Repair / Replacement Of Internal Wiring And Connected Items In Adm Area At Mil Stn Dappar Under Ge ( P ) Dappar
Tender Overview
Project Description
Repair / Replacement Of Internal Wiring And Connected Items In Adm Area At Mil Stn Dappar Under Ge ( P ) Dappar
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 23-Jul-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 30-Jul-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking downcarefully Copper/aluminium point wiring on wooden batten /pvc conduit /Pvc casing and capping (light/Socket/Power) complete including (Fittings such as switches, ceiling roses, pendants, regulators, sockets electric energy meters, light fittings,etcto be measured separately) removing materials to store and making good distrubed surfaces of walls. Floors etc to match with the existingincluding disconnection of ceiling/exhaust fan connection, complete all as specifed and directed by Engr-in charge. |
| 2 | Taking out existing sub main wiring of any description and size including earth wire incld wooden battens/ conduits/quities from stone/brick masonry walls, roofs, floors, etc. all as directed by Engr-In- Charge. |
| 3 | M& L in replacement of Point wiring complete with 1.5 sqmm (nominal area) PVC insulated unsheathed multistranded copper condutor single core cable 1100 volts grade FRLSH ISI marked drawn through and non metalic PVC conduit, ISI marked of not less than 20 mm dia, thickness 1.8 mm, concealed in wall, roof, etc, with all connected fittings including pressed steel terminal boxes, etc. suitable for mounting modular switches, sockets etc and including FRLSH PVC insulated unsheathed multistranded single core copper conductor cable of size 1.5 sq mm green in colour as in earth continuity conductor connected to common earth dolly and all metal parts of fittings as specified and directed for the following:-Note:- Switches , sockets, ceiling rose, regulators etc shall be measured and paid separately. Quoted rate is deemed to be inclusive of cost of cutting chases in wall for incorporting conduit and cost for making good to existing wall with CM 1:4 not exceeding 10 cm grith & painting same so as to match the existing wall.Make : Havells/polycab/Grandlay |
| 4 | (a) One light/fan/ Bell point controlled by one switch |
| 5 | (b) One lightpoint controlled by two way switch |
| 6 | (c) One 5 pin socket outlet independent 5 Amps |
| 7 | (d) One socket outlet 5 Amps on the same board with other switches. |
| 8 | (e) One 6 pin 5/15 Amps socket outlet independent with 2.5 Sqmm size copper conductor cable and2.5 sqmm copper cables as earth wire. |
| 9 | M&L in replacenent of Sub main wiring with 2 runs of single core FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 2x4 sqmm (line conductor) & 1x 4 sq mm (earth conductor), 1100 V grade drawing in & including heavy duty non metalic PVC conduit, ISI marked, incl accessories not less than 25 mm in dia & concealed in wall, roof etc including PVC insulated, FRLSH unsheathed single core multistranded copper conductor cable, green in colour as in earth conductor including cutting charges for concealed conduit wiring etc and making good cutting not exceeding 10 cm grith complete all as specified and directed.Note : (i)Two runs of copper conductor cable and one run of copper earth wire including PVC conduit will be measured and paid as one unit only. (ii). Suitable size cable lugs copper fabricated will be measured in the quoted rate only. (iii). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate. |
| 10 | All as per above but inPVC conduit with single core FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 2x1.5sqmm and 1 x 1.5 sqmm. |
| 11 | S&FModular switch 1 way 6 A, 1 module type single pole 240 volts and complete all as specified and directed by the Engr-in-charge.Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius) |
| 12 | S&F Modular switch 2 way 6 A, 1 module type single pole 240 volts and complete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius) |
| 13 | S&F Modular socket 6Amps 2/3 pin combined 2 module240 Volts complete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius) |
| 14 | S&FModular socket 6/16Amps 2/3 pin combined 2 module240 Volts complete all as specified and directed by the Engr-in-charge.Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius) |
| 15 | S&FModular switch 16Amps 2/3 pin combined 2 module240 Volts complete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius) |
| 16 | S&Fsheet metal enclosure SPN 20 Amps earth plug socket complete with all as specified and directed by Engr-in-Charge. |
| 17 | S&FModular Bell push 6 Amps 1 module 240 volts complete all as specified and directed by the Engr-in-charge.Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius) |
| 18 | S&F Modular Fan step regulator, 120 w-2 module 240 volts and complete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius) |
| 19 | S&FWhite cover plate with frame 2 module 240 volts complete all as specified and directed by the Engr-in-charge.Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius) |
| 20 | S&FWhite cover plate with frame 3 module 240 volts complete all as specified and directed by the Engr-in-charge.Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius) |
| 21 | S&FWhite cover plate with frame 4 module 240 volts and complete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius) |
| 22 | S&FWhite cover plate with frame 6 module 240 volts and complete all as specified and directed by the Engr-in-charge.Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius) |
| 23 | S&FWhite cover plate with frame 8 module 240 volts andcomplete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius) |
| 24 | S&FModular Metal Box 2 moduleand complete all as specified and directed by the Engr-in-charge.Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius) |
| 25 | S&FModular Metal Box 3 moduleand complete all as specified and directed by the Engr-in-charge.Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius) |
| 26 | S&FModular Metal Box 4 moduleand complete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius) |
| 27 | S&FModular Metal Box 6 moduleand complete all as specified and directed by the Engr-in-charge Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius) |
| 28 | S&FModular Metal Box 8 moduleand complete all as specified and directed by the Engr-in-charge. Make :Havells(Coral)/ABB(Adiya)/Legrand(Myrius) |
| 29 | S&F switch piano flush type 5/6 Amps single pole one way all as specified and directed. |
| 30 | S&F switch piano flush type 15/16 Amps single pole one way all as specified and directed. |
| 31 | M&L for socket out let 5 pin 5/6 Amps complete all as specified and directed. |
| 32 | S&F switch piano flush type 2-in-1, 6 pin 5/6 & 15/16 Amps.single pole one way all as specified and directed. |
| 33 | M&L switch socket combination 5A/16A, 5 in 1 flush type. |
| 34 | S&F switch piano flush type 5/6 Amps single pole 2 way all as specified and directed. |
| 35 | Supply and fixing in replacenment Modular Angle holder Cona/Havells/SSK withinsulated body with back plate for LED lamps all as specified and directed by the Engr-in-charge. |
| 36 | Supply and fixing in replacement LED lamp 9 watt, retrofit all as specified and directed by Engr-in-charge. MAKE : CROMPTON /HAVELLS/Philips |
| 37 | S&F in replacement LEDtube light fittings 1 x 20 W, 230V, complete with all accessories internally prewired and including connecting up with twisted flexible PVC copper conductor cable of 23/0.0076 from ceiling rose all as directed by Engr-In- Charge.MAKE : CROMPTON /HAVELLS/Philips |
| 38 | Supply and fixingin replacement ceiling rose bakelite, 63.5mm3 terminals with base plate ISI marked, complete all as specified and directed by Engr-in-charge. |
| 39 | S&F Sheet metal enclosure MCCB TPN distribution board, double door, IP 43 class, including suitable size copper bus-bar, 415V, 8 way with shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, including taking down of existing sheet metal enclosure complete all as specified and directed. Make : Legrand/ABB/Schenider. NOTE - (a). Cost of suitable size cable lugs and materials required for flush fixing of DB is deemed to be included in the quoted rate. (b). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate. |
| 40 | Supply and fixing in replacementMCBSP 6 -32 Amps,10 KA, \"C\" series 240 V ISI marked complete all as specified and directed by Engr-in-charge. MAKE : Legrand/ABB/Schenider |
| 41 | S&F for flush fixing of Sheet metal enclosure MCB SPN distribution board, double door, IP 43 class, including suitable size copper bus-bar, 240V, 8 Way with shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, including taking down of existing sheet metal enclosure complete all as specified and directed. Make : Legrand/ABB/Schenider. NOTE - (a). Cost of suitable size cable lugs and materials required for flush fixing of DB is deemed to be included in the quoted rate. (b). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate. |
| 42 | Supply and fixing in replacement MCB SPN 06-32Amps,10 KA \"C\" series 240 V ISI marked.complete all as specified and directed by Engr-in-charge. Make: Legrand/ABB/Schenider |
| 43 | Supply and fixing in replacement MCB TPN 40 Amps, 10 KA \"C\" series 415 V ISI marked complete all as specified and directed by Engr-in-charge. MAKE -Legrand/ABB/Schenider |
| 44 | Supply and fixing in replacement mirror light fitting LED 10W, 230 V, 2ft all as per Crompton Make Cat No. - LCL-14-CDL or equivalent in Philips/Wipro complete all as specified and directed by Engr-in-charge. |
| 45 | Supply and fixing in replacement Bulk Head LED 10W, 230 V, 2Ft all as per Compton Make Cat No LBHE-10-CDL complete all as specied and directed by Engr-in-Charge. |
| 46 | Supply and fixing in replacement electronic ceiling fan regulator ,rotary/socket step Modular type suitable for 220-280 V AC 50 Hz supply including all electrical connections complete as specified and as directed. |
| 47 | M&L for Taking down ceiling fan and connected cables removing it to safe place and Re-Fixing ceiling fan and connecting up including provision of cable from ceiling rose to fan complete all as specified and directed by Engr-in-charge. |
| 48 | S&F MCCB 4 pole 63 Amps, 415 V,16 KA with adjustable thermal magnetic release suitable for TPN DB as specified in Sch A HERE-IN-ABOVE all as specified and directed by Engr-in-charge. Make : Legrand/ABB/Schenider |
| 49 | M&L in replacementbell Ding Dong AC, 230 V single pole all as specified. |
| 50 | M& L Earthing complete by using GI wire as earthing lead and MS galvanized earth plate of size 60 cm x 60 cm x 6.3 mm as earth electrode surrounded by charcoal and salt, buried directly in ground vertically in pit of depth not less than 2.25 meter below the ground with top edge of the earth plate at a depth of less than 1.5 mtr below ground level surounded from all sides with mixture of charcoal dust and common salt in alternate layers and electrode connected to galvanized iron wire 4 mm dia by means of bolts, nuts, checknuts and washers of galvanised iron connected iron connected to main switch board or main control board all as shown in electrical plate No 3 of SSR 1991. Pt I and including necessary exc. and earth work. The rate also include testing, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC chambers in cement concrete (1:3:6) type CI 40 mm thick RCC(1:2:4) type B-1 cover and CI frame etc.complete all as specified and directed by Engr-in-charge. |
| 51 | Removing existing unserviceable Multi-meter box along with its enclosure, old wiring in between DB\"s/main switch/meter and S & F anti corrosive, dust proof, vermin and water proof, factory fabricated sheet metal wall mounted type Multi-meter box of size not less than 1m x 1.0m x 0.25m with 2mm thick CRCA sheet and including applying of two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer of colour as approved by Engr-in-Charge suitable to accommodate and comprising of following :-(a). Removing and re-fixing electric energy meter - 4 Nos.(b). Wiring with PVC insulated unsheathed ISI marked 2 runs of 6 sqmm and single run of 4.0 sqmm, as earth continuity, single core multi stranded copper conductor cable fixed to meter box with PVC tag connected in between incoming DB and electric meters etc complete all as specified and directed.(c). Space for accomodation of MCCB TPN DB 6 way - 01 No. NOTE - (a). The metering box must have 1 No. Dia. 32 mm incoming Cable entry hole with Gland provided at base and 4 Nos. Dia. 16 mm Outgoing cable entry holes with Gland. (b). The Multi-Meter Box should have 04 Nos. viewing windows made out of toughened glass of 5 mm thickness strategically placed so as to view the energy meter readings without opeing the door of the meter box and shall be fixed frominside of the cover of Multi-meter box with stainless steel frame (glass holder)with suitable rubber gasket from inside the cover, so that it can withstand weather effect. (c). The system shall be A.C. Single phase 250 V or three phase, four wires, 433 V, 50 Hz with effectively grounded neutral. (d). The box must include of accessories like hinges, clamp, handles etc. (e). Multi-Meter box shall be so constructed so as to have roof tapering down for easy flow of rain water. (f). It should have locking arrangement by way of sealing and can be opened without breaking. Locking arrangement shall be such that a Lock with Key for locking of Multi-Meter Box to be provided. (g). The door in closed position should be overlapped on base such that direct entry of screwdriver, tool or film is not possible. (h). The contractor has to furnish a detailed dimensional drawing showing clearly the dimensions and material of Multi-Meter Box and its constructional features for approval fro Engr-in-Charge prior to manufacturing the same. (j). Sign of danger shall be clearly and indelibly embossed (not printed) on the cover of the Multi-meter box. |
| 52 | S&F LED building security light, pressure die cast aluminum housing, 15 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete incld. of a bracket made out of 1.5 mtr long Medium grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 6 mtr from groundwith MS clamps, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as directed and specified by Engr-in-charge. MAKEof make Crompton Greaves cat part no - LSTS-15-CDL OR Equivalent in Philips/Wipro. NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. |
| 53 | Supply & Fix inreplacement only Rigid non meatalic PVC conduit heavy duty 25mm dia ISI marked with all accessories and fittings on surface of wall, ceiling and making good disturbed surface of wall to match the existing surface, complete all as specified and directed by Engr-in-charge. |
| 54 | Supply & Fix inreplacement Decorative wall light fixture made up of polycarbonate for 15 W and making good disturbed surface of wall to match the existing surface, complete all as specified and directed by Engr-in-charge. MAKECat Pat No LHDL03160069 of Havells /Bajaj/Crompton |
| 55 | Taking down existing unsv service cable andM & LayingXLPE insulated,strip armoured heavy duty electric multistranded aluminium conductor cable in repair1100 volts , 4 core 16Sq mm .Make-Havells/Polycab/Nicco |
| 56 | Excavation in trenches in soft/loose soil n exc 1.5m wide and not Exc1.5m deep and getting out includingforming bottom surfaces to required level or slope for taking out embeded cables,brick/PCCprotective tilescomplete allspecified and all as directed by Engineer-in-Charge. |
| 57 | M&L sand cushioning (drysand) to under ground cable for cable protection provided with layers 8cm deep before layingand 15 cm after laying the cable complete all as specified and directed.Note :- Punned thickness will be measured only. |
| 58 | M&L laying in trenches as cable protection cover class LV, type 2, flat size 300mm x 180mm x 40mm |
| 59 | Removal of surplus excavated soil to a distance exc 50 m but not exc in 100 m and deposited where directed at a level n\"exc 50 m above the starting point complete all as specified and directed. |
| 60 | Returning filling in soft/ loose soil in trenches including spreading, leveling watering and well ramming in 25mm thick layer complete all as specified and as specified. |
| 61 | Supply and fixing40 mm dia\"light grade\", galvanised pipe with all fitting; laid in trenches/ passing through roads alongwith cutting and making surface good with existing surface all as directed by Engr-in-charge. |
| 62 | Supply & Fix inreplacement LED slim fit low profile ceiling downlights/ Surface mounted 15W and making good disturbed surface of area to match the existing surface, complete all as specified and directed by Engr-in-charge. of Havells /Crompton |
| 63 | Supply & Fix inreplacement LED slim fit low profile ceiling downlights/ Surface mounted9W and making good disturbed surface of area to match the existing surface, complete all as specified and directed by Engr-in-charge. of Havells /Crompton |
| 64 | Supply & Fix inreplacement LED Flat panel 34W aluminum housing and PMMA diffuser makes it a robust lumininaireand making good disturbed surface of wall to match the existing surface, complete all as specified and directed by Engr-in-charge. MAKECat Pat No:LHEEBP7CUL1W034of Havells /Bajaj/Crompton |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender