Providing Special Maintenance Of Internal Electrification At The Hostel Of Regional Survey Training Institute Ad Nagar Agartala , agartala-Tripura

Public Works Department-PWD has published Providing Special Maintenance Of Internal Electrification At The Hostel Of Regional Survey Training Institute Ad Nagar Agartala . Submission Date for this Tender is 13-07-2022. Electrification Work Tenders in agartala Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

32857344
Providing Special Maintenance Of Internal Electrification At The Hostel Of Regional Survey Training Institute Ad Nagar Agartala
Open Tender
Indian
Tripura
agartala
13-07-2022

Tender Details

Providing Special Maintenance Of Internal Electrification At The Hostel Of Regional Survey Training Institute Ad Nagar Agartala

Key Value

Document Fees
INR 1000 /-
EMD
INR 18773.0 /-
Tender Value
INR 9.38 Lakhs /-

BOQ Items

Name of Work: Providing special maintenance of Internal Electrification at the hostel of Regional Survey Training Institute, A.D. Nagar, Agartala.
Sl. No. Item Description
1Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:-
2Short Point :-
3Medium Point :-
4Long Point :-
5Providing and fixing of 3 pin 6/10 amps plug point withmodulartype 6/10ampsswitch andsocketincludingconnectionwith 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modularswitch board, earthing the 3rd pin etc. as required:-
6Providing and fixing of 3/6 pin 16/20 amps plug point withmodulartype 16/20ampsswitch andsocketincludingconnectionwith 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:-
7Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.
82 X 1.5 sq mm
92 X 2.5 sq mm
104 X 4 sq mm
114 X 10 sq mm
12Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:-
131 X 1.5 sq mm
14Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12"x 12" having locking arrangement including CC work, holes on earth pipe etc. as required.
15Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required.
16Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required.
17Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of4.06mm (8SWG) dia G.I./ Copper wire forearth connection from earth electrodes etc as required.
18Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:-
1963 amps 415 volts four strip Copper busbar chamber 6 ways of size (455mmx330mmx120mm):-
20Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:-
2163 amps 415 volts TPN main switch (rewireable):-
22Supplying and installation of fuse unit kitkat/HRC/HBC of the following ratings in existing main switch/panel board including necessary connection etc as required:-
2363 amps kitkat porcelain fuse unit with base(rewireable):-
24Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connectionas required.
254way horizontal TPN MCB DB (Double door):-
266way horizontal TPN MCB DB (Double door):-
27Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connectionas required:-
286 to 32 amps SP MCB:-
2940/50/63 amps FP MCB:-
30Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc.as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-
31Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):-
32Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:-
33Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-
3418/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):-
359 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :-
36Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-
3760 watt LED street light fixture with integral driver and secondary lens (IP 66):-
38Supplying & fixing of 1200 mm sweep white color AC ceilingfan capacitor typedouble ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR)(ISI marked, BEE 1star/minimum service value 4.0 m3/min/W) : -
39Supplying and fixing of the following electrical accessories including necessary connection etc. as required.
4032 amps DP kit kat switch:-
41Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:-
42Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required:-
43Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:-
44Supplying and fixing of the following sizes wooden switch boards with 3mm thick bakelite cover etc. as required.
45102mm x 178mm (4" X 7") :-
46Supplying and laying offollowing sizes XLPE insulatedPVC sheathed Aluminium conductor Un-armoured cableincludingnecessary connection etc as required.
473 core 4 Sq mm
48Drawing of armoured/un-armoured cable with proper saddling etc as required:-
49Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:-
5025 mm dia
51Supplying and fixing of following luminaries complete withnecessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):-
52Bulk head fittings with frosted/clear glass suitable for GLS or retrofit CFL/LED (without lamp) : -
53Supplying and fixing of the following modular accessories including necessary connection etc. as required.
544 step fan regulator (1M):-
55Blank plate (1M):-
56Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 noslegs (25mmx25mmx5mm MS angle20 cm long) finishedwith red oxide and 2 coat synthetic enamel paintincluding necessary cc work, mending the damages & painting etc as required:-
57Supplying of 25 cm long ‘L’ hook made with 40mm x 6mm MS flat and fixing with necessary fasten nuts including finishing, painting etc as required.