Civil, Sanitary Repair Work, Painting And Minor Construction Work In Police Head Quarter Building, Jaipur
Tender Value
40.61 Lakhs
Estimated cost
Bid Submission
11 Jul 2022
0 days left
EMD
81220
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
jaipur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Civil, Sanitary Repair Work, Painting And Minor Construction Work In Police Head Quarter Building, Jaipur
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meter lead:For thickness of tiles 10mm to 25mm. |
| 2 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. |
| 3 | Removing aluminium/Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 4 | Dismantling stone slab/ terrazo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. |
| 5 | Taking out doors, windows and clearstory windows shutters (steel or wood) including stacking within 50 meters lead:Of area 3 square meter and below. |
| 6 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compoundconsisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound@ 0.253 kg/sqm.b) laying secondlayer of Fiber glass clothwhen the first layer is still green. Overlaps of joints of fiber cloth should not be less than 10 cm .c) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289kg/sqm mixed with water proffing cement compound@ 0.670kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all aroundd) fourth and final layer of brick tiling ‘with cement mortar or any other approved protective coarse. (which will be paid for separately) For the purpose of measurement the entire treated surface will be measured |
| 7 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) |
| 8 | 20mm nominal outer dia pipes |
| 9 | 25 mm nominal outer dia pipes |
| 10 | 32mm nominal outer dia pipes |
| 11 | Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish :20mm thick . |
| 12 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make 110 mm dia |
| 13 | Coupler 110mm dia |
| 14 | Door Bend 87.5 Dg. 110mm dia |
| 15 | Pipe Clip 110mm dia |
| 16 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).ExtraforusingMarbleprinted/Graniteshadeordarkshadetilesinsteadofwhite,grey,ivory,fumeredbrown,lightgreen,lightblueandotherlightshadesinglazedtilesandMATfinishedtiles.Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. |
| 17 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).ExtraforusingMarbleprinted/Graniteshadeordarkshadetilesinsteadofwhite,grey,ivory,fumeredbrown,lightgreen,lightblueandotherlightshadesinglazedtilesandMATfinishedtiles.Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. |
| 18 | Providing and fixing Marble stone flooring table rubbed, 15-18 mm thick over 20mm (Av.) thick base of CM 1:4 (1 cement : 4 coarse sand) jointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Keseriaji/ Abu Ambaji (Green Marble)Above 3601 Cm2 Slabs |
| 19 | Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab from 2001to 5000 Sqcm |
| 20 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 21 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure \"A\":30 mm thick .Commercial Veneer both side |
| 22 | Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. |
| 23 | Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete |
| 24 | New Plastered Surface (three or more coats) |
| 25 | Old Plastered Surface (two or more coats) |
| 26 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:Newwork(twoormorecoats)overandincludingscrappingandprimingcoatwithcement primer. |
| 27 | Applying priming coat :With ready mix pink or gray primer of approved brand and manufacture on wood work hard and soft wood. |
| 28 | Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work |
| 29 | Labour charges for removing W.C. pan (any type) of all sizes with care including all necessary fittings P or S trap. |
| 30 | Labourchargesforremovingandrefixingofurinals(alltype&sizes)includingall necessary fittings. |
| 31 | P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor |
| 32 | P & F water closet Seat Covers with brass hinges complete :Solid PVC (IS 2548 marked) grade-I White for EWC. |
| 33 | P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. |
| 34 | P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556mark). Of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS: 1703 mark) complete including cutting and making good the wall:PVC withPVCbend and superior internal fittings |
| 35 | P & F C.P. brass Urinal Spreader for stall urinal of approved make. |
| 36 | P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15mm.Brass (IS : 8931 marked- with 37 cm long pipe and nut. |
| 37 | P & F Extension Pipe for bib cocks of approved quality/make.C.P. brass of Heavy & Superior quality 100x15mm |
| 38 | P & F Grating of approved quality/make:Stainless Steel Sheet size 125mm dia. |
| 39 | Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners,4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-Charge. |
AI Tender Summary
Tender Timeline
Jun 29, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedJul 11, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJul 12, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender