Repair And Maintenance Of Ac Plant And Summer Appliances Under Ge Nagrota, nagrota-Jammu And Kashmir

Military Engineer Services-MES has published Repair And Maintenance Of Ac Plant And Summer Appliances Under Ge Nagrota. Submission Date for this Tender is 21-07-2022. Air Conditioner Tenders in nagrota Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

32905514
Repair And Maintenance Of Ac Plant And Summer Appliances Under Ge Nagrota
Open Tender
Indian
Jammu And Kashmir
nagrota
21-07-2022

Tender Details

Repair And Maintenance Of Ac Plant And Summer Appliances Under Ge Nagrota

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

BOQ Items

Name of Work : REPAIR AND MAINTENANCE OF AC PLANT AND SUMMER APPLIANCES UNDER GE NAGROTA
Sl. No. Item Description
1NOTE:- 1.GENUINE SPARE PART SHALL BE REPLACED 2.GUARANTEE CERTIFICATE SHALL BE REQUIRED FROM AUTHORISED DEALER IN THEIR RESPECTIVE LETTER HEAD. 3.DIGITAL PRROF SHALL BE MAINTAINED AT THE TIME OF REPLACEMENT OF ANY SPARE PARTS AND WILL PRODUCED AT TIME OF PAYMENT. 4.DATA REGISTER SHALL BE MAINTAINED OF EVERY NEW INSTALLED SPARE PARTS WITH THEIR GUARANTEE CARD DULY VERIFIED BY GE.
2M&L forcleaning of shell and tube water cooled condensersof the A/C plants of followingcapacities afterdismantling the water lines and headers and cleaning with suitable wire brush and washing soda to remove the dirt andwater scaling and refixing the water lines and headers including provision of new gaskets, in every 04 moths etc complete all as directed byEngr-in-Charge. (a)52 TR capacity at Signal Center
3(b) 52 TR capacity at OPS Room
4(c)15 TR capacity at 4 ASD
5Supply and charging compressor oil Servo manufacturedby Indian Oil Corporation or Equivalventapproved make including flushing/cleaning of oil chamber etc complete all asdirected by Engr-in-Charge.
6Nitrogen testingfor the ANY capacity of compressorsincluding condensing unit and gas piping completeas per the manufacturer instructiions and entire satisfaction of the Engineer in Charge. Note :- (i)Nitrozen pressure should be held with out any dropin pressure inside the unit continue for 24 hrs after leakage testiing reqired gas will be fill andsatisfaction of the Engineer in Charge.
7Supply and fillingNitrogen Gas Cyllinder of 61 Kg Each cyllinder complete
8Supply and fillingRefrigerant gas R-407 of 61 Kg Each Cyllinder for AC plant compressor
9Supply and fillingRefrigerant gas R-22 of 61 Kg Each Cyllinder for AC plant compressor
10M&L for servicing monoblock pumps including dismantling and openingthe pump, repair/replacement of defective Ball Bearing,Roller Bearing .impeller,replace the worn out bearing impeller,stuffing box, back plates, gland packing mechincal seal and rusted nut, bolts etcassembling property , greasing all movable parts, fixing in position, testing and commissioning all as directed for uo To 5HP pumps.
11Same as Ser No 9 but upto 7.5 to 10 HP
12Same as Ser No 9 but upto 10 to 15 HP
13Supply and fixing in repair power assembly expansion valve for up 52 TR AC palntat EHU / ERS Model SVE 42 Make –SPORLAN or equivalent as per the existing.
14Supply and fixing in repair MVPD for up to 52 TR TR capacity at OldAC plant Modelequivalent as per the existing.
15Suuply and fix ofV-beltsize C 2650/ C-102 including taking down old belt .
16All as per item No-14 as above but of size B-112 .
17All as per item No-14 as above but of size B- 82.
18Realignment of compressor and motor of anycapacity on existing foundation.
19Supply and fixing of CI butterfly valves with matching flanges,gaskets,hardware duly insulated with preformed pipe section fabricated to shape and bonded with adhesive. removable cover is required valves in 26swg aluminium sheet,cover should be divided in to portions quick release toggles shall be used for assembly of covers. (a) 50 mm bore.
20(b) 65mm bore.
21Supply and fixHigh pressure control switch type MP-5 including taking down old switch. AS per existing make
22Supply and fixoil pressure control switch type MP-55 including taking down old switch. AS per existing make
23Supply and fixlow pressure control switch type MP-01 including taking down old switch.AS per existing make
24Supply and fixLP/HP cut out type MP-15 inlcuding taking down old cutout.AS per existing make
25All as per item No - 23 but type ML-4Make –AS per existing make
26All as per item No - 23but type ML-3Make – AS per existing make
27All as per item No - 23but type ML-2Make –AS per existing make
28All as per item No - 23but type ML-1.5 Make –AS per existing make
29Supply and fixing power contract assemblycomplete MNX-25 as per cat No CS 94110 Make – L & T or equivalent makeincluding taking down old contactor
30Supply and fixing power contract assemblycomplete MNX-12with one NO and NCas per Exixting Make – L & T or equivalent make aas Schneiderincluding taking down old contactor
31Supply and fixing power contract assemblycomplete MNX 32 Make – AS per existing make including taking down old contactor
32Supply andfixing spare Kit wihtout coil type MU-1 including taking down old kit. Make – AS per existing make
33All as per item No - 31buttype ML-1.5 as per cat No SS91851 . Make – AS per existing make
34All as per item No - 31but type ML-2 as per AS per existing make .
35All as per item No - 31type ML-3 as perexisting make
36All as per item No - 31but type ML-4 as per existing make
37Supply andfixing Overvload relay range 9-15 amps . Make –AS per existing make suitable for ML-1/ML-1.5 contactor
38Supply andfixing Overvload relay range 20-33 amps . Make –AS per existing make suitable for ML-2/ML-3 contactor
39Supply andfixing Overvload relay range upto 7.5 amps. Make –AS per existing make suitable for MNX contactor
40Supply and fixing electronic timer ST 100 (3 to 10 Sec) 240V or as per existing .Make –AS per existing make including taking down of old one.
41Supply and fixing electronic timer ST 100 ST 100 (3 to 30 Sec) 415 Volts AC 50 HZ . Make- L Make –AS per existing makeas GIC suitable to the existing panel board inlcuding taking down of old one.
42Supply and fixing indicator lamp assembly complete LED type suitable for the existing system supply voltage for the existing system supply voltage 230V / 440 V AC including taking down old lamp assembly Make – Mimic control/AEC/C&S.
43Supply and fixing in repair of MCCB3 pole415 volts AC , 250 Amps breaking capcity 25 KA, Make –L &T , or equivalent
44Supply and fixing in repair of MCCB3 pole415 volts AC , 40 Amps breaking capcity 25 KA, Make –L &T , or equivalent
45Supply and fixing in repair of MCCB3 pole415 volts AC , 32 Amps breaking capcity 25 KA, Make –L &T , or equivalent
46Dismantling the unserviceable electric motor any type or of any capacity and transporting to reputed workshop, taking out old and burnt winding wire and rewinding with super enameled copper winding wire of existing gauge andsize with insulating materials, varnishing andbaking etc,re-fixing the same at site andre-alignment,testing and commissioning complete all as directed by Engr-in-Charge
47Taking out old and unserviceable PVC fins of cooling tower of anycapacity AC plant and replacing with new one includingsetting complete .Make:Mihir or equivalent
48Supply and fix in repair in repair DOL starter suitable for 5HP motor capacity 9 to 14 Ampcomplete with over load relay , single phasing preventer under volt release etc .Make L&T or equivalent in Schneider / Havells.
49Supply and fix in repair in repair DOL starter suitable for 10 HP motor capacity 14 to 23 Ampcomplete with over load relay , single phasing preventer under volt release etc .Make L&Tor equivalent make as Schneider / Havells.
50Preparation of old painted surfaces by removing dust,rust etc and, applying two coats of synthetic enamel paint with spray gun of approved make and colour for cooling tower,condensing pipe line condenser water pumps including all pipe line valves etc. of 5 TR to 60 TR Capacity Plant.
51Supply and fix CT fan (with hub and fan blade) of capasity 5 to10 HPfor colling tower all as specified and directed by Engr-in-Charge
52S & F in repair chilled water sensor for AC Plants ofup to 52 TR capacity
53S & F solenoid valve assembly complete for compressor of capacity upto 15 TR.
54S & F solenoid valve assembly complete for compressor of capacity fromupto 52 TR.
55S & F loading/unloading switch assembly for compressor of capacity upto 15 TR.
56S & F loading/unloading switch assembly for compressor of capacity fromupto 52 TR.
57S & F microprocessor for compressor of capacity upto 15 TRof existing model
58S & F microprocessor for compressor of capacity from 52 TRof existing model
59S & F cooling tower nozzles 1/4"" size of existing model
60S & F block bearing for air handling unit existing sizeof existing model
61Dismantling the compresor and taking out the shaft from the compressing unit and taking to the reputed workshop for necessary lathe/ machining work to match the bearing size, cleaning inside the compresing unit and necessary overhauling complete as directed .Installation of compressor and connect with motor , alingmentand carrying out of testing to the entire satisfaction of Engr-in-charge for the following compressor model :-Note : defective Spares required to be replaced shall be measured and paid seperately under appropriatre items of this schedule. (a)3 X 7.5 TR capacity at 4ASD
62Supply in replacement for 3 X 7.5 TR capacity at 4ASD (a) Main bearing ( U/S upto 0.5 mm) for both ends
63(b) Connecting rod bearing
64(c) C R bush
65(d) pistons
66(e) Pistons pin
67(f) Piston ring set
68(g) Piston circlips
69(h) C R Nuts & bolts
70(j)S V Reeds
71(k) D V Reeds
72(l)S VSprings
73(m) D V Spring
74(n) Suction filter drayer.
75(o Oil pump
76(p) Linear o ring
77(q) Gasket set
78(r )Thurst washer
79(s) Aluminium Gasket set
80(t) Rocker arm with cup & washer
81(u) Oil pressure regulating valve
82(v) Rocker arm spring
83(w) Suction and discharge valve O ring set
84S & F in repair water Flow Gauge Meter for AC Plants ofany capacity
85S & F in repair Oil Pressure Gauge Meter for AC Plants ofany capacity
86S & F in repairRefrigerant Gas Pressure Gauge Meter for AC Plants ofany capacity
87Supply and fixing in repairof 13 TRsemisealed/sealed compressor with modification to existing system including testing complete all as specified and directed by Engr-in Charge.Make Kirloskar, Brite,
88Repair and maintenance of Ac plant heater incliding internal wiring and replace of any part of internal body all as specified and as directed by Engr-in-charge.
89Material andLabour for servicing of following appliances comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for the following capacity of water cooler / refrigerator :- (a) Water coolers 40 to 150 ltrs cooling capacity.
90(b) Refrigerator of 165 to 310 ltrs capacity.
91(c) Deep Freezers any capacity
92Supply and replace compressor sealed unit of the following appliances of any make complete including replacement of copper tubing/capillary strainer etc, testing and commissioning all as specified and as directed by Engr-in-Charge. (a)Water coolers of capacity up to 150liters.
93(b) Refrigerators of capacity 210 to 310 ltrs.
94(c) Deep freezers 200 to 300 ltrs capacity.
95Supply and replace starting relay suitable for :- (a) Water coolers 40 to 150 ltrs cooling capacity
96(b) Refrigerator of 165 to 310 liters capacity.
97(c) Deep freezers of 200 to 425 ltrs capacity.
98Supply and replace thermostats of :- (a) Water coolers 40 to 150 ltrs cooling capacity.
99(b) Refrigerator of 165 to 310 ltrs capacity.
100(c)Deep freezers of 200 to 325 ltrs capacity.
101Supply andcharging refrigerant gas R-22/R-134 (A)up to required level incl connected works like pressure testing with nitrogen before filling refrigerant gas including leakage testing if any complete all as specified and directed by Engr-in-Charge (a) Water cooler 40 ltr cooling cap.
102(b) Water cooler 80 ltr cooling cap.
103(c) Water cooler 150 ltrs cooling cap
104(d) Deep freezers ofany capacity.
105(e) Refrigerators of any capacity.
106Supply and replace condenser unit of the following appliances including making of all connections as specified and directed by Engr-in-Charge. (a) Water coolers 40/60 ltrs capacity.
107(b) Refrigerator of 165 to 195 ltrs capacity.
108(c) Deep freezers of 200 to 300 ltrs capacity.
109Supply and replace top cover gasket of water cooler 40 to 150 ltrs capacity.
110Supply and replace overload protector of : (a) Water coolers/ Refrigarator upto 150 ltrs cooling capacity
111(b) Deep freezers of upto 425 ltrs capacity.
112Supply and replace blower/condenser fan motor complete with necessary mounting bracket to and base frames for :- (a) Water coolers of any make and cap 40 to 150 ltrs capacity.
113(b) Deep freezers of any make & cap 200 to 300 ltrs capacity.
114Supply andcharging refrigerant gas R-22/R-134 (A)up to required level incl connected works like pressure testing with nitrogen before filling refrigerant gas complete all as specified and directed by Engr-in-Charge. Make Paragon,Mefron(Note : Above secondfloor contractor willarrange crain / scaffolding with safety device) (a) Window type room air conditioners of capacity 1.5 Ton.
115(b) Split type AC 1.5/2.0 Ton capacity
116M&L for servicing of following appliances comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for :-(Note : Above secondfloor contractor willarrange crain / scaffolding with safety device) (a) Window type room air conditioners of capacity 1.5 Ton cap.
117(b) Split type AC 1.5/2 Ton capacity.
118Supply and replace compressor sealed unit of the following appliances of any make complete including replacement of copper tubing/capillary strainer etc, testing and commissioning all as specified and as directed by Engr-in-Charge. (a) Window type air conditioners of capacity 1.5 /1 Ton.
119(b) Split type AC 1.5/2.0 Ton capacity.
120Supply and replace capacitors of the following capacities for ACs Make :Siemens,epcos (a) 3.15 ,4 & 6 Mfd
121(b) 10 Mfd
122( c) 36 Mfd
123(d) 80/100 Mfd
124(e) 120 Mfd
125(f) 45+6 Mfd Seven Pin
126Supply and replace starting relay suitable for :- (a) Window type room air conditioners of capacity 1/1.5 Ton cap.
127(b) Split type AC 1.5/2 Ton capacity
128Supply and replace thermostats of :- Make Danfoss,Annapooma (a) Window type room air conditioners of capacity 1/1.5 Ton cap.
129(b) Split type AC 1.5/2 Ton capacity.
130Supply and replace oeverload protector of :- Make Usha,Annapooma (a) Window type room air conditioners of capacity 1/1.5 Ton cap.
131(b) Split type AC 1.5/2 Ton capacity.
132Supply and replace condenser unit make of copperof the following appliances including making of all connections as specified and directed by Engr-in-Charge (a) Window type room air conditioners of capacity 1/1.5 Ton capacity.
133(b) Split type AC 1.5/2 Ton capacity.
134Supply and replace metal clad/sheet metal plug and socket with a 2 pin and earth plug and 20 Amps SP MCB complete including making all connections. complete all as directed by Engr-in-Charge.
135Supply and replace contact unit of split type air conditioning of 1.5/2 Ton capcomplete all as directed by Engr-in-Charge.
136M & L voltage stabilizers AC single phase. 2 to 5 KVA of any make by opening of the body, cleaning of internally, checking and tigtening of all terminal connections including replacement of worn out terminal connectors, screws, bolts complete all as directed by Engr-in-Charge.
137Supply And Fix with repairof defective burnt motor from unitand testingall as directed for the following;- (a) Window type AC of any make capacity 1/1.5 Ton cap.
138(c) Split type AC of any make and capacity 1.5/2 ton.
139Supply and fix insulation for copper tubes of split type AC units,insulation type superion of sizen 3/8"diameter
140Supply and fix insulation for copper tubes of split type AC units,insulation type superion of sizen 5/8"diameter
141Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 5/8" diameter
142Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 3/8" diameter
143Supply and fix PCBcercuit board complte suitable for 1.5/2.0 ton capacitysplit type air conditioneer complete all as directed by Engr-in-Charge.
144Supply and fix PCBcercuit board complte suitable for 1.5/2.0 ton capacityWindow type AC complete all as directed by Engr-in-Charge.
145Supply and fix in repair Remote of any size and capacity of split AC . complete all as directed by Engr-in-Charge.
146Supply in replacement of indoor collingunit 1.5 Toncapacity copper tubing with rotary fan suitableof existing make with suitable remote complete all as directed by Engr-in-Charge.
147S&Fin replacement of desert cooler 1350 Rpm capacitymotorcopper wounded with fan blade with all arrangement complete all as directed. Make Khetan/Havells/Crompton
148Replacement of water circulation submersible pump of minimum head 5 feet of desert cooler suitable for operation on AC supply single phase 230/250 volts 50 Hz.Complete all as directed by Enngr-in-Charge.Make : Khetan/Havells/Crompton
149Taking out existing old wood wool pads from desert coolers and S&Fwood wool padswith nylon threads suitable for any make of desert cooler having minimum/maximum capacity 3000 cum/hr and 5000 cum hrs including S&F PVC insulated protective guards for holding the wood pads complete all as specified and as directed.
150S&F body in replacementof galvanized iron sheets with bottom tank of 22gauge ofdesert cooler, top cover of 24 gauge and side panels of 22 gauge GI sheet duly fitted with 2” thick wood wool pads including on heavy duty 22 guage frontgrill fitted with one piano type 5 Amps switch three speed selector switch of approved make with arrangement of changing the direction of air flow complete all as directed.
151Replacement of PVC water distribution system 4 way suitable for 3000/4000 Cum/Hrs of desert coolers complete with PVC Elbow, PVC Pipe (distribution system to side panel with elbow at end )heavy duty 15mm dia all as directed.
152Replacement of three speed selector switch complete with knob of approved make for desert cooler complete all as directed by Engr-in-Charge.
153Replacement of unserviceable side panels with wood wool 2" thick for desert cooler made out of 22 gauge plane GI sheet of existing size of desert cooler complete. (EachSet Of Three Panels) complete all as directed by Engr-in-Charge.
154Replacement of damaged/rusted front grill made out GI sheet of 20 gauge heavy duty complete with knob to separate the shutter and S&F one piano type switch 6 Ampand one three speed selector switch complete all as specified and as directed by Engr-in-Charge.
155Painting of desert coolers in side out side at site of work with two coats of synthetic enamel paint grey or any other shade (as approved) from out side complete including shutters top, bottom with spray painting machine and in side with black anti – corrosive paint (two coats) complete all as specified and directed.
156Taking down oldsplit/ window type Air Conditioner of any capacity and reinstalled at new location after completing serviceing including Making good disturbed surfaces by means of using sand, cement etc. complete all as specified & directed
157Sub main wiring with two single core FRLSPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sq mm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked 25 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4.0 sq mmas earth continuity conductorconnected to commen earth and earth dolly complete.Note :02 Run of 06 sqmm single core copper conductor , 01 No 04 Sqmm size copper conductor & 01 run of PVC rigid conduit of 25mm dia shall be considered 01 unit for payment purpose.
158Replacement of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one SPN MCB 240 volts 40 amps .Make:Havell"s/ABB/Legrand
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail