Providing Renovation Special Repair Of Internal Electrification In The Administrative Building 2Nd Floor Of The Ga Printing And Stationary Department Including Advance Lighting Arrester Thereof , agartala-Tripura

Public Works Department-PWD has published Providing Renovation Special Repair Of Internal Electrification In The Administrative Building 2Nd Floor Of The Ga Printing And Stationary Department Including Advance Lighting Arrester Thereof . Submission Date for this Tender is 13-07-2022. Electrification Work Tenders in agartala Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

32857348
Providing Renovation Special Repair Of Internal Electrification In The Administrative Building 2Nd Floor Of The Ga Printing And Stationary Department Including Advance Lighting Arrester Thereof
Open Tender
Indian
Tripura
agartala
13-07-2022

Tender Details

Providing Renovation Special Repair Of Internal Electrification In The Administrative Building 2Nd Floor Of The Ga Printing And Stationary Department Including Advance Lighting Arrester Thereof

Key Value

Document Fees
INR 1000 /-
EMD
INR 15125.0 /-
Tender Value
INR 7.56 Lakhs /-

BOQ Items

Name of Work: Providing renovation / special repair of internal electrificationin the administrative building (2nd floor) of the GA (Printing and stationary) department includingadvance lighting arrester thereof.
Sl. No. Item Description
1Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with wooden switch board with bakelite cover and piano type switch including connection etc as required:-
2Short Point :-
3Medium Point :-
4Long Point :-
5Providing and fixing of 3 pin 5/6 amps plug point withpianotype 5/6ampsswitch andsocketincludingconnectionwith 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) onswitch board, earthing the 3rd pin etc. as required:-
6Providing and fixing of 3/6 pin15/16 amps plug point withpianotype 15/16ampsswitch andsocketincludingconnectionwith 2x2.5 sq. mm PVC insulated Copper conductor cable (FR) onswitch board, earthing the 3rd pin etc. as required:-
7Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:-
8Short Point :-
9Medium Point :-
10Long Point :-
11Providing and fixing of 3 pin 6/10 amps plug point withmodulartype 6/10ampsswitch andsocketincludingconnectionwith 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modularswitch board, earthing the 3rd pin etc. as required:-
12Providing and fixing of 3/6 pin 16/20 amps plug point withmodulartype 16/20ampsswitch andsocketincludingconnectionwith 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:-
13Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.
142 X 1.5 sq mm
152 X 2.5 sq mm
162 X 4 sq mm
174 X 6 sq mm
184 X 16 sq mm
194 X 35 sq mm
20Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12"x 12" having locking arrangement including CC work, holes on earth pipe etc. as required.
21Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required.
22Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required.
23Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:-
241 X 1.5 sq mm
251 X 2.5 sq mm
261 X 6 sq mm
27Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of4.06mm (8SWG) dia G.I./ Copper wire forearth connection from earth electrodes etc as required.
28Earthing with 40 mm dia G.I earth pipe (medium gauge) ( above 4.5m long normal size) i/c necessary hole etc as required.
29Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:-
3063 amps 415 volts four strip Copper busbar chamber 6 ways of size (455mmx330mmx120mm):-
31Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:-
3263 amps 415 volts TPN main switch (rewireable):-
33Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connectionas required.
346way horizontal TPN MCB DB (Double door):-
354 way vertical TPN MCB DB suitable for FP MCCB incomer upto 125 amps (Double door):-
36Supplying, installation, testing & commissioning of powder coated prewired panel board suitable for 415 volts TP MCCB as incomer & outgoing including busbar & connection as required of the following ratings & sizes:-
376 way TP MCCB outgoing & TP MCCB incomer upto 400 amps:-
38Supplying, installation, testing & commissioning of powder coated prewired digital meter module complete with ammeter, voltmeter, phase indicator lamp, control fuses, CTs, in the existing panel board including connection etc. as required:-
39Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connectionas required:-
406 to 32 amps SP MCB:-
416 to 32 amps TP MCB:-
42Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):-
4316 to 100 amps FP MCCB, Breakingcapacity 16/18KA (Thermal Magnetic):-
44160 amps TP MCCB, Breakingcapacity 25KA (Thermal Magnetic) :-
4516 to 100 ampsTP MCCB, Breakingcapacity 16/18KA (Thermal Magnetic):-
46Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:-
4740 amps FP isolator:-
48Supplying and installation of powder coated steel sheet enclosure for 415 volts MCCB (TP/FP) complete with necessary connection etc as required:-
49Enclosure suitable for MCCB upto 100 amps:-
50Supplying & fixing of 1200 mm sweep white color AC ceilingfan capacitor typedouble ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR)(ISI marked, BEE 1star/minimum service value 4.0 m3/min/W) : -
51Supplying and fixing of the following electrical accessories including necessary connection etc. as required.
52Ding dong call bell
53Musical call bell
54Electronic 4 step mini fan regulator
5532 amps DP kit kat switch:-
56Supplying and fixing of following luminaries complete withnecessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):-
57Bulk head fittings with frosted/clear glass suitable for GLS or retrofit CFL/LED (without lamp) : -
58Decorative wall mounting fancy bracket light fixture suitable for GLS or retrofit CFL/LED (without lamp)
59Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc.as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-
60Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):-
61Surface mounted box type batten suitable for double 18/20 watt integrated LED tube lamp (without lamp):-
62Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:-
63Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-
6418/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):-
659 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :-
66Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:-
67Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:-
68Supplying and fixing of 20 mm dia extra down rod (GI Pipe Medium Guage) with necessary hole for installation of ceiling fan as required.
69Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required:
70Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 noslegs (25mmx25mmx5mm MS angle20 cm long) finishedwith red oxide and 2 coat synthetic enamel paintincluding necessary cc work, mending the damages & painting etc as required:-
71Supplying & fixing of 40 mm dia G.I pipe (medium gauge) cross bar for fixing of ceiling fan/luminaries including painting & necessary accessories etc as required.
72Supplying and laying offollowing sizes XLPE insulatedPVC sheathed Aluminium conductor Un-armoured cableincludingnecessary connection etc as required.
733 core 4 Sq mm
74Drawing of armoured/un-armoured cable with proper saddling etc as required:-
75Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required.
7619/20 mm dia
77Dismantling the existing ceiling fan and making winding by (34/35/36 S.W.G) Copper wire, varnish, oiling, greasing and re-fixing the same including wiring the down rod of standard length ( up to 30 cm ) etc. as required :-
78Supplying and fixing of ESE type Lightning Protection System and Maintenance Free Chemical Earthing Solutions in/c necessary connection etc. As reqd-
79ESE-LA with Coverage Radius-30 mtr to 45 mtr (Mod-ATSTP2/58) (TRUE POWER make)
80G.I Mast ( 5 mtrs) with Accessories
81Shaddles with accessories
82Strike Counter (6 Digit)
83Copper Bonded Earthing Electrode of following specification:- Outer Dia-17.2 mm, Length-3 mtr(Model-9tp 17.2/3GBR), Free 50 kg of Chemical with Each ROD [Model-BF-C007]
84Pit Cover (Model:PC-008)
85Supply and drawing of 70sq mm Copper cable 0.5mm insulator with shaddle/ staples/ screws and other accessories as reqd (Finolex/ Havellsl Polycab make).-