Repair / Replacement / Maintenance Of Street And Solar Light Poles, Ug Cable Links, Feeder Piller And Allied Works At Nausena Bagh And Nofra Under Ge Navy Porbandar, porbandar-Gujarat

Military Engineer Services-MES has published Repair / Replacement / Maintenance Of Street And Solar Light Poles, Ug Cable Links, Feeder Piller And Allied Works At Nausena Bagh And Nofra Under Ge Navy Porbandar. Submission Date for this Tender is 05-08-2022. Feeder Pillar Tenders in porbandar Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

32950970
Corrigendum : Repair / Replacement / Maintenance Of Street And Solar Light Poles, Ug Cable Links, Feeder Piller And Allied Works At Nausena Bagh And Nofra Under Ge Navy Porbandar
Open Tender
Indian
Gujarat
porbandar
05-08-2022

Tender Details

Repair / Replacement / Maintenance Of Street And Solar Light Poles, Ug Cable Links, Feeder Piller And Allied Works At Nausena Bagh And Nofra Under Ge Navy Porbandar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Jul-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-08-2022
2 02-Aug-2022 Corrigendum Date 05-08-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 48000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR / REPLACEMENT / MAINTENANCE OF STREET AND SOLAR LIGHT POLES, UG CABLE LINKS, FEEDER PILLER AND ALLIED WORKS AT NAUSENA BAGH AND NOFRA UNDER GE NAVY PORBANDAR
Sl. No. Item Description
1M & L for servicing of LT panel including dismantling the old cable lugs of any size by cutting the cable including fixing of new lugs by pealing the cable, cutting and jointing the cables with the help of Cable Joint Kit of suitable size if required, servicing of MCCBs/MCBs/Bush Bar/ Checking/Replacing of Nut Bolts etc. cleaning of all joint make joint Carbon free and remove rusted part by chemicals all as specified and directed by Engineer in Charge. Note: i) The items i.e. MCCBs/MCBs, Cable Joint Kit of suitable size shall be measured and paid seperately under various item. ii) The material and labour required for servicing of LT panel i.e consumables/nut bolts etc shall be deemed to be included in the item rate.
2Preparation of old treated surfaces of LT pole by scrapping with brushes, emery paper 9m / 11m long PCC or steel tubular with all connected channel, cross arms caps etc applying one coat of aluminium paint over a coat of anti rust paint as a primer on steel surfaces and two coats of synthetic enamel paint upto one meter above the starting point in black & yellow strips 30 cm each on concrete surfaces and silver colour on steel surfaceincluding numbering by using white paint over a surface of black paint base of size 15cm x 15cm complete all as specified and as directed by Engineer-in-Charge.
3Street light fitting bracket, 1.5 mtr long made of galvanized iron pipe of 32mm bore light grade complete with nut, bolts, washer etc inclusive of one primer coat, one under coat and one finishing coat of silver paint fixed in repair / replacement complete all as specified and directed.
4Street light fitting bracket, 1.5 mtr long made of galvanized iron pipe of 40mm bore light grade complete with nut, bolts, washer etc inclusive of one primer coat, one under coat and one finishing coat of silver paint fixed in repair / replacement complete all as specified and directed.
5PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in mass concrete / foundation of pole including necessary use and waste of form work complete all as specified and directed.
6PCC 1:5:10 type E2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete or as in sub base complete all as specified and directed.
7PCC 1:2:4 type B-1 using (20mm graded crushed stone aggregate)in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, Benching, kneelers, apex stones, bed plates, kerbs, saucer drain(including finishing top surface of drain even and smooth without using extra cement), water troughs and the like including weathering, slightly rounded or chamfered angles and throating,and similar work including use & waste of necessary form work complete all as specified and as directed.
8Taking down the High Mast light of any heightincluding bracket by the means of crane and reinstallation to site after repairing work with help of high-capacity Hydraulic crane complete all as specified and as directed.
9Old rusted pulley assembly of specified dimensions at top and bottom, the material for pulley must be anti-corrosive fixed in repair / replacement complete all as specified and directed.
10Stainless steelwire ropespecified dimensions and strands for lifting up Light bracket fixed in repair / replacement complete all as specified and directed by Engg-in-charge.
11Complete rewinding of Electrical motor upto1-2 HP capacity including changing bushes bearings of all required accessories complete all as specified and directed.
12Flood Lights holding bracket for hight mast light of any tpe of High mast including all fitting accessories fixed in repair / replacement complete all as specified and directed.
13Foundationbolts and Nutsand studs fitting suitable for existing High mast light 12-16Mtr height all as per specified diamensions high mast light fixed in repair / replacement complete all as specified and directed.
14Painting oftwopole strucure including of 11 mtr HT electric tubular/ PCC pole with two coat of off white distemper colour after cleaning, scraping and all iron structure by silver colour complete by skilled painter with marking complete all as directed and specified.
15Stone aggregate of size 40 mm to 100 mm and laid in 4 pole structure and two pole structure including cleaning bushes from grass root and making good surface before laying of stone aggregate complete all as directed by Engg-in-charge.
16Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for HT 20x15cm size fixed in repair / replacement complete all as specified and directed.
17Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for HT 25x20cm size fixed in repair / replacement complete all as specified and directed.
18Taking up/out old U/S XLPEinsulated screened. PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking up Old concrete cable cover from trenches/walls/ceiling/poles etc any size all as specified and directed
19Supply, laying and fix of Cable laid in trenches, passing through pipes and fixed on wall/floor/ceiling with proper saddles , including testing of XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of following size 95 sq mm 3 core fixed in repair / replacement complete all as specified and directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it. 2. The excavation, earth work, sand cushioning and brick protection etc will be measured and paid separately under respective items
20Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 10 sqmm 4 core suitable for working on 1100 Volts, confirming to IS-1554 laid in tranches, in floor, in ducts, through pipe or along pole fixed in repair / replacement complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipeshall be measured and paid for separately.
21Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 16 sqmm 4 core suitable for working on 1100 Volts, confirming to IS-1554 laid in tranches, in floor, in ducts, through pipe or along pole fixed in repair / replacement complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipeshall be measured and paid for separately.
22Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 25 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-1554 laid in tranches, in floor, in ducts, through pipe or along pole fixed in repair / replacement complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipeshall be measured and paid for separately.
23Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 35 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-1554 laid in tranches, in floor, in ducts, through pipe or along pole fixed in repair / replacement complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipeshall be measured and paid for separately.
24Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 50 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-1554 laid in tranches, in floor, in ducts, through pipe or along pole fixed in repair / replacement complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipeshall be measured and paid for separately.
25Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 70 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-1554 laid in tranches, in floor, in ducts, through pipe or along pole fixed in repair / replacement complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipeshall be measured and paid for separately.
26Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 120 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-1554 laid in tranches, in floor, in ducts, through pipe or along pole fixed in repair / replacement complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipeshall be measured and paid for separately.
27Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 185 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-1554 laid in tranches, in floor, in ducts, through pipe or along pole fixed in repair / replacement complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipeshall be measured and paid for separately.
28Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 240 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-1554 laid in tranches, in floor, in ducts, through pipe or along pole fixed in repair / replacement complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipeshall be measured and paid for separately.
29Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 400 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-1554 laid in tranches, in floor, in ducts, through pipe or along pole fixed in repair / replacement complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipeshall be measured and paid for separately.
30Galvanised tubing light grade 50 mm for cable protection, laid under plints / floors / roads / paths / culverts of fixed on walls or concealed in walls or along the steel poles by means of M.S.F.I. clamps with necessary bolts nuts washers complete all as specified and as directed.
31Galvanised tubing light grade 80 mm for cable protection, laid under plints / floors / roads / paths / culverts of fixed on walls or concealed in walls or along the steel poles by means of M.S.F.I. clamps with necessary bolts nuts washers complete all as specified and as directed.
32Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation of Pole, laying of cable and getting out in hard dense soil complete as specified and directed.
33Returning, filling in any type of soil including spreading, levelling, watering and well ramming in layers not exc 25 cm in soil complete all as specified.
34Removing of excavated materials n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
35Unreinforced precast concrete cable cover, ISI marked class LV types 1 flat size 250mm x 150mm x 40mm having minimum average breaking load 200Kg, complying IS:5820-1970 made of concrete used of grade M-20, laid flat in trenches over the cable with the length of concrete cover perpendicular to the direction of the cable length, adjacent / abutting each other complete all as specified.
36Unreinforced precast concrete cable cover, ISI marked class HV types 1 flat size 300mm x 180mm x 40mm having minimum average breaking load 200Kg, complying IS:5820-1970 made of concrete used of grade M-20, laid flat in trenches over the cable with the length of concrete cover perpendicular to the direction of the cable length, adjacent / abutting each other complete all as specified.
37Sand cushioning with a layer of sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed.
38Cable jointing kit for 11KV (Earthed) grade cable for outdoor end termination, heat shrinkable type complete with jointing material and accessories suitable for 3core XLPE armoured aluminium conductor cable of size 95 sqmm fixing complete all as specified and as directed.
39Supply and fixing cable jointing STRAIGHT THROUGH JOINTfor 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5core XLPE armoured, alluminum conductor cable of size 70 to 185 sq mm and all as directed by Engineer-In-Charge. Make :- 3M/RAYCHEM/CAMPAQ
40Supply and fixing cable jointing STRAIGHT THROUGH JOINTfor 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5core XLPE armoured, alluminum conductor cable of size 240 to 400 sq mm and all as directed by Engineer-In-Charge. Make :- 3M/RAYCHEM/CAMPAQ
41Hot press moulded SMC junction box 240mm x 130mm x 95mm (inside dimension) fixed with left side hinges and cable terminals with one number 6 Amp SP MCB fixed to pole with clamp nuts,bolts etc complete all as specified anddirected by Engineer-in-charge.
42Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and 102mm x 279mm at bottom,class 10 including removing old PCC pole fixed in repair / replacement complete all as specified and directed by Engr-in-charge.
43Supply and fixingLED street light fitting 70/72 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
44Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole all as specified and directed by Engr-in-charge.
45Driver of capacity 70-150 Watt, LEDslamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection packingfixed in repair / replacement complete all as specified and directed by Engr-in-charge.
46Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured,electric controlcables (Heavy duty) with strandedcopper conductor of size 1.5 sq mm 3 core 1100 volts grade complete all as specified and directed.
47Supply and fixing switch air break gang operated out door type HT 11 KV triple poles 200 Amps air break fittings type with fixed contacts of phosphorus bronze and moving contacts of copper with mechanically operating from ground level vertical mounted completed with HT insulator on steel frame operating rod made out of 25mm GI pipe medium grade worked from ground level with handle and locking arrangement with 12 insulators with drop out fuses with test fixed in repair / replacement complete all as specified and directed.
48FIRE FIGHTING POINT at electric installations made out of brick masonry foundation of specified size with iron angle and MS sheet strucure of specified diamentions duly painted with red oil bond colour andwriiten of FIRE POINT by white colour includding 2 fire bucket and 3 Fire extingusher chemicals ABC powdertype 5-6kg , Co2 type 6 kg, Fire ball of suitable capacity fixed in repair / replacement complete all as specified and directed by Engg-in -charge.
49Supply and fixing lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable of 11000 Volts, fixed in repair / replacement complete all as specified and directed.
50Single dome LED aviation obstruction light comprising of aluminium housing with polycarbonate enclosure with accessories fixed in repair / replacement complete all as specified and as directed. Make Bajaj/ Crompton or eqivalent.
51LED flood light 350W , with powder coated pressure die cast aluminium housingpowder coated andtoughened glass clear glass fixed with SS screw, with secondary lens optics with LED having luminaire efficacy of 130 lm/W. Total of 26,000 Lums +/- 10%. Provided with built in surge protection 5kv and external surge protection of 10kv, having Ingress protection Ip66 fixed in repair / replacement complete all as specified and directed. Model:- Crompton/ Havells/HPL
52Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level Galvanised earth plate connected with GI wire 04mm dia by means oflug, bolts, nuts, check nuts, washers of galvanised iron GI protection pipe 15mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipemedium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover including testing on completion complete all as specified and directed.
53Earthing continuity galvanised iron strip 32 x 6 mm or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situationfor loop earthing etc as required all as specified and directed by Engr-in-Charge.
54Servicingandoverhaulving of ACB upto 1600 Amps Capacity including allconsumables maintainance kit and required minor partsincluding dismantling the old cable lugs of any size by cutting the cable including fixing of new lugs by pealing the cable all as specified and directed by Engineer in Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail