| 1 | Taking down carefully copper/aluminium point wiring light, fan, socket or power complete, such as switches, ceiling roses,pendents, regulators, sockets etc. removing materials to store for keeping in safe costudy or for taking credit and making good disturbed surface of walls, floors etc.Complete all as specified and directed by Engineer-in-Charge. |
| 2 | Material & labour for Point wiring for one light point / fan point / bell point / 5 Amp socket outlet point (independent point), controlled by one, one way switch with 1.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) (using colour code as per IS) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing specifications)and sunk cast ironor pressed steel terminal boxes for mounting fittinglike switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of 1.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) as in earth wire(using green colour)and connected to common earth dolly, including making good of disturbed surface of cement plaster, whitewash/ distemper to match with original colour ; complete all as specified & directed by Engineer-in-Charge. |
| 3 | Material & labour for Point wiring for one light point / fan point / bell point / 5 Amp socket outlet point (independent point), controlled by Two , two way switches with 1.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) (using colour code as per IS) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface)and sunk cast ironor pressed steel terminal boxes for mounting fittinglike switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of 1.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) as in earth wire(using green colour)and connected to common earth dolly, including making good of disturbed surface of cement plaster, whitewash/ distemper to match with original colour ; complete all as specified & directed by Engineer-in-Charge. |
| 4 | All as per item No 2.00 above but one 5 Amp 3 pin socket outlet onindependent board complete. |
| 5 | All as per item No 2.00 above but one 5 Amp 3 pin socket outlet onthe sameboard with other switches complete. |
| 6 | Material & labour for Point wiring for one 16 Amp socket outlet point (independent point), controlled by one, one way switch with 2.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) (using colour code as per IS) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface)and sunk cast ironor pressed steel terminal boxes for mounting fittinglike switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of 2.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) as in earth wire(using green colour)and connected to common earth dolly, including making good of disturbed surface of cement plaster, whitewash/ distemper to match with original colour ; complete all as specified & directed by Engineer-in-Charge. |
| 7 | Material & labour for Point wiring for one light point / fan point / bell point / 5 Amp socket outlet point (independent point), controlled by one, one way switch with 1.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FRLS) (using colour code as per IS) drawn into and including medium grade PVC conduit concealed (not less than 25 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing specifications)and including sunk Metal flush box , cover plate with suitable size of frame for fixing/mounting fittinglike modular switches, sockets,including one continuous run of 1.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FRLS) (using green colour) as in earth wire and connected to common earth dolly,and making good of disturbed surface of cement plaster, whitewash/ distemper to match with original colour ; complete all as specified & directed by Engineer-in-Charge. Note :-The quoted rates under this itemincludes the cost of Metal flush box , cover plate with suitable size of frame for fixing modular switches/sockets/regulator etc. |
| 8 | Material & labour for Point wiring for one light point / fan point / bell point / 5 Amp socket outlet point (independent point), controlled by two , two way switcheswith 1.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FRLS) (using colour code as per IS) drawn into and including medium grade PVC conduit concealed (not less than 25 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing specifications)and including sunk Metal flush box , cover plate with suitable size of frame for fixing/mounting fittinglike modular switches, sockets,including one continuous run of 1.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FRLS) (using green colour) as in earth wire and connected to common earth dolly,and making good of disturbed surface of cement plaster, whitewash/ distemper to match with original colour ; complete all as specified & directed by Engineer-in-Charge. Note :-The quoted rates under this itemincludes the cost of Metal flush box , cover plate with suitable size of frame for fixing modular switches/sockets/regulator etc. |
| 9 | All as per item No 7.00 above but one 5 Amp 3 pin socket outlet onthe same board with other switches complete. |
| 10 | All as per item No 7.00 above but for one 5 pin 5 amps socket outlet on the independent board. |
| 11 | Material & labour for Point wiring for 15 Amp socket outlet point (independent point), controlled by one, one way switch with 2.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FRLS) (using colour code as per IS) drawn into and including medium grade PVC conduit concealed (not less than 25 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing specifications)and including sunk Metal flush box , cover plate with suitable size of frame for fixing/mounting fittinglike modular switches, sockets,including one continuous run of 2.50 Sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FRLS) (using green colour) as in earth wire and connected to common earth dolly,and making good of disturbed surface of cement plaster, whitewash/ distemper to match with original colour ; complete all as specified & directed by Engineer-in-Charge. Note :-The quoted rates under this itemincludes the cost of Metal flush box , cover plate with suitable size of frame for fixing modular switches/sockets/regulator etc. |
| 12 | Supply & fixing for switch piano 5 amps flush type single pole one way complete all as specified and directed by Engineer-in-Charge. |
| 13 | Supply & fixing for switch piano 5 amps flush type single pole two way complete all as specified and directed by Engineer-in-Charge. |
| 14 | Supply & fixing for socket outlet flush type 2 in one5 pin 6 amps complete all as specified and directed by Engineer-in-Charge. |
| 15 | Supply & fixing for switch piano 15 amps flush type single pole one way complete all as specified and directed by Engineer-in-Charge. |
| 16 | Supply & fixingfor socket outlet 2 in 1, 5 pin 16 amps flush type complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply & fixing for Modular plate switch 6 amps single pole one way one module complete all as specified and directed by Engineer-in-Charge. |
| 18 | Supply & fixing for Modular plate switch 6 amps single pole two way one module complete all as specified and directed by Engineer-in-Charge. |
| 19 | Supply & fixing for Modular plate switch 16 amps single pole oneway one module with indicator complete all as specified and directed by Engineer-in-Charge. |
| 20 | Supply & fixing for modular plate socket6 Amps 2 in 1, 5 pin combined shuttered type two module complete all as specified and directed by Engineer-in-Charge. |
| 21 | Supply & fixing for modular plate socket16 Amps 2 in 1, 5 pin combined shuttered type two module complete all as specified and directed by Engineer-in-Charge. |
| 22 | Supply & fixing for modular fan regulatorstep type 120 Watt two modulecomplete all as specified and directed by Engineer-in-Charge. |
| 23 | Supply & fixing for Ceiling rose surface bakelite 65 mm x 50mm, two to three terminals with back plate of 3mm thick bakelite laminated hylem sheet of suitable size ; complete all as specified and directed by Engineer-in-Charge. |
| 24 | Supply & fixing forlamp holder PVC/ polycarbonate type with back plate suitable for batten fittingscomplete all as specified and directed by the Engineer in Charge. |
| 25 | Supply & fixing in repairs of ding dong bellAC 230 V single pole fixed over and including and suitable size sunk cast ironor pressed steel terminal boxes covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws complete all as specified and directed by Engineer-in-Charge. |
| 26 | Supply & fixing in repairs bell push flush type single pole 5 Amps; complete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply & fixing in repairs sheet metal enclosure single pole and neutralwithtwo pin and earth plug and socket with & including one single pole 415 volts MCB 20 amps 10KA ;complete all as specified and as directed by the Engineer-in-Charge. |
| 28 | Supply & fixing in repairs MCB single pole 240 Volts, 50Hz,vrupturing capacity10 kA, C curve , conforming to IS 8828 of rating 6 to 32 Amps complete all as specified and directed by Engineer-in-Charge. |
| 29 | Supply & fixing in repairs MCB double pole240 Volts, 50Hz,vrupturing capacity10 kA, C curve , conforming to IS 8828 of rating 40 to 63 Amps complete all as specified and directed by Engineer-in-Charge. |
| 30 | Supply & fixing in repairs MCB double pole240 Volts, 50Hz,vrupturing capacity10 kA, C curve , conforming to IS 8828 of rating 100 Amps complete all as specified and directed by Engineer-in-Charge. |
| 31 | Supply & fixing in repairs factory made Sheet metal EnclouserDistribution Board single pole and neutral , 4 way 240 volt with double door, IP - 43 &IK-09 protection system with having 200Amps 2 Nos bus bar for neutral bar and earth bus bar, DBsfixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring typecomplete all as specified and directed by Engineer-in-Charge. |
| 32 | Supply & fixing in repairs factory made Sheet metal EnclouserDistribution Board single pole and neutral,8 way 240 volt with double door, IP - 43 &IK-09 protection system with having 200Amps 2 Nos bus bar for neutral bar and earth bus bar, DBsfixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring typecomplete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply & Fixingin repairs Distribution Boarddouble Doormade out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 12 waywith IP-43 and IK-09 protection, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified and directed by the Engr-in-Charge. Note : cost of removing old wooden box and making good of surface as existing specifications i.e. brick work, plastering, whitewash/colour/ distemper etc is included in quated rate)complete all as specified. |
| 34 | Supply & fixing in repairs MCCB Incomer distribution board double door vertical type made out of CRCA MS sheet surface with insulated material like polyester or with epoxy powder coating surface mounting TPN 4 way, 415 volts with copper bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB and IP 43 - IK 09protection with and including 100 Amp 36 KA 4 pole MCCB with thermal - magnetic setting and Icu = Ics = 100% , including suitable type MCb with blank plate complete all as specified. Note :- The cost of removing old wooden/steel any type box and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quoted rate) |
| 35 | Material and labour in repairs submain wiring with two single core PVC insulated multi stranded copper conductor cable FR of size 6 Sqmm 1100 volt grade (ISI marked ) drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 25 mm dia) along with fittings and accessories all fixed concealed on wall and surface on ceiling, with one 6 Sqmm single core multi stranded copper conductorFR as earth continuity to common earth doly as earth wire (Green colour) complete all as specified and directed by the Engineer in Charge. Note :Two runs of main wire and one run of earth wire with PVC conduit shall be measured and paid as one length. |
| 36 | Material and labour in repairs submain wiring with two single core PVC insulated multi stranded copper conductor cable FR of size 10 Sqmm 1100 volt grade (ISI marked ) drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 25 mm dia) along with fittings and accessories all fixed concealed on wall and surface on ceiling, with one 10 Sqmm single core multi stranded copper conductorFR as earth continuity to common earth doly as earth wire (Green colour) complete all as specified and directed by the Engineer in Charge. Note :Two runs of main wire and one run of earth wire with PVC conduit shall be measured and paid as one length. |
| 37 | Supply & Fixing in repairswall /ceiling mounting LED 18 Watt pride plus/smart line tube light fitting complete withall acessories 1x18 Watt LED , with CCT of 6000k suitable for domestic application, 240 Volts, 50 Hz, and internally pre-wired with & including 1.5 sqmm twin twisted flexible cable copper conductor and connection complete all as specified and directed by the Engr-in-Charge. |
| 38 | Supply & Fixing in repair wall /ceiling mounting LED 9 Watt tube light fitting complete withall acessories 1x9 Watt LED ,with CCT of 6000k suitable for domestic application, 240 Volts, 50 Hz,and internally pre-wired with 1.5 sqmm twin twisted flexible cable copper conductor and connection complete all as specified and directed by the Engr-in-Charge. |
| 39 | Supply & Fixingin repairs decorative Gate light fitting made up of high grade unbreakable polycarbonate material suitablefor 9 watt LED lamp (B-22 base) with &including oneLED bulb 9 watt with accessories ; complete all as specified and directed by the Engr-in-Charge. |
| 40 | Supply & Fixing in repairs electronic ballast suitable for 1 X TLD, 36 watt / 36 watt PLL, type EBP 136 TLD, 240 volts 50 / 60 Hz ; complete all as specified and directed by the Engr-in-Charge. |
| 41 | Supply & Fixingin repairs energy saving new generation 10 watt LED built up, 6000kbulk head luminaire with opal diffuser light fitting complete with all acessories and connection complete all as specified and directed by the Engr-in-Charge. |
| 42 | Supply & Fixingin repairs of security light fitting LED 25 Watt aluminum pressure dia cast housing with touched glass cover IP-66 protectionIncludingsuitable sizeand accessories complete mounted including connection with & including 3 core PVC insulated overall sheathed flexible cable with muyltistranded copper conductor of size not less than 1.5 Sq mm from celing rose to fitting terminalcomplete all as specified and directed by the Engr-in-Charge. |
| 43 | Supply & Fixingin repairs fan regulator electronic step type (5 step)socket size and making all necessary connections complete all as specified and directed by the Engr-in-Charge. |
| 44 | Material & Labour in repairs earthing complete with galvanised earth plate electrode 600mm X 600mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 metres below ground level) with top edge of earth plate not less than 1.5metres below normal ground level, connected to galvanised earth lead wire 4mm dia by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No.3 of MES SSR2009 , Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge,50mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel round bars @ 150mm both ways center to center with suitable lifting handle to cover, earth pit made of PCC 1:3:6 type C-1, GI protection pipe light grade 15 mm bore up to 7.5metres length from earth electrode & engraving of earth marking on nearby building with cement mortar (1:4) plate size 200mm X 150mm X 15mm & painting of earth result etc. including testing ;complete all as specified and directed by the Engineer-in-Charge.Note : - (i) Earth lead and protection pipe beyond 7.5 m shall be measured and Paid separately. (ii) On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt. |
| 45 | Supply and fixing in repairs ceiling mounting fitting LED type 36 Watt fitted in 2 X 2 ceiling including PVC wire upto 1.5 mtr from ceiling rose to fittingcomplete all as specified and directed by Engineer in Charge. |
| 46 | Supply & Fixing in repairs25 mm bore light grade galvanised iron tubing with all necessary GI fittings as in protection pipe of cable, fixed to pole or laid under floor / ground / under road crossings for protection of cable ; complete all as specified and directed by Engineer-in-Charge. |
| 47 | Supply and fixing in repairs 1100 volt grade heavy duty electric power cable 10 sqmm twin corePVC insulated Aluminium solid conductor screwed with inner seathing of PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1metre apart including 4 mm suspension wirewith & including drawn through 25mm dia PVC conduit heavy duty , fixed to walls / polscomplete all as specified and directed by Engineer in Charge.complete all as specified and directed by Engineer-in-Charge. |
| 48 | Supply & Fixingin repairs LED flood light fitting 50 Watt with high pressure die cast housing IP65 protection single phase supply including connection with PVC wire ; complete all as specified and directed by Engineer-in-Charge. |
| 49 | Supply & Fixing in repairs post top lantern LED fitting 15 Watt including LED bulb high grade unbreakable polycarbonate suitable for LED bulb including connection with PVC wire ; complete all as specified and directed by Engineer-in-Charge. |
| 50 | Supply & fixing in repairs GI bracket 1.2 metres long, made of GI pipe medium grade of 40 mm dia, 2 x clamps made of Flat iron 40 mm x 6 mm Incl nuts,bolts & washers, painting,fixing on wall of the building/ pole complete all as specified and directed by the Engineer in Charge. |
| 51 | Supply & Fixingin repairs bell push, Modulartype, single pole 5 amps , one module; complete all as specified and directed by Engineer-in-Charge. |
| 52 | Supply & Fixing in repairsLED Blub9 Watt Pintype 220 Volts including connection ; complete all as specified and directed by Engineer-in-charge. |
| 53 | Supply & Fixing in repairsCeiling light fitting 12 Watt as per sample including connection; complete all as specified and directed by Engineer-in-charge. |
| 54 | Supply & Fixing in repairsLED Blub9 Watt Thread type 220 Volts including connection ; complete all as specified and directed by Engineer-in-charge. |
| 55 | Material & Labour for binding of loose wire in any numbers /of any size by using cable ties and cable clips flexible PVC pipes and PVC casing and caping of suitable size as required on site . Note :- Flexible PVC pipe and casing and caping will be measured and paid separtely. |
| 56 | Supply & Fixing in repairsflexible pipe 25mm dia ; complete all as specified and directed by Engineer-in-charge. |
| 57 | Supply & Fixing in repairsflexible pipe 40mm dia ; complete all as specified and directed by Engineer-in-charge. |
| 58 | Supply & Fixing in repairsPVC Casing / Caping25mmincluding connection ; complete all as specified and directed by Engineer-in-charge. |
| 59 | Supply & Fixing in repairsPVC Casing / Caping 20mmincluding connection ; complete all as specified and directed by Engineer-in-charge. |
| 60 | Supply & Fixingin repairsHylam sheet 7\" x 4\" including screw complete all as specified and directed by the Engr-in-Charge. |
| 61 | Supply & Fixingin repairsHylam sheet 9\" x 11\" including screw complete all as specified and directed by the Engr-in-Charge. |