Repair / Maintenance To Crane, Firefighting Pipe Lines, Lt Oh Lines / Ug Cables, Lt Feeder Piller, Dg Set Panels, Connected Switch Gear, Renewal To Split / Window Ac, Geysers, Desert Coolers At Otg & Bhadoriya Complex And Attending Day To Day C, pathankot-Punjab

Military Engineer Services-MES has published Repair / Maintenance To Crane, Firefighting Pipe Lines, Lt Oh Lines / Ug Cables, Lt Feeder Piller, Dg Set Panels, Connected Switch Gear, Renewal To Split / Window Ac, Geysers, Desert Coolers At Otg & Bhadoriya Complex And Attending Day To Day C. Submission Date for this Tender is 02-08-2022. Switch Gear Tenders in pathankot Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

32947210
Corrigendum : Repair / Maintenance To Crane, Firefighting Pipe Lines, Lt Oh Lines / Ug Cables, Lt Feeder Piller, Dg Set Panels, Connected Switch Gear, Renewal To Split / Window Ac, Geysers, Desert Coolers At Otg & Bhadoriya Complex And Attending Day To Day C
Open Tender
Indian
Punjab
pathankot
02-08-2022

Tender Details

Repair / Maintenance To Crane, Firefighting Pipe Lines, Lt Oh Lines / Ug Cables, Lt Feeder Piller, Dg Set Panels, Connected Switch Gear, Renewal To Split / Window Ac, Geysers, Desert Coolers At Otg & Bhadoriya Complex And Attending Day To Day Complaints Of Summer Appliance Maint Of Stp & Other Misc E / M Installations At Dhangu Military Complex Under Ge South Pathankot

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Jul-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-08-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 78000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/ MAINT TO CRANE, FIREFIGHTING PIPE LINES, LT OH LINES/UG CABLES, LT FEEDER PILLER, DG SET PANELS, CONNECTED SWITCH GEAR, RENEWAL TO SPLIT/ WINDOW AC, GEYSERS, DESERT COOLERS AT OTG & BHADORIYA COMPLEX AND ATTENDING DAY TO DAY COMPLAINTS OF SUMMER APPLIANCE MAINT OF STP & OTHER MISC E/M INSTALLATIONS AT DHANGU MILITARY COMPLEX UNDER GE SOUTH PATHANKOT.
Sl. No. Item Description
1M & L for maintenance /repairs or periodical checkwith skilled crane repair to all component of EOT crane 2 Ton capacityincluding limit switches vertical and horizontal motion and longitudial motion and load testing, greasing/ lubricationto all movable parts, rail track line of crane, adjustment/ rectification of flexible cable with cable carrier/ replacement of PVC cable carriers, rectification/ tightening of all electrical connections at main EOT panels and connected electrical drive motors, checking and rectification of brake system with replacement of tie rod , replacement of gear oil/ replacements of gasket/oil seal and required nut and bolts checking/rectificationof portable/ pendent control panel and checking/rectification of cranes light pointsfor smooth functioning and cleaning and dusting of all components for 3 time in each month complete all as specified and directed. Note-(i)All spares parts/ item/stores reuired for replacement shall be measuredand saperately as respective sch "A" ser items. (ii) Srl item No 1in abovelabour onlycharges has been considered.
2All as per Srl item No 1 above but for 5 Ton capacity crane
3All as per Srl item No 1 above but for 15 Ton capacity crane
4Supply and Fixing in Replacement of Lever Type Limit Switch 2 Way Type LS /2SH2 in IP54 enclosure with two Contacts for 2 ton to 15 Ton crane complete all as specified anddirected.
5Supply and Fixing in Replacement of Rotary Type Limit Switch Gear Ratio 48:1 with 2 N.O.+2 N.C. Contact in IP54 Enclosure all is Directed .
6Supply and fixing in replacement of electromagnetic break 200 mm 415 V AC supply for hoist motion complete all as specified and directed .
7Supply and Fixing in Replacement of Electro hydraulic thruster operated brake suitable for hoisting motion/cross travel motion for crane 2 to 15 Ton crane, 415V, AC supply complete all as Directed .
8Supply and Fixing in Replacement of Electro hydraulic thruster operated brake suitable for long travel motion for crane 2 to 15 Ton crane, 415V, AC supply complete all as Directed .
9Supply and fixing in Replacement of Electro Hydraulic Thruster Break shoe 250 mm and 18 Kg for Hoist Motion/cross travel motion all as Directed.
10Supply and fixing in Replacement of Electro Hydraulic Thruster Break shoe 250 mm & 18 Kgfor long travel motion all as Directed .
11M&L for repairing of Helical Gear Box for Hoist Motion Horizontal Type opening and removing Hoist Gear Box Top Cover by unscrewing Nut Bolts , side shaft plates etc & replacement of damage oil Seal , gaskets of suitable size and replacement of gear oil after washing flushing & cleaning gear Box Chamber completely by kerosene oil,and refixing the same as directed. Note : ( Gear oill will be measured & Paid separately)
12M&L for repairing of Helical Gear Box of L.T. & C.T. Motion Vertical Type for 2 ton to 15 ton crane and opening and removing of LT & CT Box Top Cover by unscrewing Nut Bolts , side shaft plates etc. Replacement of Damage Oil Seal , Gaskets of Suitable size and replacement of Gear Oil after washing flushing & cleaning Gear Box chamber completely by kerosene Oil and refixing the same as directed. Note :( Gear oil will be measured & paid separately).
13Supply and Fixing in replacement of Heavy duty Resistance Box Naturally Air Cooled Punch steel Grid type suitable for 15 HP Slip Ring Motor RV-260,RA-27.7 4 step 10 Minutes Rating Balance type in M.S.Sheet Enclosure ( Zinc Plated) in well ventilated Housing Make- Lachhman Electronics
14Supply and Fixing in replacement of Heavy duty Resistance Box Naturally Air Cooled Punch steel Grid type suitable for 3 H.P. SlipRing Motor RV-90,RA-12 3 step 10 Minutes Rating Balance in M.S Sheet Enclosure ( Zinc Plated) in well ventilated Housing Make : Lachman Electronics
15Supply of Gear Oil complete all as specified and directed.
16Supply and fixing of stainer wire 6 mm with end bracket 2 Nos for E.O.T Crane End Carriage side welded including cutting welding complete all as specified anddirected .
17M & L for power contactor 3 pole 23 Amp, 110volt complete all as specified and directed. Make BCH/Legrand.
18M&Lfor overload relay 1.0 to 1.4 Amp complete all as specified and directed.
19Dismantling/strip opening micro drive box complete with rectifier transformer arrangement, megnatic disc both side coupling for remotting both side ends of driving shaft (gear box coupling side and braking arrangement coupling side) making multi key arrangement on both the shaft and coupling (Teeth system) to avoid any kind of play in coupling and shaft including replacement of 04 Nos carbon bushes, replacement of o2 Nos gun metal bushes including making oiling arrangement in bushes and side covers of bushes/housing of micro drive reassembling/testing complete (crane capacity 2 to 15 Ton) all as specified and directed .
20M &L for servicing of Push Button Station 8 way and replacement of unserviciable Push Button with Element.
21Dismantling carefully motor electric squirrel cage inductyion type and carrying out rewinding with super enamelled copper windings wire of suitable size so as to provide rated output at rated speed complete including all other winding materials such as leathroid paper,bamboo strips,PVC insulation tape,cotton tape, PVC sleeves,insulation varnish etc complete including assembling testing and comprising of motors of 3 phase 400-440 Volts, 50 cycles/second, 1440 RPM of 5 HPto 15 HP capacities complete all as specified and re-fixing. Note :- (Quotedrate shall deemedto be included for disconnecting and refixing in position)
22M&L for break /compresure oil for EOT crane up to 15 Ton capacity complete all as specified and directed.Make Survo/HP
23M& L for grease for EOT crane up to 15 Ton capacity complete all as specified and directed .Make Survo/HP
24M & L for replacement of flexible coupling suitable perfact allignment beetween motor and driven machine with greasing and replacement of suitable nuts and bolt complete all as specified and directed.
25M & L for replacement of tie rod of break system and nut, bolt complete all specified and directed.
26S&F in replacement of hoist rope ,which is well suited for high cycle applications like overhead cranes,High breaking load and resistance to bending fatigue and suitable for 2 to 15 ton load carring capacity.
27M&L for repairing of wheel for LT and CTof 2 to 15 ton crane and removing bearing Cover by unscrewing Nut Bolts , side shaft plates etc & replacement of gaskets of suitable size and greasing of bearing after washing flushing & cleaning bearing and casing Chamber completely by kerosene oil,and refixing the same as directed. Note : ( greasing will be measured & Paid separately)
28Taking down existing unserviceable Lightning arresetor and S&F HT lightening arrestor metal oxide type (gap less) heavy duty single pole for 11 KV overhead line, suitable for 12 KV rated highest system voltage, long duration distribution discharge class type,IP 55 Degree of protection, 100(kVp) at 65 kAHigh current impulse withstand voltageand 9 KV Arrestor ratingwith normal discharge current of 10 KA complete with all fittings conforming to IS: 3070 part-3effectively connected with earthing system complete all as specified and directed by Engr-in-Charge. Note:- Manufacturer"s Test certificate for lighting arrestor shall be produced before claiming for payment.
29Dismantling air break gang operated switches triple pole vertical/ horizontal mounted including isulators and opretaing mechanism forreplacment all as directed.
30Supply , install, testing and commissioning of HT 11 KV Switch air break, gang operated, triple pole , mechanically operated, mounted on insulators and MS channel frame, with operating mechanism made out of 25 mm dia GI medium grade pipesuitable for operation from ground level with locking arrangement complete for current rating 200 Amps complete all as specified and directed by Engr-in-charge.
31Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr deep hard /dense type of soil getting out and levelling of bottom surface to required level for poles/stay assebly/cable all as specifed and directed.
32Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25m thick all as specified and directed.
33Removing excavated material from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point all as directed.
34M&L for Sub class ‘B’ bricks old size laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required.
35Supplying & Laying in trenches clear sand for cushioningunder ground cable 8 cm below and 15 cm above complete in level all as specified.
36Laying only old bricks retrieved from item No.31 of any size/type laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
37Removingexisting 1100 volts grade,XLPE/PVC, armoured, electric power cables (heavy duty) with aluminium conductorof sizes6 Sqmm 4 core to 70 Sqmm 3.5 core from trench/ duct/ pipe carefully for identifying the defects and relaying the same after rectification of defects complete all as directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
38Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium counductor, 1100 volts grade of crosssectional area 16 Sq mm 2 core.Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
39Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium counductor, 1100 volts grade of crosssectional area 16 Sq mm 4 core.Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
40All as per item No39 above but of size 10 Sq mm 2 Core
41All as per item No39 above but of size 25 Sq mm 3.5 Core
42All as per item No39 above but of size 25 Sq mm 4 Core
43All as per item No39 above but of size 35 Sq mm 3.5 Core
44All as per item No39 above but of size 50 Sq mm 3.5 Core
45All as per item No39 above but of size 70 Sq mm 3.5 Core
46Supplying and fixingin replacement of old u/sservice cable size 10 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service with galvanised steel wirecomplete all as spd and directed.
47LT PANEL :Supply, install, commisoning and Lt distribution control panel board, outdoor type, mounted on rigid angle iron frame,having independent compartment for bus bar, incoming feeder and each out going feeder, dust and vermin proof, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with copper bus barof 400 Amps rating for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supproted on epoxy insulators - 01 Set, common earth basbar of GI stip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottomm for each out going and in coming cables and coplete panel board painted with powder coating in siemens grey colour and fabricated with double door system lockable arrangements along with brick work and cattel fencing all as spproved and comprising as under :-i) Aluminium Bus bar 400 A- mounted on porcelain insulator - 01 Set ( Set of 4 Nos)with PVC sleeve insulation ii) MCCB 4 pole 415 V 3 phase 200 Amp, 36KA (Thermal magnetic release) Ics=100%Icu- 01 Nos (Incomming) iii) MCCB 4 pole 415 V 3 phase 100 Amp, 25 KA (Thermal magnetic release) Ics=100%Icu- 02 Nos (outgoing) iiv) MCCB 4 pole 415 V 3 phase 63 Amp, 25 KA (Thermal magnetic release) Ics=100%Icu- 02 Nos (outgoing) v) Digital Voltmeter of size 96x96mm 0-500 volts with selector switch - 01 Nos vi) Digital Amp meter of size 96x96mm rating 0-100 Amp with CT"s & slection switch - 01 Nos vii) RYB LED indicator- one set (viii) Brick work for plinth -01 Job
48LT PANEL :Supply, install, commisoning and Lt distribution control panel board, outdoor type, mounted on rigid angle iron frame,having independent compartment for bus bar, incoming feeder and each out going feeder, dust and vermin proof, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with copper bus barof 400 Amps rating for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supproted on epoxy insulators - 01 Set, common earth basbar of GI stip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottomm for each out going and in coming cables and coplete panel board painted with powder coating in siemens grey colour and fabricated with double door system lockable arrangements along with brick work and cattel fencing all as spproved and comprising as under i) Aluminium Bus bar 400 A- mounted on porcelain insulator - 01 Set ( Set of 4 Nos)with PVC sleeve insulation ii) MCCB 4 pole 415 V 3 phase 250 Amp, 36KA (Thermal magnetic release) Ics=100%Icu- 01 Nos (Incomming) iii) MCCB 4 pole 415 V 3 phase 200 Amp, 36KA (Thermal magnetic release) Ics=100%Icu- 01 Nos (Outgoing) iv) MCCB 4 pole 415 V 3 phase 160 Amp, 25 KA (Thermal magnetic release) Ics=100%Icu- 03Nos (outgoing) iv) MCCB 4 pole 415 V 3 phase 100 Amp, 25 KA (Thermal magnetic release) Ics=100%Icu- 03Nos (outgoing) vi) Digital Voltmeter of size 96x96mm 0-500 volts with selector switch - 01 Nos vii) Digital Amp meter of size 96x96mm rating 0-100 Amp with CT"s & slection switch - 01 Nos viii) RYB LED indicator- one set (ix) Brick work for platform along with cattle fencing-01 Job
49Supply, installing, testing and commissioning of LT feeder pillar box factory madecubicle indoor type, fabricated out of 2.00 mm thick CRCA sheet with angle iron base frame made of 40 x 40 x 6mm , 45 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire weather proof, with IP-66 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs groutedin PCC complete including paintingwith two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminium busbar (TPN), suitable double compression copper cable glands complete in all respect for Bay work station and includingprovn of the following:-Note: The panel shall be as per CPRI certificate. Note : PCC deemed to be inclusive of the rate quoted abovei)Aluminium Bus bar 400 A- mounted on porcelain insulator - 01 Set ( Set of 4 Nos)with PVC sleeve insulation ii) MCCB 4 pole 415 V 3 phase 250 Amp, 36 KA (Thermal magnetic release) Ics=100%Icu- 01 Nos (incoming) ii) MCCB 3 pole 415 V 3 phase 160 Amp, 25 KA (Thermal magnetic release) Ics=100%Icu- 02 Nos (outgoing) ii) MCCB 3 pole 415 V 3 phase 100 Amp, 25 KA (Thermal magnetic release) Ics=100%Icu- 02 Nos (outgoing) vi) Digital Voltmeter of size 96x96mm 0-500 volts with selector switch - 01 Nosvii) Digital Amp meter of size 96x96mm rating 0-100 Amp with CT"s & slection switch - 01 Nos viii) RYB LED indicator- one set
50Taking down old burnt out MCCB (of any size, make ,shape ) and supply and fixing new MCCB with the existing cable after making it good by cutting out the burnt parts of the cable/lugs, crimping new lugs as per the suitable size, connecting with the new MCCB along with spraders, testing complete all as directed and specified
51(i) MCCB 04 pole of 250 current rating with rapturing capcity of 35 KA, 415V, 50Hz, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% complete all as specified
52(ii)MCCB 04 pole of 160 A current rating with rapturing capcity of 25 KA, 415V, 50Hz, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%,complete all as specified
53(iii) MCCB 04 pole of 125 A current rating with rapturing capcity of 25KA, 415V, 50Hz, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% complete all as specified
54(iv) MCCB 04 pole of 100 A current rating with rapturing capcity of 25KA, 415V, 50Hz, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% complete all as specified
55(v) MCCB 04 pole of 200 A current rating with rapturing capcity of 25 KA, 415V, 50Hz,(Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%, complete all as specified
56(v) MCCB 04 pole of 63 A current rating with rapturing capcity of 16 KA, 415V, 50Hz ,(Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%, complete all as specified
57Disconnecting and removing existing unserviceable battery depositing to MES store yard and S&F maintenance free battery 12V 180 AH including terminal clamps, copper lead 3mlong eachincluding testing and commissioning all as directed by Engineer-in-Charge.
58Supply only LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling all as completed and directed.
59Dismentling old feeder pillar &Supply, installing, testing and commissioning of LT feeder pillar box factory madecubicle outdoor type, fabricated out of 3.00 mm thick CRCA sheetfloor mounted with angle iron base frame made of 40 x 40 x 6mm , 50 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire ,Square copper bus bar Chamber 320 Amp Capacity weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs groutedin PCC complete including paintingwith two coats of epoxy powder paint over a coat of primer complete including supply fixing and making provision of the following :- (a) MCCB 4 pole 415 volts 3 phase 200 Amp 25 KA -01 No (f) LED Indicator RYB -01 Set ( Set of three). Note: The panel shall be as per CPRI certificate. Note : PCC will be measured and paid separately.
60Supply & fixing CI fittings up to 150 mm bore such as ( any type, bend/color/reducer and angle) tapers any type ( straight, bendsincreasing,decreasing or double socket etc ) tail pieces single branch Y junction,double branch cross ( all sockets or socket ends spigot). All as required at work site and as directed.
61M & L forS&F of CI sluice valve flanged of size 150 mmbore class PN-1.0 ISI marked with stainless steel spindle and iron wheel head complete with rubber gaskets, nuts, bolts washers and packing materials etc all as directed and as per site requirement.
62All as per Srl No 61 above butof size 100MM
63All as per Srl No 61 above butof size 80 MM
64Supply and fixing of CI non return valve of size 150 mm bore flanged ISI marked including bolts, nuts, washers and rubber gasket etc complete all as directed.
65M & L for supply and fixingGun metal gate valve ISI marked with iron wheelhead screwed both ends for pipe of size 50 mm .
66All as per Srl No 65 above butof size 25 MM
67All as per Srl No 65 above butof size 15 MM
68M & L for attending break down of pipe ling bursting /cracks including excavation in hard/dense soil with the use of earthmoving machinery/labour and taking out old CI/GI/MS defective/misaligned water pipe ling of size 200/150/100/50 mm dia bore carefully after disconnection of Joints to a length up to 6 mtr and create bund with excavate earths and excavated earth and dewatering/bailing out water complete with diesel engine driven pump set and positioning the pipe line after repairs/porocline all as directed by Engineer-in-Charge. Note:- (a) M/L for lead joints/spares/CI/GI specials will be measured and paid separately.(b) M/L for CI/GI/MS pipe, special lead joints ect will be measured and paid separately under relevant schedule items. (c) The rate is deemed to include cost for tool and plant and transportation required for attending the repair work. (d) Disconnecting /dismantling/cutting the existing pipe line is included in quoted rate. (e) The rate is inclusive of earth work complete including returinging and refilling in any type of strata complete. (f) The break down shal be attended within 4 hrs of intimation round the clock and time of restoration shall be maximum of 5 hrs. The additional manpower required to complete the work is quoted rate is deemed to be included in the quoted.
69Cutting existing CI/MS water main 150 mm bore pipe and firefighting pipeline in position for making branch connection and CI pipeline(Insertionof CI tees bends of different size on connection pieces or for insertion of sluice valve) including excavation& earth work.Note : Cast iron fittings such as tees, bends, collars reducers etc)joints and jointing material for fixing cast iron fittings, sluice valve shall be measured and paid separately.
70All as per Srl No 69 above butof size 100 mm
71M&L joints with rubber gaskets for CI flanged pipe including necessary nut bolts and washers etc for pipe 150 mm bore all as specified.
72S&F replacement brass spindle with checknut suitable for sluice valve of size 80 mm bore including replacment of gland packing all as directed make : BIR/VENUS/MINAR
73All as per description of srl item 72 above but of size 100 mm bore.
74All as per description of srl item 72 above but of size 150 mm bore.
75S&F rubber mat 1x 2 mtr 19 mm thick laid down in front of LT panel / bus bar complete ISI marked.
76Supply and fixing battery heavy duty 12 volt 180 Ah heavy duty with battery leads.
77Supply only searchlight reachargeable heavy duty.
78Supply and fixing pvc insulated copper conductor multistandardcable of size 25 sqmm single core.
79M&L for fire point comprising of the following. (a) CO2 fire extinguisher 4.5 Kg (02 Nos), b) Dry carbon powder (ABC)-05 Kg (02 Nos), ceiling Hook,fire beater,sand buckets 9 mtrs capacity-02 Nos, Showel complete with angle iron stand duly painted with two coats of synthetic enamel paint of approval colour over a coat of red oxide primer incl dismentling old unsv one.
80M/L for carrying out physical, chemical & Bacteriological analysis all as per IS 10500:2012 for Drinking water sample of the Fresh water Pump Houses at various locations from approved laboratory .Note : The rate quoted deemed to inclusive of collecting water sample in Sterilised bottle/PVC container & submitting the same for testing.
81Taking down carefully point wiring of any type, size and description from hard/ teak wood batten/through pipes/casing capping(light, fan, sockets and socket outlets etc) including removal of battens, pipes, plug sockets, socket outlets, switches, shades, ceiling roses, light fittings etc. complete and making good the disturbed surface to match with existing all as directed by Engr-in-Charge.
82Taking down main switches, distribution boards and cut outs etc. of any type and capacity along with the existing boards and removing the same from site and making good the disturbed surface/portion of walls all as directed by Engr-in-Charge.
83Taking down carefully sub main wiring of any nos of wire and size with earth wire from wooden batten/surface conduit/casing caping complete with its all accessories
84M & L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FR type multi stranded copper conductor, single core drawn in and including not less than 20 mm dia steel conduit "medium grade" including all steel conduit accessories on surface wiringincluding concealed pressed steel terminal box of required size factory made duly painted inside & outside with two coats with top cover of ISI Marked plastic laminated sheet of required colour for mounting switch, sockets, fan regulator etc including 1.5 Sqmm FR type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site& including chases cutting& making good disturbed surface & applying finishes to match existing surface etc. all as specified for thefollowing.
85All as per Item No. 84 above but for one light/fanpoint controlled by one, one way switch single pole.
86All as per Item No. 84 above but One Flame proof switch socket and plug combination in LM6 cable termination box in LM LM6, 16 Amp independent with cables 4 Sq mm
87S & F in repair Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed.
88S & F in repair LED tube, T8, 20W, Ultra bright LED polycarbonate tube light with very high efficiency suited for installation in existing flame proof fitting with G13 lamp holder complete all as specifiedand directed.
89Supply and fixing in repair LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as directed and specifed.
90Supply and draw sub main wiring in repairs of two run 4.0 sqmm single core PVC insulated, unsheathed multistranded copper conductor cable 1100 Volt grade, drawn through and including PVC conduitmedium duty and accessories of not less than 25 mm size ISI marked including all conduit accessories for concealed to the surfaces of the wall/ceiling including one run of4.0 sqmm single core PVC insulated unsheathed copper earth continuity conductor all as specified and as directed.(NOTE : Two runs of single core cable with one run of earth continuity conductor including PVC conduit accessories shall be measured and paid as one length.) including making good disturbed surface all as specified and directed.
91Supply and draw sub main wiring in repairs of two run 6.0 sqmm single core PVC insulated, unsheathed multistranded copper conductor cable 1100 Volt grade, drawn through and including PVC conduitmedium duty and accessories of not less than 25 mm size ISI marked including all conduit accessories for concealed to the surfaces of the wall/ceiling including one run of6.0sqmm single core PVC insulated unsheathed copper earth continuity conductor all as specified and as directed.(NOTE : Two runs of single core cable with one run of earth continuity conductor including PVC conduit accessories shall be measured and paid as one length.) including making good disturbed surface all as specified and directed.
92S & F in repair Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed by Engr - in- charge
93S&F Flame proof distribution board enclosure 8 way made out of galvanised steel sheet class EX II housed with flame proof MCBs of following capacities :- (a)MCB SPN 10 KA breakng capacity 32 Amps - 01 No (b)MCB SP 10 KA breaking capacity 6 Amps-06 Nos
94Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly inground (Earth pit not less than 2.25 Mtr deep below normal ground level )with topedge of the plate not less than 1.5 Mtr belownormal ground level connecting with galvanizediron GI earth wire 4mm dia by means ofbolt nut check nuts and washersof galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified orindicatedincludingtesting on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting totest point etc. all as required at site for complete earthing).
95M&L for replacement of existing unsv earthing with steelearth plate electrode ofsize 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate,removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and directed.
96Supply and fix off loadchange over switch 415V in sheet metal enclosures 4 pole of capacity 630 Amps.
97All as per item No 96 above but of size 400 Amps
98Material & Labour taking out the defective unserviceable hermetically sealed compressor from the walking cooler unit, replacing the compressor with new compressor of the same capacity, fixing to the unit inter connecting the refrigerating lines, flushing out the cooling coil & condenser, removal the coil & carbon thoroughly, cleaning with CTC, leak testing, pressure testing with Nitrogen gas, dehyderating, Vaccumissing, charging of Refrigerant gas, testing at work shop. Shifting to the location reinstalling the same in its Original position connecting up all etestion electrical, connection and Testing & Commissioning. All as specified as directed. Note : Rate quoted is deemed to be inclusive of cutting, welding, brazing, sealing the refrigerant tubing, replacement of strainer, CTC, Nitrogen gas, Refrigerant gas, required to and from Transportion and Handling. M/L for spares will be measured and paid separately
99Material and Labour for complete repair to out door unit of walking in cooler including taking down all the components tinkering the rusted portion, renewal of complete rusted sheet metal parts, with the same thickness M.S. sheet as per the existing size & shape including cutting, bending welding, drilling etc., including renewal of all nut & bolts sheet metal screws, mounting legs, rubber bushes, and cleaning & prepare the surface thoroughly, applying two coat of synthetic enamel paint over a coat of red oxide primer fixing of all components, brazing the refrigeration piping and shifting to its original position and connecting up all electrical connections and testing all as specified as directed. Note : Rate quoted is deemed to be inclusive of cutting, welding, brazing, sealing the refrigerant tubing, replacement of strainer, CTC, Nitrogen gas, Refrigerant gas, required to and from Transportion and Handling. M/L for spares will be measured and paid separately
100M&L for taking down the damage condenser fan blade ofwalkin cooler of any make and supply & fixing suitable new fan blade and testing & commissioning the unit.
101M&L for taking down the damaged blower unit of any make of walk in refrigiratorand supply and fixing of new blower unit of suitable type and testing & commissioning the unit.
102Supply and charging refrigerant R-22 complete one time for topping up or making full qty as per the pressure requirement of plant and testing for any leakage and rectifying the same as directed by Engineer in Charge and testing on full load condition for 8 Hrs period.
103Supply only compressor oil for carrying out repairs underrelevant items above.
104M&L for dismantling the defective induction motor of any make, any duty or any class of insulation from the bed, duly coupled with pump/ compressor, transporting to workshop, removing burnt out winding from stator/ rotor, rewinding with suitable gauge of super enamelled copper wire of approved make and replacing drive end and non drive end bearings, insulation materials, varnishing, heating, re-assembling, testing and commissioning for 3HP to 10HP capacities including replacing base frame bolts & nuts complete all as directed: Notes: (i) Motor removed for re-winding shall be overhauled completely and quoted rate is inclusive for the same.
105Supply only3 pole power contractor of the following capcity ranging up to 60 A operating voltage230 V/ 415 V AC 50 HZ.
106(a) ML 1.5including overload relay 1.5
107(b) MNX 9 including overload relay 9
108(c) MNX 18 including overload relay 18
109Supply and fixing in repairs overload relay with operating range 32 to 40 A
110M&L for taking down the defective split/ Window unit of the any capacity, shifting to work shop, taking out the defective unserviceable hermetically sealed compressor from the unit, replacing the compressor with new compressor of the same capacity, fixing to the unit inter connecting the refrigerating lines, flushing out the cooling coil & condenser, removal the coil & carbon thoroughly, cleaning with CTC, leak testing, pressure testing with Nitrogen gas, dehyderating, Vaccumissing, charging of Refrigerant gas, testing at work shop.Shifting to the location reinstalling the same in its Original position connecting up all etestion electrical, connection and Testing & Commissioning. All as specified as directed.Note : Rate quoted is deemed to be inclusive of cutting, welding, brazing, sealing the refrigerant tubing, replacement of strainer, CTC, Nitrogen gas, Refrigerant gas, required to and from Transportion and Handling. M/L for spares will be measured and paid separately
111M&L for complete repair to out door unit of Split type AC Unit of any size, including taking down all the components tinkering the rusted portion, renewal of complete rusted sheet metal parts, with the same thickness M.S. sheet as per the existing size & shape including cutting, bending welding, drilling etc., including renewal of all nut & bolts sheet metal screws, mounting legs, rubber bushes, and cleaning & prepare the surface thoroughly, applying two coat of synthetic enamel paint over a coat of red oxide primer fixing of all components, brazing the refrigeration piping and shifting to its original position and connecting up all electrical connections and testing all as specified as directed.Note : Rate quoted is deemed to be inclusive of cutting, welding, brazing, sealing the refrigerant tubing, replacement of strainer, CTC, Nitrogen gas, Refrigerant gas, required to and from Transportion and Handling. M/L for spares will be measured and paid separately
112M&L for taking down the damage condenser fan blade of 1.5/2 TR split/ Window type AC’s of any make and supply & fixing suitable new fan blade and testing & commissioning the unit.
113M&L for taking down the damaged blower unit of any make split/Window AC and supply and fixing of new blower unit of suitable type and testing & commissioning the unit.
114M&L for taking down the unserviceable temperature sensor probes and supply & fixing new sensor probe suitable for any type, make split/Window type AC’s and testing & commissioning.
115M&L for taking down the defective unserviceable printed circuit Board and S/F of new printed circuit board for any make split/window type AC unit.
116M&L for taking down the defective unserviceable sealed fan motor & S&F new fan motor ofthe same capacity & size to suit the split/window AC unit of any make and capacity of 1.5 / 2 TR all as per existing at site
117M&L for taking down the damaged air filter set and S/F of new air filter set for split/window type AC’s of 1.5 / 2TR capacity.
118M&L for taking down the defective unserviceable starting/running capacitors 80/100 MFD 230V / 50Hz and supply and Fixing the new starting capacitor of the same capacity to split / window type AC’s and testing.
119M&L for taking down the defective unserviceable starting relay and supply and fixing new rely suitable for 1.5/2TR Window / Split type AC’s and Testing.
120M&L for taking down the defective unserviceable Thermostatic switch and S/F new thermostatic suitable for window type AC’s and Testing.
121M&L for taking down the damaged drain pipe and S/F of new insulated drain pipe suitable for split type AC’s.
122M&L for taking down the defective capillary tube set and supply & Fixing new suitable capillary set for split type AC’s.
123M&L for taking down the rusted out door unit stand and supply & fixing the stand with required anchor fastner and nut & bolts and rubber bushes for 1.5 / 2 TR Split unit.
124M&L for taking down the burned out door unit fan motor and rewinding, overhauling renewal of worn out shaft & bushes, and fixing to the unit, of 1.5 / 2 TR Split units.
125M&L for taking down the defective remote control unit and S/F of new remote control unit for split/ window type AC of 1.5 / 2 TR of any make and testing.
126M&L for taking down the defective definite purpose magnetic contactor of the split/window AC’s of any make, and supply & fixing of new contactor of 240 VAC.30 Amps 50 Hz, and coil volt of 208/240V 50/60Hz and Testing.
127M&L for taking down the defective unserviceable sealed motor of indoor unit of any make split unit of 1.5/2 TR capacity and S/F new fan motor suitable for Split type AC’s.
128M&L for taking down the defective starting capacitor of split / window type AC’s and supply & fixing the new starting capacitor of 80/100 MFD 230V, 275SV-50Hz and Testing for 1.5/2TR AC Unit.
129M&L for taking down the burned wiring kit and supply & fixing and testing of new wiring kit suitable for 1.5/2TR split and window type Ac unit.
130M&L for taking down by disconnecting water connections and shifting elective water cooler to work shop, taking down the defective sealed compressor and replacing with new compressor, the work includes flushing the complete system condenser, cooling coil with Nitrogen, removal all carbon, oil & dirt, brazing & inter connecting the refrigeration lines, de-hydrating, purging with refrigerant, vaccumissing and charging of R22/ 134a Refrigerant and testing & commissioning and shifting to original location and connecting up the electrical & water connection for thecapacity of40/60/80120/150 Ltrs. capacity water coolers. All as specified as directed. (Note : Change of defective compressor will be measured in speate relevent items)
131M&L for charging the water cooler of the 40/60/80120/150 Ltrs capacitor including taking down, transporting to workshop flushing out the cooling coil, condenser, brazing the refrigerant lines, replacing of liquid line copper strainer, leak testing, purging with refrigerant, vaccumissing and charging of R22/R 134a gas, testing & commissioning and shifting to the location and connecting up the electrical & water connection.Complete all as specified as directed.
132M&L for painting the water cooler including scraping out the old paint prepare the surface, painting 2 coat of enamel paint over a coat of primer, the work including necessary putty, metal paste etc, and disconnecting from the position and refixing after painting for any capacity of the water coolers.
133M&L for the water cooler tank and cooling coil by dismantling the water cooler and carried out the lead soldering to cooling coil to the tank outer surface where ever the detached portion and rectify the leaks portion and re-assembly the water cooler of any capacity.
134M&L for taking down the damaged thermal insulation of the water cooler, and renew the thermal insulation as per the existing thickness and assembling the body with necessary sheet metal screws etc., for any capacity water coolers.
135M&L for taking down the defective starting relay and S/F of new starting relay for any capacity water cooler.
136M&L for taking down the defective overload relay and S/F of new over load relay suitable for any capacity water cooler.
137M&L for taking down the defective Running capacitor and Supply & Fixing new running capacitor 20/10 MFD, 440 VAC 50/60 Hz suitable water cooler.
138M&L for taking down the defective starting capacitor and Supply & Fixing new starting capacitor 60/80 MFD, 230V, 270SU-50 Hz for water cooler upto 120 Ltrs. Capacity.
139M&L for taking down the defective Running capacitor and Supply & Fixing new running capacitor of 25/36 MFD, 440 VAC, 50/60 Hz suitable for 150 Ltrs. Capacity water cooler.
140M&L for taking down the defective thermostatic switch and Supply and Fixing of new thermostatic switch for water coolers.
141S&F for Left/Punch cook for water cooler of any capacity.
142S&F for float valve for water cooler of any capacity
143M&L for taking down the damaged drain connections and drain pipe and S/F of new drain connection & pipe with necessary clamps, Nipple, coupling etc., for any capacity water cooler.
144M&L for taking down the defective unserviceable sealed fan motor and S/F new fan motor with suitable capacitor for water cooler upto 40/80, 60/120 /150 ltrs. Capacity.
145M&L for taking down the damaged condenser fan blade and supply and fixing of new fan blade suitable for 40/60/80/120/150 Ltrs water coolers.
146M&L for taking down the corroded air cooler condenser and supply and fixing of new air cooled condenser with necessary brackets and fixing arrangements including welding brazing etc., for water cooling 40/60/80/120/150 Ltrs. Capacity.
147M&L for taking down the corroded air cooled condenser and supply and fixing of new air cooled condenser suitable for 1.5 /2 TR Split Ac
148M&L for complete carryout the servicing to Split/ Window type AC’s including taking down from the position, dismantling the sheet metal parts, blowing out the dust, carryout the chemical cleaning to chocked cooling coil & condenser coil, by spray the dilated chemical cleaning agent, till remove complete chocking, flushing across the coils, cleaning all the sheet metal parts, filter, grill and fixing all the dismantled parts with sheet metal screws, lubricating the fan motor bush / bearing, checking all the electrical connections, renew any burned legs/ clip and fixing back to position and testing.(Note: Gas Charging if required will be measured and paid seperately).
149Supply and charging the refrigerator gas R-134A / R-34A /R-407/any environmental friendly refrigerant gascomplete all as specified and as directed.
150Supply and charging compressor oil suitable for AC"s, water cooler ,Refrigerator and deep freezer complete including testing etc, complete all as specified and as directed.
151Removing the old paint of the body of refrigerator of any capacity and making the body dent proof and preparing the surface and Painting the refrigerator with 2 coats of synthetic enameled paint of superior quality to match with existing paint with spray paintingcomplete all as specified and directed.
152S&F in replacement of existing UNSV sealed Compressor unit for Refrigerator of capacity 165 to 320 Ltrs including Gas charging.
153S&F in replacement of existing UNSV sealed Compressor unit for Water cooler of capacity 60 to 150Ltrs including Gas charging.
154S&F in replacement of existing UNSV sealed Compressor unit for Window/ Split AC of capacity 1/1.5/2 TR including Gas charging.
155S&F in replacement of existing UNSV sealed Compressor unit for Deep freezer of capacity up to 320 Ltrs including Gas charging.
156S&F in replacement of existing UNSV cooling Thermostat switch suitable for refrigerator/deep freezer of any capacity.
157M & L for replacement of old unsv fan motor with fan motor suitable for deep freezer of any capacityincluding all accessories complete all as specified and as directed.
158M & L for dismantiling old refrigiratior fo any size form the site given deposting to MES store yard and S & Fixingnew Refrigirator of capacity 310 Ltr, 145 V single phase including testing and commissioning complete all as specified and directed.
159M & L for attending routine complaitns of summer cooling applicances including rectificaito of minor defects, by taking out defective parts and replacement with new ones , including leakage arresting, cleaning flushing, gas charging etc includingchanging of minor parts complete all as specified and directed. Note :The complaints for the above works shall be registered by Contractor at the Refrigiration sec complaint cell of AGE E/M and tradesman shall be detailed from there on daily basis.(ii) Stationary required such as complaint book, Job cards etc shall be arranged by the contractor and proper record shall be maintaied by the contractor. (iii) Tools required for attending the complaint shall be arranged by the contractor. (iv) The rate quoted by the contractor for the above job shall be inclusive fo the cost of woks under note (i) to (iii) above. (v) The above complaint shall be completed within 12 Hrs of registration of the complaints (vi) The stores required for the works shall be issued and measured and paid separately under relivant items.
160M & L for laying Plain or corrugated steel sheets, any thickness in available sizes, on Walking cooler base/side wall all where found necessary including dismanlting old worn out cladding.
161Material and lbour for taking down complete old corroded, unserviceable window AC of 1.5 Ton capacity and depositing to MES Store and supply and fixing a new window AC of 1.5 Cpacity
162Supply , install , testing and commissioning of voltage stabilizer copper wound of capacity 4 KVA, automatic operation,single phase naturally air cooled indoor type, wall mounted triple boost type & designed for input variation between 170 volt to 270 volt AC with output voltage stabilised at 230 volt AC 50 Hz with accuracy +/- 2.5% and with inbuilt digital display for showing Voltage/ Amps of incoming and outgoing with selector switch with TDR of 2 to 3 minutes and high and low voltage cutoff complete all as specified and as directed.
163M&L for taking down the complete corroded sheet metal body of out door and indoor unit of split unit AC, supply and fixing testing and commissioning of new indoor, out door unit suitable 1.5 TR split AC the work includes dismantling the components and reassembly and fixing to the existing location and testing for any make of split unit.
164Strip opening of Rebomax Boiler Model No:- RX-061842 (2000) and RX_061843 (2000), 600 Kg/ Hr capacity installed at Laundary Plant 167 Military Hospital, Pathankot for complete servicing, overhauling and including replacement of existing old un-serviceable/ worn out parts and re-assembling the same after complete repair/overhauling including making all electric, fuel and water connections as required . (Note:- (i) Rate for fixing of replaced items deemed to be includinguded in this item. Replaced items shall be measured and paid seperately under respectively item of Sch "A"). (ii) Work will be carried out by Technical Expert/ Engineer Exesutive/ Rep of Original Equipment Manufacturer. (iii) Safety aspect is to be ensured for working team/ rep while working.(iv) Testing of Boiler shall be carried out at full load to the entire satisfaction of Engr-in-charge. (v) As far as possible/ availbale ISI marked spare parts/ items to be utilize for incorporation in the said work complete all as specified and directed.
165M&L for replacement of Main Coil RXA-06 made of seamless steel testing on full load all as directed includingrequisite electric/fuel/water connections. Make:- Thermax.
166M&L for replacement of existing u/s Economiser suitable for RXA-06 (2000). Make Thermax
167M&L for replacement of existing u/s Electrde suitable for RXA-06 (2000). Make Thermax
168M&L for replacement of existing u/s ignition tranformer 14 KVA, 440 volts/11 KV. Make Thermax
169M&L for replacement of existing u/s Photocell 8205. Make Thermax
170M&L for replacement of existing u/s Hylam packing bakelite. Make:- Thermax.
171M&L for replacement of existing u/s asbestos packing.
172M&L for replacement of existing u/s sequence controller MA 810. Make Thermax
173M&L for replacement of existing u/s HV Cable.
174M&L for replacement of existing u/s Fuel Pump AJ6. Make :- Sentac or equivalent
175M&L for replacement of existing u/s triplex pump piston (SP) make as per sample
176M&L for replacement of existing u/s DTC (Digital temperatue controller) controller make as per sample
177M&L for replacement of existing u/s gland washer for triplex pump make as per sample
178M&L for replacement of existing u/s valve sheet assembly make as per sample
179M&L for replacement of existing u/s sight glass size 50 mm dia and 4 mm thick fire proof make as per sample
180M&L for replacement of existing u/s Thermometer 0 to 150 degree centigrade make as per sample
181M&L for replacement of existing u/s pressure gauge 0 to 25 Kg/cm, 4 inch dia including back connection make as per sample
182M&L for replacement of existing u/s RTD assy make as per sample.
183M&L for replacement of existing u/s limit switch suitable for RXA-6 (2000) make as per sample
184Material and labour for replacement of existing u/s Nozzle 6.5 suitable for RXA-6 (2000) make as per sample
185Material and labour for replacement of existing u/s burner rod assy. make as per sample
186Material and labour for replacement of existing u/s steam blow down valve size 20 mm make as per sample
187Material and labour for replacement of existing u/s steam non return valve size 20 mm make as per sample
188Material and labour for replacement of existing u/s metallic brid hose pipe size 3/8 x 36 inch make as per sample
189Material and labour for replacement of existing u/s metallic brid hose pipe size 1/2 x 20 inch make as per sample
190Material and labour for replacement of existing u/s water level pressure switch make as per sample
191Material and labour for replacement of existing u/s steam pressure switch make as per sample
192Material and labour for replacement of existing u/s safety valve 25 mm make as per sample
193Material and labour for replacement of existing u/s electrode cap for burner make as per sample
194Material and labour for replacement of existing u/s super heater as per sample all as specified and directed.
195Material and labour for replacement of existing u/s asbestos teflon rope size 10 mm or required and directed. Make: Champion.
196M&L for replacement of existing u/s asbestos teflon rope size 5 mm or required and directed. Make: Champion.
197M&L for replacement of existing u/s cemented plaster with white cement complete all as specified and directed. Make: ACE
198Material and labour for replacement of existing u/s door gasket ofwashing machines of size and capacities 25/50/100/200 Kgs, drying tumbler 25/50 kgsas per sample all as specified and directed.
199M&L for repair/maitenance of hydaullic extractor top loading 25 kgs capacity including taking outof internal drum, soldering, refix and balancing of internal drum and replacement of base bearing, glands, gland cup, studs and top shut off handle of any type etc as per sample all as specified and directed.
200M&L for repair/maitenance of hydaullic extractor top loading 50 kgs capacity including taking outof internal drum, soldering, refix and balancing of internal drum and replacement of base bearing, glands, gland cup, studs and top shut off handle of any type etc as per sample all as specified and directed.
201M&L for repair/maitenance of slucing machine front loading 25 kgs capacityincluding taking out of internal drum, soldering, refix and balancing of internal drum and replacement of bearing, gland, gland cup and studs of any type etc as per sample all as specified and directed.
202M&L for repair/maitenance of washing machine front loading 50 kgs capacityincluding taking outof internal drum, soldering , refix and balancing of internal drum and replacement of bearing, gland, gland cup and studs of any type etc as per sample all as specified and directed.
203M&L for repair/maitenance of washing machine front loading 100 kgs capacityincluding taking outof internal drum, soldering , refix and balancing of internal drum and replacement of bearing, gland, gland cup and studs of any type etc as per sample all as specified and directed.
204M&L for repair/maitenance of washing machine top loading 200 kgs capacity including taking outof internal drum, soldering , refix and balancing of internal drum and replacement of bearing, gland, gland cup and studs of any type etc as per sample all as specified and directed.
205M&L for repair/maitenance of dry tumbler machine front loading 25 kgs capacityincluding taking outof internal drum, soldering , refix and balancing of internal drum and replacement of bearing, gland, gland cup, studs and wire mesh in bottom of machine any type etc as per sample all as specified and directed.
206M&L for repair/maitenance of dry tumbler machine front loading 50 kgs capacitiyincluding taking outof internal drum, soldering , refix and balancing of internal drum and replacement of bearing, gland, gland cup, studs and wire mesh in bottom of machine any type etc as per sample all as specified and directed.
207M&L for repair/maitenance of flat bed press including replacement of u/s internal wiring, checking of hydraullic system and other spares required to make press serviceable complete all as specified and directed.
208M&L for repair/maitenance of calandering machine including replacement of u/s internal wiring and other spares required to make serviceable complete all as specified and directed.
209M&L for repair/maitenance of Auto clave 30 kgs solidmachine including replacement of u/s internal wiring and other spares required to make serviceable complete all as specified and directed.
210M&L for repair/maitenance of Motressor steliser of size 1050 X 1200 X 2100 mm handle weight 150kgs solidmachine including replacement of u/s internal wiring and other spares required to make serviceable complete all as specified and directed.
211M&L for repair/maitenance of Air compressor reciprocating air cooledvaccum pump 5 HP with 200 ltr capacity air tank including replacement of u/s internal wiring, checking of compressor oil and other spares required to make serviceable complete all as specified and directed.
212M&L for repair/maitenance of water softening plant including replacement of spares required to make serviceable complete all as specified and directed. Note for Srl No.199-212: Extra spares required other than specified injob shall be measured and paid separately under items of this schedule.
213M&L for replacement of existing u/s limit switch 10 Amps, 1 NO + 1 NC, 500 volts as per sample complete all as specified and directed.
214M&L for replacement of existing u/s forward/ reverse mechanism of washing machine as per sample complete all as specified and directed.
215M&L for replacement of existing u/s ML contactor ML 1.5, 415 volts, 3 phase as per sample complete all as specified and directed.
216M&L for replacement of existing u/s ON/ OFF push button, AC 15: 415 V, 4 Amps, DC 13: 110 Volts, DC 0.5 Amps as per sample all as specified and directed.
217M&L for replacement of existing u/s Magnetic coil drain switch Type:- SLD, 415 volts, 50 Hz, Max. stroke:- 3.14 MM, Pull:- 6.75 Kg as per sample.
218M&L for replacement of existing u/s Electronic timer type ETR D2, 240 volts as per sample.
219M&L for replacement of existing u/s Indicators 2XVLIR, 130 Volts, 2.6 W as per sample.
220M&L for replacement of existing u/s ML 2 Contactor, 415 volts, 32 Amps as per sample all as specified and directed. Make : L&T.
221M&L for replacement of existing u/s door gasket ofwashing machines of size and capacities 25/50/100/200 Kgs, drying tumbler 25/50 kgsas per sample all as specified and directed.
222M&L for replacement of existing u/s spring for hydraullic extractor 25 kgs capacityas per sample all as specified and directed.
223M&L for replacement of existing u/s spring for hydraullic extractor 50 kgs capacityas per sample all as specified and directed.
224M&L for replacement of existing u/s bronze steam valve 15 mm, ISI marked as per sample.
225M&L for replacement of existing u/s bronze steam valve 20 mm, ISI marked as per sample.
226M&L for replacement of existing u/s bronze steam valve 25 mm, ISI marked as per sample.
227M&L for replacement of existing u/s bronze steam valve 40 mmISI marked as per sample.
228M&L for replacement of existing u/s bronze steam valve 50 mmISI marked as per sample.
229M&L for ball valve 50 mm dia gun metal as per sample. complete all as specified and directed.
230M&L for multiport valve for water softening plant make as per sample
231M&L for replacement of existing u/s V- Belts size B-65 complete all as specified and directed.
232M&L for replacement of existing u/s V- Belts size B-101 complete all as specified and directed.
233M&L for replacement of existing u/s V- Belts size B-71 complete all as specified and directed.
234M&L for replacement of existing u/s V- Belts size B-108 complete all as specified and directed.
235M&L for replacement of existing u/s V- Belts size B-78 complete all as specified and directed.
236M&L for replacement of existing u/s V- Belts size B-124 complete all as specified & directed.
237M&L for replacement of existing u/s V- Belts size C-96 complete all as specified znd directed.
238M&L for replacement of existing u/s V- Belts size B-96 complete all as specified and directed.
239M&L for replacement of existing u/s V- Belts size B-79 complete all as specified and directed.
240M&L for replacement of existing u/s V- Belts size B-120 complete all as specified and directed.
241M&L for replacement of existing u/s V- Belts size A-56 complete all as specified and directed.
242Material and labour for rewinding of existing unsv 3 Phase, 0.5 HP/ 0.37 KW , 50 Hz, 2800 RPM induction motor any make with super enameled copper winding wire ofgauge as per existingincluding cutting and getting out old US winding, sleeve work, varnishing with E class insulation varnish , threadingand making all electric connections including taking out and refixing at site all as specified and directed.
243All as per description of srl item 242 above but for 3 Phase, 2 HP/ 0.37 KW , 50 Hz, 2800 RPM
244All as per description of srl item 242 above but for 3 Phase, 5 HP/ 0.37 KW , 50 Hz, 2800 RPM
245All as per description of srl item 242 above but for 3 Phase, 10 HP/ 0.37 KW , 50 Hz, 2800 RPM
246Material and labour for replacement of existing u/s GI water tubing medium grade 15 mm dia. Incuding all fittings required at site complete all as specified and directed.
247All as per description of srl item 246 above but for 20mm dia pipe.
248All as per description of srl item 246 above but for 25mm dia pipe.
249All as per description of srl item 246 above but for 40mm dia pipe.
250All as per description of srl item 246 above but for 50mm dia pipe.
251All as per description of srl item 246 above but for 80mm dia pipe.
252M&L for replacement of existing u/s MS pipe medium grade 15 mm dia incuding all fittings/ fixture required at site complete all as specified and directed.
253All as per description of srl item 252 above but for 20mm dia pipe.
254All as per description of srl item 252 above but for 25mm dia pipe.
255All as per description of srl item 252 above but for 40mm dia pipe.
256M&L for replacement of existing un-serviceable/ perished metallic wheels with outer coverof cloth trollies including welding/ fabrication and testing on load complete all as specified and directed.
257M & L for welding / fabrication to the exsting u/s equipment of the machinery for re-strengthing to the existing assests including replacement of angle iron any size, channel, flat iron, MS sheet, nut, bolt and washers etc complete all as specified and directed.
258M&L for replacement of radiator of dry tumbler machine front loading 50 kgs capacity including soldering, brazing etc complete all as specified and directed.
259M&L for replacement of radiator of dry tumbler machine front loading 25 kgs capacity including soldering, brazing etc complete all as specified and directed.
260Taking out the old unserviceable radiator from the dry tumbler machine front loading 50 kgs capacity and taking it to work shop for overhauling & cleaning descaling with restore plus solution, removal of leakage, welding brazing & refixing it duly repaired etc complete all as directed.
261Taking out the old unserviceable radiator from the dry tumbler machine front loading 25 kgs capacity and taking it to work shop for overhauling & cleaning descaling with restore plus solution, removal of leakage, welding brazing & refixing it duly repaired etc complete all as directed.
262M&L for replacement of old u/s MCB four pole with RCCB four pole 40 amps, with 100 mA sensitivity, 415 volts complete all as specified and directed.
263M & L for replacement of old u/s MCB four pole with RCCB four pole 63 amps, with 100 mA sensitivity, 415 volts complete all as specified and directed.
264M&L for cleaning of treated water tank of RCC construction and of approx size 3.4x3.4x1.5 mof STPby bailing out the accumulated raw water at the bottom and removing the complete silt/sludge/dirt from the tank and disposing it away from site as directed, scrapping the tank inner walls and bottom with wire brush and cleaning the tank inner walls and bottom with the bleaching powder slurry completely incl applying one coat of white wash to entire tank externally complete all as directed Note: (a) The rate deemed to be inclusive of T&P and transportation required for disposal of sludge/dirt away from the site. (b) The cleaning of tank shall be performed once in three months all as directed.
265M & L for carrying out chemical analysis (BOD/COD) test of treated sewer water of STPfrom Govt authorised laboratory or PBTI lab chandigarh all as per CPCB/PPCB norms as directed . Note : The rate quoted is deemed to be inclusive of charges for testing, collection and transportation of water samples in sealed PVC container to test lab complete.
266a) pH
267b) TSS
268c)BOD 3 days
269d) COD
270e) Faecal Colifor
271M&L for chlorination of treated sewage water with Sodium hypochiorite solution (Grade-I) as per IS 11673-1992for treatment at Chlorine contact & treated water tank of STPfor maintining residual chlorineall as directed by manufacturers recommendations/ instructions Make: RMCO Sodium hypochlorite solution or equivalent approved make by GE.
272M&L for taking out existing any type pumpset/airblower for 2HP to 5HP capacity for servicing by disconnecting motor and blower/ pump set, pipe line and removing of all parts like bearing, bushes, impeller, shaft etc cleaning all surfaces and scales/ sludge/ dirt/formed inside/out side pumpset/blower etc Lubricating/ greasing at proper places and re fixing in position with all serviceable parts with motor incl painting with one coat of anti corrosive paint over red oxide primer and writing MES /SM No and testing and commissioningall as directed by Engr-in-charge.( Note -spares like bearings will be measured and paid separately against supply only)
273All as per description of srl item 278 above but for 7.5HP to 10HP capacity
274Supply only ball bearings for 2HP to 5HP capacity pumpsets/airblower
275All as per description of srl item 274 above but for 7.5HP to 10HP capacity
276Dismantling 50 mm bore unserviceable valves and Supply, fixing,testing and commissioning of butterfly valvesincl cutting, welding etc completeall as directed.
277All as per description of srl item 276 above but for 65mm bore
278All as per description of srl item 276 above but for 80mm bore
279M&L for dismantling the defective induction motor of any make & capacity 2 HP to 7.5 HP , any duty or any class of insulation from the bed, duly coupled with pump/ compressor, transporting to workshop, removing burnt out winding from stator/ rotor, rewinding with suitable gauge of super enamelled copper wire of approved make and replacing drive end and non drive end bearings, insulation materials, varnishing, heating, re-assembling, testing and commissioning of the following capacities including replacing base frame bolts & nuts complete all as directed:Notes: (i) Motor removed for re-winding shall be overhauled completely and quoted rate is inclusive for the same.
280supply and fix in replacement power contactor 3 pole of current carrying capacity suitable for range 2 HP to 5 HP rated motor with coil operating voltage 230 V/ 415 V AC 50 HZ.
281All as per description of srl item 280 above but for 7.5HP to 10HP capacity
282supply and fix in replacement Thermal oveload relay suitable for 2 HP to 5 HP rated motor.
283supply and fix in replacement Thermal oveload relay suitable for 7.5HP to 10 HP rated motor.
284Supply and fix in star-delta timer.
285Supply only common salt of 25 Kg bag
286Supply only (Calcium based granular disinfectant for water treatment, more stable than Chlorine Gas, and stronger than bleachingpowder, and sodium Hypochlorite) with chlorine content 65 to 70 % , packing in 45 kg drum complete all as specified and directed.
287Supply only stable bleaching power (SBP)(Calcium hypochloride)Grade I,availabilty Chlorine 34 % min,Stability 1/15 Max,moisture 0.3% max etc all as per IS.
288Cutting the tarmac/ hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
289M&L for heat shrinkable end termination joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 16 to 50 sq.mm.
290All as per Item above but for cable of size 3.5 core 70 to 120 sq.mm.
291All as per Item above but for cable of size 3.5 core 150 to 185 sq.mm
292Supply & fixing in repairs ofMCCBs of following current carrying capacity including necessary connecting terminals to bus bar, nut bolts etc complete all as directed .
293(i) 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 200-250 A rated
294(ii) 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 160-200 A rated
295(ii) 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 125A to 160 A rated .
296M & L for replacement of unsv/broken thermoplastic polycarbonate spring type locks suitable for panel locking (Mi DV 01 with Mi SR 4) complete.Make : Hensel
297Restretching of ACSR conductor of any size ofover head lines LT/HT on poles including binding with insulators, jointing jumpers etc including connections of incoming and out going cables complete all as specified and directed. Note: ACSRconductor Required for winding etc to be included in quoted rates.
298M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5 core 16 to 50 sq.mm.
299M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5 core 70 to120 sq.mm.
300M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5 core 150 to185 sq.mm.
301Dismantling unserviceable cross arms including clamps, bolts, nuts, washers etc from pole.
302Supply, fabricate and fix cross arms any size along with, brackets, clamps, bolts, nuts, washers, bracers etc incl. drilling holes, cold/hot complete and fixed to pole including one primer coat and one under and finishing coat of paint.
303Dismantlin of ACSR conductor of any size, from insulator etc from the structure/over head line all as directed.
304M&L replacement of ACSR conductor of any size as ordered by Engr-in-charge including tightening and bindingh with new binding wires to insulators all as directed.
305Dismantling insulators any type, size
306M&L pin type insulator vitreous, white, brown, or green insulator includig one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100 mm height, 65 mm dia for 1100 volts grade.
307Maintenance and servicing of DG set consistingof replacement of fuel filter, air filter and lub oil filter including replacement of eninge oil all as directed and testing on full connected load for the following capacity of DG Sets and any make as per OEM.Note: Engine oil will be measured and paid seperately.
308(a) DG Set 50 KVA
309(b) DG Set 62 to 100 KVA.
310M & L for replecement of existing unservicible Fan Belt and testing complete for the following capacity of DG Sets and any make as per OEM.
311(a) DG Set 50 KVA
312(b) DG Set 62 to 100 KVA.
313M & L for replecement of existing unservicible Hose Pipes with clamps and testing complete for the following capacity of DG Sets and any make: :-
314(a) DG Set 50 KVA
315(b) DG Set 62 to 100 KVA.
316Taking out the old unserviceable radiator from the DG set and taking it to work shop for overhauling & cleaning descaling with restore plus solution, removal of leakage, welding brazing & refixing it duly repaired etc complete all as directed for the following capacity of DG Sets and any make as per OEM.
317(a) DG Set 50 KVA
318(b) DG Set 62 to 100 KVA.
319Dismentling of self starter and supply and fix new selfstarter 12 V ofcapacity of OEM make complete all as specified and directed.
320M&L for repair and overhauling of unsv dynamo/alternator 12 V of any capacity DG set including repair/replacement unsv/defective spares such as field coil, armature winding, carbon bushes, clutch bushes and pinion assy complete all as specified and directed.
321M&L for repair and overhauling of unsv of battery charger of capacity 24 V including repair/replacement unsv/defective spares such as transformer, rectifier/diode plate, Ammeter, Voltmeter, selector switch, capsule fuse and neon indicator lamp.
322S&F in repair AVR with functions to adjust generator output voltage, prevent voltage hunting, set under frequency roll off knee point, set generator droop to 5% at full load, match AVR input to accessory output, set the over excitation cut off level, set intial frequency related voltage dip, over-voltage protection cut off level, maximum short circuit current with sensing input voltage range 170 - 250 V AC max, 50 -60 HZ frequency with output max upto 120 V DC, continuous current 2.7A & transient 6A for 10 sec including necessary control wiring complete from alternator to AVR complete testing & commissioning for DG sets of capacity 50 to 100 KVA
323All as per srl item above but for DG set capacity 50 to 100 KVA
324M & L for repair of Water pump of 50 to 100 KVA DG set including replacement of defective unsv spare part of any make and model and refix the same after repair complete all as specified and as directed
325M&L for Calibration of Fuel pumpincluding replacement of unsv/defective spares of 50 to100 KVA DG Set of any make and model complete all as directed.
326M&L for overhauling and calliberation of fuel injector assemblyincluding replacement of unsv/defective spares of 50 to 100 KVA DG Set of any make and model complete all as directed.
327S&F for replacement battery leads set, PVC insulated multisranded, copper conductorof min size 35 sqmm 1 mtr long each duly fixed with brass clamps, copper lugs suitable for DG setsof different capacities.
328M/L for replacement of coolant for radiator forDG set at various locations.Make: Servo/HP/Indian Oil.
329M/L for replecement of Lub Oil (Engine Oil) of grade 20W40 for Engine forDG set at various locations.Make: Servo/HP/Indian Oil.
330M & L for replacement of starter ring gear assembly for capacity50 to 110 KVA DG set.
331S&F in repair capacitor duty contactor with 1 No Aux contact 230V AC coil voltage suitable for minimum 10 KVAR capacitor.
332S&F in repair capacitor duty contactor with 1 No Aux contact 230V AC coil voltage suitable for minimum 25 KVAR capacitor.
333S&F in repair Double metalised paper and polypropylene technology(Mixed dielectric) capacitor cylindrical/box type for per KVAR power factor correction of440 V, 50 HZ rated of capacity20 to 25 KVAR.
334M&L in replacement of existing unserviceable conector of current caring range 25 A to 40 Amp (AC-3 duty at different places in APFC panels including required electrical connections with suitable size of single core pvc copper cable & testing all as directed
335M&L in replacement of existing unserviceable conector of current caring range 9 A to 18 Amp (AC-3 duty at different places in APFC panels including required electrical connections with suitable size of single core pvc copper cable & testing all as directed.
336M&L in replacement of existing unserviceable MCB 25-40 Amps TPN 415 volts at different places in LT paneles/APFC panels including required electrical connections & testing all as directed .
337M&L in replacement of existing unserviceable MCB 32-63 Amps TPN 415 volts at different places in LT paneles/APFC panels including required electrical connections & testing all as directed .
338Taking out the old unserviceable battery from the DG set and supply and fix new 12 V, 180AH maitenance free battery make Amron /Exide including testing and commissioning complete all as specified and directed.
339Disconnecting the inlet/outlet water connections and electric connections of Storagestorage type electric water heater of capacity 25 Ltrs capacity, taking down carefully from wall after unscrewing nut/bolts ,checking the outer body for any cracks and strip opening the same carefully for thorough inspection of serviceablity/functionality of parts such as internal tank, syphon assembly, thermostat switch, heating element, glass wool etc, servicing complete and re-assembling and re-fixing after repair,fixing to wall testing, installation and commissioning all as directed. Note: (a) The spares required for replacemeny shall be measured and paid under relevant Schedule items of Sch here-in-after.
340Supply only internal SS tank of storage type electric water heater of 25 ltr capacity complete with syphon –assembly, 1.5 KW/2.0 KW element , rubber gasket , thermostat switch , all as specified and directedfor carrying out repairs under relevant item No.339 . Note :- The tank shall be tested at site and shall be able to with stand requisite pressure . Necessary testing equipment shall be arranged by the contractor .Tank with stud type roundelement shall only be used . (Triangular element shall not be allowed .)
341Supply only syphon assembly made out of SS of 25 ltr capacity including necessary studs screws and rubber gasket/washers matching with existing/new inner tank complete all as spd and directedfor carrying out repairs under relevant item No.339
342Supply only thermostat switch ISI marked forstorage type electric water heater AC 230 volt adjustable range from 0-90 degree Celsius)for carrying out repairs under relevant item No.1
343Supply only cup/triangulartypestorage type electric water heater element AC 230 volt, of rating 1500/2000 wattfor carrying out repairs under relevant item No.339
344Supply only outer body suitable for 25ltrstorage type electric water heater made out of MS sheet factory made complete with fixing bracket matching with existingcomplete all as specified and directedfor carrying out repairs under relevant item No.339
345Supply only glass woolof 25ltrs capacitystorage type electric water heatercomplete all as specified anddirected for carrying out repairs under relevant item No.339
346Supply only indicator lamp square/roundtype suitable forstorage type electric water heater 25 ltr all as per sample AC 230 Voltfor carrying out repairs under relevant item No.339
347Supply and replacement cable flexible PVC insulated, PVC sheathed, copper conductor, 3 core 70/.0076mm.
348Supply and fixing sheet metal enclouser single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed.
349De-scaling ofstorage type electric water heater of capacity 25 ltr after taking down thestorage type electric water heater from wall, strip opening the assembly, de-scaling the syphon assembly and refixing the assembly and re-installation ofstorage type electric water heater complete all as directed.
350S&F PVC connection 15 mm size with PTMT nuts of length 450 mm ISI Marked all as specified and as directed.
351Replacement of spring loaded air release valve ISI marked suitable for 25ltrs capacitystorage type electric water heaters.
352Replacement of safety valve/ dead wt. valve ISI marked suitable for 25 Ltrs capacity storage type electric water heaters.
353Supply and replace pillar taps, cast copper alloy with capastan heads, chromium plated, screwed down high pressure with lettered ‘Hot or Cold’ with long screwed shanks and fly nuts, screwed for iron pipe and fixed fancy type of size 15 mm .
354Supply and fixing anchor bolt 12mmX100mm long complete all as spd and directed (Note:- Anchor bolt shall be grouted with hammer drill only)
355Preparing the old surface by rubbing/scratching the old paint and providing the two coats of synthetic enameled paint through spray paining of 25 ltrstorage type electric water heater.
356Supply and replace brass non return valve suitable for 25 ltrstorage type electric water heater of size 15 mm.
357Supply and replace bottom cover plate ofstorage type electric water heater of capacity 25 ltr complete with MS screw all as per sample.
358Dismantling of Insulated hot water storage tank of capacity up to 500 Ltrs connected Solar Evacuated collectors/flat collectors and cold water tank with GI fittings & PVC pipe connection. Servicing,Testing, Commissioning & descaling of Hot water storage tank removing of corrosion/dust, replacement of UNSV PVC pipe after re-fixing the same.
359Service and descaling of Solar Evacuated tube Collector/Flat collectors with sulphuric acid by forcefully injecting the hot chemical into collector for number of times to clean the Solar Solar Evacuated tube Collector/Flat Plate Collector and assembled the same.
360S & F in replacement of Evacuated tube collector for Solar Water Heater of capacity Upup 500 LPD of suitabale size as per sample approved by Engineer -in-charge on the gound.
361Replacement of heating element2/3 KW suitable for stand by back up supply to solar water heater.
362M & L for replacement of unserviceable stop valves and S & F stop valves , cast copper allow, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or fixed Size 15mm ISI mark.
363Dismantling old unserviceable storage type electric water heater and depositing it to MES store yard. Supply, install, testing and commissioning ofstorage type electric water heater of 25 ltr capacity, BEE 5 star rated suitable for 8 bar pressure with nano polymer coated tank, incoloy heating element, rust proof ABS body etc complete all as specified and directed.
364Disconnecting thewater connections and electric connections of Desert coolers of capacity 3000 CFM to 5000 CFM, taking down carefully from stand/ CC supports ,checking the outer body for any damage and strip opening the same carefully for thorough inspection of serviceablity/functionality of parts such as fan assembly with motor (blower assly),water pump, khas khas pad , control wiring , selector switch etc, servicing complete and re-assembling and re-fixing after repair,fixing to wall testing, installation and commissioning all as directed. Note: (a) The spares required for replacement shall be measured and paid under relevant Schedule items of Sch here-in-after.(b) Any other minor spares such as nut bolts, screws,piano switch, indication lamp replacement required is deemed to beincluded in quoted rate.
365Supply only wiring for desert cooler including all accessoriesall complete diected for carrying out repairs under relevant item.
366Supply only blower motor ofsingle way shaft 240 Volts 50 c/s of suitable capacityfor desert cooler of capacity 3000 CFM to 5000 CFM single way shaft 240 Volts 50 c/s complete all as specified and directed for carrying out repairs under relevant item.
367Supply only water circulation pump suitable for desert cooler of capacity 3000 CFM to 5000 CFM240 volts 50 c/s single phase complete all as specified and directed for carrying out repairs under relevant item.
368Supply only Khaskhas pad honey bee type (set of 3) for Desert Cooler of any capacity ( Set of three) complete all as specified and directed for carrying out repairs under relevant item.
369Removing the old paintfromthe body ofdesert cooler making the body dust proof and preparing the surface and painting the desert cooler with 2 coats of synthetic enamel paint of superior quality over a coat of Red Oxide primer all as specified.
370Removing the old rusted base tub of desert cooler of 3000 to 5000 cfm capacityand fabrication of base tray and top cover made of PGI sheet of minimum0.8 mm thick sheetand fixing in position using necessary nuts, bolts and washers all as specified and directed.
371S&F in replacement of existing UNSV galvanized iron top coverofminimum0.8 mm thick sheetper and providing new one of existing size, gauge and shape ,nuts and bolts suitable for 3000 to 5000 cfm capacity Desert Cooler complete all as specified and directed
372Material and labour in replacement of existing UNSVPVC front show grill complete with selector switch piano type switch and indicator etc as per requirement for 3000 to 5000 cfm capacityDesert Cooler complete all as specified and directed.
373Material and labour in replacement of Fan blade hub assly only for Blower motor of desert cooler made of alloy/Forged steel suitable for 3000 to 5000 cfm capacityDesert Cooler complete all as specified and directed
374Material and labour in replacement of Leg set complete for fixing blower motor for desert cooler complete with all necessary fixing/Fastening arrangements(As per sample) suitable for 3000 to 5000 cfm capacityDesert Cooler complete all as specified and directed
375Material and labour in replacement ofwater distributor and PVC pipe connection for water connection of desert cooler 3 piece (length not less than 35 cm each piece)(As per sample) suitable for 3000 to 5000 cfm capacityDesert Cooler complete all as specified and directed
376Material and labour in replacement of Capacitor of capacity 4mfd suitable for desert coolercomplete all as specified and directed
377Dismantling old defective desert cooler and depositing to MES store yard. Supply, install, test and commissioning of desert cooler electric driven, single phase of approx minimum size 575x575x800mm made out of 0.8 mm thick GI sheet for body, with water tank of capacity50 Ltr made out of 1 mm thick and with front grills and side direction grills, suitable for minimumair Delivery- ?4000 Cum/ hr, approx 450 mm sweep fan size with mild steel curved blades duly painted with synthetic anti corrosive paint, fitted to body including prewired electric 4 speed switch control and one 6Amps piano switch. Water immersed pump of suitable capacity 1300 RPMrated suitable for 230 volts, 50 Hz AC supply and one 6 Amps piano switch withfan motor of minimum capacity 105 watt, 1400RPM, 230 volts, 50 Hz and water inlet pipe with brass float valve of size 15mm and outlet with brass drain plug of 20mm .The pad of 3 sides shall be of honeycomb type, including standof minimum height 900 mm made out 25mmx25mmx3mm MS angle iron, duly coated with weather proof paint of black colour
378M & L for Insulation of M S Pipe with PUF slab up to 40 mm thick or EPF insulation 50 mm thick, with and including applying bituminuous compound and Aluminium cladding with 26 gauge sheet complete of up to 80mm size including dismanlting old worn out cladding.
379Dismantling old UNSV Deep Freezer & depositing to MES tore yard and Supply, installation, commis-sioning of Metal Top Deep Freezer single phase 240 volt, 50 Hz of size 300/320 Ltrs complete all as specified and directed.
380Note for all items: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail