Repair / Replacement Of Lt Distribution System Incl Repairs Lt Panels Apfc Panels At Adm / Domestic Area At Mil Stn Dappar Under Ge ( P ) Dappar, dappar-Punjab

Military Engineer Services-MES has published Repair / Replacement Of Lt Distribution System Incl Repairs Lt Panels Apfc Panels At Adm / Domestic Area At Mil Stn Dappar Under Ge ( P ) Dappar. Submission Date for this Tender is 30-07-2022. Electrical Panel Tenders in dappar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

33033325
Corrigendum : Repair / Replacement Of Lt Distribution System Incl Repairs Lt Panels Apfc Panels At Adm / Domestic Area At Mil Stn Dappar Under Ge ( P ) Dappar
Open Tender
Indian
Punjab
dappar
30-07-2022

Tender Details

Repair / Replacement Of Lt Distribution System Incl Repairs Lt Panels Apfc Panels At Adm / Domestic Area At Mil Stn Dappar Under Ge ( P ) Dappar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Jul-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-07-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 72000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Repair/replacement of LT distribution system incl repairs LT panels APFC panels at adm/domestic areaat Mil Stn Dappar under GE (P) Dappar
Sl. No. Item Description
1Disconnecting & taking out old unserviceable LT cable of any size and in any position.
2Supply, laying, jointing, connecting, testing & commissioning UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty 1100 volts grade with standard aluminium conductor of cross sectional area 120 sqmm x 3.5 core complete all as specified and as directed by Engr-in-Charge. NOTE - (a). The quoted rate is deemed to be inclusive of arranging respective shutdown, disconnection of cables, commissioning of feeder after the completion of job and inclusive of any minor spares and jobs required for the completion of the job. (c). The cost of excavation, returning, filling, removal and PCC cable covers will be measured and paid under relevant items of this schedule.
3Description all as per ser item No 2 here-in-before but size of LT under ground cable 150 sqmm 3.5 core.
4Description all as per ser item No 2 here-in-before but size of LT under ground cable 95 sqmm 3.5 core.
5Description all as per ser item No 2 here-in-before but size of LT under ground cable 50 sqmm 3.5 core.
6Description all as per ser item No 2 here-in-before but size of LT under ground cable 35 sqmm 3.5 core.
7Description all as per ser item No 2 here-in-before but size of LT under ground cable 25 sqmm 4 core.
8Description all as per ser item No 2 here-in-before but size of LT under ground cable 16 sqmm 4 core.
9Excavation in trenches in soft/loose/hard soil n exc 1.5 m wide and not exc 1.5 m in depth and getting out including forming bottom to required level or slope for laying pipes / laying of cable complete all as specified and as directed by Engineer-in-Charge.
10Returning filling in soft / loose soil in trenches including spreading, leveling and well ramming in 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge.
11Removal of surplus soil to a distance n exc in 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
12Material and labour sand cushioning (dry sand) to underground cable for cable protection 23 cm thick in two layers (8 cm thick before laying of cables and 15 cm thick after laying the cable and punning down the sand to 18 cm thickness.). Complete all as specified and as directed by Engineer-in-Charge. (Note:- Only punned thickness 18 cm of sand shall be measured for payment purposes).
13Supplying and laying un-rainforced precast concrete cable cover, class LV, type 1 with plat, size 250mm x 150mm x 40mm complete all as specified.
14Make bore to road width for providing GI pipe medium/light grade both end socketed for passing armoured cable complete all as specifed.
15Material and labour for galvanized iron tubing size 40 mm bore (Light grade) with all necessary fittings laid in trenches under road crossing or fixed on poles / walls / under floors for cable protectioncomplete all as specfied and as directed. Make:- Jindal. Complete all as specified and as directed by Engineer-in-Charge.
