply & fixing Pre-cast RCC Rinngs at the mouth of recharge shaft of M20 mix with40 mm thickness |
| 459 | Diameter 900 mm |
| 460 | Supply & lowering air line of 25mm dia, G.I. pipe \"B\" class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc. |
| 461 | Supply and lowering vent air pipe 63mm dia rigid PVC pipe(IS 4985) mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge. |
| 462 | Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids |
| 463 | Size 9 to 12 mm |
| 464 | Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, withoutdeduction of voids. |
| 465 | EARTH WORK |
| 466 | Excavatingtrenchesofrequiredwidthforpipecables,etc.includingexcavationfor socketsanddressingofsides,rammingofbottoms,depthupto1.5Mtr.including takingouttheexcavatedsoil,andthenreturningthesoilasrequiredinlayersnot exceeding 20 Cm. In depth including consolidating each deposited layer by ramming wateringetc. and disposing of surplus excavatedsoil as directed within a lead of 50 Mtr.: |
| 467 | All Kinds of Soil. |
| 468 | Pipes cables etc. not exceeding 80 mm dia |
| 469 | Pipes cables etc. exceeding 80 mm dia but not exceeding 300 mm dia |
| 470 | Pipes cables etc. exceeding 300 mm dia but not exceeding 600 mm dia |
| 471 | Add extra in item No. 1.10 for excavating trench for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 Mtr. but not exceeding 3 Mtr. |
| 472 | Pipes cables etc. not exceeding 80 mm dia |
| 473 | Pipes cables etc. exceeding 80 mm dia but not exceeding 300 mm dia |
| 474 | Pipes cables etc. exceeding 300 mm dia but not exceeding 600 mm dia |
| 475 | BSR ITEMS (Rates are based on PWD Electrical BSR 2013) |
| 476 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) ofapproved make in surface / recessed ISI marked medium duty PVC conduit & it\"s accessories, round tiles, Hot Dipped Galvanized Modular Box of 20 SWG with earth terminal, 6 A Modular switch,Modular plate with grid plate,screws,making connections, testing etc. as required. Group-1. |
| 477 | Short point (up to 3 mtr.) |
| 478 | Medium point (up to 6 mtr.) |
| 479 | Long point(up to 10 mtr..) |
| 480 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) ofapproved make in surface / recessed ISI marked medium duty PVC conduit & it\"s accessories, round tiles, Hot Dipped Galvanized Modular Box of 20 SWG with earth terminal 6 A two way Modular switch, Modular plate with grid plate,screws,making connections, testing etc. as required. Group-1. |
| 481 | Medium point (up to 6 mtr.) |
| 482 | Long point(up to 10 mtr..) |
| 483 | Wiring of 3 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) ofapproved make in surface / recessed ISI marked medium duty PVC conduit & it\"s accessories, round tiles, Hot Dipped Galvanized Modular Box of 20 SWG with earth terminal 6 A modularswitch, 6 A modular socket, Modular plate with grid plate, screws, making connections, testing etc. as required. Group-1. |
| 484 | On board |
| 485 | Short point (up to 3 mtr.) |
| 486 | Medium point (up to 6 mtr.) |
| 487 | Long point(up to 10 mtr..) |
| 488 | Note-1:- Increase rate of point wiringfor FRLS PVC copper wire by 4.0 % |
| 489 | Note-1:- Increase rate of point wiringfor for using Group A1 wire by 4.0 % |
| 490 | S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required. Group-1 includingcutting the wall, covering conduit and making good the same as required. Group-1. |
| 491 | 20 mm |
| 492 | 25 mm |
| 493 | 32 mm |
| 494 | 40 mm |
| 495 | 50 mm |
| 496 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required. Group-1. |
| 497 | 2 x 1.5 sq.mm |
| 498 | 3 x 1.5 sq.mm |
| 499 | 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 500 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 501 | 4 x 6.0 sq.mm |
| 502 | 4 x 10.0 sq.mm |
| 503 | 1 x 4.0 sq.mm |
| 504 | 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. |
| 505 | 2 x 6.0 sq.mm |
| 506 | 2 x 10.0 sq.mm |
| 507 | 4 x 16.0 sq.mm |
| 508 | Note-1:-The Rate for FRLS IS : 694 wire shall be increased by 10 % |
| 509 | Note-1:- The Rate for Group A1IS : 694 wire shall be increased by7.0% |
| 510 | Supplying and drawing PVC jacketed with annealed bare copper inner conductor & tinned copper conductor shielding foam PE dielectric coaxial cable of approved make in existingsurface or recessed conduit/casing capping including making connections as required. Group-1. |
| 511 | RG - 6 |
| 512 | Supplying and fixing of power plug point Modular accessories on hot dipped galvanized modular on surface or in recessed with suitable size of grid plate with cover plate including cost ofmodular 16 amp. Switch and socket outlet, making connection , testing , etc. as required. Group-1. |
| 513 | P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. Group-1. |
| 514 | 3.0 mm thick |
| 515 | 6.4 mm thick |
| 516 | P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required. Group-A1. |
| 517 | Single pole MCB 6 A to 32 A rating |
| 518 | Double pole MCB 40 A 63 A rating |
| 519 | Four pole MCB 40 A 63 A rating |
| 520 | P&F 240/415 V Residual current circuit breaker conforming to IS:12640:1988/ IEC 61008 on existing board/sheet including making connections, testing etc. as required Gr A1 |
| 521 | Two pole 100/300mA sensitivity |
| 522 | 40 A rating |
| 523 | 63 A rating |
| 524 | P&F metal clad industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in sheet steel enclosure (without MCB) including making connections, testing etc.as required |
| 525 | Three / Four pole (Five pin) |
| 526 | 30A-32A |
| 527 | 63A |
| 528 | P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with suitable rating insulated copper wires with lugs, shorting link , neutral link, earth link and din bar,masking sheet, conforming to IS 13032 & IS 8623 including making internal DBterminations with copper lugs , testing etc. as required. |
| 529 | Double door (single phase) |
| 530 | 12 Way Gr. A1 |
| 531 | Doubledoor (Three phase) Per phase isolation |
| 532 | 2+8 Way Gr. A1 |
| 533 | 2+12 Way Gr. A1 |
| 534 | P&F recessed mounting heavy duty sheet steel End Box for distribution board duly phophatised powder coatedcomplete asrequired. Gr A1 |
| 535 | For TPN 12 way DB / all VTPN DB |
| 536 | P & F ISI marked6 amp bakelite batten/angle holder including making connection testing etc. as required. Group-1. |
| 537 | P & F IS:371 marked6 amp surface type ceiling rose including making connection testing etc. as required. |
| 538 | P & F ISI marked single tone electronic call bell including making connection testing etc. as required. Group-1. |
| 539 | P & F following modular accessories made out of unbreakable and fire retardant poly carbonate with silver contacts including making connections testing etc. as required. Group-1 |
| 540 | 6 A one way switch |
| 541 | 6 A3 pin shuttered socket |
| 542 | 16 A one way switch |
| 543 | 16 A6 pin shuttered socket |
| 544 | T.V. coaxial socket |
| 545 | 5 step fan regulator 2 Module |
| 546 | Blanking plate |
| 547 | 32 Amp. 2 Moduleswitch With Indicator |
| 548 | 25 Amp. 2 Module Socket |
| 549 | P & F following size mounting grid plates with cover plates |
| 550 | 1/2 Module |
| 551 | 3 Module |
| 552 | 8 Module |
| 553 | P & F following size hot dip galvanized M.S. box of 20 SWG with earthing terminal in recess/ surface suitable for modular accessories as required. Group-1. |
| 554 | 1-2 Module |
| 555 | 3 Module |
| 556 | 8 Module |
| 557 | S & F of PVC trunking system for cable management including finishing accessories like corners, tee, adjustable angles, junction etc. as required . The trunking system shall haveadaptable system for modular type RJ 45 data socket/ wiring accessories/ power sockets and shall be covered with peal off plastic cover. |
| 558 | 32mm X 20mm |
| 559 | 100/105mm x 50mm |
| 560 | P/Laying P.V.C./ XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required. Group-1 of size. |
| 561 | 16.0 Sq.mm |
| 562 | 4 core |
| 563 | Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty aluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required. Group-1 of size. |
| 564 | 4 x 16.0 sq.mm |
| 565 | P/Laying P.V.C./ XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with Copper conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. Group -1 Makes : Havell\"s / Polycab / KEI / RR Kabel / Gemscab ( Cable to be laid in Existing Pipe/ Masonary Duct / Cable Tray ). Unarmoured |
| 566 | 6.0 Sq.mm x 4 core |
| 567 | Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty Copper lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. |
| 568 | 4 x 6.0 sq.mm |
| 569 | Supply, Fabricating & installing following sizes of powder coatedperforated M.S. cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders, fastners, supports etc. as required. |
| 570 | 150mm x 50mm x 1.6mm |
| 571 | 300mm x 62.5mm x 2.0mm |
| 572 | Add extra @15% if GI Cable tray used in place of MS Cable tray |
| 573 | P / L of Double wall corrugated HDPE pipe confirming to IS : 14930 P - 1 & 2with HDPE Coupler at 1 mtr. Depth below the ground for laying cable including making the trench and back filling , compaction of earth as required of Gemini or IS:14930 marked make.Outer Dia. / Inner dia. |
| 574 | 90 / 76 mm |
| 575 | 120 / 103.5 mm |
| 576 | Maintenance free Gel EarthingwithPipe in pipe / Pipein striptechnologyfilled with anti corrosive conductive compound ( CPRI Tested )below the ground in 150 - 200 mm dia. earth pit & surrounding filled with required mineralfillingcompound ( MFC should have hygroscopic property to retain the moisture for long time to create low resistance zone) and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover,C.I. Frame of size 300mm x 300mm complete testing of earth resistance as required. of following sizes. |
| 577 | With Pipe in Pipe Technology (Inner pipe dia. / Outer pipe dia. ) 80 - 100 micron GI Coating |
| 578 | GI pipe 2000 mm long, 50 / 25mm, Terminal 12 mm GI Strip |
| 579 | S & Laying following size earth wire / stripin horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection etc. as required. Group-1. |
| 580 | 32mm x6mm G.I. ( Hot Dipped) Strip |
| 581 | 8 SWG copper Wire |
| 582 | Making of hole in wall of required size for housing exhaust fan and making good the same, with cement plaster as required. Group-1 of following size: |
| 583 | Up to 457 mm size |
| 584 | P & F testing joint, made out of 20mm x 3mm copper Strip, 125 mm long, with 4 no. tinned brass bolts, nuts, checknuts, spring washer etc. complete as required. |
| 585 | P & F 18 SWGM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . |
| 586 | P & F of M.S. J- hook of standard design made out of 16 mm dia. M.S. round bar and fixed withcement concrete mortar with required support as required. |
| 587 | P&F of Double ball bearing, capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible copper conductor ,making connections, testing etc. as required. Group-1. |
| 588 | 225 mm sweep |
| 589 | 300 mm sweep |
| 590 | P&F of Heavy duty capacitor start, Double ball bearing900/1400 RPM single phase ISI marked Exhaustfan, IS:2312 marked in existing opening including making connections testing etc. as required. Group-1. |
| 591 | 300 mm sweep(900/1400 RPM) |
| 592 | P & F of ventilating fans, Capacitor start, single phase with PVC impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required. Group-1. |
| 593 | 200 mm sweep |
| 594 | 250 mm sweep |
| 595 | SITC of MNRE approved & confirming to IS:12933 P-1,2,3&5 Evacuated tube Collector type solar hot water system withcollector, insulated stainless steel storage tank with electrical back up , MS standfor Collector & Tank etc. as required. Group-1 of following capacity.@160/lpd |
| 596 | 250 lpd, Tube size :- 47mm dia & 1.5mtr long = 34 Nos Or 58mm dia & 1.8mtr long = 23 Nos |
| 597 | 500 lpd, Tube size :- 47mm dia & 1.5mtr long = 64 Nos Or 58mm dia & 1.8mtr long = 44 Nos |
| 598 | Supply , Drawing and Testing of 4 pair, 24 AWG UTP Cat 6 Cable as per latest ammendments of TIA /EIA 568 B.2-1 Specifications in existing MS/PVC Conduits including making connections to Information outlets and Patch Panels with ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing required Group - 1 |
| 599 | Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , Painting etc. as required. Group-1. |
| 600 | P & F of 36Watt IP20 LED 2\"X2\" fixture, Recessed/Surface type, having efficancy of not lessthan 100 Lumen/watt, made out from CRCA housing and with high purity/transmisvity duffuser for uniform light distribution high efficiency driver electronics and in compliance to IEC standard (integral with light fixtures) life time of more than 50000 burning hours, CCT 6000 K (minimum), CRI> 80, driver maintaining PF >0.90. |
| 601 | P & Fof IP20 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Downlight with die-cast aluminum housing & Heat Sink for heat dissipation, high purity reflector with external BIS certified 2.5 KV surge protected driver having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of = 100 lm / watt andlife time of minimum35000 Burning Hours with 70% of intial Lumen maintaned, CCT 3000°K / 4000°K/ 6000°K , maximum power consumption should not more than the specified rating and Fixture shall be of CE complianed. |
| 602 | Surface Mounting |
| 603 | LED Downlight 12 W |
| 604 | LED Downlight 18/20W |
| 605 | S & Laying following size\" B \" class G.I. Pipe confirming to IS : 1239 P - 1 ( 1990 ) with accessories for laying earth conductor/strip / cable in ground/surface/recess as required |
| 606 | 32mm dia |
| 607 | 50mm dia |
| 608 | S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit along with accessories in surface / recessed using saddles, clamps, fastener pvc bushes, check nuts, as required includingcutting the wall and making good the same as required. |
| 609 | 20 mm |
| 610 | P & F extra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe including cutting, threading, drilling, fixing quarter pin etc as reqd. |
| 611 | P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd. |
| 612 | Up to 380 mm size |
| 613 | P & F of capacitor start, metal body, metal blade three speed wall mounting fan of following sweep with the help of anchor bolts including making connection testing etc. as required. |
| 614 | 400 mm sweep(Oscillating type) |
| 615 | NON BSR ITEMS (Based on market rates) |
| 616 | SITC of LED batten with reliable and robust CRCA housing structure, CRI>80, System Lumen Output of 4100 lm with a System Wattage of not more than 40 Watts and a system efficacy of 100 lm/Watts, Lifetime of 50,000 burning hours @L70, Wide Operating Voltage Range of 140V-270V, Color Temperature Options of 5700K -6500K, Power Factor = 0.95, THD<10% with Short Circuit and over voltage cut off etc as required.LM 79 and LM80 report has to be submitted for documentary verification of above Specifications. Make : |
| 617 | P & F of 1200 mm sweep double ball bearing capacitor start, aluminium body & blade ceilingfanwith down rod from 30 cm to 100 cm as required rated speed 390(+/- 10% ) RPM, Air delivery at 230 V should be 230 m³/min, Temp. rise 75 Degree Centigrade Maximum, Insulation Resistance 2 mega ohm Minimum, wiring with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. of Havell\"s SS390 or Equivalent in Usha / Orient / Crompton Make. |
| 618 | P & FDouble ball bearing and with sturdy mesh guard metal body ,3 numbers metal blales oscillating tye wall mounting Fan, including fixing with anchor bolts, adjustable upward and downward tilt mechanism, noise level should <=75 db, power consumption <=120 watts, motor protection through thermal overload protection device, 3 speed regulator making connection testing etc. as required. Make:- Havell 450mm V3 or equivalent make.450 mm sweep With three speed regulator |
| 619 | P & F of IP20Box type LED tube light fixture made from extruded aluminium housing suitable for moutning LED tube system non replaceable driver, with a minimum system lumen output of 2400 lumens and a minimum system efficiency of 110 lm/W. Power Consumption of 22W , life time of 25,000 burning hours with 70% initial lumen maintained. CCT4000°K& 6500°K. Contractor should submit LM79 & LM 80 Report of fixture & LED Lamp for conforming above specification at the time of approval of fixture.(Make PHILIPS, Havells, Crompton , Wipro , Bajaj, Polycab, Jaquar) |
| 620 | Supply and laying in ISI marked RCC hume pipe NP 3 as per IS - 458-1988 with coller etc including excavation of trench of 1.2 mtr depth & refilling the same after covering the pipe with cement concrete mixture complete in all respect as per specification. |
| 621 | 200 mm dia |
| 622 | 300 mm dia |
| 623 | FIRE FIGHTING WORK |
| 624 | Supplying, Installation, Testing & Commissioning of Local Fire authrity approved Electric Driven Main fire pump for Sprinkler / Hydrant applications suitable for automatic operation and consisting of following details given asA, B, C, D, E, F and G . |
| 625 | (A) Horizontal Single / Multi stage Centrifugal End suction, back pull type pump complete for delivery of below mentioned discharge , with necessary Butterfly valve on the suction side ( all items to be matching withthe suction side dia of the pump) and pressure gauge ,Butterfly valve and non return valve on the delivery side side ( all items to be matching withthe delivery side dia of the pump) and including bypass arrangement for Testing of pump |
| 626 | (B) Material of construction : Pump Casing - Cast Iron, Impellor- Bronze, Shaft - SS 410, Packing - Mechanical Seal |
| 627 | (C)Pump shall be capable of furnishing not less than 150 % of rated capacity at a head not less than 65 % of the rated head. The shut off head shall not exceed 120 % of rated head |
| 628 | (D) Squirrel cage induction motor suitable for 3 phase, 415 V, 50 HZ, Ac supply 2900 / 1450 RPM T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible coupling , coupling guard complete in all respect . |
| 629 | ( E)Common bed plate fabricated frommild steel channel for installation of pump and Motor |
| 630 | (F) Pump is to be inspected by third party like RITES / PDIL at manufacturer\"s premises and inspection report is to be submitted. |
| 631 | (G) Suitable cementconcreat foundation duly plastered with anti vibration pads. |
| 632 | 2280 LPM suitable for 88 Mtr Head, multi stage, 1500 RPM |
| 633 | SITC of Local fire authority approved Diesel Engine driven Pump suitable for automatic operationas per discharge defined beolw consisting of the following details given asA, B, C, D, E and F . |
| 634 | (A) Horizontal Single / Multi stage Centrifugal End suction, back pull type pump complete for delivery of below mentioned discharge complete with necessary flexible pipe, Butterfly valve on the suction side( all items to be matching with the suction side dia of the pump) and pressure gauge ,Butterfly valve and non return valve on the delivery side side ( all items to be matchingwith the delivery side dia of the pump) and including bypass arrangement for Testing of pump |
| 635 | (B) Material of construction : Pump Casing - Cast Iron, Impellor- Bronze, Shaft - SS 410, Packing - Mechanical Seal |
| 636 | (C)Pump shall be capable of furnishing not less than 150 % of rated capacity at a head not less than 65 % of the rated head. The shut off head shall not exceed 120 % of rated head |
| 637 | (D) Radiator cooled Diesel Engine developing suitable BHP for the below mentioned dischargeat 1500 / 1800 RPM, flexible coupling and coupling guard with the Pump, common bed plate for mounting of the Engine and Pump,Antivibration damping arrangement by cushy foot, Diesel Engine starting Panel for starting of the engine automatically if the Normal electrical supply fails with a unit of battery bank of 12/24v,180 Ah, Lead Acid Battery with Boost / Trickle charger as required for operation of Diesel engine, Exhaust Pipe of suitable diameter minimum 10 M length, with muffler, day oil tank of 300 1ts capacity with first charge and hand operated oil pumping set, |
| 638 | (E) Pump is to be inspected by third party like RITES / PDIL at manufacturer\"s premises and inspection report is to be submitted. |
| 639 | (F) Suitable cement concreat foundation duly plastered with anti vibration pads. |
| 640 | 2280 LPM suitable for 88 Mtr Head, multi stage, 1500 RPM |
| 641 | SITC ofLocal fire authority approved Horizontalsingle stage Jockey pump with CI Body, Bronze impellor, SS shaft, mechanical seal coupled with Squirrel cage induction motor for automatic operationsuitable for three phase, 415 V, 50 Hz AC supply with synchronous speed of 2900 RPM ,T.E.F.C type confirming to IP:55 with flexible coupling and coupling guard with the pump ,Common bed platefabricatedfrom mild steel channel , Suitable cement concreat foundation duly plastered with anti vibration pads. |
| 642 | 180 LPM suitable for 88 Mtr |
| 643 | SITC of pressure switches for Main, Jockey, Terrace pumpand standby Diesel pumps, including necessary wiring upto control panel and Ball valve. |
| 644 | Providing & fixing100mm dia bourden type, Stainless steel dial type pressure Gauge (0 - 16 Kg ) range, 3 / 8 \" BSP bottom entry on Pump Delivery Line complete with Ball valve |
| 645 | Supplying and fixing air vessel of continuous welded construction for pump room made of 450 mm dia,fabricated out of 10 mm thick dished ends and 8 mm thick MS sheet, 2000 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun Metal wheel valve, with required accessories, pressure gauge and painting with two coats of Red Oxide and two coat of post office red enamel paint as required. |
| 646 | Supplying and fixing air vessel of continuous welded constructionfixed at riser top made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun Metal wheel valve, with required accessories, pressure gauge and painting with two coats of Red Oxide and two coat of post office red enamel paint as required. |
| 647 | SITC ofLocal fire authority approved single stage Centrifugal End suction, back pull type Terrrace pump with Bronze impellor, SS shaft, mechanical seal coupled with Squirrel cage induction motor for automatic operation suitable for three phase, 415 V, 50 Hz AC supply,T.E.F.C type confirming to IP:55 with flexible coupling and coupling guard with the pump ,Common bed platefabricatedfrom mild steel channel , Suitable cement concreat foundation duly plastered with anti vibration pads.along with suitable rating Control panel as per rating ofMotorincluding 4 pole MCCB, automatic star delta starter, Single phase Preventor , overload protection rely, contactors, MCBs , interlocking wiring , ferruling etc complete in all respect. |
| 648 | 450 LPM with 35 mtr head |
| 649 | 900 LPM with 35 mtr head |
| 650 | Providing & fixing vane typewater flow switches with contacts for installation in 50 mm to 150 mm dia M.S. pipe for a service pressure up to 20 Kg / Sq.cm |
| 651 | Providing, laying, testing & Commissioning of\"C\" class heavy duty MS pipe conforming to IS 3589 / 1239 for hydrent and sprinkler applicationsincluding fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and including painting of two coats of Red Oxide , painting with two or more coats of synthetic enamel paint of Post office redshade complete as required.The installation includes all civil openings ,breakages and making good the same. |
| 652 | 25 mm dia |
| 653 | 32 mm dia |
| 654 | 40mm dia |
| 655 | 50 mm dia |
| 656 | 65 mm dia |
| 657 | 80 mm dia |
| 658 | 100 mm dia |
| 659 | 150 mm dia |
| 660 | 200 mm dia, 6.0 mm thick |
| 661 | 250 mm dia, 6.35 mm thick |
| 662 | Providing, laying, testing & Commissioning of\"C\" class heavy duty MS pipe conforming to IS 3589 and 1239 for hydrent and sprinkler underground rings including all accessories such as screwed/ welded flanges, tees, reducers etc. Conforming to IS : 1239/3589 complete including , welding, jointing with compressed asbestos gaskets, nuts, bolts etc. as required.with cleaning,wrapping and coating of the pipe with 4 mm thick tar based plymaric corrosion protection tape or equivalent including applying uniform coat of cold pipekot primer as per IS; 10221 for protection against corrsionsuitable for allkind of soil at 1.0 M depth including excavationand making good the same as requiredat site . |
| 663 | 80 mm dia |
| 664 | 150 mm dia |
| 665 | Providing, installation, testing and commissioning of dual plate non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, G I bolts, nuts, washers etc. as required. |
| 666 | 100mm dia |
| 667 | 150 mmdia |
| 668 | Supplying, fixing, testing commissioning of butterfly valve PN 1.6, with Bronze/ Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, conforming to IS 13095, of following sizes as required. |
| 669 | 50mm dia |
| 670 | 80 mm dia |
| 671 | 100mmdia |
| 672 | 150mm dia |
| 673 | 200mm dia |
| 674 | Supplying and fixing Stainless steel IS:3444 Grade - 1 single headed Internal / external yard hydrant valve with 1 No. 63 mm dia instantaneous Stainless steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal cap and chain as required. |
| 675 | Supplying and fixing 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia male and female Stainless steel couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-A) as required. |
| 676 | Supplying & fixing 63 mm dia stainless steel IS : 3444 Gr. - 1branch pipe with 20 mm (nominal internal diameter) size Gun metal nozzle confoming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required |
| 677 | Supplying and fixing first -Aid hose reel wall mounted swinging type with MS construction spray painted in post office Red, conforming to IS 884 with upto date amendments, complete with the following as required.(A) 30 m long 20 mm (nominal internal) dia water hose Thermoplastic (Textile reinforced) Type -2 as per IS: 12585 (B)20 mm (nominal internal) dia gun metal globe valve & nozzle. (C)Drum and brackets for fixing the equipments on wall.(D) Connections from riser with 40 mm dia stop valve (gun metal) & M.S. pipe |
| 678 | Supplying and fixing of Hose Cabinet of size 750 mm x 600 mm x 250 mm made of 1.6 mm thick MS sheet with 6 mm thick glazed glass doors including necessary locking arrangement suitable to accommodate external hydrant with butterfly valve, 2 Nos 15 Mtr. Long Hose pipe, 1 No. branch pipe, mounted on wall OR raised brick platform & duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect, for external hydrant, as required. |
| 679 | Providing, fixing, testing & commissioning of 15 mm dia size ,quartzoid bulb sprinkler heads suitable for 68 degree centigrade ratingof the following type : |
| 680 | Pendant type |
| 681 | Supply & Fixing of Fire Man\"s Axe with heavy Insulated rubber tested up to 20 KV and confirming to IS ;926 |
| 682 | Supply & FixingISI marked( IS : 15683 )Poratable Fire Exitnguisher,Trolleymounted Mech. Foam type capacity09 ltrs withgun-metalcapandnozzleandcompleterespectsinall respects includinginitial fill and wall suspension. |
| 683 | Supply & Fixing ISI marked ( IS : 15683 )Portable fire Extinguisher, Carbon-dioxidetype flat base including valve, dischargehose of not less than 10 mm dia. min. 600 mm long& completeinall respectsincluding initial fill with C02 gas confirming to IS:307-1966 filled to a filling ratio ofnot morethan0.667andwallsuspension bracket. Capacity 4.5 Kg. |
| 684 | Supply & FixingISI marked( IS : 15683 )Portable Fire Exitnguisher, ABC type,finished externally with red enamel paint, completein all respects includinginitial fill and wall suspension of following capacity. |
| 685 | 4 kg |
| 686 | SITC offloor mounted dust and vermin proof compartmentalisedcubical type main fire pump house panel made out of CRCA sheet , required hardware,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shadeThe panel having PU/ Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel ,hinged door with locking arrangement for equipment/switchgear. Thickness of sheet shallnot be less than 1.6 mm up to 600 mm length / widthof any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall beof 2.0 mmthick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors and having accessories ( Group -I ) as below: |
| 687 | Incomer |
| 688 | 320 Amp. TPN MCCB (adj.O/L) with Extended ROM, 35 kA, with Thermal magnetic release,Digital Ammeter, Voltmeter, Selector switches,CT, Indicating Lamps, 400 AmpsAlum. Bus bar with with heat shrinkable sleeves. |
| 689 | Out going |
| 690 | (a) 200 Amp. TPN MCCB(adj.O/L) with Extended ROM, 35 kA, with Thermal magnetic release, Digital Ammeter, Voltmeter, Selector switches,CT, Indicating Lamps for \"ON\", \"OFF\", \"TRIP\" 1 no. star Delta Starter of 75 HP with thermal over load relay, timer, push buttons, Auto / Manual selector switch, Single phase preventor - 2 Sets |
| 691 | (b) 63 Amp. TPN MCCB (adj.O/L) with Extended ROM, 25 kA, with Thermal magnetic release, Digital Ammeter, Voltmeter, Selector switches, CT, Indicating Lamps for \"ON\", \"OFF\", \"TRIP\" 1 no. Star Delta / DOL Starter of5 - 15 HP with thermal over load relay, timer, push buttons, Auto / Manual selector switch, Single phase preventor - 1 Set |
| 692 | © One no. Diesel Engine Auto Starting kit with Auto . Manual selector switch & 3 attempt starting device, timers, relays, Indicating lamp for High / Low Lub. Oil pressure, High water temperature and engine ON indication, Battery charger, suitable for 12 V / 24 V DC with trickle / boost selector switch, DC ammeter & voltmeter |
| 693 | (d) System controller to control Operation Main Electric pumps, Diesel pump, jockey pump in sequence as per specs. Consisting of relays, timers, sensors, annuciation window for fault indication. |
| 694 | Non BSR Item |
| 695 | Providing, fixing, testing & commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 8.8 Kg/cm2 and test pressure 14 Kg/cm2 to provide relief from stresses at pipe flanges.It should be complete as per manufacturer\"s specifications & as directed by Engineer- in-charge Make:- Danfoss, Resistoflex, EasyFlex |
| 696 | 200 mm dia |
| 697 | 150 mm dia |
| 698 | 100 mm dia |
| 699 | Providing & Fixing, of SS Fire brigade inlet connection (Suction collecting head) consisting of 4 nos 63 mm instantaneous type male coupling with built-in check valve and 150 mm dia flanged outlet complete with bolts,nuts and rubber insertions as per IS:904-1983 of as per approved make Newage, Minimax |
| 700 | Providing & fixing SS fire brigade suction hose coupling (draw-out connection) with nut for female coupling as per IS standards complete with 100 mm dia GI suction pipe and 100 mm dia foot valve (to be connected to static tank) of as per approved make Newage, Minimax |
| 701 | Supplying and Fixing of Y type strainer fabricated out of cast iron/ steel body, strainer shall have 1.6 mm. thick stainless steel sheet perforated screen with 3 mm. dia holes with flange at both ends complete with nuts, bolts, washers, gaskets etc of following sizes. complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. Make:- Zoloto, Kartar, Sant |
| 702 | 150 mm dia |
| 703 | 200 mm dia |
| 704 | 100 mm dia |
| 705 | Providing and fixing 4Kg Halotron™ I (Clean Agent) Type Fire Extinguisher. pressurized with Argon gas at 15 bar. Design, construction and testing as per IS 15683 with Fire rating 1A 13B, Body Hydrotested at 35 bar, Operating temperature -30°C to +55°C, external epoxy powder coating with PO Red Shade No. 538 of IS 5, Supplied with standard accessories. and wall suspension bracketsas per approved make Ceasefire, Minimax, Tyco |
| 706 | Supplying and installingfire bucket stand including sheet metal (16 gauge) shade, platform and associated civil works each stand should have four nos fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters \"Fire\" in black and gold & one no fire man\"s axe at approved locationas per approved make. |
| 707 | Supply of strong rope ladder made from 18-20 mm dia Nylone/Polypropylene (PP) rope,with 20-25 mm solid wooden/aluminium rung of length 330-370 mm and span of 370-450 mm and loading capacity of 500 kg and loading of rung with 200 kg of following length and of approved make. |
| 708 | 30 meter |
| 709 | Supply and fixing ISI marked (IS: 15683) Mono Amonia Phasphate (MAP 90)ABC type modular Fire Exitnguisher, finished externally with red enamel paint,complete in all respect incluing initial fil,Sprinkler head and ceiling suspension of following capacity of Ceasefire/ Minimax/ Tyco |
| 710 | 5 ltr. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy