| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2x 1.5 +1x1.5 sq.mm FRLS PVC insulated copper conductor single core cable Havells/ Polycab/ Finolex in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 5/6 amps switchwith modular plate of Hager or Legrand 2/4/6/8/10 way |
| 2 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. Mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. DSR 1.12 |
| 3 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 4 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 5 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 6 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 7 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 8 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wir |
| 9 | 2 X 16 sq. mm + 1 X 6 sq. mm earth wire |
| 10 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 11 | 5/6 A switch |
| 12 | 2 way 5/6 A switch |
| 13 | 15/16 A switch |
| 14 | 3 pin 5/6 A socket outlet |
| 15 | 6 pin 15/16 A socket outlet |
| 16 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required1/2/3/4/6/8 Module |
| 17 | Supplying and fixing following way, horizontal /vertical type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 18 | 4 way (4 + 12), Double door |
| 19 | 6 way (4 + 18), Double door |
| 20 | 8 way (4 + 24), Double door |
| 21 | MCB SP 6-32 A |
| 22 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \"C\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. |
| 23 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required. |
| 24 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 25 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. All size cables |
| 26 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1100 KV grade as required all sizes of Cables |
| 27 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required Length of pole 6- 9 Mtr |
| 28 | Supplying and erection of galvanised \"D\" iron clamps completewith shackle insulator (75 mm X 90 mm),G. I. bolts, nuts and washers, coach screws etc. as required. |
| 29 | Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. As required |
| 30 | Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. |
| 31 | Supplying of channel iron 100 mm X 50 mm X 6 mm (9.56 kg per metre) cross arm for two wire 33 KV over head line conductors complete with 50 mm X 50 mm X 6 mm angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins/ fittings, bolts, nuts, washers etc and painting with primer and finish paint as required . |
| 32 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required |
| 33 | 50 mm dia |
| 34 | 80 mm dia |
| 35 | 100 mm dia |
| 36 | 150 mm dia |
| 37 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63- 120 mm size |
| 38 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required |
| 39 | 1 x 1.5 sq. Mm |
| 40 | 2 x 1.5 sq. Mm |
| 41 | 2 x 2.5 sq. Mm |
| 42 | 2 x 4 sq. mm |
| 43 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 44 | 20 mm |
| 45 | 25 mm |
| 46 | 32 mm |
| 47 | 40 mm |
| 48 | P/f of 7/16 PVC copper wire Grandly/Imperial/Havells/Polycab/ /Alba |
| 49 | P/f of PVC Al cable un armored 1 core 16MM/Havells/Gloster/Impact |
| 50 | P/f of PVC Al cable un armored 1 core 25MM/Havells/Gloster /Impact |
| 51 | P/f of PVC Al cable un armored 1 core 35MM/Havells/Gloster/Impact |
| 52 | P/f of PVC Al cable un armored 1 core 50MM/Havells/Gloster/Impact |
| 53 | P/f of PVC Al cable un armored 1 core 70MM/Havells/Gloster/Impact |
| 54 | P/f of PVC Al cable un armored 1 core 95MM/Havells/Gloster/Impact |
| 55 | P/f of 3 ½core armoured cable Aluminium XLPE 25 Sq MM Grandly/ Havells/ Polycab//Alba |
| 56 | P/f of 3 ½core armoured cable Aluminium XLPE 35 Sq MM Grandly/ Imperial/ Havells/ Polycab//Alba |
| 57 | P/f of 3 ½core armoured cable Aluminium XLPE 50 Sq MM Grandly/ Imperial/ Havells/ Polycab//Alba |
| 58 | P/f of 3 ½core armoured cable Aluminium XLPE 70 Sq MM Grandly/ Havells/ Polycab//Alba |
| 59 | P/f of 3 ½core armoured cable Aluminium XLPE 95 Sq MM Grandly/Havells/ Polycab//Alba |
| 60 | P/f of 3 ½core armoured cable Aluminium XLPE 120 Sq MM Grandly/Havells/ Polycab//Alba |
| 61 | P/f of 3 ½core armoured cable Aluminium XLPE 150 Sq MM Grandly/Havells/ Polycab//Alba |
| 62 | P/f of 3 ½core armoured cable Aluminium XLPE 185 Sq MM Grandly / Havells/ Polycab`/Alba |
| 63 | P/f of 3 ½core armoured cable Aluminium XLPE 300 Sq MM Grandly / Havells/ Polycab//Alba |
| 64 | P/f of PVC Channel 1” including all accessories/bends/sockets//Alba Tee (Flair Make) |
| 65 | P/f of electronic call bell with 1.5 V battery () with bell push and remote etc |
| 66 | P/f of geyser Venus /Racold make 25 Ltr |
| 67 | P/f of geyser Venus /Racold make 35 Ltr |
| 68 | P/f of geyser Venus /Racold make 50 Ltr |
| 69 | P/f of geyser element Venus /Racold 2KW |
| 70 | P/f of geyser element Venus /Racold 2KW |
| 71 | P/f of geyser thermostat Venus 50ltrs capacity |
| 72 | P/f of MCB DP Legrand/Scnidermake 32/40/63 A |
| 73 | P/f of MCB DP Legrand/Schneider/Hager make 100 A |
| 74 | P/f of 4 feet long LED tube light fitting18-20 watt Philips /CG/Havells Slim type |
| 75 | P/f of 2 feet long LED tube lightfitting complete Philips /CG Slim type/Havells |
| 76 | P/f of fan dimmer switch type/socket type legrand make 1 /2 module |
| 77 | P/f of exhaust fan louver type 225 MM Usha/Havells/Crompton |
| 78 | P/f of Industrial exhaust fan 300 mm Make CG / havells /Usha |
| 79 | P/f of 48” sweep ceiling fan with hooks etc Usha/Havells/Crompton 5 star |
| 80 | P/f of Aluminium conductor 0.05 ACSR |
| 81 | P/f of Aluminium conductor 0.03 ACSR |
| 82 | P/f of TPN MCB Legrand /Schneider make with required terminations nuts bolts washers etc 32-63 Amp |
| 83 | P/f of TPN MCCB Legrand/Schneider /Hager make with required terminations nuts bolts washers etc 100 Amp36-40 KA |
| 84 | P/f of TPN MCCB Legrand/Schneider /Hager make with required terminations nuts bolts washers etc 200 Amp 40 KA |
| 85 | P/f of TPN MCCB Legrand/Schneider /Hager make with required terminations nuts bolts washers etc 250 Amp 50-70 KA |
| 86 | P/f of TPN MCCB Legrand/Schneider /Hager make with required terminations nuts bolts washers etc 400 Amp 70 KA |
| 87 | P/f of TPN MCCB Legrand/Schneider/Hagermake with required terminations nuts bolts washers etc 630 Amp 70 KA |
| 88 | P/f of LED flood light fitting with all accessories like 50 W tube. Complete light in all respects Make Havells / /Philips |
| 89 | P/f of LED street light 100 Watt with arm fabrication job .Complete Make Havells //Philips |
| 90 | P/f of LED high mastlight 200 Watt .Complete Make Havells //Philips/L&T |
| 91 | P/f of LED recessed/surface light 7-15 Watt. Complete Make Havells //Philips |
| 92 | P/f of LED lamp 10 watt retrofitMake Make Havells //Philips/GM |
| 93 | P/f of enclosure metallic type Legrand/Schneider / 8 way Double door Acrylic |
| 94 | P/f of enclosure metallic type Legrand/Schneider / 12 way Double door Acrylic |
| 95 | P/f of enclosure metallic type Legrand/Schneider / 16 way Double door Acrylic |
| 96 | P/f of chemical earthing copper bonded 3 M long copper bondedfullycopper electrode with earthing compound etc. Complete earthing job as per IEE standards IS 3043 of 87 |
| 97 | P/f of 32/63 Amp SPN Changeover SSK |
| 98 | P/f of 32 Amp TPN Changeover SSK |
| 99 | P/f of copper strip 12mmx6mmfor earthing |
| 100 | P/f of DC battery 1.5V |
| 101 | P/f of 63 Amp TPN Changeover SSK |
| 102 | P/f of 100 Amp TPN Changeover SSK |
| 103 | P/f of telephone wire 1 Pair |
| 104 | P/f of telephone wire 2 Pair |
| 105 | P/f of telephone wire 5 Pair |
| 106 | P/f of telephone wire 10 Pair |
| 107 | P/f of PVC pipe 2” dia Prince B type |
| 108 | P/f of PVC pipe 3” dia Prince B type |
| 109 | P/f of PVC pipe 4” dia Prince B type |
| 110 | P/L of Steel tubular pole Model SP 15 as per IS 2713 ,8 Mtr long with erection and cement bottoming etc |
| 111 | Supply of 5 KVA voltage stabilizer dry typedesigned from 90V input for AC wall mount |
| 112 | Termination with aluminium thimble /lugs of sizes 35/70/120/185, 300 MM etc |
| 113 | Repair of 1.5 Ton, 2 Ton AC’s by way of replacement of control card, service mains etc including service charges excluding filling of gas . |
| 114 | Gas refilling of 1.5/2 Ton AC .Complete job in all respects |
| 115 | Fabrication of panel of any size outdoor/indoor depth 430 MMwith angle iron stand, bus bar 400A/600 and spacing for MCCB powder coated and locking system. Double door Complete job. |
| 116 | Supply installation of link set heavy duty 11KV 3pc set station type 400 Ampwith all accessories |
| 117 | Supply installation of lightening arrestor set station type heavy duty 11kv 3pc set with all accessories |
| 118 | Supply installation of fuse drop out heavy duty 11kv 3pc set with all accessories |
| 119 | P/l of steel tabular poles as per 410 SP 33 dimensions as total weight 165 Kgs with base plate of size 1.5’x1.5’ x 8 mm with GI rod for earthing etc .Complete job in all respects with cement bottoming 3 ½ feet deep .M 20 Mix with color painting etc . Complete job |
| 120 | Providing & fixing of Hot dip galvanized octagonal pole 8 mtr longwith cement bottoming and foundation bolts etc as required. |
| 121 | S/L of 4 Sq MM 2 core Copper CableMake Havells/Polycab/D10/Winson/Alba |
| 122 | S/L of 6 Sq MM 2 core Copper CableMake Havells/Polycab/D10 /Winson//Alba |
| 123 | S/L of 10 Sq MM 2 core Copper CableMake Havells/Polycab/ D10// Winson / Alba |
| 124 | Cat 6 UTP cable Make D Link /Digi Link |
| 125 | LAN I/O socketbox type or flush type make Dlink /Legrand/Digi Link |
| 126 | 2x2feet LED recessed fitting31-40 Watt |
| 127 | Painting of ST poles of any size . |
| 128 | Supply and filling of transformer oil filtrated and fresh oil. |
| 129 | Clearance of HT fault by way of line surveying , jumpering , branch cutting ,un-binding , binding work excluding line material . |
| 130 | Supply of skilled and unskilled worker for minor electric repairs /LV side fault clearance. The job includes labour part only for one day only. |
| 131 | S/I of 5 A / 16 A Top / |
| 132 | S/I of 15/ 5 A SS combined box type/Plain |
| 133 | Wiring for 16/6 A SS Combined points to be wired in 4 Sq mm + 1X4 Sq mm FRLS multi stranded copper wire 1.1 kVas earth wire ofmake Havells/Polcab /Alba /Khaitan/Finolex to be drawn in PVC conduit 25 MM dia 2mm thick Flair/Jindal/Tiger/Hitec /Alba with other accessories like junction boxes ,bends,etcto be laid in the floor/wall etc .Complete heating wiring point etc. Complete wiring points. andColour coding of wire with tags etc in all respects. Including switch with modular plate of Hager 2/4/6/8/10 way and face plate as required at site .the work includes GI box .and other accessories .Colour coding of wire with tags etc in all respects andSocketA Hager makeNote : for loopedcommon circuitry /other points measurementof wiring and accessories shall be made. |
| 134 | Repair of Street light of weightage 70-120 Watt by way of replacment of driver, powercard etc as needed complete work in all respects |
| 135 | Note: Approved Makes |
| 136 | MCCB /MCB(Hager /Legrand / Schnider/L&T) |
| 137 | Copper Wires FRLS(Havells /Polycab / Finolex /R R kables/ L&T) |
| 138 | Aluminium cables (Havells /Polycab/Fonolex/R R Kables / L&T) |
| 139 | Enclosures DB(Hager /Legrand/Schnider/ L&T) |
| 140 | Changeovers(Havells/Legrand/Schnider/ L&T) |
| 141 | Lighting luminaries / LED fittings (Philips/Havells / L&T /C&S |
| 142 | Fans/Exhaust fans (Usha /Havells/CG Make/L&T) |
| 143 | Note:- The quantities are approximate and are for computation purposes onlyaccordingly the Contractor/s have to quote the ratesin percentage above or below overthe BoQ/Estimatedrates .The Rates quoted are inclusive of all carriages of materials (Mechanical/Manual) from source to site workand all extra charges including dewatering if any during the execution of work complete in all respects. |