}

Supply Of Building Materials And Construction Of Bailur Grama Panchayath Building In Convergence With Mgnrega ( Mgnrega Convergency ) , Karkala Taluk- 1 Ksrb15-3-13 : Providing 12Mm Thick Cement Plaster In Single Coat With Cement Mortar 1:3, To-Karnataka

Rural Development Panchayath Raj Engineering Department-RDPRED has published Supply Of Building Materials And Construction Of Bailur Grama Panchayath Building In Convergence With Mgnrega ( Mgnrega Convergency ) , Karkala Taluk- 1 Ksrb15-3-13 : Providing 12Mm Thick Cement Plaster In Single Coat With Cement Mortar 1:3, To. Submission Date for this Tender is 21-07-2022. Construction Material Tenders in Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

32979854
Supply Of Building Materials And Construction Of Bailur Grama Panchayath Building In Convergence With Mgnrega ( Mgnrega Convergency ) , Karkala Taluk- 1 Ksrb15-3-13 : Providing 12Mm Thick Cement Plaster In Single Coat With Cement Mortar 1:3, To
Open Tender
Indian
Karnataka
21-07-2022

Tender Details

Supply Of Building Materials And Construction Of Bailur Grama Panchayath Building In Convergence With Mgnrega ( Mgnrega Convergency ) , Karkala Taluk- 1 Ksrb15-3-13 : Providing 12Mm Thick Cement Plaster In Single Coat With Cement Mortar 1:3, To Ceiling Including Rounding Off Corners Wherever Required Smooth Rendering, : Providing And Removing Scaffolding, Including Cost Of Materials, Labour, Curing Complete As Per Specifications. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 2 Ksrb 15-14.1 : Providing And Applying Two Coats With Oil Bound Washable Distemper Of Approved Brand And Shade On Wall Surface Including Priming Coat With Distemper Primer After Throughly Brooming The Surface Free From Mortar Drops And Other Foreign Matter Including Preparing The Surface Even And Sand Paper Smooth, Cost Of Materials, Labour, Complete As Per Specifications. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 3 Ksrb 15.10.3 Providing White Washing To Ceiling And / Or Sloping Roof Surface In Two Coats With Lime Of Approved Quality, To Give An Even Shade Including Cost Of Materials, Labour, Complete As Per Specifications. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 4 Ksrb 15-16.1 : Providing And Finishing External Walls In Two Coats With Waterproof Cement Paint Of Approved Brand And Shade To Give An Even Shade After Throughly Brooming The Surface To Remove All Dirt And Loose Powdered Material, Free From Mortar Drops And Other Foreign Matter Cost Of Materials, Labour, Complete As Per Specifications. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 5 Ksrb 4-2.12 : Extra For Providing Throating Or Drip Moulding To R.C.C. Chajja With Plastering ( Labour Charges Only ) As Per Specifications. Specification No. Kbs With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 6 Ksrb 9.4-3 : Providing Matti / Nandi Wood Frames Of Doors, Windows, Clerestory Windows, Ventilators And Other Frames, Wrought, Framed Or Assembled Including Making Plaster Groves ( Excluding Cost Of Cement Concrete And Side Clamps ) , But Including Cost Of Materials, Labour, Hom Of Machineries Complete As Per Specification Specification No. Kbs 9.33. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 7 Ksrb 9.7-2: Providing And Fixing In Position Fully Panelled Honne Wood Shutters For Doors, Styles And Rails Of 30Mm. Thick With Bottom And Lock Rails 180Mm Wide Top Rail And Styles 100Mm Wide As Per Drawing And Panels Of 25Mm Thick Including Cost Of Materials, Labour, Hom Of Machineries Complete As Per Specifications. ( Excluding Cost Of Fixtures ) Specification No. Kbs 9.34 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 8 Ksrb 7.9 : Providing And Fixing M.S.Grill Work For Windows And Ventilators Weighing 21Kg / Sqm Using M.S. Flats, Or M.S. Square Rods, Or Combination Of M.S. Flats And Square Rods As Per Approved Design, Drawing Including Cutting Steel Sections And Welding The Same To Required Pattern With A Coat Of Red Lead Primer, Cost Of Materials, Fixtures, Labour And Hom Of Machinery Complete As Per Specifications. Specification No. Kbs 7.12 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 9 Ksrb 9-27.1 : Fixing Of Door Frame In An Existing Opening Including Embeding Frame In Floor And Walls After Cutting Masonry For Holdfasts For Embedding Holdfast In Cement Concrete 1:3:6 Of 20Mm And Down Size Granite Metal Painting Two Coats Of Coal Tar To Sides Of Frame, Making Good The Damages To Walls And Floor As Required And Disposal Of The Debries With Lead Upto 50 M. Including Cost Of Materials, Labour Charges, Complete As Per Specifications. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 10 Ksrb 9-27.2 : Fixing Of Window Frame In An Existing Opening Including Embeeding Frame In Floor And Walls After Cutting Masonry For Holdfasts For Embedding Holdfast In Cement Concrete 1:3:6 Of 20Mm And Down Size Granite Metal Painting Two Coats Of Coal Tar To Sides Of Frame, Making Good The Damages To Walls And Floor As Required And Disposal Of The Debries With Lead Upto 50 M. Including Cost Of Materials, Labour Charges, Complete As Per Specifications. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 11 Ksrb 9-27.3 : Fixing Of Ventilator Frame In An Existing Opening Including Embeeding Frame In Floor And Walls After Cutting Masonry For Holdfasts For Embedding Holdfast In Cement Concrete 1:3:6 Of 20Mm And Down Size Granite Metal Painting Two Coats Of Coal Tar To Sides Of Frame, Making Good The Damages To Walls And Floor As Required And Disposal Of The Debries With Lead Upto 50 M. Including Cost Of Materials, Labour Charges, Complete As Per Specifications. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 12 Providing And Fixing Rcc Door Frames Factory Manufactured, With C.C. 1:1 1 / 2 :3 Reinforced With 3 Nos. Of 6 Mm Dia. Main Bars And 6 Mm Dia. Stirrups Welded At 30 Cm C / C, Vibrating, Curing Including Cost Of Steel And Fabrication Charges Having 3 Nos. Of Hinges With 20Mm X 3Mm M.S. Flat Welded With Required Iron Rods And Flats With Drilling And Fixing 4 No.Of Flat Screw Nuts Each In Concrete For Fixing Hinges And Making Necessary Provision In Concrete For Fixing Aldrops, Tower Bolts Etc., Including Cost Of One Coat Of Oil Based Enamel Primer, 4 No.Of Hold Fasts, 3 Nos. Iss Iron Oxidised Hinges Necessary Metal Screws Etc., Complete. 60Mm X 100 Mm Size-Door Frames. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 13 Providing And Fixing Factory Made Splendoor Of Solid Core Single Leaf Rigid Composite Polymer Laminated Sal Wood, Door Shutter Of Required Thickness, Manufactured Out Of Solid Core Door Conforming To Is 2202 ( Part-1 ) 1991, Laminated With 0.8 Mm Thick Polymer, Termite, Water Resistant And Fire Retardant With Superior Gluing Based On Vacuum Lamination Technology And With Various Pre Moulded Design On Both Faces Conforming To Is 6307-1985, Using Adhesive Conforming To Is 4835-1979 And Door Shuters Tested In Conformation To Is 4020-1994. The Finish Of Shutters Will Be Teadk / Oak / Cedar / Rose Wood / Walnut, Plain Colurs White / Ivory / Beige / Light Grey. Excluding Cost Of Fixtures And Inclusive Of Supply Of Shutters To Respective Work Spot. With Door Shutter 30Mm Thick. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 14 Ksrb 15-17.2 : Applying Priming Coat Over New Wood Surface And / Or Wood Based Surface After Brushing With Wood Primer Pink Paint Including Preparing The Surface After Throughly Cleaning Oil, Grease, Dirt And Foreign Matter, Sand Papering And Knotting Ready Mix Paint Including Cost Of Materials, Labour, Complete As Per Specifications. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Workmicrons. 15 Rb 15-17.6 : Providing And Applying Painting Two Coats ( Excluding Priming Coat ) On New Wood Surface And / Or Wood Based Surface With Enamel Paint To Give An Even Shade, Cleaning The Surface Of All Dirt, Dust And Foreign Matter, Sand Papering Including Cost Of Materials, Labour, Complete As Per Specifications. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 16 Providing And Fixing Vitrified Glazed Tiles Of Approved Make, Quality & Colour Of Size 600 X 600 X 10Mm Thick Fixed On A Bed Of 12Mm Thick Cement Mortar1:3 Mix, For Flooring, Skirting And Jointed With Neat Cement Slurry Mixed With Pigment To Match Shade Of Tiles, Including Providing Spacers At Required Interval And Removing Stains, Including Cost Of All Materials, Mortar, Labour, Curing Etc. Complete As Per Specification. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 17 Ksrb 14.14-5: Providing Ceramic Tiles Of Approved Make, Shade And Size For Flooring, Treads Of Steps And Landings Laid On A Bed Of 12Mm Thick, Cement Mortar 1:3 Mix, Flush Pointing With White Cement Using Colour Pigment , Including Cost Of Materials, Labour, Curing, Complete As Per Specifications. Specification No. Kbs ( For Ceramic Tiles Of Size 30 X 30Cms ) With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 18 Ksrb 14-17.1 : Providing Skirting, Dado, Rises Of Steps With White Glazed Tiles 6Mm Thick On 10Mm Thick Cement Plaster 1:3 And Jointed With White Cement Slurry Over Rough Plaster Surface ( Excluding Cost Of Rough Plastered Surface Which Should Be Measured And Paid Separately ) Using Glazed Tiles Of Approved Make And Size Including Cost Of Materials, Labour, Complete As Per Specifications. Specification No.Kbs 14.16, 14.17 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 19 Providing And Fixing Stain Less Steel 304 Grade For Stairecase Railings, Balconies, Ramps, With Hand Rail 50Mm Dia 16 Guage Hollow Pipe Welded To Vertical Hollow 50Mm Dia 16 Guage, Stainless Steel Vertical Pipe Spaced At 1.20M Regular Intervals, And 5Nos Of 25Mm Dia. Stainless Steel Hollow Hirizontal Pipe Are Welded To Vertical 50Mm Dia Hollow Pipe. The Entire Assembly Is Fixed To Stairecase Concrete By Using Expansion Blots By Drilling Concerte Etc... Complete Including Cost Of Materials, Lobour , Hom Of Machineries And Electrical Charges, Etc... Complete As Per Specifiction. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 20 Ksrb 15-18.2 : Providing And Applying Enamel Metal Paint Two Coats ( Excluding Priming Coat ) Over New Steel Or Other Metal Surface Brushing To Give An Even Shade After Cleaning Oil, Grease, Dirt And Other Foreign Matter, Including Cost Of Materials, Labour, Complete As Per Specifications.With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 21 Ksrb 1.11 : Providing And Fixing In Position Aluminium Windows And Ventilators As Per Approved Drawings With Sliding Shutters Using Three Track Window Frame Of Size 92X31.75Mm Bottom Section 1.3Mm Thick, Weight 1.07Kg / M; Sides And Top Sections 1.3 Mm, Thick, Weight 0.933 Kg / M.Shutter Frame Section Comprising Top And Bottom Section Of Size 40Mmx18mm, Wall Thickness 1.25Mm. Weight 0.417 Kg. / M. Shutter Side Outer 40Mmx18mm. Wall Thickness 1.25Mm. Weight 0.417 Kg / M, Shutter Interlock Section 40Mmx26. 7Mm Wall Thickness 1.1 Mm. Thick, Weight 0.469 Kg / M, The Shutters Mounted On Nylon Rollers With Approved Quality Of Fixtures Such As Aluminium Handles Tower Bolts Etc.; Providing And Fixing 5.5Mm. Thick Plain Glass For Shutters Fitted With Rubber Beading All Aluminium Sections Including Cutting To Required Length, Joints Mitred Subdividing The Frame Tenonned And Rivetted, In The Assembled Frame, Stiffened With End Clips For Corners, Angles Etc., And Fixed To The Walls, Lintels, Floor Beams / Cills As The Case May Be, With Necessary Steel Screws, Raul Plugs Or Teak Wood Gatties Including Cutting Masonry Or Concrete And Making Good The Original Surface Using Cement Mortar Do- Using Aluminium Section Anodized To 12- 15 Microns.With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 22 Ksrb 5-14: Providing And Constructing Load Bearing Wall With Solid Concrete Blocks 400X150x200mm Having Block Density Not Less Than 1800Kg / M3 Having A Minimum Average Compressive Strength Of 4.00 N / Mm2 Confirming To Is 2185 ( Part 1 ) 2005 And Constructed With Cm 1 A, As Per Is 25722005 Including Cost Of All Materials Labour Charges, Scaffolding, Curing, Hire Charges Of Machineries Etc., Complete As Per Specifications. Kbs No.5.4Do- With Solid Concrete Blocks Of Size 400X150x200mm With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 23 Ksrb 14.6-2 :Providing And Laying Heavy Duty Cobble Stones 75Mm Thick Interlock Pavers, Using Cement And Course Sand For Manufacture Of Blocks Of Approved Size, Shape And Colour With A Minimum Compressive Strength Of 281 Kg Per Sqm Over 50Mm Thick Sand Bed ( Average Thickness ) And Compacting With Plate Vibrator Having 3 Tons Compaction Force Thereby Forcing Part Of Sand Underneath To Come Up In Between Joints, Final Compaction Of Paver Surface Joints Into Its Final Level, Including Cost Of Materials, Labour And Hom Of Machineries Complete As Per Specifications. Specification No. Kbs With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 24 Ksrb 11-5 : Providing And Fixing White Vitreous China Clay, Water Closet European Type ( Pedestal Type, P-Trap ) With Black Solid Plastic Seat And Lid, C. P Brass Hinges, Rubber Buffers. 10 Litre Low Level, Pvc Flushing Cistern ( All Are Approved Make ) With Fittings, C. I I M.S Brackets, 40Mm Diameter Flush Bend With Fittings And Clamps, Overflow Arrangements With Special And 25Mm Mosquito Proof Coupling Of Approved Design, Painting Of Fittings And Brackets, Cutting And Rnaking Good The Wall And Floor Wherever Required, Including Cost Of Materials, Labour Complete As Per Specifications. Specification No. Kbs 11 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 25 Providing And Fixing White Vitreous China Clay Urinals With Flat Back Of Approved Make Fixed To Wooden Plugs Including Bends, Painting White To Exposed Pipes Etc., Complete As Per Directions. ( Rate Includes Cost Of All Materials And Lead ) . A Grade. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 26 Ksrb 11-11 Providing And Fixing White Vitreous China Clay, Flat Back Wash Basin Size 550 X 400Mm With A Single 15Mm C.P Brass Pillar Tap With C. I I M.S Brackets, 32 Mm C.P. Brass Waste Of Standard Pattern, Painting Of Fittings And Brackets, Cutting And Making Good The Wall And Floor Wherever Required, Including Cost Of Materials, Labour Complete As Per Specifications. Specification No. Kbs 11With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 27 Providing And Fixing Cl Nahani Trap Of Approved Make Conforming To Lsi Specifications And Construction Of Cistern In M-15 As Per Directions ( Rate Is Inclusive Of Cost Of Materials And Fixtures And Conveyance Of Materials To Work Spot ) . Do- 10Cms X 7.5Cms With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 28 Ksrb13-6.1 Providing And Fixing In Position Brass Bib Cock Of Approved Quality 15Mm Nominal Bore Including Cost Of All Materials, Labour And Hom With All Leads Complete As Per Specifications. Specification No.Kbs 13.2.2 / 13.3 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 29 Ksrb13-6.2 Providing And Fixing In Position Brass Stop Cock Of Approved Quality 15Mm Nominal Bore Including Cost Of All Materials, Labour And Hom With All Leads Complete As Per Specifications. Specification No.Kbs 13.2.2 / 13.3 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 30 Ksrb13-6.3 Providing And Fixing In Position Brass Gate Valve With C.L Wheel Of Approved Quality ( Screwed End ) 40Mm Nominal Bore Including Cost Of All Materials, Labour And Hom With All Leads Complete As Per Specifications. Specification No.Kbs 13.2.6 / 13.3 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 31 Ksrb13-6.3 Providing And Fixing In Position Brass Gate Valve With C.L Wheel Of Approved Quality ( Screwed End ) 50Mm Nominal Bore Including Cost Of All Materials, Labour And Hom With All Leads Complete As Per Specifications. Specification No.Kbs 13.2.6 / 13.3 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 32 Ksrb13-64 : Providing And Fixing In Position Brass Ball Valve High Or Low Pressure With Plastic Float Of Approved Quality 25Mm Nominal Bore Including Cost Of All Materials, Labour And Hom With All Leads Complete As Per Specifications. Specification No. Kbs With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 33 Ksrb 2-2.2 : Earthwork Excavation By Manual Means For Foundation Of Buildings, Water Supply, Sanitary Lines And Electrical Conduits Either In Pits Or In Trenches 1.5M And Above In Width, In Hard Soil Not Exceeding 1.5 M. In Depth Including Dressing The Bottom And Sides Of Pits And Trenches, Stacking The Excavated Soil Clear From Edges Of Excavation With Lead Upto 50 M. After Breaking Of Clods Complete As Per Specifications. Specification. No. Kbs 2.1 ( B ) / 2.3.5 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 34 Ksrb 5.2 : Providing And Constructing Granite I Trap I Basalt Size Stone Masonry In Foundation With Cement Mortar, 1:8 Stone Hammered Dressed In Courses Not Less Than 20 Ems High, Bond Stones At 2M. Apart In Each Course Including Cost Of Materials, Labour, Curing Complete As Per Specifications. Kbs 5.1.13 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 35 Ksrb 4.2.2 Providing And Laying In Position Reinforced Cement Concrete Of Design Mix M20 With Opc@ 320Kgs, With 20Mm And Down Size Graded Granite Metal Coarse Aggregates @0.69Cum And Fine Aggregtes @ 0.460 Cum, With Super Plasticisers @ 3 Liters Confirming To Is 9103-1999 Reafirmed-2008, Machine Mixed, Concrete Laid In Layers Not Exceeding 15 Ems Thick, Vibrated For All Works In Foundation For Footings, Pedastals, Retaining Walls, Return Walls, Walls ( Any Thickness ) Including Attached Pilasters, Columnspillars, Posts, Struts, Buttresses, Bed Blocks, Anchor Blocks & Plinths Etc., Including Cost Of All Materials, Labour, Hom Curing, Complete But Excluding Cost Of Reinforcement As Per Specifications. Specification No. Kbs 4.1, 4.6 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 36 Ksrb 4.9.2 : Providing T.M.T Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Hooking, Placing In Position, Lapping And I Or Welding Wherever Required, Tying With Binding Wire And Anchoring To The Adjoining Members Wherever Necessary Complete As Per Design ( Laps, Hooks And Wastage Shall Not Be Measured And Paid ) Cost Of Materials, Labour, Hom Complete As Per Specifications. Specification No. Kbs 4.6.3 Do- - Tmt Bars Fe 500 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 37 Ksrb13-8 : Providing And Fixing To Wall, Ceiling And Floor, Medium Density Polyethylene Pipes 6.00 Kgs / Sq.Cm Working Pressure 20Mm Outside Of Outside Diameter With Special Flange, Compression Type Fittings, Wall Clips, Making Good The Wall, Ceiling And Floor Including Cost Of All Materials, Labour Charges, Hom And Testing Complete As Per Specifications. Specification No.Kbs 13.2.15.1 I 13.9 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 38 Ksrb13-8 : Providing And Fixing To Wall, Ceiling And Floor, Medium Density Polyethylene Pipes 6.00 Kgs / Sq.Cm Working Pressure 25Mm Outside Of Outside Diameter With Special Flange, Compression Type Fittings, Wall Clips, Making Good The Wall, Ceiling And Floor Including Cost Of All Materials, Labour Charges, Hom And Testing Complete As Per Specifications. Specification No.Kbs 13.2.15.1 I 13.9 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 39 Ksrb13-9 : Providing And Fixing To Wall, Ceiling And Floor High Density Polyethylene Pipes 6.00 Kgf / Sq.Cm Working Pressure 40Mm Outside Diameter Raising Mains & Exposed Distribution Pipes With Special Flange, Compression Type Fittings, Wall Clips, Making Good The Wall, Ceiling And Floor, Including Cost Of All Materials, Labour Charges, Hom And Testing Complete As Per Specifications. Specification No. Kbs 13.2.15.2 / 13.9 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 40 Ksrb13-9 : Providing And Fixing To Wall, Ceiling And Floor High Density Polyethylene Pipes 6.00 Kgf / Sq.Cm Working Pressure 50Mm Outside Diameter Raising Mains & Exposed Distribution Pipes With Special Flange, Compression Type Fittings, Wall Clips, Making Good The Wall, Ceiling And Floor, Including Cost Of All Materials, Labour Charges, Hom And Testing Complete As Per Specifications. Specification No. Kbs 13.2.15.2 / 13.9 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 41 Ksrb13-9 : Providing And Fixing To Wall, Ceiling And Floor High Density Polyethylene Pipes 6.00 Kgf / Sq.Cm Working Pressure 75Mm Outside Diameter Raising Mains & Exposed Distribution Pipes With Special Flange, Compression Type Fittings, Wall Clips, Making Good The Wall, Ceiling And Floor, Including Cost Of All Materials, Labour Charges, Hom And Testing Complete As Per Specifications. Specification No. Kbs 13.2.15.2 / 13.9 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 42 Ksrb13-9 : Providing And Fixing To Wall, Ceiling And Floor High Density Polyethylene Pipes 6.00 Kgf / Sq.Cm Working Pressure 110Mm Outside Diameter Raising Mains & Exposed Distribution Pipes With Special Flange, Compression Type Fittings, Wall Clips, Making Good The Wall, Ceiling And Floor, Including Cost Of All Materials, Labour Charges, Hom And Testing Complete As Per Specifications. Specification No. Kbs 13.2.15.2 / 13.9 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 43 Ksrb13-8 : Providing And Fixing To Wall, Ceiling And Floor, Medium Density Polyethylene Pipes 6.00 Kgs / Sq.Cm Working Pressure 160Mm Outside Diameter With Special Flange, Compression Type Fittings, Wall Clips, Making Good The Wall, Ceiling And Floor Including Cost Of All Materials, Labour Charges, Hom And Testing Complete As Per Specifications. Specification No.Kbs 13.2.15.1 I 13.9 For Internal Water Supply Connection With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 44 Ksrb 12-8.1 : Constructing Brick Masonry Inspection Chamber 600X600mm And 450Mm Depth ( Clear Inside Dimension ) For Single Pipeline, Using Table Moulded Non-Modular Bricks Of Class Designation 50 In Cement Mortar 1:5, C I Cover Withframe ( Light Duty ) Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38 Kg ( Weight Of Cover 23Kg And Weight Of Frame 15 Kg ) R. C. C. Top Slab With Cement Concrete M 15 With 20Mm And Downsize Granite Metal, Foundation Concrete M 5 With 40Mm And Downsize Granite Metal Inside Plastering 12Mm Thick With Cement Mortar 1:3, Finish Smooth With A Floating Coat Of Cement On Walls And Bed Concrete Complete As Per Standard Design Including Cost Of Materials, Labour Charges, Curing Complete As Per Specifications. Specification No. Kbs With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 45 Ksrb 12-8.1 : Constructing Brick Masonry Inspection Chamber 450X450mm And 450Mm Depth ( Clear Inside Dimension ) For Single Pipeline, Using Table Moulded Non-Modular Bricks Of Class Designation 50 In Cement Mortar 1:5, C I Cover Withframe ( Light Duty ) Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38 Kg ( Weight Of Cover 23Kg And Weight Of Frame 15 Kg ) R. C. C. Top Slab With Cement Concrete M 15 With 20Mm And Downsize Granite Metal, Foundation Concrete M 5 With 40Mm And Downsize Granite Metal Inside Plastering 12Mm Thick With Cement Mortar 1:3, Finish Smooth With A Floating Coat Of Cement On Walls And Bed Concrete Complete As Per Standard Design Including Cost Of Materials, Labour Charges, Curing Complete As Per Specifications. Specification No. Kbs With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 46 Ksrb 13-11 : Providing And Placing On Terrace, Polyethylene Water Storage Tanks As Per Is12701 : 1996 With Manhole Lid And Suitable Locking Arrangements, Making Holes Of Suitable Diameter For Inlet, Outlet And Over Flow Pipes, Including Cost Of All Materials, Labour, Transport Charges, Hom And Testing Complete As Per Specifications. ( For 1000 Litre Capacity ) Specification No.Kbs 13.22 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 47 Ksrb 11-15.5 Providing And Fixing 1500X450mm Dia Rectangular Shape Mirror With Plastic Moulded Frame Of Approved Make And Shade With 6Mm Thick Hard Board Backing Including Cost Of Materials, Labour Complete As Per Specifications With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 48 Ksrb 11-17-1 Providing And Fixing C.P. Brass Towel Rail 740Mm Length, 20Mm Dia With C. P Brackets, Fixed To Wooden Cleats With C.P. Brass Screws Including Cost Of Materials, Labour Complete As Per Specifications. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 49 Providing And Fixing 7.5 Ems To 15.00 Ems Dia Np Grating 100 Mm Dia. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 50 Providing And Fixing Unplasticised Pvc Connection Pipe With Brass Union 15Mm Nominal Bore 450Mm Nominal Bore Of Pvc Connection Including Cost Of All Materials, Labour And Hom With All Leads Complete As Per Specifications. Specification No. Kbs With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 51 Supplying And Wiring Adopting Loop System In Existing Pvc Conduit / Casing Capping Using 1100V Grade, Copper Conductor Flexible Multicore Frpvc Insulated, Extruded Fr Pvc Outer Sheathed 2C X1.5Sq.Mm Cable Confirming To The Gtp Of Page No.____ Without Switch, The Other End Of The Wires Shall Be Terminated With Sufficient Loose Length In A Wood / Pvc Round Block. Complete For Each Outlet. Using Class A Materials. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work A ) Short Point Up To 3Mtr From Tapping Point To Out Let Via Switch Box 52 B ) Medium Point Above 3Mtr Up To 6Mtr From Tapping Point To Out Let Via Switch Box 53 C ) Long Point Above 6Mtr Up To 10Mtr From Tapping Point To Out Let Via Switch Box 54 D ) Two Outlet In A Row, Above 3Mtr Up To 6Mtr From Tapping Point To Out Let Via Switches 55 Supplying Heavy Gauge Pvc Conduit Pipe ……Mm Dia .......Mm Thick Confirming To Is 2509 With Suitable Size Bends, Metal / Pvc Junction Boxes Adhesive Paste Etc., And Running Before Concreting The Slab. The Conduit Should Be Tied To The Reinforcement Rods By Using Binding Wires And Unused Ways Of Junction Boxes And Pipe Ends Should Be Covered Using Pvc End Enclosures, Run With 18Swg Gi Fish Wire Wherever Necessary With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work A ) 19 / 20Mm Dia 2Mm Thick 56 B ) 25Mm Dia 2Mm Thick 57 Open Conduit System - Supplying Heavy Gauge Pvc Conduit Pipe …….Dia .......Mm Thick Confirming To Is 2509 With Suitable Size Bends, Junction Boxes, Adhesive Paste Etc., And Fixing Using Inverted Wood Plugs In Case Of Rcc Ceiling And Rcc Wall Stone Structure Or Rawl Plugs In Case Of Brick Walls And Cement Plastering Damaged Portion Using Heavy Gauge Saddles At An Interval Of 700Mm Using Nf Screws. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work A ) 19 / 20Mm Dia 2Mm Thick 58 B ) 25Mm Dia 2Mm Thick 59 Ksrb 4.2.2 Providing And Laying In Position Reinforced Cement Concrete Of Design Mix M20 With Opc@ 320Kgs, With 20Mm And Down Size Graded Granite Metal Coarse Aggregates @0.69Cum And Fine Aggregtes @ 0.460 Cum, With Super Plasticisers @ 3 Liters Confirming To Is 9103-1999 Reafirmed-2008, Machine Mixed, Concrete Laid In Layers Not Exceeding 15 Ems Thick, Vibrated For All Works In Foundation For Footings, Pedastals, Retaining Walls, Return Walls, Walls ( Any Thickness ) Including Attached Pilasters, Columnspillars, Posts, Struts, Buttresses, Bed Blocks, Anchor Blocks & Plinths Etc., Including Cost Of All Materials, Labour, Hom Curing, Complete But Excluding Cost Of Reinforcement As Per Specifications. Specification No. Kbs 4.1, 4.6 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work A ) 4-5 Way 60 A ) 6 Way 61 A ) 8 Way 62 A ) 10-12 Way 63 Ksrb13-9 : Providing And Fixing To Wall, Ceiling And Floor High Density Polyethylene Pipes 6.00 Kgf / Sq.Cm Working Pressure 50Mm Outside Diameter Raising Mains & Exposed Distribution Pipes With Special Flange, Compression Type Fittings, Wall Clips, Making Good The Wall, Ceiling And Floor, Including Cost Of All Materials, Labour Charges, Hom And Testing Complete As Per Specifications. Specification No. Kbs 13.2.15.2 / 13.9 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work A ) 4 Module 64 A ) 6 Module 65 A ) 8 Module 66 A ) 12 Module 67 Supplying And Fixing Of Modular Switch / Socket / Stepped Electronic Fan Regulator / Dimmer / Telephone Socket Etc On Existing Modular Switch Plate As Per Is 3854 And Is 1293 Using Group A Materials 6Amps One Way. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 68 Supplying 6A Flush / Projected Type Socket And 6 Amps Flush / Projected Type Sp Switch Either Surface / Flush Mounting In Existing Gang Box Or In 4Mm Thick Plastic Sheet And Fixing Over A Flush Mounted Wooden Box And Wiring Using Necessary Capacity Wires As Required As Per Is 1293 And Is 3654 6Amps 3 / 5 Way With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 69 Supply And Fixing Of Bakelite D.P / Socket / Switch With / Without Neon Indicator Over Existing Wood Board Or Flush Mounting In Plastic Plates / Nitches As Per Is 1293 And Is 3654 Using Group A Material. 32Amps Flush / Projected Type Dp Switch With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 70 Supplying And Fixing Of Modular Switch / Socket / Stepped Electronic Fan Regulator / Dimmer / Telephone Socket Etc On Existing Modular Switch Plate As Per Is 3854 And Is 1293 Using Group A Material. 6 / 16Amps Universal Socket With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 71 Supplying And Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards Using Necessary Fixing Materials And C Type Curve , Indicator On / Off, Energy Cross-3 With Short Circuit Breaking Capacity Of 10K And Complete Wiring As Required To Iec 60898 With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work A ) 5-32 Amps Sp 72 A ) 5-32 Amps Dp 73 A ) 40-63 Amps Dp 74 Supplying And Fixing Regular Mcb Distribution Boards On Wall / Wood Board / Flush Mounting Using Required Clamps, Bolts, Nuts Etc., With Provision For Fixing Suitable Type Capacity Mcbs Single Phase / 3 Phase / Single Door With Powder Coated Painting. Made Out Of 14 Swg Ms Enclosure. Ii - Double Door - 12 Way Sp & N With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 75 Wiring For Lighting / Power Circuit Using One Of Fr Pvc Insulated 1100V Grade, Multistrand Copper Conductor Single Core Cable In Open Or Concealed System Of Wiring With Specified Is-694:1990 & Confirming To The Attached Gtp Of Group -A. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work A ) 1 Sqmm 76 A ) 1.5 Sqmm 77 A ) 2.5 Sqmm 78 A ) 4 Sqmm 79 Supplying And Fixing Pbbc / Bakelite Straight Or Slant Batten Holder And Wiring With 60W / 230 Volts Lamps. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 80 Supplying Patty Type Fluorescent Tube Light Fitting Of 4 -Suitable For 28 Watts Fluorescent Tube Fitting, Made Out Of M.S. Sheet And Stove Enameled With Hf Electronic Ballast , Locking Type Brass Contact Holders Mounted On Double Fold Type Sheet Base Fully Wired For Use On 230 Volts Ac . Supply Including T5 Lamp With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 81 Fixing All Types And All Capacities Of Fluorescent / False Ceiling / Spot Light / Cfl / Led Fittings Indoor On The Wall / Ceiling / Rafters / Girders Using 23 / 0.0076” Twin Twisted Pvc Insulated Wires, Required Nos Of Round Blocks And Clamps. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 82 Supplying Capacitor Type Ceiling Fan Complete With Down Rod Blades, Shackle, Canopies Etc., For Operation On 230 Volts, 50 Cycles. Single Phase Ac Supply Conforming To Iss-374-1979 And With Double Ball Bearing System And As Per Technical Data Approved. 48 Sweep ( 1200Mm ) With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 83 Fixing A Ceiling / Wall Mounting Fan Of All Capacities And All Types, With Necessary Clamps And S Hook Made Out Of 15Mm Dia Ms Rod, With 5 Amps. Ceiling Rose Of Approved Quality With Necessary Length Of 23 / 0.0076 Inch Pvc Insulated Twin Twisted Wire Of Approved Quality, Mounted On A Suitable Size Wooden Board And Wired. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 84 Extra Length Of Gi Pipe Of Class B 19Mm Dia For Down Rod. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 85 Supplying And Fixing Of Modular Switch / Socket / Stepped Electronic Fan Regulator / Dimmer / Telephone Socket Etc On Existing Modular Switch Plate As Per Is 3854 And Is 1293 Using Group A Materials Stepped Fan Regulator. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 86 Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated, Extruded Inner Sheathed, Galvanised, Steel Strip ( Except 2Cx10sq.Mm Wire Armoured ) Confirming To Is-3975:1990 ( No. Of Strip Indicated In Gtp ) & Extruded Pvc Outer Sheathed Armoured Cable With Specified Is-1554 Part-1:1988 & Confirming To The Gtp Of Group-A. 3.5 Core 35 Sqmm With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 87 Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trench Gi Pipe / Stoneware Pipe / On Wall / On Pole As Required. In Exixting Trench / Duct. 25 Sqmm To 75 Sqmm With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 88 Digging Of Trench Of 0.6M Deep X 0.50 Mtr Wide Refiling The Trench To The Required Ground Level And Consolidating Etc., Complete. ( As Per Civil Sr Ksrb I-2, P-7 ) In Soil ( Hard ) With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 89 Supply And Laying Double Walled Corrugated ( Dwc ) Hdpe Pipe Including All Necessary Connecting Sockets / Couplings / Tees / Bends / End-Caps Of Same Materials In Exisiting Trench As Per Is 14930 Part -Ii Suitable For Drawing Under Ground Cables.110Mm Od / 94Mm Id With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 90 Supplying Fixing And Wiring Earth Electrode For Grounding Of Lifts, Transformers, Dg Sets Etc Using 40Mm Dia 2.9Mm Thick 2.5 Mtr Long Gi Pipe With Gi Funnel With Mesh And Suitable Size Reducer Fixed On The Top Of The Earth Electrode. The Funnel Should Be Enclosed In A Cc Chamber Of 400X400x400mm With A Cast Iron Cover. The Earth Electrode Shall Have Staggered Holes Of 12Mm Dia And The Electrode Should Be Covered 150Mm Alround With Alternate Layers Of Salt And Charcoal From The Bottom Of The Cc Chamber. The Connection From The Electrode Is To Be Established Through Gi Strip Using Gi Bolts And Nuts. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 91 Supply And Installation / Fixing / Provision Of Pole Box With Hrc Fuse / Mcb Provision And Suitable Connector / Terminal For 3 Ph / 1 Ph Connections With Loop-In & Loop-Out Terminals For 10 Sqmm / 25 Sqmm 3.5 C Al / Ar / Cu / Ar Cable And Branch Out 2.5 Sqmm 2 Core Al / Cu Pvc Insulated Cable, Enclosed In A Thermoplastic, Polystyrene Enclosure, Which Should Be Shock Proof, Safe, Ip65 ( Weather Proof ) , Rust Proof, Dust Proof, Water Proof Having Internally Embedded Gasket With Provision For Cable Entry Through Ip65 Thermoplastic, Polyamide Glands And / Or Grommets. 260X210x116mm With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 92 Supplying And Fixing Trivector Meter Suitable For Operation Lt Operation And -Ct Operated Meter In Polycarbonate Body In Class 0.5 Accuracy As Per Is 14697 And Completely Wired. 5-20A. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 93 Fixing One Exhaust Fan In The Nitch Already Left In The Wall With Bolts And Nuts And 5 Amps. Ceiling Rose With Sufficient Length Of 23 / 0.0076 Inch Pvc Insulated Core Wire Of Approved Make. With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work 94 Supplying Of 1440Rpm Heavy Duty Exhaust Fan With Bracket Blades Suitable To Operate On 230V 50Hz, Ac Supply Complete. 12 Sweep ( 300Mm ) With All Lead And Lifts As Per The Direction Of Engineer Incharge Of Work

Key Value

Document Fees
INR 840 /-
EMD
INR 90000.0 /-
Tender Value
INR 33.50 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail