Provision Of Reception And Security Staff Room, Provn Of Visitors Room And Office Cum Rest Room At Main Gate Under Lbw At Naval Station Bheemunipatnam Under Ge ( P ) Navy Kalinga
Tender Overview
Project Description
Provision Of Reception And Security Staff Room, Provn Of Visitors Room And Office Cum Rest Room At Main Gate Under Lbw At Naval Station Bheemunipatnam Under Ge ( P ) Navy Kalinga
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-Jul-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 03-Aug-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, FRLS cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loosesoil |
| 2 | Excavating in trenches, n exc 1.5 m wide and exc 1.5 m in depth but n exc 3.0m in depth ; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loosesoil |
| 3 | M&Lfor plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete. |
| 4 | Returning, fillingin, including spreading, levelling, watering andwell ramming in layers not exceeding 25 cm. |
| 5 | Removing excavated soilnot exc. 50 mand depositing where directed at a level n exc. 1.5 m above the starting point. |
| 6 | M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) |
| 7 | M & L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface. |
| 8 | M & L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area |
| 9 | M & L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall |
| 10 | M&L for Reinforced Cement Concrete M-30 design mix controlled concrete (Using 20mm graded granite stone aggregate) in footings, plinth beams and the like. |
| 11 | M&L for Reinforced Cement Concrete M-30 design mix controlled concrete (Using 20mm graded granite stone aggregate) in columns and pillars. |
| 12 | M&L for Reinforced Cement Concrete M-30 design mix controlled concrete (Using 20mm graded granite stone aggregate) in lintel beams, roof beams lintel beams and the like. |
| 13 | M&L for Reinforced Cement Concrete M-30 design mix controlled concrete (Using 20mm graded granite stone aggregate) in slabs supported on walls and the like. |
| 14 | M&L for Reinforced Cement Concrete M-30 design mix controlled concrete (Using 20mm graded granite stone aggregate) in chajja and the like. |
| 15 | Use and waste of form work to sides offoundation/footings, plinth beams and similar work for rough finished surfaces. |
| 16 | Use and waste of form work to sides of columns and pillarsforfair finished surfaces. |
| 17 | Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. |
| 18 | Use and waste of form work to soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work, not exceeding 200mm thick for fair finished surfaces. |
| 19 | Use and waste of form work to chajja and similar articles including edges |
| 20 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 21 | M&L for TMT bars 6mm to 8 mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 22 | M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 23 | M & L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 |
| 24 | Earth filling in floors or pavings, using surplus earth from excavation, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering |
| 25 | M & L for 100mm thick Boulder Hardcore of gauge n exc. 63 mm,deposited, spread and levelled in layers n exc.15 cm thick, watered and rammed to a true surface |
| 26 | M & L for 75 mm thick Plain Cement concrete of type D2, 1:4:8 (40 mm graded aggregate) in sub base |
| 27 | M & L for Plain Cement concrete 25 mm thicktype B-0, 1:2:4 (12.50 mm graded aggregate) in sub base |
| 28 | M & L for Ist or premium or standard quality of non skid, ceramic “coloured” joint free tiles ofsize 600x 600 x 7-8mm thick, in floor, shelves etc, set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over 15mm thick screed bed of CM 1:6 complete all as directed. |
| 29 | M & L for Ist or premium or standard quality of non skid, ceramic “coloured” joint free tiles ofsize 600 x 600 x 7-8mm thick, skirting etc. set and jointedin neat slurry and pointed in white or coloured cement to match for joint freeover backing of 10 mm thick in CM1:3 on fair faces of brick work or concrete surfaces |
| 30 | M & L for Ist or premium or standard quality of non skid, ceramic “coloured” joint free tiles ofsize 400x 400 x 7-8mm thick, in floor, shelves etc, set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over 15mm thick screed bed of CM 1:6 complete of item all as directed. |
| 31 | M&L for glazed ceramic tiles in vertical surface like skirtings dado etc., of size 300x450x8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match for joint free over backing of 10mm thick in CM1:4 on fair faces of brick work or concrete surfaces complete all as specified and directed by the Engineer-in-Charge. |
| 32 | M&L for 10 mmthick rendering as inInternal plaster on brick work or concrete surfaces in cement mortar 1:6finished even and smooth |
| 33 | M&L for 15 mmthick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:4 in double layer, using integral waterproofing compound in the outer 5mm thick layer finished fair and even. |
| 34 | M & L for Brushing neat cement slurry with 3.0 Kg of cement per Sq.m |
| 35 | M&L for5 mmthick rendering on Cellingplaster of concrete surfaces in cement mortar 1:3 complete all as specified and directed |
| 36 | Supply only Integral Water Proofing Compound [ISI marked] of approved make. |
| 37 | M&L Preparation of new surfaces ofwall and applying two coats of oil bond distemper paintincluding applying 2mm thick wall care putty on walls. |
| 38 | M & L for preparation of new surface of walls andapplying two coats of weather proof exterior emulsionover a coat of primer over 2mm thick of wall care putty for external surface on walls |
| 39 | M & L for preparation of new plastered surface and applying three coats of white wash on ceilingall as specified and directed |
| 40 | M & L for 15mm thick screed bed in CM 1:3 with water proofing compound as per manufacturer instructions applied on the surface to have a smooth surface for laying of water proofing membrane (without using extra lime or cement) (Note : WPC will be measured & paid separately) |
| 41 | M&L for normal water proofing treatment on roof slab portionconsisting with following operation :-(i) Cleaning surface by wire brushes, brooming, removing dust and applying hot blown bitumen grade 85/25 @ 1.20 Kg/Sqm(ii) Applying of Polymeric water proofing membrane wt not less than 3 Kg per Sqm over entire area with overlapping and sealed all as specified and directed(iii) Again applying hot blown bitumen 85/25 @ 1.2 Kg per Sqm over water proofing membrane(iv) Finally Applying a bituminous aluminium primer/paint @ 0.10 kg per Sqm complete all as specified and directed. |
| 42 | M&L for PCC (1:3:6) type C1 using 20 mm graded aggregate 75 mm thick as in plinth protection,finished even and fair without using extra cement complete. |
| 43 | M&L Second class hard wood Plain solid straight chowkhats and frames, wrought ,framed, rebated on the solid, rounded or chamfered ,put together with glue pinned at joints, supplied and fixed. |
| 44 | S&F 35mm thick flush shutters, solid core construction, with block board core andplywood face panels, commercial type on both covered with decorative face veneer with lipping/frame to matchside faces, the size of rail and stile as per IS 2009 (part-I). |
| 45 | S&F second class hard wood 30mm thick glazed and skeleton shutters for window , open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc, sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24(b), supplied and fitted to chowkats complete all as specified and as directed by Engineer-in-Charge. |
| 46 | S & F Aluminium ,XMPwire meshaverage width of aperture 1.40mm and fixed with aluminium wire staples |
| 47 | S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube in opening as per specification & drawing complete all as specified and as directed by the Engineer-in-Charge. |
| 48 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of mild steel tubes for top & bottom rails with mild steel frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, and with panelling of plain colour PVC sheet fitted in the mild steel frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and as directed by the Engineer-in-Charge. |
| 49 | S & F 125 mm Butt hinges, Medium weight, cold rolled mild steel, and fixed |
| 50 | S & F Aluminium handles, cast type, anodised of size 150 mm |
| 51 | S & F of 200mmAluminium anodised, barrel tower bolts of extruded section and fixed |
| 52 | S & F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed |
| 53 | S&F angle iron/ Flat iron work as in hold fast ,support of valley gutter and nosing etc. conforming to Fe-290 Gde-165 |
| 54 | M&L preparing newwoodensurfaces of any description not otherwise described , over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 55 | M&L for half brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 |
| 56 | M & L forMachine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completein steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over a screed bed of 20mm thick in cement mortar 1:4 |
| 57 | M&L for 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over a screed bed of 20mm thick in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge. |
| 58 | M & L for designer cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry with grey and cement pigment in floors over a screed bed of 20mm thick in cement mortar 1:4 |
| 59 | M&L for cement concrete 1:2:4, type B1 (20 mm graded stone aggregate) inlintels upto 1.5m clear span, copings,cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height bed plates and the like including necessary formwork, weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 60 | S&F UPVC window,(unplastisized poly-Vinyl Chloride) sliding windows multi-chambered and stiffened framed windows using 88mm x 52mm size sections all-round as main frames and shutters made with profile sections of size 57mm x 42mm, including the cost and fixing of 5mm thick clear float glass in shutters and stainless steel wire mesh shutters shall have well defined welded corner joints without any gaps, fixed the window unit to the existing masonry with anchor fasteners as required. The shutters shall have necessary handles and other associated fittings to facilitate smooth operation. Both the frames and the shutters shall be reinforced with GI profiles of thickness 1.25mm the entire window is covered with MS powder coated tube of size 40mm x 20mm all-round the frame the frame section, 10mm square bars horizontally placed at 120mmC/C and suitably placed vertically to avoid buckling and providing structural strength, Minimum weight shall be 10kg/Sqm and fixed to UPVC frames with suitable fasteners. The gaps between the window frames and masonry walls shall be filled with silicon or with any other suitable filler materials complete all as specified anddirected. Make : Rajshri Plastiwood/Sintex/Duroplast Extrusion Pvt. Ltd |
| 61 | S&F 20mm dia. (15mm internal dia.) 3-layer PP-R polypropylene random copolymer pipes SDR 7.4 UV stabilised and antimicrobial welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and as directed by the Engineer-in-Charge. |
| 62 | S&F 25mm dia. (20mm internal dia.) 3-layer PP-R polypropylene random copolymer pipes SDR 7.4 UV stabilised and antimicrobial welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and as directed by the Engineer-in-Charge. |
| 63 | S & Ffor rotational mouldedpolythene water storage tank ISI marked hoisted and fixed in position all as specified in SSR-I500 ltr capacity |
| 64 | S & Ffor Gun metal gate valve with iron wheel head ,screwed both ends for iron pipe and fixed 20 mm bore complete all as specified. |
| 65 | S & Fstainless steel pipe 25mm dia Curtain rod inclstainless steel bracket for Windows, doors opening etc |
| 66 | S & FFancy type CP Knobs for fixing curtain rod all as directed and specified |
| 67 | S & FinBib taps 15mm dia Fancy type Chromium Plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed |
| 68 | Supply and fixingVitreous china wash hand basin colour oval shapeflat black size 630 x 500mm complete all including waste coupling and waste pipe complete all as specified. |
| 69 | S & F grating doom 125 mm dia with waste hole of PTMT (Min weight 40 gms) |
| 70 | S & FVitreous China wash down water closet pan (pedestal pattern), white (including fixing bolts, low level flushing cistern of 10 Litres capacity and Seat Cover) |
| 71 | S&F15mm dia. stop valves, fancy type, chromium plated with long shank and cup (Concealed type), cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed by the Engineer-in-Charge. |
| 72 | S & F 15mm bore dia Pillar taps Fancy type, chromium plated, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed |
| 73 | S & FPVC flexible connections 15mm size with PTMT nuts of length 600mm long |
| 74 | S & F two way bib cock, CP, Fancy type - 15mm dia. |
| 75 | S & F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers |
| 76 | S & F Health Faucet for 15mm dia with 1.5mlong easy flex tube in Chrome finish and wall look |
| 77 | S & F in repairs Tubular towel rail brass chromium plated, 20mm dia,60cm long between flanges |
| 78 | Supply and fixing brass IVC soap dish (polyurethane). |
| 79 | Supply and fixing brass IVC angular stop cock including connection. |
| 80 | S&F 5.5 mm thick Sheet glass, ordinary quality and glazingin square exc 0.5 sq. m in each pane. |
| 81 | S&F 4.0 mm thick Sheet glass, ordinary quality and glazingin square nexc 0.5 sq. m in each pane. |
| 82 | S&F for 125mm dia. chromium plated brass shower rose with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed by the Engineer-in-Charge. |
| 83 | S & F for Anodised Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified (minimum thickness of powder coating 50 micron) |
| 84 | S & F for 4mm thick ACP sheet to aluminium frame/ shutterincluding joining cleat for fixing etc. complete all as specified |
| 85 | S & FPVC (SWR) pipes 40 mm dia fixed to walls |
| 86 | S & F PVC (SWR) pipes 110 mm diasingle socketed in any length with rubber ring joints fixed to walls |
| 87 | S & FPVC (SWR) pipes 110 mm diasingle socketed in any length with rubber ring joints laid in trenches. |
| 88 | M&L PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 110 mm dia drain pipe complete all as specified and directed |
| 89 | S&F 110mm dia PVC (SWR) bends any radius with access door |
| 90 | S & F PVC (SWR) pipes 75 mm diasingle socketed in any length with rubber ring joints fixed to walls |
| 91 | S & F PVC (SWR) pipes 75 mm diasingle socketed in any length with rubber ring joints laid in floors |
| 92 | S&F 75mm dia PVC (SWR) bends any radius with access door |
| 93 | S&F PVC (SWR) floor trap, plain with grating including jointing with solvent cement |
| 94 | S&F PVC (SWR) gully trap 110 mm, setting and jointing with solvent cementincluding grating |
| 95 | S&F PVC (SWR)vent cowl 110 mm, |
| 96 | M & L rendering 15mm thick on fair surfaces of brick wall or concrete surface in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed. |
| 97 | M&L PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150 mm dia drain pipe complete all as specified and directed |
| 98 | M & L for Underground drainage double wall corrugatedHDPE pipe 150 mm dia SN4 confirming to IS : 16098(PART II) single socketed in any length laid in trenches or floors etc all as specified. |
| 99 | M & L for providing Precast RCC 1:2:4, Type B-1 using 20mm graded stone aggregate as in landings, cover slabs [for manholes etc], chullah hoods, chajjas, water troughs, mangers, Shelves and similar articles with plain faces set in cement mortar 1:6 complete all as specified and as directed. |
| 100 | Removing excavated material exc 50m and not exceeding 100 m and depositing where directed. |
| 101 | M&L for cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required for 100-200 mm dia pipe |
| 102 | Demolition of Unreinforced Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 103 | Dismantling of Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings |
| 104 | Demolition of bricks/ stone ,PCC block etcbut built in cement mortar or cement lime mortar |
| 105 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 106 | Dismantling posts or struts (wood, steel or R.C.C) any section embedded in concrete, brickwork, masonry, etc including taking out embedded portion and making good disturbed ground. |
| 107 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft/ loose soil |
| 108 | M & L for Plain Cement concrete 1:2:4 type B2 (40mm graded aggregate) in foundations, filling and mass concrete. |
| 109 | S&F mild steel work conforming to Fe-290 (Gde E-165) in post, fencing posts, fillets for securing chain link fencing etc. including all necessary drilling, bolting or riveting, etc and similar work complete all as specified and directed. |
| 110 | Fabrication, erection and fixing only mild steel work conforming to Fe-290 (Gde E-165) in post, fencing posts, fillets for securing chain link fencing etc. including all necessary drilling, bolting or riveting, etc and similar work complete all as specified and directed. |
| 111 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 |
| 112 | Fabrication, erection and fixing only steel work in tubular trusses including special shaped washer etc, complete using ERW or induction butt welded tubes conforming to I:S : 1161 - 1979 Grade St-240 |
| 113 | S & F Mild Steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410 -W (Gde- E- 250) quality- A |
| 114 | S & F 12mmMild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long |
| 115 | S&F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge |
| 116 | M & L applying two coats of synthetic enamel paint over a coat of red oxide Zinc chromate primer including preparation of new steel surfacesover 10cm width or girth complete all as specified and as directed. |
| 117 | M & L applying two coats of synthetic enamel paint over a coat of red oxide Zinc chromate primer including preparation of old steel surfacesover 10cm width or girth complete all as specified and as directed. |
| 118 | M&L for construction of Septic tank conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 10 users. |
| 119 | M&L for construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8m x 3.0m effective depth. |
| 120 | Surface excavation n.exc 30cmdeep and averaging 15cm deep and getting out in soft/ loose soil. |
| 121 | M & L for 100 mm thick Plain Cement concrete of type B1, 1:2:4 (20 mm graded aggregate) in floor finish. |
| 122 | S&F machine pressed precast concrete interlocking paver blocks of approved shape and size confirming to IS 15658-2006 of 80mm thickness and M-40 grade, with grey cement and pigments complete all as specified and as directed. |
| 123 | M&L for Sand filling/ sand cushioning under floors or in foundations or for protection of UG cable etc including watering and consolidation. |
| 124 | M&L for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound of Grade A |
| 125 | M&L for Forming Construction joint 30mm deep x 10mm wide filled with sealing compound of Grade A |
| 126 | Supply and lay over wall or Surface medium class grade 20 mm dia GI pipes with all fittings laid in trenchescomplete all as specified and directed by the Engineer- in- charge |
| 127 | Supply and lay over wall or Surface medium class grade 25 mm dia GI pipes with all fittings laid in trenchescomplete all as specified and directed by the Engineer- in- charge. |
| 128 | Material and labour for point wiring for one light controlled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn carefully through existing/New concealed conduit along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and including new pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for mounting switches, sockets, fan regulators etc including testing on completion complete including making good disturbed surface all as specified and as directed. |
| 129 | All as per Item no. 128here-in-before but for one fan E/Fan point controlled by 1 one way switch and regulator all as specified and as directed. |
| 130 | All as per Item no128 above but for one 3 pin switch socket outlet, 5 Amp on independent board all as specified and as directed. |
| 131 | All as per Item no 128 here-in-before but for one switch socket outlet, 5 Amp on same board with other switches all as specified and as directed |
| 132 | All as per Item no128here-in-before but for one16 Amp 3 & 5 pin switch socket outlet, independent with 4 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 4.0 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed. |
| 133 | All as per Item no128 here-in-before but for one bell point controlled by one bell push on the same board with other switches or independent all as specified and as directed. |
| 134 | M & L for XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI mark with stranded aluminium conductor 1100 Volts grade, cross sectional area 25 Sqmm 3.5 Core laid in trenches/poles/ on wall all as specified and as directed. |
| 135 | Supply and fixingsocketcombination 2 in 1 3 pin 5 and 15 amp flush type universalall as specified and as directed. |
| 136 | Supply and fixingMetal clad plug & AC socketcombination 20A 2P +E, 230V ACall as specified and as directed. |
| 137 | Supply and fixing switch piano flush button single poleone way 5 amps all as specified and as directed. |
| 138 | S&F switch flush type, single pole Two way 5 Amps 230 voltsall as specified and as directed. |
| 139 | Supply and fixingsocketcombination 2 in 1 3 pin 5 amp flush type universalall as specified and as directed. |
| 140 | Supply and fixing ceiling rose surface bakelite three terminals all as specified and as directed. |
| 141 | Supply and fixing fan regulator electronic deluxe rotary step type all as specified and as directed. |
| 142 | Material and labour for bell ding dong AC 230 volt single pole all as specified and as directed |
| 143 | Supply and fixing bell push, flush type 6 amps all as specified and as directed. |
| 144 | Supply and fixing sheet metal enclosure for MCCB, DBs, phosphatised, Powder coated , Triple Pole and Neutral (TPN), suitable for 4 way, Double door 415 Volts all as specified and as directed. |
| 145 | Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 8 way with dim rail earth and neutral bar all as specified and as directed. |
| 146 | Supply and fixing MCB FourPole (FP) C curve 10kA breaking capacity of63 amps, 415 Volts in proper positionall as specified and as directed. |
| 147 | Supply and fixing MCB Single Pole (SP) C curve 10kA breaking capacity of6 to 32 amps, 240 Volts in proper positionall as specified and as directed. |
| 148 | S&F in proper position MCB Double Pole of capacity up to 40 amps, 240 Volts c-series with 10kA breaking capacityall as specified and as directed. |
| 149 | Supply and fixing indoor luminaire decorative batten for wall/ceiling mounting box type energy efficient saving LED BATTEN LIGHT 10 W,230 V,50 HZ, slim integrated design easyinstall incl twin twisted copper conductor flexible wire from ceiling rose to connector all as specified and as directed. |
| 150 | Supply and fixing indoor luminairedecorative batten for wall/ceiling mounting box type Extruded aluminiumhousing ,PC Diffuser, energy efficient saving LED BATTEN LIGHT 20W,230 V,50 HZ, slim integrated design easyinstallincl twin twisted copper conductor flexible wire from ceiling rose to connector all as specified and as directed. |
| 151 | S&F 10 W LEDdecorative CITY 3 wall/surfacemountingpolycarbonatebody suitable forretrofit LED Lamp Base B-22 incl lamp ,all as specified and as directed Make : Havells cat no LHDL06160099 or equivalent as approved by GE |
| 152 | Supply and fixingLED mirror light fittings 07 W,230 V,50 HZ suitable for indoor and outdoor applications completeall as specified and as directed. Makehavells or equivalent of Phillips/Crompton. |
| 153 | Supply and fixingLED bulk headfittings 10W,230 V,50 HZ suitable for indoor and outdoor applications completeall as specified and as directed. MakeSurya cat no SLE BH 10 W or equivalent as approved by GE |
| 154 | Supply and fixing on wall security LED light luminaire fitting 1X25 W and including cable for connection from celling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable including 25 mm GI bracket medium grade 1m long bent to shape including bolt, nut,washer,clamp etc all as specified and as directed by the Engineer-in-charge. |
| 155 | S&F Exhaust fan wall mount type 300 mm sweep metal body , single phase with louver shutter and connecting up including provision of hold fasts for fixing fan and louver shutter with cutting of hole and necessary PCC(1:3:6)all as specified and as directed. |
| 156 | Supply and fixing Ceiling fan of 1200 mm sweep5 STAR RATING with clamp and hook at proper position with taking down old ceiling fan and kept in MES store yard with necessary accessoriesetc all as specified and as directed. Make Havells model no : ES 40 or equivalent as approved by GE |
| 157 | Supply and fixing factory made enclosure box for mounting meter panelof size 0.6x0.6x0.2mindoor and wall mounting type made of 2mm thick MS sheet with front side openable with two nos hinged type door with locking arrangement and danger notice board, dust and vermin proof including providing all necessary electrical connection by supply and fixing single core multi stranded copper conductor FRLS cable of appropriate size, making circular hole for cable entry and exit including cable gland of required size, incl two coat of powder coated paint to out side surface and two coat of synthetic enamel paint to inside surface over a coat of red oxide , and making good the disturbed surfaces or wall etc complete incl necessary nut,bolt, washers for mounting on wall and making provisions for mounting electric meters and MCBs all as specified and as directed. |
| 158 | Supply and lay bricks common burnt clay building bricks sub-class B of size 230x113x75 completeall as directed by Engr-in-Charge. |
| 159 | Drilling of hole horizontally 80/40 mm dia bellow the road, pavement, hardstading by trenchless technology using ultra sounding technique and necessary arrangements for protection of cable by using necessary machine as directed by Engr-in-Charge. |
| 160 | Material and labour for galvanized iron tubing 50 mm bore light grade with all fitting for protection of FRLS cable, laid in trenches/wall/floor incl necessary clamp, bolt/nut if any all as specified and as directed. Note: Excavation ,earth workshall be measured and paid separately |
| 161 | Material and labour for concealed sub main wiring with two run of 4 sqmm PVC insulated unsheathed FLRS copper conductor single core multi strandedand one run of insulated copper earth wire 4 Sqmm drawn through PVC Conduit complete. Note :- Copperconductor 3 run of 4 sqmm and one run PVC conduit shall be measured as one length. |
| 162 | Supply,installation,commission and testing including providing all necessary electrical connection, LT feeder pillar box of size 0.8 m x0.8 m x 0.6 m, outdoor type 3 phase 4 wire, made of 3.15mm thick MS sheet with MS angle iron frame slanting roof, including painting necessary earth work, foundation with PCC 1:2:4 for 4 Nos legs , inclusive of under mentioned items incl provn of insulated TPN copper bus bar of appropriate size mounted on porcelain insulator and internal connection with PVC insulated strand single core copper cable/strip of suitable size(a) MCCB 4 pole, 415 volts,100amps, 25 KA = 01 No (As Incomer)(b)MCCB 4 pole, 415 volts,63 amps, 25 KA= 03 No (As outgoing) (C) LED indicator lamp (set of three-Red,Yellow,Blue) -01 set (d) Volt meter-01 , Amp meter with CT selector switch -01 |
| 163 | M&L for Earthing complete with 3 m CI pipe 80 mm dia with flanged ends, centrifugally cast, class A, in any length, joints with suitable stainless steel nuts and bolts and sufficient slot up to 2.5mtrs length buried directly and preferably vertically in ground with top flanged ended 2.5mtrs below ground label welded/connected with GI strip 32×6mm size on the top edge of the flange to bottom edge of the flanged for earthing including filling the pit with charcoal common salt surrounding the earth pipe including drilling 400 mm dia bore in any strata of soil to lower the CI pipe complete including necessary excavation and earth work PCC(1:3:6) type C-1 with 50 mm thick pre cast RCC (1:2:4) type B-1 cover slaband necessary testing on completion complete all as specified and as directed .. |
| 164 | Supply and fixing outdoor integralLED Bollard decorative mushroom shapeluminaire 9watt warm white with IP 65 ProtectioninclPCC 1:2:4 TYPE B2foundation of garden light ,copper conductor flexible wire from busbar to connector all as specified and as directed. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender