| 1 | S&F 45 W LED Street light ,IP 66 ,230V environment friendly with operating temperature -10 to 50 degree celsius, operating voltage range 140 to 270 Volts, system lumen > 2500, colour temperature 5700K suitable for pole dia 43mm (max) including taking down old unserviceable security lights complete all as specified and directed.Make- Havells,Cat No-ENDURAPEARLNEOSL45WLED757PASYTOPC or equivalent make of Surya/ Crompton/Philips / BAJAJ |
| 2 | S&F 60 W LED Street light,IP 66 ,230V environment friendly with operating temperature -10 to 50 degree celsius, operating voltage range 140 to 270 Volts, system lumen 6500, colour temperature 5700K suitable for pole dia 54mm (max) including taking down old unserviceable security lights complete all as specified and directed.Make- Havells,Cat No-ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent make of Surya/ Crompton/Philips / BAJAJ |
| 3 | S&F 100 W LED Street light ,IP 66 ,230V environment friendly with operating temperature -10 to 50 degree celsius, operating voltage range 140 to 270 Volts, system lumen 4600, colour temperature 5700K suitable for pole dia 43mm (max) including taking down old unserviceable security lights completeall as specified and directed.Make- Havells,Cat No-ENDURAPEARLMAGNUMSL100WLED757PASYTOTGASTor equivalent make of Surya/ Crompton/Philips / BAJAJ |
| 4 | S&F 70 W LED floodlight ,IP 66 ,230V environment friendly with operating temperature -10 to 45 degree celsius, operating voltage range 140 to 270 Volts, system lumen >=7000, colour temperature 5700K including taking down old unserviceable security lights completeall as specified and directed.Make- Havells,Cat No-JETA PROFL70WLED757LTG or equivalent make of Surya/ Crompton/Philips / BAJAJ |
| 5 | S&F 120 W LED floodlight ,IP 66 ,230V environment friendly with operating temperature -10 to 45 degree celsius, operating voltage range 140 to 270 Volts, system lumen >=7000, colour temperature 5700K including taking down old unserviceable security lights completeall as specified and directed.Make- Havells,Cat No-JETAIRISFLS 120WLED757APWBLTG or equivalent make of Surya/ Crompton/Philips / BAJAJ |
| 6 | M&L 32-43 mm dia bore medium grade GI pipe site selectable (not less than 1.2 Mtr long bend to shape) and fixed to wall/Pole with 2 nos of mounting plate with suitable nuts and boltor fixed to pole with suitable bracket, nuts and bolts complete all as specified and directed. Make: TATA/JINDAL |
| 7 | M&Lsupports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified and directed. |
| 8 | Supply and fix 3 core 1.5 sqmm multistandard PVC insulated flexible copper cable FRLS grade including required PVC Conduit to protect the cable all as specified and directed. |
| 9 | S & F 8W LED outdoor new generation landscape lighting fitting Bambo type with 1mtr length IP 65 protection including base to stand alone complete all as specified and directed. Make - Havells model No- BAMBOOBLS8WLED830PSYMTOPC (0.6 M)or equivalent make of Surya/ Crompton/Philips / BAJAJ |
| 10 | S & F 8W LED outdoor new generation landscape lighting fitting Cone typewith IP 65 protection including base to stand alone complete all as specified and directed. Make - Havells model No- CONEBLS8WLED857PSYMTOPC (0.6 M) or equivalent make of Surya/ Crompton/Philips / BAJAJ |
| 11 | S & F 25W LED outdoor New generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source with IP 65 protection complete all as specified and directed. Make - Havells model No- CORALPT25WLED830SSYMTOPCor equivalent make of Surya/ Crompton/Philips / BAJAJ |
| 12 | Supply,Laying ,testing, and commissioning size4x16 sqmm cross-sectional areaXLPEinsulated,armoured heavy duty electric cable withaluminium conductor 1100 volts grade,in tranches /fixing on wall by saddel/ fixing on poll / drawn through GI pipes all as specified and directed. |
| 13 | All as in Item No 12 above but for cable 4 x 25 Sqmm |
| 14 | All as in Item No 12 above but for cable 3.5 x 50 Sqmm |
| 15 | All as in Item No 12 above but for cable 3.5 x 95 Sqmm |
| 16 | Excavation in trenches n.exc 1.5m wide andn.exc and 1.5 mtr in depthgetting out in in soft/loose soil all as specified and directed by Engineer-in-charge. |
| 17 | Returning and filling including spreading, leveling, watering and well ramming in layer n.exc 25 CM thick in soft/loose soil all as specified and directed by Engineer-in-charge. |
| 18 | Removing excavated material to a distance not exc. 50 mtrs and deposting where directed at a level not exceeding 1.50mm above the starting point all as specified and directed by Engineer-in-charge. |
| 19 | Supply and laying natural river sand as cushioning of cables, including spreading and punning down all as per clause No 3.21 of SSR part -I complete all as specified and directed by Engineer-in-charge and directed by Engineer in chargeNote : punned thickness will only be measured for payment purpose. |
| 20 | M&L for sub class \"B\" brick for protection of UG cable in tranches of old size brick all as specified and directed by Engineer-in-charge. |
| 21 | Supply andfixing in replacement of Aluminium conductor, steel reinforced complete all as specified and directed . |
| 22 | Supply and fixing in replacement of Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for working pressure 1100 volts grade complete all as specified anddirected . |
| 23 | Supply and fixing in replacement of Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, suitable for 1100 Volts, Height 100 mm, Width 115 mm including galvanised strap 31 x 5 mm, Nut bolts 14 mm and Washer 3 mm thick as under: complete all as specified and directed. |
| 24 | Felling of tree exc. 30 cmofgirth including cutting of trunk, and branches and stacking of serviceable material and disposal of unserviceable material to a distance n exc. 50 m and clearing site |
| 25 | S & F in repair Nature switch (Sensor based) , illumination level for switching on >= 30 Lux, and off <= 10 Lux along with part night operation facility of min 4 hrs - max 12 hrs complete all as specified and directed. Make - Healer or its equivalent |
| 26 | S & F in repair Contactors MU , 2 pole 40 A complete complete all as specified and directed. Make L&T/ABB/Siemens/Legrand |
| 27 | S & F in repair PVC pole mounted loop in loop out box210 x 310 x 116 mm made of impact assistance plastic and heat resistance material including 01 No 06A SP MCB, 04 Nos 100A rating bus bar mounted on insulators and all cable fixed withsuitable lugs andsuitable Cable Glandscomplete all as specified and as directed.Note : (a)The rate of Materials for fixinglike MS clamps, nuts, bolts & washers are demmed to be included in the unit price . (b)labour for fixing of MS clamps, nuts & bolts shall deemed to be included in unit rates. (c) Unit rate shall include the connection betweenexistingincoming LT cable lines to new junction box .Make for loop in loop out box : Hensel/Sintex , Make for MCB : Havells/L&T |
| 28 | S & F in repair PVC loop in loop out box 139x119x70 mm made of impact assistance plastic and heat resistance material and all cable fixed with appropriate connector including necessary PCC foundation for landscape lightcomplete all as specified and as directed.Note : (a)labour for fixing of nuts & bolts shall deemed to be included in unit rates. (b) Unit rate shall include the connection betweenexistingincoming LT cable lines to new junction box .Make for loop in loop out box : Hensel/Sintex,Make for MCB- Havells/L&T |
| 29 | Supply andfix GI pipe of dia 50mm to wall/Pole of medium grade with required clamping arrangements to fix with the polecomplete and connecting to the existing pipe line all as specified Make : JINDAL/TATA |
| 30 | M& L steel tublar swaged Pole paintngof approved shade (aluminium paint) over one coat with primer including taking down street light with bracket any size with applying onecoat of synthetic enamel paint withalternate coats of black and yellow paints at bottom of the pole & writing the pole number as directed and refix street light at same position as directed by Engg-in charge |
| 31 | Supply and Fix in repair 40-63 Amps MCCB, 4 pole, 16 KA \"C\" series 415 Volt, adjustable overload setting 0.8-1 x In complete all as specified and directed by Engineer-in-chargeand directed by Engr-in-charge . Make : Seimens/L&T/Schnieder/ABB/Legrand/C&S |
| 32 | Supply and fix MCCB 4 pole, microprocessor based Release range 100 Amps to 250 Amps,415V,AC,50Hz ,36 KAManual versions With Conforms to IS/IEC 60947-2,Ics=100% Icu,Suitable for Isolation Adjustable Over Load setting: 0.4 - 1.0 x In ,Adjustable Short Circuit setting: 1.5 - 10 x Ir , ,Wide Range of snap fit Internal and External Accessories including Taking down old MCCB all as specified and directed by Engineer-in-chargendMake - Seimens/L&T/Schnieder/ABB/Legrand/C&S |
| 33 | S & F Powered by inbuilt, isolated electronic LED driver (SMPS based constant current supply) for street lights/ flood lights 70 to 120 watt site selectable with lower THD, Output Open /Short Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection including taking down old unserviceable LED driver complete all as specified and directed. |
| 34 | All as in Item No-33, but for 20 to 60 watt. |
| 35 | M & L Earthing complete with GI earth plate electrode 60cmX60cmX6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connecting to galvanized earth strip 32 x 6 mm as earthing conductor by means of bolts, nuts, check nuts and washers of GI and all as shown in Electrical plate No.3 of SSR Part I and including testing on completion all as specified locations and as directed by the Engineer-in-Charge.Note: 1.The above quoted rate shall include cost of main earthing lead of 32 x 6mm GI earth strip, charcoal, salt, excavation and earth work in any type of soil CI cover, funnel with 20mm dia light grade GIwater pipe including GI protection pipe 40mm dia light grade for earth strip etc. 2. The cost of earth pit is deemed to be included in the unit rate. |
| 36 | M & L in repairs Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and directed |
| 37 | M & L in repairs Air termination, single pointed, Aluminium rod 12mm dia and 300mm long complete all as specified and directed |
| 38 | M & L in repair Air termination multi spike of copper material of height 0.9 meter lenghth complete all as specified and directed. |
| 39 | Refixing existing GI lightning Strip of any size includinginsulatings saddles and fixing screws including taking down old unsv saddles and screws complete all as specified and directed. |
| 40 | M & Lin repairs 32 x 6 mm GI strip fixed to wall on batten or on roof or recess or chases or buried in ground of size complete all as specified and directed. |
| 41 | M & Lin repairs 32 x 6 mm copper strip fixed to wall on batten or on roof or recess or chases or buried in ground of size complete all as specified and directed. |
| 42 | M & L in repairs Copper strip 20 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed |
| 43 | S & F in repairs Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed |
| 44 | Taking down old unsv Earthing of any type including all its accessories complete all as specified. Note 1:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount.Note 2-Contractor\"s supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embosed with contractor\"s firm name while carriying out any activities in defence area for better check of security purpose.Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs) |