Survey, Design, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of 63 Kva Sub Station At Bharat Nagar ( Stp-9 ) Under Nrcp ( Goi ) In District Udhampur-2 9 Mtr. Long St Pole ( St-410 Sp-33 ) 3 50 Mm² Ab ( Ht ) Cable ( 3X50 + 1X70mm² ) ( 3C+Earth ) 4 Heat Shrinkable Outdoor Cable Termination Kit 5 Suspension / Tension Clamp With Eye Hook 6 Galvinized Nuts And Bolts. 7 Danger Plates With Clamps 8 Anti-Climbing Device With Clamps 9 Earthing Complete Bygi Rod 20 Mm, 2.5 Mtr Long Through G.I. Strip 25X3 Mm 10 Painting Of 9 Mtr St Poleswith One Coat Of Red Oxide Paint. 11 Painting Of 9 Mtr St Poles With Two Coat Of Aluminium Paint. 12 Cement Bottoming 1:2:4 Mix As Per Rec Standards, 0.5 Cum / Pole 13 Mid Span Straight Through Jointing Kit For 11 Kv Abc 14 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 15 Survey, Design, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of 63 Kva Sub Station At Bharat Nagar ( Stp-9 ) . 16 11 / 0.433Kv, 3-Phase 63 Kva Distribution Transformer With Bimetallic Terminal Connectors Energy Level-2, Aluminium Wound And With Lv Cable Box Havingdetachable Aluminium Gland Plate 17 Gapless Surge Arrestor 9Kv, 10Ka, La With Polymer Housing Station Type 18 11Kv Go Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type 19 11 Kv Horn Gapfuse Set 3 Phase 200A 20 120 Mm² Single Core Cable, 1.1Kv Grade, Pvc Insulated Alumnium Stranded Conductor Frls Type 21 9 Mtr. Long St Pole ( St-410 Sp33 ) 22 11Kv Disc Insulators ( Polymeric 45Kn ) Creepage Distance 320 Mm With Tension Fittings 23 11Kv Pin Insulator ( Polymeric ) With Pins ( 12Kv, 5Kn ) Creepage Distance 320Mm 24 Gi Channel / Angle / Flat Of Sizes Including Clamps 25 Galvinized Nuts And Bolts. 26 Lt Distribution Box For 63 Kva Dtr With Mccb For Incomer And SfuS For Outgoing Circuits. 27 Cement Bottoming Of St Poles In 1:2:4 Mix As Per Rec Standards, 0.5 Cum Per Pole 28 Painting Of Sub Station St Poles / Cross Arms / Clamps With One Coat Of Red Oxide And Two Coats Of Aluminium Paint 29 Danger Plates With Clamps 30 Gi Barbed Wire For Anti Climbing 31 Earthing Of Substation --Excavation Of Earth Pit Of Dia 650 Mm & Depth 3000 Mm, Installation Of Earthing Pipe Of 40 Mm Nominal Bore & 4Mm Wall Thickness & Length 2.5 Mtr Long As Per Is 1239. Gi Strip For Neutral Earthing Of Size 50 Mm X 6 Mm & 32Mm X 3Mm For Connection Of Transformer Body, G.O Set & Lightening Arrestor As Per Is 2629 / 85, Gi Nuts & Bolts, Refilled With Earth Enhancement Materials And Earth Chamber With Rcc Slab Cover. 32 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 33 Wedge Connectors / Pg Clamp 34 Lt Prodigy Meter 35 Survey, Design, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 2 No. 11 Kv Tapping Point / Isolation Points At Mid Span For Creation Of 63 Kva Sub Station At Bharat Nagar ( Stp-9 ) . 36 9 Mtr. Long St Pole ( St-410 Sp-33 ) 37 Gi V Cross -Arm With Top Bracket Including Clamps 38 Gi Channel X-Arm Including Clamps And Angle For Braces 39 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical Type. 40 0.05 Acsrconductor Rabbit 41 Pg Clamps For 50Mm²acsr Conductor 42 11Kv Disc Insulators ( Polymeric 45Kn ) Creepage Distance 320 Mm With Tension Fittings 43 11Kv Pin Insulator ( Polymeric ) With Pins ( 12Kv, 5Kn ) Creepage Distance 320Mm 44 Galvanized Nuts And Bolts 45 Painting Of 8 Mtr St Poles With One Coat Of Red Oxide Paint. 46 Painting Of 8 Mtr St Poleswith Two Coat Of Aluminium Paint. 47 Danger Plates With Clamps 48 Anti-Climbing Device With Clamps 49 Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5Cum / Pole 50 Earthing Complete Bygi Rod 20 Mm, 2.5 Mtr Long Through G.I. Strip 25X3 Mm 51 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 52 Survey, Design, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Improvement Of Generation Colony Feeder Forcreation / Installation Of 63 Kva Sub Station At Bharat Nagar ( Stp-9 ) 53 9 Mtr. Long St Pole ( St-410 Sp-33 ) 54 120 Mm² Ab ( Ht ) Cable ( 3X120+ 1X95mm² ) ( With Earthing ) 55 Heat Shrinkable Outdoor Cable Termination Kit 56 Suspension / Tension Clamp With Eye Hook 57 Galvinized Nuts And Bolts. 58 Danger Plates With Clamps 59 Anti-Climbing Device With Clamps 60 Earthing Complete Bygi Rod 20 Mm, 2.5 Mtr Long Through G.I. Strip 25X3 Mm 61 Painting Of 9 Mtr St Poles With One Coat Of Red Oxide Paint. 62 Painting Of 9 Mtr St Poleswith Two Coat Of Aluminium Paint. 63 Cement Bottoming 1:2:4 Mix As Per Rec Standards, 0.5 Cum / Pole 64 Mid Span Straight Throgh Jointing Kit For 11 Kv Abc 65 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete