}

Ge(S)/M-03/2022-23 Repair/Replacement And Winding Of Ceiling Fan, Electric Meter, Exhaust Fan Etc In Md/Otm Accn Of D-I, D-Ii Zone And Ajay Garrison Under Age Em Of Ge (South) Mamun, mamun-Punjab

Military Engineer Services-MES has published Ge(S)/M-03/2022-23 Repair/Replacement And Winding Of Ceiling Fan, Electric Meter, Exhaust Fan Etc In Md/Otm Accn Of D-I, D-Ii Zone And Ajay Garrison Under Age Em Of Ge (South) Mamun. Submission Date for this Tender is 04-08-2022. Ceiling Fan Tenders in mamun Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

32999129
Corrigendum : Ge(S)/M-03/2022-23 Repair/Replacement And Winding Of Ceiling Fan, Electric Meter, Exhaust Fan Etc In Md/Otm Accn Of D-I, D-Ii Zone And Ajay Garrison Under Age Em Of Ge (South) Mamun
Open Tender
Indian
Punjab
mamun
04-08-2022

Tender Details

Ge(S)/M-03/2022-23 Repair/Replacement And Winding Of Ceiling Fan, Electric Meter, Exhaust Fan Etc In Md/Otm Accn Of D-I, D-Ii Zone And Ajay Garrison Under Age Em Of Ge (South) Mamun

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Jul-2022 Amendment Other 28-07-2022
2 28-Jul-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-08-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work :REPAIR/REPLACEMENT AND WINDING OF CEILING FAN, ELECTRIC METER, EXHAUST FAN ETC IN MD/OTM ACCN OF D-I, D-II ZONE AND AJAY GARRISON UNDER AGE EM OF GE (SOUTH) MAMUN
Sl. No. Item Description
1Dismantling and taking out burnt winding by cutting, cleaningslouts and re-winding of AC ceiling fan motor1200mm/1400mm of any make of fan with super enameled heat resistant copper winding wire of existing gauge & nos of turns including, sleeve work, varnishing with E class insulation, greasing, threading, connection with flexible wire 0.472 mm copper wire upto connector block and re-assembling and testing for 4 Hrs after repair complete all as specified and directed. (Repairs will be measured and paid for separately under respective items):- Notes :- (i) Fan shall be collected by the contractor from MES store yard at thier own arrangement. (ii)Motor shall be wound with machine only and repair of fan inside complex / office of GE (S) Mamun.(iii) Khaitan/RPG/KEI or equivallent make super enameled copper winding wire shall only be used. (iv) Rates are deems to be included cost of repair /servicing & replacement of minor spare part i.e. blade screws, capacitors clumps terminal connection , split pin spring washer etc.
2All as per Srl item No 01 here-in-above butfor cabin fan/wall mounted fan complete all as specified and directed.
3Replacement of old unserviceable gun metal bush of ceiling fan complete all as specified and directed.
4Replacement of old unserviceable capacitor AC 415 volts 2.5 mfd oil filed ISI marked complete all as specified and directed.
5All as per Srl item No 04 here-in-above but 3.15mfd complete all as specified and directed.
6All as per Srl item no 04 here-in-above but 4.5 mfd complete all as specified and directed.
7Replacement of old unserviceable ball bearing of suitable size as per existing make and size of ceiling fan complete all as specified and directed.
8Replacement of old unserviceable ball bearing of suitable size as per existing make and size of exhaust fan/wall mounted Fan complete all as specified and directed.
9Replacement of old unserviceable shackle assy kit (rubber real -01, MS split clamp two Nos, nuts and bolts washers 2 Nos & split pin -02 Nos) suitable for ceiling fan 1200/1400mm sweep complete all as specified and directed.
10Replacement of old unserviceable fan blades as per existing shape, colour and design suitable for 1200mm sweep ceiling fan of any make complete all as specified and directed.
11Replacement of old unserviceable fan blades, as per existing shape, colour and design, suitable for 1400mm sweep ceiling fan of any make complete all as specified and directed.
12Repalcement of old unserviceable down rod of ceiling fan complete with split pin, hanging clamp and rubber real (length of rod not less than 45cm and not more than 60cm) complete all as specified and directed.
13Servicing of ceiling fans of capacity 1200/1400mm including taking down from site , dismantling, cleaning, greasing/oilingof bush and bearings, replacement of set of split pins, cotter pins, blade screws, cup of both side and refixing to the existing site after servicing complete all as specified and directed.(Unserviceable parts if any will be measured and paid seperately).Note:- Contractor will deployed one elect & one helper for servicing of fans against srl item no 13 & 14 at site on all working day for the period of contract.
14Servicing of exhuast fans of capacity up to 450 mm including taking down from site, dismantling, cleaning, greasing/oilingof bush and bearings, replacement of outer gasket and nut & Bolts incl cleaning of outer part & fixing wall and refixing to the existing site after servicing complete all as specified and directed.(Unserviceable parts if any shall be measured seperately).
15Supply and fixing in repalcement cable PVC insulated and overall sheathed with flexible copper conductor 3 core of size 0.5 sqmm complete all as specified and directed.
16Dismantling and Re-winding of exhaust fan/industrial wall mounting fan/pedstral fan motor 250-380mm sweep any make of fan with super enameled heat resistant copper winding wire 31 SWG to 34 SWG including cutting and getting out old brunt winding, sleeve work, varnishing with E class insulation greasing, threading, connections with twin core copper flexbile wire of size 23/0.0076mm of length not more than one mtr with each fan complete all as specified and directed. Notes:- (i) Exhaust Fan/pedestal fan shall be collected by the contractor from MES store yard at thier own arrangement.(ii)Motor shall be wound with machine only. (iii) Khaitan/RPG/KEI /RR or equivallent make super enameled copper winding wire shall only be used. (iv) Exhaust fan are deems to be included cost of repair /servicing & replacement of minor spare part i.e. body screws, capacitors clumps , clips etc.
17All as per Srl item No 16 above but 400mm-450mm sweep as per site requirement complete all as specified and directed.
18All as per Srl item No 16 above but 500mm-750mm sweep complete all as specified and directed.
19Removing old paint by scraping with sand paper including washing and filling cavaties with filter and applying two coats of painting to ceiling fan 1200-1400mm sweep at workshop with heat resistant synthetic enamel paint by spray painting incl, writing MES No on the ceiling fans as directed. Note:- Paint qaulity and colour shall be get approved from GE.
20Replacement of old unserviceable outer body of ceiling fan (bottom and uper cover plate incl all fitments such screws, gasket cover canopy of both side etc complete all as specified and directed.
21Replacement of old unserviceable electronic fan regulator step type hum free heavy duty 230 volts on existing laminated sheets complete all as specified and directed.
22Replacement of existing unserviceable canopy top & bottom of ceiling fan as per existing size & shape complete all as specified and directed.
23Replacement of existing unserviceable shutter and lover of exhaust fan as per existing size & shape complete all as specified and directed.
24Replacement of existing unserviceable MS fan bladeof exhaust fan as per existing size & shape complete all as specified and directed.
25Replacement of existing unserviceable PVC fan bladeof exhaust fan as per existing size & shape complete all as specified and directed.
26M&L for lathe work incl re-alignment to rotor, stater sloter, cleaning welding , bracing and polishing etc and refixing after repair and testing complete all as specified and directed.
27S&F in repair of Electric meter after changing of UNSV spare parts, wiringalong with sealing of meter complete all as specified and directed. Notes:- (i) Spare part items to be included in qoated rate. (ii) Contractor will provide the written warranty for one year.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail