| 1 | PHASE I |
| 2 | M&L for digging a trench of dia 0.45 mtr, depth 0.45 mtr (Minimum) and refilling with good soil and cattle manure in the ratio 4:1, mixing , leveling, racking, supply and planting of Bottle Palm (3-4 feet tall) and maintenance by regular watering, dewatering, de-weeding, filling/adding mixture of good soil and manure as required cutting/shaping adding fertilizer for a period of twenty four months (after period of completion of work). |
| 3 | M&L for digging a trench of dia 0.45 mtr, depth 0.45 mtr (Minimum) and refilling with good soil and cattle manure in the ratio 4:1, mixing , leveling, racking, supply and planting of Ashoka Tree (3-4 feet tall) and maintenance by regular watering, dewatering, de-weeding, filling/adding mixture of good soil and manure as required cutting/shaping adding fertilizer for a period of twenty four months (after period of completion of work). |
| 4 | M&L for digging a trench of dia 0.45 mtr, depth 0.45 mtr (Minimum) and refilling with good soil and cattle manure in the ratio 4:1, mixing , leveling, racking, supply and planting of Duranta (10 inch-12 inch) and maintenance by regular watering, dewatering, de-weeding, filling/adding mixture of good soil and manure as required cutting/shaping adding fertilizer for a period of twenty four months (after period of completion of work). |
| 5 | S&F mild steel work such as angle iron post and struts, flat iron in fencing including cutting as making round shaped including wielding with proper overlapping and wielding MS plate with angle iron bottom as directed drilling holes notching for wire etc embedded in concrete fixed vertically conforming to Fe290 grade E-165 complete (for tree guards) complete all as specified and directed. |
| 6 | S&F welded steel wire fabric n.exc 4Kg/Sqm supplied and fixed complete to steel member complete all as specified (for tree guards)complete all as specified and directed. |
| 7 | Surface dressing n.exc 15 cm deep as in any type of soil complete all as specified and directed. |
| 8 | Excavation in trenches n.exc 1.5 mtr wide and not exc 1.5 mtr deep for foundation etc or for shaft, wells, cess pits, man holes, pier hole etc n.exc 10 Sqm on plan for getting out in any type of soil, complete all as specified |
| 9 | Cement concrete 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete all as specified. |
| 10 | Walling of random rubble stone masonry brought up to course well bonded, bedded and solidly hearted, built in cement mortar (1:6) including providing weep holes complete all as specified (if PCC bond stone used in lieu of stone bond, the same shall be measured and paid separately) complete all as specified and directed. |
| 11 | Precast cement concrete Type C-1 (1:3:6) (20mm graded aggregate) as in bond stones set in cement mortar 1:6 with joints to match complete all as specified and directed. |
| 12 | Plain cement concrete 1:2:4 type B-1 (using 20mm graded aggregate) as in coping benching including slightly rounded or chamfered angles as directed including necessary form work and finishing the exposed surfaces complete, all as specified. |
| 13 | Flush pointing to random rubble walling uncoursed in CM (1:3) complete all as specified. |
| 14 | Extra over stone walling for hammer dressing to face stone and dressing of face beds and joints as specified of random rubble walling, uncoursed or brought upto course, hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 40mm for granite or trap stone, all as specified. |
| 15 | Hardcore (broken stone or boulders) of gauge n.exc 63mm, deposited, spread and leveled in layers n.exc 15cm thick watered and rammed to a true surface complete all as specified and directed. |
| 16 | M&L 100mm thick plain cement concrete 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in sub base floor concrete all as specified. |
| 17 | M&L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed. |
| 18 | M&L for Machine pressed precast concrete interlocking paver block any shape, any colour and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade with grey cement and pigment complete complete all as specified and directed. |
| 19 | Excavation over areas n.exc 1.5m deep and getting out any type of soil complete all as specified and directed. |
| 20 | M&L PCC 1:2:4 type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in floor 40mm thick complete all as specified. |
| 21 | Formwork to edges of concrete flats, break in floors, opening, in concrete walls, floors, roofs and sides of RCC/PCC bands in wall, horizontal or sloping and similar work finished surfaces of concrete all as specified. |
| 22 | RCC type B-1, 1:2:4 (using 20mm graded crushed stone aggregate) as in beam & lintels over 1.50m span complete all as specified. |
| 23 | TMT steel bars 10mm dia and over as in reinforcement, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooping end and binding with MS wire (annealed) not less than 0.9mm dia, complete all as specified. |
| 24 | Ditto as above but 5mm dia and over upto and including 10mm in stirrups, spacers and binders complete all as specified. |
| 25 | Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified. |
| 26 | Rendering 15mm thick in cement mortar 1:3 on fair faces of brick work to receive wall tile complete all as specified. |
| 27 | Supply only water proofing compound (Liquid) |
| 28 | M&L PCC 1:3:6 Type C-1 using 20mm graded crushed stone aggregate as in plinth protection concrete surface finished even and smooth without using extra cement complete all as specified and directed. |
| 29 | Supply and fixed Glazed ceramic coloured tile (300mmx200mmx7mm thick) set and jointed in neat cement slurry and pointed in white or coloured cement to match as in vertical surface complete all as specified and directed. |
| 30 | Supply and fixed non skid ceramic coloured tile 7 to 8mm thick area of each tile exc 0.06 sqm but not exc 0.11 sqm in floor set and jointed in neat and cement slurry and pointed in white or coloured cement in match including 15mm thick screed bed with CM 1:4 complete all as specified. |
| 31 | Supply and erecting in position stain less steel bench (03 seater) of size 1.8m x 0.60m x 0.80m height minimum weight 26 Kg. Make : Nilkamal Brand Garden Deco complete all as specified and directed. |
| 32 | Excavating in post holes (or similar holes) each n.exc 0.50 Cum, getting out , returning, filling in and ramming earth or broken rubble mixed and earth around, in layers not exceeding 25 Cm any type of Soil and removing surplus soil to distance not exc 50m and making good the surface complete all as specified and directed. |
| 33 | M&L PCC Type C-2 1:3:6 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 34 | S&F MS work as in posts and struts including cutting tops to shapes as directed, drilling holes, notching for wire etc. flat iron fillets (for securing wire mesh) including all necessary drilling, bolting or reverting etc and similar work conforming to Fe 290 Grade E-165 complete all as specified and directed. |
| 35 | S&F MS work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS 1161-1979 grade St-240 complete all as specified and directed. |
| 36 | S&F mild steel plates Plain or chequred channel squre cut or notched (ordinary and counter shunk) forming holes, without any attachment grade Fe-410-W-E-250 quality A complete all as specified and directed. |
| 37 | Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of a colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 38 | Pre-Painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified. |
| 39 | M&L for preparation of new steel surface, applying a coat of red oxide/zinc chrome primer and two coat of synthetic enamel paint to steel surfaces of any description, over 10cm in width or girth, not otherwise described including preparation of new or previously untreated surfaces of steel complete all as specified and directed. |
| 40 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 Cm complete all as specified and directed. |
| 41 | Removing excavated material n.exc 250m and depositing where directed at a level n.exc 1.5m above the starting pointcomplete all as specified and directed. |
| 42 | Forming embankments including raising (or lowering) earth, spreading in layers n.exc 30cm thick watering, ramming/rolling and finishing to required size, shape etc n.exc 1.5m high from base complete all as specified and directed. |
| 43 | M&L for preparation of new plaster surface of wall and applying two coats of cement base paint complete all as specified and directed. |
| 44 | S&F single phase monoblock submersible pump set of capacity 2HP (1.5KW) including DOL starter for fountain and for gardening sprinkler system all as specified and directed by Engr-in-Charge, Model: KOSI 225 Make Kirloskar Brothers Ltd. |
| 45 | Providing services for maintenance of plants/trees etc for deploying well experienced staff (mali)-01 Nos for all days of month (including Sunday/Holiday) from 0800 hrs to 1700 hrs from the date of completion of work. The maintenance includes by regular watering, replacing dead plant, de-weeding, filling/adding mixture of good soil and manure as required, cutting shaping and keeping tree guards well in position etc. complete all as specified and directed.Note: 1. Quoted Rates shall be deemed inclusive for provision of stand by staff for holiday/sunday.2. Maintenance staff will be controlled by contractor and supervised by JE incharge on daily basis for their attendance and deployment. |
| 46 | S&F water fountain circular 12W LED light Body material stainless steel colour temp range 2700-3000K to be fixed below the fountain nozzle of 25mm dia with 3 core 1.5 sqmm wire 1.5m in length all as specified and directed by Engr-in-Charge. |
| 47 | S&F fountain water proof 5-10W LED light made of stainless steel with 5mm clear toughened glass wire for main supply cable 3 core 1.5 sqmm 1.5m in length all as specified and directed by Engr-in-Charge. |
| 48 | S&F for adjustable jet straight fountain nozzle valve brass chrome plated sprinkler head of size 25mm all as specified and directed by Engr-in-Charge. |
| 49 | M&L for tubes medium grade galvanized with all fitting laid in tranches of size 50mm all as specified and directed by Engr-in-Charge. |
| 50 | M&L for gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed of size 50mm dia all as specified and directed by Engr-in-Charge. |
| 51 | M&L for gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed of size 40mm dia all as specified and directed by Engr-in-Charge. |
| 52 | M&L for tubes medium grade galvanized with all fittings laid in tranches of size 40mm all as specified and directed by Engr-in-Charge. |
| 53 | Sand cushioning for 8cm before laying the cable and then after laying the cable 15cm width trenches for protection of cable including punning down complete all as specified.Note:- Thickness of sand cushioning shall be the thickness after punning down. |
| 54 | M&L earthing complete with galvanized steel earth plate electrode 600mm x 600mm x6mm thick buried directly ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level connected to and including GI earth lead wire 4.00mm dia by means of GI thimbles, bolts, nuts, check ruts and washers and protected by provision of GI pipe medium grade, 1.5mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with lugs 02 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.7mtr long placed on top edge of earth plate, common salt and charcoal filling test point made out of phosphorous bronze with fixing arrangement funnel wire mesh and earth work in hard/dense soil, returning filling, in the removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-1 and connection to earth test point all as specified and testing on completion. |
| 55 | Supplying, laying, jointing and testing in trenches/ductes or fixed to wall/poles or passed through pipe 1100 volts grade armoured, heavy duty LT XPLE cable with stranded aluminum conductor or normal cross section area 6 sqmm 2 core complete all as specified. |
| 56 | Steel metal enclosure for DCS (double door) suitable for MCB SPN, 4 way, 240 volts with 200 Amps rated busbar complete all as specified. |
| 57 | Supply and fixing 8 watt LED garden light with inbuilt one meter pole having diffuser complete with all accessories internally prewired and including connecting up with suitable size twin core twisted flexible copper conductor cable with all as specified make:- Havells/wipro/bajaj or equivalent. |
| 58 | S&F thermoplastic cable junction boxes for 6 sqmm cable of size 139x119x70 with two terminal and mounting it on the poles/pipes for garden lights with IP 55 protection with membranes and terminals for cable entry with all suitable supports clamps nuts and washers all as specified and completed. |
| 59 | Brick covering to cables as mechanical protection with common burnt clay building bricks (old size bricks) sub class ‘B’ bricks complete all as specified. |
| 60 | Point wiring complete with stranded copper conductor 1.5 sqmm size (nominal area) PVC insulated unsheathed FRLS cable 1100 volts grade conforming to IS:694 drawn in and including medium duty concealed PVC conduit with fittings conforming to ISI mark not less than 20mm dia and making all joints water proof complete all as specified. |
| 61 | Time switch 230 volt single phase, 20 Amps rating with connector fitted inside steel enclosure complete all as specified and directed. |
| 62 | PHASE II |
| 63 | Providing services for maintenance of plants/trees etc for deploying well experienced staff (mali)-01 Nos for all days of month (including Sunday/Holiday) from 0800 hrs to 1700 hrs from the date of completion of work. The maintenance includes by regular watering, replacing dead plant, de-weeding, filling/adding mixture of good soil and manure as required, cutting shaping and keeping tree guards well in position etc. complete all as specified and directed.Note: 1. Quoted Rates shall be deemed inclusive for provision of stand by staff for holiday/sunday.2. Maintenance staff will be controlled by contractor and supervised by JE incharge on daily basis for their attendance and deployment. |