16M & L for earthingwith galvanised iron earth plate of size 600x600x6mm thick buried directly in ground not less than 2.25m below normal ground level,earth plate packed on all sides with charcoal mixed with salt in alternate layers of 15 cm thickness connected by galvanised iron earthstrip 32x6mm soldered & riveted toearth plate, galvanised iron earth strip will be provided by using 50mm bore galvanised iron pipe (light grade) earth plate to transformer body and neutralor test point of transformer, including flat iron clamp 25x3mm including bolts, nuts and washers complete including watering galvanised iron pipe 20 mm dia "Light grade" 2.5mm long the earthing includes PCC pit including necessary earth works and disposal of surplus soil to a distance not less than 50m, chamber of PCC 1:4:8 type D-2 using 40mm graded stone aggregate, coping shall be of PCC 1:3:6 type C-I using 20mm graded stone aggregate, RCC pit cover 50mm thick in1:2:4 type B-I using 20mm graded stone aggregate, rein forced with 8mm dia TMT bars @ 15cm c/c complete all as shown on sketch No 3 of SSR-I of 2009 as specified and as directed by Engr-in-Charge.
17M & L earth continuity conductor GI of 32x6 mm of GI strip by means of bolts, nuts, check nuts and GI washers complete all as specified.
18M & L Synthetic insulating mat (rubber matting), ISI Marked suitable for 1100 Volts electrical grade 2mX1mX2mm thick chequered top, ISI marked to be laid in front of LT panel board complete all as specified and as directed.
19M&L for Danger notice boards of 1.6mm thick mild steel sheet, vitreous enamelled white,with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for LT 25x20cm size complete all as specified.
20M&L for applying two coats of aluminium paint on steel tubular/rail pole of 9/11/13/15 M long externally after removal of old paint, rust, dust, oil, grease or any other foreign deposits by paint removers or burning off by blow lamps, cleaning with scrapers and chemicals for removal of rust for any number of coats of any width or girth incl. numbering of poles in blackbase & white letters paint and incl. painting five no. strips upto 30 cm on bottom of pole with black and yellow colour paint alternately all as specified and as directed by Engr-in-Charge.
21Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 25 to 50 sqmm, core outdoor type and taking down fault complete all as specified and as directed by Engr-in-Charge. Make : Denson/M Seal/Birla
22Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 70 to 120 sqmm, core outdoor type and taking down fault complete all as specified and as directed by Engr-in-Charge. Make : Denson/M Seal/Birla
23Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 150 to 185 sqmm, core outdoor type and taking down fault complete all as specified and as directed by Engr-in-Charge. Make : Denson/M Seal/Birla
24Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 240 to 300 sqmm, core outdoor type and taking down fault complete all as specified and as directed by Engr-in-Charge. Make : Denson/M Seal/Birla
25Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, S&F MCCB FP, 36kA, 400 AMPS with Thermal - Magnetic Release Type Ics = 100% Icu, Adjustable Over Load setting: 0.4 -1.0 x In, Adjustable short circuit for each phase from 1.5 - 8 x In, Make - L&T, Cat No. - CM98403OOROOGincluding spreader terminals (Make-L&T, Cat No.-ST98066OOOO) complete all as specified. NOTE - Quoted rate is deemed to be inclusive of minor jobs and minor spares required for fitment of MCCB in the existing panel.
26Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, S&F MCCB TP, 25kA, 250 AMPS with Thermal - Magnetic Release Type, Ics = 100% Icu, Adjustable Over Load setting: 0.4 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In,complete all as specified. Make - L&T, Cat No. - CM90642OOPO including spreader terminals (Make-L&T, Cat No.-ST98066OOOO)/ Schneider or equivalent
27Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, S&F MCCB TP, 25 kA, 200 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, Make - L&T, Cat No. - CM90642OONO including spreader terminals (Make-L&T, Cat No.-ST98066OOOO)/ Schneider or equivalent
28Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, S&F MCCB TP, 25 kA, 160 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, complete all as specified. Make - L&T, Cat No. - CM90642OOMO including spreader terminals (Make-L&T, Cat No.-ST98066OOOO).
29Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, S&F MCCB TP, 25 kA, 100 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, complete all as specified. Make - L&T, Schneider or equivalent
30Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, S&F MCCB TP, 25 kA, 63 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, complete all as specified. Make - L&T, Cat No. - CM91712OOJOOG including spreader terminals (Make-L&T, Cat No.-ST98066OOOO).
