Project Description

Provision Of Armoury At Air Force Station Palam Under Ge ( P ) Af Gurgaon

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 09-Jul-2022 Corrigendum01 BOQ 26-Jul-2022
2 15-Jul-2022 Corrigendum02 BOQ 26-Jul-2022
3 18-Jul-2022 Corrigendum03 BOQ 26-Jul-2022
4 19-Jul-2022 BoQ BOQ 26-Jul-2022
5 19-Jul-2022 Corrigendum04 BOQ 26-Jul-2022
6 26-Jul-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-Aug-2022

BOQ

Name of Work: PROVN OF ARMOURY AT AIR FORCE STATION PALAM UNDER GE (P) AF GURGAON
Sl. No. Item Description
1Note:- All items pertains to Lum Sum portion of Building works as per complete drawings are included with this BoQ and building shall be excetuted as per drawiings and item included in BoQ.
2Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m complete all as specified and directed
3Exacvating in trenches excavation 1.5m wide and exacavting 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, etc, and excavation 10sqm on plan and 1.5 in depth and getting out etc. complete all as specified and directed by engineer in soft /loose soil.
4Supplying and filling in plinth, under floor & foundations and sand cushioingetcwith sand , including watering, ramming, consolidating and dressing complete all as specified and directed.
5Supply & Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (Chlorpyriphos/ Lindane emulsifiable concentrate of 20% in sealed containers) for Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area With Chlorpyriphos/ Lindane E.C. 20% with 1%concentration complete all as specifed and directed.
6Supply & Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (Chlorpyriphos/ Lindane emulsifiable concentrate of 20% in sealed containers) for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration complete all as specifed and directed
7Supply & Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (Chlorpyriphos/ Lindane emulsifiable concentrate of 20% in sealed containers) for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surfaceWith Chlorpyriphos/ Lindane E.C. 20% with 1% concentration complete all as specifed and directed
8M& l for Hardcore of gauge exc 63 mm and n exc 100mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered andrammed to a true surface complete all as wspecifed and direcyted.
9Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point
10Providing and laying in position cement concrete of in foundation, filling and mass concrete, sub-base to flooringType D2, 1:4:8 ( 40 mm graded aggregate ) complete all as specifed and directed
11M&L for cement concrete in foundations, filling and mass concrete 1:3:6type C2 using 40mm graded stone aggregate complete all as specified and directed.
12Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete M-25 (20mm graded Aggregates) in foundation, including rafts, footings, foundation beams, plinthbeams, bases for columns, etc, basement slab, under rimmed piles and mass concrete.work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairingstrength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishingand reinforcement as per direction of the engineer-in-charge
13Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete RCC, M-25 (20mm graded Aggregates) slabs supported on walls, beams and column in floors, roof, landings, balconies, canopies, deck slabs and in shelves and the like work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge
14Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete RCC, M-25 (20mm graded Aggregates) beams, cantilevers, bressumers, lintel over 1.5 mt span work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge
15Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete RCC, M-25 (20mm graded Aggregates) column, pillars, piers, posts and struts work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge .
16Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete RCC, M-25 (20mm graded Aggregates) chajjas work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge
17Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm Soft soil/loose soil
18M& L for 10 mm above Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing cracking, bending soirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.9 mm dia or securong with clipscomplete all as specifed and directed.
19M& L for 6 to 8 mm Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing cracking, bending soirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.9 mm dia or securong with clipscomplete all as specifed and directed.
20M& L for 5 to 10 mm in striuups Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing cracking, bending soirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.9 mm dia or securong with clipscomplete all as specifed and directed.
21Providing and laying autoclaved aerated cement blocks(grade-1 as per IS 2185 with compressive strength not less than4 mpa) masonry straight or curved on plan exc 6m with200mm thick AAC blocks in below plinth andabove plinth level up to floor V level built in Cement mortars 1:6all complete as per direction of Engineer-in-Charge.Note: The contractor shall submits the test certifcate before sample approval to GE.
22Providing and laying autoclaved aerated cement blocks (grade-1 as per IS 2185 with compressive strength not less than4 mpa)masonrywith 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 8 mm dia TMTbars at every third course of masonry work.Note: The contractor shall submits the test certifcate before sample approval to GE.
23Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 marble chipping 5 to 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water (mixed with H2SO4 @ 5% scrubbing and washing shall continue till the stone chipping are sufficiently exposed to its natural colour)to expose the stone chippings .complete all as specified (Payment for providing grooves shall be made separately).
24Material and labour for Rendering 05mm thick on concrete surfaces in cement mortar 1:3 finished even and smooth without using extra cement to RCC ceiling, chhajjas, roof projection,fascia,fins,parapet, waist slab on RCC staircaseetc and similar likes at any height including necessary scaffolding, ladder, formworkcomplete all as specified and directed.
25Material and labourapplying two coats of Oil Bound Distemper over a coat of alkali resistant primer including preparation of newly plasteredwall surfaces complete all as specified and directed.
26Material and labour for Preparation of new plastered surfaces of ceiling and applying three coats of white wash complete at any height including necessary scaffolding all as specified and as directed.
27M&L for Painting with synthetic enamel paint of approved brand and manufacture to give an even shade on steel Surfaces of any description, over 10cm in width or girth,not otherwise described over red oxide zinc chrome primer incl preparation complete all as specified and directed.
28Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying two coat of synthetic enamel paint over a priming coat of approved steel primer incl preparation comple all as specified and direcetd
29Supply and fixing 1.25mm thick press steel frames for doors with single rebates of size 105 x 60 mm including necessary fixing lugs, hinges, lock strike plate,includig tarring back of chowkhat & hold fasts and filling withcement concrete 1:3:6 type C-0 complete as specified and directed.
30Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge.
31M&L for Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats 30 mm (1st class hardwood)
32M&L for Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
33M&L for Factory made soild PVC profiled panel door shutter 28mm thick with integral skin as frame & 3mm thick high pressure compact laminate on both side of approved colour as infill, with \"C type Gl or 40 x 20 x19 of MS pipe as stiffner & supplying & fixing in frame at site as per specifications & drawing
34Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per specified and directed. (Glazing, paneling to be paid for separately) :
35(A) For Frame : Powder coated aluminium (minimum thickness of powder coating 50 micron)
36(B) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required : Powder coated aluminium (minimum thickness of powder coating 50 micron)
37Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per specified and directed. . (Cost of aluminium snap beading shall be paid in item no. 1.101) : 5.5mm thick sheet glass of ordinary quality
38M&L for PCC 1:2:4 type B2 using 40mm graded stone aggregate as in surface channels and drains complete all as specified and directed.
39Material and labour for Machine cut kota stone flooring 20-25 mm thick(size of kota stone slab not less than 55cm X 55cm)laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to mirror finish laid over and including 20 mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes and and including 25mm thick cement conrete type B-1, 1:2:4(12.5mm graded aggregate complete allas specified and as directed.
40Material and labour for Machine cut kota stone 18-25 mm thickas in riser and treads of steps,skirting,dadoincluding rubbing and polishing to mirror finish over and including 10mm thick backing plaster in CM 1:4 & roughening to conctere/terrazo surfaces and brushing the surfaces with neat cement slurry @ 3Kg/Sqm complete allas specified and as directed.
41Material and labour for First quality Non-skid Ceramic coloured tiles jointless, 7-8 mm thick (area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm) laid in floors with neat cement slurry @ 3Kg/Sqmover and including 15mm thick screed bed of cement mortar (1:6) andincluding pointing in white cement with pigment to match the shade of tiles including dismantling of floor, hearth or wall tiling including cemetn mortar bedding complete all as specified and directed.
42Material and labour for First quality Glazed ceramic coloured tiles in vertical surface of 7 to 8mm thick set and jointed in neat cement of requiredshape and size as in skirting/dado etc set and jointed in neat cement slurry over & incl 10 mm thick rendering in CM 1:4 and pointed in white or coloured cement to matchincludingdismantling of floor, hearth or wall tiling including cemetn mortar bedding complete all as specified and directed.
43Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
44M&L for Centering and shuttering including strutting, propping etc. and removal of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed
45M&L for Centering and shuttering including strutting, propping etc. and removal of Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed
46M&L for Centering and shuttering including strutting, propping etc. and removal of Formwork to Formwork to staircases with sloping or stepped soffits including risers and stringers (excluding landing) complete all as specified and directed
47M&L for Centering and shuttering including strutting, propping etc. and removal of Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed
4840mm thick brick tiles laid on mud mortar and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on mud phuska
49Wire brushing and cleaning topsurface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc., and surface painting, with a layer of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq. m, blinded with grit or pea size gravel @ 0.006 cu.m per sq.m, and lightly tampered (area of flashings, etc., shall be added to the roof area)
50Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid (W.C. pan with ISI marked white solid plastic seat and lid), 10 litre low level white P.V.C. flushing cistern, including flush pipe, conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required complete all as specified and directed
51M&L for Pedestal pan and trap, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc.. Complete all as specified and directed
52Providing and fixing White Vitreous China Wash basin size 550x400 mm with C.I. brackets anda 15 mm CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever requiredcomplete all as speciifed and directed
53S&F 60cm long PVC connection with two Nos PTMT nut and rubber washers suitable for 15mm bore GI pipe complete all as specified and directed.
54S&F fancy type bib taps 15mm bore for iron pipe fancy type chromium plated butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
55S&F angle stop valves 15mm bore for iron pipe fancy type chromium plated screwed down high pressure with butterfly handle screwed both ends, complete all as specified and directed.
56S&F pillar tap cast copper alloy 15mm bore with capstan heads fancy type chromium platedscrewed down high pressure with butterfly handle screwed both ends complete all as specified and directed.
57S&F 20mm dia gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed.
58S&F CP Soap dish of approved quality and make including fixingapproximate size 160x 160x90mm complete all as specified and directed
59S&F ISI marked PVC (SWR) \"P’ trap 125/100 mm complete all as specified and direcetd
60S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement Complete all as specifed and direcetd
61Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm45gms/40mm-60 gms)?
62waste pipe for WHB. GRATINGS
63M&L for ISI marked Rotational moulded polyethylene water storage tanks (cylindricalvertical with closed top) hoisted and fixed in position all as specified in SSR part-I for capacity 1000 liters incl hoisting and fixing at speciifed location complete all as specified and directed
64M&L for Ballbrass valve,High Pressure,with polythene float and flynut complete,screwed for iron pipe or brass ferrule and fixed complete all as specified and direcetd.
65S&F for ISI marked PVC (SWR) pipes 110mm PVC single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed in wall through clamp complete all as specified and direcetd
66S&F ISI marked PVC BEND (SWR) bends any radius 110mm complete all as specified and direcetd.
67S&F for HEEL REST BEND Bends (any radius) with duck\"s foot or heel rest complete all as specified and direcetd.
68S&F 15mm bore GI tubing medium grade with all fittings to wall and ceiling or laid in floors complete all as specified and directed.
69All as per srl item No.here-in-before but 20mm bore complete all as specified and directed.
70CLAMP IRON
71UPVC Pipes (SCH-40) , 100mm DRAIN WATER PIPE
72UPVC Pipes (SCH-40) , 75mm DRAIN WATER PIPE
73Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified, 50 mm UPVC WATER PIPE (Inlet)
74Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified, 40 mm UPVC WATER PIPE(Outlate)
75Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified, 25 mm UPVC WATER PIPE
76Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified, 16 mm UPVC WATER PIPE
77Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
78M&L for reinforced cement concrete pipe 150 mm dia class NP2 laid and jointed complete with collars as in sewar lines and jointed complete all as specified and directed.
79M&L for cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in bed for drain pipes of bore 150mm including packing under and haunching against the sides of pipes after they are laid in foul condition and testing complete all as specified and directed.
80M&L for brick work with old size burnt clay bricks, sub class B, straight or curved on plan exc 6m mean radium built in cement mortar 1:6 complete all as specified and directed.
81M&L for PCC 1:2:4 type B1using 20mm graded stone aggregate as in coping, benching, bed block for rungs, window cills etc including necessary form works complete all as specified and directed.
82M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cementcomplete all as specified and directed.
83Supply only integrated water proofing compound complete all as specified and directed.
84M&L for precast reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate for cover slab for drainset in cement mortar 1:4 including necessary form work complete all as specified and directed.
85M&L for plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in coping including necessary form work complete all as specified and directed.
86M&L for machine pressed precast concrete interlocking paver block any shape and size with Grey cement andpigment conforming to IS 15658-2006 of 60mm thickness , M-35 Grade complete all as specified and directed.Note:- (i)Thecontractorshallsubmitthetestcertifcateofpaverblockofeachlotheprocuresfrom the approved manufatures.(ii)The department will send sample for testing for compressive strength of eachlotprocured,thequotedrateshallbeinclusiveoftestingcharges.The materialsshallnotbeused at site till the approval of GE after testing is being made to contractor.
87M&L for preparation of newly concrete surface exc 10cm in width or girth and applying two coats of synthetic enemal paint in two colour over a coat of cement primer complete all as specified and directed.
88M&L for framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
89M&L for mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
90M&L for applying two coat of synthetic enamel paint over a coat of red oxide/Zinc Chrome primer including preparation of new steel surfaces complete all as specified and directed.
91Providing and fixing G.I.chain-link fabric fencing Made of G.I. wire of dia 4mm of required width in mesh size 50x50mm including strengthening with MS bars of appropriate size and length or nuts, bolts and washers as required complete all as per specified and directed. Note:- Payment of MS bars shall be done separately
92S&F galvanised 2 strand steel barbed wire fencing with 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to RCC posts (nibs) including securing or tying at crossings with and provisions of galvanised MS wire staples or steel pins,etc as directed (each line wire to be measured).
93M&L for 10mm thick rendering in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
94M&L for preparation of new plastered surfaces of walls and applyingtwo coats ofcement base paint complete all as specified and directed
95M&L for mild steel work conforming to Fe-310-0 or 410-0 as in bands, hold fasts, wall ties, wind ties straps, supports and stay for rain water pipes,clamps and similar articles complete all as specified and directed.
96M&L framed work such as grills, gratings, with ornamental & intricate design etc., with ends of bar shoulder &/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders,framed balusters, walk ways; railings,for portions framed and hung as gates, including pintle hinges, stops,hand-made sliding bolts, etc.& similar work conforming to Fe 290 GDE -E-165 complete all as specified and directed.
97M&L for framed bracket of angles or tees with web & flanges cut to shape, drilled & countersunk for screw, including bending & welding angles, as necessary, gusset plates, riveting, etc., n exc 10kg each brackets, conforming to Fe 290 GDE -E-165 complete all as specified and directed.
98E/M Work
99M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated and unsheathed single core FRLSH copper cable 1100 volts grade with multistranded copper conductor in and including cutting of chases to lay PVC rigid concealed conduit (medium grade), exposed to surface wherever required including conduit as specified, and making good to surface by using cement mortar 1:3, and using of wall finish paint to match the existing surface as specified including all fittings and conduit accessories also,complete including PVC insulated and unsheathed FRLSH single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth dolly for one light/fan point controlled by one, one way switch complete all as specified and directed.
100M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated and unsheathed single core FRLSH copper cable 1100 volts grade with multistranded copper conductor in and including cutting of chases to lay PVC rigid concealed conduit (medium grade), exposed to surface wherever required including conduit as specified, and making good to surface by using cement mortar 1:3, and using of wall finish paint to match the existing surface, as specified including all fittings and conduit accessories also, including PVC insulated and unsheathed FRLSH single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth dolly for one socket outlet 5 Amps on independent board controlled by one, one way switch complete all as specified and directed.
101M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated and unsheathed single core FRLSH copper cable 1100 volts grade with multistranded copper conductor in and including cutting of chases to lay PVC rigid concealed conduit (medium grade), exposed to surface wherever required including conduit as specified, and making good to surface by using cement mortar 1:3, and using of wall finish paint to match the existing surface, as specified including all fittings and conduit accessories also, in the same board as other swiutches complete including PVC insulated and unsheathed FRLSH single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth dolly for one socket outlet 5 Amps on same board controlled by one, one way switch complete all as specified and directed.
102M&L for point wiring with 4.0 Sqmm(nominal area) PVC insulated and unsheathed single core FRLSH copper cable 1100 volts grade with multistranded copper conductor in and including cutting of chases to lay PVC rigid concealed conduit (medium grade),exposed to surface wherever required including conduit as specified, and making good to surface by using cement mortar 1:3, and using of wall finish paint to match the existing surface, as specified including all fittings and conduit accessories also, including PVC insulated and unsheathed FRLSH single core multistranded copper conductor cable of size2.5 Sqmm green in colour as earth continuity conductor connected to common earth dolly for one socket outlet 6 pin 15/16 Amps on independent board controlled by one, one way switch complete all as specified and directed
103S&F DB, double door,SPN, 415 Volts 08 wayscompleteall as specified and directed .Make:- Legrand/ Havells/ L&T/Indoasian
104S&F call bell AC 240V single pole completeall as specified and directed .Make-Havells/Bajaj/CG
105S&F exhaust fans AC single phase 230/240 V of size 450 mm sweep with louver completeall as specified and directed. Make-Bajaj/Halonix/Havells/CG
106S&F fans ceiling complete with electronic type regulator and accessories 230V, 1200 mm sweep, BEE 5 star rated completeall as specified and directed. Make-Bajaj/Halonix/Havells
107S&F LED securutylight fittings 35 Watt 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete all as specified and directed.
108M&L for modular switch 1 way, 6A, 1 module completeall as specified and directed.
109M&L for modular switch 1 way, 16A, 1 module completeall as specified and directed.
110M&L for socket, modular, 6A-2/3 pin combined, 2 module completeall as specified and directed.
111M&L for socket, modular, 6A/16A -2/3 pin combined, 2 module completeall as specified and directed.
112M&L for ceiling rose 63.5x23.5 mm 3 terminals, PVC/Polycarbonate, isolated body completeall as specified and directed .
113M&L modular white cover plate with frame 8 modulecompleteall as specified and directed .
114M&L modular white cover plate with frame 2 module completeall as specified and directed .
115M&L modular metal flush box 2 module completeall as specified and directed .
116M&L modular metal flush box 8 module completeall as specified and directed .
117S&F MCCB 100 Amps, 3P, 16KA completeall as specified and directed . Make:- Legrand/ Havells/ L&T/Indoasian
118S&F DBSPN 8 WAY double door completeall as specified and directed .Make:- Legrand/ Havells/ L&T/Indoasian
119S&F MCB, SPN, breaking capacity min 10KA,\"C\" curve230V,63 Amps completeall as specified and directed .Make:- Legrand/ Havells/ L&T/Indoasian
120S&F switch flame proof rotary type with termination box in LM6,6A/16A single pole 250V completeall as specified and directed .Make:- Legrand/ Havells/ L&T/Indoasian
121S&F switch flame proof switch socket and plug combination in LM6 cable termination box in LM6 ,6A/16A 250 V ,2P +earth completeall as specified and directed .Make:- Legrand/ Havells/ L&T/Indoasian
122M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated and unsheathed single corewith multistranded copper conductor in and including cutting of chases to lay stove enameled steel conduit conduit (medium grade), exposed to surface wherever required including conduit as specified, and making good to surface by usingcement mortar 1:3, and using of wall finish paint to match the existing surface, as specified including all fittings and conduit accessories also,completesingle core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth dolly for one light/fan point controlled by one, one way switch complete all as specified and directed.
123M&L for point wiring with 2.5 Sqmm (nominal area) PVC insulated and unsheathed single corewith multistranded copper conductor in and including cutting of chases to lay stove enameled steel conduit conduit (medium grade), exposed to surface wherever required including conduit as specified, and making good to surface by using cement mortar 1:3, and using of wall finish paint to match the existing surface, as specified including all fittings and conduit accessories also,completesingle core multistranded copper conductor cable of size 2.5 Sqmm green in colour as earth continuity conductor connected to common earth dolly for one light/fan point controlled by one, one way switch complete all as specified and directed.
124M&L for 19475Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length,buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion complete all as specified and directed.
125S&F rigid non metallic PVC conduit 20mm dia exclusive of boxes (junction/terminal) but inclusive of all tees,bends,elbows,reducers,bell mouth tube ends and fixing accessories such as couplers,lock nuts,saddles,pipe hooks of dia-20mm complete all as specified and directed.
126M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat complete all as specified anddirected.
127Supply & laying LTXLPE insulatedunder ground 1100 volt grade with stranded aluminium conductor of following sizes25 Sqmm 4 core in trenches /passing through pipes/ on poles etc complele all as specified and directed.
128M&L for 33- layer PP-R Polypropylene random copo lymer) conceal ed pipes SDR 7.4 (PN16) UV stabi lized and antimi crobial fusion welded having thermal stability for hot & cold water supplyall PP-R plain & brass threaded polypropylene random fittings laid in trenches in replacement for UPVC pipes complete all as specified and directed for the following size.
12932mm outer dia
13063mm outer dia
131S&F PPR gate valves (Brass inlet ) for outer dia of pipe 32mm complete all as specified and directed
132S&F in repairs SFRC precast cement concrete perforated drain cover with frame of size 900mm x 450mm x 70mm thick surrounded with steel strip 70x2mm reinforced as per manufacturer\"s design in Manufactured proccess laid over existing drain complete all as specified and directed.Notes: - (i) Make of SFRC Manhole/drain cover and frame :(a) M/s PS Concrete.(b) M/s KK Manhole.Or equivalent as approved by GE. (ii) Contractor shall provide purchage vouchers along with manufacturer test certificate of SFRC cover.
133M&L for LLDPE Septic Tanksuitable for mim 30 Users (Office purpose) including necessary earthwork in any type of soil with 250mm thickPCC 1:4:8 type B2 using 40mm graded stone aggregate as in foundation including provn of vent etc.as per manufacture instructions complete all as specified and directed.Make:- (a)Sintex (b)Diplast (c) JS Polyplast (d) Rotex (e)Polycon (f)Finolex
134M&L for soakage wells of 1.20m dia & 3.00m depth including necessary earthwork in any type of soil, foundation in PCC 150mm thickPCC 1:3:6 type B2 using 40mm graded stone aggregate, walls of honey combed masonry with top ring of M25 concrete (X- size 250 x250mm)(with TMT bars of3x 12 mm bottom, 2x 12 mm upper & 8mm striuups @ 100 C/C) including intercepting chamber and screen chamber made of brick masonary in cementmortar (1:6),150 mm thick RCC cover slab in M25 with two layer of 12mm @ 100mm C/C TMT bars in both directions, interconnecting pipes of PVC SWR of length one mtr each complete filled with brick bats complete all as specified and directed.
135Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia with existing angle iron \"Y\" shapedincludingsecuring or tying at crossings with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge
136M&L for concealed Sub main wiring alongwith earth wire,concealed in walls/ floors or fixed in wall/ceiling, including the cutting of chases, including provision of PVC conduit (medium grade) of required size and making good to surface to match the original surface with the following sizes of FRLSHPVC insulated unsheathed copper conductor, single core cable complete all as specified and as directed.
1374 x 6.0 Sqmm + 2 x 6.0 Sqmm earth wire.
1384 x 4.0 Sqmm + 2 x 4 Sqmm earth wire.
1392 x 4.0 Sqmm + 1 x 4 Sqmm earth wire.
140S&F flame proof heavy dutyexhaust fans AC single phase 230/240 V of size 450 mm sweep with louver and 1400 RPM complete and making surface good & finishedall as specified and directed .Make Havells-Turbo force single pole/ Bajaj/Halonix
141M&L flame proof LED ,CMRI certifiedIP 65 complete with suitable lamp, 18/20 Watt and all accessories internally pre-wired andincluding conneting up with three core twisted flexible copper conductor cable of suitable size and making surface good & finished completeall as specified and directed .Make: CromptonCAT No: EXTN1LT 6-18/20or equivalent of Bajaj/Philips/CG)
142M&L for energy LED corrossion resistant batten with polycarbonate housing and opal diffuser IP 65 complete with suitable lamp, 40 Watt and all accessories internally pre-wired andincluding conneting up with three core twisted flexible copper conductor cable of suitable size and making surface good & finished completeall as specified and directed .Make: Halonix CAT No: HLB-04-40-CW or equivalent of Bajaj/Philips/CG)
143M&L for LED 5/5.5 W LED Lampcompleteall as specified and directed .Make-Havells-HSN code-8539/Bajaj/CG
144S&Ftelephone socketcommunication system complete all as specified and directed.
145S&F MCB, SP, breaking capacity min 10KA,\"C\" curve230V, 6 to 32 Amps complete all as specified and directed.
146S&F emergency alarm bell set consisting of transmitting the singnal from one end and receiving on other end of bell completeall as specified and directed .
147S&F flame proof ceiling fans, ISI Marked complete with electronic type regulator and accessories 230V, 1200 mm sweep, BEE 5 star rated completeall as specified and directed .
148M&L for APP (atactic paint proplene) modified pre fabricated fine layer 3 mm thick and weighing not less then 3. 00 Kg/Sqm water proofing membrane reinforced with non- wooven polyster mat black finished over compatible primer @0.4 ltr per sqm of density at 25 degree centigrade 0.87-0.89 Kg per ltr and viscosity 70-160 LPS cold stiched and torch application of mem brane with 75mm side lap & 100mm over lap as required after necessary preparation of the surfaces complete all as per manufactures instruction, ,as specified and directed.
149M&L health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
150600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers
151S&Fin repair 25mm dia MS powder coated tublar curtain rod , including brackets fancy type for each curtain rod complete all as specified and directed.
152S&F CP towel rail 600 mm long fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified and directed.
153S&F CP overhead rain shower rose 125mm size with 450mm long CP overhead shower arm with wall flange complete all as specified and directed.
154M&L for 75 mm thick, PCC (1:3:6) type C-1 using 20 mm graded stone aggregates as in path , plinth protection and paving laid in panels finished even and smooth without using extra cement complete all as specified and directed.
155Schedule of Credit

AI Tender Summary

OUR REF NO 32950738
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 81.16 Lakhs
LAST DATE 02-08-2022
Authority
Authority Name Military Engineer Services
Work Description Provision Of Armoury At Air Force Station Palam Under Ge ( P ) Af Gurgaon
Basic Detail
Tender No CWE/TKD/GUR/79/2021-22
Bidding Type Tender
Location
City palam
State Haryana
Key Dates
Publish Date 26 Jul 2022
Submission Date 02 Aug 2022
Open Date 04 Aug 2022
Finance
Tender Value 81.16 Lakhs
Tender Fee 1000
EMD 1.46 Lakhs
Exemption Not Available
Document List
Tender.pdf
Tendernotice_1.pdf
5e5366a5-d66b-4d31-a54d-cdd4777613bc.html
AppxPS.pdf
BOQ_598807.xls
Drawings.rar
PS.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 26, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 26, 2022
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 26, 2022
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 26, 2022
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 26, 2022
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 26, 2022
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 02, 2022
18:00 IST

Corrigendum-6 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 02, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 04, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tender.pdf

pdf

Tendernotice_1.pdf

html

5e5366a5-d66b-4d31-a54d-cdd4777613bc.html

pdf

AppxPS.pdf

xls

BOQ_598807.xls

rar

Drawings.rar

pdf

PS.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders