| 1 | Shifting/ transporting repairable summer appliances such as window & split type air conditioners, refrigeratorsandwater cooler from location to contractor\"s workshop for checking & repair as well as replacement of defective parts, making equipments in serviceable condition including refixing the same in the existing location and 24 hrs testing complete, all as specified of following capacities:- |
| 2 | (a)Window Type AC 1.5 TR. |
| 3 | (b) Split type AC of capacity upto 2 TR. |
| 4 | (c) Refrigerators of capacity upto 165/ 180/ 280/ 285/ 310 litres. |
| 5 | (d) Deep freezer of capacity 300/ 400 Litres. |
| 6 | (e) Water cooler of capacity 100/ 125 Litres. |
| 7 | Maintenance, servicing, overhaulingof any nature of defective various capacity split/ window type AC including cleaning of air filters, checking of wiring and replacing defective spares as required.Note for Serial Item No 1.01 to 1.05 :- (i)Replaced sparesparts shall be measured and paid separately under respective Items of Schedule \"A\" as supply only. (ii) Taking out the entire unit from the window after unscrewing front cover, packing material, ply or any type of front cover. (iii) Servicing/cleaning the entire unit with elect blower and cleaning with collin or equivalent agent. (iv) Testing and refixing complete all as directed. (v) Through care/protection of PCB plate shall be kept to avoid any kind of damage while servicing / cleaning. (vi) Sealing of unit with thermocol/packing material shall be part of the job at no extra cost. (vii) Each service shall be measured and paid seperately as each job.(vii) However small pieces of wire terminals, soldering/ clipings required at site for proper fuctioning of the Equipment is deemed to be included in quoted rates under this item. |
| 8 | All as per item No. 2 above but refrigerator of various capacities. |
| 9 | All as per item No. 2 above but Deep freezer of various capacities. |
| 10 | All as per item No. 2 above but water cooler of capacities 100/ 250 Litres. |
| 11 | Supply only compressors for refrigerators/ AC\"s of following capacities :-Make - Godrej/LG /Whirlpool.(Note:- Cost of labour is included in Serial Item No 1.01 to 1.05 here-in-before). |
| 12 | (a) Refrigerator, Capacity upto 195 litres. |
| 13 | (b) Refrigerator, Capacity upto300 litres. |
| 14 | (c) Window/ split type AC of Capacity 1.5 Tone. Make - Hitachi/LG /Whirlpool.Make - Hitachi/LG /Whirlpool. |
| 15 | (d) Window/ split type AC of Capacity 2 Tone. Make - Hitachi/LG /Whirlpool.Make - Hitachi/LG /Whirlpool. |
| 16 | (e) Deep freezer of capacitiy 400 Litres. Make - LG/Whirlpool/Godrej/Tecimseh. |
| 17 | (f) Water cooler of capacitiy 100/250 Litres. |
| 18 | Taking out old unsv parts and S&F Jointing capillary tubes filter strainer by brazing cleaning/flushing whole the system, checking any leakage and making good including testing at pressure 350 PSI complete for the following capacity :- |
| 19 | (a) Window/spilt type AC upto 2.0 TR capacity |
| 20 | (b) Refrigerator of Capacities 310 litres. |
| 21 | (c) Deep freezer of capacitie 300/ 400 Litres. |
| 22 | Taking out old unsv parts and S&F following materials/ accessories suitable for 1.0/ 1.5/ 2.0 TR capacities window/ split type Air Conditioners :-(Note:- Cost of labour is included in Serial Item No 01.01 to 1.05 here-in-before). |
| 23 | (a)Static & Running capacitor 50.0 mfd (+10/-5%), 440 Volts ACsuitable for 1.5 TR Air Conditioner. |
| 24 | (b) Charging of refrigerant R-134 packing with 450g of each can. |
| 25 | (c) Charging of refrigerant R-600 packing with 450g of each can. |
| 26 | (d) Satic & Running capacitor 60.0 mfd (+10/-5%), 440 Volts ACsuitable for 2.0 TR Air Conditioner. |
| 27 | (e) Filter strainer (copper). |
| 28 | (f) Themostat switch for window AC rotary type |
| 29 | (g) Out door unit Condenser fan blade for split AC of capacity upto 2 TR.(Make as per existing make i.e. Carrier, Usha, Videocon, Samsung, LG, Bluestar Etc). |
| 30 | (h) Outdoor Unit Condensor fan motor for split AC of capacities upto 2 TR.(Make as per existing make i.e. Carrier, Usha, Videocon, Samsung, LG, Bluestar Etc). |
| 31 | (j) Indoor unit blower Fan (As per existing make such as Carrier, Usha, Videocon, Samsung, LG, Bluestar etc). |
| 32 | (k) Indoor unit blower motor. (As per existing make such as Carrier, Usha, Videocon, Samsung, LG, Bluestar etc). |
| 33 | (l) PCB Board for window/ split type AC (Hot & Cold Model).(As per existing make such as Carrier, Usha, Videocon, Samsung, LG, Bluestar, Voltas etc). |
| 34 | (m) Indoor Unit auto Swing motor12 Volt DC. as per existing Make. |
| 35 | (n) Gum Metal Rubber bushing for blower motor. (As per existing make such as Carrier, Usha, Videocon, Samsung, LG, Bluestar etc). |
| 36 | (o) Copper alloy plug as per sample. |
| 37 | (p) Outdoor unit Suction service valve with brass cap. |
| 38 | (q) Outdoor unit Discharge service valve with brass cap. |
| 39 | (r) Running capacitor 2.0 mfd (+10/-5%), 440 Volts AC |
| 40 | (s) Running capacitor 4.0 mfd (+10/-5%), 440 Volts AC |
| 41 | (t) Running capacitor 6.0 mfd (+10/-5%), 440 Volts AC |
| 42 | (u) Indoor unit complete for spilt AC 2.0 TR (hot & Coldmodel) as per existing Make orLG /Bluestar/Voltas. |
| 43 | (v) Outdoor unit complete for spilt AC 2.0 TR (hot & Coldmodel)as per existing Make LG /Bluestar/Voltas. |
| 44 | (w) PVC Pipe 1/2\" for water drain |
| 45 | (x) PVC lock for insulation of cu tube |
| 46 | (y) Solonid Valve |
| 47 | (z) Pluring nut & Copper tubing 1/2\" |
| 48 | (aa)Pluring nut & Copper tubing 1/4\" |
| 49 | (ab)Pluring nut & Copper tubing 5/8\" |
| 50 | (ac)Pluring nut & Copper tubing 3/16\" |
| 51 | (ad)Pluring nut & Copper tubing 5/16\" |
| 52 | (ae)Pluring nut & Copper tubing 3/8\" |
| 53 | (af) Copper tube insulation suitable for 1/2\" tube. |
| 54 | (ag) Copper tube insulation suitable for 1/4\" tube. |
| 55 | (ah) Copper tube insulation suitable for 5/8\" tube. |
| 56 | (aj) Copper tube insulation suitable for 3/16\" tube. |
| 57 | (ak) Copper tube insulation suitable for 5/16\" tube. |
| 58 | (al) Copper tube insulation suitable for 3/8\" tube. |
| 59 | (am) Condenser coil for spilt AC 1.5/ 2 TRas per existing Make orTecomseh/ Godrej/ LG / Whirlpool/ Bluestar/ Voltas/ Videocon. |
| 60 | Heavy duty Copper Thimble for AC compressor terminal |
| 61 | Taking down old unsv parts and Supply and fixing following materials/ accessories suitable for refrigerator of various capacities:- |
| 62 | (a) Charging of refrigerant R-134a gas packaging with 450gm of each can. |
| 63 | (b) Charging of refrigerant R-600 gas packaging with 450gm of each can. |
| 64 | (c) Thermostatic switch for double door frost free refrigerator Make: LG/Godrej/Whirlpool |
| 65 | (d) Thermostatic switch for single door frost free refrigerator Make: LG/Godrej/Whirlpool |
| 66 | (e) Capillary Copper tube 0.31mm |
| 67 | (f) Capillary Copper tube 0.36mm |
| 68 | (g) Drier |
| 69 | (h) Eveporator fan motor Make: LG/Godrej/Whirlpool/Videocon. |
| 70 | (j)Eveporator fan motor blade Make: LG/Godrej/Whirlpool/Videocon. |
| 71 | (k) Biometal for DD frost free Make: Godrej/Whirlpool/LG/Videocon. |
| 72 | (l) Heating Element Rod 15 Watt of size 10\"/11\"/12\" |
| 73 | (m) Defrosting Timer for frost free |
| 74 | (n) PCB Board for refigrator (As per existing make such as Whirlpool, Videocon, Samsung, LG, Bluestar, godrej etc). |
| 75 | (o) OLP+Relay Kit PTCMake:/Godrej/Whirlpool/LG/Videocon. |
| 76 | (p) Copper tubing 1/4\" |
| 77 | (q) Condensor Coil wire & tube type (180 to 310 ltrs). |
| 78 | PVC insulated multistrand copper cable 3 core size 4 Sqmm for AC, all as specified. |
| 79 | PVC insulated multistrand copper cable 3 core size 2.5 Sqmm for refrigerator and voltage stabilizer, all as specified. |
| 80 | Buitain Gas for brazing purpose packaging with 225g of each can |
| 81 | Brazing Rod |
| 82 | Bulb of 12No./14No. for refrigerator. |
| 83 | Timer switch for Refrigerator. Make:/Godrej/ Whirlpool/ LG/ Videocon. |
| 84 | Dismantling and taking out voltage stabilizer transformer unit, electric circuit board, all cable connections, complete overhauling of the system of following capacity stabilizer including repairing/ replacement of push on switch, transistor, capacitor, relay transistor, diode, condenser, voltmeter, PVC connector, indicator lamp, cutout, MCB, complete parts along with testing commissioning and transportation charges from site to workshop all as directed:- |
| 85 | (a) Upto 5KVA capacity |
| 86 | (b) 6 KVA to 10 KVA capacity. |
| 87 | Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps, conforming to C curvecomplete all as specified. |
| 88 | Metal Plug top 3 pin 15A |
| 89 | Metal Plug top 3 pin 5A |