31Restringing and FixingACSR Conductor reinforced of any size to proper sag incl binding on insulator all as specified and as directed by Engr-in-Charge
32Cutting & trimming of tree branches any girth and sizearound overhead lines to a clear distance 1.5 mtr both sides of overhead line with in a 25 to 40 mtrs span gap of HT/LT lines including clearing the site all as specified and as directed by the Engr-in-Charge.
33M&L for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending, cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide zinc chrome primer including removing of old unserviceable rusted ones complete all as directed by Engineer-in-Charge.
34Supply, installing, testing and commissioning factory madeLT feeder pillar box Outdoor type platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA MS sheet with frontopeningtype with double door shutter and locking arrangement (including provn oflock with 2 keys), powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surfacewith TPN aluminium bus bar of rating not less than 200Amps on suitable foundation.
35M&L for sheet metal work for replacement of unsv. panel doors, bus bar cover, metering devices/relay mounting doors in complete alignment with panel"s existing doors with 3mm thick CRCA MS sheet duly powder coated with Seimens grey shade RAL 7032 or of shade as specified incld. necessary cutting of MS sheet so as to incorporate old serviceable panel accessories like LED indicating lamps, volt/ammeter, selector switches, MCCB/MCB handles, etc. welding and fixing jobs and dismantling of unsv./rusted doors to the complete satisfaction and as directed and specified by Engr-in-Charge. NOTE - (a). The contractor has to arrange for electrical shutdown prior to carry own repairs. (b). The quoted rate is deemed to be inclusive of cost of hinges, panel locks, accessories required for flush fitting of old serviecable LED indicating lamps, volt/ammeter, selector switches, MCCB/MCB handles, etc. on the new door or any other materials required for fixing and proper opereations of door.
36Supply and replace existing u/s indicating lamp LED type suitable to operate on 230 volts AC Supply of R/Y/B colour as per site requirement all as specified and as directed.
37S&F in replacement Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL131010OOOO and including suitable size CTs (set of 3) - 04 Nos. (Outgoing feeders)
38S&F in replacement Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL131010OOOO and including suitable size CTs (set of 3) - 04 Nos. (Outgoing feeders) complete all as specified
39Supply and replace existing u/s selector switch for voltmeter complete all as specified.
40Supply and replace existing u/s selector switch for Ammeter complete all as specified
41supply and replace existing unserviceable CT as that of existing ratio and model suitable for 3 phase supply complete all as specified.
42S&F in replacement Street light control junction box 280x170x130mmupto 16 sq mm 4 core cables made out of FRP sheet moulded and arrangement of incoming 3 phase 4 wire system and out going 3 phase 4 wire system with R.Y.B.& N studs and control for incoming & outgoing cables with MCB SP 2.5 Amps 230 volts with neutral link including flat iron 25x3 mm “D” clamps (2 Nos) suitable to pole of any size including bolts nuts & washers.”NOTE: - The rates includes incoming & outgoing cables glands& lugs of size up to 16 sq mm 4 core complete all as specified.
43Painting to electric control panel of E/M installations by cleaning the existing old paint with the help of mechanical tools such as wire brush, scraper and sand paper from the surface of panel and painting the prepared surface with two coat of synthatic enamel paint of approved shade over a coat of red oxide primer complete all as specified.
44Repairing/servicing of APFC panel board by replacing the all defective components with new components, re-wiring, cleaning, testing, reconnecting, re-installing and commissioning the APFC panel board complete all as specified and as directed by Engr-in-Charge.
45S&F in replacement APFC relay of 8 stage supply Voltage 415 V AC and current Input - 1A or 5 A with specs as - 3 Phase Current and Voltage measurement, PF display - 3 Digit after decimal, Individual harmonics measurement up to 31st order, Dual PF setting for Mains - DG application, Communication through Inbuilt MODBUS RS-485 Protocol all as per L&T Cat Part No. CS91050OOOO or eqivalent in Epcos/Schenider/Seimens complete all as specified.
46S&F in replacement APFC relay of 16 stage supply Voltage 415 V AC and current Input - 1A or 5 A with specs as - 3 Phase Current and Voltage measurement, PF display - 3 Digit after decimal, Individual harmonics measurement up to 31st order, Dual PF setting for Mains - DG application, Communication through Inbuilt MODBUS RS-485 Protocol all as per L&T Cat Part No. CS91051OOOO or eqivalent in Epcos/Schenider/Seimens complete all as specified.
47Dismantling, supply and install, connect, test and commission of capacitor, 3 phase, Super Heavy Duty cylindrical type, self standing units, self healing property with MPP film with safety device in the form of pressure sensitive (over pressure) mechanical interrupter, 415/440V, 3 phase, 50 Hz, Capacity 5 KVAR, AC conformance to Standards IEC 60831-1 2/96, IS 13340 including testing, commisioning as in repairs complete all as specified and as directed.
48All as per item No- 47 above but 10 KVAR.
49All as per item No- 47 above but 20 KVAR.
50All as per item No- 47 above but 25 KVAR.
51All as per item No- 47 above but 48.50 KVAR.
52S&F in repairs power capacitor duty contactor 3 phase with auxilary switch block 415 volts suitable for 10 kVAR capacitor complete with connected switch gear/ components in various APFC panels of L&T make Type MO C10 Cat Part No. CS96156 or equivalent in Makes as per PS of this CA all as specified and as directed by Engr-in-Charge.
53S&F in repairs power capacitor duty contactor 3 phase with auxilary switch block 415 volts suitable for 15 kVAR capacitor complete with connected switch gear/ components in various APFC panels of L&T make Type MO C15 Cat Part No. CS90019 or equivalent in Makes as per PS of this CA all as specified and as directed by Engr-in-Charge.
54S&F in repairs power capacitor duty contactor 3 phase with auxilary switch block 415 volts and Spreader Link Kit suitable for 25 kVAR capacitor complete with connected switch gear/ components in various APFC panels of L&T make Type MO C25 Cat Part No. CS96322 or equivalent in Makes as per PS of this CA all as specified and as directed by Engr-in-Charge.
55S&F in repairs power capacitor duty contactor 3 phase with auxilary switch block 415 volts and Spreader Link Kit suitable for 48.50 kVAR capacitor complete with connected switch gear/ components in various APFC panels of Enerlec makeor equivalent in Makes Schneider :-LC1DWK-C all as specified and as directed by Engr-in-Charge.
56S&F in repairs NC element complete switch gear/components in various APFC panels all as specified and as directed by Engr-in-Charge
57S&F in repairs NC element complete switch gear/components in various APFC panels all as specified and as directed by Engr-in-Charge
58S&F in repairs Illuminated push button- RED complete switch gear/components in various APFC panels all as specified and as directed by Engr-in-Charge
59S&F in repairs Illuminated push button- GREEN complete switch gear/components in various APFC panels all as specified and as directed by Engr-in-Charge
60S&F in repairs 1.1 KV current transformer of ratio 150/5 complete switch gear/components in various APFC panels all as specified and as directed by Engr-in-Charge
61S&F in repairs 1.5 Sqmm multistranded copper FRLSH wire for control circuit complete switch gear/components in various APFC panels all as specified and as directed by Engr-in-Charge
62S&F in repairs 2.5 Sqmm multistranded copper FRLSH wire for control circuit complete switch gear/components in various APFC panels all as specified and as directed by Engr-in-Charge
63S&F in repairs 4.0 Sqmm multistranded copper FRLSH wire for control circuit complete switch gear/components in various APFC panels all as specified and as directed by Engr-in-Charge
64S&F in repairs 6 sqmm multistranded FRLSH copper flexible cable complete switch gear/components in various APFC panels all as specified and as directed by Engr-in-Charge
65S&F in repairs 10 sqmm multistranded FRLSH copper flexible cable complete switch gear/components in various APFC panels all as specified and as directed by Engr-in-Charge
66S&F in repairs 16 sqmm multistranded single core copper conductor (Flexible) PVC Insulated Heavy Duty Industrial Cables for control circuit complete in various APFC panels all as specified and as directed by Engr-in-Charge.
67S&F in repairs 35 sqmm multistranded single core copper conductor (Flexible) PVC Insulated Heavy Duty Industrial Cables for control circuit complete in various APFC panels all as specified and as directed by Engr-in-Charge.
68S&F in repairs 1.5 sqmm pin type lugs complete switch gear/components in various APFC panels all as specified and as directed by Engr-in-Charge
69S&F in repairs 6 sqmm pin/fork/round type lugsr complete switch gear/components in various APFC panels all as specified and as directed by Engr-in-Charge
70S&F in repairs 6-32 A SP MCB, 10 kA "C" series, 240 V AC, 50 Hzcomplete switch gear/components in various APFC panels all as specified and as directed by Engr-in-Charge
71S&F in repairs 2 way selector adaptor 25 Amps complete switch gear/components in various APFC panels all as specified and as directed by Engr-in-Charge
72M&L for dismantling old unserviceable LT panel along with disconnecting connected cables, supplying, installing, testing and commissioning of 415Volts 3Phase 4 Wire factory fabricated and tested all as per existing IEC 60439 Part 1, floor mounted, IP 55 grade, Outdoor double door Partially Type Tested Assembly Type (PTTA) Bus Coupler LT cubical panel made out ofCRCA MS sheet duly powder coated with Seimens grey shade RAL 7032, dust and veremin proof with suitable size TPN PVC sleeved aluminium bus bar all as per L&T Make Ti Model or equivalent in Legrand Make Model-XL3 Panels/ Seimens Make Model-SIVACON/ABB Make Model-ArTu incld. angle iron base frame of suitable size. Panel should be mounted/grouted on 150 mm thick PCC (1:4:8) type D2 below nearest greound level and should be with 400 mm offsets on all 04 sides of the panel complete and should be inclusive of following fitted in accessories :-
73A. INCOMING -
74(i) MCCB 400 Amps ,415 V 4 pole 36 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make : Cat pat No : CM98403OOROOG including spreader terminals - set of 04 and direct rotary handle -01 No, Current transfomer 400/5A -01 Nos,Shunt Release as per OEM specifications and model or equivalent in legrand/ABB/Schenider/L&T - 02 Nos.
75B. BUSCOUPLER -
76(ii)MCCB 400 Amps ,415 V 4 pole 36 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make : Cat pat No : CM94105OOQ1OG including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 01 No. -
77C. INTERLOCKING -
78(iii). Electrical interlocking & Mech. - 02 No. all as approved by LT Panel OEM.
79D. OUTGOING -
80(iv) MCCB 200 Amps ,415 V 4 pole 35 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make : Cat pat No : CM90642OOPO including spreader terminals - set of 04 and direct rotary handle -02 No, Current transfomer 300/5A -01 Nos,Shunt Release as per OEM specifications and model or equivalent in legrand/ABB/Schenider/L&T - 01 Nos.
81(v) MCCB 125 Amps ,415 V 4 pole 35 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make : Cat pat No :including spreader terminals - set of 04 and direct rotary handle -02 No, Current transfomer 300/5A -01 Nos,Shunt Release as per OEM specifications and model or equivalent in legrand/ABB/Schenider/L&T - 03 Nos.
82(vi) MCCB TPN 63 Amp 25kA 415 volts 4 pole 50Hz -04 Nos Make -L&T Cat part no.CM91712OOHOOG
83(vii) LED indicators - R/Y/B 240 V AC - 06 Nos. for incoming
84(viii) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all as per L&T make, Cat No. - WL440010OOOO and including suitable size CTs (set of 3) - 01 No. (01 NO. for Incoming feeder)
85(ix) Single function 3 phase LED voltmeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL132010OOOO and including suitable size CTs (set of 3) - 06 Nos. (Outgoing feeders)
86(x) Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL131010OOOO and including suitable size CTs (set of 3) - 06 Nos. (Outgoing feeders)
87(xi) MCB SP "C" series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function meters) and multifunction meter - 6 Nos.
88(xii) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc.
89M&L for dismantling old unserviceable LT panel along with disconnecting connected cables, supplying, installing, testing and commissioning of 415Volts 3Phase 4 Wire factory fabricated and tested all as per existing IEC 60439 Part 1, floor mounted, IP 55 grade, Outdoor double door Partially Type Tested Assembly Type (PTTA)LT cubical panel made out ofCRCA MS sheet duly powder coated with Seimens grey shade RAL 7032, dust and veremin proof with suitable size TPN PVC sleeved aluminium bus bar all as per L&T Make Ti Model or equivalent in Legrand Make Model-XL3 Panels/ Seimens Make Model-SIVACON/ABB Make Model-ArTu incld. angle iron base frame of suitable size. Panel should be mounted/grouted on 150 mm thick PCC (1:4:8) type D2 below nearest greound level and should be with 400 mm offsets on all 04 sides of the panel complete and should be inclusive of following fitted in accessories :-
90A. INCOMING -
91(i) ACB 630 Amps ,415 V 4 pole 50 KA 50 Hz with Ics =100% Icu manual fixed type all as per L&T/Schneider or equivalent including spreader terminals - set of 04 and 1 No, Current transfomer 630/5A -01 Nos,Shunt Release as per OEM specifications and model or equivalent in legrand/ABB/Schenider/L&T - 01 Nos.
92D. OUTGOING -
93(iv) MCCB 160 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make : Cat pat No : CM90642OOMO including spreader terminals - set of 04 and direct rotary handle -02 No, Current transfomer 160/5A -01 Nos,Shunt Release as per OEM specifications and model or equivalent in legrand/ABB/Schenider/L&T - 05 Nos.
94(v) MCCB 125 Amps ,415 V 4 pole 35 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make : Cat pat No :including spreader terminals - set of 04 and direct rotary handle -02 No, Current transfomer 300/5A -01 Nos,Shunt Release as per OEM specifications and model or equivalent in legrand/ABB/Schenider/L&T - 03 Nos.
95(vii) LED indicators - R/Y/B 240 V AC - 03 Nos. for incoming
96(viii) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all as per L&T make, Cat No. - WL440010OOOO and including suitable size CTs (set of 3) - 01 No. (01 NO. for Incoming feeder)
97(ix) Single function 3 phase LED voltmeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL132010OOOO and including suitable size CTs (set of 3) - 06 Nos. (Outgoing feeders)
98(x) Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL131010OOOO and including suitable size CTs (set of 3) - 06 Nos. (Outgoing feeders)
99(xi) MCB SP "C" series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function meters) and multifunction meter - 3 Nos.
100(xii) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc.
101Note for Sl Item No. 72 and 89 above:-
1021. Panel drawing shall be approved by Engr-in-Charge. The Panel described as above complete in all respect as per specification enclosed, up to the entire satisfaction of Engineer-In-Charge.
1032. To ensure safety, reliability and accountability of component co-ordination, all the major components such as circuit breakers, contactors and the enclosure system called for in this specification should preferably be from a single manufacturer. The OEM shall be preferably manufacturer of aforesaid components and switchgear.
1043. The OEMs specified cannot authorize any other partners/sub vendors to manufacture LT Panels on their behalf. OEMs manufactured LT Panels only will be accepted and Factory Acceptance Test (FAT) has to be carried out.
105Repairing/servicing of APFC panel board ranging from 150 - 200 KVAR. by replacing the all defective components with new components, re-wiring, cleaning, testing, reconnecting, re-installing and commissioning the APFC panel board complete all as specified and directed by Engr-in-Charge.
106All as per itemabove but APFC panel board ranging from 100 - 150 KVAR..
107All as per item above but APFC panel board ranging from 50 - 100 KVAR.. NOTE FOR ITEM No - 105 to 107 Supply of cable lugs and cable tags are deemed to be included in the quoted rates.
108S&F Plastic body Instrument Cooling axial fan of 120 x 120 x 38 mm size fitted complete within the panel including cutting of a suitable sized hole on the panel body and wiring with 1.5 Sqmm copper conductor cable and MCB SPN 6 Amps all complete incld disconnecting and dismantling the old one as per satisfaction of Engr-in-Charge.
109Dismantling old unserviceable cable ducts from within the panel, S&F PVC cable ducts of size of size 45x30 MM including drawing existing cable through the ducts and commissioning the panel all as directed and specified by Engr-in-Charge. and all as per Make-L&T, Cat No. - WWA4530SG2.
110Dismantling old unserviceable DIN Rails from within the panel, S&F DIN Rail for mounting of MCBs of rating 6 to 63 Amps and of poles - 2/3/4 all as directed and specified by Engr-in-Charge.
111S&F in repairs 63 A TP MCB, 10 kA "C" series, 240 V AC, 50 Hzcomplete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy