Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work excavation for foundation (for narrow excavation) in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. |
| 2 | Footings |
| 3 | Plinth Beam |
| 4 | Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officersin layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification |
| 5 | Supplying and providing Anti termite pre construction treatment using aldrin or dealdrin or heptochlor as per relavent IS 6313 (part II) code including cost of all materials, labour, hore charges for T&P etc complete. |
| 6 | Plastering with Cement Mortar 1:4 (One Cement and Four M.Sand) 20mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used and finishing, curing etc. complete complying with standard specification. |
| 7 | Supplying and filling GRAVELin \"foundation andbasement with filling sand in layers of not more than 15cm.thick well rammed watered and compacted -1m3 etc., complete complying with standard specification. |
| 8 | Supplying and filling in foundation, basement, etc with filling M.Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 9 | Plain Cement Concrete 1:2:4 (one cement, two sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers. |
| 10 | Plain Cement Concrete 1:4:8 (one cement, four sand and eight hard broken stone jelly) using 40mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers. |
| 11 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) |
| 12 | Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) |
| 13 | For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. |
| 14 | For plane surfaces such asrectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc. |
| 15 | Centering for all RCC items of work |
| 16 | Providing and laying in position, standardised concrete Mix M-20 Grade in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 17 | Ground Floor |
| 18 | Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m\") 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 19 | Foundation |
| 20 | For Ground floor |
| 21 | For First floor |
| 22 | Supplying, fabricating and placing in positionRibbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification.(Contractor has to make his own arrangements for the supply of steel and binding wire) |
| 23 | Brick work in Cement Mortor 1:5 using best quality Fly ash bricks of size 23x11x7cm for foundation and basement including curing etc.,complete complying with standard specification |
| 24 | In Ground floor |
| 25 | For First floor |
| 26 | Brick partition walls of 11.50cm thickness using best quality Fly Ash Bricks of size 23 x 11 x 7 cm in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) |
| 27 | Dadooing walls withGlazed tiles of sizes 305mm X200mm X 6mm size of approved make and quality and colour l Set in cement mortar 1:2 (one cement ,two sand) over 10 mm base layer plastering and pointing with white cement neatly as directed. |
| 28 | Supplying & fixingdoor shutters for Mediun Density Fiber Board of exterior grade 35 mm thick,single leaf conforming to IS:12406/1989 with 35x12 mm T.W.Lipping on all edges with necessary adhesives and CP screws complying with standard specifications. The rate is inclusive ofthreee coats of best quality varnish but excluding cost of furniture fittings.such as 300 mm tower bolt 2nos,200mm towerbolt I no. 300mm Aldrop 1 No. Alu handle ornamental type 2 Nos,and 1 No. Door stopper etc complete. |
| 29 | UPVC WindowSpecification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work (pwd sor p.no 65) |
| 30 | UPVC VentilatorSpecification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work. |
| 31 | Supply and fixing of PVC Solid Doors using 19gauge 19mm MS Sq,tubes for styles and frames, 15mm MS Sq.tubes for to, Lock and bottom rails. The Steel Tubes shall be covered with 5mm thick Solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in positionincluding furniture and fittings. The over all size of styles shall be 50mm X 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm X 30mm. The over all size of frames shall be 50mm X 45mm with suitable tabate for housing the shutter etc, complete as per standard specification. |
| 32 | Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (one cement and three m.sand ) 20mm thick laid in-situ and pointed with same coloured cement |
| 33 | Paving the floor with design Rajasthankotta tiles (colour and shade as directed) of size 610 mm x 610mm x 20mm in all floors over a base layer of cement mortar 1:3 (one cement and three m.sand ) 20mm thick laid in-situ and pointed with same coloured cement etc, complete as per standard specification |
| 34 | Finishing the top of slopped roof, sun-shade with Machine Pressed Ornamental Tiles of approved quality laid in cement mortar 1:3 20mm thick mixed with WPC at 2% by weight of cement used and top pointed with the same red oxide mixed mortar etc complete, complying with standard specifications |
| 35 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. |
| 36 | Supplying and erecting pull and push type Rolling Shutter with I.S.I make of approved size and section using 18 G.I sheet. The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of Hood covers, transportation charges etc (Manual Operated type upto 8 sq.m area) |
| 37 | Special Ceiling Plastering with cement mortar 1:3,10 mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306) |
| 38 | Plastering with Cement Mortar 1:5 (One cement and Five Crushed stone sand ), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 39 | Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat of over cement plastered wall surface ect., completecomplying with standard specification. |
| 40 | Providing and fixing Bitumen Pad for Expansion joint in between pavement slabs to 12mm thick and fixed as shown in the drawing including cost and conveyence of expansion joints including shalimar pad and joint sealent etc, complete as per standard specification |
| 41 | Structural Glazing:Providing and fixing structural glazing fabricated from roll formed sections made of galvanized steel colour coated (Base steel as per IS 513 of „D? quality, galvanized as per IS 277 with Zinc of 120 grams / sqm.) with total coated thickness of 0.72mm. The glass holding section made of 304 grade SS of 0.6mm thick. Galvanized steel sections are to be used as stiffeners inside the colour coated steel / powder coated sections as per the design requirement. Design calculations are made to suit wind pressures as given in IS 875. Paint specifications: Primer coat with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick. Dimensions: The section should be of 37 x 53mm for frame vertical, 37 x 53mm for frame horizontal section and section for reinforcement should be of 31 x 55mm. glass holding section should be of 37 x 37mm for top and bottom grids in between should be of 37 x 18mm as instructed by the departmental officers |
| 42 | Supplying and filling the foundation andbasement with Conveyaned Earthin layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. |
| 43 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 44 | Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. |
| 45 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete |
| 46 | Supplying and laying Rubberised interlocking Paver blockM40 grade Providing and laying of63mmthick high strength type conforming IS 15658-2006 of rubberized interlocking paver lock to required size as directed by the departmentalofficers of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with stone dust cushion below the uniform shap of approvednon skitting surface in the top and the rate including levelling the base preparation ofpavers as sub base, stone dust cushion 150mm thick layingout of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,. |
| 47 | Supplying and laying Rubberised interlocking Paver blockM40 grade Providing and laying of83mmthick high strength type conforming IS 15658-2006 of rubberized interlocking paver lock to required size as directed by the departmentalofficers of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with stone dust cushion below the uniform shap of approvednon skitting surface in the top and the rate including levelling the base preparation ofpavers as sub base, stone dust cushion 150mm thick layingout of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,. |
| 48 | Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification |
| 49 | Fabricating supplying and fixing ofPolycarbonate Sheet with the following specification. The materials should be of PPGI tile profile with a red colour or any other approved design 0.6 mm thick 24 guage having width 1050 mm. The sheet should be G.I.base pre painted hot dipped galvanized iron sheet and to be fixed with shelf tapping screws,plastic washer.The washer and screws to be fixed by using minute power machine drilled with out damaging the sheets paint coating to be regular modified polyster coat with zinc coating of Z 120 GSM paint thickness the finish should be terra cotta finish like malabar mangalore tiles finish optional matt finish. The sheet to be fixed with making suitable corrugated,cutting the sheet in to the required ssize and making ornamental designs as per the site condition and as directed by the departmental officers. |
| 50 | Supply and fixing 16amps DP switch with metal clad(side handle) of 500 V with F & N on suitable teak wood Board of size 30cmx20cmx6 cm including necessaryinternal conection,earth connection etc.,complete (SD 142) |
| 51 | Earthing as per ISI Specification with an earth electrode of 2.1mt class \"B\" GI pipe of dia not less than 40mm and with 20mm dia copper earth flat of size 125mm x50mmx6mm, with funneling arrangement using charcoat, common salt, G.I.reducer, checj nuts etc.,and mansonry workand providing RCC cover slab 38mm thick for the Brick mansory including cost of steel and fabrication of reinforcement etc., complete in all respectes as directed by the departmental officers. (SD 233) |
| 52 | Supplying and run off 8 SWG GI wire on walls or below ground level with necessary \"U\" nails, earth work excavation and refilling & including the cost of all materials etc., complete in all respects as directed by the departmental officers.(SD 75) |
| 53 | Supplying and fixing of 4 way Single phase DB of 16amps/way with 16amps DPswitch with metal glad of 500 volt(side handle) with Fuse and Neutral of suitable T.W. Board of size 40cm x30cmx6.3cm with earth connection etc., complete in all respects as directed by the departemental officers(SD 153) |
| 54 | Supplying and fixing of 8 way single phase DB of 16amps/way with 16amps DPswitch with metal glad of 500 volt(side handle) with Fuse and Neutral of suitable T.W. Board of size 40cm x30cmx6.3cm with earth connection etc., complete in all respects as directed by the departemental officers(SD 152) |
| 55 | Supplying and fixing of 5 A 3 pin and 2 pin combined flush type wall socket with 5A flush type switch concealed in suitable MS box in flush with wall and covered with 3mm thick hylem sheet (SD 135) |
| 56 | Supplying and fixing of 5 A /15A 3 pinflush type wall socket with15A flush type switch concealed in suitable MS box in flush with wall and covered with 3mm thick hylem sheet including cost of wall socket, switch and labour charges fo wall cutting, grouting, flushing and making good, painting with primary and finishing coat for MS box etc., complete as directed by the departmental officers. (SD 138) |
| 57 | Supply and fixing of 20 Amp DP Plug and socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For A.C Plug) (Legrand (MDS/Hager (L & T make) (SD 140) |
| 58 | Supplying and fixing MCB isolator 32A TP with earth connection (Legrand (MDS/Hager (L & T make) |
| 59 | Wiring with 2x1.5sqmm PVC insulated single core unsheathed copper conductor cable of 1100V grade with ISI mark confirming to IS: 694/1990 in suitable PVC rigid pipe of 1.8mm thick with ISI mark concealed in wall and ceiling with PVC accessories in flush with wall including the cost of cable, pvc pipe and specials, ceiling rose, flush type 5ams SP mark switch,PVC junction box, 16gauge MS switch box 100mm x 100mm x 75mm covered by laminated hylem sheet 3mm thick, cement, labour and making good of concealed portion with suitable colour for concealed PVC LIGHT point. (SD 18) |
| 60 | Wiring with 2x1.5sqmm PVC insulated single core unsheathed copper conductor cable of 1100V grade with ISI mark confirming to IS: 694/1990 in suitable PVC rigid pipe of 1.8mm thick with ISI mark concealed in wall and ceiling with PVC accessories in flush with wall including the cost of cable, pvc pipe and specials, ceiling rose, flush type 5ams SP mark switch,PVC junction box, 16gauge MS switch box 300mm x 200mm x 75mm covered by laminated hylem sheet 3mm thick, cement, labour and making good of concealed portion with suitable colour for concealed PVC LIGHT point. (SD 19) |
| 61 | Wiring with 2x1.5sqmmPVC insulated SC unsheated CU conductor of 1100 V grade with ISI mark confirming to IS: 694/1990 in suitable PVC rigid pipe of 1.8mm thick with ISI mark concealed in wall and ceiling with PVC accessories in flush with wall for 5 AMPS 3 PIN C.S. PLUG POINT AT CONVENIENT PLACES including the cost of cable, PVC pipes and specials, brass screws, flush type 5 amps 3 Pin C.S. plug, 16 gauge Msjoint box, 16 gauge MS switch box covered by laminated hylem sheet 3mm thick, cement, labour and making good of the concealed portion with suitable colour for open plug point. (SD 10) |
| 62 | Supply and run off 2 of 1.50sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI markconfirming to IS:694/1990 with continiousearth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wallfor mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (SD 55) |
| 63 | Supply and run off 2 of 4 sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI markconfirming to IS:694/1990 with continiousearth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wallfor mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (SD 57) |
| 64 | Wiring with 3x1.5sqmm PVC insulated single core unsheathed copper conductor cable of 1100V grade with ISI mark confirming to IS: 694/1990 in suitable PVC rigid pipe of 1.8mm thick with ISI mark concealed in wall and ceiling with PVC accessories in flush with wall including the cost of cable, pvc pipe and specials,ceiling rose, flush type 5ams SP mark switch,PVC junction box, 16gauge MS switch box 100mm x 100mm x 75mm covered by laminated hylem sheet 3mm thick, cement, labour and making good of concealed portion with suitable colour for concealed PVC staircase light point.(SD 28) |
| 65 | Supplying and fixing of 1200 mm (48\") AC ceiling fan complete with stepped electronic 300 W regulator with 1 m down rod with fan clamp, side plates and cross armof sizedepartmental officers.(SD 106)(18\") etc., complete as directed by the (SD 107) |
| 66 | Supply and fixing of20W 4 Feet LED Fitting with LED Inluding cost of materials, loading and unloading charges etc., Complete |
| 67 | Supply and fixing of 6 Metre Length Single Bracket Pole with Base Plate (250 x 250 x 6mm) 76.10mm OD x 3.65mm Thick x 6000mm LengthInluding cost of materials, loading and unloading charges etc., Complete |
| 68 | Supply and fixing of 60W LED Street Light Fitting with LED (Philips/Havells) Inluding cost of materials, loading and unloading charges etc., Complete |
| 69 | Supply and fixing of 9 Metre Length Double Bracket Pole with Base Plate (300 x 300 x 6mm) 114.30mm OD x 5.40mm Thick x 5000mm Length, 88.90mm OD x 4.85mm Thick x 2000mm Length, 76.10mm OD x 3.25mm Thick x 2000mm LengthInluding cost of materials, loading and unloading charges etc., Complete |
| 70 | Supply and fixing of 150W LED Street Light Fitting with LED (Philips/Havells) Inluding cost of materials, loading and unloading charges etc., Complete |
| 71 | Supply and fixing of 18W LED 3000K Round type resessed fittng (Philips/Havells) complete with T.W round blocks on wall or ceiling with flu tube with PVC unsheather copper leads from terminals to the filling Inluding cost of materials, loading and unloading charges etc., Complete |
| 72 | Supply and fixing of TNEB meter Board suitable for 32 A Three phase service connection with 32A fuse unit(500V)32A neutral link and earth link (1\" x 1/8\" Copper flat) on T.W plank of size 600mm x450mm x 19mm with supportingT.W.reepers of 1\" thick oneither sider with painting withsuitable bolt and nuts for fixingthe TW plank on wall withearth connection and interconnection with 7/20 PVCinsulated copper wire from EBmeter to fuse unit. SD 127) |
| 73 | Supplying and fixing 63 A TPNMC switch on suitable angle iron frame work with MS cable entry boxes with earth connection only. (SD 166) |
| 74 | Supply and run off 2 of 4sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI markconfirming to IS:694/1990 with continiousearth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wallfor mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (SD 57) |
| 75 | Supplying and run off 2 of 4 sqwmm (56/0.3) PVC insulated SC unsheatherd cu.conductor of 100 V grade on 7/20 GI bearer wire service connection mains (SD 65) |
| 76 | Supply and run of 2 of 4 sqmm (56/0.30) PVC insulated SC unsheathed cu.conductor of 1100 V grade in 25mm dia GI pipe (Class \"B\") suitably bent at both ends with necessary angle iron upright and end supports for main.(SD 70 ) |
| 77 | Supplying and fixing of 3 nos. of 100A porcelain fuse units 500 Volt of approved brand having ISI mark in T.W Board of suitable size etc., completed |
| 78 | Wiring with 2x4 sqmm(56/0.3) PVC insulated SC unsheathed Cu.Conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories, in flush with wall, with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet for 15 A 3 pin non inter locking CS plug with continuous earth wire connection with 1.5 sqmm PVC unsheadthed Cu. cable and making good of the concealed portion, with suitable colour for concealed power plug point (SD 40) |
| 79 | Supply and fixing of 32A fuse units on suitable TW board with necessary internal connections for controlling the power plug Inluding cost of materials, loading and unloading charges etc., Complete |
| 80 | Supplying and run off 4of 4 sqwmm (56/0.3) PVC insulated SC unsheatherd cu.conductor of 100 V grade on 7/20 G.I bearer wire service connection mains (SD 67) |
| 81 | Supply and run off 2 of 4 sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI markconfirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wallwith continuous earth wire connection of 14 SWG TC wire and making good for the concealed portion with suitable colour. (SD-57) |
| 82 | Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the R0.45 roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \"U\" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. |
| 83 | Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of Crushed stone sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three Crushed stone sand ) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) |
| 84 | Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works) |
| 85 | SD Tap |
| 86 | Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. |
| 87 | 20mm dia |
| 88 | 25mm dia |
| 89 | Supplying, laying and jointing PVC pipes (having working pressure 6 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. |
| 90 | 75mm dia Pipe |
| 91 | Supplying PVC Specials (with working pressure 6kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements (pwd sor p.no :102) |
| 92 | 75 mm Dia Coupler |
| 93 | 75m Dia Elbow |
| 94 | 75m Dia Tee |
| 95 | Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm \"P\" or \"S\" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings etc., complete complying with standard specifications and as directed by the departmental officers. |
| 96 | Supplying and fixing in position Indian water closet of size 580 X 440mm, white glazed earthen ware of approved quality with \"P\" trap or \"S\" trap confirming to IS:2556 -Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers. |
| 97 | Supplying and fixing in position best quality approved make white glazed earthenware wash hand basin of size 550 X 400 mm with a pair of cast iron brackets, including cost of 15mm diametre brass chromium plated piller tape,32 mm diametre C.P. Waste union, 32 mm diametre P.V.C. waste pipe with rubber plug and chain, 15mm diametre G.M.wheel valve, 15mm dia brass nipple, 15mm dia nylon connections etc., including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and paintiung the brackets with two coats of paint over a primimg coat of anticorrosive paint including testing for leackage etc., complete complying with standard specifications |
| 98 | S/F in position of Indian Make White/Colour glazed earthen ware lipped mouth Flat Back Urinal of best approved quality with G.I.Pipe connection to suitable length,32mm bell mouthed P.V.C connection ,15mm dia G.M.Wheel valve,fixing the urinal to the wall in positionwith necessary T.W.plugs ,clamps,screws, shellac etc.,including dismantling masonry if necessary and redoing the same to original condition ,fixing the 15mm dia. G.I.pipe connection and wheel valve ,painting the pipe with two coats of approved paint over one coat of primer and checked without any leakage complete, complying with standard specifications. -(D) |
| 99 | Supplying and fixing in position SFC Manhole covers (light or heavy duty) mof various sizes of best approved quality and as per atandard specifications etc.,complete of size 60 x 60 cm |
| 100 | Supply, delivery and fixing of 10000lit Capacity HDPE tank as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc., |
| 101 | Investigation charges for Geophysical survery finding of yeild to the point drilling of Borewell for all etc., complete |
| 102 | Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( Site will be shown by the TWAD Board Officers) including construction of mud pit. |
| 103 | Upto 60m |
| 104 | 60 to 90m |
| 105 | 90 to 120m |
| 106 | 120 to 150m |
| 107 | 150 to 180m |
| 108 | 180 to 210 |
| 109 | 210 to 240m |
| 110 | 240 to 250m |
| 111 | Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the TWAD Board Office |
| 112 | Upto 60m |
| 113 | 60 to 90m |
| 114 | 90 to 120m |
| 115 | 120 to 150m |
| 116 | 150 to 180m |
| 117 | 180 to 210 |
| 118 | 210 to 240m |
| 119 | 240 to 250m |
| 120 | Supply and delivery of 200mm dia PVC Casing Pipe (CM - Casing Medium depth) as per IS 12818/2010 including loading and unloading charges etc., complete |
| 121 | Charges for developing the Borewell with air compressor of 600 CFM capacity (Minimum 8 Hours) including transportation, labour and fuel charges for compressor as directed by TWAD Officers and conducting yield test by \"V\" notch method. |
| 122 | Supply and delivery of 10HP Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately). |
| 123 | Supply and delivery of clear water vertical wet type submersible pump suitable for 100mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continuos rated two pole suitable wet type vertical squirrel cage induction motor as per IS 9283 /1995 and as amended there after, suitable for operation in AC three phase (415 V+/- 10 %, 50 HZ +/- 5 % 75 x 125) including loading and unloading charges etc., complete |
| 124 | Labour Charges for the erection of Submersible pumpset in borewellincluding fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps,and erection of panel board consisting of TPICN swtiches starter voltmetre, Ammeter, three point (indicating) lamps capacitor single phasing preventor and laying and jointing the cable and twin earthing for etc., Complete and testing the pumpset and trail run for 10 days |
| 125 | Supply and delivery of Electric Monoset centrifugal pump conforming to IS 9079:2002 as amended from time to time, with CI FG 200 Casing , hydraulically and dynamically balanced Bronze grade LTB-2 impeller, impeller ring and casing ring, stainless steel shaft capable of discharging required quantity of water against a total head noted below due to all causes. Pump shall of BEE 3 Star Rated and capable of discharging the specified quantity at the head noted at the minimum NPSHA at site conditions. The shut off head shall be atleast 25% over and above the head at duty point. The pump shall be suitable for operation in AC three phase , 415 V+/- 10% , 50 Hz +/- 5%. Squirrel cage induction motor for continuous operation. The speed of the Pump and Motor shall be not less than 2700 to 2900 RPM respectively including loading and unloading charges etc., complete |
| 126 | Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately). upto 5HP |
| 127 | Supplying and fixing 12\" (30cm dia) light duty Exhaust fan including cost of all materials,labour, lead, lift, etc complete (SD 114) |
| 128 | Construction of Inspection chambers of following sizes with earth work excavation for foundations,C.C 1:4:8 using 40mm HBGS jelly for foundation and brick work in CM 1:5 using country bricks 9\" x 4 3/8\" x 2 3/4 \", inside plastering with CM 1:3 12mm thick, inside channeling with brick work, outside plastering with C.M 1:3 20mm thick, R.C.Cprecast cover slab 75mm thick using M20using 20mm blue granite jelly with necessary reinforcement etc complete as directed by the departmental officers (1.5X0.90X1.50) |
| 129 | Providing of Granular Sub Base using Grade I materials of table 400-1 of MORTH with minimum CBR 30 spreading in uniform layers with motor grader on prepared surface, mix in by place method at OMC and compacting with Vibratory Roller to achieve the desired density including all labour charges etc complete as per technical specification and as directed by the departmental officers - MORTH Rev V No. 111, 112, 401, 900. |
| 130 | Providing and Laying, Spreading and Compacting graded stone aggregate to Wet Mix Macadam (WMM) specification including premixing the materials with water at OMC in mechanical mix plant carriage to mixed material by tipper to site laying in uniform layers with paver in sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per clause 406 of MORTH Specifications. |
| 131 | Providing and laying prime coat over WBM / WMM surface using 7 Kg of Emulsion Bitumen (SS1) per10 sqm for preparatory to another bituminous construction over it, including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as per Clause 502 of MORTH Rev-5 |
| 132 | Providing and laying tack coat over WBM / WMM surface ( treated with primer ) using 2.50 Kg of Bitumen Emulsion ( RS1 ) per 10 sqm for preparatory to another bituminous construction over it, including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as per Clause 502 of MORTH Rev-5 |
| 133 | Providing and laying50mm compactedthick bituminous macadamusing 0.42 cum of 26.5-11.2 mm graded metal, 0.10 cum of 11.2-2.8 mm graded metal and 0.18 cum of 2.8 mm & below with 38 kgs ofbitumen per 10 sqm for premixing including cost and conveyance of all materials toC M P site,heating the bitumen and agregates to the required temperature in central hot mix plant 20- 30 tonnes capacity conveying the mix by tipper trucks to paver site,spreading the mix in required temperature for uniform thickness of 50 mm with mechanical paver to the specified grades and cross sections and compaction byVibratory roller tothe required density etc., including labour for loading bitumen in to bitumen tank and metal to feeder unit,labour for attending to paver site etc., including hire charges and fuel charges for 20-30 tC M P with bitumen boiler,tipper trucks,paver finisher, power rollers and all other tools and plants required,includingall other incidental charges etc.,complete as per specification using C M P clause 504 of Morth specifications. |
| 134 | Providing and Laying Bituminous Concrete 40mm thick using 0.13cum of 19-9.50mm graded metal and 0.17cum of 9.50-2.36mm graded metal and 0.26cum of 2.36mm & below metal with 45.27 Kgs of 60/70 bitumen & 5.03 Kgs of Plastic Waste (Total = 50.30 Kgs) and for premixing per 10 sqm including cost and conveyance of all materials to CMP site, heating the bitumen and aggregates to required temperature and mixing them in required temperature in central hot mix plant 20 - 30 tonnes capacity conveying the mix by tipper trucks to paver site, spreading the mix in required temperature for uniform thickness of 40mm / 30mm with mechanical paver to the specified graded and cross sections and compaction by vibratory roller to the required density etc., including labour charges for loading bitumen in to bitumen tank and metal to feeder unit, labour for attending to paver site etc., including hire charges and fuel charges for 20 - 30 tonnes CMP with bitumen boiler, tipper trucks, paver finisher, vibratory rollers and all other tools and plants required including all other incidental charges etc., complete using CMP clause 507 of MORTH Rev-5 specifications. |
| 135 | Providing and laying of hot applied themoplastic compound 2.5mm thick including reflectorsing glass beads at 250gram/sqm area thickness of 2.5 mm is exclusive of surface applied glass beads as IRC 35.The finished to be level uniform and free from streaks and holes etc. complete as per MORT and H specification no. 803 |
| 136 | Providing and fixing of road stud 100 x 100mm diecast in aluminium ressistance to corrosive effect of sait and grift fitted eith lenes reflected instaled in concrete or asphalts surface by drilling hole 30mm upto a depth of 60mm and beded in a suitable bitumens grout are epoxy mortar etc., complete as per BS (part) 1973. |
| 137 | Providing anderectingof Directionand PlaceIdentification Retro-reflectorised Sign made out of High Intensity PrismaticGrade Sheeting confirmingto Type-IVstandards of IRC-67: 2012 and ASTM D 4956 —09, specification and fixed over 2mm thickAluminium sheet fixed over a back supporting frame of 25mmx25mmx3mm Mild Steel angle and supported on a mild steel angle post 75X75X6mm with a clearheightof notlessthan 2.10mfromthe groundlevelto the bottom of the sign board and 0.6Ombelowgroundlevel.The sign postshouldbe painted as per IRC67-2012 and firmly fixed to the ground by means of properly designed foundation withM15gradecementconcrete45cmX45cmX60cm sizeincludingcostand conveyanceof all materials, equipment, Machinery and labour with all leads andlifts,loadingcharges necessary for satisfactory completion of the work as directed by the engineer in charge. High intensity Retro Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.6 of IRC 67-2012. The retro- reflective sheetingshallbecoveredunder7year warranty issued for field performance anda certified copy of three years outdoor exposure report shall be obtained as per IRC 67:2012. (as per MORT&H Specification No.801) |
| 138 | Supply and fixing of Stainless chair and Back seat made of 1.2mm thick stainless steel of 201 grade.• Arm and leg made of 1.1 mm thick stainless steel of 201 grade.• 1.2mm powder coated mild steel beam below for superior support.• Individual seat and back width of 520 mm.3 Seater |
| 139 | Supplying and erecting in position of following liters capacityIndustrial Model Reverse Osmosis Water-cum-Purifier to deliver Potable Water with World Health Organisation (WHO)Standards with following accessories. (a) MS Skid - 1 No.(b) Media 11054 No. Vessel with 20 nb Multiport Valve (withMedia Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No.(e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic(USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No., LowPressure Switch - 1 No., LevelSwitch - 1 No. & NecessaryCPVC Pipes and Fittings. The system shall be provide with Two Panel Control Systemwith necessary Stainless Valves and Fittings and Float Controletc. The rate should be inclusive of all civil works, wherevernecessary to install the System in position and intact.(250 Litres) pwd sor pg no 72) |
| 140 | Supply and erection of 120KW Solar On Grid Solar Rooftop System from Go Solar Solutions consists of following components.Make : Canadian Solar/Vikram SolarType : Poly-crystalline Power: 315/320/325/330 Wp (According to Availability)Quantity: 158 No Size : 2000mm x 1000mm (2 meters x 1 meters) Voltage : 440/220Volts On Grid Solar Inverter Make : Delta Inverter (German) Size : 50kW Phase : Three (3 Phase) Quality : Premium Quantity : 1 Unit Output : 440/230 Volts @ 50Hz Monitoring System : Yes (DelREMO-Delta Realtime Monitoring) Type : ifi/Lan/GSM Mobile Apps : Yes Electrical Accessories (Compulsory) DC Distribution Box: Yes (Fuse+Surge Trap+MCCB Breaker) AC Distribution Box: Yes (Fuse+Surge Trap+MCCB Breaker) Mounting Structure: Type : Aluminium or Galvanized Angle : As per site requirement, Design : Customized Wiring & Cabling Make : Polycab, Material: Copper Size : 6mm2 Solar Power Output (Generation) Units per Day: 225 kWh Units Per Month : 6750 Units Units Per Year : 72,500 Units DC Side: Armoured Cable |
| 141 | Supplying and erectingof 20 Mtrs. High Mast Tower Polygonal Shapes. Suitable for 12 luminaries for Wind Speed up to 180 Km/hr. As per IS -875 Parts -3 Material Cons.: BSEN 10025 # Mechanical Components including Head Frame & Pulley Assay, Winch Bracket, Lantern Carriage Ring, Luminaries and C.G Box Mtg. Arms, Resting Bracket Guide Ring, Compensating Disc, Lightening Arrestor.etc. ( Each Set ) # Wire Rope, Safety Wire Rope, D Suckle Clamps, Nuts and Bolts. # Cable with termination & distribution box. # Foundation A0.45essories. # Winch Assembly # Power tool. Mast bottom Dia:415 mm. Top : 150 mm, Thk: 4,3,3 mm. Motor-1.Feeder pillar box comprising 100 ams fuse unit 24 hours timer 1-nos and contactor 1-nos outgoing MCB toggle switch and neutral link with internal wiring made of MS sheet and vermin proof.Erection and commissioning of 20 Mtr high mast on the above said concrete foundation using suitable equipments.Fixing of flood light luminaries in the lantern carriage including internal wiring & using flexible copper cable complete |
| 142 | Supply fixing and errection of CCTV Camara including cost and Conveyance of all materials to site etc complete as per Specification |
| 143 | CCTV Camera (Q) |
| 144 | Network Video Recorder (32 CHANNEL-2 SATA) |
| 145 | Hard disc for NVR 4TB |
| 146 | 24 Port Patch Panel |
| 147 | Rack With Accesssories -436 U RACK |
| 148 | Armoured LAN & CCTV Cable (CAT-6) |
| 149 | Led tv for display (Q) 42\" LED TV |
| 150 | Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. |
| 151 | Supply and delivery of First Aid Box complete with all First Aid Medicines all Including all charges etc., complete |
| 152 | Supply and delivery 4 Nos of Fire Buckets made out of 40x40x6mm MS Angle Including all charges etc., complete |
| 153 | Supply and fixing of Water CO2 Stored Pressure Type 9 litres capacity Fire Extinguisher as per new IS 15683 complete with control valve, gun metal cap, pressure gauge, operation sticker, discharge hose, wall mounting bracket, safety clip, etc., as directed by the Departmental Officers |
| 154 | Supply delivery erection ,testing and commisioning of 100 KVA capacity Deisel Generator set 3 ph, 50 Hz,415 V, consisting of deisel engine capable of delivering continuous brake horse power with standard fittings,water cooled radiators,acoustic closureto restrict the noice level as per the KPCB norms,residential silencer with exhaut pipe arrangement (insulated with glass wool imside thwe building ) upto outside of the roomabove roof level,suitable alternator (brushless),self excited,self regulated, suitable for continuous operation .Standard cntrol panel, consisting of ameter with CTs and selector switch, Voltmeter with selector switch, M0.45B, energmeter,earth fault relay,indicating lamps,fuses and required1.1 KV grade PVC armoured aluminium cable from alternaor to alternator control panel, 12/24 Vbattery, batteryleads, battery chrger ..etc. Coupling with gaurd ,fuel tank (8Hrs. capacity) common rigid MS channel baseframe, antivibration mounting pad etc., complete |
| 155 | supply,erection,testing and commissioning of following indoor type 11KV/433V cast resin dry type transformer inclding all asssesories and componenets as required.rate shall be inclusive of transportation,bottom mounting,minor civil works,foundations and test etc. 1000 KVA (PWD SOR Annexure XIII Part M , 1-D P.NO 140) |
| 156 | Supplying , Fixing and Commisioning Passenger Information Display Its Controller Unit With GPRS/GPS Modem with 3G Support, PIS-Stop announcements Based on GPS Co ordinates and Displayin internal LED Boards , Route Display in External Display Boards, Route Selection Option Thro Driver Display. Building Amblifier for bus stop And Driver Announcements, Building 4 Channel DVR-Support 4 x Cameras,USB interface For Downloading Video Data And Uploading Route Info Messages Etc,. External GPS Antenna, IP54 Enclosure with Industrial connectors, 7\" Touch Screen Driver Display (IP 54), Microphone 4 Speakers, PANIC Button, Survilence Camera 2 Nos Internal,. including all Materials of Loading, unloading, Transporting and All Labour Charges etc,. Complete. |
| 157 | Supplying , Fixing and Commisioning Variable Message Display Full colour RGB LED Display, Outdoor, Water Proof, Day & Night Visible VMD P8 SMD Pitch mm,(6 ft x 10 ft) of Size, 384 x640 LED Matrix Resolution, 6000-6500 of Brightness Cd/m2, 3g/4G GPRS Control System For VMD, Including Unipole Structure,Civil Work and Installation with Electrical Power Supply Wiring & all Materials of Loading, unloading, Transporting and All Labour Charges etc,. Complete |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail