Rural Development Government Departments Closing in 0 days TDR #32848750

Retrofitting Of Water Supply Scheme At Borkhadi Pingle Borkhadi Tanda Tq. Sengaon Dist. Hingoli Under Jal Jeevan Mission ( Jjm )

Issued by Government Departments · tanda, Maharashtra
Tender Value
1.12 Crore
Estimated cost
Bid Submission
11 Jul 2022
0 days left
EMD
1.12 Lakhs
Bank guarantee accepted
Document Fee
5600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tanda → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Retrofitting Of Water Supply Scheme At Borkhadi Pingle Borkhadi Tanda Tq. Sengaon Dist. Hingoli Under Jal Jeevan Mission ( Jjm )

BOQ

Name of Work Retrofitting ofWater Supply Scheme atBorkhadi Pingle Borkhadi Tanda Tq. Sengaon Dist. HINGOLI
Sl. No. Item Description
1BORKHADI PINGLE- well deepeningITEM NO. 1 Horizontal Bore well 30 m length 4 No.sTaking surface bore well of 115 mm dia and 30M of depth (as per GSDA certificate)GSDA DSR 21-22 P NO.1l No. A1
2ITEM NO. 2 Excavationin generalinhard material comprisingofsoftrock,hardrock,Manjara rock,etc,byblasting/controlledblasting,chisellingasrequiredinwetordry condition for Head Works i.e. Intake Well, Connecting Pipe, Jack Well, Pump House, supply Well, etc. for lift 0 to 1.5 M and lead of 150 M including baricading, guarding, disposingoffsurplusexcavatedstuffwithinaradiusof0.5km.asdirectedby Engineer-in-charge, excluding refillingLift 10.5 to 12 M
3Lift 12 to 13.5 M
4Lift 13.5 to 15 M
5Lift 15 to 16.5 M
6Lift 16.5 to 18 M
7ITEM NO.3 Dewateringtheexcavatedtrenchesandpoolsofwaterinthe buildingtrenches/ pipeline trenches,well works by using pumps and other devices including disposing offwatertosafedistanceasdirectedbyEngineer-in-charge(includingcostof machinery, labour, fuel), etc. complete.10 BHP pumps daily 8 hrs for 45 days MJP SSR 2021-22 Item No. 6.a PG. No. 229
8ITEM NO.4 Carrying out recuperation/ yield test for asserting the discharge of constructed well/ excavated profile as directed by Engineer-incharge. The test is carried out by drawing down water from the well/profile below normal/ subsoil water level upto full depth rise in water level is recorded. The normal water level/ subsoil water level in the well/ profile as well as stainer/ suction level at pump as per design of W.S. scheme shall be recorded prior to the test including cost of all materials, overhead, labourers, etc. completed as directed.Lps less than 25,000 MJP SSR 2021-22 Item No. 17PG. No. 231
9PUMPING MACHINARY 3 BHP ITEM NO. 1 Providing, erecting and giving tests of submersible pump set confirming to IS 8034 and motor confirming to IS 9283, with water proof winding and discharge with stainless steel shaft. Mortar suitable for working on 415 V = 10% 3 phase 50 Hz A.C. supply with cable guard, thrush carbon/fible bearing to withstand entire hydraulic thrust with suitable suction strainer, pump should have suitable discharge outlet as per manufacture\"s design. Antithrust streamlined run and 2 pairs of erection clamps 80 mm width non return valve.Submersible pump 150 mm dia (with bronze impeller upto 8 stages).Submersible pump 150 mm dia (with bronze/ Stainless steel (CF8M) Impeller upto 8 stages).3 BHP suitable for 48 mtr head & 3357 litres/hr discharge. (MJP MECH SSR 21-22 P.NO.1 PM 1-2-3)
10ITEM NO. 2Providing and Fixing L.T. skeleton panel board upto 5 HP. (As per detail sheet attached)
11ITEM NO. 3Supplying and erecting flat flexible 3 core 2.5 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.(PWD Elect. CSR 2021-22 P. No. 218 I. No. 12-4-9)
12ITEM NO. 4 Providing & erecting ISI mark G.I. pipeof followingclassanddia. including all local and central taxes, octroi, inspection charges, transportation to stores, etc. complete 65 mm dia (heavy) on well(MJP CSR 2021-22 P. No. 82 l. No. 1.III.1.c.vii)
13ITEM NO. 5 Providing, supplying and fixing ISI mark CI D/F Reflux valve (non-return valves of following dia including all taxes (central and local), railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental store/site, unloading, stacking etc. complete. Reflux valves as per I.S. 5312 part I (1984)a) Without bypass arrangement - PN - 1a) Without bypass arrangement - PN - 1 80mm dia(MJP CSR 2021-22 P. No. 131 l. No. 1 a). v)
14ITEM NO. 6 Providing and fixing double flanged sluice valve confirming for IS-2096/14846 including worn gear arrangements as per test pressure stainles steel spindle, caps including all taxes transportation etc completea) Sluice valve - PN - 1(Without bypass).80 mm dia(MJP CSR 2021-22 P. No.132l. No. 2Aiii)
15ITEM NO. 7 Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)a) Sluice valve - PN - 1(Without bypass)80mm dia(MJP CSR 2021-22 P. No.135l. No. 4 v)
16ITEM NO. 8 Providing and erecting pressure gauge of required capacity complete with syphon tube, isolating cock suitable for 12mm dia GI pipe. Pressure gauge shall be installed as directed, with tapping on rising main pressure gauge (100 mm dia)(MJP Mech. CSR 2021-22 P. No.7 PM11-1)
17ITEM NO. 9 Providing earthing with galvanized iron earth plate size 60 x60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP.Plate type Electrode (IS 3043)1. For pump - 2 Nos1. For panel board- 1No.(PWD Elec. CSR 2021-22 Item No. 9-1-3)
18ITEM NO. 10 Providing and supplying ISI standard CI Flanged/ S&S specials including all taxes (Central and local), railway freight, insurance, unloading from railway wagon, loading into truck transport to departmental store/site, unloading stacking etc. complete.CI D/F specialsi) 80 to 300 mm dia(MJP CSR 2021-22 Section-I(I) P. No. 72 l. No. 6ai)
19Rising Main ITEM NO.1 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipessuitable for potable water with solvent cementjoints including cost of couplers, as per ISspecification no. 4985 / 1988 excluding GSTlevied by GOI and GOM in all respect, includingtransportation, freight charges, inspectioncharges, loading, unloading, conveyance to thedepartmental stores and stacking the same inclosed shed duly protected from sun rays andrains including cost of jointing material i.e.solvent cement, etc. complete (selffit type to bejointed with cement solvent). Proposed Junction to Pr ESR (110 mm PVC 6 Kg/cm2)
20Providing and supplying ISI standard pvc specials & fittings including transportation to stores/ site,loading,unloadingchargesexcludingGSTleviedby GOI & GOM,etc. complete.10% cost of pipes MJP SSR Section I (II) Page No. 76
21ITEM NO. 2Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints Including all taxes (Central and local) ,InspectionRCC PIPES NP III200 mm dia RCC NP III PIPES(MJP SSR 2021-22 P No.97 section I (V) 1. e iii)
221% cost of pipes MJP SSR 2021-22 Section I (e) Page No. 97
23Item No.3 Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.Reflux valves as per I.S.5312 Part I (1984)a) Reflux valves - PN -1 Without byepassarrangement 100 mm Dia Reflex Valve (MJP SSR 2021-22 P. No 131 I.No 1a iii to viii)
24Item No.4 Providing and supplying Air Valves as per IS- 14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in all respect etc. complete. a) Air valve Single ball Flanged - PN -1 40 mm dia (MJP SSR 2021-22 P. No 136 sec. I (XII) 5. a) iv)
25Mechanical Tee 100x100x100 mm (MJP SSR 2021-22 P. No 148 I.No 8/a/1)
26ITEM NO. 5 Labour Section Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift 0 to 1.5MJP DSR 2021-22 SECTION- E Sr.No.1 pg.no.42
27ITEM NO.6 Excavationfor foundation/ pipe trenchesin hard murumand boulders,W.B.M. road includingremovingthe excavatedmaterialupto a distanceof 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatreing, preparing the bed for foundation and excluding backfilling, etc. complete.. Lift 0 to 1.5 MMJP DSR 2021-22 SECTION- E Sr.No.2 pg.no.42
28ITEM NO.7 Excavationfor foundation/ pipe trenchesin soft rock&old cement& lime masonary foundation,asphaIt raod includingremoving the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift 0 to 1.5 M MJP DSR 2021-22 SECTION- E Sr.No.5 pg.no.42
29ITEM NO.8 Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts a below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by allmeans. (Bd-A-6/259) Lift 0 to 1.5 MMJP SSR 2021-22 SECTION- E Sr.No.2 pg.no.42
30ITEM NO.9 Filling inplinth floors murum bedding intrenches with approved murum from excavatedmaterialsfromfoundation15to20cmlayersincludingwateringand compaction complete.Murum selected from excavated stuff MJP DSR 2021-22 SECTION- E Sr.No.16 pg.no.45
31ITEM NO. 10 Lowering Laying and jointing with P.V.C pipes and specials of following class and diameter including cost of conveyance from source to site of works including cost of all labour,material,except cement solvent,rubber ring,as per IS code etc.complete (with cement solvent joint/ring fit joint). 110 mm diaMJP SSR Section I (II) Page No. 80
32ITEM NO. 11 Hydraulic testing of PVC pipe line to specified pressure includingcost of all materials and labour and water for testing for specified length including cutting, placing end cap makingarrangement forfillingsafewaterusingreciprocatingtypepumpswhich shouldbeabletoprovidespecified testpressuregaugesandothernecessary equipments,labour,operationcharges,etc. requiredfor testing.The rate underthis itemshallalsoincludecostofretesting,ifnecessaryandreinstatingtooriginal position Working pressure 6 kg/cm2. 110 mm diaMJP SSR Section I (II) Page No. 81
33ITEM NO. 12 Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineerin- charge (For all class of pipes.) as per IS- 783-1985.200 mm RCC Class \"NP-III\" Pipe. (MJP SSR 2021-22 P No.98 section I (V) 2. iv)
34ITEM NO. 13 Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves ( Rate for all class of valves)Well to ESR 100 mm Dia For Sluice Valve (MJP SSR 2021-22 P No.135 I.No.4a) iii)
35ITEM NO. 14 Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete, 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M 150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve tee, etc. complete as per type design and as directed by Engineer -in- charge for following diameters of pipe lines (type design attached)Upto 150mm 40 mm dia
36ITEM NO. 15 Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion,precast RCC frame and cover, etc. Complete as directed by engineer-in-charge. Note: Wall thickness : 0.23 M for depth of .2 M and 0.35 M for balance depth exceeding 1.2 M. As above of 60x45 CM internal size and depth upto 0.9 M with precast R.C.C slab cover(MJP SSR 2021-22 P No.220 I.No.1a)
37ITEM NO. 16 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.(MJP SSR 2021-22 P No.45 I.No.15)
38Distribution System ITEM NO.1 Material. Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same inclosed shed duly protected from sun rays and rains including cost of jointing material i.e.solvent cement, etc. complete (self fit type to be jointed with cement solvent).MJP SSR 2021-22 Section I (II) Page No. 76 75 mm
3990 MM
40110MM
41140MM
42Providing and supplying ISI standard PVC & GI specials and fittings including transportation to stores/site, loading, unloading charges excluding GST levied by GOI & GOM, etc. complete.10% of cost of pipes
43ITEM NO.2 Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints Including all taxes (Central and local) ,Inspection RCC PIPES NP III Considering Nalla / Road Crossing200 mm dia RCC NP III PIPES
441% of cost of pipes
45ITEM NO.3 Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. complete.Without by pass arrangement - PN-1.MJP DSR 2021-22 SECTION- E Sr.No.2 pg.no.42. 65 mm sluice valve
4680 mm sluice valve
47100 mm sluice valve
48ITEM NO.4 LABOUR Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling,wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering,excluding backfilling, etc. complete by allmeans. (Bd-A-6/259)Lift 0 to 1.5MJP DSR 2021-22 Section E Sr.No.2 Pg. No.42
49ITEM NO.5 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation andexcluding backfilling, etc. complete. (Bd-A 1/259)Lift 0 to 1.5MJP DSR 2021-22 Section E Sr.No.2 Pg. No.42
50ITEM NO.6Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundationand excluding backfilling, etc. complete. (Bd A-2/259)Lift 0 to 1.5MJP DSR 2021-22 Section E Sr.No.2 Pg. No.42
51ITEM NO.7 Excavationfor foundation/ pipe trenchesin hard murumand boulders,W.B.M. road includingremovingthe excavatedmaterialupto a distanceof 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatreing, preparing the bed for foundation and excluding backfilling, etc. complete.Lift 0 to 1.5 MJP DSR 2021-22 Section E Sr.No.2 Pg. No.42
52ITEM NO.8 Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259 Lift 0 to 1.5MJP DSR 2021-22 Section E Sr.No.2 Pg. No.42
53ITEM NO.9 Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15cm to 20cm layers including watering and compaction complete.Murum selected from excavated stuffMJP DSR 2021-22 Section E Sr.No.16 Pg.No.45
54ITEM NO.10 Lowering Laying and jointing with P.V.C pipes and specials of following class and9 diameter including cost of conveyance from source to site of works including cost of all labour,material,except cement solvent,rubber ring,as per IS code etc.complete (with cement solvent joint/ring fit joint) Working Pressure 4 kg/cm2MJP DSR 2021-22 Section I(II) Sr.No.4 Pg. No.80 75 mm
5590 mm
56110 mm
57140 mm
58ITEM NO.11 Hydraulic testing of PVC pipe line tospecified pressure including cost of allmaterials and labour and water for testing forspecified length including cutting, placing endcap making arrangement for filling safe waterusing reciprocating type pumps which shouldbe able to provide specified test pressuregauges and other necessary equipments,labour, operation charges, etc. required fortesting. The rate under this item shall alsoinclude cost of retesting, if necessary andreinstating to original position. MJP SSR Section I(II) Pg. no. 80 Working Pressure 4 kg/cm2 75 mm
5990 mm
60110 mm
61140 mm
62ITEM NO.12 Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineerin- charge (For all class of pipes.) as per IS- 783-1985.Considering Nalla / Road Crossing. 200 mm RCC Class \"NP-III\" Pipe.MJP SSR 2021-22 Section 2 Page No. 98
63ITEM NO.13 Lowering, laying, jointing in positionfollowing CI/DF Reflux, butterfly valves and sluice valves including cost of all labors jointing material including nutbolts and giving satisfactory hydraulic testing etc complete ( Rates for all class of valves ) MJP DSR 2021-22 Item No. 4a Sec. I (XII)pg.no.135 65 mm sluice valve
6480 mm sluice valve
65100 mm sluice valve
66ITEM NO.14 Providing and fixing C.I. road box including loading, unloading and carting to site of work including all necessary excavation in all types of strata and fixing in murum packing, etc. complete. 100 mm x 225 mm (20 kg). MJP DSR 2021-22 Item No. 5a pg.no.223
67ITEM NO.15 Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)Spec. No. - Bd E /1 Page No. 287 and B-7, Page No. 38
68ITEM NO.15 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. Net volume of refilling. MJP DSR 2021-22 Item No. 16 Sec.E pg.no.45
69CHLORINATION ARRANGEMENT ITEM NO.1 Providing and installing simplegravityfeed disinfection arrangement with TCL powder solution on the percolation well / service reservoir including solution tankfeeding pipe, dosing arrangement all other accessories giving tgrialand test etc. complete. Drip Type Chlorinator 2 set
70TRIAL & RUN OF SCHEME ITEM NO.1 Commisioning running and maintaining the scheme to quantities, rate capacity, including manning necessory personnel such as operator, valveman, etc, as pr requirements of the scheme and who should also administer chemical dose for a period of one month for individual scheme together with training of personnel spared by MJP/ Local Body and handling over the scheme to Local Body after completion of the above period as directed by Engineer - in charge. For single village (1 Month) (M.J.P. SOR 21-22 P. No 232 I.No.1a)
71Fencing and M.S. gateFor Ex. Well ITEM NO.1 Providing & erecting chain link fencing 1.6 Mtr height with GI chain link of size 50*50 mm 8 SWG thick and fixed 75 mm above GL vertical M.S. angle of 40*40*6 mm size embedded in cc block 1 :4 :8 mix of size 450*450*670 mm at 1.75 m centre to centre wiyh iron bar 16 mm dia as a hold fast including welded link with angle frame at 30 cm cenre to centre nuts & bolts & horizontal MS angle at top & bottom of 25 * 25* 5 mm size & vertical MS flat 35 * 5 mm & 25 * 5 mm horizontal including cross supports of 40 *40*6 mm angle both sides at every corner in cc with 3 coat of oil painting etc complete. PWD SSR 2021-22 I.No 46.39 BDW P.No.217
72ITEM NO.2 Providing and fixing M.S. gate 2.5 Mwide for compound with 40 mm dia G.I.pipe, approved grill work, RCC M-150 sidepillars of 25 cm x 40 cm x 2.5 M height, itsfoundation, finishing, painting, etc.complete.MJP SSR Section-H: Miscellaneous P.No.58
73FHTC ITEM NO. 1 Providing and making UPVC/MDPE pipe consumer service connection on Distribution main by drilling hole with suitable means , including all labour , UPVC/MDPE Pipe of required length with or without Road crossing as described below, including cost of specials like Saddle/Clamp Saddle of suitable material, and diameter suitable for Distribution main, 15mm /20mm/ 25mm respective Dia Heavy duty Brass/Polyprophylyne(Twin Jacketed ) Ferrule , Male and Female thread adapter Elbow, Bends,couplers ,Tees, Clamps of suitable material and sundry materials as per requirment, including providing and fixing medium duty 15.mm brass bib tap, GI casing pipe of suitable diameter of 32mm/ 40mm/ 50mm respectively of required length for Road crossing, including requird labour for excavation in all types of strata up to the depth of 0.75m or as per site requirement,all types of plumbing fittings, refilling , Closing the water supply in that area, dewatering, hydraulic testing and restarting the water supply ,transportation of material etc. complete as directed by Engineer in A) Household Connection without water meter (Comression Saddle+ISI Mark Ferrul) for HDPE & PVC pipe For MDPE/UPVC Pipe Service Connection on Disribution main (With Road Crossing)For 15 mm Service connection
74Without Road Crossing)For 15 mm Service connection
75RCC ESR 80000 litres Staging Height 6 m. ITEM NO.1 Designing (aesthetically), and constructing RCC Elevated Service Reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 meters centre to centre for E.S.R. having capacity 500 m3 & not more than 6 m c/cfor E.S.R.having capacity above 500 m3 including excavation in all types of strata, foundation concret, cement plaster with water proofing compound to the inside face of the container including refilling disposing of the surplus stuff within a lead of 50 meters, all labour and material chargesincluding lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design. providing and fixing accessories such as Stainless steel ladder inside and M.S. ladder with G.I. railingoutside, C. I. manhole frame and covers water level indicatiors, lightening conductor, G. I. pipe railing around walk way and top slab, providing spiral staire case from ground level to roof level, M.S.Grill gate of 2 Mtrs height with locking arrangement, B.B. masonry chambers for all valves, ventilating shafts, providing and applying three coats of acrylic emulsion with silicon additives paint to the structure including roof slab and epoxy paint to internal surface & anti-termite treatment for underground parts of the structures and giving satisfactory water tightness test as per I.S. code, The job to include painting the name of the scheme and other details on the reservoir as per the directions of Engineer-in-charge.The design of the structure be in accordance with relevant I.S. specification (I.S. 3370 - 1965 or revised.) The design shall satisfy the stipulations as per I.S. 1893 - 1984 and I.S. 13920 / 1993 for seismic force and I.S. - 11682 / 1985 for R.C.C. staging of overhead tanks.For design having more than 6 columns, provision of internal bracing is obligatory.Externalbracingsisalso obligatory.The entire structure shall be in M-300 mix only.Plainroundmildsteelbarsgrade-I conformingtoI.S.432part-I or high yield strength deformed bars conformingtoI.S.1786orI.S.1139 shall be used, grade-II mild steel bars will not be allowed.Irrespective of the type of foundation proposed in the design, one set of bracing be provided at the ground level.These rates include providing M.S. ladder for E.S.R.s upto 2 lakh litres capacity and providing spiral staircase for E.S.R. above 2 lakh litres capacity.Staging shall have to be designed with stresses of M-200 concrete for ESR. Howeverall RCCconstructionshould be done in M-300.Theseratesare includingthe costof uplift pressure if any and entire dewatering during execution. In case of waterloggingareawherewateris stretch at shallow depth, extra provision of dewatering shall be made as per site condition.AllconditionsgivenintheMember Secretary\"sCircularNo. MJP/ TS-I/ 350 / 1668 dt. 2-8-97 and MJP / S-I / 350 / 2127 dt. 13-7-99 shall be strictly followed andadditional cost, if any, due to these conditionsis includedin the rates mentioned below.75%partrateshallbepayablefor reinforcementconcreteand plastering items of containers of E.S.R. till satisfactoryhydraulictesting for water tightnessisgiven;andtillthatwork shall be treated as incomplete.Theratesindicatedinthetableare excludingthecostofpipes,specials andvalvesrequiredforinlet,outlet, washout, overflow and bypass arrangement. The scope of work, however, includes costoferecting, laying and jointing of pipes and valves including cost of jointing materials upto 5Mbeyondouterfaceof outermost column.ForESRupto500cumcapacityC.I. double flanged pipes upto 300 mm dia shall be provided and C.I. specials shall beused.ForESRabove500cum capacityC.I./M.S.pipeassemblywith minimum 8 mm thickness upto 500 mm diaandminimum10mmthickness above 500 mm dia can be used with properanti-corrosiveepoxy treatment from inside and outside.Belowmentionedratesarefor foundations with individual footing with bearing capacity of20tonnes per squaremetre.Forraft foundations, these rates shall be increased by 7.5% where safe bearing capacity (SBC) is 5 MT per sqm and by 5% where SBC is morethan5 MT/sqmandupto10 MT/sqm.This%of5%or 7.5%is applicable for estimationof amount of lumpsumitem of ESR. For extra item due to change from individual foundationtoraft, actualincreasein concreteandsteelbepaidasper relevant DSR item.The rate shall be increased by 30% for bearing piles upto depth of 10 M and for further increased in depth by 5 M each, it shall be increasedby another10%. These rates are applicable where raft is not feasible. For pile foundations sulphate resistant cement shall only be used. Single pile for the column is not permitted, group of piles shall be designed with pile cap for each column of ESR.The rates are applicable for staging heightof 12 M. Theseratesshallbe increasedor decreasedfor per metre variation in this staging height as below:Following rates are for seismic zone III. For zone IV, these rates shall be increased by 5% and for zone II, these rates shall be decreased by 5%. Concerned Executive Engineer shall confirm the seismic zone for the scheme from seismic zones plan before estimation and adopt appropriate rates as per actual seismic zones. (Seismic maps attached in this CSR).RCC ESR Capacity 80000 litres 6 m staging Height, 3 m tank height. Total cost for 80000 Litres @ 6 m staging Height . 5% decrease for zone II(MJP SSR P No. 214 Section K (II)2.)
76ITEM NO.2 Providing & supplying ISI standard CI double flanged pipes excluding GST levied by GOI & GOM in all respect including railway freight, insurance , unloading from railway wagon, loading into truck transport to stores, unloading etc. complete as directed by Engineer-in-charge. (MJP SSR P No. 72 Section I(I)5.ii/iv) Inlet 100 mm dia CID/F pipes
77Outlet 100 mm dia. CI.D/F pipes
78125 mm dia. CI.D/F pipes
79Overflow 100 mm dia. CI.D./F pipes
80Washout 100 mm dia. CI.D/F pipes
81ITEM NO.3 Providing And supplying ISI standard CI Flanged /s &S Specials Including all Statutory Duties &taxes such as GST Levied by GOI &GOM in all Respect.Railway Freight Insurance Unloading From Railway wagon,Loading into truck Transport to Departmental Store /Site UnloadingStacking etc Complete D/F Specials 300 D/F Specials Upto and Including150 mm. 80 mm to 300 mm dia. ( M.J.P SOR 21-22P.NO 72 I.NO.6a)
82ITEM NO.4 Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. complete. Sluice valves PN-1 without bye-pass arrangement (MJP SSR P No. 132 Section I(XII) 2a.iv) 100 mm dia. Sluice valve - Outlet/Distribution
83125 mm dia. Sluice valve - Outlet/Distribution
84100 mm dia. Sluice valve - Inlet/Bypass
85100 mm dia. Sluice valve - Washout
86BORKHADI TANDA- Percolation WellItem No1Taking Core Bore of 115 mm dia Bore by helo of Drilling Rig, Machine etc. Complete as directed by Engineer in charge and upto the satisfaction of Engineer in charge. (Including all labours carting, loading, unloading etc) (GSDA DSR 2021 Pg. No. 9 Sr. No. E-1)
87Item No2Excavation in general in soft material comprising of soft soil,soft murum ,sand ,hard murum with boulders in wet or dry condition for head works I.e. intake well ,connecting pipe ,jack well, pump house ,supply well etcfor lift 0 to 1.5 m and lead 150 m including barracading ,guarding ,disposing off surplus excavated stuff with in a radius of 0.5 km as directed by engineer - in -charge etc complete excluding refilling b) for head works on nalla or any other site of GSDA for initil ( M.J.P.CSR 2021-2022P.No 44 I No.10 ) Lift0.00 to 1.50 M
88Lift 1.50 to 3.00 M
89Lift 3.00 to 4.50 M
90Lift 4.5 to 6 M
91Lift 6 to 7.5 M
92Item No.3 Excavationin generalinhard material comprisingofsoftrock,hardrock,Manjara rock,etc,byblasting/controlledblasting,chisellingasrequiredinwetordry condition for Head Works i.e. Intake Well, Connecting Pipe, Jack Well, Pump House, supply Well, etc. for lift 0 to 1.5 M and lead of 150 M including baricading, guarding, disposingoffsurplusexcavatedstuffwithinaradiusof0.5km.asdirectedby Engineer-in-charge, excluding refillingLift 7.50 to 9.00 MMJP SSR 2021-22 Item No. 11.a PG. No. 45
93Lift 9.00 to 10.50 M
94Lift 10.50 to 12.00 M
95Lift 12.00 to 13.50 M
96Lift 13.50 to 15.00 M
97Lift 15 to 16.5 M
98Lift 16.5 to 18 M
99Item No.4 Providingandlayingin situ followinggradesofcementconcreteoftrap/ granite/ quartzite /gneiss metal for foundationand bedding including dewatering,form work, compaction, curing, finishing etc. complete.a) M-150 MJP SSR 2021-22 Item No. 2.a PG. No. 49
100Item No.5 Providing and casting in situ c.c. of trap/ granite/ quartzite/ gnesis metal of approved quality for RCC works as per detailed drawings and designs or as directed including normal dewatering,centering,form work, bally, steel propups,compaction,finishing the formed surfaceswith C.M.1:3 of sufficientminimumthicknessto give asmooth andevensurface whereevernecessaryorrougheningif specialis to be provided and curing etc. complete ( By weigh batchingand mix design for M-250 and M-300 only.Use of L&T, A.C.C.Ambuja,BirlaGold, Manikgad,Rajashree,etc. cementis permitted.)( Excluding M.S. reinforcements) RCC M-200 for water retaining structure a) For RingBeam Top Ring
101Bottom Ring
102a) ForVertical Wall (6 m below GL & 1.5 m above GL ) Above 1.5 m from GL
103From GL to Below 5 m
104From 5 to 6 m MJP SSR 2021-22 Item No. 2.d PG. No. 50
105Item No. 6 Providingand fixingin positionsteel bar reinforcementof variousdiametersfor RCC piles, caps, footings, foundations,slabs, beams, columns, canopies, staircase, newels,chajjas,lintels,pardies,copings,fins,arches,etc. as per detailed designs, drawingsandschedulesincludingcutting,bending,hookingthebars,bindingwith wiresor tackweldingand supportingas required,etc.complete.(includingcost of binding wire)1% of RCC Qty Above 1.5 m from GLMJP SSR 2021-22 Revised Item No. 8.b PG. No. 52
106From GL to Below 5 m
107From 5 to 6 m
108Item No.7 Providingstucturalsteelworkin single stanchionscomposedof RSJ, channel,etc, withcaps,bases,mildsteel plates,angles,brackets,cleats,gussetplates,anchor bolts, etc. as per detaileddesign and drawing or as directed by Engineer-in-charge includingcutting,fabrication,hoisting,erecting,fixinginposition,makingriveted/bolted/weldedconnectionsandonecoatsofanticorrosivepaintandoverittwo coats of oil painting, etc. complete. RSJ 200x100mm Weight of RSJMJP SSR 2021-22 Item No. 2.d PG. No. 49
109Item No. 8 Providingand fixing M.S. chequerredplate flooringof following thicknesssupported onM.S.angles(25x25x5 mmsize)includingwelding,cuttingandfabricatingthe plates to the requiredsquare or rounding shape,makingholes in the plate, includingprovidingandapplying3coatsofanticorrosivepaint,etc.completeasdirectedby Engineer-in-charge.6 mm thickMJP SSR 2021-22 Item No. 6.a PG. No. 229
110ITEM NO.9 Dewateringtheexcavatedtrenchesandpoolsofwaterinthe buildingtrenches/ pipeline trenches,well works by using pumps and other devices including disposing offwatertosafedistanceasdirectedbyEngineer-in-charge(includingcostof machinery, labour, fuel), etc. complete.7.5 BHP pumps daily 8 hrs for 45 days MJP SSR 2021-22 Item No. 6.a PG. No. 229
111ITEM NO.10 Providing and fixing in position C.I. dapuri steps for 22 mm dia. M.S. step with proper anchorage,etc.andprovidingandapplying3coatsofant-corrosivepaint,etc complete as directed by Engineer-inchargeMJP SSR 2021-22 Item No.11PG. No. 230
112ITEM NO.11Providing, and fixing 80 mm dia A.C. / P.V.C. pipe weep holes at 1.5 m.c/c staggered including costofallmaterialsandlabourinvolvedwithallleadsandlifts.etc.complete with all leads and liftsMJP SSR 2021-22 Item No.5PG. No. 229
113ITEM NO.12 Refillingthe trencheswith available excavatedstuff with soft material first over pipe lineandthenhardmaterialin15cmlayerswithall consolidation, surcharging etc. complete.MJP SSR 2021-22 Item No. 15PG. No. 45
114ITEM NO.13 Carrying out recuperation/ yield test for asserting the discharge of constructed well/ excavated profile as directed by Engineer-incharge. The test is carried out by drawing down water from the well/profile below normal/ subsoil water level upto full depth rise in water level is recorded. The normal water level/ subsoil water level in the well/ profile as well as stainer/ suction level at pump as per design of W.S. scheme shall be recorded prior to the test including cost of all materials, overhead, labourers, etc. completed as directed.Lps less than 25,000 MJP SSR 2021-22 Item No. 17PG. No. 231
115Switch Room (For pump ) Item No1 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift of 0 to 1.5 M(MJP DSR 20-21, Sr. No. 01, P.No. 42 )
116Item No. 2 Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift of 0 to 1.5 M(MJP DSR 20-21, Sr. No. 02, P.No. 42 )
117Item No.3 Providing and laying in situ Cement concrete M-15of trap or granite or quartzite or gneiss metal for foundation and bedding includingdewatering, form work, compacting,roughening them if special finish is to be provided, finishing if required and curing etcetera complete.PCC (M-150) (MJP DSR 20-21, Sr. No. 01, P.No. 49 )
118Item No.4 Providing and laying in situ Cement concrete of trap/granite/quartzite/ gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc, complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) Excluding M. S. orTor ReinforcementRCC Footings ( M-200)(MJP DSR 20-21, Sr. No. 02/c, P.No. 49 )
119Item No.5 Providing and casting in situ Cement Concrete of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted )RCCCOLUMNS ( M-200)(MJP DSR 20-21, Sr. No. 03/b, P.No. 49 )
120Item No.6 Providing and casting in situ C. C. of trap / granite / quartzite/ gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C. M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever nesessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) RCCBEAMS & lintel( M-200)(MJP DSR 20-21, Sr. No. 04/b, P.No. 50 )
121Item No.7 Providing and casting in situ C. C. of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and desingns or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use ofL&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted .) Slab & Landing steps ( M-200)(MJP DSR 20-21, Sr. No. 06/b, P.No. 51 )
122Item No.8 Providing and casting in situ C. C. of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use fo L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted .) Excluding M S or Tor reinforcement. Chajja ( M-200) (MJP DSR 20-21, Sr. No. 13/b, P.No. 55 )
123Item No. 9 Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar of following proportion superstructure including striking out & racking out joint watering and scafolding etc complete. (PWD SSR 21-22 P.NO.144 I.NO 27.05)
124Item No. 10 Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar of following proportion superstructure including striking out & racking out joint watering and scafolding etc complete. (PWD SSR 21-22 P.NO.144 I.NO 27.05)
125Item No. 11 Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation ,slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire) Tor SteelMJP SSR 21-22 (revised) pg no. 13 Section-A
126Item No.12 Providing and laying Rough Shahabad Stone Flooring 25 mm to 30 mm thick and of required width in plain /diamond pattern on a bed of 1:6 C.M. including cement float ,striking joints ,pointing in cement mortar 1:3 curing and cleaning etc. complete. (PWD SSR 21-22 P.NO.156 I.33.01)
127Item No.13 Providing internal cement plaster 12 mm. thick insingle coat in cement morter 1:5 without neeru finish toto concrete or brick surfaces,in all positions inculding scffolding and curing complete.(Bd-L-5/368) (PWD SSR 21-22 P.NO.153 I.33.05)
128Item No.14 Providing sand faced plasterexternally in cement motar using approved screened sand, in all positions including base coat of 15 mm. thick in cement mortar 1:4 using waterproofing compound at 1 Kg. per cement bag, curing the same fornot less than 2 days and keeping the surface of the base coat rough to recive the sand faced tretment 6 to8 mm. thick in cement mortar 1:4 finishingthe surface by taking out grains and curing for foureen days scaffolding etc. complete. (PWD SSR 21-22 P.NO.153 I.32.11)
129Item No.15 Provinding and applying white-wash in Two coat on old/ new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down complete.(236 Bd-P-1-A)(PWD SSR 21-22 P.NO.218 I.36.02)
130Item No.16 Provinding and applying washable oil-bound distemper of approved colour and shade to old and new surface in two coats including scaffolding preparing the surfaces (excluding the primer coat) etc.complete.(Bd-P-5/413) (PWD SSR 21-22 P.NO.167 I.36.11)
131Item No.17 Providing and fixingsteelframe of angle 50X 50X 6 mm for windows with 16mm with mild steel bar horizantally at 10 cm c/c for ventilator portion and at 15 cm c/c for remaining portion with M.S. flat of size 40x6 mm vertical at center including iron hold fast boxes for fixing 40x6 mm vertical at center including iron .PWD S.S.R. I.No. 1152/39.35P.No. 313 (PWD SSR 21-22 P.NO.182 I.39.33)
132Item No.18 Providing and fixing in position factory made box type steel window with glazed fanlight including steel windows of cold rolled section of 105mm x 60mm x 1.25mm thick frame section filled with cement concrete (1:2:4) and metal pressed steel shutters of 20 gauge (1mm) as per detailed drawing and design or as directed including providing horizontal mild steel 12mm square bars at 10cm center to center, required F7B section, section 76, section 20mm x 5mm mild steel flat for shutter and F4B section for frame, 3mm thick glass of approved quality for fanlight necessary fixtures and fastening etc. complete finishing with one coat of anticorrosive paint etc.complete(PWD SSR 21-22 P.NO.181 I.39.22)
133Item No.19 Providing and fixing steelframe door of angle 50X 50X 6 mm with 16mm with mild steel bar horizantally at 10 cm c/c for ventilator portionincluding iron hold fast boxes for fixing shutters including welding, finishing,painting etc complete.(PWD SSR 21-22 P.NO.182 I.39.35)
134Item No.20Providing and fixing 34 mm thick moulded door shutter consisting of solid core single leaf flush door of 30 mm thickness lipped with 15 mm ( 5mm x 3) thick x 30 mm width on one style and top rail and 10 mm (5mm x 2) thick x 30 mm width on other style and bottom rails. The inner panels laminated with 2 mm thick termite proof, water proof and fire resistant moulded PVC sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 mm plain and /or pre lam PVC on other side using rubber adhesive on flush door and solvent cement adhesive on the PVC lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc. complete. (PWD SSR 21-22 P.NO.186 I.39.48)
135Item No.21 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. (MJP SSR 21-22 P.NO.45 I.15)
136PUMPING MACHINARY 5 BHP ITEM NO. 1 Providing, erecting and giving tests of submersible pump set confirming to IS 8034 and motor confirming to IS 9283, with water proof winding and discharge with stainless steel shaft. Mortar suitable for working on 415 V = 10% 3 phase 50 Hz A.C. supply with cable guard, thrush carbon/fible bearing to withstand entire hydraulic thrust with suitable suction strainer, pump should have suitable discharge outlet as per manufacture\"s design. Antithrust streamlined run and 2 pairs of erection clamps 80 mm width non return valve.Submersible pump 150 mm dia (with bronze impeller upto 8 stages).Submersible pump 150 mm dia (with bronze/ Stainless steel (CF8M) Impeller upto 8 stages).5 BHP suitable for 66 mtr head & 8122 litres/hr discharge. (MJP MECH SSR 21-22 P.NO.1 PM 1-2-5)
137ITEM NO. 2Providing and Fixing L.T. skeleton panel board upto 5 HP. (As per detail sheet attached)
138ITEM NO. 3Supplying and erecting flat flexible 3 core 4 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.(PWD Elect. CSR 2021-22 P. No. 218 I. No. 12-4-9)
139ITEM NO. 4 Providing & erecting ISI mark G.I. pipeof followingclassanddia. including all local and central taxes, octroi, inspection charges, transportation to stores, etc. complete 65 mm dia (heavy) on well(MJP CSR 2021-22 P. No. 82 l. No. 1.III.1.c.vii)
140ITEM NO. 5 Providing, supplying and fixing ISI mark CI D/F Reflux valve (non-return valves of following dia including all taxes (central and local), railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental store/site, unloading, stacking etc. complete. Reflux valves as per I.S. 5312 part I (1984)a) Without bypass arrangement - PN - 1a) Without bypass arrangement - PN - 1 80mm dia(MJP CSR 2021-22 P. No. 131 l. No. 1 a). v)
141ITEM NO. 6 Providing and fixing double flanged sluice valve confirming for IS-2096/14846 including worn gear arrangements as per test pressure stainles steel spindle, caps including all taxes transportation etc completea) Sluice valve - PN - 1(Without bypass).80 mm dia(MJP CSR 2021-22 P. No.132l. No. 2Aiii)
142ITEM NO. 7 Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)a) Sluice valve - PN - 1(Without bypass)80mm dia(MJP CSR 2021-22 P. No.135l. No. 4 v)
143ITEM NO. 8 Providing and erecting pressure gauge of required capacity complete with syphon tube, isolating cock suitable for 12mm dia GI pipe. Pressure gauge shall be installed as directed, with tapping on rising main pressure gauge (100 mm dia)(MJP Mech. CSR 2021-22 P. No.7 PM11-1)
144ITEM NO. 9 Providing earthing with galvanized iron earth plate size 60 x60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP.Plate type Electrode (IS 3043)1. For pump - 2 Nos1. For panel board- 1No.(PWD Elec. CSR 2021-22 Item No. 9-1-3)
145ITEM NO. 10 Providing and supplying ISI standard CI Flanged/ S&S specials including all taxes (Central and local), railway freight, insurance, unloading from railway wagon, loading into truck transport to departmental store/site, unloading stacking etc. complete.CI D/F specialsi) 80 to 300 mm dia(MJP CSR 2021-22 Section-I(I) P. No. 72 l. No. 6ai)
146PUMPING MACHINARY 3 BHP ITEM NO. 1 Providing, erecting and giving tests of submersible pump set confirming to IS 8034 and motor confirming to IS 9283, with water proof winding and discharge with stainless steel shaft. Mortar suitable for working on 415 V = 10% 3 phase 50 Hz A.C. supply with cable guard, thrush carbon/fible bearing to withstand entire hydraulic thrust with suitable suction strainer, pump should have suitable discharge outlet as per manufacture\"s design. Antithrust streamlined run and 2 pairs of erection clamps 80 mm width non return valve.Submersible pump 150 mm dia (with bronze impeller upto 8 stages).Submersible pump 150 mm dia (with bronze/ Stainless steel (CF8M) Impeller upto 8 stages).3 BHP suitable for 34 mtr head & 1590 litres/hr discharge. (MJP MECH SSR 21-22 P.NO.1 PM 1-2-3)
147ITEM NO. 2Providing and Fixing L.T. skeleton panel board upto 3 HP. (As per detail sheet attached)
148ITEM NO. 3Supplying and erecting flat flexible 3 core 2.5 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.(PWD Elect. CSR 2021-22 P. No. 218 I. No. 12-4-9)
149ITEM NO. 4 Providing & erecting ISI mark G.I. pipeof followingclassanddia. including all local and central taxes, octroi, inspection charges, transportation to stores, etc. complete 65 mm dia (heavy) on well(MJP CSR 2021-22 P. No. 82 l. No. 1.III.1.c.vii)
150ITEM NO. 5 Providing, supplying and fixing ISI mark CI D/F Reflux valve (non-return valves of following dia including all taxes (central and local), railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental store/site, unloading, stacking etc. complete. Reflux valves as per I.S. 5312 part I (1984)a) Without bypass arrangement - PN - 1a) Without bypass arrangement - PN - 1 80mm dia(MJP CSR 2021-22 P. No. 131 l. No. 1 a). v)
151ITEM NO. 6 Providing and fixing double flanged sluice valve confirming for IS-2096/14846 including worn gear arrangements as per test pressure stainles steel spindle, caps including all taxes transportation etc completea) Sluice valve - PN - 1(Without bypass).80 mm dia(MJP CSR 2021-22 P. No.132l. No. 2Aiii)
152ITEM NO. 7 Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)a) Sluice valve - PN - 1(Without bypass)80mm dia(MJP CSR 2021-22 P. No.135l. No. 4 v)
153ITEM NO. 8 Providing and erecting pressure gauge of required capacity complete with syphon tube, isolating cock suitable for 12mm dia GI pipe. Pressure gauge shall be installed as directed, with tapping on rising main pressure gauge (100 mm dia)(MJP Mech. CSR 2021-22 P. No.7 PM11-1)
154ITEM NO. 9 Providing earthing with galvanized iron earth plate size 60 x60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP.Plate type Electrode (IS 3043)1. For pump - 2 Nos1. For panel board- 1No.(PWD Elec. CSR 2021-22 Item No. 9-1-3)
155ITEM NO. 10 Providing and supplying ISI standard CI Flanged/ S&S specials including all taxes (Central and local), railway freight, insurance, unloading from railway wagon, loading into truck transport to departmental store/site, unloading stacking etc. complete.CI D/F specialsi) 80 to 300 mm dia(MJP CSR 2021-22 Section-I(I) P. No. 72 l. No. 6ai)
156Rising Main ITEM NO.1 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipessuitable for potable water with solvent cementjoints including cost of couplers, as per ISspecification no. 4985 / 1988 excluding GSTlevied by GOI and GOM in all respect, includingtransportation, freight charges, inspectioncharges, loading, unloading, conveyance to thedepartmental stores and stacking the same inclosed shed duly protected from sun rays andrains including cost of jointing material i.e.solvent cement, etc. complete (selffit type to bejointed with cement solvent). Proposed Percolation Well to junction (90 mm PVC 6 Kg/cm2)Corrigendum No. 7 MJP SSR 2021-2022 (Revised rate Date: - 07/03/2022)
157Junctionto Proposed ESR (90 mm PVC 6 Kg/cm2)
158Junction -1 to Exisitng ESR (90 mm PVC 6 Kg/cm2)
159Providing and supplying ISI standard pvc specials & fittings including transportation to stores/ site,loading,unloadingchargesexcludingGSTleviedby GOI & GOM,etc. complete.10% cost of pipes MJP SSR Section I (II) Page No. 76
160ITEM NO. 2Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints Including all taxes (Central and local) ,InspectionRCC PIPES NP III200 mm dia RCC NP III PIPES(MJP SSR 2021-22 P No.97 section I (V) 1. e iii)
1611% cost of pipes MJP SSR 2021-22 Section I (e) Page No. 97
162Item No.3 Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.Reflux valves as per I.S.5312 Part I (1984)a) Reflux valves - PN -1 Without byepassarrangement 80 mm Dia Reflex Valve (MJP SSR 2021-22 P. No 131 I.No 1a iii to viii)
163Item No.4 Providing erecting ,Connecting double flanged short body pattern type to IS 13095-1991, Sluice valves-PN-1 Sluice valves - PN -1 Without byepassarrangement80 mm Dia(Sluice valve )
164Item No.5 Providing and supplying Air Valves as per IS- 14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in all respect etc. complete. a) Air valve Single ball Flanged - PN -1 32 mm dia (MJP SSR 2021-22 P. No 136 sec. I (XII) 5. a) iv)
165Mechanical Tee 80x80x80 mm (MJP SSR 2021-22 P. No 148 I.No 8/a/1)
166ITEM NO. 6 Labour Section Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift 0 to 1.5MJP DSR 2021-22 SECTION- E Sr.No.1 pg.no.42
167ITEM NO.7 Excavationfor foundation/ pipe trenchesin hard murumand boulders,W.B.M. road includingremovingthe excavatedmaterialupto a distanceof 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatreing, preparing the bed for foundation and excluding backfilling, etc. complete.Lift 0 to 1.5 MMJP DSR 2021-22 SECTION- E Sr.No.2 pg.no.42
168ITEM NO.8 Excavationfor foundation/ pipe trenchesin soft rock&old cement& lime masonary foundation,asphaIt raod includingremoving the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift 0 to 1.5 M MJP DSR 2021-22 SECTION- E Sr.No.5 pg.no.42
169ITEM NO.9 Excavation for foundation / pipe trenches in hard rock by controlled blasting, includingtrimming and levelling the bed by chiselling where necessary and removing theexcavated material and stacking it in measurable heaps within a distance of 50metres from the area and lifts as below, normal dewatering, excluding backfilling, etc.complete. (Bd-A-5/259) Lift 0 to 1.5 MMJP SSR 2021-22 SECTION- E Sr.No.6 pg.no.42
170ITEM NO.10 Filling inplinth floors murum bedding intrenches with approved murum from excavatedmaterialsfromfoundation15to20cmlayersincludingwateringand compaction complete.Murum selected from excavated stuff MJP DSR 2021-22 SECTION- E Sr.No.16 pg.no.45
171ITEM NO. 11 Lowering Laying and jointing with P.V.C pipes and specials of following class and diameter including cost of conveyance from source to site of works including cost of all labour,material,except cement solvent,rubber ring,as per IS code etc.complete (with cement solvent joint/ring fit joint). 90 mm diaMJP SSR Section I (II) Page No. 80
172ITEM NO. 12 Hydraulic testing of PVC pipe line to specified pressure includingcost of all materials and labour and water for testing for specified length including cutting, placing end cap makingarrangement forfillingsafewaterusingreciprocatingtypepumpswhich shouldbeabletoprovidespecified testpressuregaugesandothernecessary equipments,labour,operationcharges,etc. requiredfor testing.The rate underthis itemshallalsoincludecostofretesting,ifnecessaryandreinstatingtooriginal position Working pressure 6 kg/cm2. 110 mm diaMJP SSR Section I (II) Page No. 81
173ITEM NO. 13 Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineerin- charge (For all class of pipes.) as per IS- 783-1985.200 mm RCC Class \"NP-III\" Pipe. (MJP SSR 2021-22 P No.98 section I (V) 2. iv)
174ITEM NO. 14 Lowering, laying, jointing in positionfollowing scour, butterfly valves and sluice valves including cost of all labors jointing material including nutbolts and giving satisfactory hydraulic testing etc complete ( Rates for all class of valves )80 mm Dia(non-return valve ) (MJP SSR 2021-22 P No.135 I.No.4a) iii, iv)
17580 mm Dia(Sluice valve )
176ITEM NO. 15 Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete, 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M 150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve tee, etc. complete as per type design and as directed by Engineer -in- charge for following diameters of pipe lines (type design attached)Upto 150mm 32 mm dia
177ITEM NO. 16 Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion,precast RCC frame and cover, etc. Complete as directed by engineer-in-charge. Note: Wall thickness : 0.23 M for depth of .2 M and 0.35 M for balance depth exceeding 1.2 M. As above of 60x45 CM internal size and depth upto 0.9 M with precast R.C.C slab cover(MJP SSR 2021-22 P No.220 I.No.1a)
178ITEM NO. 17 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.(MJP SSR 2021-22 P No.45 I.No.15)
179RCC ESR 29000 litres Staging Height 12 m. ITEM NO.1 Designing (aesthetically), and constructing RCC Elevated Service Reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 meters centre to centre for E.S.R. having capacity 500 m3 & not more than 6 m c/cfor E.S.R.having capacity above 500 m3 including excavation in all types of strata, foundation concret, cement plaster with water proofing compound to the inside face of the container including refilling disposing of the surplus stuff within a lead of 50 meters, all labour and material chargesincluding lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design. providing and fixing accessories such as Stainless steel ladder inside and M.S. ladder with G.I. railingoutside, C. I. manhole frame and covers water level indicatiors, lightening conductor, G. I. pipe railing around walk way and top slab, providing spiral staire case from ground level to roof level, M.S.Grill gate of 2 Mtrs height with locking arrangement, B.B. masonry chambers for all valves, ventilating shafts, providing and applying three coats of acrylic emulsion with silicon additives paint to the structure including roof slab and epoxy paint to internal surface & anti-termite treatment for underground parts of the structures and giving satisfactory water tightness test as per I.S. code, The job to include painting the name of the scheme and other details on the reservoir as per the directions of Engineer-in-charge.The design of the structure be in accordance with relevant I.S. specification (I.S. 3370 - 1965 or revised.) The design shall satisfy the stipulations as per I.S. 1893 - 1984 and I.S. 13920 / 1993 for seismic force and I.S. - 11682 / 1985 for R.C.C. staging of overhead tanks.For design having more than 6 columns, provision of internal bracing is obligatory.Externalbracingsisalso obligatory.The entire structure shall be in M-300 mix only.Plainroundmildsteelbarsgrade-I conformingtoI.S.432part-I or high yield strength deformed bars conformingtoI.S.1786orI.S.1139 shall be used, grade-II mild steel bars will not be allowed.Irrespective of the type of foundation proposed in the design, one set of bracing be provided at the ground level.These rates include providing M.S. ladder for E.S.R.s upto 2 lakh litres capacity and providing spiral staircase for E.S.R. above 2 lakh litres capacity.Staging shall have to be designed with stresses of M-200 concrete for ESR. Howeverall RCCconstructionshould be done in M-300.Theseratesare includingthe costof uplift pressure if any and entire dewatering during execution. In case of waterloggingareawherewateris stretch at shallow depth, extra provision of dewatering shall be made as per site condition.AllconditionsgivenintheMember Secretary\"sCircularNo. MJP/ TS-I/ 350 / 1668 dt. 2-8-97 and MJP / S-I / 350 / 2127 dt. 13-7-99 shall be strictly followed andadditional cost, if any, due to these conditionsis includedin the rates mentioned below.75%partrateshallbepayablefor reinforcementconcreteand plastering items of containers of E.S.R. till satisfactoryhydraulictesting for water tightnessisgiven;andtillthatwork shall be treated as incomplete.Theratesindicatedinthetableare excludingthecostofpipes,specials andvalvesrequiredforinlet,outlet, washout, overflow and bypass arrangement. The scope of work, however, includes costoferecting, laying and jointing of pipes and valves including cost of jointing materials upto 5Mbeyondouterfaceof outermost column.ForESRupto500cumcapacityC.I. double flanged pipes upto 300 mm dia shall be provided and C.I. specials shall beused.ForESRabove500cum capacityC.I./M.S.pipeassemblywith minimum 8 mm thickness upto 500 mm diaandminimum10mmthickness above 500 mm dia can be used with properanti-corrosiveepoxy treatment from inside and outside.Belowmentionedratesarefor foundations with individual footing with bearing capacity of20tonnes per squaremetre.Forraft foundations, these rates shall be increased by 7.5% where safe bearing capacity (SBC) is 5 MT per sqm and by 5% where SBC is morethan5 MT/sqmandupto10 MT/sqm.This%of5%or 7.5%is applicable for estimationof amount of lumpsumitem of ESR. For extra item due to change from individual foundationtoraft, actualincreasein concreteandsteelbepaidasper relevant DSR item.The rate shall be increased by 30% for bearing piles upto depth of 10 M and for further increased in depth by 5 M each, it shall be increasedby another10%. These rates are applicable where raft is not feasible. For pile foundations sulphate resistant cement shall only be used. Single pile for the column is not permitted, group of piles shall be designed with pile cap for each column of ESR.The rates are applicable for staging heightof 12 M. Theseratesshallbe increasedor decreasedfor per metre variation in this staging height as below:Following rates are for seismic zone III. For zone IV, these rates shall be increased by 5% and for zone II, these rates shall be decreased by 5%. Concerned Executive Engineer shall confirm the seismic zone for the scheme from seismic zones plan before estimation and adopt appropriate rates as per actual seismic zones. (Seismic maps attached in this CSR).RCC ESR Capacity 29000 litres 12 m staging Height, 3 m tank height. Total cost for 29000 Litres @ 12 m staging Height . 5% decrease for zone II(MJP SSR P No. 214 Section K (II)2.)
180ITEM NO.2 Providing & supplying ISI standard CI double flanged pipes excluding GST levied by GOI & GOM in all respect including railway freight, insurance , unloading from railway wagon, loading into truck transport to stores, unloading etc. complete as directed by Engineer-in-charge. (MJP SSR P No. 72 Section I(I)5.ii/iv) Inlet 80 mm dia CID/F pipes
181Outlet 100 mm dia. CI.D/F pipes
182Overflow 80 mm dia. CI.D./F pipes
183Washout 80 mm dia. CI.D/F pipes
184ITEM NO.3 Providing And supplying ISI standard CI Flanged /s &S Specials Including all Statutory Duties &taxes such as GST Levied by GOI &GOM in all Respect.Railway Freight Insurance Unloading From Railway wagon,Loading into truck Transport to Departmental Store /Site UnloadingStacking etc Complete D/F Specials 300 D/F Specials Upto and Including150 mm. 80 mm to 300 mm dia. ( M.J.P SOR 21-22P.NO 72 I.NO.6a)
185ITEM NO.4 Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. complete. Sluice valves PN-1 without bye-pass arrangement (MJP SSR P No. 132 Section I(XII) 2a.iv) 100 mm dia. Sluice valve - Outlet/Distribution
18680 mm dia. Sluice valve - Inlet/Bypass
18780 mm dia. Sluice valve - Washout
188Distribution System ITEM NO.1 Material. Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same inclosed shed duly protected from sun rays and rains including cost of jointing material i.e.solvent cement, etc. complete (self fit type to be jointed with cement solvent).MJP SSR 2021-22 Section I (II) Page No. 76 Working Pressure 4 kg/cm2 75 mm
18990 MM
190110MM
191Providing and supplying ISI standard PVC & GI specials and fittings including transportation to stores/site, loading, unloading charges excluding GST levied by GOI & GOM, etc. complete.10% of cost of pipes
192ITEM NO.2Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints Including all taxes (Central and local) ,Inspection RCC PIPES NP III Considering Nalla / Road Crossing 200mm dia RCC NP III PIPES
1931% of cost of pipes
194ITEM NO.3 Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. complete.Without by pass arrangement - PN-1.MJP DSR 2021-22 SECTION- E Sr.No.2 pg.no.42. 65 mm sluice valve
195ITEM NO.4 LABOUR Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling,wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering,excluding backfilling, etc. complete by allmeans. (Bd-A-6/259)Lift 0 to 1.5MJP DSR 2021-22 Section E Sr.No.2 Pg. No.42
196ITEM NO.5Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation andexcluding backfilling, etc. complete. (Bd-A 1/259) Lift 0 to 1.5MJP SSR 2021-22 Section E Sr.No.2 Pg. No.42
197ITEM NO.6 Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundationand excluding backfilling, etc. complete. (Bd A-2/259)Lift 0 to 1.5MJP DSR 2021-22 Section E Sr.No.2 Pg. No.42
198ITEM NO.7 Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd A-3/259.Lift 0 to 1.5 MJP DSR 2021-22 Section E Sr.No.2 Pg. No.42
199ITEM NO.8 Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259 Lift 0 to 1.5MJP DSR 2021-22 Section E Sr.No.2 Pg. No.42
200ITEM NO.9 Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15cm to 20cm layers including watering and compaction complete.Murum selected from excavated stuffMJP DSR 2021-22 Section E Sr.No.16 Pg.No.45
201ITEM NO.10 Lowering Laying and jointing with P.V.C pipes and specials of following class and9 diameter including cost of conveyance from source to site of works including cost of all labour,material,except cement solvent,rubber ring,as per IS code etc.complete (with cement solvent joint/ring fit joint) Working Pressure 4 kg/cm2MJP DSR 2021-22 Section I(II) Sr.No.4 Pg. No.80 75 mm
20290 mm
203110 mm
204ITEM NO.11 Hydraulic testing of PVC pipe line tospecified pressure including cost of allmaterials and labour and water for testing forspecified length including cutting, placing endcap making arrangement for filling safe waterusing reciprocating type pumps which shouldbe able to provide specified test pressuregauges and other necessary equipments,labour, operation charges, etc. required fortesting. The rate under this item shall alsoinclude cost of retesting, if necessary andreinstating to original position. MJP SSR Section I(II) Pg. no. 80 Working Pressure 4 kg/cm2 75 mm
20590 mm
206110 mm
207ITEM NO.12 Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineerin- charge (For all class of pipes.) as per IS- 783-1985.Considering Nalla / Road Crossing. 200 mm RCC Class \"NP-III\" Pipe.MJP SSR 2021-22 Section 2 Page No. 98
208ITEM NO.13 Lowering, laying, jointing in positionfollowing CI/DF Reflux, butterfly valves and sluice valves including cost of all labors jointing material including nutbolts and giving satisfactory hydraulic testing etc complete ( Rates for all class of valves ) MJP DSR 2021-22 Item No. 4a Sec. I (XII)pg.no.135 65 mm sluice valve
209ITEM NO.14 Providing and fixing C.I. road box including loading, unloading and carting to site of work including all necessary excavation in all types of strata and fixing in murum packing, etc. complete. 100 mm x 225 mm (20 kg). MJP DSR 2021-22 Item No. 5a pg.no.223
210ITEM NO.15 Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)Spec. No. - Bd E /1 Page No. 287 and B-7, Page No. 38
211ITEM NO.16 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. Net volume of refilling. MJP DSR 2021-22 Item No. 16 Sec.E pg.no.45
212CHLORINATION ARRANGEMENT ITEM NO.1 Providing and installing simplegravityfeed disinfection arrangement with TCL powder solution on the percolation well / service reservoir including solution tankfeeding pipe, dosing arrangement all other accessories giving tgrialand test etc. complete. Drip Type Chlorinator 2 set
213TRIAL & RUN OF SCHEME ITEM NO.1 Commisioning running and maintaining the scheme to quantities, rate capacity, including manning necessory personnel such as operator, valveman, etc, as pr requirements of the scheme and who should also administer chemical dose for a period of one month for individual scheme together with training of personnel spared by MJP/ Local Body and handling over the scheme to Local Body after completion of the above period as directed by Engineer - in charge. For single village (1 Month) (M.J.P. SOR 21-22 P. No 232 I.No.1a)
214Fencing and M.S. gateFor Ex. Well ITEM NO.1 Providing & erecting chain link fencing 1.6 Mtr height with GI chain link of size 50*50 mm 8 SWG thick and fixed 75 mm above GL vertical M.S. angle of 40*40*6 mm size embedded in cc block 1 :4 :8 mix of size 450*450*670 mm at 1.75 m centre to centre wiyh iron bar 16 mm dia as a hold fast including welded link with angle frame at 30 cm cenre to centre nuts & bolts & horizontal MS angle at top & bottom of 25 * 25* 5 mm size & vertical MS flat 35 * 5 mm & 25 * 5 mm horizontal including cross supports of 40 *40*6 mm angle both sides at every corner in cc with 3 coat of oil painting etc complete. PWD SSR 2021-22 I.No 46.39 BDW P.No.217
215ITEM NO.2 Providing and fixing M.S. gate 2.5 Mwide for compound with 40 mm dia G.I.pipe, approved grill work, RCC M-150 sidepillars of 25 cm x 40 cm x 2.5 M height, itsfoundation, finishing, painting, etc.complete.MJP SSR Section-H: Miscellaneous P.No.58
216Fencing and M.S. gate For Proposed Percolation Well ITEM NO.1 Providing & erecting chain link fencing 1.6 Mtr height with GI chain link of size 50*50 mm 8 SWG thick and fixed 75 mm above GL vertical M.S. angle of 40*40*6 mm size embedded in cc block 1 :4 :8 mix of size 450*450*670 mm at 1.75 m centre to centre wiyh iron bar 16 mm dia as a hold fast including welded link with angle frame at 30 cm cenre to centre nuts & bolts & horizontal MS angle at top & bottom of 25 * 25* 5 mm size & vertical MS flat 35 * 5 mm & 25 * 5 mm horizontal including cross supports of 40 *40*6 mm angle both sides at every corner in cc with 3 coat of oil painting etc complete. PWD SSR 2021-22 I.No 46.39 BDW P.No.217
217ITEM NO.2 Providing and fixing M.S. gate 2.5 Mwide for compound with 40 mm dia G.I.pipe, approved grill work, RCC M-150 sidepillars of 25 cm x 40 cm x 2.5 M height, itsfoundation, finishing, painting, etc.complete.MJP SSR Section-H: Miscellaneous P.No.58
218ITEM NO.3 Providing and fixing board displaying information, such as \"Name of work, Tender cost, Name of Contractor, work completion and liability period etc\", having rectangular shape of 1.20m * 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coats of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border/ messages / symbols etc. with approved colour shade paint complete, on M.S,angle of size 35 * 35 *3 mm frame with properly cross braced M.S. angles of size 35mm*35mm*3mm duly painted including Two M.S. angle iron posts of size 65 mm * 65 mm *6 mm, 3.65m long painted with alternate black and white bands of 25 cm width including all fixtures etc. and fixing the boards in 1:4:8 concrete block of size 60 cm *60 cm *75 cm including, excavtion, refilling, transportation and labour etc complete. Spec. No. As directed by Engineer in Charge SSR I.No. 6.96
219FHTC ITEM NO. 1 Providing and making UPVC/MDPE pipe consumer service connection on Distribution main by drilling hole with suitable means , including all labour , UPVC/MDPE Pipe of required length with or without Road crossing as described below, including cost of specials like Saddle/Clamp Saddle of suitable material, and diameter suitable for Distribution main, 15mm /20mm/ 25mm respective Dia Heavy duty Brass/Polyprophylyne(Twin Jacketed ) Ferrule , Male and Female thread adapter Elbow, Bends,couplers ,Tees, Clamps of suitable material and sundry materials as per requirment, including providing and fixing medium duty 15.mm brass bib tap, GI casing pipe of suitable diameter of 32mm/ 40mm/ 50mm respectively of required length for Road crossing, including requird labour for excavation in all types of strata up to the depth of 0.75m or as per site requirement,all types of plumbing fittings, refilling , Closing the water supply in that area, dewatering, hydraulic testing and restarting the water supply ,transportation of material etc. complete as directed by Engineer in A) Household Connection without water meter (Comression Saddle+ISI Mark Ferrul) for HDPE & PVC pipe For MDPE/UPVC Pipe Service Connection on Disribution main (With Road Crossing)For 15 mm Service connection
220Without Road Crossing)For 15 mm Service connection

AI Tender Summary

OUR REF NO 32848750
AUTHORITY Government Departments
TENDER VALUE 1.12 Crore
LAST DATE 11-07-2022
Authority
Authority Name Rural Development Department
Work Description Retrofitting Of Water Supply Scheme At Borkhadi Pingle Borkhadi Tanda Tq. Sengaon Dist. Hingoli Under Jal Jeevan Mission ( Jjm )
Basic Detail
Tender No Open/RWS/EE/jaljivan/09/22-23
Bidding Type Tender
Location
City tanda
State Maharashtra
Key Dates
Publish Date 27 Jun 2022
Submission Date 11 Jul 2022
Open Date 13 Jul 2022
Finance
Tender Value 1.12 Crore
Tender Fee 5600
EMD 1.12 Lakhs
Exemption Not Available
Document List
f7f5e886-0ec0-4b6d-b71e-44bce121243c.html
B1Document.pdf
BOQ_1400613.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 27, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 11, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 13, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

f7f5e886-0ec0-4b6d-b71e-44bce121243c.html

pdf

B1Document.pdf

xls

BOQ_1400613.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders