Repair And Maint Of Window/ Split Acs And Other Summer Appliances At Af Stn Under Ge Avadi, avadi-Tamil Nadu

Military Engineer Services-MES has published Repair And Maint Of Window/ Split Acs And Other Summer Appliances At Af Stn Under Ge Avadi. Submission Date for this Tender is 01-08-2022. Air Conditioner Tenders in avadi Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

32914319
Corrigendum : Repair And Maint Of Window/ Split Acs And Other Summer Appliances At Af Stn Under Ge Avadi
Open Tender
Indian
Tamil Nadu
avadi
01-08-2022

Tender Details

Repair And Maint Of Window/ Split Acs And Other Summer Appliances At Af Stn Under Ge Avadi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Jul-2022 8936 Corrigendum Other 25-07-2022
2 25-Jul-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-08-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR AND MAINT OF WINDOW/ SPLIT ACs AND OTHER SUMMER APPLIANCES AT AF STN UNDER GE AVADI
Sl. No. Item Description
1Testing the leakagein system, arresting the leakby vacumising the system, dehydration andcharging therefrigerent R-22 /R-32 into the system including replacement of strainer and capillary tube made out of copper complete suitable for 1.5 TonWindow Air conditioner all as directed by Engr-in-charge.
2Testing the leakagein system, arresting the leakby vacumising the system, dehydration andcharging therefrigerent R-22 /R-32 into the system including replacement of strainer and capillary tube made out of copper complete suitable for 1.5 Ton Split Air conditioner all as directed by Engr-in-charge.
3Testing the leakagein system, arresting the leakby vacumising the system, dehydration andcharging therefrigerent R-22 /R-32 into the system including replacement of strainer and capillary tube made out of copper complete suitable for 2.0 Ton Split Air conditioner all as directed by Engr-in-charge.
4Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for Split type AC, 1.5 ton capacity of any make / model complete all as specified and as directed.
5All as per the item 4above but1.5Ton capacity WindowAir conditioner
6All as per the item 4above but2.0 Ton capacity SplitAir conditioner
7Taking down the existing unserviceble Condenser coil and taken on credit and replacing with new Condenser coil suitable forSplit AC,1.5toncapacity of any make / model complete all as specified and as directed.
8Taking down the existing unserviceble Coolingcoil and taken on credit and replacing with new Coolingcoil suitable forSplit AC,1.5toncapacity of any make / model complete all as specified and as directed.
9Taking down the existing unserviceble Condenser coil and taken on credit and replacing with new Condenser coil suitable forSplit AC,2.0 toncapacity of any make / model complete all as specified and as directed.
10Taking down the existing unserviceble Coolingcoil and taken on credit and replacing with new Coolingcoil suitable forSplit AC,2.0 toncapacity of any make / model complete all as specified and as directed.
11Taking down the existing unserviceble Condenser coil and taken on credit and replacing with new Condenser coil suitable forWindow AC,1.5toncapacity of any make / model complete all as specified and as directed.
12Taking down the existing unserviceble Coolingcoil and taken on credit and replacing with new Cooling coil suitable forWindow AC,1.5toncapacity of any make / model complete all as specified and as directed.
13Removing and pump down the split AC of cap 1.5 & 2.0 Ton and refixing including shifting the same all as directed by Engr-in-charge.
14Taking down the existing unserviceble indoor unit fan motor and taken on credit and replacing with new indoor unit fan motor suitable forSplit AC,1.5toncapacity of any make / model complete all as specified and as directed.
15Taking down the existing unserviceble outdoor unit fan motor and taken on credit and replacing with new outdoor unit fan motor suitable forSplit AC,1.5toncapacity of any make / model complete all as specified and as directed.
16Taking down the existing unserviceble indoor unit fan motor and taken on credit and replacing with new indoor unit fan motor suitable forSplit AC,2.0 toncapacity of any make / model complete all as specified and as directed.
17Taking down the existing unserviceble outdoor unit fan motor and taken on credit and replacing with new outdoor unit fan motor suitable forSplit AC,2.0 toncapacity of any make / model complete all as specified and as directed.
18Dismandling and taking down U/S fan motor, Supply and fix newfan motor for 1.5 Ton window AC all as directed by engr-in-charge.
19Taking down the existing window type AC, 1.5 ton capacity of any make / model from its position and cleaning the AC externally and servicing the AC including cleaning of condensor, filter, cooling coil, base bottom and fins, with soap water, checking of electrical wiring,ensure smooth functioningand re-install and reconnect the AC unit in its exising location after proper cleaning of the place and testing and commissioning complete all as specified and as directed.
20Servicing the split type AC, any capacity of any make / modelcleaning the AC externally and servicing the AC including cleaning of condensor coil without removing the outdoor unit,and filter, cooling coil base bottom and fins,with soap water, checking of electrical wiring, after proper cleaning of the AC and testing and commissioning complete all as specified and as directed.
21S&F in replacement PCB suitable for 1.5 TonACas per site requirement all as directed
22S&F in replacement PCB suitable for 2.0 TonACas per site requirement all as directed
23S& F in replacement of copper tubing set 1/4" and 1/2" suitable for Split AC incl PUF insulation and connected accessories complete all as directed
24S& F in replacement of copper tubing set 3/8" and 5/8" suitable for Split AC incl PUF insulation and connected accessories complete all as directed
25Supply and fix in replacement starting relay suitable for 1.5Ton A/C all as directed.
26Supply and fix in replacement starting relay suitable for 2.0 Ton A/C all as directed.
27Supply and fix in replacement wiring kit suitable for 1.5Ton A/C all as directed
28Supply and fix in replacement wiring kit suitable for 2.0Ton A/C all as directed
29Supply and fix in replacement running capacitor 36mfd 230/415 Voltall as directed .
30All as per item No. 29 but 50 mfd 230/415 all as directed
31Supply and fixi in replacement starting capacitor 80/100mfd 230/415 Volt
32S&F Pvc drain pipe size 15mm /20mm suitable for A Call as directed
33S&F PUF insulation for copper tubing suitable for splitAC all as directed
34Supply and filling refrigerent R-22, suitable for Window AC/water cooler of any type all as directed
35Supply and filling refrigerent R-32 suitable for SplitAC/water cooler of any type all as directed
36Taking down the existing unserviceble Over load Protector and taken on credit and replacing with new Over load Protector suitable for Window AC / Split AC,1.5 ton capacity of any make / model complete all as specified and as directed.
37Taking down the existing unserviceble Thermostat switch and taken on credit and replacing with new Thermostat switch suitable for Window AC / Split AC,1.5toncapacity of any make / model complete all as specified and as directed.
38Supply and fix U/S Remote control sensor and digital device complete set with remote suitable for split type AC, any capacity.
39Supply and fix U/S Air filter suitable for window / Split type AC, 1.5 ton capacity.
40Supply and fix U/S Front grill suitable for window type AC, 1.5 ton capacity.
41Supply and fix U/S Oscillating motor / device to change direction of air flow suitable for split type AC, any capacity.
42Supply and fix U/SMagnetic coil suitable for split type AC, anycapacity.
43Taking down the existing unserviceble GI bracket including all accessories and taken on credit and replacing with new GI bracket including all accessories suitable to fix out door unit of split type AC, of any make / model complete all as specified and as directed
44Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for water coolerof capacity 80 ltrs any make / model complete all as specified and as directed.
45All as per item No. 44 above but suitable for 120 ltr cap water cooler
46All as per item No. 44 above but suitable for 150 ltr cap, water cooler
47Taking down the existing unserviceble copper condenser coil and taken on credit and replacing with newopper condenser coil cap 80 ltrs water cooler of any make / model complete all as specified and as directed
48All as per item No. 47 above but suitable for 120 ltr cap water cooler
49All as per item No. 47 above but suitable for 150 ltr cap, water cooler
50Renewal with fabricated sheet metal of base where compressor and condensor are mounted alongwith legs by base plate of sheet metal 2mm thick of size 600mm x 600mm with frame of angle iron 25mm x 25mm x 6mm alround,x 20mm widh legs of mild steel pipe 40mm dia, 150mm long with bottom sealed with MS sheet 2mm thick and spray painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer after due preparation of surfaces for water coolers of capacity 80 ltrs / 120 lits / 150 lits complete all as specified and as directed.
51Taking down the existing unserviceblecondenser fan motor and taken on credit and replacing with new condenser fan motor any capwater cooler of any make / model complete all as specified and as directed
52Cutting thesuction/ discharge tubes ofthecompressor lineand Flushing, vacuuming and charging of water cooler of any make / modelwith refrigerantgas, after dehydration as per standard practice, including detection of leaks and arresting the same by welding / brazing complete of capacity 80 ltrs water cooler all as specified and as directed.
53All as per item No. 52 above but suitable for 120 ltr cap water cooler
54All as per item No. 52 above but suitable for 150 ltr cap water cooler
55Taking down the existing unserviceable strainer and capillary tube and taken on credit and replacing with new strainer and capillary tube suitable for water coolerof any make / model / cap complete all as specified and as directed.
56Taking down the existing unserviceable short circuited wires and terminal clipsand taken on credit and replacing with new wires and terminal clips suitable for water coolerof any make / model / cap complete all as specified and as directed.
57Taking down the existing unserviceable PVC water inlet pipe for replacement newPVC pipe, transparent,heavy duty 20mm dia water inlet pipe for water cooler complete all as specified and as directed.
58Taking down the existing unserviceable PVC pipe as drain out pipe for replacement newPVC pipe, heavy duty 25mm dia drain out pipe laid on walls / floor for water cooler complete all as specified and as directed.
59Supply and fix in replacement Starting Relay suitable for water cooler of any capacityall as directed
60S&F in replacement running capacitor cap 30 Mfd suitable for water cooler of any capacityall as directed
61S&F in replacement starting capacitor cap 60 to 80Mfd suitable for water cooler of any capacityall as directed
62All as per item No. 61 above butcap of 40 to 60 mfd .
63S&F in replacement thermostate switch suitable for water cooler of capacityall as directed. .
64S&F in replacement OLP suitable for water cooler of any capacityall as directed.
65Supply and fix in replacement new fan motor suitable for water cooler any capacityall as directed.
66Supply and fix U/S chromiam coated brass bip Tap for water cooler 15mm size, straight type
67Supply and fix U/S chromiam coated brass bip Tap for water cooler 15mm size, angle type with round disc
68Supply and fix U/S drain tray (stainless Steel) for water cooler of any capacity
69Supply and fix U/S 15 mm ball valves high pressureof PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed and minium weight 142 gms. For water cooler
70Preparation of surface by removing dust, tinkering, applying metalputtywherever necessary and paintingwith two coats of synthetic enamelpaintby spray painting of the Refrigerator 340 ltrsallasspecified and as directed.
71All as per item No. 70 above butcap of Refrigerator 210 to 285 ltrs .
72All as per item No. 70 above butcap of Refrigerator 300to 320 ltrs .
73Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for digital inverter refrigerator of any make / model and capacity 340 lits complete all as specified and as directed.
74All as per item No. 73 above but cap of Refrigerator 300 to 320 ltrs
75All as per item No. 73 above but cap of Refrigerator 210 to 285 ltrs
76Cuttingthesuction/ discharge tubes ofthecompressorlineand flushing, vacuuming and charging of refrigerator / freezerof any make / modelwith refrigerantgas (R-12/R-404), after dehydration as per standard practice, including detection of leaks and arresting the same by welding / brazing complete Cap of Refrigerator 340 ltrs all as specified and as directed.
77All as per item No. 76 above butcap of Refrigerator 300to 320 ltrs .
78All as per item No. 76 above butcap of Refrigerator 210 to 285 ltrs .
79Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for Deep Freezer of capacity 300 to 320 lits of any make / model complete all as specified and as directed.
80All as per item No. 79 above but cap of Deep Freezer 400 to 425ltrs
81Cuttingthesuction/ discharge tubes ofthecompressorlineand flushing, vacuuming and charging of refrigerator / freezerof any make / modelwith refrigerantgas (R-12/R-404), after dehydration as per standard practice, including detection of leaks and arresting the same by welding / brazing complete Deep freezer any capacity all as specified and as directed.
82Taking down the existing unserviceable digital electronic circuit board and taken on credit and replacing with new digital electronic circuit board suitable for digital inverter refrigerator of any make / model and capacity complete all as specified and as directed.
83Taking down the existing unserviceable digital electronic circuit board and taken on credit and replacing with new digital electronic circuit board suitable for Deep freezer of any make / model and capacity complete all as specified and as directed.
84Taking down the existing unserviceable strainer and capillary tube and taken on credit and replacing with new strainer and capillary tube suitable for refrigerator / deep freezer of any capacityany make / model complete all as specified and as directed.
85Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for Deep freezers of any make / any capacity any model complete all as specified and as directed.
86Relay withOLP suitable for Deep freezer of any capacity .
87Thermostat switch suitable for Deep freezer of any capacity .
88Condensing motor suitable for Deep freezer any capacity .
89Starting capacitor 40 Mfd to 60 Mfd suitable for Deep freezer any capacity .
90Running capacitor 4 Mfd suitable for Deep freezer .
91Deep freezer door hinges with spring, screw etc suitable for freezer of any capacity .
92Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for refrigerators of any make / any capacity any model complete all as specified and as directed.
93Magnetic door gasket suitable for refrigerator of any capacity
94Freezer (cooling coil) suitable for refrigerator of any capacity
95Freezer door set suitable for refrigerator of any capacity .
96Thermostat switch with knob
97Relay box type suitable for refrigerator of any capacity .
98Relay open type suitable for refrigerator of any capacity .
99Timer switch suitable for refrigerator of any capacity .
100Blower motor suitable for refrigerator of any capacity .
101Running capacitor 4 Mfd suitable for refrigerator.
102Door lock with key in duplicte suitable for refrigerator of any capacity .
103Pigmy lamp screw / pin type with holder suitable for refrigerator of any capacity .
104Ice box tray suitable for refrigerator of any capacity .
105Vegetable tray suitable for refrigerator of any capacity .
106Bottletray suitable for refrigerator of any capacity .
107Shelves of inner panel suitable for refrigerator of any capacity .
108Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for Three phase ductable type Split AC, 5.5 ton capacity of any make / model complete all as specified and as directed.
109Testing the leakagein system, arresting the leakby vacumising the system, dehydration andcharging therefrigerent R-407A into the system including replacement of dryer filter complete suitable for 5.5 TR ductable type SplitAir conditioner all as directed by Engr-in-charge.
110Taking down the existing unserviceble Dischargevalve and taken on credit and replacing with new Discharge valve suitable for ductable type SplitAC 5.5 toncapacity of any make / model complete all as specified and as directed.
111Taking down the existing unserviceble Suction valve and taken on credit and replacing with new Suction valve suitable for ductable type Split AC 5.5 toncapacity of any make / model complete all as specified and as directed.
112Taking down the existing unserviceble Copper Condenser coil and taken on credit and replacing with new Copper Condenser coil suitable for ductable type Split AC 5.5 toncapacity of any make / model complete all as specified and as directed.
113Taking down the existing unserviceble Copper Evoperator coil and taken on credit and replacing with new Copper Evoperator coil suitable for ductabletype Split AC 5.5 toncapacity of any make / model complete all as specified and as directed.
114Taking down the existing unserviceble blower fan motor and taken on credit and replacing with new blower fan motor suitable for ductable type type SplitAC 5.5 toncapacity of any make / model complete all as specified and as directed.
115Supply and Top up of refrigerent gas R-407A of 5.5 ton ductabletype Split AC
116Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for voltage stabilizers of capacity 5 kVA / 4 kVA / 3 KVAof any make / model complete all as specified and as directed.
117Main transformer
118Transistorised electronic relay.
119Electronic PC circuit plate having diodes, condensers etc.,
120Voltmeter 0-300 Volts
121High / low voltage cut-off relay
122Time delay relay
123Output terminal contacts
124Socket outlet 5 pin 5 / 15 Amps
125Disconnecting and dismantling of RO plant of capacity 200LPH/ 250LPH / 500 LPHetc.,and servicing / overhauling, cleaning of sand / carbon / micro filter / membrane filmtech, check water leakage in filters and pipe, re-installing, reconnecting, testing and commissioning for proper and smooth functioning complete all as specified and as directed. Note :-Spares as required shall be measured and paid separately.
126Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for RO plant of capacity200LPH/ 250 LPH / 500 LPHcomplete all as specified and as directed.
127Raw water pump 0.50HP.
128Sand / carbon filter vessel 1054
129Sand bag 10 kg as 1 unit
130Fine Sand bag 10 kg as 1 unit
131Silex 10 kg as 1 unit
132Pebbles 10 kg as 1 unit
133Carbon bag 450IV 10 kg as 1 unit
134Multi port valve 20NB
135Dozing pump
13620 inch housing filter
13720 inch filter spun
13820 inch wound
139Antiscalant liquid
140High pressure pump (CRI) 2-100
14140-40 membrane housing
142End cup
143End cup "O" ring
144Saddles and straps
145Membrane (Filmtech), (hydro nautics)
146Membrane connecter
147Auto electric panel
148UPVC pipe 20mm dia and accessories
149Ultra violet media 250LPH
150Clip forUltra violet media
151Membrane cleaning liquid
152Disconnecting and dismantling of RO water purifier of capacity 15LPH / 50 LPHetc.,and servicing / overhauling, cleaning of sand / carbon / micro filter / membrane filmtech, check water leakage in filters and pipe, re-installing, reconnecting, testing and commissioning for proper and smooth functioning complete all as specified and as directed Note:- Spares as required shall be measured and paid separately.
153Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for RO plant of capacity 15 LPH / 50 LPHcomplete all as specified and as directed.
154Carbon granules filter
1555-5 membrane and housing assembly .
156Pressure pump 48 V
157Adaptor 48 V
158Carbon black filter.
159Micron filter
160Dismantling and removing of domestic water purifier (Aqua 200) filters fixed on wall and connected to water coolers at various locations, replacement of filters, re-installing, reconnecting, testing and commissioning for proper and smooth functioning complete all as specified and as directed.
161Supply &Fix for Sub main wiring with 2x 4 Sqmm size PVC insulated unsheathed single core multistranded copper conductor cable ISI marked for working voltage 1100 volts grade, drawn in toand includingPVCconduit and conduit accessories , including 4.0 sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to earth dolly and to be terminated and including taking down the old wiring complete all as specified and as directed.
162Supply &Fix for Sub main wiring with 2x 6 Sqmm size PVC insulated unsheathed single core multistranded copper conductor cable ISI marked for working voltage 1100 volts grade, drawn in toand includingPVCconduit and conduit accessories , including 6.0 sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to earth dolly and to be terminated and including taking down the old wiring complete all as specified and as directed.
163Supply & fixing single pole andneutral metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 A including taking down the old enclosure
164Taking down the existing unserviceable PVC 3 core 2.5 sqmm copper cable and taken on credit and replacing with new PVC 3 core 2.5 sqmm copper cable suitable for Water cooler / Refrigerator / Deepfreezer complete all as specified and as directed.
165Taking down the existing unserviceable PVC 3 core 4 sqmm copper cable and taken on credit and replacing with new PVC 3 core 4 sqmm copper cable suitable for Split AC /Geyser complete all as specified and as directed.
166Taking down the existing unserviceable MCB SP 5A to 32A and taken on credit and replacing with new MCB SP 5A to 32A suitable for Split AC complete all as specified and as directed.
167Taking down the existing unserviceable switch socket outlet 2 in 1, 3 pin, 6 and 16 A flush type universal and taken on credit and replacing with new 2 in 1 16A flush type socket complete all as specified and as directed.
168Supply and fix U/S 15 A plug top for water cooler, refrigerator,and geyser
169Supply and fix U/S 15 A metal glad plug top for water cooler, refrigerator,and geyser
170Material and labour forU/S switch piano, flush type single pole one way 16 Amps
171Supplyand fix forU/S socket outletpiano, flush type 3 pin,16 Amps
172Material and labour forU/S modularswitchone way 16 Amps 1 module
173Supplyand fix forU/S modular socket 6A / 16A - 2 / 3 pin combined 2 module.
174Taking down electricwater heater/ geysers of capacity 25ltrs from its mounting place for repair, re-assembling and refixing the same after repair and testing complete all as specified and as directed by Engineer-in-charge.
175All as per srl item No.114 here in before geyser of capacity 50 ltrs Note : (i) 114 & 115 spares Items replaced shall be measured separatly. (ii)Any damage if ooccured during the process of cleaning the geyser will be made good by contactor at no extra cost.
176S&F in replacement of heating element of 1.5 KW ratingdouble tube typewith cup type of circular /traingle shape includingrubber washerssuitable to fitin the existing geyser without any water leakage completeall as specified and as directed by Engr-in-Charge .
177S&F in replacement of heating element of 2 KW ratingdouble tube typewith cup type of circular /traingle shape includingrubber washerssuitable to fitin the existing geyser without any water leakage completeall as specified and as directed by Engr-in-Charge .
178S&F in replacement of the heat proof rubber PVC gasket suitable for the different make of 25 litres capacitygeysers as per side requirement complete, all as specified and as directed by Engr-in-Charge-.
179All as per item No. 118 here in before but suitable for capacity 50ltrs.
180S&F appretus plate (Geysers assemly) suitable for existing Geysers of Cap 25 Leters of copper r/brash complete with nuts and bolts and rubber washer complete all as specified and directed
181S&F appretus plate (Geysers assemly) suitable for existing Geysers of Cap 50 Leters complete with nuts and bolts and rubber washer complete all as specified and directed
182S&F in replacement of vertical non return valve 15 mm dia GM as per side requirement complete, all as specified and as directed by Engr-in-Charge . ISI mark
183S&Fstainless steelinner tank 18 gauge heavy duty in replacement of steel inner tankhaving pressure bearing capacity 4Kg/Cm.sq. suitable tothe existing25 ltrscapacity geysers. complete, all as specified and as directed by Engr-in-Charge .
184S&Fcopperinner tank 18 gauge heavy duty in replacement of copper inner tankhaving pressure bearing capacity 4Kg/Cm.sq. suitable tothe existing25 ltrscapacity geysers. complete, all as specified and as directed by Engr-in-Charge .
185S&Fstainless steelinner tank 18 gauge heavy duty in replacement of steel inner tankhaving pressure bearing capacity 4Kg/Cm.sq. suitable tothe existing50 ltrscapacity geysers. complete, all as specified and as directed by Engr-in-Charge .
186All as per serial items No 125 here in before but copper inner tank suitable for 50 ltrscapacity geysers.
187S&F in replacement the thermostat for the geysers 25Ltrs capacity as per site requirement complete, all as specified and as directed by Engr-in-Charge .Make DASS PASS/THETA/Bajaj/Vvinus
188All as per serial items No 127 here in before but suitable for 50 ltrscapacity geysers.
189S&F in replacement of safety valve/high pressure valve 15mm,as per side requirement completeall as specified and as directed by Engr-in-Charge . ISI marked.
190Supply and fixing in replacement of theinsulatingmaterial i. e. glass wool. complete, all as specified and as directed by Engr-in-Charge .
191S&F in replacement chromium plate copper connecting pipe 450 mm long with two brass nut and nylon washer suitable for 15mmdia pipe and connecting up complete, all as specified and as directed by Engr-in-Charge .
192S&F in replacement heavy duty braided PVC connecting pipe with brass adapters 450 mm long suitable for 15 mm dia pipe and fixing in position all as approved by Engineer-in-charge.Make :Havells/Prayg.
193S&F in replacement heavy duty braided PVC connecting pipe with brass adapters 600 mm long suitable for 15 mm dia pipe and fixing in position all as approved by Engineer-in-charge. Make :Havells/Prayg.
194S&F in replacement of top cover made of M S sheet 18 SWG duly painted with two coats of super enamel paint by spray painting suitable for25 ltrsgeysers. complete, all as specified and as directed by Engr-in-Charge .
195All as per serial items No 134 here in before but50litres geysers.
196S&F in replacementsuitable fastner not less than 100 mm for geyserincluding making good to disturbed surface of wall and maching existing surface and finishingcomplete all as specified and as directedin Engr – in- Charge.
197S&F in replacement of split inspection bottom cover made of M S sheet 20 SWG duly painted with two coats of super enamel paint by spray painting complete all as specified and as directedin Engr – in- Chargesuitable for 25 ltrsgeysers.
198All as per serial items No 137here in before but50litres geysers.
199S&Fin replacement of 15 mm bore chromium platedbib taps cast copper alloy with clutch or butterfly handle ,screwed down screwed for iron pipe or for brass ferrule 15 mm boreand fixed complete all as specified and as directed by Engineer in charege.
200S&Fin replacement of 15mm bore brass CP mixture for mixing hot and cold water screwed down for iron pipe 15 mm boreand fixed complete all as specified and as directed by Engineer -in -charge
201S&F pillar taps 15 mm bore cast copper alloy ,with capstan head cromium plated ,srewed down high pressure with long srewed shanks and fly nuts ,screwed for iron pipe 15mm bore and ferrule complete all as specified and as directed
202S&F in replacement of indicating lamp Red or Green as per Geyser suitability complete all as specified and as directed by Engr In Charge
203Supply and fix in replacement of outer body made/fabricated of 22 gauge MS sheet for Geysers of 25 Liters capacity duly painted with spray paint with white clamps 2 Nos of size 15mmx1mm thick with necessary nut and bolts complete all as specified and as directed by Engr-in-Charge.
204All as per serial items No 143 here in before but50litres geysers.
205M& L for Painting of geyser of cap 25/50 ltrs complete at site or in store with super synthetic enamel white paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified an as directed by Engineer -in -charge.