Balance Work Pertaining To Repair/Renovation Of Common Incubation Centre At Narwal, Jammu, Jammu And Kashmir
Tender Overview
Project Description
Balance Work Pertaining To Repair/Renovation Of Common Incubation Centre At Narwal, Jammu, Jammu And Kashmir
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 07-Jul-2022 | Corrigendum | Date | 12-Jul-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Repair/Renovation and construction Work |
| 2 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in |
| 3 | Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 4 | 6MM CEMENT PLASTER |
| 5 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering,finishing and reinforcement. All works upto plinth level |
| 7 | 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | FORM WORKCentering and shuttering including strutting, propping etc. and removal of form for: |
| 9 | Foundations, footings, bases of columns etc. for mass concrete. |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level |
| 11 | Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 12 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Zsections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) |
| 13 | Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15) |
| 14 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings whereverrequired including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) |
| 15 | Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15) |
| 16 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc.complete as per architectural drawings and directions of engineerincharge |
| 17 | Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. |
| 18 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions ofengineeringcharge. (Cost of aluminum snap beading shall be paid in basic item.) |
| 19 | With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm) |
| 20 | Providing and fixing aluminum tubular handle bar 32mm outer dia, 3.0mm thick & 2100mm long with SS screw etc. complete as per direction of Engineer-in-charge. |
| 21 | Anodized (AC 15)aluminum tubular handle bar |
| 22 | Providing and fixing Brass 100mm mortice latch and lock with 6levers without pair of handles (best make of approved quality) for aluminiumdoors including necessary cutting and making good etc. complete. |
| 23 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50meters lead as per direction of Engineer-in-charge: |
| 24 | In cement mortar |
| 25 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointedtogether at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outsidelocking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured |
| 26 | 80x1.20 mm M.S. laths with 1.20 mm thick top cover |
| 27 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: |
| 28 | 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 29 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 30 | Welded |
| 31 | providing and fixing of Single Phase Turbo Force Heavy Duty 900rpm 600mm Exhaust Fan. |
| 32 | Single Phase Turbo Force Heavy Duty 900rpm 600mm Exhaust Fan |
| 33 | Providing and fixing bolts including nuts and washers complete |
| 34 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work |
| 35 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting |
| 36 | VITRIFIED FLOOR TILESProviding and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete |
| 37 | Size of tile 600x600 mm |
| 38 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead. |
| 39 | For thickness of tiles 10 mm to 25 mm |
| 40 | PP-R PIPES AND FITTINGS Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. |
| 41 | PN-16 pipe , 32mm OD(SDR-7.4) |
| 42 | Single Stage 2hp Centrifugal Monoblock Pump |
| 43 | Capsule type 3 layer PUF insulated water tank. (2000 ltr) |
| 44 | Electrical Work |
| 45 | MCC Panel with Automatic power factor controller Panel. |
| 46 | Main distribution Panel should include both Mains & the D.G supply with proper electrical/mechanical interlocking system. The panel should include all the MCCB\"s, Power Contactor\"s, C.T\"s, MCB\"s , Panel indicators, Relays, Earthing points, Metering system E.T.C as per the specificationsPanel shall be free standing, floor mounting, compartmentalized and modular in construction, fabricated out of 14/16 gauge CRCA sheet steel duly pretreated and painted with 2 coats of red-oxide zinc-chromate primer and 2 coats of synthetic enamel paint / powder coated MCC shall have separate incomer section with door interlock and isolated bus-bar chamber. Bakelite/acrylic shrouds with danger lables shall be provided as required to cover live parts and busbars for safety purpose. Separate cable-alleys shall be provided. Cable entry shall be top or bottom as per site conditions. Aluminium anodized labels shall be provided for components and feeders. 32 x 6 mm copper earth busbar shall be provided along panel length. Necessary pedestal / mounting structure, sheet metal blanking covers, foundation bolts and all required material/accessories etc |
| 47 | APFC Panel with adequate capacitors to maintain Power factor = 0.95.including P.F controller, metering, indicators etc., |
| 48 | 40 KVAR Capacitor Bank with 10KVARX3 & 5 KVARX2 |
| 49 | ALUMINIUM CONDUCTOR PVC INSULATED ELECTRIC ARMOURED CABLES: |
| 50 | Providing, laying and fixing of Aluminium conductor, PVC insulated and PVC sheathed, armoured / XLPE power cables, working voltage 1100V grade on surface etc. as per IS : 1554, with necessary dressing, clamping, cleating, tagging etc. incl. termination. |
| 51 | 2R X 3.5C X 185 SQ MM ARMOURED AL,1100V |
| 52 | 3.5C X 50 SQ MM ARMOURED AL, 1100V |
| 53 | 3.5C X 25 SQ MM ARMOURED AL,1100V |
| 54 | COPPER CONDUCTOR PVC INSULATED ELECTRIC ARMOURED CABLES: |
| 55 | Providing, laying and fixing of Copper conductor, PVC insulated and PVC sheathed, armoured / XLPE power cables, working voltage 1100V grade on surface etc. of the required size. as per IS : 1554, with necessary dressing, clamping, cleating, tagging etc. incl. termination. |
| 56 | 4C X 6 SQMM,CU, ARMOURED,1.1KV |
| 57 | Supply and laying of 2 Core, 1.5 Sq. mm twisted pair copper conductor cable, low smoke zero halogen, high performance silicon rubber insulated, overall shielded, sheathed fire survival (HPSR) armored cable on surface/ recess/ existing couduit/ existing cable tray complete in all respect as per BS 6387 CWZ, EN50200, LPCB approved for the same size.(As per actual requirement) |
| 58 | 2C X 2.5 SQMM,CU, RUBBER COATED |
| 59 | 2CX1.5 SQMM,CU, RUBBER COATED |
| 60 | Supply, laying & fixing 14 SWG single compartment GI race way of following sizes along-with necessary cable support system as directed including fixing accessories like dash fasteners cable ties and junction box etc. complete in all respects including earthing of trunking with 4sqmm. PVC insulated wires including cutting chasing of floor and making of good (cutting of floor by machine).GI Race ways shall be minimum 20mm below floor finish as required as per approved drawings, specifications of this tender and directions of Project Manager. (For Heavy cable we use Cable tray & for cable which is use for single phase light we use casing caping). Supplying & installing of perforated pre-painted M.S cable trays with perforation not more than 17.5%, in convinient sections,joined with connectors, suspended from the ceiling with M.S suspenders including bolts & nuts, painting suspenders etc as required. |
| 61 | 300 MM X 50 MM X 2MM |
| 62 | 150 MMX 40 X 2MM |
| 63 | Providing of PVC Conduit of 25mm Grey industrial grade including all necessary hardware |
| 64 | EARTHING, EARTHING PIT\"S, L.A\"S |
| 65 | EARTHING: GI Electrode Earthing with 80 mm dia and3 meter length, should be hot-dipped galvanized with 120-150 micron. The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 50 kg BackFill with eco-friendly CCM and having RoHs certification.GI ElectrodeEarthing should be maintenance free without the need of filling water. GI Electrode Shall be tested from CPRI.The earting pit should be cover with FRP cover, of300 x 300mm.GI Electrode earthing should be as per approved list of makes. (CHEMICAL EARTHING) |
| 66 | G.I EARTHING STRIPS: Supplying and fixing 25mm x 5mm GI strip on surface or in recess for earthing connection etc. as required. |
| 67 | COPPER EARTHING STRIPS: Supplying and fixing 25mm x 5mm copper strip on surface or in recess for earthing connection etc. as required. |
| 68 | Supply , design and installation of electrical items (POLE\"S, L.A & CIRCUIT BREAKERS) |
| 69 | LIGHTENING CONDUCTOR: Providing and fixing of Lightning conductor finial, made of 25mm dia 300mm long GI tube, having single prong at top, with 85mm dia 6mm thick GI base plate including hole etc. complete as required. |
| 70 | Riveting, sweating and soldering of copper / GI tape with another copper / GI tape base of the finial or any other metallic object as required. |
| 71 | POWER DISTRIBUTION BOARD/PANEL & TPN/MCB\"S |
| 72 | DISTRIBUTION BOARD &3 PHASE METER & SUB MAIN DISTRIBUTION BOARD (SMDB): Supplying andfixing following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board double door of sheet steel, dust protected, duly powder painted, inclusive of 80 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s, with provision of 40A / 63A TP 16 KA MCCB as incomer, interconnection between incomer MCCB and bus bars ( with 6 MCB’s/ MCCB) as required.(As per actual required we will change size) |
| 73 | 16 WAY TPN DB DOUBLE DOOR |
| 74 | S/I/T/C 4 way MCB complete with all accessrories as required. |
| 75 | S/I/T/C 2 way MCB complete with all accessrories as required. |
| 76 | S/I/T/C of MCB\"s of Following Sizes |
| 77 | 10A SP |
| 78 | 63A TPN |
| 79 | 40A DP |
| 80 | METERING: |
| 81 | MULTIFUNCTION METER: S/I/T/C 3 Phase Multifunction Meter, L&T, 4410 LED, Class 0.5 with RS 485 along with 3 Nos. CTs of 400/5A Class-I and 3 phase indicator lamps, internal wiring with copper flexible wire, all connections, testing, commissioning and other petty material required to complete the job including labour charges or erection in existing cubical panels with cost of cutting the panel sheet and din bars etc. |
| 82 | BATTERY CHARGER/U.P.S/INVERTER |
| 83 | S/E of230/48Volts 440AH ,Battery charger with rectifier, DC Ammeter, DC Voltmeter and common DC bus for DC supply to battery. |
| 84 | UNCLASSIFIED ITEMS: Providing and fixinng MV danger notice plate of 200mm x 150mm made of mild steel at least 2mm thick and vitreous enameled white on both sides and with inscription in signal red color on front side as required |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender