}

Certain Sanction Works ( 05 Nos ) In Age Br-I And Age Em Under Ge Babina- 1 Excavationin Trenchesnot Exe 1.5 Mtrs Wideand Not Exe 1.5 Mtr In Depth And Getting Outin Any Type Of Soiletc Complete All As Specified And Directed . 2 Excavation In , babina-Uttar Pradesh

Military Engineer Services-MES has published Certain Sanction Works ( 05 Nos ) In Age Br-I And Age Em Under Ge Babina- 1 Excavationin Trenchesnot Exe 1.5 Mtrs Wideand Not Exe 1.5 Mtr In Depth And Getting Outin Any Type Of Soiletc Complete All As Specified And Directed . 2 Excavation In . Submission Date for this Tender is 23-07-2022. Wrenches and Drivers Tenders in babina Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

32853518
Corrigendum : Certain Sanction Works ( 05 Nos ) In Age Br-I And Age Em Under Ge Babina- 1 Excavationin Trenchesnot Exe 1.5 Mtrs Wideand Not Exe 1.5 Mtr In Depth And Getting Outin Any Type Of Soiletc Complete All As Specified And Directed . 2 Excavation In
Open Tender
Indian
Uttar Pradesh
babina
23-07-2022

Tender Details

Certain Sanction Works ( 05 Nos ) In Age Br-I And Age Em Under Ge Babina- 1 Excavationin Trenchesnot Exe 1.5 Mtrs Wideand Not Exe 1.5 Mtr In Depth And Getting Outin Any Type Of Soiletc Complete All As Specified And Directed . 2 Excavation In Post Holes ( Or Similar Holes ) Each Not Exc 0.5 Cum , Getting Out In Any Type Of Soilsandremoving Surplus Soil To A Distance Not Exc 50M And As Directed. 3 Surface Excavation Not Exceeding 30 Cm Deep And Averaging 15 Cm Deep And Getting Out In Hard / Dense Soil Comlete All As Specified And Directed. 4 Returning, Filling In, Including Spreading, Watering And Well Ramming In Layers N. Exc 25 Cm Thick In Any Type Of Soil Complete All As Specified And As Directed. 5 Removing Excavated Soils / Material To A Distance N Exc 50M And Deposited Where Directed At A Level N. Exc 1.5M Above The Starting Point Complete All As Specified And As Directed. 6 M&L For Moorum Laid In Layers N Exc 15 Cm Thickness , Spread , Levelled , Rammed And Watering As In Floorsetc Complete And All As Specified 7 M&L For Hard Core Of Broken Boulders / Stone Of Gauge N Exc. 63 Mm, Deposited, Spreading, Leveling Watering And Well Ramming To True Surface In Layers Not Exceeding 15 Cm Thick Each Layer Complete All As Specified And Directed. 8 Demolition Of Brick Work / Stone Masonary Built In Cement Mortar Of Nay Description , Any Position And Anylocation And As Direcetd 9 M&L For Brick Work With Fly Ash Bricks ( Fasb ) Straight Or Curved On Plan Exc 6 M Radius Built In Cement Mortar ( 1 : 4 ) Etccomplete All As Specified And As Directed. 10 M&L For Pcc 1:3:6 Type C 2 Using 40Mm Graded Stone Agg As In Filling And Mass Concrete , Sub Base / Flooring Complete All As Specified And Directed. 11 M&L For Pcc 1:4:8 Type D2 Using 40Mm Graded Stone Aggregatesas In Foundation Filling Etccomplete All As Specified And Directed. 12 M&L For Pcc 1:2:4 Type B-2 Using 40Mm Graded Stone Agg As In Filling And Mass Concrete, Sub Base / Flooring Complete All As Specified And Directed. 13 M & L For Pcc Work Of Flexural Strength Of 40 Kg / Sqcm Using Cement 400Kg / Cumas In Pavement , Floors & Hard Standing, Laid In Panels Not Exceeding 30 Sqm Each , Panel Shall Be Formed Using Mild Steel Members Of Adequate Size And Thichness To Create 10 Mm Wide Joints , Surfaces Ofconcrete Finished Even And Fair To Desire Level Etc Complete All As Specified And As Directed. Note : ( I ) Cost Of Sample Testing For Design Mixto Ensure Flexural Strength 40 Kg / Sqcm Will Be Borne By The Contractor . Min Cement Content Shall Be 400 Kg / Cum Of Concrete . In Case Cement Required More Than 400 Kg Shall Deemed To Be Included In The Quoted Rate And Nothing Extra Shall Be Admissible On This Account . ( Ii ) Joint Shall Be Measured And Paid Seperately . 14 M&L For Filling Of Contraction Joints 10 Mm Wide X 30 Mm Deep And Tfilled With Sealing Compound Grade A Etc Complete As Directed 15 M & L For Precast Rcc1:1.5: 3 Type A-1 Using 20 Mm Graded Stone Aggregate As In Lintel Upto 1.50 Mtr Span Etc Complete All As Specified And As Directed. Note : Reinforcement Shallbe Paid Seperately 16 S&F, 2Nd Class Hard Wood ( Sal ) As In Scantling, Wrought Timber Frame Work As In Members Of Trusses Like Rafter , Purlins Etc Similar Etc Complete And As Directed. Note : The Moisture And Species Test Is Manadatory Prior To Used Timber And Shall Be Got Tested From Govt Lab Or From Nibl Approved Lab . No Payment Of Timber Shall Be Made Unless Got Tested And Test Results Thereof Found Satisfactory 17 M&L For Mild Steel Tmtbars8mm Dia, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hookingends And Binding With And Includingmild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clips Etc Complete All As Specified And Directed .Make : As Specified In Tender Documents 18 S&F Mild Steel Work As In Tubular Trusses Including Special Shaped Washer Etc Complete Using Erw Or Induction Butt Welded Tubes Conforming To Is-1161-1979 Grade St-240 With And Including One Shop Coat Of Zinc Chrominium Primer Paint Complete All As Specified And As Directed. 19 S&F Mild Steel Work As In Roof Trusses ( Framed ) Trussed , Purlins , Crane Gentries Rails And Fastenings And Heavy Brackets Framing ( Beam, Tee, Angle, Channel Or Flat Sections ) Incl Distance Pieces , Cleats Etc Of 290Gde - E-165 Etc Complete All As Specified And As Directed. Make : As Specified In Tender Documents 20 S &F Mild Steel Hold Flat Iron 40X5 Mm Thick As In Wind Tie Over Roof Including Securing Bolts Including Driling Holes Etc Complete And As Directed Make : As Specified In Tender Documents 21 S&F Mild Steel ( Plain ) Plates , Square Cut Or Notched ( Ordinary And Counter Sunk ) Forming Holes Of Suitable Dia If Requiredand Fixed To Pipe By Electric Welding Alround The Neck Of Pipe Etc Complete And As Directed. 22 S&F Mild Steel Screw Bolts ( Machine Made ) With Hexagonal Or Square Heads At One End And Screwed The Other, Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, N Exc 10 Cm Length And 11 To 15 Mm Dia 23 Dismantling Of Timber Scantling 40 Sqcm And Over In Section Fixed In Any Position As Framed Work Complete All As Specified And Directed 24 Taking Out / Dismantlingof Existing Roof Treatment Of Any Description , Any Position Over Roof Including Taking Out Plain Cement Concrete Of Any Description To The Thckness As Directedetc Complete And Including Lowering Down Complete Waste Materials To The Ground On A Place Where Directed And Includingremoval Of The Same To A Distance Exc 250 Mtr But N Exc 500 Mtr As Directed .Note : The Cost Of Lowering Down And Removal Deemed Included In Unit Rtae Quoted By The Tenderer. 25 M&L For Cutting Out Cracks To V Section In Existing Roof Or Terracing , Cleaning Out , Wetting And Sealed Solidly With Hot Mixture Of Bitumen And Dry Sand In Proportion Of 1:1 By Weight Etccomplete And As Directed. 26 M&L For Cutting Grooves In Brick Wall 75Mm Wide And 65Mm Deep And Shaping Horizontal Face Of Groove Sealed With Cement Mortar 1:3 Complete And As Directed. 27 M&L For P.C.C 1:2:4 Type B-1 Using 20 Mm Graded Stone Aggregate As In Padding Laid To Slope Over Roof And Surface Finished Even And Fairetccomplete All As Specified And As Directed. Note : The Thickness Of Pcc Shall Not Be Exceeded More Than75 Mm At Any Place 28 M&L For P.C.C 1:2:4 Type B-0 Using 12.5 Mm Graded Stone Aggregate As Incoping Andon Roof Etccomplete All As Specified And As Directed. 29 Supply Only Water Roofing Compound ( Liquid ) Isi Marked Etc Complete And As Directed 30 M&L For 10 Mm Thick Rendering In Cement Mortar 1:4 On Concretesurfaces Of Roof When Concrete Is Stillgreen Mixed Withwater Proofing Compound ( Liquid ) @ 200 Ml Perbag Of Cement Of 50 Kgs , Surface Finished Even And Fair Enough To Receive Water Proofing Traetment Etc Complete All As Specified And As Directed. Note : Wpc Shall Be Measured And Paid Seperately 31 M&L For Providingwater Proofing Treatment Over Roof By Applying The Following Operations :- ( A ) Preparation Of Plastered Surface By Cleaningwith Water And Leave The Sufaces Till To Become Surface Total Dry . ( B ) Applyingfirst Coat Of Bitumen Primer Conforming To Is-3384 @ 0.4Kg / Sqm On Plastered Surface ( C ) Applying App Based Polymeric Membrane 3Mm Thick ( Minimum Thickness ) And Weightnot Less Than 3Kg / Sqm , Reinforced With Polyester Non Woven Fabric ( Wt Not Less Than 150 Gms / Sqm ) Over On Primed Surfacelaid With 100Mm Side Lap / End Lap On Prepared Surfaces As Per Manufacturers Instructions And Under Strict Supervision Of ManufacturerS Tenchnical Representativeetc And Applying Two Coats Of Bituminous Based Aluminum Paint @ 100 Ml / Sqm Each Coat Etc Complete And As Directed. Note : Testing Of App Membrane Is Mandatory And Contractor Will Not Be Allowed To Carry Out The Work Untill Results Are Obtained And Found Satisfactory .Cost Of Testing And Samples ( 3Nos ) Deemed To Be Included In Unit Rate Quoted By Thetendrer And Nothing Extra On This Account Will Be Admissible . ( Ii ) The Cost Of Casting Onecement Plate Of Size 600 Mm X 450 Mm , 10 Mm Thick Rendering In Cm 1:3 In Each Building Incl Writing Materials Shall Deemed To Be Included In The Unit Rate Quoted By The Tenderer. 32 M &L For Plain Concrete Cement Tiles ( Cement ) 30Cm X 30Cm X 25Mm Set And Jointed And Pointedin Neat Cement Slurry On Roof Over & Including 15Mm Thick Screed Bed In Cm ( 1: 4 ) And Joint Between The Tiles To Be Filled With Chemiucal Like Grout Etc Complete All As Specified And Directed. 33 Dismantling Wall / Ceiling Boards Of Any Description Any Thickness Incl Exiting Snap Grid Framework Of Any Descriptionand As Directed. 34 M&L For Snap Grid ( 600 X600 Mm ) Ceiling Using Aluminium Anodised Sectionsie Main Tee Section Of 36.5X25x1.4Mm Size ( Wt Not Less Than 0.24Kg / Rm ) , Wall Angle Of Size 40X25x2mm Size ( Wt Not Less Than 0.36Kg / Rm ) , Cross Tee Section 23.5X26.4X1.4Mm Size ( Wt Not Less Than 0.191Kg / Rm ) Andsnap Grid Shall Be Fixed To Ceiling By Supporting Hangers Consisting Of 6 Mm Dia Mild Steel Bar Made To Shape Including Providing Mild Steel Flat Iron Cleat With 40X3 Mm And Fixed With Expansion Dash Fastener N Exc 1.20 Mtr Both Ways Fixed To Roof Etccomplete All As Directed. 35 M&L For For 4 Mm Thick High Pressure Steam Cured Non Asbestos Fiber Cement Designer Board Of Size 600Mm X 600Mm As In Ceiling Complete All As Specified And Directed With And Including Aluminium Anodised Snap Grid Frame. 36 Dismantling Asbestos Cement , Galvalume , Fibre Sheet ( Plain , Corrugated , Semi Corrugated ) And As Direcetd 37 S&F Pre Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thickcolouredhaving Tensile Strength Of 550 Mpa As In Roof Covering Andfixed With Self Tapping Screws And As Directed . 38 S&F Pre Painted Galvalume Aluminium Zinc Coating Gi Basedplain Steel Sheet 0.50Mm Thickcolouredhaving Tensile Strength Of 550 Mpa As In Cladding / Wall Fixed With Self Tapping Screws And As Directed . 39 M&L For 75 Mm Thick P.C.C 1:3:6 Type C-1 Using 20 Mm Graded Stone Aggregate As In Plinth Protection Laid In Alternate Panels Made Of 10 Mm Thick Plywood ( Size Of Each Panel Shall Not Exceed 12 Sqm ) And Finish The Surface Even And Smooth Withoutusing Extra Cement Including Filling Of Jointwith Bitumen Mastic ( 1 Part Bitumen Mixed With 3 Part Dry Sand ) Etc Complete All As Specified And As Directed. Note : Cost Of Form Work For Forming Joints And Jointing Materials Deemed To Be Included In Unit Rate Quoted By The Tenderer. 40 M&L For Non Skid Ceramic Coloured Tiles 7 To 8 Mm Thick ( Square / Rectengular ) Dark ( Premium Quality ) Area Of Each Tile Exceeding 0.11 Sqm But Not Exc 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurryand Pointed In White Or Coloured Cement To Match Over 15 Mm Thick Screed Bed In Cm 1:6 Etccomplete All As Specied And Directed. 41 M&L Glazed Ceramic Coloured Tilesdark ( Premium Quality ) 7 To 8 Mm Thick Size 300X600 Mm Joint Free Over 15 Mm Thick Rendering In Cement Mortar 1:4 In Skirting / Dado Etc, Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Shade Of Tile Etc Complete All As Specified And Directed . 42 Taking Down Cement Plaster Of Any Description Built In Cement Mortar On Brick Or Stone Walls Etc Including Racking Out Joints, Hacking For Key, Scrubbingdown With Water Etc.Complete All As Specified. 43 M & L For 15 Mm Thick Rendering In Cement Mortar 1: 6 On Fair Faces Of Brick Work Or Concrete Surfaces , Surface Finished Even And Smoothwithout Using Extra Cement Complete All As Specified And As Directed. 44 M & L For 15 Mm Thick Rendering In Cement Mortar 1: 6 On Other Than Fair Faces Of Brick Work Or Stone Masonary , Surface Finished Even And Smoothwithout Using Extra Cement Complete All As Specified And As Directed. 45 M & L For Prepration Of Newly Plastered Surfaces Of Walls Appying Two Coat Of Cement Base Paint Over A Coat Of Primeretc Complete All As Specified And As Directed . 46 M & L For Complete Removal Of Existing Treatment From Walls And Appying Two Coat Of Cement Base Paint Over A Coat Of Alkali Resistant Primerincluding Necessary Prepration Of Surface Complete All As Specified And As Directed. 47 M & L For Applying Two Coat Of White Wash On Wallsincludingnecessary Preparation Ofsurfaces All As Specified And Directed. 48 M&L For Preparation Of Old Decorated Surfaces Of Wall Including Cornices, Plastered Or Unplastered Surfaces By Brooming Down Or Steel Wire Brushing To Remove Dust, Dirt And Loose Scales Of Lime Wash And Other Foreign Material Etc And Applying Two Coat Of White Wash Complete All As Specifiedand Directed. 49 M&L For Preparing New Surfaces Of Steel Of Any Description, Over 10Cm In Width Or Girth Not Otherwise Described And Applying Two Coats Of Synthetic Enamel Paints Over One Coat Of Red Oxide Primer All As Specified. 50 S&F 100 Mm Bore Cast Iron Soil Waste And Vent Pipe Spun Pipein Any Length With Or Without Ear And Jointed In Cm 1:1 Fixed To Wallswith Ms Clamp Made Of Flat Iron 50X5 Mm And Bolt Grouted In Wall Withpcc 1:2:4 Type B-0 Using 12.5 Mm Graded Stone Aggregates And Taking Out Existing Pipe Of Any Description Etc Complete All Asspecified And Directed. 51 S&F Cast Iron Bend Any Radius 100 Mm Bore Etc Compete And As Directed 52 Taking Up Or Down Existing Steel Tubing And Connections Including Cleaning For Refixing Etc Complete All As Specified And As Directed For 15 Mm Bore 53 Taking Up Or Down Existing Steel Tubing And Connections Including Cleaning For Refixing Etc Complete All As Specified And As Directed For 20 Mm Bore 54 Supplying, Fixing, Jointing And Testing 15 Mm Dia Galvanised Iron Tubing Medium Grade Isi Marked With All Fitting Such As Bends, Elbow, Socket, Reducer Etc And Fixed To Wall Or Laid In Floor Complete All As Specified And As Directed 55 Supplying, Fixing, Jointing And Testing 20 Mm Dia Galvanised Iron Tubing Medium Grade Isi Marked With All Fitting Such As Bends, Elbow, Socket, Reducer Etc And Fixed To Wall Or Laid In Floor Complete All As Specified And As Directed 56 Taking Down Old Existing Unserviceable Tank Pvc ( Hdpe ) And Of Capacity Exc250 Ltrs But N Exc 500Ltrs Complete As Direcetd 57 S&F 500 Ltr Capacity Or Rotational Moulded Polyethylene Water Storage Tank ( Cylindrical Vertical With Closed Top ) White , Isi Marked , Triple Layered Construction Hoisted And Fixed In Position Including S&F 20Mm Dia Gi Pipe Medium Grade Washout Pipe 450Mm Long With Plug And 20Mm Dia Gi Pipe Medium Grade Overflow Pipe 600Mm Long With Fitting Etc Complete All As Specified In Ssr Part -I 2009 Complete All As Specified And As Directed. 58 S & Fball Valve Highpressure Of Ptmt With Epoxy Coated Aluminium Rod & Highdensityplastic Ball Screwed For Iron Pipe 20 Mm Dia And Fixed In New Tank ( Minimum Weight 20Mm 210 Gm ) Complete All As Specified. 59 S & F In Repairs Ball Valve Highpressure Of Ptmt With Epoxy Coated Aluminium Rod & Highdensityplastic Ball Screwed For Iron Pipe 20 Mm Dia And Fixed In New Tank ( Minimum Weight 20Mm 210 Gm ) Complete All As Specified. 60 S&F20 Mm Gun Metal Gate Valve ( Isi Marked ) With Iron Wheel Head Screwed Both Ends For Iron Pipe Etc Complete As Directed. 61 S&Fin Repair 20 Mm Gun Metal Gate Valve ( Isi Marked ) With Iron Wheel Head Screwed Both Ends For Iron Pipe Etc Complete As Directed. 62 Demolition Of Cement Concrete ( Unreinforced ) Inground Floors And Paving N. Exc 15 Cm Thickness Below Or Above Ground Level Complete All As Specified And As Directed. 63 Taking Down Carefully Aluminium / Copper Point Wiring On Battenor In Pvc Conduit Or In Ms Conduit With Gi Earth Wire Etc ( For Light, Fan, Socket Or Power Point ) Complete , Including Taking Out Fixtures And Fittings Such As Switches , Ceiling Roses, Pendents, Regulators , Sockets, Light Fitting Etcremoving Materials To Store For Keeping In Safe Custudy Or For Taking Credit ( As Per Schedule Of Credit For Dismantled / Taken Out Items ) And Making Goodthe Disturbedsurfaces Of Walls, Floors, Ceilings Etc And As Directed . 64 Taking Down Carefullyexisting Wooden Board , Main Switch, Mcb Db Boxes, Tpn Boxes, Cut Out, Etc Of Any Size Anycapacity Fromboards Completeall As Specified And As Directed. 65 Taking Down Carefully Sub Main Wiring With Any Cable / Service Connection Twin Core From Wall / Lt Pole Of Any Size Of Aluminum With Wooden Batten And Or Through Rigid Conduit Including Gi Wire And Making Good The Disturbed Surfaces Of Walls, Roofs, Floors Etc Complete All As Specified And As Directed. 66 M & L For Surfacepoint Wiring ( Inpvc Conduit ) One Light Pointcontrolled By One Switch With Pvc Insulated And Unsheathed Flame Retardant Low Smoke ( Frls ) Cable Of 1.5 Sqmm ( Nominal Area ) With Stranded Copper Conductor Single Core 1100 Volts Grade In And Including Non Metelic Rigid Pvc Conduit Not Less Than 19 Mm Dia, Clip, Withms Terminal Boxes ( Not Less Than 1.6Mm Thick ) Including Earth Dollywithframe Plates With Matching Cover Plates All Modules Including 1.5 Sqmmstranded Copper Conductor Green As Continuous Earth Wire With Lugs Complete All As Specified And As Directed . Note : Quoted Rates Shalldeemed To Be Inclusive For Provision Of Covering Sunken Boards / Terminal Boxes / Junction Boxes Of Any Shape And Size With 3Mm Thickisi Marked Hylam Sheet / Backlite Sheet Cover Fixed With Suitable Brass Screws And Cup Washers. 67 All As Per Srl Item No. 66 Above But One Fan / Exhaust Point Controlled By Oneswitch ®Ulator. 68 All As Per Srl Item No.66 Above But One 3 / 5 Pin5 Amp Socket Outlet Point Controlled By Oneswitch On Independent Board. 69 All As Per Srl Item No.66 Above But One 3 / 5 Pin5 Amp Socket Outlet Point Controlled By Oneswitch On Same Board. 70 Description All As Per Item No 66Above But For Power Point Wiring Using 2.5 Sqmm Single Core Multi Stranded Copper Conductor Pvc Insulated And Unsheathed, Flame Retardant Low Smoke ( Frls ) Cable For 3 / 6 Pin 15 Amp Socket Outlet Controlled By One Switch On Independent Board With And Including 1.5 Sqmmstranded Copper Conductor Green As Continuous Earth Wire With Lugs Complete All As Specified And As Directed. 71 M & L For Concealedpoint Wiringone Light Pointcontrolled By One Switch With Pvc Insulated And Unsheathed Flame Retardant Low Smoke ( Frls ) Cable Of 1.5 Sqmm ( Nominal Area ) With Stranded Copper Conductor Single Core 1100 Volts Grade In And Including Non Metelic Rigid Pvc Conduit Not Less Than 19 Mm Dia, Clip, Withms Terminal Boxes ( Not Less Than 1.6Mm Thick ) Including Earth Dollywithframe Plates With Matching Cover Plates All Modules Including 1.5 Sqmmstranded Copper Conductor Green As Continuous Earth Wire With Lugs Complete All As Specified And As Directed .Note :- ( I ) Quoted Rate Shall Be Deemed To Include The Cost Of Cutting Chases In Walls / Pillars / Column Etc. Of Any Description For Concealing The Conduit To Required Depth & Making Good The Disturbed Surface In Cement Mortar 1:4 Including Finishing The Surface To Match With The Existing Surface. The Portion Of Point Wiring At Ceiling Shall Be In Surface Pvc Conduit / Casing & Caping Of Suitable Size As Directed Fixed On Ceiling Surface With Using Pvc Rawl Plugs. ( Ii ) Fittings Like Switches, Sockets, Regulators, Lamp Holders, Light Fittings Shall Be Measured And Paid For Separately Under Appropriate Item Of Schedule `A. ( Iii ) The Quoted Rates Shall Be Deemed To Be Inclusive For Provision Of Covering Sunken Boards / Terminal Boxes / Junction Boxes Of Any Shape And Size With 3Mm Thickisi Marked Hylam Sheet / Backlite Sheet Cover Fixed With Suitable Brass Screws And Cup Washers 72 All As Per Srl Item No. 71 Above But One Fan Point Controlledby Oneswitch ®Ulator. 73 All As Per Srl Item No.71 Above But One 3 / 5 Pin5 Amp Socket Outlet Point Controlled By Oneswitch On Independent Board. 74 All As Per Srl Item No.71 Above But One 3 / 5 Pin5 Amp Socket Outlet Point Controlled By Oneswitch On Same Board. 75 Description All As Per Item No 71Above But For Power Point Wiring Using 2.5 Sqmm Single Core Multi Stranded Copper Conductor Pvc Insulated And Unsheathed, Flame Retardant Low Smoke ( Frls ) Cable For 3 / 6 Pin 15 Amp Socket Outlet Controlled By One Switch On Independent Board With And Including 1.5 Sqmmstranded Copper Conductor Green As Continuous Earth Wire With Lugs Complete All As Specified And As Directed. 76 S & F Switch Piano Flush Button Type10 Amp, Single Pole , One Way , Ac , 230 Volts , 50 Hz Complete All As Specified And Asdirected. 77 S&Fsocket Outlet 2In 1 , 3 Pin , 10 Amp , Ac , 230 Volts , 50 Hzcomplete All As Specified And Asdirected. 78 S & F Switch Piano Flush Button Type 20 Amp, Single Pole, One Way , Ac , 230 Volts , 50 Hz Complete All As Specified And Asdirected. 79 S & Fsocket Outlet 2 In 1, 10 Amp And 20 Amp, Ac , 230 Volts , 50 Hz Complete All As Specified And Asdirected. 80 S & Fdelux Fanregulator Rotary, Step Type , Ac , 240 Volts , 50 Hz Complete All As Specified As Directed. 81 S & Flamp Holder, Pvc / Urea Type With Back Plate , Ac , 230 Volts , 50 Hz , Isi Marked Suitable For Batten Fittingscomplete All As Specified As Directed 82 S&F Ceiling Rose, Surface Bakelite 65 X50mm Three Brass Terminals, Ac , 230 Volts , 50 Hz Isi Marked Completeall As Specified And Asdirected. 83 S & F9 / 10W Led Retrofit Ball Lamp Holder Base B-22, Bipin Type Ac 230 Volts 50 Hz With Pf Not Less Than 0.95 With Polycorbonate Body And Aluminium Heat Sink Complete All As Specified As Directed. 84 S&F For Sub Main Wiring With Pvc Insulated, Unsheathedflame Retardant Low Smoke ( Frls ) 2 Single Core Cable 1100 Volts Grade Withcopperconductor Of Size 10 Sq Mm ( Nominal Area ) Multi Stranded Drawn Into New Non Rigid Metellic Pvc Conduit With And Including 6 Sqmm Green Stranded Copper Conductor As Contineous Earthwire Withlugs Complete All As Specified And As Directed. Note:Two Run Of Single Core Pvc Cable With One Run Of Earth Conductor Cable And Conduit Shall Be Measured As One Unit. ( Ii ) Cost Of New Pvc Conduit Including Conduit Accossoriesshall Be Deemed To Be Included In Unit Rate Quoted By The Tenderer . 85 S&F For Sub Main Wiring With Pvc Insulated, Unsheathedflame Retardant Low Smoke ( Frls ) 2 Single Core Cable 1100 Volts Grade Withcopperconductor Of Size 6 Sq Mm ( Nominal Area ) Multi Stranded Drawn Into New Non Rigid Metellic Pvc Conduitwith And Including 4 Sqmm Green Stranded Copper Conductor As Contineous Earthwire Withlugs Complete All As Specified And As Directed. Note:Two Run Of Single Core Pvc Cable With One Run Of Earth Conductor Cable And Conduit Shall Be Measured As One Unit. ( Ii ) Cost Of New Pvc Conduit Including Conduit Accossoriesshall Be Deemed To Be Included In Unit Rate Quoted By The Tenderer . 86 S&F Tpn Db- Dpx 125 Mccb Dbs 4 Way Double Door With Provision For Dpx 125 Mccb And As Incomer And Sp / Tp Mcbs As Out Going No Of Modules Dpx 125 + 12 Etc Complete All As Specified And Directed. 87 S&F Mccb , 200Amps, 415 Volts, 4 P , 50Hz, Having 36 Ka Rupturing Capacitywith Electronic Trip Arrangment And Setting Screw Upto 70% Including Making Connection With Excisting Cable With Connection And Materials Like Copper Strips, Lugs, Nut & Bolts Etc. Complete All As Specified And As Directed . 88 S&F Mccb , 100Amps, 415 Volts, 4 P , 50Hz, Having 25 Ka Rupturing Capacitywith Electronic Trip Arrangment And Setting Screw Upto 70% Including Making Connection With Excisting Cable With Connection And Materials Like Copper Strips, Lugs, Nut & Bolts Etc. Complete All As Specified And As Directed . 89 S&F Mccb , 63Amps, 415Volts, 3 Phase, 50Hz, Having 35 Ka Rupturing Capacity, 415 Volts With Electronic Trip Arrangment And Setting Screw Upto 70% Including Making Connection With Excisting Cable With Connection And Materials Like Copper Strips, Lugs, Nut & Bolts Etc. Complete All As Specified And As Directed . 90 S&F Mccb , 63Amps, 415Volts, 3 Phase, 50Hz, Having 16 Ka Rupturing Capacity, 415 Volts With Electronic Trip Arrangment And Setting Screw Upto 70% Including Making Connection With Excisting Cable With Connection And Materials Like Copper Strips, Lugs, Nut & Bolts Etc. Complete All As Specified And As Directed . 91 S&F Sheet Metal Enclosure Box With Hinges Door Suitable For Mccb 63 Amp To 100 Amp With All Necessary Fixing Arrangementetc For Walletc. Complete All As Specified And As Directed . 92 S&Fsheet Metal Enclosure Double Door Concealed Suitable For Distribution Boards When Mcbs To Be Used Having 100Amp Rated Bus Bar 8 Ways 240 V Complete All As Specified And As Directed. 93 S&Fmcb Single Pole And Neutral 40 Amp 240 V , 10Ka , C Series, Isi Marked Complete All As Specified And As Directed With Copper Lugs. 94 S&Fmcb Single Pole And Neutral 63 Amp 240 V , 10Ka , C Series, Isi Marked Complete All As Specified And As Directed With Copper Lugs. 95 S&Fmcb Tpn 63 Amp 240 V , 10Ka , Cseries, Isi Marked Complete All As Specified And As Directed With Copper Lugs. 96 S&Fmcb Single Pole 6 To 32Amps 240 V, 10Ka, C Series, Isi Markedcomplete All As Specified And As Directed With Copper Lugs. 97 S&Fin Repairs 20 W Led, 6000K Decorative Ultra Slim Linear Fitting , Extruded Aluminium , Environmental Friendly, Energy Efficient Incl 20 W Lamp Fitted Incl Wiring Upto And Terminating Into Existing Ceiling Rose Complete All As Specified And As Directed. 98 S&F 36W 2X2 Led Fitting Ultra Mordern Ceiling Mounted Luminaire Suitable For Armstrong / Grid Ceiling In Ms Housing With High Brightness Leds Incl Wiring Upto And Terminating Into Existing Ceiling Rose. 99 S&F Wall Mountedfan 600 Mm Sweep Turbo Force Aerodynamic Desined Blade For High Air Deleivery Complete Incl All Necessary Fixing Arrangements And As Directed. 100 S&F Ceiling Fan 1200Mm Sweep Bee Ratedac Single Phase 230 Volts Etc Connecting With Flexible Cable 3 Core Copper Conductor Of Size 23.0 / 0076 Of Suitable Length From Celling Rose Complete All Necessary Arrangement Of Hanging Of Celling Fan ( Gi Pipe Hook Etc ) As Specified And As Directed. 101 S & F Exhaust Fan, Ac , Singe Phase , 230 / 240 Volts , 300 Mm Sweep , Noiseless Light-Weight Rust Proof Steel Body Self Closing Louvers And Blades, Speed1400complete With All Arrangement Of Making Hole Complete All As Specified And As Directed. 102 S&F For Replacement & Testing Commissioning Of Outdoor Type Bus Bar Panel Padestel Type Weather Proofms Cubical Panelboard Made Of3 Mm Crca Ms Sheet , Size 110 Cm X 80 Cm X 40 Cm, 4 Nos Of Aluminium Bus Bar Of 500 Amp Capacity Including Providing Mccb , 4 Pole , 320 Amp , Repturing Capacity35 Ka , Adjustable Type ( Ics =Icu=100% ) Including One Coat Of Redoxide And Two Coat Of Enamel Paint Powder Coated, Mounted On Mild Steel Channel Of Suitable Sizeand Providing Pcc Work Inpcc1:3:6 Type C-2, 60 Cm Height Above Gl Over 300 Mm Thick Pcc 1:4:8 Type D-2 ( Using 40Mm Graded Crushed Stone Aggregate ) In Foundation For Fixing Panels & Aluminium Busbar Chanel Insulated With Colour Coated Heat Shrinkable Sleaves And Mounted On Dmc / Epoxy Insulator All As Specified & Directed. 103 S&Fnew Generation Energy Saving And Environmental Friendly Long Life Led Flood Light Made Up Of Innovative Die Cast Aluminium Housing High Power Led As Lighting Source With Ip - 66 Power Consumption 30 Watt Complete Input Voltage Of 150-240 Volt ( Nominal Rated Voltage 240 Volt ) Completeall As Specified And Directed. 104 S&F In Replacement New Generation Security Light Fitting 1 X 36 W Led , Envoirnmental Friendly Long Life , Made Up Of Of Innovative Die Cast Aluminium Housingwith High Power Led As Light Source Withip 66 Protection , Power Consumption 45 Watt Complete Input Voltage Of 150 -240 Volt ( Nominal Rated Voltage 240 Volt ) Includingelectric Connection With1.5 Sqmm 3 Core Pvc Insulated And Pvc Sheathed Cable Stranded Copper Conductor From Junction Box To Security Light Etc Complete As Specifiedand As Directed. 105 Supplying , Laying & Testing In Replacement Cablexlpe Insulatedscreenedpvc Bedded Armoured With Galvanised Steel Wire Or Tape, Electric Power Cable Heavy Duty 1100 Volt Gradealuminium Conductor Of Size 50X3.5Coreincluding Taking Out Acsr / Ug Cable From Any Location Etc Complete All As Directed. Etc Complete All As Directed. 106 Supplying , Laying & Testing In Replacement Cablexlpe Insulatedscreenedpvc Bedded Armoured With Galvanised Steel Wire Or Tape, Electric Power Cable Heavy Duty 1100 Volt Gradealuminium Conductor Of Size25x3.5Coreincluding Taking Out Acsr / Ug Cable From Any Location Etc Complete All As Directed. Etc Complete All As Directed. 107 Supplying , Laying & Testing In Replacement Cablexlpe Insulatedscreenedpvc Bedded Armoured With Galvanised Steel Wire Or Tape, Electric Power Cable Heavy Duty 1100 Volt Gradealuminium Conductor Of Size25x 4Coreincluding Taking Out Acsr / Ug Cable From Any Location Etc Complete All As Directed. Etc Complete All As Directed. 108 Supplying , Laying & Testing In Replacement Cablexlpe Insulatedscreenedpvc Bedded Armoured With Galvanised Steel Wire Or Tape, Electric Power Cable Heavy Duty 1100 Volt Gradealuminium Conductor Of Size16 X 4 Coreincluding Taking Out Acsr / Ug Cable From Any Location Etc Complete All As Directed. Etc Complete All As Directed. 109 Excavationin Trenches In Any Type Of Soil Not Exe 1.5 Mtrs Wideand Not Exe 1.5 Mtr In Depth For Laying Of Pipe / Cables Etc And Getting Out Incl Forming Bottom Surface To The Required Level / Slope Etc Complete All As Specified And Directed . 110 M&L For Dry Clean Sand Free From Sharp Materialsfor Cushioning Laid In Trenches In Layers Forunder Ground Electric Cablecomplete All As Specified And Directed 111 Supplying And Laying Precast Concrete Cable Cover Class Lv Type -I Flat Size 250X150x40 Mm Laid Parpendicular To The Axis Of Cable In Trenches Etc Complete As Directed. 112 Supplying And Laying Gi Pipe 50 Mm Bore Medium Grade Including Providing Fittings Such As Elbow, Tee, Socket Etclaid On Floors / Trenches / Walls With Complete Fixing Arrangements And Testing Etccompleteall As Specified And Directed . 113 M&L For Earthing Completewith Galvanisedsteelearth Plateelectrode Of Size 600 Mm X 600 Mm X 6 Mm Thick Weight N Less Than 17.25 Kgs Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Mtr Deep Below Normal Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Mtr Below Ground Level, Connected To Galvanized Earth Lead Wire 4.00 Mm Dia By Means Of Bolts Nuts Check Nuts & Washers Of Galvanized Iron Or Steel , Procteded By Gi Pipe 15 Mm Bore ( Light Grade ) And Watering Pipe 20 Mm Bore Gi Pipe ( Light Grade ) Andchamber Of Pcc 1:4:8 Type D2 Using 40 Mm Graded Stone Aggregate And Coping Shall Be In Pcc 1:3:6 Type C1 Using 20Mm Graded Stone Agg.50 Mm Thick Cover Of Rcc 1:2:4 Type B1 Using 20 Mm Graded Stone Agg. Reinforced With 8 Mm Dia Ms Tor Bar @ 80 Mm C / C Both Ways Including Excvation And Earth Work And Removal Of Surplus Soil Complete All As Shown In Electrical Plate No 3 Of Ssr Pt I ( 2009 ) With Charcoal Dust And Saltcomplete And Earth Leadconnected To Earthing Test Point ( Up To Main Switches, Dbs ) Completeall As Specified &Testing On Completion. Note:- ( I ) Item Includes The Cost Of 7.5 Mtr Length Gi Pipe For Protection For Gi Earth Wire. ( Ii ) Item Rates Includes The Cost Of 7.5 Mtr Earth Lead Gi Earth Wire. ( Iii ) Pcc Pit Shall Be Provided At Least 500Mm Away From The Pit And Not On The Earth Pit Itself And The Extra Costof Additional Length Of Watering Pipe, Bends, Elbow Etc Shall Be Deemed Included In The Unit Rate. 114 M&L For Earthing Completewith Galvanisedsteelearth Plateelectrode Of Size 600 Mm X 600 Mm X 6 Mm Thick Weight N Less Than 17.25 Kgs Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Mtr Deep Below Normal Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Mtr Below Ground Level, Connected To Galvanized Earth Lead Strip Of Size 32X6 Mm Thick By Means Of Bolts Nuts Check Nuts & Washers Of Galvanized Iron Or Steel , Procteded By Gi Pipe 15 Mm Bore ( Light Grade ) And Watering Pipe 20 Mm Bore Gi Pipe ( Light Grade ) Andchamber Of Pcc 1:4:8 Type D2 Using 40 Mm Graded Stone Aggregate And Coping Shall Be In Pcc 1:3:6 Type C1 Using 20Mm Graded Stone Agg.50 Mm Thick Cover Of Rcc 1:2:4 Type B1 Using 20 Mm Graded Stone Agg. Reinforced With 8 Mm Dia Ms Tor Bar @ 80 Mm C / C Both Ways Including Excvation And Earth Work And Removal Of Surplus Soil Complete All As Shown In Electrical Plate No 3 Of Ssr Pt I ( 2009 ) With Charcoal Dust And Saltcomplete And Earth Leadconnected To Earthing Test Point ( Up To Main Switches, Dbs ) Completeall As Specified &Testing On Completion. Note:- ( I ) Item Includes The Cost Of 7.5 Mtr Length Gi Pipe For Protection For Gi Earth Wire. ( Ii ) Item Rates Includes The Cost Of 7.5 Mtr Earth Lead Gi Earth Wire. ( Iii ) Pcc Pit Shall Be Provided At Least 500Mm Away From The Pit And Not On The Earth Pit Itself And The Extra Costof Additional Length Of Watering Pipe, Bends, Elbow Etc Shall Be Deemed Included In The Unit Rate.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Jun-2022 Amendment Other 16-07-2022
2 12-Jul-2022 Amendment2 Other 16-07-2022
3 16-Jul-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-07-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 83950.0 /-
Tender Value
INR 41.96 Lakhs /-

BOQ Items

Name of Work: CERTAIN SANCTION WORKS (05 Nos) IN AGE BR-I AND AGE EMUNDER GE BABINA
Sl. No. Item Description
1Excavationin trenchesnot exe 1.5 mtrs wideand not exe 1.5 mtr in depth and getting outin any type of soiletc complete all as specified and directed .
2Excavation in post holes (or similar holes) each not exc 0.5 cum , getting out in any type of soilsandremoving surplus soil to a distance not exc 50m and as directed.
3Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil comlete all as specified and directed.
4Returning, filling in, including spreading, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and as directed.
5Removing excavated soils/material to a distance n exc 50M and deposited where directed at a level n. exc 1.5M above the starting point complete all as specified and as directed.
6M&L for moorum laid in layers n exc 15 cm thickness , spread ,levelled , rammed and watering as in floorsetc complete and all as specified
7M&L for hard core of broken boulders/stone of gauge n exc. 63 mm, deposited, spreading, leveling watering and well ramming to true surface in layers not exceeding 15 cm thick each layer complete all as specified and directed.
8Demolition of brick work/stone masonary built in cement mortar of nay description ,any position and anylocation and as direcetd
9M&L for brick work with Fly Ash bricks ( FASB)straight or curved on plan exc 6 M radius built in cement mortar (1 : 4)etccomplete all as specified and as directed.
10M&L for PCC 1:3:6 type C 2 using 40mm graded stone agg as in filling and mass concrete , Sub base/flooring complete all as specified and directed.
11M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregatesas in foundation filling etccomplete all as specified and directed.
12M&L for PCC 1:2:4 type B-2 using 40mm graded stone agg as in filling and mass concrete, sub base/flooring complete all as specified and directed.
13M & L for PCC work of flexural strength of 40 Kg/Sqcm using cement 400kg /cumas in pavement , floors & hard standing,laid in panels not exceeding 30 sqm each , panel shall be formed using mild steel members of adequate size and thichness to create 10 mm wide joints , surfaces ofconcrete finished even and fair to desire level etc complete all as specified and as directed. Note : (i) Cost of sample testing for design mixto ensure flexural strength 40 Kg /sqcm will be borne by the contractor . Min cement content shall be 400 kg/cum of concrete . In case cement required more than 400 kg shall deemed to be included in the quoted rate and nothing extra shall be admissible on this account . (ii) Joint shall be measured and paid seperately .
14M&L for filling of contraction joints 10 mm wide x 30 mm deep and tfilled with sealing compound Grade "A" etc complete as directed
15M & L for precast RCC1:1.5: 3 Type A-1 using 20 mm graded stone aggregate as in lintel upto 1.50 mtr span etc complete all as specified and as directed. Note : Reinforcement shallbe paid seperately
16S&F, 2nd class hard wood ( SAL ) as in scantling, wrought timber frame work as in members of trusses like rafter ,purlins etc similar etc complete and as directed. Note : The moisture and species test is manadatory prior to used timber and shall be got tested from Govt lab or from NIBL approved lab . No payment of timber shall be made unless got tested and test results thereof found satisfactory
17M&L for mild steel TMTbars8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hookingends and binding with and includingmild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed .Make : As specified in tender documents
18S&F mild steel work as in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 with and including one shop coat of zinc chrominium primer paint complete all as specified and as directed.
19S&F mild steel work as in Roof trusses ( framed ) trussed , purlins , crane gentries rails and fastenings and heavy brackets framing ( Beam,Tee,Angle, Channel or flat sections ) incl distance pieces ,cleats etc of 290gde - E-165 etc complete all as specified and as directed. Make : As specified in tender documents
20S &F mild steel hold flat iron 40x5 mm thick as in wind tie over roof including securing bolts including driling holes etc complete and as directed Make : As specified in tender documents
21S&F mild steel ( Plain) plates , square cut or notched (ordinary and counter sunk) forming holes of suitable dia if requiredand fixed to pipe by electric welding alround the neck of pipe etc complete and as directed.
22S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 10 cm length and 11 to 15 mm dia
23Dismantling of timber scantling 40 Sqcm and over in section fixed in any position as framed work complete all as specified and directed
24Taking out /Dismantlingof existing roof treatment of any description , any position over roof including taking out plain cement concrete of any description to the thckness as directedetc complete and including lowering down complete waste materials to the ground on a place where directed and includingremoval of the same to a distance exc 250 mtr but n exc 500 mtr as directed .Note : The cost of lowering down and removal deemed included in unit rtae quoted by the tenderer.
25M&L for cutting out cracks to V section in existing roof or terracing ,cleaning out ,wetting and sealed solidly with hot mixture of bitumen and dry sand in proportion of 1:1 by weight etccomplete and as directed.
26M&L for cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove sealed with cement mortar 1:3 complete and as directed.
27M&L for P.C.C 1:2:4 type B-1 using 20 mm graded stone aggregate as in padding laid to slope over roof and surface finished even and fairetccomplete all as specified and as directed. Note : The thickness of PCC shall not be exceeded more than75 mm at any place
28M&L for P.C.C 1:2:4 type B-0 using 12.5 mm graded stone aggregate as incoping andon roof etccomplete all as specified and as directed.
29Supply only water roofing compound ( Liquid ) ISI marked etc complete and as directed
30M&L for 10 mm thick rendering in cement mortar 1:4 on concretesurfaces of roof when concrete is stillgreen mixed withwater proofing compound ( Liquid) @ 200 ml perbag of cement of 50 kgs ,surface finished even and fair enough to receive water proofing traetment etc complete all as specified and as directed. Note : WPC shall be measured and paid seperately
31M&L for providingwater proofing treatment over roof by applying the following operations :-(a) Preparation of plastered surface by cleaningwith water and leave the sufaces till to become surface total dry . (b) Applyingfirst coat of bitumen primer conforming to IS-3384 @ 0.4Kg / Sqm on plastered surface (c)Applying APP based polymeric membrane 3mm thick (Minimum thickness) and weightnot less than 3kg/Sqm ,reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) over on primed surfacelaid with 100mm side lap/end lap on prepared surfaces as per manufacturers instructions and under strict supervision of manufacturer"s tenchnical representativeetc and applying two coats of bituminous based aluminum paint @ 100 ml/sqm each coat etc complete and as directed. Note : Testing of APP membrane is mandatory and contractor will not be allowed to carry out the work untill results are obtained and found satisfactory .Cost of testing and samples ( 3Nos) deemed to be included in unit rate quoted by thetendrer and nothing extra on this account will be admissible .(ii) The cost of casting onecement plate of size 600 mm x 450 mm , 10 mm thick rendering in CM 1:3 in each building incl writing materials shall deemed to be included in the unit rate quoted by the tenderer.
32M &L for Plain concrete cement tiles (Cement) 30cm X 30cm x 25mm set and jointed and pointedin neat cement slurry on roof over & including 15mm thick screed bed in CM (1: 4) and joint between the tiles to be filled with chemiucal like Grout etc Complete all as specified and directed.
33Dismantling wall /ceiling boards of any description any thickness incl exiting snap grid framework of any descriptionand as directed.
34M&L for snap grid ( 600 x600 mm ) ceiling using aluminium anodised sectionsie Main Tee section of 36.5x25x1.4mm size (wt not less than 0.24Kg/RM) , Wall angle of size 40x25x2mm size (wt not less than 0.36Kg/RM) , Cross Tee section 23.5x26.4x1.4mm size (wt not less than 0.191Kg/RM) andSnap grid shall be fixed to ceiling by supporting hangers consisting of 6 mm dia mild steel bar made to shape including providing mild steel flat iron cleat with 40x3 mm and fixed with expansion dash fastener n exc 1.20 mtr both ways fixed to roof etccomplete all as directed.
35M&L for for 4 mm thick high pressure steam cured non asbestos fiber cement designer board of size 600mm x 600mm as in ceiling complete all as specified and directed with and including aluminium anodised snap grid frame.
36Dismantling asbestos cement , galvalume , fibre sheet ( Plain , corrugated , semi corrugated ) and as direcetd
37S&F Pre painted Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thickcolouredhaving tensile strength of 550 Mpa as in roof covering andfixed with self tapping screws and as directed .
38S&F Pre painted Galvalume aluminium zinc coating GI basedplain steel sheet 0.50mm thickcolouredhaving tensile strength of 550 Mpa as in cladding / wall fixed with self tapping screws and as directed .
39M&L for 75 mm thick P.C.C 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection laid in alternate panels made of 10 mm thick plywood( Size of each panel shall not exceed 12 Sqm )and finish the surface even and smooth withoutusing extra cement including filling of jointwith bitumen mastic ( 1 part bitumen mixed with 3 part dry sand) etc complete all as specified and as directed. Note : Cost of form work for forming joints and jointing materials deemed to be included in unit rate quoted by the tenderer.
40M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square / rectengular)DARK ( Premium Quality ) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurryand pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:6 etccomplete all as specied and directed.
41M&L glazed ceramic coloured tilesDARK ( Premium Quality ) 7 to 8 mm thick size 300x600 mm JOINT FREE over 15 mm thick rendering in cement mortar 1:4 in skirting/dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile etc complete all as specified and directed .
42Taking down cement plaster of any description built in cement mortar on brick or stone walls etc including racking out joints, hacking for Key, scrubbingdown with water etc.complete all as specified.
43M & L for 15 mm thick rendering in cement mortar 1: 6 on fair faces of brick work or concrete surfaces , surface finished even and smoothwithout using extra cement complete all as specified and as directed.
44M & L for 15 mm thick rendering in cement mortar 1: 6 on other than fair faces of brick work or stone masonary , surface finished even and smoothwithout using extra cement complete all as specified and as directed.
45M & L for prepration of newly plastered surfaces of walls appying two coat of cement base paint over a coat of primeretc complete all as specified and as directed .
46M & L for complete removal of existing treatment from walls and appying two coat of cement base paint over a coat of alkali resistant primerincluding necessary prepration of surface complete all as specified and as directed.
47M & L for applying two coat of white wash on wallsincludingnecessary preparation ofsurfaces all as specified and directed.
48M&L for Preparation of old decorated surfaces of wall including cornices,plastered or unplastered surfaces by brooming down or steel wire brushing to remove dust, dirt and loose scales of lime wash and other foreign material etc and applying two coat of white wash complete all as specifiedand directed.
49M&L for preparing new surfaces of steel of any description, over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paints over one coat of red oxide primer all as specified.
50S&F 100 mm bore Cast iron soil waste and vent pipe SPUN PIPEin any length with or without ear and jointed in CM 1:1 fixed to wallswith MS clamp made of flat iron 50x5 mm and bolt grouted in wall withPCC 1:2:4 type B-0 using 12.5 mm graded stone aggregates and taking out existing pipe of any description etc complete all asspecified and directed.
51S&F Cast iron bend any radius 100 mm bore etc compete and as directed
52Taking up or down existing steel tubing and connections including cleaning for refixing etc complete all as specified and as directed for 15 mm bore
53Taking up or down existing steel tubing and connections including cleaning for refixing etc complete all as specified and as directed for 20 mm bore
54Supplying, fixing, jointing and testing 15 mm dia galvanised iron tubing medium grade ISI Marked with all fitting such as bends, elbow, socket, reducer etc and fixed to wall or laid in floor complete all as specified and as directed
55Supplying, fixing, jointing and testing 20 mm dia galvanised iron tubing medium grade ISI Marked with all fitting such as bends, elbow, socket, reducer etc and fixed to wall or laid in floor complete all as specified and as directed
56Taking down old existing unserviceable tank PVC ( HDPE)and of capacity exc250 ltrs but n exc 500ltrs complete as direcetd
57S&F 500 ltr capacity or rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) WHITE , ISI marked , Triple layered construction hoisted and fixed in position including S&F 20mm dia GI pipe medium grade washout pipe 450mm long with plug and 20mm dia GI pipe medium grade overflow pipe 600mm long with fitting etc complete all as specified in SSR Part -I 2009 complete all as specified and as directed.
58S & Fball valve highpressure of PTMT with epoxy coated aluminium rod & highdensityplastic ball screwed for iron pipe 20 mm dia and fixed in new tank (minimum weight 20mm 210 gm) complete all as specified.
59S & F in repairs ball valve highpressure of PTMT with epoxy coated aluminium rod & highdensityplastic ball screwed for iron pipe 20 mm dia and fixed in new tank (minimum weight 20mm 210 gm) complete all as specified.
60S&F20 mm gun metal gate valve ( ISI Marked ) with iron wheel head screwed both ends for iron pipe etc complete as directed.
61S&Fin repair 20 mm gun metal gate valve ( ISI Marked ) with iron wheel head screwed both ends for iron pipe etc complete as directed.
62Demolition of cement concrete (unreinforced) inground floors and paving n. exc 15 cm thickness below or above ground level complete all as specified and as directed.
63Taking down carefully aluminium/copper point wiring on battenor in PVC conduit or in MS conduit with GI earth wire etc (for light, fan, socket or power point ) complete , including taking out fixtures and fittings such as switches , ceiling roses, pendents, regulators ,sockets,light fitting etcremoving materials to store for keeping in safe custudy or for taking credit ( as per schedule of credit for dismantled/taken out items ) and making goodthe disturbedsurfaces of walls, floors, ceilings etc and as directed .
64Taking down carefullyexisting wooden board , Main switch, MCB DB boxes, TPN boxes, cut out, etc of any size anycapacity fromboards completeall as specified and as directed.
65Taking down carefully sub main wiring with any cable / service connection twin core from wall / LT pole of any size of Aluminum with wooden batten and or through rigid conduit including GI wire and making good the disturbed surfaces of walls, roofs, floors etc complete all as specified and as directed.
66M & L for Surfacepoint wiring(INPVC CONDUIT ) one light pointcontrolled by one switch with PVC insulated and unsheathed flame retardant Low Smoke(FRLS) cable of 1.5 Sqmm (nominal area) with stranded copper conductor single core 1100 volts grade in and including non metelic rigid PVC conduit not less than 19 mm dia, clip, withMS terminal boxes (not less than 1.6mm thick) including earth dollywithframe plates with matching cover plates all modules including 1.5 Sqmmstranded copper conductor Green as continuous earth wire with lugs complete all as specified and as directed . Note : Quoted rates shalldeemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thickISI marked hylam sheet/ backlite sheet cover fixed with suitable brass screws and cup washers.
67All as per Srl item No. 66 above but one fan /Exhaust point controlled by oneswitch ®ulator.
68All as per Srl item No.66 above but one 3/5 pin5 Amp socket outlet point controlled by oneswitch on independent board.
69All as per Srl item No.66 above but one 3/5 pin5 Amp socket outlet point controlled by oneswitch on same board.
70Description all as per item No 66above but for power point wiring using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant Low Smoke(FRLS) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and including 1.5 Sqmmstranded copper conductor Green as continuous earth wire with lugs complete all as specified and as directed.
71M & L for CONCEALEDpoint wiringone light pointcontrolled by one switch with PVC insulated and unsheathed flame retardant Low Smoke(FRLS) cable of 1.5 Sqmm (nominal area) with stranded copper conductor single core 1100 volts grade in and including non metelic rigid PVC conduit not less than 19 mm dia, clip, withMS terminal boxes (not less than 1.6mm thick) including earth dollywithframe plates with matching cover plates all modules including 1.5 Sqmmstranded copper conductor Green as continuous earth wire with lugs complete all as specified and as directed .NOTE :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the conduit to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface PVC conduit/ casing & caping of suitable size as directed fixed on ceiling surface with using PVC rawl plugs. (ii)Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A". (iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thickISI marked hylam sheet/ backlite sheet cover fixed with suitable brass screws and cup washers
72All as per Srl item No. 71 above but one fan point controlledby oneswitch ®ulator.
73All as per Srl item No.71 above but one 3/5 pin5 Amp socket outlet point controlled by oneswitch on independent board.
74All as per Srl item No.71 above but one 3/5 pin5 Amp socket outlet point controlled by oneswitch on same board.
75Description all as per item No 71above but for power point wiring using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant Low Smoke(FRLS) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and including 1.5 Sqmmstranded copper conductor Green as continuous earth wire with lugs complete all as specified and as directed.
76S & F switch piano flush button type10 Amp, single pole ,one way , AC ,230 Volts , 50 Hz complete all as specified and asdirected.
77S&Fsocket outlet 2in 1 , 3 pin , 10 Amp , AC , 230 Volts , 50 Hzcomplete all as specified and asdirected.
78S & F switch piano flush button type 20 Amp, single pole, one way ,AC ,230 Volts ,50 Hz complete all as specified and asdirected.
79S & Fsocket outlet 2 in 1, 10 Amp and 20 Amp, AC , 230 Volts ,50 Hz complete all as specified and asdirected.
80S & Fdelux fanRegulator rotary, step type , AC ,240 Volts ,50 Hz complete all as specified as directed.
81S & FLamp holder,PVC/Urea type with back plate ,AC ,230 Volts ,50 Hz , ISI marked suitable for batten fittingscomplete all as specified as directed
82S&F ceiling rose,surface bakelite 65 x50mm three brass terminals, AC ,230 Volts ,50 Hz ISI marked completeall as specified and asdirected.
83S & F9/10W LED retrofit Ball lamp holder base B-22, bipin type AC 230 Volts 50 Hz with PF not less than 0.95 with polycorbonate body and aluminium heat sink complete all as specified as directed.
84S&F for sub main wiring with PVC insulated, unsheathedflame retardant Low Smoke(FRLS) 2 single core cable 1100 volts grade withcopperconductor of size 10 sq mm (Nominal area) multi stranded drawn into new non rigid metellic PVC conduit with and including 6 sqmm green stranded copper conductor as contineous earthwire withlugs complete all as specified and as directed. Note:Two run of single core PVC cable with one run of earth conductor cable and conduit shall be measured as one unit. (ii)Cost of new PVC conduit including conduit accossoriesshall be deemed to be included in unit rate quoted by the tenderer .
85S&F for sub main wiring with PVC insulated, unsheathedflame retardant Low Smoke(FRLS) 2 single core cable 1100 volts grade withcopperconductor of size 6 sq mm (Nominal area) multi stranded drawn into new non rigid metellic PVC conduitwith and including 4 sqmm green stranded copper conductor as contineous earthwire withlugs complete all as specified and as directed. Note:Two run of single core PVC cable with one run of earth conductor cable and conduit shall be measured as one unit. (ii)Cost of new PVC conduit including conduit accossoriesshall be deemed to be included in unit rate quoted by the tenderer .
86S&F TPN DB- DPX 125 MCCB DBs 4 way double door with provision for DPX 125 MCCB and as incomer and SP/TP MCBs as out going no of modules DPX 125 + 12 etc complete all as specified and directed.
87S&F MCCB , 200Amps, 415 Volts, 4 P , 50HZ, having 36 KA rupturing capacitywith electronic trip arrangment and setting screw upto 70% including making connection with excisting cable with connection and materials like copper strips,lugs,nut & bolts etc. complete all as specified and as directed .
88S&F MCCB , 100Amps, 415 Volts, 4 P , 50HZ, having 25 KA rupturing capacitywith electronic trip arrangment and setting screw upto 70% including making connection with excisting cable with connection and materials like copper strips,lugs,nut & bolts etc. complete all as specified and as directed .
89S&F MCCB , 63Amps,415volts,3 phase,50HZ, having 35 KA rupturing capacity, 415 volts with electronic trip arrangment and setting screw upto 70% including making connection with excisting cable with connection and materials like copper strips,lugs,nut & bolts etc. complete all as specified and as directed .
90S&F MCCB , 63Amps,415volts,3 phase,50HZ, having 16 KA rupturing capacity, 415 volts with electronic trip arrangment and setting screw upto 70% including making connection with excisting cable with connection and materials like copper strips,lugs,nut & bolts etc. complete all as specified and as directed .
91S&F sheet metal enclosure box with hinges door suitable for MCCB 63 Amp to 100 Amp with all necessary fixing arrangementetc for walletc. complete all as specified and as directed .
92S&Fsheet metal enclosure double door concealed suitable for distribution boards when MCBs to be used having 100Amp rated bus bar 8 ways 240 V complete all as specified and as directed.
93S&FMCB single pole and neutral 40 Amp 240 V ,10KA , "C" series, ISI marked complete all as specified and as directed with copper lugs.
94S&FMCB single pole and neutral 63 Amp 240 V ,10KA , " C" series, ISI marked complete all as specified and as directed with copper lugs.
95S&FMCB TPN 63 Amp 240 V ,10KA , "Cseries, ISI marked complete all as specified and as directed with copper lugs.
96S&FMCB single pole 6 to 32Amps 240 V,10KA, "C" series,ISI markedcomplete all as specified and as directed with copper lugs.
97S&Fin repairs 20 W LED,6000k decorative ultra slim linear fitting , extruded aluminium , environmental friendly, energy efficient incl 20 W lamp fitted incl wiring upto and terminating into existing ceiling rose complete all as specified and as directed.
98S&F 36W 2X2 LED fitting Ultra mordern ceiling mounted luminaire suitable for armstrong/ grid ceiling in MS housing with high brightness LEDs incl wiring upto and terminating into existing ceiling rose.
99S&F wall mountedfan 600 mm sweep TURBO FORCE aerodynamic desined blade for high air deleivery complete incl all necessary fixing arrangements and as directed.
100S&F ceiling fan 1200mm sweep BEE ratedAC single phase 230 volts etc connecting with flexible cable 3 core copper conductor of size 23.0/0076 of suitable length from celling rose complete all necessary arrangement of hanging of celling fan (GI Pipe hook etc) as specified and as directed.
101S & F Exhaust fan,AC , singe phase , 230/240 Volts , 300 mm sweep ,noiseless light-weight rust proof steel body self closing louvers and blades, speed1400complete with all arrangement of making hole complete all as specified and as directed.
102S&F for replacement & testing commissioning of outdoor type bus bar panel padestel type weather proofMS cubical panelboard made of3 mm CRCA MS sheet ,size 110 cm x 80 cm x 40 cm, 4 Nos of aluminium bus bar of 500 Amp capacity including providing MCCB ,4 pole ,320 Amp , repturing capacity35 KA , adjustable type (Ics =Icu=100%) including one coat of redoxide and two coat of enamel paint powder coated, mounted on mild steel channel of suitable sizeand providing PCC work inPCC1:3:6 type C-2,60 CM height above GL over 300 mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels & aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed.
103S&Fnew generation energy saving and environmental friendly long life LED flood light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 30 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) completeall as specified and directed.
104S&F in replacement new generation security light fitting 1 X 36 W LED , envoirnmental friendly long life , made up of of innovative die cast aluminium housingwith high power LED as light source withIP 66 protection , power consumption 45 watt complete input voltage of 150 -240 Volt ( nominal rated voltage 240 volt) includingelectric connection with1.5 sqmm 3 core PVC insulated and PVC sheathed cable stranded Copper conductor from junction box to security light etc complete as specifiedand as directed.
105Supplying , laying & testing in replacement cableXLPE insulatedscreenedPVC bedded armoured with galvanised steel wire or tape,electric power cable heavy duty 1100 volt gradealuminium conductor of size 50x3.5Coreincluding taking out ACSR/UG cable from any location etc complete all as directed. etc complete all as directed.
106Supplying , laying & testing in replacement cableXLPE insulatedscreenedPVC bedded armoured with galvanised steel wire or tape,electric power cable heavy duty 1100 volt gradealuminium conductor of size25x3.5Coreincluding taking out ACSR/UG cable from any location etc complete all as directed. etc complete all as directed.
107Supplying , laying & testing in replacement cableXLPE insulatedscreenedPVC bedded armoured with galvanised steel wire or tape,electric power cable heavy duty 1100 volt gradealuminium conductor of size25x 4Coreincluding taking out ACSR/UG cable from any location etc complete all as directed. etc complete all as directed.
108Supplying , laying & testing in replacement cableXLPE insulatedscreenedPVC bedded armoured with galvanised steel wire or tape,electric power cable heavy duty 1100 volt gradealuminium conductor of size16 x 4 Coreincluding taking out ACSR/UG cable from any location etc complete all as directed. etc complete all as directed.
109Excavationin trenches in any type of soil not exe 1.5 mtrs wideand not exe 1.5 mtr in depth for laying of pipe/cables etc and getting out incl forming bottom surface to the required level/slope etc complete all as specified and directed .
110M&L for dry clean sand free from sharp materialsfor cushioning laid in trenches in layers forunder ground electric cablecomplete all as specified and directed
111Supplying and laying precast concrete cable cover class LV type -I flat size 250x150x40 mm laid parpendicular to the axis of cable in trenches etc complete as directed.
112Supplying and laying GI pipe 50 mm bore medium grade including providing fittings such as elbow, Tee, socket etclaid on floors/trenches/walls with complete fixing arrangements and testing etccompleteall as specified and directed .
113M&L for earthing completewith galvanisedsteelearth plateelectrode of size 600 mm x 600 mm x 6 mm thick weight n less than 17.25 kgs buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade)and watering pipe 20 mm bore GI pipe(light grade) andchamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg.50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT I ( 2009)with charcoal dust and saltcomplete and earth leadconnected to earthing test point (up to main switches, DBs) completeall as specified &testing on completion. NOTE:-(I)item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii)PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra costof additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
114M&L for earthing completewith galvanisedsteelearth plateelectrode of size 600 mm x 600 mm x 6 mm thick weight n less than 17.25 kgs buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead strip of size 32x6 mm thick by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade)and watering pipe 20 mm bore GI pipe(light grade) andchamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg.50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT I ( 2009)with charcoal dust and saltcomplete and earth leadconnected to earthing test point (up to main switches, DBs) completeall as specified &testing on completion. NOTE:-(I)item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii)PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra costof additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail