Provision Of Three Phase Power Supply For Winch Testing Facility At Assp Building And Pressure Testing Facility At Npol, Kochi, kakkanad-Kerala

Military Engineer Services-MES has published Provision Of Three Phase Power Supply For Winch Testing Facility At Assp Building And Pressure Testing Facility At Npol, Kochi. Submission Date for this Tender is 19-07-2022. Electrical Maintenance Tenders in kakkanad Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

32898591
Corrigendum : Provision Of Three Phase Power Supply For Winch Testing Facility At Assp Building And Pressure Testing Facility At Npol, Kochi
Open Tender
Indian
Kerala
kakkanad
19-07-2022

Tender Details

Provision Of Three Phase Power Supply For Winch Testing Facility At Assp Building And Pressure Testing Facility At Npol, Kochi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Jul-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-07-2022
2 08-Jul-2022 date corrigendum Date 19-07-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 38600.0 /-
Tender Value
INR 19.30 Lakhs /-

BOQ Items

Name of Work: PROVISION OF THREE PHASE POWER SUPPLY FOR WINCH TESTING FACILITY AT ASSP BUILDING AND PRESSURE TESTING FACILITY AT NPOL, KOCHI
Sl. No. Item Description
1Supply, install, test and commissioning of outdoor type double door LT Feeder pillar box made out of 3.0 mm thick CRCA sheet outdoor type totally enclosed weather dust and vermin proof as per IS , CPRI Approved with front opening suitable locking arrangement having copper bus bar of 375 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary PCC 1:3:6 in foundation and made out of 50 mm x 50 mm x 6 mm angle iron grouted at ground above 30 cm from ground level comprising of the following complete all as specified and directed by Engineer-in-Charge. Note: Cost of necessary internal wiring from bus bar to MCCBs/MCBs/Enclosure connections etc shall be deemed to be included in the unit rate. (LT Panel No- 01 at Work Shop).
2Incoming:
3(a)MCCB 250 Amp 4 pole 36 KA Ics=100% of Icu with spreader & rom-01 No. (b) Indicating Lamp Red/Yellow/Blue - 03 Nos (c) SP MCB 6A -03 Nos (d) MFM Metr with CT- 01 No
4Outgoings.
5(a) 160 Amp 4P MCCB 25 KA Ics=100% of Icu with spreader & rom -02 Nos. (b)63 A 4P MCCB 25 KA Ics=100% of Icu with spreader & rom -01 No. (c) 16 Amp 4 MCCB 16 KA, Ics=100% of Icu with spreader & rom -01 No.
6supply ,install ,test and commissioning of Outdoor type double door LT Feeder pillar box .made out of 3.0 mm thick CRCA sheet Outdoor type totally enclosed weather dust and vermin proof as per IS , CPRI Approved with frontand rear opening suitable locking arrangement having Copper bus bar of 600 Amps capacity for RYB and half for neutral and insulated with insulators, including cnnecting and outgoing cables necessary PCC 1:3:6 in foundation and made out of 50 mm x 50 mm x 6 mm angle iron grouted at ground above 30 cm from ground level with comprising of the followings. Note: Cost including necessary internal wiring to CT "s and Meters. (LT panel No 02 at ASSP bldg).
7Incoming:
8(a)MCCB 400 Amp,TPN, 36 KA, Ics =100% of Icu with Spreader & rom-01 No (b) Indicating Lamp Red/Yellow/Blue - 03 Nos (c) SP MCB 6A -03 Nos (d) MFM Metr with CT- 01 No
9Outgoings:
10(a) MCCB 160 Amp, 4 Pole, 25 KA , Ics-100% of Icu with spreader & rom -03 No (b) MCCB 125 Amp, 4 Pole, 25 KA , Ics-100%of Icu with spreader & rom -01 No (c) 32 Amp 4 MCCB 16 KA, Ics=100% of Icu with spreader & rom -01 No.
11M&L for extending the existing LT panel board at LT substation above Central AC Plant of Main Lab with 2.0 mm thick CRCA sheet Factory made Indoor type totally enclosed weather dust and vermin proof as per IS , CPRI Approved, with front and rear opening suitable locking arrangement with necessary copper bus bar of capacity 480 Amps with necessary supporting insulators so as to match with the existing LT panel board/ Distribution panel by connecting to existing bus bar by using rigid copper bus bar by opening the one side of existing panel /bus bar including necessary supporting frame /channel fix through existing cable trench from ground with comprising of the followings:-
12(a)MCCB 320 Amp , 4Pole, 36KA, Ics-100% of Icu with spreader and rom-01 No (b)Provision for outgoing cable of size up to 150 sq mm from the extended portion of LT distribution panel
13M&L for extending the existing LT panel board at T complex LT substation with 2.0 mm thick CRCA sheet Factory made In door type totally enclosed weather dust and vermin proof as per IS , CPRI Approved, with front and rear opening suitable locking arrangement with necessary copper bus bar of capacity 750 Amps with necessary supporting insulators so as to match with the existing LT panle board/Distribution panel by connecting to existing bus bar by using rigid copper bus bar by opening the one side of existing panel /bus bar including necessary supporting frame /channel fix through existing cable trench from ground with comprising of the followings:-
14(a) MCCB 500 Amps, 4 Pole, 36 kA, Ics =100% of Icu with spreader and rom-1 No.
15(b)Provision for outgoing cable of size up to 300 sq mm from the extended portion of LT distribution panel
16Note for SI Item No 01, 02, 03 and 04 :(i) Contractor has to submit the drawing for LT panel board before commencement of work and get it approved from Accepting Officer
17ii) Contractor has to take the shutdown from the MRS 11KV Substation at technical area with prior permission for extending of main LT panel at sub stations
18ii) Contractor shall be cleaned the existing LT panel before making connections from existing LT panel to new LT panel after shut down
19S&F Industrial surface/wall mounting socket 125 Amp 4 pole with straight plug 125 Amp 4 Pole + E400 V IP 67 protection and sockets enclosure as PLEXO3 cabinet IP 65 protection 8 MOD fixed on wall withincluding incoming MCB TPN 125 Amp FP all as specified and as directed Make: MDS Legrand /L&T/Siemens.
20M&L for XLPE insulated, armoured , heavy duty electric cable with aluminium conductor , 1100 Volts grade , in trenches/fixed on wall of following cross-sectional area Note (i) Rate include the cost of lug of proper size and cable gland (ii) Necessary Excavation, PCC cover and sand cushioning shall be measured &paid separately
21(a)Cable of size 150 sq mm 3.5 core
22(b)Cable of size 70 sq mm 3.5 core
23(c)Cable of size 35 sq mm 3.5 core
24Excavation in trenches not exceeding 1.5 m deep and 1.5 m width as in soft/loose soil complete all as specified
25Returning filling incl leveling watering and well ramming in layer not exceeding 25cm thick complete all as specified& directed by Engineer-in-Charge.
26Removal of surface soil to a distance n.exc 50m and deposited where directed at a level n.exc1.5 m above the starting point complete all as directed.
27S & L for Sand for cushioning for cable protection in trenches 8 cm before laying cable and 15 cm deep over the cable (Note:Punned thickness shall be taken for measurement )
28Supply and lay unreinforced precast cement concrete cable cover for protection of underground cable in trenches class LV flat size 250 x 150 x 40 mm.
29M&L Earthing complete with GI earth plate electrode 600mm x 600mm x 6.0mmthickburied directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of 25x 4mm by means of bolts, nuts, washers etc., GI earth strip shall be protected by 40mm dia GI pipe "medium grade", watering pipe 20mm dia GI pipe "light grade", GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C1 earth chamber with 40mm x 40mm x 6mm MS angle iron frame, 40mm thick RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 75mm c/c both ways etc., with plastering 15mm thick in CM (1:6) internally and upto 150mm below GL externally, PGI funnel with wire mesh, complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as specified and as directed.
30NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre.
31Supply and lay in trenches /fixed on wall GI tubing light grade with necessary fittings such as bend , tee, elbow etc complete for the following sizes
3280 mm bore
3350 mm bore
34M&L for PCC 1:4:8 type D2 (using 40 mm graded aggregate) as in mass concrete, filling , etc. complete all as specified and directed.
35M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in coping including use and waste of form work etc. complete all as specified and directed.
36Material and Labour for cross arms. Bracings, supports, clamps and back plates fabricated from structural steel sections including nuts ,bolts, washers, welding bending cold or hot ,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat , one under aluminium coat and one aluminium finishing coat of paint complete all as specified for supporting frame for fixing the single phase enclosure and as directed by Engineer -in-Charge.